Refurbished GE RF Systems

Document Sample
Refurbished GE RF Systems Powered By Docstoc
					                                        Refurbished GE RF Systems


                                 Eastern Diagnostic Imaging
    Your Partner In Imaging

EDI Refurbishing Process
R/F Systems

All EDI Refurbished RF
Systems go through a stringent
Four Phase process to give it that                             CPI Touch Screen
like-new appearance and like-new
functionality. EDI provides 80/20
refurbishd RF systems, all
with new CPI high frequency
generators. That is, 80 percent of
the product is new components
replaced by EDI engineers and
20% is original components. New
digital fluoroscopy systems are
available as well.

Our extensive process and after                               New Digital Systems
the sale technical support is what
separates EDI from others.
EDI considers every order a
partnership between EDI, the
dealer, and the end user. Our goal
is to provide a quality solution for
your fluoroscopic imaging needs.
You can be assured an EDI
refurbished R/F system will
deliver the results you can
depend on.
Phase One: The first phase is a             Phase Three: All painted                     • During this phase of the
complete disassembly of the                 components are returned to a                   refurbishing process EDI will
major components                            staging area where the reassembly              take hundreds of exposures
                                                                                           calibrating the many different areas
• Table stripped apart to the               process begins.
                                                                                           of an RF system
  basic shell                               • Every piece of hardware is                 • Fluoroscopic function is tested
• Spot filmer stripped apart to the           replaced with new hardware                 • Digital acquisition devices installed
  basic shell                               • Every flex cable is replaced with            and calibrated per order
• Overhead Tube Crane stripped                new flex cables                              requirements
  down to its component telescopic          • Safety cables are replaced with a          • Radiographic exposures, kVp and
  parts and the bearings and bearing          new factory safety cable                     Ma stations are tested for
  guides removed                            • Safety FMI’s are installed                   compliance to the OEM
• Radiographic and fluoroscopic             • Every low voltage cable is replaced          specifications
  collimators disassembled                    with new low voltage cables                • Light to x-ray on the collimators
• Overhead Bridge for Tube Crane            • Non load-bearing bearings are              • Radiation leakage on the
  taken apart and bearing tracks              cleaned and inspected, and                   collimators
  replaced                                    replaced if required                       • Table top movement
• Longitudinal Rails cleaned and            • Load-bearing bearings are tested           • Electric locks and detents are
  new bearing tracks installed                and replaced as needed                       tested and replaced as necessary
• Chest receptor taken apart and            • Motors are tested for operational          • Calibration includes but not
  frames sent for painting                    criteria and replaced as needed              limited to:
• This overall process includes             • Spot filmer motors are tested and            kVp testing to OEM specs
  removal of every motor, bearing,            replaced as necessary                        mA testing to OEM specs
  rail, low voltage cable, high             • Potentiometers are tested and              • Filtration Checks in the collimators
  voltage cable, wire rope counter            replaced as necessary                      • Image sizing
  weight cable, to every nut and bolt       • Spot filmers are re-strung with            • Image focus
                                              new cabling                                • linearity
Phase Two: All metal components,
                                            • Collimators are completely rebuilt         • Auto brightness tracking
(table shell, and other component             and restrung for OEM specification         • System prestaging is so complete
shells) are sent to the prep and              operability                                  that when EDI completes the pre-
paint area for a sanding and                • Detents are installed and tested             stage process the system would
painting process and any                                                                   meet the rigorous pre-patient use
                                            Phase Four: After the mechanical
machining or welding                                                                       acceptance testing
                                            rebuilding and parts replacement
• Then a three part paint process                                                          of a medical physicist
                                            is completed the system is fully             • The EDI process assures all
  which includes OEM type paint
  and finish                                assembled for a system                         systems have the same high
                                            compatibility prestaging.                      quality results. It is not uncommon
                                            • It is at this time that the RF system        for end users to state
                                              is set up and run just as it is in the       “It looks brand new!”
                                              hospital or clinic it will be shipped to
                                            • Digital Spot Platforms are installed
                                              per order specifications




                                  Eastern Diagnostic Imaging

    Your Partner In Imaging
Eastern Diagnostic Imaging
300 M les y Standish Boulevard, Suite 101
Taunton, MA 02780
508-828-2970, Fax: 508-828-2973
www.easterndiagnostic.com
                                           Refurbished GE AMX-4 Portable
                                           Refurbished AMX-4                       most reliable portable on the
                                           At EDI we take pride in our             market. For over twenty years
                                           refurbishing processes. All             hospitals have relied on the
                                           AMX-4 portables have AMX-4 Plus         dependability of the GE-AMX
                                           upgrades and enhancements built         portable for their imaging needs
    Your Partner In Imaging
                                           into them, in accordance with           The EDI process guarantees that
Features                                   established standards. Each and         each AMX refurbished at the
• Structural reinforcements                every AMX goes through a                EDI facility will operate like new
• All worn and broken parts replaced       stringent process of                    and be useful for many years
• Current upgrades and FMI’s                                                       to come.
• Column +/- 270 degree rotation           refurbishing. At the end of the
• Horizontal arm rebuilt                   mechanical refurbishing every
• All bearings replaced as necessary       unit goes through a complete
• Rebuilt Base assembly                    electronic calibration in the factory
• Latch upgrade
• Upgraded Charger Board                   prior to shipping. The AMX is the
• AMX 4 Plus HV cables
• AMX 4 Plus main cables
• Noise suppressors
• Base anti-static grounding cable
• New hand switch with new cable
• Chassis reinforcement
• New collimator cable
• New rotor cable
• New Super Flex HV Cables
• Collimator rebuilt
• Cross-hair window replaced
• New arm lock
• New batteries charge cycled
• Main frame chassis reinforcement
  installed
• All bearings replaced as necessary
• New bumper pads
• New hospital grade cord cap with cord
• New 28 Amp/hour batteries
• Factory set light to x-ray calibration
• Variable speed drive calibrated
• Complete system calibration
• Complete cosmetic repairs and
  refinishing
• Complete service documentation
Technical Specifications
• High frequency generator.
• GE AMX-4 Collimator
• 100 mA constant.
• 24 kVp stations.
• kVp 50-125.
• 30 mAs stations.
• mAs 0.4-320.
• LED display.
• Rotating Anode X-Ray tube
• MX-75 275kHU Focal spot .75mm
• Variable speed motor drive
• Electric solenoid locks

Eastern Diagnostic Imaging
300 Myles Standish Boulevard, Suite 101
Taunton, MA 02780
508-828-2970, Fax: 508-828-2973
www.easterndiagnostic.com
                                                          Experience the Freedom – Go Wireless
                                                          with the eVision   Mobile DR Conversion kit from EDI

                                     Upgrade your AMX-4 or AMX-4+ to            Now, eVision Mobile DR will free
                                     wireless DR Today. The time is right       you from tethered DR solutions. No
                                     to complete your DR conversion!            more wires to tangle! Simply posi-
                                     The technology of InfiMed, and EDI         tion the patient, place the wireless
                              Eastern Diagnostic Imaging
                                     have come together to create the           casette and GO, with results in a
    Your Partner In     Imaging
                                     perfect solution.                          matter of seconds.


Wireless DR Technology
The Wireless DR Flat Panel Detec-
tor allows the technologist the ease
and quickness of DR imaging with-
out the hassle of a tethered panel.
With a wireless DR solution, it’s just
like using a standard film cassette,
only much faster!
Improved Workflow
The eVision Mobile DR solution
provides results in less than 10 sec-
onds, thus allowing the technologist
to complete the work faster, and
the radiologist to see the
images immediately.
Highest Quality Imaging Available
Wireless DR Flat Panel Detector and
the InfiMed i5 software technology
offer the best DR imaging in the
market today. High quality DR
Images are available for review
in seconds!
Advantages
•	InfiMed i5 DR Software
•	InfiMed product support team
•	Wireless	DR	Flat	Panel	Detector
•	Custom	designed	insert	for	
  cassette drawer To hold the Flat
  Panel Detector, extra battery,
	 and	Tablet	PC
•	Custom	designed	top	cover	for	
  AMX-4 portable
•	Tablet	PC	for	ease	of	use	and	to	
  complete the Wireless experience
                                                          Experience the Freedom – Go Wireless
                                                          with the eVision   Mobile DR Conversion kit from EDI



Wireless DR Detector Panels have
established a new standard for
portable imaging.
Standard Kit includes:
•	New	top	cover	for	AMX-4	portable	unit.	
•	Tablet	PC	that	easily	stores	in	the	
  cassette drawer, loaded with the
  new i5 software from InfiMed.
•	New	Wireless	Flat	Panel	
  DR Detector
•	Easy	to	install	instructions
•	The	best	technical	support	
  team in the business
Tablet PC Specifications:
•	Dual	Core	1.5	Ghz	Speed	processors
•	80	Gb	Disk	drive
•	2Gb	RAM
•	Stores	up	to	10,000	images
•	Wireless	modem
•	Ethernet	connection	to	PACS,	
  HIS/RIS Systems
Wireless DR Flat Panel Detector
Wireless cassette-sized detector,
ISO 4090
•	Wireless	standard	802.11	n
•	Image	size:	35	x	43	cm
•	Maximum	external	dimensions:	
  same	as	35	x	43	cm	cassette
•	Weight:	8.5	lbs	(3.9	kg)
•	Pixel	pitch:	139	m
•	Power:	On-board	rechargeable	
  battery or external battery charger
•	Captures	70	to	90	images	on	a	
  single charge
Battery charger
•	Accommodates	up	to	three	
  batteries for recharging
•	Power:	90–264	V,	50–60	Hz,	75	W	max




                                  Eastern Diagnostic Imaging
    Your Partner In Imaging
Eastern Diagnostic Imaging
300 Myles Standish Boulevard, Suite 101
Taunton, MA 02780
508-828-2970, Fax: 508-828-2973
www.easterndiagnostic.com
                          Refurbished OEC 9600 C-arm
                          OEC 9600 C-arm                          when doing needle localizations
                          Refurbishing Process                    or other work involving the thicker
                          All OEC-9600’s go through a             anatomical areas of patients. For
                          multi-step refurbishing                 barium swallows a VCR or Digital
                          process. EDI takes great pride in       Video Recorder can be utilized for
Your Partner In Imaging
                          the fact that each unit is restored     better record keeping and post
                          to a like-new status. Pain              study analysis. The CCD
                          Management, Orthopedics,                Technology used in the OEC-9600
                          Rehabilitation Services are just a      image system allows for crisp
                          few of the applications utilizing the   clear imaging. Whatever the
                          EDI refurbished OEC-9600 carm.          purpose, an EDI refurbished
                          The rotating x-ray tube allows          OEC-9600 will deliver the results
                          for greater penetration and             you can depend on.
                          resolution for the lumbar area
Mechanical repairs/cosmetic               Re-assembly                              Technical Specificaitons
maintenance                               • All components sent to C-arm           Generator
• All defective parts and covers are        reassembly area for rebuilding         • High frequency generator 4.0 KW
  repaired or replaced                    • “C”, Image tube and camera,              full-wave
• C-arm is completely disassembled          Vertical column, main control and      • Up to 120 KVP and 75MA for
  and repainted                             power cable installed                    radiographic exposures
• “C” is removed from main frame          • New batteries are installed            • Continuous fluoro-mode up
  assembly                                • New CRT monitors installed in            to 5MA
• Horizontal arm removed, inspected         monitor cart                           • One shot frame integration (low,
  and repaired as necessary               • Monitor cart rebuilt                     medium, high)
• Vertical column removed and             • When C-arm is completely rebuilt       • Full power from standard 110V
  bearings removed inspected and            mechanically, system is sent for         15A Or 220V 8A outlet
  replaced as required                      calibration and final testing          • Patented energy buffer design
• X-ray tube removed and inspected        Testing/calibration                        X-Ray Tube
  for artifacts and internal integrity    • Image intensifier and X-ray tube       • Rotating anode X-ray tube
• Image intensifier removed and             are tested for stability and balance   • Focal spots: 0.3 - 0.6 mm
  inspected for any imperfections         • Image intensifier is tested for        • 300,000 HU Anode heat capapcity
  and grid integrity                        resolution and gain to be within       Physical Specificaitons
• Camera removed                            OEM specifications                     • Free Space in Arc - 31”
• Wheels removed, cleaned and or          • X-ray tube bearings are tested for     • Depth of Arc: 26”
  replaced from main chassis                noise and coast time                   • Arc orbital movement: 115 Degrees
• Chassis inspected for structural        • X-ray tube filaments and stator        • Left/Right wig-wag scan: +/- 11
  defects and repaired as necessary         windings are tested                      degrees
• Vertical lift assembly is tested for    • X-ray tube radiation output is         • Vertical Travel: 18” motorized
  drift and adjusted/replaced if            verified to be within OEM              • Horizontal travel: 8”
  necessary                                 specifications                         • L-arm rotation: +/- 180 degrees
• All bearings are inspected, cleaned     • X-ray generator high voltage tested
  and re-lubricated, or replaced as                                                C-arm Dimensions
                                          • Maximum dose rate is set in            • Length: 78.5”
  needed                                    compliance with government
• Control panel display is tested and                                              • Height 68.25”
                                            regulations                            • Width: 33”
  replaced if necessary                   • CCD camera calibrated to OEM
• All wheels are inspected and                                                     Workstation Dimensions
                                            specifications                         • Width: 27.25”
  lubricated and/or replaced as           • X-ray beam is aligned for each
  needed, with new cable pushers                                                   • Height 68.25”
                                            field size                             • Depth: 27.25”
  installed                               • C-arm is tested for current leak-
• All locks and brake assemblies are        age requirements
  inspected, cleaned, and repaired        • All monitors are aligned, resized,
  or replaced as needed                     centered and focused
• C-arm is completely disassembled        • All monitors are adjusted for
  and repainted                             brightness and linearity
• Steering is tested and adjusted as      • Video system is optimized for gray
  required                                  scale and resolution
• Foot switch and hand switch             • All power supplies are tested and
  provided on each unit                     calibrated or replaced as
• A complete set of operator and            necessary
  service manuals are provided




                                 Eastern Diagnostic Imaging

    Your Partner In Imaging
Eastern Diagnostic Imaging
300 Myles Standish Boulevard, Suite 101
Taunton, MA 02780
508-828-2970, Fax: 508-828-2973
www.easterndiagnostic.com
                                  Refurbished OEC 9800 C-arm
                          OEC 9800 C-arm                        when doing needle localizations
                          Refurbishing Process                  or other work involving the thicker
                          All OEC-9800’s go through a           anatomical areas of patients. For
                          multistep refurbishing                barium swallows a VCR or Digital
                          process. EDI takes great pride in     Video Recorder can be utilized for
Your Partner In Imaging
                          the fact that each unit is restored   better record keeping and post
                          to a like-new status. Pain            study analysis. The 1K X 1K CCD
                          Management, Orthopedics and           Technology used in the OEC-9800
                          Rehabilitation Services are just a    image system allows for crisp,
                          few of the applications utilizing     clear imaging. Whatever the
                          the EDI refurbished OEC-9800          purpose, an EDI refurbished
                          c-arm. The rotating x-ray tube        OEC-9800 will deliver the results
                          allows for greater penetration        you can depend on.
                          and resolution for the lumbar area
Mechanical repairs/cosmetic               Re-assembly                              Technical Specificaitons
maintenance                               • All components sent to C-arm           Generator
• All defective parts and covers are        reassembly area for rebuilding         • High frequency generator 15kW
  repaired or replaced                    • “C”, Image tube and camera,              full-wave
• C-arm is completely disassembled          Vertical column, main control and      • Up to 120 KVP and 75MA for
  and repainted                             power cable installed                    radiographic exposures
• “C” is removed from main frame          • New batteries are installed            • Continuous fluro-mode up to 20 mA
  assembly                                • New CRT monitors installed in          • One shot frame integration (low,
• Horizontal arm removed, inspected         monitor cart                             medium, high)
  and repaired as necessary               • Monitor cart rebuilt                   • Full power from standard 110V
• Vertical column removed and             • When C-arm is completely rebuilt         15A Or 220V 8A outlet
  bearings removed inspected and            mechanically system is sent for        • Patented energy buffer design
  replaced as required                      calibration and final testing            X-Ray Tube
• X-ray tube removed and inspected        Testing/calibration                      • Rotating anode X-ray tube
  for artifacts and internal integrity    • Image intensifier and X-ray tube       • Focal spots: 0.3 - 0.6 mm
• Image intensifier removed and             are tested for stability and balance   • 300,000 HU Anode heat capapcity
  inspected for any imperfections         • Image intensifier is tested for        Physical Specificaitons
  and grid integrity                        resolution and gain to be within       • Free Space in Arc - 31”
• Camera removed                            OEM specifications                     • Depth of Arc: 26”
• Wheels removed, cleaned and or          • X-ray tube bearings are tested for     • Arc orbital movement: 115 Degrees
  replaced from main chassis                noise and coast time                   • Left/Right wig-wag scan:
• Chassis inspected for structural        • X-ray tube filaments and stator          +/- 20 degrees
  defects and repaired as necessary         windings are tested                    • Vertical Travel: 18” motorized
• Vertical lift assembly is tested for    • X-ray tube radiation output is         • Horizontal travel: 8”
  drift and adjusted/replaced if            verified to be within OEM              • Lateral rotation: +/- 180 degrees
  necessary                                 specifications
• All bearings are inspected, cleaned                                              C-arm Dimensions
                                          • X-ray generator high voltage tested    • Length: 75.9”
  and re-lubricated, or replaced as       • Maximum dose rate is set in
  needed                                                                           • Height 69.9”
                                            compliance with government             • Width: 33”
• Control panel display is tested and       regulations
  replaced if necessary                                                            Workstation Dimensions
                                          • CCD camera calibrated to OEM           • Width: 27”
• All wheels are inspected and              specifications
  lubricated and/or replaced as                                                    • Height 64”
                                          • X-ray beam is aligned for each         • Depth: 27”
  needed, with new cable pushers            field size
  installed                               • C-arm is tested for current leak-
• All locks and brake assemblies are        age requirements
  inspected, cleaned, and repaired        • All monitors are aligned, resized,
  or replaced as needed                     centered and focused
• C-arm is completely disassembled        • All monitors are adjusted for
  and repainted                             brightness and linearity
• Steering is tested and adjusted is      • Video system is optimized for gray
  required                                  scale and resolution
• Foot switch and hand switch             • All power supplies are tested and
  provided on each unit                     calibrated or replaced as
• A complete set of operator and            necessary
  service manuals are provided




                                 Eastern Diagnostic Imaging

    Your Partner In Imaging
Eastern Diagnostic Imaging
300 Myles Standish Boulevard, Suite 101
Taunton, MA 02780
508-828-2970, Fax: 508-828-2973
www.easterndiagnostic.com

				