DOMUS Doors by stariya

VIEWS: 11 PAGES: 5

									L20    DOORS / SHUTTERS / HATCHES

       To be read with Preliminaries / General Conditions

       GENERAL

110    EVIDENCE OF PERFORMANCE
   -   Certification: Provide independently certified evidence that all incorporated
       components comply with specified performance requirements.

150    SITE DIMENSIONS
   -   Procedure: Before starting work on designated items take site dimensions,
       record on shop drawings and use to ensure accurate fabrication.
   -   Designated items:___________
       to be agreed with main contractor as required.

       EXTERNAL

420    WOOD DOORSETS

   -   Drawing references - ___________________________
       Generally external doors form part of combined window door assemblies.
       Thermal Performance – window and window and door assemblies to comply
       as a whole with part L2 of the Current Building Regulations.

   -   Manufacturer:
       Rationel Vinduer Ltd
       2 Bridgecourt Office Park
       Walkinstown Avenue
       Dublin 12
       - Tel: 01 4092900
       - Fax: 01 4501002
       - Web: http://www.rationel.ie
       - Web: http://www.nbsplus.co.uk/process.asp
   -   Product reference: DOMUS Entrance Door, DOMUS Terrace Door,
       DOMUS stable door. (Please refer to window/door schedules and drawing
       for combination of units).
   -   Note- Windows and doors can be supplied to BS7950/PAS 24 (Secured by
       Design) if requested, specification for enhanced security performance.

   -   Materials:
   -   Entrance door/ Terrace door/Stable door:
   -   Frame and door Leaf:
   -   Species: Softwood, frames and sashes to be a minimum of two laminations
       with a minimum of 60% heartwood overall and 100% heartwood to
       external face. Moisture content of 12% +/- 3 %.
   -   Finish: Gori-system 890 (water based) – Colour T.B.C

       Entrance door/Stable door:
  -   Panel details: 26mm insulated veneer or painted waterproof HDF panel –
      U-value 1.4 w/m2k (DIN 52619/EN673)
  -   Finish: Gori-system 890 (water based) – Colour T.B.C

  -   Glazing details: 26mm double glazed units (6mm energy laminated glass to
      the inside, 16mm air gap, 4mm toughened glass to the outside(w. Argon)).
      Note - Although generally through out, check window schedules and
      drawings for conformation.

  -   Glazing bar: N/A
  -   Quantity of glazing bars/transoms: See drawings/schedules

  -   Note – Stable door only opens outwards. Height of lower leaf 1000mm
      (Non variable)

  -   Ironmongery / Accessories: Manufacturer's standard - Contact Rationel
      Vinduer Ltd for details.
  -   Entrance doors - 3 grey powder coated hinges, vertically and horizontally
      adjustable. 3point lockable espagnolette prepared for EURO-cylinder.
      Adjustable receivers. Doors with widths above 948 are delivered with sash
      lifter. Clear opening (at 90 degrees) width of frame minus 170mm.

  -   Terrace doors - 3 grey powder coated hinges, vertically and horizontally
      adjustable. 3point lockable espagnolette. Single handle lockable on the
      inside by Euro oval cylinder with rose. Adjustable receivers. Doors with
      widths above 948 are delivered with sash lifter. Clear opening (at 90
      degrees) width of frame minus 170mm. Handle controlled friction break
      (outward opening), No friction break on inward opening doors. A41.00-
      Trickle vent fitted in top rail with external aluminium hood canopy.

  -   Stable doors – 4 grey powder coated hinges, vertically and horizontally
      adjustable – door with 2 point locking espognolette in bottom leaf. Top
      leaf espagnolette prepared for EURO-cylinder. Single handle lockable on
      the inside, no external lock.

  -   Trickle vent fitted in top rail with external aluminium hood canopy –
      (Inward opening only).
  -   Push vent, fitted in hinge side jamb – (Outward opening only)
  -   150mm anodised aluminium kickplates fitted internally and/or externally.
  -   Weather drip – fitted externally at the bottom of the door leaf.
  -   Threshold – Cold bridge insulated aluminium threshold with external
      aluminium cover.
  -   Handles - Can be supplied loose for site fitting.
  -   Back plates - Can be supplied loose for site fitting.
  -   Cylinders - Can be supplied loose for site fitting.




520   SLIDING WOOD DOORSETS
  -   Drawing references - ___________________________
      Generally external doors form part of combined window door assemblies.
      Thermal Performance –window and window and door assemblies to comply as
      a whole with part L2 of the Current Building Regulations.

  -   Manufacturer:
      Rationel Vinduer Ltd
      2 Brigdecourt Office Park
      Walkinstown Avenue
      - Tel: 01 4092900
      - Fax: 01 4501002
      - Web: http://www.rationel.ie
      - Web: http://www.nbsplus.co.uk/process.asp
  -   Product reference: A 48.00 DOMUS Sliding Patio Door
  -   Performance:
  -   Arrangement: G-U936 lift and slide patio door, sliding externally, open
      width half frame minus 219mm.

  -   Frame and door leaf: Softwood, frames and sashes to be a minimum of two
      laminations with a minimum of 60% heartwood overall and 100%
      heartwood to external face. Moisture content of 12% +/- 3 %.

  -   Finish: Gori-system 890 (water based) – Colour T.B.C

  -   Glazing details: Fixed leaf- 24mm double glazed units (6mm energy
      laminated glass to the inside, 14mm air gap, 4mm toughened glass to the
      outside(w. Argon)).
  -   Sliding leaf- 32mm double glazed units (6mm energy laminated glass to
      the inside, 22mm air gap, 4mm toughened glass to the outside(w. Argon)).
      Note - Although generally through out, check window schedules and
      drawings for conformation.

  -   Glazing bar: N/A
  -   Quantity of glazing bars: See drawings/schedules

  -   Ironmongery / Accessories: Manufacturer's standard - Contact Rationel
      Vinduer Ltd for details. Rationel Push vent fitted in the head over fixed
      leaf. External finger pull.
  -   G-U Dirigent locking single handle with internal cylinder - Alternate -
      handle.
  -   G-U Dirigent locking double handle with internal cylinder - Alternate
      handle.
  -   G-U Dirigent locking double handle with double cylinder - Alternate
      handle.

      EXECUTION

710   PROTECTION OF COMPONENTS
   -   General: Do not deliver to site components that cannot be installed
       immediately or placed in clean, dry floored and covered storage.
   -   Stored components: Stack vertical or near vertical on level bearers, separated
       with spacers to prevent damage by and to projecting ironmongery, beads etc.

730    PRIMING /SEALING
   -   Frames and sashes must be treated with a base coat fungicide, usually
       applied by dripping, flowcoat or similar in accordance with DS/EN 927-1,
       along with two further coats of factory applied microporous paint or stain
       finish. Dry paint finish to be between 60-100 microns to a 30% silk gloss
       level.
   -   Timber surfaces inaccessible after installation: Prime or seal as specified
       before fixing components.

760    BUILDING IN
   -   General: Not permitted unless indicated on drawings.
   -   Brace and protect components to prevent distortion and damage during
       construction of adjacent structure.

770    DAMP PROOF COURCE ASSOCIATED WITH BUILT IN WOOD
       FRAMES
   -   Method of fixing – To backs of frames using galvanised clout nails.

780    DAMP PROOF COURCE IN PREPARED OPENINGS
   -   Location: Ensure correct positioning in relation to window frames. Do not
       displace during fixing operation.

790    FIXING OF WOOD FRAMES
   -   Fasteners: manufactures galvanized mild steel cramps or as otherwise
       recommended by the manufacturer.
   -   Spacing: When not predrilled or specified otherwise, position fasteners not
       more than 150mm from ends of jamb, adjacent, to each hanging point of
       opening lights, and maximum 600mm centres.

800    FIXING OF LOOSE TRESHHOLDS
   -   Spacing of fixings: Maximum 150mm from each end and at 600mm maximum
       centres.

820    SEALANT JOINTS
       Sealant:
   -   Manufacturer:____________
   -   Product reference: _____________
   -   Colour: _________________
   -   Application: As Section Z22 to prepared joints. Finished triangular fillets to a
       flat or slightly convex profile.


830    FIXING IRONMONGERY GENERALLY
   -   Fasteners: Supplied by ironmongery manufacturer.
   -   Finish/Corrosion resistance: To match ironmongery.
-   Holes for components: No larger than required for satisfactory fit / operation.
-   Moving parts: Adjusted, lubricated and functioning correctly at completion.

								