Docstoc

BROADBAND LINEAR AMPLIFIER Model P200

Document Sample
BROADBAND LINEAR AMPLIFIER Model P200 Powered By Docstoc
					                 ELECTRONICS AB                                            WWW.FLCE.SE




                BROADBAND
LINEAR
AMPLIFIER
                                  Model
P200





      HIGH
VOLTAGE
                     GAIN
               HIGH
CURRENT

            ±100V
                       10x
                     1
A


             HIGH
                     POWER
               SMALL
SIGNAL

         SLEW
RATE
                BANDWIDTH
                BANDWIDTH

           20
V/µs
               DC
to
ca
50
kHz
          DC
to
>200
kHz




        FLC Electronics AB        Tel. +46 31 741 2631   VAT No. SE556506606401
         Sippedalsvägen 8         Fax +46 31 44 61 10       Email flce@flce.se
    S - 433 31 Partille, Sweden   Fax +46 31 41 75 30       Web http://flce.se
              ELECTRONICS AB                                                 WWW.FLCE.SE




GENERAL
DESCRIPTION

The P200 is a general purpose linear amplifier with high voltage and high output current.
Intended applications are piezoelectric positioning, electrostatic transducers and other
high voltage instrumentation.

The P200 amplifier has a fixed gain of x10 and the input resistance of 1 MΩ The input
amplitude should be within -10…+10 V giving output voltage in the range -100…+100V.
Higher input voltage will be limited to -10…+10 V range by the input protection circuit.
Above ca 300% overvoltage an input microfuse might be blown (a spare fuse is provided
on the amplifier’s printed-circuit board).

The maximum power dissipation of the amplifier is 125W and the maximum output
current is ca 1A. The slew rate is ca 20 V/µs.


I M P O R TA N T 
 N OT E S

Due to the high dissipated power the amplifier requires good ventilation. Air intake (at
the bottom of the case) and the fan (on the back) should never be obstructed.

The instrument cannot be powered from a DC-AC converter nor from a solid-state AC
generator with non-sinusoidal output.

Inside the amplifier case exist dangerous voltage levels.

Never connect the output to the input of the amplifier! The input fuse will be blown
immediately.


LO A D

P200 is designed for mainly resistive and capacitive load. Please avoid inductive load.




P200                                                                                 page 1
              ELECTRONICS AB         WWW.FLCE.SE




F R EQ U E N C Y 
 R E S P O N S E




P200                                       page 2
             ELECTRONICS AB                                               WWW.FLCE.SE




                   S U M M A RY 
 O F 
 T E C H N I C A L 
 DATA

Bandwidth:                         DC to about 50 kHz at 200 Vpp
Small signal bandwidth:            DC to >200 kHz
Amplification:                     10 times fixed
Load:            type              resistive || capacitive
Impedance:       input             1 MΩ || <30 pF
                 output            1 Ω in the linear mode
Voltage:         input             maximum ±10 V
Current:         output            maximum 1 A
Slew Rate:       output            ca 20 V/µs at 50 Ω load
Input protection fuse              15 mA (Littelfuse, part number 272.015)
                                   one spare fuse provided inside the instrument,
                                   additional fuses available from Littelfuse
                                   resellers or from FLC Electronics AB.


Operating Ambient Temperature:     0°C to 30°C
Storage Temperature:               0°C to 60°C
Relative Humidity:                 up to 90% (operation)
                                   30% to 50% (storage)
Power Requirements:                100/110 V or 220/230 V, 50/60 Hz
Fuse:                              100/110 V: 3.15 A (slow),
                                   220/230 V: 2 A (slow)
Dimensions (H/W/L):                112 x 255 x 316 (mm)
Weight:                            5 kg
Country of Origin:                 Sweden




N ot e: Specifications apply to instruments operating at 23°C±5°C ambient temperature
after 15 min. warm-up time. Due to ongoing product development, specifications are
subject to change without notice.

WA R NING It is not allowed to connect the 100...230V AC line power input of the
amplifier to DC-AC converters or solid state AC generators with non-sinusoidal output.




P200                                                                                page 3
              ELECTRONICS AB                                                   WWW.FLCE.SE




WA R R A N T Y
F LC E lectronics war rants that this product will be free from defect s i n
m a t e r i als and workmanship for a period of two years from the dat e o f
t h e s h i p ment.

If any such product proves defective during this warranty period, FLC Electronics, at its
option, either will repair the defective product without charge for parts and labour, or will
provide a replacement for the defective product. In order to obtain service under this
warranty, Customer must notify FLC Electronics of the defect before the expiration of
the warranty period and make suitable arrangements for the performance of the service.
Customer shall be responsible for packing and shipping the defective product to the
service center designed by FLC Electronics, with shipping charges prepaid. FLC
Electronics shall pay for the return of the product to the Customer if the shipment is to a
location within the country in which the FLC Electronics service center is located.
Customer shall be responsible for paying all shipping charges, duties, taxes, and any other
charges for products returned to any other locations.

This warranty shall not apply to any defect, failure or damage caused by improper use or
inadequate maintenance and care. FLC Electronics shall not be obligated to furnish
service under this warranty:
• to repair damage resulting from attempts by personnel other than FLC Electronics
  representatives to install, repair or service the product;
• to repair damage resulting from improper use or connection to incompatible
  equipment;
• to service a product that has been modified or integrated with other products when the
  effect of such modification or integration increases the time or difficulty of servicing
  the product.

This warranty is given by the FLC Electronics with respect to this product in lieu of any
other warranties, expressed or implied. FLC Electronics and its vendors disclaim any
implied warranties of merchantability or fitness for a particular purpose. FLC
Electronics’ responsibility to repair or replace defective products is sole and exclusive
remedy provided to the customer for breach of this warranty. FLC Electronics and its
vendors will not be liable for any indirect, special, advance notice of the possibility of
such damages.

The instrument may generate hazardous voltage levels! It should be operated by qualified
personnel only. The instrument is to be used in normal room temperature and humidity.

The manufacturer cannot be held responsible for damage to any device connected to the
instrument. It is recommended that samples or equipment sensitive to voltage spikes are
disconnected from the high-voltage outputs when turning the power to the instrument
ON or OFF.




P200                                                                                  page 4
       ELECTRONICS AB                                       WWW.FLCE.SE




                    I M P O R T A N T


          Inside the amplifier case exist dangerous voltage levels.



       The instrument cannot be powered from a DC-AC converter
        nor from a solid-state AC generator with non-sinusoidal
                                output.



       Loads sensitive to voltage transients should be disconnected
         from the amplifier during power-up and power-down.




          Never connect the output to the input of the amplifier!




          The amplifier may be overheated if the output is short-
                        circuited for a long time.


          The maximum allowable capacitive load depend on the
        internal setting of the slew rate. Overloading the output is
           likely to cause overshoot. Slow down the amplifier to
                         accommodate a larger load.


          It is recommended to monitor the output signal of the
                      amplifier on the oscilloscope.




P200                                                                  page 5
              ELECTRONICS AB                                                      WWW.FLCE.SE




                           EC Declaration of Conformity



We

        FLC Electronics AB
        Sippedalsvägen 8
        SE-43331 Partille
        Sweden



declare under sole responsibility that the

                                 Voltage Amplifier P200

meets the intent of Directive 89/336/EEC for Electromagnetic Compatibility (EMC) and
Low Voltage Directive 73/23/EEC (LVD). Compliance was demonstrated to the
following standards as listed in the official Journal of the European Communities:



       EN 50081-1
           Generic Emissions
       EN 55022
             Conducted emission (interference voltage), class B
       EN 55022
             Radiated emission (electric field), class B

       EN 50082-1
           Generic Immunity
       EN 61000-4-4
         Electrical fast transient/burst
       EN 61000-4-2
         Electrostatic discharge
       EN 61000-4-3
         Radiated E-fields (radio frequency)

       EN 61010-1:2001
      Electrical Safety




                                                     Tomasz Matuszczyk, PhD
                                                        Technical Director
                                                       FLC Electronics AB
December 14, 2006




P200                                                                                    page 6

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:11
posted:9/27/2011
language:English
pages:7