                                      TENDERNOTICE
  Sealed bids are invited for supply of following equipments and mechanical erection work
  from reputed manufacturers / suppliers/Contractors having sound, technical, financial
  capabilities under Centrally sponsored Scheme
  Sl.No. Name of Equipment / Mechanical works                      Qty        Tender
                                                                  Nos         fee (Rs.)
  1        Mechanical erection works for expansion at                1 lot    1000
           Kasaragod Dairy, Products Dairy, Kozhikode &
           Milk Chilling Plant Pattambi. PAC Rs.40 lakhs
  2        Refrigeration Plant supply & erection at Milk               LS     500
           chilling Plant, Pattambi.PAC . Rs.20 lakhs
  3        Cold store at Palakkad and Kasaragod Dairy .PAC.            LS     500
           Rs.23 lakhs
  4        Pouch Filling Machines (Re tender)                            4    500
  5        Steam Boiler 1 tonne per Hr.(Re tender)                       1    100
  6        SS Pipes, valves& fittings 63 mm,51mm with unions         1 lot    100
  7        Deep Freezers 500 L                                         20     100
  8        Digital Camera                                                2    100
  9.       Ink jet coding device                                         2    100

  Separate tender forms can be had from this office from 27.10.2008 to 17.11.2008.on
  payment of tender fee in cash/DD in favor of MD, MRCMPU Ltd payable at Kozhikode
  plus Rs.50/- extra if sent by courier / post. Last date for receipt of Tender 18.11.2008.
  Tender will be opened on the same day. The details available in the MILMA web site,
  www.milma.com.



                                                           MANAGING DIRECTOR
        1.TENDER FOR MECHANICAL WORKS AT KASARGOD DAIRY,
        PRODUCTS DAIRY and MCP, PATTAMBI UNDER IDDP
                              KASARAGOD DAIRY, ANANDASHRAM ,KANHANGAD

        The following works are to be executed for the new Curd / Sambaram manufacturing plant at Kasaragod
        Dairy, Kanhangad. The plant is located just behind the existing Dairy Plant. The new Plant is connected with
        the existing plant with a concrete corridor for the movement of men, materials and Products. Products line
        between the plant are to be run through the corridor.
         The new curd plant will have a Production capacity of 5000 Liter per batch for curd and Sambaram. Erection,
        testing and commissioning of all equipment proposed in the new plant including service line and product line
        are included in the scope of mechanical erection.(The tanks are unloaded in the first floor in position. the
        Contractor has to align and level the tanks for interconnection of SS pipelines, Service line etc.)
                                                   Schedule of Works


   LIST OF EQUIPMENTS TO BE ERECTED & COMMISSIONED BY THE CONTRACTOR AS PER
                                 SPECIFICATION
                                                                                       RATE         AMOUNT
SL No    ITEM DESCRIPTION                                                     UNIT QTY (Rs.)        (Rs.)
A
        1 Horizontal milk storage tank , 5000 L for curd and sambharam        No        3
         Curd pasteuriser with milk pump , hot water mixing tank and pump
        2 , steam controller etc                                              set       1
        3 Hooper with ventury (RCM) , 5000 L capacity with milk pump          set       1
         Pouch filling machine 5000 PPH(shifting and erection from existing
        4 plant)                                                              No        2
        5 Plate chiller for sambharam chilling 5000 LPH                       set       1
        6 Reconstitution tank 2000L                                           No        1
         Cooling tower 50TR of Paharpur make (To be erected in the
        7 second floor)                                                       set       1
        8 Cooling tower water pump 5HP                                        No        1
        9 Milk pumps 5000 LPH                                                 No        2
       SS Pipes and fittings for the Cream line
    10 51 mm SS Pipe                                                          Mtrs   240
    11 38 mm SS pipes                                                         Mtrs     6
                                                            68
         All SS material will be supplied by the client .MS materials used for
         supports will be paid separately in kg under separate item .
         Erection of SS pipeline will include erection of SS ground /ceiling
         supports with SS clamps, fixing of 15 mm SS nipples, SS 2/3 way
         valves, in line filters , SS unions , bends , dummies. Etc. The
         pipelines are to be expanded using expanding tool with guide for
         fixing to unions . TIG welding shall be employed wherever required
         as directed by the engineer . The measurement shall be taken in
         meter including the valves and fittings
        LIST OF EQUIPMENTS TO BE SUPPLIED , ERECTED & COMMISSIONED BY THE
                        CONTRACTOR AS PER SPECIFICATION


          Supply and laying of GI B Class pipes (rate shall be inclusive
          of same quality bends, tees, reducers, and MS flanges as per
          BS 10 TABLE D gaskets , bolts, nuts, etc. wherever necessary)
B         conforming IS.1239.
        1 NB80mm                                                         M             24
        2 NB65 mm                                                        M             100
        3 NB50 mm                                                        M             170
        4 NB40 mm                                                        M             60
        5 NB25 mm                                                        M             18
        6 NB15 mm                                                        M             36
         Supply and erection of Butter fly valve with flange , Audco
C        make or eqv.
        1 NB80 mm                                                                no     1
        2 NB50 mm                                                                no     8


         Supply and erection of Ball valve screwed , audco make or
D         eqv. with SS working part
        1 NB25 mm                                                                no     2
        2 NB15 mm                                                                no     6
           Supply and erection of GM Non return valve vertical type ,
E         screwed with SS working part
          NB50 mm                                                                no.    3
           Supply and erection of Water meter ANAND ZENNER /KENT
    F     with accessories like filter , flanges etc
        1 NB 80 mm                                                               no.    1
          Supply and erection of Brass float valve for cooling tower
G         make up
        1 NB25 mm                                                                no.    1
         Supply and erection of Cold Insulation of Chilled water lines
          with thermocoal pipe sections HD (50mm thick), fixed and
          sealed using 80/100 bitumen including cladding with(24SWG)
          aluminium sheet and self threading GI screws for the
H         following pipe lines.
        1 NB65 mm                                                    Mtrs      84
        2 NB 50 mm                                                   Mtrs      12



I        MS Pipes and Fittings for steam line
         Supply and laying of MS pipes Class "C" (Heavy) 'ERW' quality
         as per IS 1239 (Rate should be inclusive of same quality
         bends, tees, reducers, MS flanges as per BS table F gaskets,
         bolts, nuts, etc. whenever necessary
        1 NB 50 mm                                                     M       60
        2 NB 40 mm                                                     M       15
        3 NB 25 mm                                                     M       10
        4 NB15 mm                                                      M       80

          Supply and erection of Audco make Globe valve
         screwed end, GM body and SS working parts with
          vergin PTFE to withstand 200 degree centigrade
J              temp.and 5kg/sq.cm pre.for steam line
        1 NB 50 mm                                                       no     1
        2 NB 40 mm                                                       no     6
        3 NB25 mm                                                        no     1
        4 NB15 mm                                                        no    12
         Supply and erection of Steam trap bucket type spirax make or
K        eqv.
        1 NB15mm                                                         no    4

L          Supply and erection of Steam and water mixing
    1                         battery                                    no.   7
         (steam and water mixing battery consisting of U shaped
         mixing unit fabricated out of 15NB C class GI pipe , 2 nos 15
         mm NB steam valves of GM body and SS working parts with
         flanges, 2 nos Vertical type NRV ,GM body and SS working
         part,)
         Thermal Insulation of steam lines with resin bonded mineral
         wool (50mm thick), 40 g chicken wire mesh including cladding
         with(24SWG) aluminium sheet an self threading GI screws for
M        the following pipe lines.
        1 NB 50 mm                                                       M     60
        2 NB 40 mm                                                       M     15
        3 NB 25 mm                                                       M     10
        4 NB15 mm                                                        M     80
         Supply,Fabrication and erection of MS Platform for Pouch
         filling machine , cooling tower in the new plant by using
N        MS/Aluminium chequred plate
         MS Platform for ghee vat 4 Nos MS Ladder etc. with
         necessary stiffeners and GI 'A' Class Pipe as railing with
         channel, plates, angles, etc. as required
        1 M.S Channel/angles/Flat etc.                                          Kg     1000
        2 GI 'B' Class 20mmPipe                                                 Mtrs   100
        3 Chequred plate MS 6mm thick                                           Kg     250
        4 Chequred plate Alu. 5mm thick                                         Kg     100


Note:

Fabrication of platform , bridges etc. shall be carried out in consultation with Engineer in charge and Dairy Manager
Manager Chilling Plant as per the site condition.


                                 PRODUCTS DAIRY , NADUVATTOM

The woks as per the tender has to carry out for a new Ghee Production constructed under IDDP Scheme. All
the ghee production equipment will have to be positioned in the first floor .Ghee filling will be done in the
ground floor. The milk/cream brought from the main Dairy will be pumped from the ground floor to first
floor.

 The scope of work is inclusive of dismantling, shifting, erection and commissioning of existing ghee
production equipments and pipelines and erection, testing and commissioning of new equipments available at
site. All the required service lines are to be supplied and erected by the contractor

                                          SCHEDULE OF WORKS

     LIST OF EQUIPMENTS TO BE ERECTED & COMMISSIONED BY THE CONTRACTOR AS PER
                                   SPECIFICATION
                                                                                     QT RATE           AMOUNT
 SL No ITEM DESCRIPTION                                                         UNIT Y  (Rs.)          (Rs.)
 A              Dismandling, shifting Erection,and Commissioning
      1 Cream pump of Capacity 5KLPH                                            No        1
      2 Cream pump of capacity 2 KLPH                                           No        3
      4 Ghee melting valt of Capacity ( 2 KL) including all fittings            No        2
      5 Settling tank of capacity (1.5 KL) including all fittings               No        2
      6 Settling tank of capacity (2 KL) including all fittings                 No        2
      7 Ghee storage tank capacity (2 KL) including all fittings.               No        1
      8 Ghee storage tank capacity (1.5 KL) including all fittings valve etc.   No        1
      9 Cream storage tank capacity (2KL) including all valve and fittings    No          3
    10 Ghee clarifier capacity 1000 LPH                                       No          2
    11 Balance tank 200 L capacity                                            No          2
B       Erection, commissioning & testing of new equipments
       Ghee melting valt of Capacity (2KL) with all fittings including
     1 valves etc.                                                            Nos         2
     2 Ghee storage tank ( 5 KL) with all valves, fittings etc.               Nos         1
     3 Cream storage tank (2 KL) with all valves and fittings                 Nos         1



LIST OF EQUIPMENTS TO BE ERECTED & COMMISSIONED BY THE CONTRACTOR AS PER
SPECIFICATION
                                                                                     RATE AMOUNT
SL No ITEM DESCRIPTION                                                       UNIT QTY (Rs.) (Rs.)
A     SS Pipes and fittings for the Cream / Milk line
     1 51 mm SS Pipe                                                         Mtrs   100
     2 38 mm SS Pipe                                                         Mtrs    30
     3 Dismantling the SS Pipes from existing plant                          Mtrs    50

      All SS material will be supplied by the client .MS materials used
      for supports will be paid separately in kg under separate item.
      Erection of SS pipeline will include erection of SS ground /ceiling
      supports with SS clamps, fixing of 15 mm SS nipples, SS 2/3 way
      valves, in line filters, SS unions, bends, dummies. Etc. The
      pipelines are to be expanded using expanding tool with guide for
      fixing to unions. TIG welding shall be employed wherever required
      as directed by the engineer. The measurement for pipes shall be
      inclusive of valves and fittings and will be measured in running
      meter basis




      Supply and laying GI B Class pipes for water distribution line
      (rate should be inclusive of same quality bends, tees, reducers,
      and MS flanges as per BS 10 TABLE D gaskets, bolts, nuts, etc.
B     wherever necessary) conforming IS. 1239

     1 NB 80 mm                                                              Mtrs    40
     2 NB 50mm                                                               Mtrs   100
     3 NB 25 mm B Class (For water point)                                    Mtrs    50
     4 NB15 mm B Class (For water point)                                   Mtrs    50

       Supply and erection of Butter fly valve with flange , Audco
       make or eqv.
     1 NB80 mm                                                             Nos      3
     2 NB50 mm                                                             Nos      3


       Supply and erection of Ball valves of AUDCO make screwed
       end with SS moving part, seal virgin PTFE, Lever operated

     1 NB 25 mm                                                            Nos     8
     2 NB 20 mm                                                            Nos    16

       Supply and erection of Water meter ANAND ZENNER /KENT
       with accessories like filter , flanges etc
     1 NB 80 mm                                                            No       1




C      MS Pipes and Fittings for steam line

       Supply and laying of MS pipes Class "C" (Heavy) 'ERW'
        quality as per IS 1239 (Rate should be inclusive of same quality
        bends, tees, reducers, MS flanges as per BS table F gaskets,
      1 bolts, nuts, etc. whenever necessary (approximate)
    1.1 NB 50 mm                                                           Mtrs   170
    1.2 NB 40 mm                                                           Mtrs    20
    1.3 NB 25 mm                                                           Mtrs    60
    1.4 NB 20 mm                                                           Mtrs    20


        Supply and erection of Steam valves flanged with counter
        flanges, AUDCO make with SS moving part, seal virgin PTFE,
        Lever operated , Body : ASTM A 216 Gr.
      2 WCB/ASTM A105.
    2.1 NB 50 mm                                                   Nos             3
    2.2 NB 25 mm                                                   Nos            30
         Thermal Insulation of steam lines with resin bonded mineral
         wool (50mm thick), 40 g chicken wire mesh including cladding
   D     with 0.83 mm (22SWG) SS sheet for the following pipe lines.
       1 NB 50 mm                                                     Mtrs              170
       2 NB 40 mm                                                     Mtrs               20
       2 NB 25 mm                                                     Mtrs               60
       2 NB 15 mm                                                     Mtrs               20


        Supply,Fabrication and erection of MS Platform for Ghee Vat
        by using 6 mm thickness MS / Alu./SS chequred plate MS
        Ladder etc. with necessary stiffeners and GI 'B' Class
        20mmPipe as railing with channel, plates, angles, etc. as
  E required
      1 M.S Channel/angles/Flat etc.                                Kg   2000
      2 GI 'B' Class 20mmPipe                                       Mtrs 200
      3 Chequred plate MS 6mm thick                                 Kg   1000
      4 Chequred plate Alu. 5mm thick                               Kg    100
      5 Chequred plate SS 4mm thick                                 Kg    100
 Note:
        Fabrication of platform , bridges etc. shall be carried out in
        consultation with Engineer in charge and Dairy Manager / Manager
        Chilling Plant as per the site condition.

                                 MILK CHILLING PLANT , PATTAMBY
Existing milk Chilling Plant ,Pattambi has 3 numbers of Milk coolers .These BMCs are to be shifted to new
locations. New Refrigeration Plant with IBT and Compressors are to be positioned in the plant.This is being
carried out under a separate Contractor. Scope work as per this tender is including of the following:

1.Dismanteling of existing bulk milk coolers 5KL capacity 3 numbers with condensing unit ,
stebilizer,pipelines and
  accessories from the first floor of the building and stacking safely in the campus as per the direction of the
Engineer.

2.Shifting,erection and commissioning of 2 numbers of 10KL capacity Horizontal milk storage Tanks in the
first floor.

3.Erection of Milk Chiller 5KL capacity with necessary pipes, valves and fitting supports etc.
44.Service pipeline as required.
                                           SCHEDULE OF WORKS

          LIST OF EQUIPMENTS / ITEMS SUPPLIED BY THE CLIENT TO BE ERECTED,TESTED AND
                                COMMISSIONED BY THE CONTRACTOR

                                                                                        RATE    AMOUNT
SL No ITEM DESCRIPTION                                                         UNIT QTY (Rs.)   (Rs.)
A       1 Horizontal milk storage tank , 10 KL                                   Num     2
         2 Plate chiller 5000 LPH with pipes and fittings                        set     1
         3 Milk pumps 5000 LPH                                                   Num.    2
         4 Fabrication, erection , testing of raw water line                     Mtr.   50
         5 SS Pipes and fittings for chiller ,Dump tank and HMST
         6 51 mm SS Pipe                                                         Mtr.   100
           All SS material will be supplied by the client .MS materials used for
           supports will be paid separately in kg under separate item . Erection
           of SS pipeline will include erection of SS ground /ceiling supports
           with SS clamps, fixing of 15 mm SS nipples,SS 2/3 way valves, in
           line filters , SS unions , bends , dummies. Etc. The pipelines are to
           be expanded using expanding tool with guide for fixing to unions .
           TIG welding shall be employed wherever required as directed by the
           engineer . The measurement shall be taken in meter including the
           valves and fittings
           Supply and laying of GI B Class pipes (rate shall be inclusive of
           same quality bends, tees, reducers, and MS flanges as per BS 10
           TABLE D gaskets ,bolts, nuts, etc. wherever necessary)
B          conforming IS.1239.
         1 NB 65 mm                                                              M       20
         2 NB 50 mm                                                              M       30
         3 NB 25mm                                                               M       50
         4 NB 20mm                                                               M       20
        .5 NB 15 mm                                                              M       30

          Supply and erection of Butter fly valve with flange , Audco
    C     make or eqv.for water lines
        1 NB 65 mm                                                             no        3
        2 NB 50 mm                                                             no        4
          Supply and erection of Ball valve screwed , audco make or eqv.
    D     with SS working part
        1 NB 25 mm                                                             no        6
          NB 20 mm                                                             no        6
        2 NB 15mm                                                              no        6
           Supply and erection of GM Non return valve vertical type ,
E         screwed with SS working part
          1 NB 50 mm                                                          no.      2
            Supply and erection of Water meter ANAND ZENNER /KENT
  F        with accessories like filter , flanges etc
          1 NB 65 mm                                                          no.      1
            Supply ,Fabrication and erection of MS Platform by using
            MS/Aluminium chequred plate , MS Ladder etc. with necessary
            stiffeners and GI 'A' Class Pipe as railing with channel, plates,
  G         angles, etc. as required
          1 M.S Channel/angles/Flat etc.                                      Kg     500
          2 GI 'B' Class 20mmPipe                                             Mtrs   100
          3 Chequrred Plete MS 6mm thick                                      Kg     100
  Note:
           Fabrication of platform , bridges etc. shall be carried out in
           consultation with Engineer in charge and Dairy Manager / Manager
           Chilling Plant as per the site condition.


SUPPLY & INSTALLATION OF REFRIGERATION SYSTEM
AT MILK CHILLING PLANT,PATTAMBI
1.Functional Requirements:

  MRCMPU wants to set up a refrigeration plant at the existing milk chilling plant, Pattambi
in Palakkad District with the available old Ammonia refrigeration equipments shifted from the
Milk Chilling Plant,Meenagady, Wayanad District. The list of available equipments and list
of equipment to be supplied by the contractor included are listed below separately .The
scope of work is inclusive of erection testing and commissioning of the total refrigeration
plant consisting of 2 nos 6”X6” ammonia compressors with IBT system condensors etc as
detailed below . The refrigeration plant is intended to operate 8 hrs in a day for Chilling of
20000 liters of raw milk from 30 degree centigrade to 4 degree centigrade per day.
2.Insulation of floor

          Cleaning the surface to be insulated for an approximate area of 20m2
          Application of one or more coats of Bitumen T-30 Primer on the floor.
          Providing and laying of 2 mm thick Tar felt as 1st layer.
          Providing 100mm thick High Density EPS (Thermocole) slabs having density of
          18kg/m3 and coefficient of thermal conductivity not greater than 0.027 W / mK , of in
          2m x 1m size with bitumen.
          Providing and laying one layer plastic felt, as water barrier, above the HD insulation
          with bitumen and sealing all the joints perfectly with bitumen.
3.Insulation of Chilled Water Tank

       Cleaning the surface to be insulated with the help of brushes to remove rust etc.
       Application of one or more coats of Bitumen T-30 Primer on the sides of IBT

       Providing 100mm thick High Density EPS (Thermocole) slabs having density of
       16kg/m3 and coefficient of thermal conductivity not greater than 0.027 W / mK , of in
       2m x 1m size with bitumen
       A coat of bitumen of 85/40 or 85/25 confirming to IS702 at 1.0kg/m2 shall be applied
       over the flooring and alkathene sheet shall be press laid to act as a vapour barrier.
       Bitumen shall then be applied on the alkathene sheets and one side and edges of the
       insulation slabs to ensure total rate 2kg/m2 between contacting surfaces. The slabs are
       then be fixed in position ,making sure that there shall be no joints between slabs.
       For double layers insulation ,bitumen shall again be applied on all contacting surface to
       ensure a total rate of 1.5kg/m2 between contacting surfaces.
       A coat of bitumen at 1.5kg/m2shall be applied over the insulation surfaces.

   The quantities given are notional and may vary to plus or minus side while finalising the
drawings. Payment will be effected only for the quantity executed at site.

 5. Exclusions:

  Any civil works for the plant are excluded from the scope of the Contractor. This will be
 carried out by the client.

 6. Testing / Test Certificates

      The Party shall produce the Test Certificates for all the materials such as PUF, SS Sheet, CRS
 sheet, Fastening & Sealing Materials etc intended to be used for the mentioned work. Inspection
 during the works will be carried out by the engineers by the concerned dairies.
 7.Equipment to be supplied , , erected, tested and commissioned by the Contractor
1    Main Compressor (6” X 6”) with 60,000 kcals/Hr. with flywheel, 1 Set.
     accessories                       Motor Pulley and Gauge-cum-
                                       control panel comprising of LP,
                                       HP & OP cutouts with necessary
                                       internal wiring and MS Guard
                                       for pulley side.
2    Squirrel cage Induction Motor 33 kW/ 40 HP Reputed                1 Set
     with suitable foundation railing, indigenous make TEFC Squirrel
     and foundation bolts..            cage Induction motor energy
                                       efficient (93%) for the above
                                       compressors suitable for the
                                       operation on 400/440 volts, 3
                                       phase, 50 HZ, 1440 RPM, AC
                                       supply. thermal protection
                                       winding class F insulation.

3                Starter                  Suitable for the above motor 1 set
                                          solid state    L&T ML6 ( or
                                          equivalent)    with    standard
                                          accessories,    single    phase
                                          preventer ,motor protection
                                          circuit breaker , and Amp &
                                          Hour meter.

4    NRV & Oil Separator                   Suitable for the above                  1 Set
5    Refrigeration pipes, water pipes      Suitable for the above               1 Lot
6    Controls                              Electronic       float     valves,   1 Set.
                                           electronic controls LP & HP cut
                                           out unloading solenoid valve , by
                                           pass arrangements with Direct
                                           expansion valve and control
                                           wiring including materials
7    Valves & Fittings                     As required                          1 Set
      Oil purging systems with headers     Oil/air purging system from          1Set
8    and 15 NB valves                      evaporative coils, receiver etc
     MS pipes /GI pipes , fittings, valves,                                     1Set
     flanges, etc for ammonia lines and
10   water lines                            As required
11   Chilled water pump with high           5HP                                 2Nos.
            efficiency motor
                                                                                       1Lot
                                                                                       (Appr.
                                                                                       Length
            Chilled water lines GI class B 80                                          100
12          NB                                     As required                         meters.)
                                                                                       1Lot
                                                                                       (Appr.
                                                                                       Length
            Insulation material for chilled water                                      100
13          line                                  As required for80NB line             meters.)

8.Refrigeration , Chilled water , Condenser& Cooling Tower Pipes lines :
    a) Ammonia discharge and suction headers (Approx.length of 14 mtrs of 2”size) and
        suction and discharge tapings to the compressor with NRVand valves.
    b) Suitable liquid line, Air purge & oil purge lines and Pressure equalization lines with control
        valves .
    c) Suitable head cooling water lines for compressors with control valves.
    d) Suitable forward and return water lines of cooling tower(90TR,Paharpur Make) with control
        valves.
    e) Chilled water suction header and discharge header of size 100 NB with filter on the
        suction line and 100NB valves(audco butter fly type) on both side of filter,
        individual 80 NB valves (audco butter fly type) and vertical NRV at the discharge
        lines and 80 NB valves (audco butter fly type) at suction side for each pumps.
    f) 80 NB GI B class chilled water line from chilled water pump discharge header to milk
        chiller & return line to IBT. Audco make butterfly valves 80 NB at the inlet and out let
        of the Heat exchanger.
    g.) Any additional pipe lines / equipment required for the smooth functioning of the
       plant may be considered
  9.Approved Pipes, Valves & Fittings:
Refrigeration Pipes                :TATA MC C Class or eqv.
Water Pipe                         : TATA B Classor Eqv.
Water lines                        : TATA B Classor Eqv.
Refrigerant Valves                 :Frick / Super make
NRV                                :Inter valve.
    10.LIST OF EQUIPMENTS / ITEMS SUPPLIED BY THE CLIENT FOR ERECTION,TESTING
                      AND COMMISSIONING BY THE CONTRACTOR

1         Main Compressor (6” X 6”) with 60,000 kcals/Hr. with flywheel, 1 Set.
          accessories                      Motor Pulley and Gauge-cum-
                                           control panel comprising of LP,
                                           HP & OP cutouts with necessary
                                           internal wiring.
2         Squirrel cage Induction Motor 33 kW/ 40 HP Reputed                1 Set
          with suitable foundation railing indigenous make TEFC Squirrel
          and foundation bolts..           cage Induction motor energy
                                           efficient (93%) for the above
                                           compressors suitable for the
                                           operation on 400/440 volts, 3
                                           phase, 50 HZ, 1440 RPM, AC
                                           supply. thermal protection
                                           winding class F insulation.

3                   Starter               Suitable for the above motor       1 set
                                          solid state     L&T ML6 ( or
                                          equivalent)     with    standard
                                          accessories,     single    phase
                                          preventer ,motor protection
                                          circuit breaker , and Amp &
                                          Hour meter.
4                Ice bank tank            size 7.5mtr long X 2.25mtr width   1set
                                          X 2.35mtr. Depth with coils
5             Ammonia Receiver            3.3mtr long X 0.76mtr dia          1No
6           Shell and tube condenser      2.6mtr.X 0.60 mtr.dia              2Nos.
7            Condenser water pump         5HP,7.5HP                          2Nos.
8                Cooling Tower            90 TR Pahpur make                  1No
9               Agitator for IBT          7.5 HP                             1No
 SUPPLY & INSTALLATION OF COLD STORE INSULATION WORKS
 AT PALAKKAD DAIRY & KASARGOD DAIRY

 Functional Requirements:

  1.Kasargod Dairy: MRCMPU wants to set up a cold store with a floor area of 35 Sq. Mtr. in
 Kasaragod dairy intended for the storage of curd at 10 degree centigrade in 500 ml packets
 (kept in milk trays of 10ltr. Each).The capacity of the AHU prepared is 10TR.

 2.Palakkad Dairy: The existing cold stores at Palakkad is to be expanded by constructing an
 additional area of 80M2 for the storage of milk in sachets at a temperature of 4 degree
 centigrade. New cold store should be capable of making the refrigeration requirements for the
 storage of 32000 liters of milk in sachets at 4 degree centigrade. The liquid line & suction line
 can be tapped from the existing liquid & suction headers.

                          COLD INSULATION WORKS
    A. Scope:

Pre-fabricated material for Cold insulation for the Cold store & Ante room for
maintaining the area to 4OC for Cold store and 8OC Anteroom as per the technical
specifications as follows:

     a) Insulated panels for roof and sides.
  Scope of Supply includes the 80 mm thick POLYURETHANE FOAM (Puf) sandwich panel
(Thermal conductivity shall not exceed 0.027 W /m K) with interlocking cum lock facility and
fastened rigidly with each other with necessary fasteners will be of stainless steel. Pressure
insulated puf panels shall be given with unique high density of 40 - 42 kg / m3 flawless, fire
retardant materials. All interior and e exterior panels are mild ribbed to have rigidity and proper
addition with the puf materials. The panel shall be suitably jointed using camlocks and silicon
sealants
  b) Wall side panel: POLYURETHANE FOAM (PUF) Panels of 80-MM thick with
lamination of 0.5 mm thick stainless sheets on one side and Plain GI on the other side
abutting with the wall, with the width of 1200 mm. The panel will be suitably jointed
using camlocks and silicon sealants.
  c)Exterior panels & Top/ Roof panels : POLYURETHANE FOAM (PUF) Panels of 80-
  mm thick with lamination of 0.5 mm thick SUC 304 grade stainless steel for inside and Plain
  GI on the other side with the width of 1200 mm for CEILING of the cold storage. The
  panel will be suitably jointed using camlocks and silicon sealants.
To prevent possible damages to the inner panelling 1.6 mm thick SS sheet shall be provided as
skirting up to height of 400 mm from floor level.

The sealing and caulking materials used would be of good grade of ISI quality.

g) Heavy Duty Sliding doors with air curtains for Cold store

HD Sliding type insulated 80mm PUF single door type as per standards shall be provided at
the appropriate location with a size of 1200 x 2000 mm with Air curtain. Adequate SS supports
for the doors on all sliding / supporting edges shall be provided with latching arrangements. SS
cladding at all sides with 0.5 mm SS 304 material with SS beeding shall be provided. The doors
shall have suitable heavy duty latch with locking arrangements.

  h)Lighting: Adequate lighting- 11 W moisture proof CFL for standard working.
  Vision Panel – as per site conditions.

 B: Approx.quantity schedule for Supply
      1. Palakkad Dairy
      Approx.    Approx.  HD Cold
     Panel Area    Panel Store Doors
                   Area    with Air
       Walls     Roof      Curtains
      (Sq.m.)    (Sq.m.)    (1200
                         x2000)mm
        140         80        2
       2. Kasargod Dairy
      Approx.      Approx.  HD Cold
     Panel Area      Panel Store Doors
                     Area    with Air
        Walls      Roof      Curtains
       (Sq.m.)     (Sq.m.)    (1200
                           x2000)mm
         140          35        2
c)Floor Insulation

Specification & scope of works

       Cleaning the surface to be insulated
        Application of one or more coats of Bitumen T-30 Primer on the floor.
        Providing and laying of 2 mm thick Tar felt as 1st layer.
        Providing 100mm thick High Density EPS (Thermocole) slabs having density of
        18kg/m3 and coefficient of thermal conductivity not greater than 0.027 W / mK, of in
        2m x 1m size with bitumen.
        Providing and laying one layer plastic felt, as water barrier, above the HD insulation
        with bitumen and sealing all the joints perfectly with bitumen.


                          Sl.No. Dairy                    Cold Store
                          1      Kasargod                 35 sq.m
                          2      Palakkad                 80 sq.m

  The works mentioned above shall be done in spells of 3 or more depending up on the site
  conditions without affecting the smooth functioning of the dairies..


f ) The electricals: Power will be provided at the panel board of the supplier by the Dairy
concerned. The wiring to the equipments has to be carried out by the party for all the Air
curtains & all the illumination arrangements. Vision panel shall be provided as per sight conditions.

        The area given above are notional and may vary o plus or minus side while
    finalising the drawings. Payment will be effected only for the quantity executed at
    site.
        Any additional requirements / reduction in measurements of panels, HD Doors,
    Sliding Doors etc shall be supplied as per approved rates, if found necessary during
    finalisation of drawings.

  C. Exclusions:

  Civil works for the cold stores are excluded from the scope of the Contractor. This will be
  carried out by the client.

  D. Testing / Test Certificates

       The Party shall produce the Test Certificates for all the materials such as PUF, SS Sheet, CRS
  sheet, Fastening & Sealing Materials etc intended to be used for the mentioned work. Inspection
  during the works will be carried out by the engineers by the concerned dairies.
 TECHNICAL SPECIFICATION OF REFRIGERATION AIR HANDLING EQUIPMENTS
                 PALAKKAD DAIRY & KASARGOD DAIRY

Sl.
                                        Description
No.
       AHU 1SET EACH (For Palakkad Dairy and Kasaragod Dairy)
1.     Ceiling suspended / Wall mounted type Frigid Coil Air-Cooling Unit
       with coil section, blower section, drain pan, accumulator and
       defrosting arrangements etc. The coil section shall be fabricated from
       ¾” OD x 16 G MS ERW tubes, which shall be hot, dip galvanized
       after its fabrication. The blower section shall be comprising of 2 nos.
       high efficient axial flow fans to be directly driven by suitable capacity
       TEFC squirrel cage induction motors. Capacity of the cold store
       diffusers shall be minimum 10TR each
2.     Controls & Instruments comprising the following.
       a.       1 no.     Electronic Float Switch
       b.       1 no.     Liquid Line Solenoid Valve

3.   M.S. ‘C’ class refrigerant pipes and fittings for the liquid line &
     suction line from the above air cooling unit to the existing liquid &
     suction headers.
4.   Suction line insulation with 2” thick thermoform, bitumen and
     finished with aluminum cladding.
Kasaragode Dairy
Schedule of pipes, valves & Cold Insulation

                                                                         Unit Rate per
 Sl.   Description
                                                                             R.Mt
 No.
1      MS Pipes and fittings for Ammonia lines 15kgs per cm2 Class
       C heavy ERW quality as per IS 1239(Rate should be inclusive
       of same quality bends, tees, reducers, MS flanges (Ammonia
       line flange)and valves as per BS table F, gaskets, bolts, nuts,
       etc. whichever necessary
1.1    M.S. ‘C’ class pipe of 2” for Desuper heater and suction line
       with valve1 number.( Appr.Length 24 M )
1.2    M.S. ‘C’ class pipe of 1 1/2” for the suction.( Appr.Length
       51M)
1.3    M.S. ‘C’ class pipe of 1 1/4” for the suction.( Appr.Length
       10M)
1.4   M.S. ‘C’ class pipe of ½” for the liquid line.( Appr.Length 51M
      )
1.5   Cold insulation with thermocole pipe sections HD-50mm thick
      fixed and sealed using 80/100 bitumin including cladding with
      24SWG Aluminium sheet and self threading GI screws for the
      following pipe lines
      Suction line of 2” size.( Appr.Length 61M )
      Suction line of 2” size.( Appr.Length 10M )

1.6   GI B Class pipes (rate shall be inclusive of same quality bends,
      tees, reducers, and MS flanges as per BS 10 TABLE D gaskets,
      bolts, nuts, etc. wherever necessary) conforming IS.1239.
      Head cooling water line ¾” size.( Appr.Length 45M )


Palakkad Dairy
Schedule of pipes, valves & Cold Insulation

                                                                         Unit Rate per
Sl.   Description
                                                                             R.Mt
No.
      MS Pipes and fittings for Ammonia lines 15kgs per cm2 Class
      C heavy ERW quality as per IS 1239(Rate should be inclusive
      of same quality bends, tees, reducers, MS flanges (Ammonia
      line flange)and valves as per BS table F, gaskets, bolts, nuts,
      etc. whichever necessary
1.1   M.S. ‘C’ class pipe of 1/2” for Desuper heater and suction line
      with valve1 number.( Appr.Length 90 M )
1.2   M.S.‘C’class pipe of ½” for the liquid line.( Appr.Length 90M )
1.3   Cold insulation with thermocole pipe sections HD-50mm thick
      fixed and sealed using 80/100 bitumen including cladding with
      24SWG Aluminium sheet and self threading GI screws for the
      following pipe lines
      Suction line of 2” size.( Appr.Length 90 M )




SUPPLY OF MECHANICAL POUCH FILLING MACHINE
FOR MILK &CURD
TECHNICAL SPECIFICATIONS
A. MILK POUCH FILLING MACHINE CAPACITY: 5000 Packs/Hr.
MECHANICAL TYPE.

1.0      FUNCTIONAL REQUIREMENTS

          Milk would be fed by gravity flow to the float operated balance tank of the pouch
          filling machine. The machine should form pouches of film, fill with milk and seal
          the same.
2.0.    DESIGN REQUIREMENTS

2.2.    Capacity : 5000 packs/Hr of sizes 200 ml, or 500 ml or 1000 ml.
2.3.    Accuracy of Filling               + / - 2ml
        2.2.1 To get consistent Accuracy on Filling, Electro - Pneumatic filling technology
              shall be opted.
        2.2.2 Additional power consumption ( for compressed air) in the case of Electro -
              Pneumatic system shall be mentioned clearly.
2.4.    Accuracy on Bag length            + / - 2 mm
2.5.    Leak Percentage                   Maximum 0.3%
2.6.    Speed ( For 500 ml Packets) 40 packets / minute ( with option to change
                                          42 packets / minute
2.7.     Finish : All stainless steel surfaces are to be polished to 150 grits.

3.1 SCOPE OF SUPPLY
3.2 All the fabrication material used shall be approved quality, corrosion resistant and
    sturdy for human operations. The top SS plate shall be adequately strong enough to
    carryout maintenance of the controls mounted upon it.
3.3 Milk contact parts:
       Milk contact parts of the machine should be made from stainless steel conforming to
       AISI 304.
3.4     Float Balance tank – 40 mm puf insulated – sanitary design: _ 1 set
       S S 304 make of capacity at least 50 litres, common for both filling heads. FBT shall be
       insulated with 40 mm thick, 38–40 kg/ cu.m, puf. It shall be sanitary design and shall
       be fabricated out of 2.5 mm thick SS 304. The top cover shall not be insulated. It shall
       be provided up on the top SS sheet of adequately thick and supported the machine,
       clamped in a way so that no sweating of water to the machine parts mounted below

3.5     The machine should have following arrangements in it.
3.5.1   Film guard device to stop the machine when the film gets exhausted.
3.5.2   Liquid level controller.
3.5.3   UV Sterilising mechanisms for pouch film.
3.5.4 Milk Pouch counter.
3.5.5 Apportioning device for 200 ml.; 500 ml, and 1000 ml.
3.5.6 Facility to insert a closed circuit in place cleaning system for the machine.
3.5.7 The machine should be also provided for
      -      solid state relay.
      -      stabilised power supply, system for the control.
                        -      turn down to 50 % capacity.
3.4.8 Date Coding devise :- Reputed make is included

3.6 Tools: Essential special tools should be supplied for the machine without charging
             any extra cost.
Available Services:
      Elec .Power                      - 3 Ph + N
      Compressed Air                   : 4 kg/ sq.cm

The total Electrical load, Cooling water consumption, Compressed Air etc; all both in quantity
& quality shall be clearly informed.
3.0. The existing platform foundation, milk inlet and other services should be used for the
      new machines also. Hence you have to take care of the milk inlet, CIP, water
      connections, power etc to suit the existing facilities at Dairies.
PURCHASE OF SS PIPES & FITTING


Sl                                             Approx. Quantity
No         Item Description                        Required.
                                      Unit   Kannur Kozhikokde
                                              Dairy       Dairy
1    63.5 mm Butterfly valve          Nos                   10
2    63.5 mm SMS 2 way plug valve     Nos                    1
3    63.5 mm SMS 3 way plug valve     Nos                    4
5    63.5 mm SMS union                Nos                   22
6    63.5 mm SS Bend with unions at   Nos                   10
     both end
7    63.5 mm SS pipe                  Mtr                23
8    63.5 mm Plain Bend               Nos                10
9    63.5 mm Pipe clamps              Nos                24
10   51 mm Butterfly valve            Nos                14
11   51 mm SMS 3 way plug valve       Nos                6
12   51mm SMS union                   Nos                30
13   51mm Plain Bend                  Nos                10
14   51mm SS Bend with unions at      Nos                10
     both end
15   51mm SS pipe                     Mtr                46
16   51mm Support pipe                Mtr                12
17   51 mm Pipe clamps                Nos                36
18   2” SS, 304 SMS Union             Nos      72
19   2” SS, 304 Expandable bend       Nos      24
20   2” SS, 304 Short bend            Nos      12
21   2” SS, 304Tee                    Nos      24
22   2” SS, 304Dummy nut              Nos      20
23   2” SS, 304 Valve 3 way           Nos      10
24   2” SS, 304 Valve 2 way           Nos       6
25   2” SS, 304 Flanged valve 2 way   Nos       3
26   2” SS, 304 21/2” X 2” reducer    Nos       6
27   2” SS, 304 pipe                  Mtr      60
        SPECIFICATIONS OF PIPES&FITTINGS

Specification for stainless steel pipes:

  1. Type: TIG welded, annealed and de-scaled pipe manufactured as per standard
           ASTM-A270.
  2. Finish: Outer surface should be mirror polished and inner surface should be
           pickled as per Dairy standard.
  3. Length: The pipe length should be 6 meters +/-5 mm. each length of each pipes
           should be written on it with paint.
  4. Thickness: Thickness of pipe should be 1.6mm for all the diameters unless
     otherwise specified.
        Specifications of valves and fittings:

   1.                 Valves: Valves should be provided with complete union in all ends. The valves
                  should be easy to dissemble and assemble and leak proof.
   2.                 Unions: These should be complete with liner, male and femail parts.Liner and
                  male parts should be suitable for expansion joints.
   3.                 Thickness: Thickness of fittings made from tube section should be 1.6 mm for
                  all the diameters unless otherwise specified.
   4.                  Finish: Outer should be mirror polished and inner surface should be pickled as
                  per Dairy standard.
   5.                 Bends: The bends shall be true 90 degree and with or without unios as specified
                  in the scope of supply
   6.                  General: Threads of male or female parts of all unions should be easy to tighten
                  or loosen and should be leak proof when tightened normally. The valves and unions
                  should be complete with suitable gaskets of Dairy standards.


        STEAM BOILER 1 TON
        SPECIFICATION OF EQUIPMENT

        AGRO WASTE FIRED BOILER OF 1000 KG/HR CAPACITY ALONG WITH
        ACCESSORIES
                             FUNCTIONAL REQUIREMENTS

1. General Description: The Agro Waste fired boiler would be required to generate dry
   saturated steam 1000 kgs/hr from and at 100 deg centigrade at 10.5 kgs/cm2,for use in
   various processes in the dairy plant.
2. Capacity and Design Pressure:       Capacity, working pressure and quantity of steam for
   the boiler should be as per the details given in Para 8.0&9.0

3. Accessories Required:
     a. Two Centrifugal multistage feed water pump with motor and base frame
     b. One Induced draft fan with motor and base frame
     c. Set of Doors for fuel charging, access and ash removal
4. DESIGN REQUIREMENTS:
     a. Dryness of steam: Dryness of steam required is 90%. .
     b. The boiler should be a fire tube, three pass boiler having a refractory lined internal
        furnace with baffle wall design
     c. Fuel: The boiler should be designed to use agro waste fuel of gross calorific value as
        given below: Husk: 3300 Kcal/kg, Crushed Coconut shell:4500 kcal/kg, Wood:
            3000 Kcal/Kg
     d. Thermal Efficiency: Thermal efficiency of fuel on NCV basis under normal
        working conditions should not be below 60%.

5. STATUTORY REQUIREMENTS:                    The boiler should comply with the latest Indian
   Boiler Regulations (IBR). The manufacturer should possess International Standards
   Organization (ISO 9000)certification, ASME Stamp and other statutory requirements and
   as per the specification here under.
   The manufacturer should have at least 10 working installation of same design in Kerala
   with the names and capacity mentioned clearly.
  The electrical equipment, installation should comply with the latest Indian Electricity
  Regulations and local CEIG regulations. The supplies should conform to the approval of
  statutory authorities and any modifications (if any) suggested by the authorities shall be
  carried out by the supplier without any additional cost. IBR certificate shall have to be
  handed over to the buyer.
  The entire boiler should be stress relieved.
  QA plan to be enclosed.

6. SCOPE OF SUPPLY:
     a. The complete boiler having steam-generating arrangement, Refractory lined internal
        furnace, ID, pumps, controls, instrumentation and all necessary accessories should
        be supplied. Refractory items conform to IS 8 & IS 6 standards
b. One Pressure parts consisting of shell and smoke tubes assembly with necessary
   openings for valves and fittings, manhole, mud hole etc.
c. Set of CI grate bars with supports
d. Suitable thermal insulation on the outer shell covered by galvanized MS sheets of
   minimum 20 Gauge thick and duly painted with two coats of aluminium paint. The
   temperature of the outer shell should not be 10 degrees more than ambient temp.
e. Feed Water Pumps: Two feed water multi stage horizontal centrifugal pumps, to
   match the capacity of the boiler (one for duty and one standby) should be supplied
   with suitable motors. Pump to be provided with mechanical seal. The pump should
   be capable of running at high temp and pressure (Maximum discharge pressure
   suitable to match the maximum steam pressure generated by the boiler. The temp.
   could be up to 90 deg. Celsius to pump the condensate to boiler) Class of insulation
   and number of stages should be accordingly selected. The pumps should be supplied
   with suction strainer, suction isolating valves, non-return valves, 100mm dia
   pressure gauge on delivery side and feed check valves. Feed water piping from feed
   water service tank in boiler house to feed water pump and then to boiler should be
   supplied and installed by the supplier. A 100-dia pressure gauge should be supplied
   and installed by the supplier. A 100 – dia temperature – indicated gauge should be
   provided to measure the temp of feed water.
f. ID fan System: ID fan capable of overcoming the resistance of the system and
   accessories.
g. Ducting: One set of flue gas ducting made from suitable MS sheet should be
   provided for connecting flue gas outlet of the boiler to the chimney. The duct
   connection to the chimney and making good of the chimney opening is included in
   the scope of work.
h. Control Panel: The complete control panel-housing, push buttons, indicating lights
   and window enunciator temp. Controller and indicators, pressure gauges etc. should
   be supplied. The control panel should be made from 14 gauge mild steel sheet duly
   painted. It should also have audit alarming system for all the fault condition, which
   should appear visually on enunciator window. The circuit to include a FILL/FIRE
   system and interlocks for the combustion system
       i. Few of the fault conditions are:
             1. High Flue gas Temperature Control
             2. If the flue gas temperature goes above the set value, boiler should be
                 stopped and there should be audiovisual signals.
             3. Low water level should energise the audiovisual alarm.
                  4. The hooter should stop once it is acknowledged but the annunciator
                     should glow till the time fault conditions are cleared.
      i. Following controls also should be provided.
            i. To maintain steady steam pressure, switch to control the fuel combustion
               should be provided.

7. Boiler fitting and accessories:     Boiler should include all necessary standard mounting
   and fitting as listed below for safe and efficient operation in accordance with the latest
   IBR. Any component not listed in this specification but is required as per the statutory
   regulation shall be supplied by the supplier without any additional cost.

8. PIPING WORK: One set IBR piping between feed water pump and boiler inlet
      a. VALVES IBR APPROVED Three                 Isolating valves on feed water line from
         pump to boiler
      b. Two Non return valve at pump outlet
      c. One Non return valve on boiler feed water inlet line
      d. One Main steam stop valve
      e. Two Single port spring loaded safety valves. Spring loaded safety valve having a
         combined total discharge rate exceeding the maximum steam producing capacity of
         boiler with exhaust pipe to discharge outside the boiler house
      f. One Air vent valve on boiler
      g. Two Isolating valves for pressure gauges
      h. One Blow down valve
      i. One Water level control drain valve
      j. Two Water level controller isolating valves
      k. Four Gauge glass isolating valves
      l. Two Gauge glass drain valves
      m. One Auxiliary steam valve

9. INSTRUMENTS, CONTROLS AND SAFETIES:
     a. Two Gauge glasses with shield
     b. One Magnetic water level controller
     c. One Main steam pressure gauge
     d. One Temperature indicator cum controller for high flue gas temperature interlock

10.ELECTRICALS:
     a. One M.S. free standing, dust proof pre-wired control panel incorporating power
        circuit and control circuit.
     b. The control panel should have suitable incoming and outgoing feeders all located in
        independent compartments. All contractors, switches, starters, HRC fuses, relays,
           terminals etc. should be neatly mounted and pre-wired in the panel board
           terminating in a TPN switch fuse unit. All fuses should be HRC link type. The
           components of the control panel should also selected as follows:


                i. Aluminium bus bars with current density of 0.8 A/sq. mm shall be provided.
                   The bus bars should be insulated with heat shrinkable sleeves and supported
                   one epoxy – based insulators.
               ii. Earth bus of aluminium section suitable for 150A shall be provided at the
                   bottom of the panel and the same shall be mounted outside the panel
             iii. Minimum rating of contractor shall be 16 Amps.
              iv. Minimum SFU rating shall be 63 Amps.
               v. All contactors shall have rated coil voltage of 230 V.A.C Individual isolators
                   and fuses shall be provided for each of the outgoing feeders. Each feeder
                   shall have over load relay and single phase preventer.
              vi. The wiring within the panel shall be done using copper cables. Minimum
                   section of power cables shall be 2.5 sq.mm and that of control cable shall be
                   1.5 sq.mm. Indicating ferrules at both cable ends shall be provided. Lugs
                   shall be provided at flexible cable ends.
      c.   Star Delta starters shall be provided for the motors of 10 HP and above. DOL
           starters shall be provided for the motors of less than 10 HP. However, for feed water
           pumps DOL starters may be provided irrespective of pump horsepower.
      d.   All controls, starters, fuses, isolator, heater ON/OFF push button indicating lamp
                etc. Shall be mounted in the panel and the same shall be dust and vermin proof.
      e.   Indicators, rotary switches etc. shall be provided on top of the panel and the same
                shall be at a convenient operating height.
      f.   The panel shall be completely pre-wired. The electric supply shall be 415 volts, 50
           Hz. AC
      g.   The panel board shall be installed in boiler house as per approved layout.
      h.   Necessary isolators near motors shall be provided as per statutory requirement.
      i.   All feeders above 10HP to be provided with ammeter without selector switch.

11.Painting: All the exposed MS surfaces shall be thoroughly cleaned with sand blasting
      followed by two coats of heat resistant anti corrosive primer followed by two coats of
   heat resistant paint.

12.AIR DUCTING          One set Primary and secondary air ducting along with damper
   assembly
13.FLUE GAS
      a. One Flue gas damper at ID fan inlet
     b. One Expansion bellow at inlet of ID fan Main doors
14.Boiler Mountings and Fittings:
     a. Main steam stop valve with counter flanges – 1 No.
     b. Non return valve for main steam cast steel with SS working parts with counter
           flanges – 1 set



      c. Blow down valve with counter flanges and necessary handles for operating the
         valves with blow down key and necessary pipes and fittings up to blow down pit.
      d. Steam stop valve with counter flanges for auxiliary steam connection. 1 No.
      e. 200 mm dia steam pressure gauge with siphon tube and cock. 1 No.
      f. Auxiliary steam connection with cock for fixing test pressure gauge and for removal
         of air. 1 set
      g. Water level sight glasses with safety shields and isolating cocks. 2 sets
      h. High and low water level alarms with isolating valve and drain point having a
             drainpipe up to blow down pit. 1 set
      i. Access ladder service platform and top walkway platform complete with railings. 1
         set
      j. Flue gas temperature indicator (digital type) 1 no.
      k. Steam pressure switch for combustion controls by interlocking with fan.
      l. Feed line suction strainer 2 nos.
      m. Isolating valve for strainer 1 no.
      n. F/w sampling line with isolation valve 1 each
      o. Feed water line pressure gauge with valve 1 set
      p. Siphon tube with threaded flange
      q. Fusible plug
      r. Water flow meter at the suction of feed water pumps for measurement of water
         consumption in the boiler. The meter should be suitable to withstand water at higher
         temperatures – 1 no.

15.Chimney: Self-Supported Chimney with foundation bolts, nuts, segmental platform at flue
   gas sampling point stub, cage Ladder chimney hood and painted with Red-oxide primer
   and over which two coats of Aluminium painting on outside of the chimney. Approximate
   dimensions are: Top dia 500 mm, Bottom ID 1300 mm, minimum Height 30.5 mtrs
   (conforming to pollution control norms). Material IS 2062, Thickness 10,8,6 mm, Bottom
   plate 36 and 20mm thk with 1550 PCD. Chimney to be provided with aviation lamps and
   lightening arrestor and strip connected till the bottom.
16.Pressure reducing station: Suitable pressure reducing station with bypassing arrangement is
   also included in the scope of supply. Inlet pressure 10.5 kg /cm2 , outlet pressure 3.5 kg
   /cm2, steam flow 1000 kg /hour.
17.The scope of supply also include LP steam line for about 30 m from the boiler house. Rate
   for the same shall be quoted per meter basis each shall include cost of materials for
   supports, heat insulation and cladding with 25 m aluminum sheets, steam traps shall be
   provided at suitable locations (2 nos).
18. Erection and commissioning
      a. Scope of work: The scope of work includes positioning of the boiler on foundation,
          connecting      feed water, oil and drain lines, steam line (high pressure, low
          pressure and pressure reducing station) up to utility point, safety valve vent line
          outside building and blow down lines, up to blow down pit, connection to electric
          motors, earthing, fabrication of ducting as per layout etc. complete.


      b. The following items shall be supplied and installed by boiler manufacturer as per
         scope of supply pt. 6.0 and battery limits mentioned at 19.0
              i. Necessary steam, water and fittings along with all pipe accessories, valves,
                 NRV's, flanges etc. The return pipes from the boiler/filter to the service tanks
                 are also included in the scope of work.
             ii. Insulation of steam line up to utility point and cladding with 24-gauge
                 aluminium sheet.
           iii. Asbestos rope insulation of drain lines and safety lines as per requirement
            iv. All foundation bolts
             v. Supply and installation of cables, wires, earthing materials etc.
            vi. Necessary bolts, nuts, fittings, consumables, tools and tackles and labor for
                 the job.
           vii. Supply and installation of steam vent pipes along with valves, safety valves,
                 flanges and all other accessories.
          viii. Supply and Installation of Controls & Instrumentation
      c. The supplier should transport the boiler after receiving intimation regarding
         readiness of the foundation. Boiler should be insured, transported and unloaded on
         the foundation by the supplier.
      d. All mountings, fittings, accessories etc. should be installed, aligned and piping,
         electrical connections etc. should be carried out as per the latest Engineering
         Practices by qualified agency having class 'A' Electrical license in Kerala.
      e. Ducting should be fabricated after getting the drawings approved from the Engineer-
         in- charge and the Statutory Authorities.
      f. For commissioning and trial run of the boiler necessary materials for 1st charge like
         lubricating oil, grease, cleaning chemicals etc. shall have to be supplied by the
         supplier. However the concerned plant shall supply water, fuel etc.
      g. After commissioning of the boiler, it shall be under performance observation for a
         period of 1 week under our operation before handling over to Plant. During this
         period, proper logbooks should be maintained and the Engineer-in-charge shall attest
         the same.
      h. The erection and commissioning should be carried out as per general terms and
         conditions of erection contract mentioned in the tender and as per the instruction of
         Engineer-in- charge. Detailed work schedule should be prepared and got approved
         from Engineer-in- charge.
      i. The dairy plant is under full fledge operation and the works are to be carried out in
         such a way that the day-to-day plant operations are not disturbed during the
         execution of the works. If the plant shut downs are required for the service
         connections, prior intimation is to be given. As and when plant shut downs are
         made (based on the convenience of the plant and as agreed by the Engineer in
            charge), work has to be carried out giving utmost priority so that shut down
         periods are kept bare minimum. Work should be carried out maintaining high
         standards of workman ship and maintaining high standards of discipline and
         hygienic conditions.

19.Battery limits:
      a. Feed water: The scope of work is from inlet of the raw water pump before softener
         and filter and from the suction of the recirculation pumps
      b. Flue gas: The scope of work includes complete work.
      c. Steam: Up to existing main steam line
      d. Blow down:The scope of work of bidder is up to blow down pit located just outside
         the boiler house.
      e. Drains: All drains from water level controllers, gauges shall be taken outside the
         boiler house. Slurry to be taken out of the boiler house.
      f. Fuel gas: Ducting from boiler to WPH, from WPH to Scrubber, scrubber to ID and
         from ID to chimney to be provided, Chimney will be a common chimney capable of
         operating two boilers at the same time
      g. Electrical: The purchaser/client shall provide incoming electrical connection to the
         bidder's boiler control panel. From control panel the bidder shall do all control cable
         work. All the cable trenches and earthing shall be done by the purchaser
      h. All civil works including the building and foundation for boiler and accessories shall
         be provided by client/purchaser. However, all necessary bolts, nuts, templates etc.
             shall be provided by the bidder. All trenches shall be provided by the
             client/purchaser but necessary steel supports/cable trays etc. for piping/ducting
         and cabling etc. are in bidder's scope. Necessary drawings shall be provided by the
         supplier on receipt of order
      i. Feed water service tank of capacity 1500 litres is included in the scope of Supply,
         Erection, Testing and commissioning.

20.Exclusions:     Boiler house civil work and foundations, Incoming electrical connection to
   boiler control panel, power cabling, earthing and Effluent treatment plant.

21.This is a complete turn key job for supply, installation, testing and commissioning of steam
   raising plant and any items not mentioned above but required for completion of supply,
   installation, testing and commissioning of the plant shall be supplied and installed by the
   boiler supplier without claiming extra payment.

22.Details of the Boiler:
     a. Capacity: Continuous water evaporation rate of 1000 kg/hr – Quantity 1 No
     b. Length of flue gas ducting - Flue gas duct must be provided from the boiler to
         chimney.
     c. The supplier shall quote their for MS ducting per M basis
     d. The supplier may have to carry out ducting for the existing boilers of 600Kgs/hr
         capacity up to the new chimney
23.Water flow meter - Meter should be suitable to withstand water at higher temp.

24.Technical details of the boiler shall be as furnished below:
      e. Boiler General details
             i. Type of boiler: HORIZONTAL MULTI TUBULAR SMOKE TUBE SHELL
                TYPE BOILER
            ii. No. of passes: TWO PASS
          iii. Steam Generation: 1000 kg/hr. from and at 100 degrees centigrade water.
           iv. Steam conditions:        Max. Total solids (ppm) Nil
                          Silica (ppm)                     Nil
                   Dryness of fraction               0.90
            v. Steam pressure: Safety valve set pressure (kg/sqcm):
                          1st stage            10.50 kg/sqcm.
                    nd
                   2 stage              10.25 kg/sqcm.
           vi. Firing cut off pressure switch setting:          10.00 (kg/sqcm)
          vii. Boiler Thermal Efficiency –
                   1. Boiler Efficiency (%) based on NCV of fuel at 100% load
                   2. Boiler Efficiency (%) based on NCV of fuel at 75% load
                   3. Boiler Efficiency (%) based on NCV of fuel at 50% load
                  4. Boiler Efficiency (%) based on NCV of fuel at 25% load

25.SPECIFICATIONS OF FEEDWATER TO BOILER
     f. Residual hardness as Ca CO3 ppm - 5 maximum
     g. PH value ppm - 8.5 to 9.5
     h. Oil content ppm - Nil
     i. Oxygen (O2)ppm - Nil
     j. Free CO2 ppm - Nil
     k. Bound CO2 ppm - 5 maximum
     l. Total dissolved solids ppm - 400 maximum

26.SPECIFICATIONS OF WATER IN BOILER
     a. Total hardness as CaCO3 ppm - 5 maximum
     b. Alkalinity ppm -15-20 % of TDS
     c. PH value ppm - 10.5 to 11
     d. Sodium Sulfite (Na25O3) ppm - 50 maximum dissolved
     e. P205 ppm – Nil
     f. Oxygen (O2) – ppm –Nil
     g. Total dissolved solids - ppm - < 3500

27.Connected Electrical Load
        No.                         KW                  Total
     a. Feed water pump
                                                     SUITABLE DRIVE TO BE
     b. Fuel oil pump
                                                     PROVIDED AND THE
     c. Electrical Heater                            BIDDER SHOULD INDICATE
     d. FD fan
     e. Recirculation pump
     f. Any other equipment

28.Utilities consumption at maximum rated capacity
      a. Fuel:           Wood / Husk
                                            This information must be furnished along
                                            with the bid for technical evaluation
     b. Electricity     (KWH)
     c. Water           (Kg/hr)
     d. Makeup for scrubber
     e. Pressure drop in scrubber
     f. Recirculation pump flow and head
29.Boiler dimension
     a. Over all dimension of boiler (Length x Breadth x height)
     b. Note - The boiler plant room drawing is to be enclosed by the bidder along with the
        bidding document
     c. Mechanical Details of the Boiler also must be submitted by the bidder for technical
        evolution

30.Heating surface area (sqm)
     a. Grate area
     b. Volumetric heat release rate
     c. Furnace volume
     d. Spirals Yes /No
     e. Spiral Type if provided
     f. Type of grate bar provided
     g. Tubes (All smoke tubes to be stay tubes)
     h. OD x thickness (mm) 63.5 x 3.66mm
     i. Quantity Nos. 2nd pass ->
            3rd pass - >                                                        .................
     j. Material construction ERW Tubes as per BS 3059 part 1

31.Shell
     a. Thickness (mm)
     b. Size (mtrs)
     c. Length (mtrs)

32.Material construction 2nd pass
                   3rd pass
33.Design code IBR 1950 with latest amendment
34.Water content when full (cum)
35.Steam space (cum)
36.Water content when at work level (cum)




37.Feed water arrangement
      a. No. of pumps
      b. Stand by water pumps
      c. Type of pump
      d. Capacity of each pump
      e.   Water flow meter provided         Yes/No.
      f.   Valves in water feed piping       Yes/No.
      g.   Stop valve at pump outlet              Yes/No.
      h.   Non-return valve at pump outlet        Yes/No.
      i.   Pressure gauge at pump outlet          Yes/No.

38.Firing arrangement:
      a. Fans trip on extreme low water level:    Yes/No.
      b. Fans trip on high steam pressure         Yes/No.
      c. Fans trip on flue gas tempt high         Yes/No.

   ID fan
      d. Type
      e. Rubber lined casing
      f. SS impeller
      g. quantity

39.Flue Gas Disposal
      a. Flue gas opening size on boiler (mm)
      b. Chimney
      c. Flue Gas ducting
      d. Flue gas temp/stack temp. (Deg. C)
      e. Settling chamber in Furnace:       Yes /No
      f. No of Layers of Refractory bricks in furnace

40.Automatic Water level controls.
     a. Quantity:
     b. Alarm and signal provided for
            i. Low level: Yes/No.
           ii. High level: Yes/No.

41.Boiler Mountings and Fittings
     a. Steam stop valve
     b. Non-return valve
     c. Safety valve
     d. Feed check valve (disc type)
     e. Blow down valve
     f. Air vent valve
     g. Water level gauge
     h. Steam pressure gauge
42.Structural:
      a. Inspection platform for boiler: Yes/No
      b. Provision of Access ladder for boiler Yes/No

43.Enclose QC manual giving details of various stage inspections Yes/ No

44.Boiler stress relieving Done: Yes /No

45.Pad Type hand holes provided: Yes /No

46.No of Fire doors:

47.No of Access/Observation doors:

48.No of Ash Doors:

49.Scrubber:

      a.   Flue gas composition
      b.   .inlet dust load
      c.   outlet emission at stack
      d.   pressure drop in scrubber

50.Boiler Losses: (Break up details of losses in % to be furnished on NCV basis)
                               Agro waste
     a. Dry stack loss                 %
     b. Sensible heat loss             %
     c. Moisture in air loss           %
     d. Radiation loss                 %
     e. Unaccounted loss                     %
     f. Total loss                           %

51.WATER SOFTENING PLANT

      a. Diameter                                     250 mm
      b. Height on Straight                                1200 mm
      c. Output between two regeneration for influent raw water hardness of 100 ppm as
         CaCO3 (Once in a day regeneration)                      40 m3
      d.   Resin Quantity                            67 Lit
      e.   Resin make                Thermax/Ion-Exchange/Equivalent make
      f.   Max. Working Pressure                            3.5 Kg/cm2
      g.   Max. Treatment Flow                       2.5 cum/hr
      h.   Min. Treatment Flow                       0.25 cum/hr
      i.   Common Salt required per Reg. Brine Tank         10 Kgs
      j.   Brine Tank (HDPE Tank)                           Suitable


52.TECHNICAL SPECIFICATIONS
     a. Water Softener Model should comprise following –
            i. Mild steel pressure vessel with inlet and outlet connections, resins, charging
               and withdrawal connections and supports a vessel painted internally and
               externally, internal painting with anticorrosive paint
           ii. Set of internals for the above comprising of raw water inlet Brine distributor
               and bottom collecting system
         iii. Brine Tank in HDPE construction to store and measure salt for Regeneration
               of the softener complete with brine level indicating clamp
          iv. Set of mild steel flanged pipe work including regeneration pipe work
           v. Multi-port valve for normal operation and regeneration
          vi. Hydraulically operated brine injector
         vii. Initial charge of ion exchange resin for the softener vessel
        viii. Test Kit
          ix. Set of inlet and outlet pressure gauges
           x. Set of inlet and outlet sample valves
          xi. Raw water will be provided free from turbidity, organic matter, oil and colour,
               chlorine and will be at ambient temperature


53.DUAL MEDIA FILTER
     a. Diameter                     400 mm
     b. Height on Straight                 1250 mm
     c. Maximum flow                 2.5 Cu-M/hr
     d. Minimum flow                 0.5 Cu-M/hr
     e. Op. Pressure                 3.5 Kg/cm2
     f. Back wash flow                     2.5 Cu-M/hr
     g. Mounting                           Side
     h. Valve Size                         40mm

54.TECHNICAL SPECIFICATIONS
      a. ONE - Dual Media Filter CZ FDM comprising of
            i. ONE - Vertical, welded mild steel pressure vessel complete with dished ends
               and internally coated with epoxy paint
      b. The vessel complete with manhole and cover painted externally with bituminous
         paint
      c. ONE - Set of mutually operated multiport valves
      d. ONE - Set of internals for the above comprising of raw water distributor and filter
         water collecting system
      e. ONE - Set of frontal pipe work of MS construction complete with vent piping
      f. ONE - Initial charge of filter media comprising of graded washed pebbles and
         anthracite
      g. ONE - Set of inlet and outlet pressure gauges
      h. ONE - Set of inlet and outlet sample valves

55.NaOCl Dosing System
     a. Material of Construction of Tank – HDPE
     b. Volume of Tank - 100 Ltr.
     c. Type of Dosing Pump - Electronic (Diaphragm)
     d. Dosing Rate Ltr./hr (maximum) – 6
     e. Head Kg/cm2- 3.5

56.Following items to be also supplied along with the treatment plant
      a. Hardness test kit
      b. Water transfer pump Assembly
      c. External piping and valves from the pump inlet
      d. Any other items which are not specifically mentioned in scope
INK JET CODING DEVICE
FUNCTIONAL REQUIREMENTS:

The Ink Jet Coding Devices are intended for providing coding of Mfg date, batch no.,
MRP etc on milk pouches of LDPE film and on labels and cartons of milk products
like Ghee bottles, tins, peda, Ice cream etc. The above devices are intended to use
in the Products Dairy and Kozhikode Dairy of our Union.
The Machine shall be suitable for printing on the following surfaces
  1. Laminated carton
  2. Pet / Glass bottles
  3. Cas coated Labels
  4. Paper labels
  5. Metallic tin surfaces
  6. Plastic bottles
  7. Polythene bags
The machine should be provided with adequate accessories so as to facilitate for
continuous printing of duplex cartons, labels, bottles, tins etc.


TECHNICAL SPECIFICATIONS
Character height – 2.5 mm to 8 mm
Type of Characters – Alpha numeric
No of lines (Adjustable) - 3 Lines
No of characters in each line – 10 Nos

There should be an option to increase / decrease number of lines or characters to subject a
maximum of mentioned above. The software should have the capacity to store 200 messages
printer. The system should also have capacity to print logos, standard bar coded, variable data
& informations

Operating environment – 15 to 45 Deg C
Ink colour – Black or Blue
Data interface – RS 232C at baud rates selectable up to 19.2 KBPS
Print head – Auto flush system should be there to eliminate daily print head cleaning, Nozzle
and gutter should be automatically cleaned before stopping.
Duration of continuous operation – 16 Hrs
Cooling – Air cooling
Supply Voltage – 120-240VAC, 50 Hz
Printing quality – high resolution high quality print
Resolution - 7.5 vertical dots per mm
Printing speed – 250 mts print
Screen - Color graphic screen LCD back light to be provided
Input signal, print target detection, printing stop, Reciprocative printing, and Rotary encorder
pulse.
Out put signal – Print ready, fault, warning, print in progress,
Fonts – 10 types
Password protection
Screen language – English
Cabinet – SS 304
Safety standard- Solvent evaporation should be reduced by Ink return system control, Food
grade Ink, There should not be any contact with surface and print head.
Viscosity and ink level control, Remote monitoring of printing errors
Impression cost per character in relation with various sizes should be indicated in the offer

Offer should contain
List of clients
List of consumables with cost
      List of service centers and distance from Calicut to the nearest service center
DEEP FREEZERS
FUNCTIONAL REQUIREMENTS:

Deep Freezers for storage / transportation of frozen products

TECHNICAL SPECIFICATIONS

Features shall be:
  • Sturdy design, outer body in powder coated steel sheet.
  • Inner lining with Aluminium sheet / SS sheet or any food grade metal.
  • Sheet metal components shall be chemically treated before powder coating for
     enhanced life and better finish.
  • Ergonomic design with sunken handles, spring-loaded door hinges and provision for
     locking / built-in locks.
  • High Density, high-pressure PUF Insulation for long holding times during power cuts
     and adverse environment conditions.
  • CFC free and using environmentally safe design.
  • Adjustable temperature controller for desired temperature settings that enables on to
     preserve a vide variety of frozen food and Ice creams.
  • High-energy efficient, hermetically sealed R 134 a compressor.

Optional: Voltage stabilizer of adequate capacity

SPECIFICATIONS DEEP FREEZERS


  MODEL – SPECs.                      HARD TOP
Gross Capacity - Litre                  500 Ltr
Temperature (OC)                   Temp: –18 to –26OC
HD PUF Insulation-                          60mm
CFC Free
No of Compartments                           2
No. of Doors with lock                       2
Refrigerant                         CFC Free R 134a
Body                         CRS Sheet steel - powder coated
Input – Power                 1 Ph, 180 to 260 V, AC, 50 Hz
DIGITAL CAMERA
FUNCTIONAL REQUIREMENTS:

The video cameras are intended for collecting field level clippings for projection
materials. The above items are intended to use in the six districts of Malabar
Regional Union at field level. Therefore the suppliers should be able to provide proper
maintenance support at these places for the above item.

General Specifications of Digital Camera

Digital Camera
7 to 8 mega pixels
3x to 5x optical zoom
4x digital zoom
10 MB internal memory
1 GB memory card
2 AA / Nimh rechargeable battery pack with battery charger
Additional battery set for backup
USB connection to computer
VDU cables, USB cable and all other related cables
Required software CD, operating manual etc.
Carry bag
Brand option: Nikon / Olympus / Sony / Canon
Warranty: 2 Year minimum

				