Zip Hydroboilо Over-sink instant boiling water for busy kitchens

Document Sample
Zip Hydroboilо Over-sink instant boiling water for busy kitchens Powered By Docstoc
					                                    ®
Zip Hydroboil                                                                                      Over-sink instant boiling water
                                                                                                                for busy kitchens
                                                                                                                          1.5 litre, 3.0 litre, 5.0 litre, 7.5 litre

                                                 Capacity     Delivery        Recovery Energy rating                             Dimensions (mm)
                  s/steel          white            litres  cups* at a time cups per hour (kW @ 230V AC)      A      B     C    D          E     F      G       H     J   K
             ®
Zip Hydroboil        –            HS001           1.5 litre        9            100              1.5         335    289   180   20        163   95     198      35   25   42
             ®
Zip Hydroboil        –            HS003           3.0 litre       18            100              1.5         431    289   180   20        163   95     198      35   25   42
             ®
Zip Hydroboil     HS105           HS 005          5.0 litre       30            140              2.4         465    318   198   20        163   95     198      35   25   42
             ®
Zip Hydroboil     HS107           HS 007          7.5 litre       45            140              2.4         578    318   198   20        163   95     198      35   25   42
* Standard cup size: 167ml

• Twin chamber instant boiling water heater.                   Outer Case                                            For concealed plumbing connections, connect
                                                               Stainless steel or corrosion-resistant, white         inlet and vent pipes from the rear via 15 mm
• Provides water within 1˚C of boiling point.
                                                               enameled steel                                        capillary elbows
• Separates the cold water supply from the
                                                               Insulation                                            For exposed plumbing connections, connect inlet
  boiling chamber.
                                                               Compressed high temperature insulation panels         and vent pipes from the bottom directly
• Internal condensing system retains steam                     engineered for quick access to boiling chamber        to 15 mm compression fittings with nuts and
  within the heater.                                           ports                                                 olives provided
• Stainless steel boiling chamber with service                 Safety features                                       Venting
  access ports top and bottom.                                 Thermal cutout integral to heating element;           The vent must discharge to a safe visible position
                                                               thermal cutout on vent tube                           as, under certain conditions, the vent may
• Temperature controls automatically cut off the
                                                                                                                     discharge cold or boiling water and/or steam
  power in the event of temperature control                    Approvals
  failure, boil dry cutout or a blocked vent pipe.             WRAS and CE endorsed                                  The vent pipe outlet must be connected via a
                                                                                                                     tundish to a 15 mm copper vent pipe which has
• High temperature thermal insulation with                     Installation
                                                                                                                     a continuous fall, is no more than 3 metres long,
  provision for service access to the boiling
                                                               Location                                              and has no more than 3 right angle bends
  chamber.
                                                               Should be installed over a draining board, or over
                                                                                                                     The bug screen supplied must be fitted to the
• Electronic temperature control.                              a work top fitted with a drip tray – tap spout
                                                                                                                     end of the vent tube
                                                               should be no higher than necessary to
• Tap is cool to the touch when dispensing
                                                               fill large pots                                       Electrical
  boiling water.
                                                                                                                     To be wired to a double pole fused spur, minimum
                                                               Minimum tap height above draining board for on-
• Ready-to-use status indicator and filter                                                                           break rating of 13 amp
                                                               wall maintenance is 200 mm
  replacement status (if filter fitted) indicator.
                                                                                                                     For concealed electrical connection, connect
                                                               Leave minimum clearance of 150mm above,
• Concealed plumbing                     and     electrical                                                          a fixed or flexible cable from the rear directly
                                                               65mm left and 20mm right
  connections.                                                                                                       to the terminal block
                                                               Hanging and       fixing screws supplied with
Heating element                                                                                                      Installation must comply with current IEE
                                                               wall plugs
Long-life incalloy sheathed embedded rod                                                                             regulations
                                                               Plumbing
Thermostat                                                                                                           Caution
                                                               Designed for direct connection to a potable cold
Capillary type                                                                                                       In some hard water areas where mineral
                                                               water supply with a minimum pressure of 1 bar
                                                                                                                     scale accumulation can become a problem,
Boiling chamber                                                and a maximum pressure of 7 bar
                                                                                                                     consideration should be given to the maintenance
Crevice-free stainless steel chamber with
                                                               A pressure reducing valve must be installed if        required
removable stainless steel access ports top and
                                                               water supply pressure is likely to exceed 7 bar
bottom                                                                                                               Technical advice
                                                               An isolating valve should be installed between        Contact Zip on 0870 608 8888
                                                               the water supply and the heater




       Dimensions                                                                Typical installation                         Minimum clearances (mm)

                                                                                  Exposed
             C                                     B
                                                   G

                             D                                                    Electrical
                                                                                  wiring


                                                                                                Tundish                              65                    20

                                                               A


                        E                H                                                                                                           200
                                                                                     Service
                                                        J                            valve
                    F
                                                                                     Cold
                                             K                                       water
                                 Cold                                                supply     To drain
                                 water
                                 inlet           Vent



01.09.06


Zip Heaters (UK) Ltd. 14 Bertie Ward Way, Dereham, Norfolk NR19 1TE

				