					POWERCELL PDX




            POWERCELL PDX
              Vehicle Terminals
                  Overview
Agenda

   POWERCELL PDX Advanced Diagnostics
   PDX Supporting Vehicle Scale Terminals
     - IND780
     - IND560 PDX
   MTX Migration and Terminal Phase Out




                             1
What a Distributor Needs from a Truck Scale

                          Lower installation costs
                          Lower maintenance cost
                             - Faster ways to find and fix
                                 problems
                             -   Convenient maintenance
                                 scheduling
                          Service revenue opportunities
                             - Enhanced service offerings
                             - Protected service
                          Customer satisfaction
                             - Repeat business




                     2
 What a Customer Needs from a Truck Scale
  Accurate weight every time
  Reliable operation all the time
  Reduced maintenance expense
     -   Predictable maintenance expense
  Not to spend more money than
   necessary




Most customers need their scale working 100%
                                           3
The Complete Solution
 IND780 and IND560 PDX bring the power of
  POWERCELL PDX to life
   - Advanced and Predictive maintenance tools
   - Alerts and alarms
   - Collection and storage of scale performance history
   - Scale performance report
   - Protected services




                                      4
POWERCELL PDX 
   Accurate Weight               Temperature Deviation
   Date                          Current Temperature
   Time                          Max Temperature
   Node Address                  Min Temperature
   S/N                           Gas Concentration
   Cell Counts                   Energy Deviation
   COM Errors                    Current Energy
   Min Supply Voltage            Zero Drift Errors
   Supply Voltage                Zero Drift Value
   CAN-H Voltage                 Cell Overloads
   CAN-L Voltage                 Average Overload Weight
   Major over-voltage/current    Symmetry Errors
   Major under-voltage           Symmetry Difference
   Minor over-voltage/current
   Minor under-voltage
   Total Transactions


                                           5
PDX Diagnostic Data in IND780 & IND560 PDX

         History of Data                       Supply Voltage




   Temperature                                                  Communication
                                                                 Signal Voltage




                           Gas Concentration




                                   6
   Why these Features are Important
                     Communication     Supply Voltage   Gas Concentration   Temperature
History of Data       Signal Voltage




   Emergency Situation
       - Find and Fix the problem quickly
             Save customer time and money
             Save technician time
   Typical Preventative Maintenance Service Call
       - Discover problems before a failure
             Schedule Service at convenient times
             Better control of your service scheduling


                                         7
Diagnostics at the Terminal Interface
Predictive Diagnostics for Network Health




                                8
IND780 Web Server Information




                    9
PDX Performance Log
 Provides a summary of performance and diagnostics information regarding the
  PDX scale system.
   - Live counts and total scale transaction.
   - Cell com, zero drift, symmetry, overload, over/under-voltage fault counters.
   - Cell CAN bus and supply voltage levels.
   - Cell temperature and gas concentration.
 Real Customer savings
   - Faster diagnosis = Minimize profit loss from downtime
   - Spot future problems = Convenient maintenance times
   - Save report in PC = Easily keep records




                                      10
Multiple Levels of Alarm Actions
Know about a problem before it becomes big

 Email alerts for fast communication of key conditions
   - multiple addresses
   - including service provider
 Alerts displayed on terminal
 Shut Down – if you decide a condition would
  affect your operation
    - optional in setup




                                       11
Protected Services

MT Service Security
 Used to unlock or lock access to the PDX diagnostics
  data and the MT Service View.
 Authorized version of InSite needed to provide the
  Key String to unlock the terminal.
 IND780 and IND560 PDX automatically lock after a
  period of time




                                       12
Unlocking Maintenance Features with InSite v5




                       13
Viewing the Performance Log




                    14
Saving Maintenance Data with InSite v5




                    15
How Do I Choose?




                   16
Questions to Help Qualify the Opportunity

   New, retrofit or upgrade opportunity
   # of cells
   Multi-platform or multi-axel application
   Display (HMI)
   Communication and peripheral equipment needs
   Specialized Applications
     - Control of loops lights gates
     - Multi-axle weighing
     - Filling
 Hazardous location classification
 Services
     -   Alarms and alerts
 Cost


                                           17
Lightening Protection
Special circuitry in both terminals provides protection for severe conditions!
IND780 PDX
 Lightning Protection tested to 82,000 Amps

IND560 PDX
 Lightning Protection tested to 40,000 Amps
 2 electrically isolated serial ports




                                     18
New, Retrofit or Upgrade



        Installation                       IND780         IND560 PDX
New POWERCELL PDX
truck scale*

MTX Terminal Retrofit

MTX to PDX Upgrade

 * # of cells, decks and distances are limiting factors




                                             19
# of Cells
             IND780

                           Internal 12V

                          80m Home Run

                                                      14 cells
                                                100m cell to cell cable



         Unique model in IND560 family



IND560 PDX
              Internal 24V

              275m Home Run

                                                     14 cells
                                               130m cell to cell cable

                                          20
# of Cells and Decks
Scale 1

Scale 2          More than 14 cells?
                 Multiple scales?
Scale 3
                 Multi-axel?
Scale 4




 IND780

               300m Home Run (total)




          External 24V




                                                       24 cells
                                            200m cell to cell cable (total)
                                       21
HMI
  IND780
     Full diagnostic ¼ VGA display
     Color available
     5 softkeys
     Application keys




  IND560 PDX
   Bright vacuum fluorescent display
      - 45mm total
      - 21mm weight
   5 softkeys

                                      22
Communications & Peripheral equipment
           IND780
                             Standard:                 Options:
                                  -   Ethernet             -   2 serial ports
                                  -   USB Master           -   PLC interfaces
                                  -   2 serial ports       -   Discrete I/O




                     Standard:
  IND560                -   2 electrically isolated
                            serial ports standard
                     Options:
                        -   NEW Ethernet/USB/Serial
                            option
                        -   Ethernet/Dual serial
                            option available
                        -   PLC interfaces
                        -   Discrete I/O

                                              23
Specialized Applications
IND780                                          IND560 PDX
 Drive-780 advance vehicle software             Drive-560 simple vehicle software
     -   Traffic control – lights, gates             -   No I/O control
   Axle-780                                       Fill-560
   Legacy COMs                                    Legacy COMs
   Task Expert Option                             Task Expert Option
   Interface with OverDrive®                      Interface with OverDrive®




           Fast/precise Filling            24
                                                    Accurate Coupled in Motion
Hazardous Area Use

IND780
 ATEX Zone 2, Zone 22
 FM Division 2
   - POWERCELL PDX option board pending


IND560 PDX
 No approvals for hazardous areas




                                     25
Alarms and Email Alerts
On Screen Alerts
 Both terminals displayed alerts on screen
                                                       IND780


Email Alerts
 IND780 email alerts for multiple error and failure
  conditions
    - Including PDX specific errors
 IND560 PDX limited to calibration events

Critical Error Management
                                                       IND780
 IND780 can shut down a scale if error condition is
  severe enough to affect operation
    - Option in IND780 setup
 IND560 PDX can disable scale on calibration
  expiration only



                                        26
Changing Product Line

                         Automatic




                                                IND780



                                       IND560
  Weight only                                            Application
                               OverDrive




                                                IND310




                IND135
                          Manual

                          27
                               27
Vehicle Terminals – Alternate Scenario


 By mid-2010 60% of North American POWERCELL
  sales anticipated to be PDX




 Phase-out IND135 in mid-2010
   - CIM and Unattended being re-qualified with
     IND780 and IND560 PDX



 IND310 in product line through Q2 2011
    - Launch IND780 TR and IND246 vehicle in Q1 2011




                                     28
Proposed IND780 TR

 Concept
   - De-featured IND780 monochrome harsh with Drive-780
   - Sold at current IND310 list price
   - MTX or analog
        use current scale pcbs
   -   Different firmware load then standard IND780
 Available Options:
   - DIO pcb
   - Serial option pcb
 Approvals
   - Same UL, NTEP, OIML as current IND780




                                      29
Proposed IND246 - Low End Analog
 Features
   - Backlit alpha-numeric LCD display
   - 21 function and numeric keys
   - 6 – 350ohm analog load cells
   - OIML 6000e / NTEP 10000d
   - +5V/ +10VDC excitation voltage
   - One RS-232 serial port
   - IP65

 Options:                                Functions
   - Ni-MH rechargeable battery             - Stored tare table
   - RS485                                  - Auto-assign ID
   - 3 inputs / 5 outputs                   - Alibi Memory
   - Ethernet                               - Totalization by ID
   - USB
   - WiFi wireless
                                    30

				