Docstoc

Centurion Stove with old matrix.qxd

Document Sample
Centurion Stove with old matrix.qxd Powered By Docstoc
					    Centurion
       CAST IRON FLUELESS GAS STOVE



    INSTALLATION, SERVICING
     AND USER INSTRUCTIONS


      All instructions must be handed to the user for safekeeping

                          Revision A - 07/01
                   Country(s) of destination - GB,IE




Focal Point Fires plc, Avon Trading Park, Christchurch, Dorset BH23 2BT
             Tel: 01202 499330      Fax: 01202 499326
                      www.focalpointfires.co.uk
                  e-mail: sales@focalpointfires.co.uk
   T    T       T   T
INSTALLATION INSTRUCTIONS
Preliminary Notes Before Installation
This appliance is a High Efficiency, Flueless, Live Fuel Effect stove. It provides radiant and
convected warmth both efficiently and safely utilising the latest type catalytic convertor
burner technology.

The stove incorporates a thermostatically controlled gas valve, which can be adjusted by the
control knob on the front of the gas valve, located on the lower right hand side of the stove.
The stove is designed to reduce its heat output as the temperature in the room in which it is
installed rises. The main burner will automatically switch from low to off as the room tem-
perature continues to rise. As the room temperature cools the main burner will switch from
off to low and then adjust its input as required.

This stove incorporates a combustion monitoring system (ODS). It must not be adjusted or
put out of operation. If replaced then manufacturers original parts must be used.

The stove is designed to fit various types of situations as listed in the Installation Requirements.

This appliance must be installed in accordance with the rules in force and only used in a suf-
ficiently ventilated space. A minimum of 100cm2 purpose provided ventilation is required
for this appliance. An openable window or louvre is also required. This appliance is factory
set for operation on the gas type, and at the pressure stated on the appliance data plate.

The room size should be a minimum of 40m3 (1412ft3) to allow adequate circulation of air
and ensure the correct operation of the stove. This volume may include adjacent spaces but
these spaces must not be separated by a door. In order to convert from cubic feet (ft3) to
cubic metres (m3) divide the room volume (in ft3) by 35.3.

The appliance must not be installed in a bedroom, bathroom or any sleeping area. The
appliance does not require a flue system of any type as the catalytic converter cleans the
flue products to provide a complete combustion system, which is intrinsically safe.

The appliance must be installed by a competent person in accordance with Gas Safety
(Installation and Use) Regulations 1998 or rules in force. It is strongly recommended that a
CORGI registered engineer is used for this purpose, as they are the only persons approved
by the HSE under the above regulations.

On initial lightup of a new appliance, the ‘newness’ will burn off within the first few minutes
of operation. During this period some smoke may be emitted from outlet grille, this should
be no cause for concern. Accordingly, the room should be well ventilated with all windows
and doors open during this period.

Read all these instructions before commencing installation.
         c
       Section                    s
                           Contents               g
                                                Page No.          Section
                                                                    c                Contents s              g
                                                                                                           Page No.
        1.0      Important Notes                    1               9.1     Operating the Appliance            6
        2.0      Appliance Data                     2               9.2     Spark Failure                      7
        3.0      Installation Requirements          2               9.3     Setting Pressure                   7
          3.1    Room Sizing                        2              10.0     Briefing the Customer              7
        4.0      Site Requirements                  2              11.0     Servicing                          7
          4.1    Ventilation                        4               11.1    Cleaning the Coals                 8
        5.0      Unpacking the Appliance            4               11.2    Servicing the Burner Tray          8
          5.1    Component Checklist                4               11.3    Pilot Assembly                     8
        6.0      Gas Supply                         4               11.4    Catalyst                           9
        7.0      Securing the Stove                 4               11.5    Testing for Firebox Leakage        9
        8.0      Fuel Bed Layout                    5              12.0     Troubleshooting Guide             10
        9.0      Testing and Commissioning          6


1.0   IMPORTANT NOTES
      This appliance is an Inset Live Fuel Gas Stove providing radiant and convected warmth. It is designed to oper-
      ate on Natural Gas following factory set adjustments. See Data Plate on appliance for gas type and pressure.

      It is the LAW that all gas appliances and fittings are installed by a competent person (such as a CORGI regis-
      tered fitter) and in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British
      Standards for Installation, Codes of Practice and the Manufacturers' Instructions. The installation shall also be
      carried out in accordance with the following regulations:

      The Building Regulations issued by the Department of the Environment, the Building Standards (Scotland)
      (Consolidation) Regulations issued by the Scottish Development Department.

                    s          s s                           s                       s    s c      s
      Relevant British standards insofar as the relevant areas are not covered by these instructions.

                       c                    c                                         s         g s
      Note: For Republic of Ireland, reference should be made to the relevant standards governing installation. (IS
      813: 1996))

      Failure to comply with these regulations could lead to prosecution and will deem the war-
      ranty invalid.

      This appliance must be installed in accordance with the rules in force and used only in a
      sufficiently ventilated space.

      Consult ALL instructions before installation and use of this appliance.

      This appliance is free from any asbestos material. Refractories and coal bed are constructed
      from ceramic fibre.




                                                           1
2.0   APPLIANCE DATA
      Gas Group                                                      G20 Natural Gas CAT I2H
      Inlet Pressure                                                 20 mbar
      Max Energy Input                                               Gross 3.5 kW
                                                                     Net      3.15 kW
      Max Gas Rate                                                   0.33 m3/h
      Min Energy Input                                               Gross 2.1 kW
                                                                     Net      1.89 kW
      Pilot Energy Input                                             Gross 166 W
                                                                     Net      150 W
      Burner Pressure High                                           11.75 (+/-0.5) mbar. Hot
                                                                     11 (+/-0.5) mbar. Cold
                      Low                                            4.8 mbar. Hot
      Main Injector Burner                                           Stereo. Size 60 / Bray CAT 82/280
      Gas Inlet Connection                                           8 mm compression
      Ignition                                                       Piezo spark
      Spark Gap                                                      4.0 mm (± 1.0mm)
      Weight                                                         45 Kg
      Please see Data Badge affixed to appliance for current data.
      This appliance is for use only with the gas type, and at the pressure stated on the appli-
      ance Data Badge.

3.0   INSTALLATION REQUIREMENTS
      This appliance may be installed on a non-combustible hearth having a minimum width of 680mm and a depth
      of 300mm. The hearth must have a minimum thickness of 12mm. If the appliance is to be sited near a disused
      natural draught flue it is recommended that the old flue should be partially sealed off to prevent draughts,
      however some ventilation will be required to prevent condensation.

      It is possible to install the appliance onto certain types of combustible flooring - see section entitled
      ‘Clearances to combustible materials’.

      In the event that the stove is sited in a disused or unserviceable fireplace served by a natural draught flue, any
      existing under grate draught device should be sealed off to prevent loss of heat or creation of draughts. The
      passageway into the flue should be partially sealed to prevent excessive draughts, however some ventilation
      will be required in the old flue to prevent condensation and dampness. Advice should be sought from your
      local building control officer.

3.1   ROOM SIZING
      The room size should be a minimum of 40m3 (e.g. 14’ x 14’ x 7’6) to allow adequate circulation of air and
      ensure the correct operation of the stove. This volume may include adjacent spaces but these spaces must not
      be separated by a door. To calculate a room size in cubic metres (m3) divide the room volume in cubic feet
      (ft3) by 35.3.

4.0   SITE REQUIREMENTS
      This Stove may be installed in any room in a home, however there are exceptions, and the stove may not be
      used in bedrooms, bathrooms or shower rooms.

      Installations in living rooms and conservatories are popular, however other rooms such as kitchens, dining
      rooms and hallways are permitted, providing a suitable natural gas supply is available, and room sizing and
      ventilation requirements are strictly adhered to (see section 4.1).




                                                           2
4.0   SITE REQUIREMENTS (continued)
      The stove is designed to be versatile, and as such will operate correctly when exposed to normal gentle
      draughts experienced within the home. It is not recommended, however that the appliance be installed in
      areas where it is likely to be exposed to persistent strong draughts, that may be generated by outside doors or
      windows, air vents or other. It is recommended that the stove should not be installed within 500mm of any air
      vent.

             c s        c    s     s
      Clearances to non-combustibles

      Non combustible surfaces are defined as brick, metal, marble, concrete etc. and also a number of man-made
      materials impervious to flame. If in doubt refer to the material manufacturer for further information before pro-
      ceeding with installation.

      Clearances to the sides of the stove is 50mm (2in), however clear and easy access to the controls located on
      the lower right hand side of the stove must be allowed for, and we would therefore recommend that 100mm
      (4”) be allowed. Clearance to the front of the stove is 500mm (2ft). Care must be taken that no brickwork or
      other incombustible material protrudes into the area immediately around the base of the stove or area under-
      neath the stove in a way that is likely to affect natural airflow into or around the appliance.

      The back of the stove may be installed directly against a non-combustible wall, providing it is relatively flat and
      does not interfere with the various vent holes in the back panel of the stove.

      It is recommended that the appliance be installed on a non-combustible hearth having a minimum width of
      680mm and a depth of 300mm. The hearth must have a minimum thickness of 12mm. In certain situations
      however, this is not necessary - refer to 'Clearances to combustible materials'.

             c s         s              s
      Clearances to combustible materials

      Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame.
      Generally, any material, which is likely to discolour, melt or misshape when exposed to moderate heat, should
      be considered as a combustible material or surface. Any fire surround to be used in conjunction with this
      stove should be rated at a minimum of 100oC.

      Clearance to the sides of the stove are 100mm(4in) but curtains, drapes and other fabrics are not permitted
      within a distance of 500mm (20”) of the stove sides and back. No such materials are permitted directly above
      the stove regardless of distance. Clearance to the front of the stove is 1000mm (39”). Clearance to the rear of
      the stove is 100mm (4”).

      Installation on a solid non-combustible hearth is usually required, however the appliance may generally be
      installed onto solid combustible surfaces such as hard laminate flooring and wooden floors, as very little heat
      is generated downward by the stove when operating. Such surfaces should be rigid, flat and not likely to
      encourage dust or lint to gather.

      It is not permitted to install the appliance onto carpet, rugs or fabric materials of any kind.

      Installations into 'inglenook' type fireplaces are acceptable, providing adequate consideration is given to any
      wooden cross-members and such like.

      A combustible shelf may be fixed to the wall above the stove, providing that it complies with the dimensions
      given below.
      Maximum depth of shelf                            c
                                          Minimum distance from hearth to underside of shelf
               150mm (6in)                                               1015mm (40in)
               200mm (8in)                                               1115mm (44in)

      The shelf depth may be greater but the height must also be increased accordingly. An increase in height of 25
      mm is required for every 12.5 mm of additional shelf depth. For shelves that are too low, protective devices
      can be used such as metal heat deflectors, but it must be assured that the shelf does not reach an unaccept-
      able temperature before relying on such a solution.

      As with all heating appliances, any decorations, soft furnishings, and all coverings (i.e. flock, blown vinyl and
      embossed paper) positioned too close to the appliance may discolour or scorch.
                                                          3
4.1   VENTILATION
      A minimum of 100 cm2 purpose provided ventilation is required for this appliance. An openable window or
      equivalent is also required. The requirements of other flued appliance operating in the same room or space
      must be taken into consideration when assessing ventilation.

      Any ventilation fitted must comply with BS 5871 part 1 and BS 5440 part 2. Ventilation fitted under, or within
      immediate vicinity of the appliance must not be used as it may adversely effect performance of the ODS sys-
      tem. The appliance MUST NOT be installed in a bedroom, bathroom or any sleeping area.

      For Republic of Ireland, see relevant rules in force.

5.0   UNPACKING THE APPLIANCE
      Remove the banding and outer packaging, lift the stove from its pallet. - CAUTION - this stove is heavy. It is
      strongly recommended that the stove be lifted by two people. Read ALL these instructions before continuing
      to unpack or install this appliance.

      Lift off the lid of the stove to reveal the top of the convector box, and lift away the front panel of the stove for
      easy access to the glass door assembly. The door may be detached by removal of the four large retaining
      screws. Remove the ceramic coals and other ceramic firebed components. Remove the cardboard packing
      pieces and any other bags or boxes containing fittings or other parts. Check that the components supplied
      correlate with the component checklist. Please dispose of all the packaging materials at your local recycling
      centre.

5.1   COMPONENT CHECKLIST
        A
      QUANTITY          DESCRIPTION
         1              Cast iron stove

      Contained within the stove :
          1           Set of manufacturers instructions and warranty card
          1           Fitting template
          1           Removable brass door handle
          1           Moulded ceramic fibre combustion matrix
         14           Individual ceramic coals (5 moulded and 9 broken)
          2           Ceramic fibre side cheeks
          1           Ceramic brick panel
          2           Fixing brackets, M8 nuts & washers
          1           Screw and rawl plug pack

6.0   GAS SUPPLY ROUTES
      The gas inlet connection to the stove is located centrally ,underneath the stoves casing. The gas supply may
      connect to the stove over the hearth or by concealed connection below the stove. Concealed pipes should
      not be routed through walls without being protected by sleeving or conduit. No more than 1.5m of 8mm dia
      pipe must be used to avoid unnecessary pressure drops.

      If a concealed gas connection is to be made, the supply pipe should always be sleeved through walls and
      floors using the shortest possible route.

7.0   SECURING THE STOVE
      Using the fitting template provided, mark the four fixing positions on the hearth. Drill four holes using a 7mm
      bit and fit the fibre rawl plugs provided. Secure the fixing brackets using four fixing screws provided. Position
      the stove onto the fixing brackets so as the holes in the back legs of the stove engage the studs. Using two M8
      nuts and washers, tighten the stove onto the studs. Level the front legs of the stove as required using the
      adjustment bolts. Connect the gas supply to the control valve and tighten the gas connection. Pressurise the
      gas supply and test properly for soundness in accordance with current Approved Codes of Practice.




                                                              4
8.0
      FUEL BED LAYOUT



      Place the brick panel against the rear of the firebox.




                                                                 Place the ceramic combustion matrix onto the burn-
                                                                 er and the ceramic side cheeks onto the matrix.
                                                                 Ensure that the hole for pilot flame viewing is clear
                                                                 and easily visible.




      Place the front row of 5 moulded coals onto the
      matrix, equally spaced across the width of the fire.
      They may be at any rotational orientation desired.
      Ensure their rear edges do not overhang the flame
      ports. Corners or rough edges MUST NOT be allowed
      to enter the flame ports.




                                                                 Place the centre row of four broken coals, making
                                                                 sure that they do not fall down into the flame port
                                                                 but bridge across the spaces as shown. Rotational
                                                                 orientation maybe as desired.




      Place the top row of five broken coals onto the flats in
      the matrix. Ensure the coals are not put into holes in
      the matrix. Bridge the gaps between the support pil-
      lars and rear of the matrix and the centre row of coals.
      Rotational orientation may be as desired.




                                                           5
8.0
      FUEL BED LAYOUT (continued)
                    s     s                     g          s                s
      Note: The coals must not be crammed together or inserted into the holes in the matrix. A well laid out, gener-
        s      c                               s s s
      ously spaced coal layout will give the best results.

      The edges or corners of the front row of coals MUST NOT be allowed to enter the flame slots in the matrix. If
      in doubt, pull them forward as far as possible.

      Refit the glass door and secure in position using the four large retaining screws. Refit the front casting, and
      replace the lid of the stove.

             A                                 c                 s             c        g       c
      SPECIAL NOTE: Evaluate the flame picture with the glass door in place, paying particular attention to any
            s                                  s           s                s            s           s
      flames that play onto the firebox sides or forwards toward the glass door. If this is the case, turn the control
                            s                                                    s                 s          s
      knob to the OFF position and allow the stove to cool. Remove the glass door, and adjust the coals according-       g
             s          c        s                   s                                                 s               s
      ly. This will reduce the possibility of heat discolouration. Be careful not to handle the coals with bare hands as
               c       s                     s s                                     s                          c       g
      they quickly absorb heat. It is always best to spend a little extra time at this point to get the flame picture right
                            s           s                                   c       c g            c
      than to have queries from a customer at a later date. The main factor affecting flame picture and balance is c
      coal layout.
9.0
      TESTING AND COMMISSIONING
      As previously mentioned, firstly turn on and test the gas supply up to the stove for any leaks, in accordance
      with current Approved Codes of Practice (ACOPs).
9.1
      OPERATING THE APPLIANCE
      The pilot is visible through the specially added hole in the left hand side of the matrix.

      Turn the thermostat knob to position 6.

      Turn control knob slightly left towards the ignition position until reaching the stop, press down and hold for 5
      seconds (only pilot gas is flowing). Continue pressing down the knob while turning further to the left to acti-
      vate the piezo spark, continue to hold the knob down for a further 10 seconds after the pilot has been lit. If
      the pilot does not light repeat the previous steps.

      Upon lighting and after the further 10 seconds, release the knob and turn further to the left to the ON posi-
      tion. The main burner will light and be controlled in accordance
      with the thermostat knob setting. Adjust the thermostat knob to
      the desired setting, the higher the number the higher the room
      temperature will become prior to the stove reducing its heat
      input. The thermostat knob does not permanently turn the stove
      on or off.
      At any of the temperature settings the stove may operate at any
      input between maximum and minimum or if the room tempera-
      ture continues to rise, the main burner may switch off. As the
      room temperature falls the main burner will light again.

      If the pilot is extinguished during use of the stove, you MUST wait
      ten minutes before repeating the ignition procedure. To turn the
      main burner OFF, keeping the pilot flame lit, turn the control knob to the pilot position, only the pilot will
      remain lit. To shut the stove off completely, press the knob down and continue turning to the right from the
      pilot position to the OFF position.

      A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled sufficiently to allow
      the magnetic valve unit to reset it self. The elapse time will vary dependant on the temperature of the stove.
9.2
      SPARK FAILURE
      The gap between the spark electrode and the pilot should be 3 - 5mm to produce a good spark. There should
      be no need to adjust this. If under any circumstances the piezo electric spark fails, the pilot cannot be lit man-
      ually.


                                                            6
 9.3
       SETTING PRESSURE
       Remove the screw from the pressure test point, situated on the main burn-
       er supply pipe and protruding from between the gas valve and the fire
       tray, and attach a U gauge. Light the stove and set the thermostat to the
       maximum setting (6).

       The burner pressure should be in accordance with the figures stated in the
       data section of these instructions. The stove is factory set to achieve these
       pressures and any significant variation could indicate a supply problem. If
       the pressure is too high, the gas supply meter may be set incorrectly. This
       should be checked with the stove running and if necessary reset by the
       gas supplier.

       If the burner pressure is too low, then check the meter governor pressure
       with the appliance running. If this is less than approximately 20mbar it will
       need to be reset by the gas supplier.

       If the setting pressure is too low, but the meter pressure is acceptable, then a problem in the supply pipework
       is to be suspected. This will be dirt and debris, kinked or inadequate size pipes, restriction in a fitting, shut off
       elbow not fully open or solder flashing across a joint.

       Switch the stove off, disconnect the U gauge and refit the test nipple screw. Light the stove and check for gas
       soundness.
10.0
       BRIEFING THE CUSTOMER
       All instructions must be handed to the user for safekeeping. Show the customer how to light and control the
       stove.

       After commissioning the appliance, the customer should be instructed on the safe use of the appliance and
       the need for regular servicing. Frequency of service depends on usage, but MUST be carried out at least once
       annually.

       Advise that cleaning of the stove maybe achieved when the stove is cold using a damp cloth and mild deter-
       gent on most surfaces.

       Advise that the stove will emit a "newness" smell for a time after initial commissioning and that extra ventila-
       tion may be needed during this time.

       Recommend that a guard be used for the protection of the young, pets, the elderly and the infirm
11.0
       SERVICING
       Isolate the stove from the gas supply. Ensure that the stove is fully cold before attempting service. A suggest-
       ed procedure for servicing is detailed below.

                1. Lay out a dust sheet and relevant tools.
                2. Removed the stove top with a sharp lift upward, then remove the stove front by lifting away.
                3. Remove the glass door assembly (4 screws) and clean carefully.
                4. Carefully remove the ceramic components.
                5. Inspect the catalyst and clean if necessary with a soft brush.
                6. Disconnect the gas supply and remove the two securing screws in the tray legs.
                7. Lift away burner tray assembly.
                8. Strip off the burner pipes and clean thoroughly.
                9. Clean the injector, pilot assembly and the burner tube. Do not attempt to remove the pilot injector
                   as this can cause damage.
                10. Re-assemble and re-fit the burner tray.
                11. Turn on the gas supply and leak test. Check pilot and burner for good ignition.
                12. Refit the ceramics, paying attention to the final layout as per installation section.
                13. Refit the glass door assembly, ensuring a good seal.

                                                             7
11.0
       SERVICING (continued)
                14. Refit the cast front and then replace the lid, push firmly downward.
                15. Check the purpose provided ventilation is un-obstructed.
                16. Light the stove and test setting pressures.
                17. Check safe operation of the appliance.

11.1   For specific servicing instructions, see relevant sections.

       CLEANING THE COALS
       Remove the stove top with a sharp lift upward and then the stove front by lifting away. Remove the glass door
       assembly. Remove the ceramic components. Gently clean in the open air. Be careful not to create dust from
       the coals. Where necessary replace damaged components with genuine spares. Seal scrap ceramic compo-
       nents in plastic bags and dispose at proper refuse sites as directed. If using a vacuum cleaner, a HEPA filtering
       system is recommended.

       Re-fit the coals by referring to the relevant section of these instructions. Refit the glass door assembly ensuring
       a good seal. Refit the stove front and top.
11.2
       SERVICING THE BURNER TRAY AND GAS ASSEMBLY
       Firstly, remove the top of the stove with a sharp pull upward and then remove the front of the stove by lifting
       away. remove the glass panel, coals and ceramics, and disconnect the gas connection underneath the burner.
       Remove the burner tray itself by removing the 2 securing screws through the legs. The gas connections to the
       gas valve can now be released. Remove the pilot and main burner pipes and blow through to dislodge any
       debris. Remove the injector elbow and blow through to make sure it is entirely clear.

       When replacing the injector elbow, ensure that it is aligned accurately with the centre of the mixer tube enter-
       ing the burner and not at an angle. Always make sure that the nut securing the injector elbow is tight. Un-clip
       the pilot lint gauze and clean with a soft brush. Clean the exterior of the pilot assembly with a soft brush and
       blow through the flame ports on the pilot head. Check the aeration holes are free from lint or dirt. The pilot
       assembly can be removed if required by disconnecting the electrode HT lead, gas pipe and unscrewing the
       mounting screws and lifting away.

       The pilot assembly is a non-serviceable item and should not be taken apart. Aeration holes must be absolutely
       clear internally for proper operation. NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE
                 A
       PILOT STAY ALIGHT. If the pilot will not stay lit there is a problem with dirt, the gas supply to it, the flue con-
       nection or termination, or the thermocouple needs replacement. Modifications are dangerous and can have a
       serious unseen effect on safety.

       The gas valve is a non-serviceable item. If this needs replacement, remove the two M5 securing screws and
       remove the complete valve. Replacement must be done using original manufacturers parts.

       Re-assembly in the reverse of removal.
11.3
       PILOT ASSEMBLY
       Remove the burner tray as in relevant section and pilot unit as described.

       Clean the pilot assembly with a soft brush and blow through. Check the aeration holes are free of any dirt or
       lint. Clean thoroughly internally, the connection can be removed from the base of the pilot unit using two
       spanners to make cleaning easier. Do not damage or try to remove the pilot injector.

       The unit is factory set and the only check necessary is to ensure the spark gap is correct. See specifications
       for gas setting.

                                                                                        A
       NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. If the pilot will not
       stay lit there is a problem with dirt, the gas supply, flue termination or connection, or the thermocouple needs
       replacement. Modifications are dangerous and can have a serious unseen effect on safety and therefore
       MUST not be done. Replacement must be done using original manufacturers parts.
                                                              8
11.4

       CATALYST
       It is recommended that the catalyst is inspected for signs of damage and dirt during routine servicing proce-
       dures.

       The expected life of the catalyst is in excess of 11,000 hours (10 years of normal use). After this time the cata-
       lyst should be replaced.

       If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vacuum
       cleaner. If removed for cleaning, ensure the seals are in good condition before replacing the catalyst. New
       seals will usually be required.

       If replacing, firstly, remove the top of the stove with a sharp pull upward. Remove the front panel of the stove
       by lifting away, then remove the glass door. The catalyst is located behind the top front panel (2 screws),
       remove these screws and the panel. Withdraw the catalyst and its seals forwards and discard.
11.5
       Refit a new catalyst and seals in reverse order, ensure the door has a good seal.

       TESTING FOR FIREBOX LEAKAGE
       Appliances that are several years old or have been extensively dismantled should be checked for soundness. It
       is important that all the products of combustion pass through the catalytic converter at the top of the firebox
       before leaving the appliance.

       The firebox is heated by lighting for a few minutes to provide a flow through the firebox and flue. The burner
       is then shut off and a smoke pellet or match introduced at the base of the stove underneath the burner tray.
       Large quantities of smoke will emerge from the top of the appliance, but none should emerge from the joints
       or gasket faces, especially around the door. It is important to note that the appliance can never be expected to
       be 100% smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc with-
       out affecting safety when the stove is actually in operation.




                                                            9
12.0

       TROUBLESHOOTING GUIDE
                  s              s       g
       Stove sparks but pilot does not light     No gas to stove, check isolators are open.
                                                 Pipe work blockage, clean out.
                                                 Air not fully purged, re purge supply or wait longer.
                                                 Spark earthing to metal work, reset gap correctly.
                                                 Blocked pilot, clean out internally.

               g s              s
       Pilot lights but then goes out            Severe restriction in gas supply: clear obstruction.
                                                 Faulty thermocouple, replace pilot unit.
                                                 Blocked pilot, clean out.
                                                 Blocked lint gauze, clean.
                                                 Hold control knob in for longer.
                                                 NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE
                                                 PILOT STAY ALIGHT. If the pilot will not stay lit there is a problem
                                                 with dirt, the gas supply, or the thermocouple needs replacement.
                                                 Modifications are dangerous and can have a serious unseen effect
                                                 on safety.

                    s      s
       Remote handset does not operate the       Replace the batteries in the battery box/receiver underneath the
       temperature control                       stove.

                s
       Stove does not spark at pilot             HT lead detached, refit.
                                                 Spark gap too large or small, reset correctly.
                                                 Faulty piezo unit, replace.
                                                 Debris shorting out electrode, clean.
                                                 Spark shorting to metalwork under tray, realign HT lead.

                s                        s
       Stove runs for a time and then cuts off   Loose or faulty thermocouple, rectify.
                                                 Blocked pilot, clean out.
                                                 Dirt or lint in pilot aeration hole or on the lint gauze, clean
                                                 thoroughly.
                                                 NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE
                                                 PILOT STAY ALIGHT. If the pilot will not stay lit there is a problem
                                                 with dirt, the gas supply, flue termination or connection, or the
                                                 thermocouple needs replacement. Modifications are dangerous
                                                 and can have a serious unseen effect on safety.

                         s                    g
       Pilot flame shrinks when stove is on high Poor gas flow to stove, check pressure with stove on high.
                                                 If pressure is low, remove any restriction in pipework or valve.
                                                 Check all isolators are adequately sized and fully open.
                                                 Check meter pressure is adequate.
                                                 NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE
                                                 PILOT STAY ALIGHT. If the pilot will not stay lit there is a problem
                                                 with dirt, the gas supply, flue termination or connection, or the
                                                 thermocouple needs replacement. Modifications are dangerous
                                                 and can have a serious unseen effect on safety.

                  s         s
       Stove smells when first lit or in use     Newness smell from brand new appliance.
                                                 Leakage occurring. Carry out leakage test and rectify any problems.
                                                 Low temperature sealants or combustible materials used in
                                                 incorrect positions.




                                                         10
      USER INSTRUCTIONS
        c
      Section                                               Content                                      g
                                                                                                       Page No
        1.0                                       Important Notes                                          1
        2.0                                       Clearances to Combustibles                               2
        3.0                                       Ventilation & Room Size                                  2
        4.0                                       Operating Instructions                                   2
        5.0                                       Combustion Spillage Monitoring System                    3
        6.0                                       Cleaning                                                 3
1.0     6.1
        7.0
                                                  Coals & Ceramics
                                                  Servicing
                                                                                                           3
                                                                                                           5
        8.0                                       List of Replacement Parts                                5

      IMPORTANT NOTES
      The installation and Servicing of this stove MUST only be carried out by a competent person (such as a
      CORGI registered fitter) in accordance with the Gas Safety (Installation and Use) Regulations 1998, the rele-
      vant British Standards, Codes of Practice, the Building Regulations and the manufacturer's instructions.

      Failure to comply with the above recommendations could lead to prosecution and will invalidate the appli-
      ance warranty.

      Please ensure you are handed all of the manufacturers documents on completion of the installation. This will
      include these instructions.

      Always keep a note of the installer's name and address, the original purchase receipt and the date of installa-
      tion for future reference. Failure to produce these documents may invalidate the warranty.

      The stove should be serviced regularly to ensure continued safe operation. See the servicing section for fur-
      ther reference.

      Parts of this appliance become naturally hot during use. It is recommended that a suitable fireguard conform-
      ing to BS 6778 or BS 6539 is used, especially where young children, pets, the elderly or infirm are concerned.

      The stove is fitted with a removable handle which can get hot if it is not removed from the door whilst the
      stove is in operation .

      This stove is designed to become very hot during use. The manufacturer of this appliance considers all sur-
      faces as working surfaces with the exception of the control knob and control panel.

      Combustible items, such as flooring and furniture and soft wall coverings (such as blown vinyl or embossed
      paper), low temperature surrounds etc may discolour if fitted too close to the stove. See relevant section for
      further details on clearances to combustibles. No combustible materials or flooring should protrude onto the
      hearth.

      This appliance incorporates a combustion monitoring system (ODS)

      DO NOT burn any foreign material on this stove, the coals must be of the correct type and laid out in accor-
      dance with the relevant section of the these instructions. Failure to do so may create a hazard or lead to soot-
      ing. Under no circumstances shall the appliance be used if the glass front door or panel has been removed,
      damaged or is open.

      Do not place any objects on top of the stove.

      The integral catalyst should be checked by the installer upon servicing to ensure there are no defects or
      obstructions that may prevent the satisfactory flow of combustion products.
      The expected life of the catalyst is in excess of 11,000 hours (10 years of normal use). After this time the cata-
      lyst should be replaced.
                                                            11
2.0   This appliance is only suitable for the gas type for which it is supplied.



      CLEARANCES TO COMBUSTIBLES
      Clearance to the sides of the stove are 100mm (4in) but curtains, drapes and other fabrics are not permitted
      within a distance of 500mm (20in) of the stove sides and back. No such materials are permitted directly
      above the stove regardless of distance. Clearance to the front of the stove is 1000mm (39”). Clearance to the
      rear of the stove is 100mm (4”).


      Maximum depth of shelf                            c
                                          Minimum distance from hearth to underside of shelf
               150mm (6in)                                               1015mm (40in)
               200mm (8in)                                               1115mm (44in)

      It is not permitted to install the appliance onto carpet, rugs or fabric materials of any kind.

      A combustible shelf may be fixed to the wall above the stove, providing that it complies with the dimensions
      given below.

      The shelf depth may be greater but the height must also be increased accordingly. An increase in height of 25
      mm is required for every 12.5 mm of additional shelf depth. For shelves that are too low, protective devices
      can be used such as metal heat deflectors, but it must be assured that the shelf does not reach an unaccept-
      able temperature before relying on such a solution.
3.0
      As with all heating appliances, any decorations, soft furnishings, and all coverings (i.e. flock, blown vinyl and
      embossed paper) positioned too close to the appliance may discolour or scorch.

      VENTILATION AND ROOM SIZE
      Purpose provided ventilation of 100cm2 is required for this appliance. An openable window or equivalent is
      also required.

      Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2. Ventilation fitted under, or within
      immediate vicinity of the appliance must not be used as it may adversely effect performance of the combus-
      tion monitoring system (ODS) system.

      The requirements of other appliances operating in the space or room must be taken into consideration when
      assessing ventilation requirements, this will have been carried out by your CORGI registered installer.

      A supply of fresh air into the room is advisable to maintain temperatures within limits.

      The appliance MUST NOT be installed in a bedroom, bathroom or any sleeping area.

      For Republic of Ireland, see relevant rules in force.
4.0
      The room size should be a minimum of 40m3 to allow adequate
      circulation of air and ensure the correct operation of the stove.

      OPERATING INSTRUCTIONS
      The pilot is visible through the small hole in the left hand side of
      the matrix front edge.

      Turn the thermostat knob to position 6

      Turn control knob slightly left towards the ignition position until
      reaching the stop, press down and hold for 5 seconds (only pilot
      gas is flowing)

      Continue pressing down the knob while turning further to the left to activate the piezo spark, continue to hold
      the knob down for a further 10 seconds after the pilot has been lit. If the pilot does not light repeat the previ-
      ous steps.                                        12
4.0   Upon lighting and after the further 10 seconds, release the knob and turn further to the left to the ON posi-
      tion. The main burner will light and be controlled in accordance with the thermostat knob setting. Adjust the
      thermostat knob to the desired setting, the higher the number the higher the room temperature will become
      prior to the stove reducing its heat input.
      OPERATING INSTRUCTIONS (continued)
      At any of the temperature settings the stove may operate at any input between maximum and minimum or if
      the room temperature continues to rise, the main burner may switch off. As the room temperature falls the
      main burner will light again.

      If the pilot is extinguished during use of the stove, you MUST wait ten minutes before repeating the ignition
      procedure. To turn the main burner OFF, keeping the pilot flame lit, turn the control knob to the pilot position,
      only the pilot will remain lit. To shut the stove off completely, press the knob down and continue turning to
5.0   the right from the pilot position to the OFF position.

      A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled sufficiently to allow
      the magnetic valve unit to reset it self. The elapse time will vary dependant on the temperature of the stove.

      COMBUSTION MONITORING SYSTEM
      This stove is fitted with a combustion monitoring safety device (ODS). If the stove shuts down during use for
      no apparent reason then several reasons may be suspected. If a door or window has been opened creating a
      draught, then pilot disturbance could be the problem and removal of the draught should resolve this. The
      stove can then be re-lit in accordance with the previous section.

      If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance
6.0   OFF, call in your installer to check the appliance and ventilation. Remedial work must be carried out as
      required. DO NOT allow the appliance to be used until the appliance and installation is passed as safe. If the
      pilot continues to be extinguished, you must call your installer to check the operation of the complete appli-
      ance.

      CLEANING
      Before carrying out any of the following operations, ensure that the stove is OFF and completely cold. Debris
      that may form on the fire bed should be periodically removed by a competent person. Large deposits could
      indicate flue problems or incorrect coal placement. This should be repaired by a competent person and the
      stove serviced before further use. To gain access to the fire bed, lift off the lid of the stove, and then lift out
      the front casting. Remove the four retaining screws and detach the glass door assembly. The glass can be
      cleaned with a suitable glass cleaner. Test on a small area first.
6.1
      Always ensure the area below the stove is clear of any debris or dust.

      PAINTED AREAS - These can be cleaned using a dry cloth.

      COALS AND CERAMICS
      Lift off the lid of the stove and lift out the front cast-
      ing. Remove the glass door assembly. Remove the
      ceramic components. Gently clean in the open air.
      Be careful not to create dust from the coals. Where
      necessary replace damaged components with gen-
      uine spares. Seal scrap ceramic components in plas-
      tic bags and dispose at proper refuse sites as direct-
      ed. If using a vacuum cleaner, a HEPA filtering system
      is recommended.

      Replacing the coals and ceramics are as follows




      Place the brick panel against the rear of the firebox.
                                                             13
6.1




                                                                  COAL AND CERAMICS (contin-
                                                                  ued)


      Place the ceramic combustion matrix onto the burner
      and the ceramic side cheeks onto the matrix. Ensure
      that the hole for pilot flame viewing is clear and easily
      visible.




                                                                  Place the front row of 5 moulded coals onto the
                                                                  matrix, equally spaced across the width of the fire.
                                                                  They may be at any rotational orientation desired.
                                                                  Ensure their rear edges do not overhang the flame
                                                                  ports. Corners or rough edges MUST NOT be
                                                                  allowed to enter the flame ports.




      Place the centre row of four broken coals, making sure
      that they do not fall down into the flame port but
      bridge across the spaces as shown. Rotational orienta-
      tion maybe as desired.




      Place the top row of five broken coals onto the flats in the matrix. Ensure the coals are not put into holes in
      the matrix. Bridge the gaps between the support pillars and rear of the matrix and the centre row of coals.
      Rotational orientation may be as desired.




                    s     s                     g          s                s
      Note: The coals must not be crammed together or inserted into the holes in the matrix. A well laid out, gener-
        s      c                               s s s
      ously spaced coal layout will give the best results.

      The edges or corners of the front row of coals MUST NOT be allowed to enter the flame slots in the matrix. If
                                                           in doubt, pull them forward as far as possible.
                                                       14
6.1   Refit the glass door and secure in position using the four large retaining screws. Refit the front casting, and
      replace the lid of the stove.




      COAL AND CERAMICS (continued)
             A                                 c                 s             c        g       c
      SPECIAL NOTE: Evaluate the flame picture with the glass door in place, paying particular attention to any
            s                                  s           s                s            s           s
      flames that play onto the firebox sides or forwards toward the glass door. If this is the case, turn the control
7.0                         s                                                    s                 s          s
      knob to the OFF position and allow the stove to cool. Remove the glass door, and adjust the coals according-       g
             s          c        s                   s                                                 s               s
      ly. This will reduce the possibility of heat discolouration. Be careful not to handle the coals with bare hands as
               c       s                     s s                                     s                          c       g
      they quickly absorb heat. It is always best to spend a little extra time at this point to get the flame picture right
                            s           s                                   c       c g            c
      than to have queries from a customer at a later date. The main factor affecting flame picture and balance is c
      coal layout.


      SERVICING
      The stove should be checked on an annual basis to it is working safely and that there is no excessive build up
8.0   of soot. The frequency of service will depend on usage, but MUST be carried out at least once annually.
      Servicing must be carried out by a competent person, such as a CORGI registered installer.

      Cleaning of the coals may be carried out by following the instructions given in the Installation section. The
      Installation instructions carry full servicing details for the use of the installer.

      LIST OF SPARE PARTS
       A
      PART NO.                             ITEM
      FT003820-0                 Pack of 5 moulded coals
      FT003825-0                 Pack of 9 broken coals
      FT003815-0                 Ceramic combustion matrix
      FB004030/0                 Ceramic side cheeks
      FB004050/0                 Ceramic brick panel
      FB004225/5                 Glass door assembly
      FT003710/5                 Pilot assembly
      Please Enquire             Gas valve
      Please Enquire             Burner tray
      Please Enquire             Catalyst (seal kit must also be supplied)
      Please Enquire             Seal kit for Catalyst




                                                            15

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:18
posted:9/14/2011
language:English