Docstoc

Slide 1 - Life-Tech

Document Sample
Slide 1 - Life-Tech Powered By Docstoc
					                              Distributor Training Module 15




Life-Tech



            Ministim MS-IVA
                                   Distributor Training Module 15




Life-Tech
               This module consists of a sequence
               of multimedia slides and will take
               approximately 5 minutes to review.

               It is anticipated that you have
               already viewed the Basics of Nerve
               Stimulation module.

               If you have not done so it is
               recommended that you do so before
               continuing with this presentation.




            MiniStim MS-IVA
                                    Distributor Training Module 15




Life-Tech
               By the end of this module you will
               understand:

               -The characteristics of the Life-Tech
               MinStim MS-IVA

               -Accessories available for the
               MiniStim MS-IVA




            MiniStim MS-IVA
                              Distributor Training Module 15




   MiniStim MS-IVA

   The MiniStim® MS-IVA peripheral nerve
   stimulator can be used for neuromuscular
   monitoring in operating room, post anesthesia
   care and critical care environments.




MiniStim MS-IVA
                                Distributor Training Module 15




   MiniStim MS-IVA

   The stimulator is certified to function in the
   presence of electrosurgery equipment and the
   electrosurgical procedures, providing that the
   electrosurgery site is at least 1 foot (30cm) from
   the stimulator patient lead connection point.




MiniStim MS-IVA
                          Distributor Training Module 15




   MiniStim MS-IVA

   • Cost-effective
   • Simple to use
   • Durable & reliable
   • Compact design




MiniStim MS-IVA
                               Distributor Training Module 15




   MiniStim MS-IVA

       Output Stimulus Pulse/Open Lead Indicator


       The Output Stimulus Indicator flashes each
       time current passes through the patient.

       Conditions such as open lead or electrode
       will prevent the indicator from flashing thus
       alerting the operator.




MiniStim MS-IVA
                              Distributor Training Module 15




   MiniStim MS-IVA

       Power/Battery Indicator


       Lights when unit is on.
       Flashes when it is time to replace the
       battery.




MiniStim MS-IVA
                              Distributor Training Module 15




   MiniStim MS-IVA

       50 kHz Key


       Press and hold for Tetanus at 50 pulses
       per second




MiniStim MS-IVA
                             Distributor Training Module 15




   MiniStim MS-IVA

       100 kHz Key

       Press and hold for Tetanus at 100 pulses
       per second




MiniStim MS-IVA
                              Distributor Training Module 15




   MiniStim MS-IVA

       Double Burst Key

       Press and release for double burst
       stimulation

       Each Double Burst stimulus consists of two
       groups of 3 pulses each.

       Within a group, the individual pulses are
       separated by 20ms (5oHz rate); the
       second group of three pulses follow the
       first after 750 ms.




MiniStim MS-IVA
                               Distributor Training Module 15




   MiniStim MS-IVA

       Train of Four Key

       Press and release for train of four
       stimulation

       Two pulses per second for to seconds




MiniStim MS-IVA
                               Distributor Training Module 15




   MiniStim MS-IVA

       Twitch Key

       Press and release for twitch stimulation.

       Unit automatically repeats twitch (one
       pulse per second) until turned off or until
       DBL BURST or TRAIN OF FOUR button is
       pressed.




MiniStim MS-IVA
                              Distributor Training Module 15




   MiniStim MS-IVA

       Belt/Pocket Clip

       Use to attach instrument to clothing




MiniStim MS-IVA
                              Distributor Training Module 15




   MiniStim MS-IVA

       Battery Access Door

       Slide open to replace battery




MiniStim MS-IVA
                              Distributor Training Module 15




   MiniStim MS-IVA

       Stimulus Amplitude Control Dial

       Rotate clockwise to increase stimulus
       current




MiniStim MS-IVA
                                Distributor Training Module 15




   MiniStim MS-IVA

       Output Jacks

       Two touch proof connectors for probes and
       leads.

       Red jack is positive

       Black jack is negative




MiniStim MS-IVA
                            Distributor Training Module 15




   MiniStim MS-IVA
      Accessories

   Bipolar ball probes DP-MTP




MiniStim MS-IVA
                               Distributor Training Module 15




   MiniStim MS-IVA
       Accessories

   Extension Leads EL-2MTP

   Two foot long paired leads with touch proof
   connectors at one end and alligator clips at the
   other.




MiniStim MS-IVA
                                   Distributor Training Module 15




Life-Tech
               You should now understand:

               -The characteristics of the MiniStim
               MS-IVA

               - The types of available accessories
               for the MiniStim MS-IVA




            MiniStim MS-IVA
                             Distributor Training Module 13




Life-Tech



            MiniStim MS-1B

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:12
posted:9/25/2011
language:English
pages:21