1707005pdf by msds

VIEWS: 4 PAGES: 6

									- - - - - - - - - - - - - - - - MATERIAL SAFETY DATA SHEET - - - - - - - - - - - - - - Stanbio
At the present time there is no Material Safety Data Sheet available for Bilirubin Test Kit. The following Safety Sheets apply to the ingredients of this product: ----------------------------------------------------------INGREDIENT COMPAS CODE ----------------------------------------------------------Bilirubin - Mixi-Tube #1 17070060 Bilirubin - Mixi-Tube #2 17070070 ----------------------------------------------------------For more information contact the manufacturer of Bilirubin Test Kit: STANBIO LABORATORY, INC. 2930 EAST HOUSTON STREET SAN ANTONIO, TX 78202 (210) 222-2108 MSDS NUMBER: G503-25 DATE PREPARED: May 1990 (Revised) ----------------------------------------------------------NOTICE: While Stanbio Laboratory, Inc. believes the information contained herein is valid and accurate, Stanbio makes no Warranty or Representation as to its validity, accuracy or currency. Stanbio shall not be liable or otherwise responsible in any way for use of either this information or the material to which it applies. ----------------------------------------------------------APPROVED BY: Kirk Johnson REPRESENTING: Stanbio Laboratory, Inc. DATE: 09/13/95 COMPAS Code: 17070051

BILIRUBIN TEST KIT

Page 1 of 1

- - - - - - - - - - - - - - - - MATERIAL SAFETY DATA SHEET - - - - - - - - - - - - - - Stanbio
IDENTITY (Trade Name As Used On Label): Bilirubin - MixiTube #1 MSDS NUMBER*: CAS NUMBER*: 7647-01-0 DATE PREPARED: May 1990 (Revised) PREPARED BY*: MANUFACTURER: STANBIO LABORATORY, INC. 2930 E. HOUSTON STREET SAN ANTONIO, TEXAS 78202 PHONE NUMBER (FOR INFORMATION): (210) 222-2108 EMERGENCY PHONE NUMBER: TELEX*: ----------------------------------------------------------SECTION 1 - MATERIAL IDENTIFICATION AND INFORMATION ----------------------------------------------------------COMPONENTS - Chemical Name & %* OSHA ACGIH Common Names (Hazardous PEL TLV Components 1% or greater; Carcinogens 0.1% or greater) ----------------------------------------------------------Hydrochloric acid 1.5 OTHER LIMITS RECOMMENDED: Non-Hazardous Ingredients TOTAL 100 ----------------------------------------------------------SECTION 2 - PHYSICAL / CHEMICAL CHARACTERISTICS ----------------------------------------------------------BOILING POINT: 100 deg. C VAPOR PRESSURE (mm Hg and Temperature): Approx. 18 @ 20 deg. C VAPOR DENSITY (Air = 1): >1 SOLUBILITY IN WATER: Aqueous solution SPECIFIC GRAVITY (H2O = 1): 1 MELTING POINT: EVAPORATION RATE (H2O = 1): 1 WATER REACTIVE: APPEARANCE AND ODOR: Clear, colorless, acidic odor ----------------------------------------------------------SECTION 3 - FIRE AND EXPLOSION HAZARD DATA ----------------------------------------------------------FLASH POINT AND METHOD USED: Not flammable AUTO-IGNITION TEMPERATURE: FLAMMABILITY LIMITS IN AIR % BY VOLUME: LEL: N/A UEL: N/A EXTINGUISHER MEDIA: N/A SPECIAL FIRE FIGHTING PROCEDURES: Use self-contained breathing apparatus, HCl fumes are corrosive. UNUSUAL FIRE AND EXPLOSION HAZARDS: None ----------------------------------------------------------SECTION 4 - REACTIVITY HAZARD DATA ----------------------------------------------------------STABILITY: Stable. CONDITIONS TO AVOID: INCOMPATIBILITY (Materials to Avoid): Strong bases can cause reaction generating heat HAZARDOUS DECOMPOSITION PRODUCTS: Hydrogen gas when in contact with active metals. HAZARDOUS POLYMERIZATION: Will Not Occur. CONDITIONS TO AVOID: ----------------------------------------------------------SECTION 5 - HEALTH HAZARD DATA ----------------------------------------------------------PRIMARY ROUTES OF ENTRY: Inhalation, Skin Absorption, Ingestion. CARCINOGEN LISTED IN: Not Listed. HEALTH HAZARDS: ACUTE: CHRONIC: SIGNS AND SYMPTOMS OF EXPOSURE: Corrosive and irritating to eyes and tissue on contact MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE:

BILIRUBIN - MIXI-TUBE #1
EMERGENCY AND FIRST AID PROCEDURES: Seek medical assistance for further treatment, observation and support if necessary. EYE CONTACT: Flush with plenty of water SKIN CONTACT: Flush with plenty of water INHALATION: Remove to fresh air INGESTION: DO NOT INDUCE VOMITING. Give large amounts of water or milk. ----------------------------------------------------------SECTION 6 - CONTROL AND PROTECTIVE MEASURES ----------------------------------------------------------RESPIRATORY PROTECTION (Specify Type): Not applicable for laboratory size amounts PROTECTIVE GLOVES: None EYE PROTECTION: Safety glasses VENTILATION TO BE USED: Mechanical (general) OTHER PROTECTIVE CLOTHING AND EQUIPMENT: None HYGIENIC WORK PRACTICES: ----------------------------------------------------------SECTION 7 - PRECAUTIONS FOR SAFE HANDLING AND USE/LEAK PROCEDURES ----------------------------------------------------------STEPS TO BE TAKEN IF MATERIAL IS SPILLED OR RELEASED: Cover with soda ash and flush spilled area with copious amounts of water. WASTE DISPOSAL METHODS: Neutralize and flush down drain. PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: None OTHER PRECAUTIONS AND/OR SPECIAL HAZARDS: NFPA RATING*: HEALTH: FLAMMABILITY: REACTIVITY: SPECIAL: HMIS RATING*: HEALTH: FLAMMABILITY: REACTIVITY: PERSONAL PROTECTION: ----------------------------------------------------------* Optional ----------------------------------------------------------NOTICE: While Stanbio Laboratory, Inc. believes the information contained herein is valid and accurate, Stanbio makes no Warranty or Representation as to its validity, accuracy or currency. Stanbio shall not be liable or otherwise responsible in any way for use of either this information or the material to which it applies. ----------------------------------------------------------APPROVED BY: Kirk Johnson REPRESENTING: Stanbio Laboratory, Inc. DATE: 09/13/95 COMPAS Code: 17070061

Page 1 of 1

- - - - - - - - - - - - - - - - MATERIAL SAFETY DATA SHEET - - - - - - - - - - - - - - Stanbio
IDENTITY (Trade Name As Used On Label): Bilirubin - MixiTube #2 MSDS NUMBER*: CAS NUMBER*: 67-56-1 DATE PREPARED: PREPARED BY*: MANUFACTURER: STANBIO LABORATORY, INC. 2930 E. HOUSTON STREET SAN ANTONIO, TEXAS 78202 PHONE NUMBER (FOR INFORMATION): (210) 222-2108 EMERGENCY PHONE NUMBER: TELEX*: ----------------------------------------------------------SECTION 1 - MATERIAL IDENTIFICATION AND INFORMATION ----------------------------------------------------------COMPONENTS - Chemical Name & %* OSHA ACGIH Common Names (Hazardous PEL TLV Components 1% or greater; Carcinogens 0.1% or greater) ----------------------------------------------------------Methanol 100 OTHER LIMITS RECOMMENDED: Non-Hazardous Ingredients TOTAL 100 ----------------------------------------------------------SECTION 2 - PHYSICAL / CHEMICAL CHARACTERISTICS ----------------------------------------------------------BOILING POINT: 65 deg. C VAPOR PRESSURE (mm Hg and Temperature): 100 @ 21 deg. C VAPOR DENSITY (Air = 1): >1 SOLUBILITY IN WATER: Soluble SPECIFIC GRAVITY (H2O = 1): 0.8 MELTING POINT: EVAPORATION RATE (H2O = 1): >1 WATER REACTIVE: APPEARANCE AND ODOR: Clear, colorless, mild alcohol-like odor ----------------------------------------------------------SECTION 3 - FIRE AND EXPLOSION HAZARD DATA ----------------------------------------------------------FLASH POINT AND METHOD USED: 11 deg. C AUTO-IGNITION TEMPERATURE: FLAMMABILITY LIMITS IN AIR % BY VOLUME: 100 LEL: 6 UEL: 36 EXTINGUISHER MEDIA: Alcohol foam, dry chemical or water fog SPECIAL FIRE FIGHTING PROCEDURES: Methanol is a poison, wear self-contained breathing apparatus UNUSUAL FIRE AND EXPLOSION HAZARDS: Vapor heavier than air ----------------------------------------------------------SECTION 4 - REACTIVITY HAZARD DATA ----------------------------------------------------------STABILITY: Stable. CONDITIONS TO AVOID: INCOMPATIBILITY (Materials to Avoid): Strong oxidizers HAZARDOUS DECOMPOSITION PRODUCTS: Oxides of carbon HAZARDOUS POLYMERIZATION: Will Not Occur. CONDITIONS TO AVOID: ----------------------------------------------------------SECTION 5 - HEALTH HAZARD DATA ----------------------------------------------------------PRIMARY ROUTES OF ENTRY: Inhalation, Skin Absorption, Ingestion. CARCINOGEN LISTED IN: Not Listed. HEALTH HAZARDS: ACUTE: Poison if ingested. CHRONIC: SIGNS AND SYMPTOMS OF EXPOSURE: Irritate eyes on contact, toxic if inhaled MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE:

BILIRUBIN - MIXI-TUBE #2
EMERGENCY AND FIRST AID PROCEDURES: Seek medical assistance for further treatment, observation and support if necessary. EYE CONTACT: Flush with plenty of water SKIN CONTACT: Flush with plenty of water INHALATION: Remove to fresh air, restore or support breathing if necessary. Get medical help. INGESTION: Drink water - induce vomiting. Get medical attention. ----------------------------------------------------------SECTION 6 - CONTROL AND PROTECTIVE MEASURES ----------------------------------------------------------RESPIRATORY PROTECTION (Specify Type): Not normally required PROTECTIVE GLOVES: Not required EYE PROTECTION: Safety glasses VENTILATION TO BE USED: Mechanical (general) OTHER PROTECTIVE CLOTHING AND EQUIPMENT: None HYGIENIC WORK PRACTICES: ----------------------------------------------------------SECTION 7 - PRECAUTIONS FOR SAFE HANDLING AND USE/LEAK PROCEDURES ----------------------------------------------------------STEPS TO BE TAKEN IF MATERIAL IS SPILLED OR RELEASED: Absorb on inert material and place in fume hood WASTE DISPOSAL METHODS: Disposal of hazardous material should be managed in accordance with federal, state and local regulations. PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: Store at Room temperature away from all sources of ignition OTHER PRECAUTIONS AND/OR SPECIAL HAZARDS: None NFPA RATING*: HEALTH: FLAMMABILITY: REACTIVITY: SPECIAL: HMIS RATING*: HEALTH: FLAMMABILITY: REACTIVITY: PERSONAL PROTECTION: ----------------------------------------------------------* Optional ----------------------------------------------------------NOTICE: While Stanbio Laboratory, Inc. believes the information contained herein is valid and accurate, Stanbio makes no Warranty or Representation as to its validity, accuracy or currency. Stanbio shall not be liable or otherwise responsible in any way for use of either this information or the material to which it applies. ----------------------------------------------------------APPROVED BY: Kirk Johnson REPRESENTING: Stanbio Laboratory, Inc. DATE: 09/13/95 COMPAS Code: 17070071

Page 1 of 1


								
To top