ff-q-equip by ashrafp

VIEWS: 4 PAGES: 7

									                     Foundry & Forge Division, Bangalore


       1.   METROLOGY EQUIPMENT


                                                                Remarks
         TEST                                                   (YEAR OF
SL.                   NAME OF                      RANGE /
      FACILITIES /                   MAKE                       PURCHASE /
NO.                    EQUIP.                     ACCURACY
      PARAMETERS                                                INSTALLATION)


                                                  702 – 710 –
                       MICRO         BUEHLER
       HARDNESS                                      200G
1.                    HARDNESS      MICROMET                       FEB. 1998
      MEASUREMENT                                 693 – 701 –
                       TESTER      2100 SERIES
                                                     500G



       NOTE :    CONVENTIONAL DIMENSIONAL MEASURING INSTRUMENTS SUCH
                 AS CALIPERS, MICROMETERS, HEIGHT GAUGES ETC., NEED NOT
                 BE INCLUDED IN THE LIST.
       2.    MECHANICAL TESTING EQUIPMENTS

                                                                           Remarks
                                                                           (Year of
SL.   TEST FACILITIES /                                      RANGE /
                           NAME OF EQUIP.        MAKE                      Purchase /
NO.   PARAMETERS                                            ACCURACY
                                                                           Installation)

      TO ASSESS
      MECHANICAL
                           UNIVERSAL                        AS PER ASTM
 1    PROPERTIES OF TEST                         AVERY                          1958
                           TESTING MACHINE                  STANDARDS
      BARS COMPRESSION
      TEST

      TO ASSESS CREEP      CREEP     TESTING                AS PER ASTM
 2                                               SATEC                          1978
      VALUE                MACHINE                          STANDARDS

                           IMPACT    TESTING                AS PER ASTM
 3    IMPACT VALUE                                FIE                           1961
                           MACHINE                          STANDARDS
                           STRESS   RUPTURE                 AS PER ASTM
 4    STRESS RUPTURE                             SATEC                          1978
                           TESTING MACHINE                  STANDARDS
      TENSILE, FRACTURE
                           UNIVERSAL                        AS PER ASTM
5.    TOUGHNESS. FCGR &                        DARTEC, UK                       1994
                           TESTING MACHINE                  STANDARDS
      LCF
                           ROTATING   BEAM
      FATIGUE LIFE OF                                       AS PER ASTM
 6                         FATIGUE TESTING        HAL                           1990
      METALLIC MATERIALS                                    STANDARDS
                           MACHINE
      FATIGUE TEST AT      HOT     ROTATING
                                                            AS PER ASTM
 7    ELEVATED             FATIGUE TESTING        HAL                           1992
                                                            STANDARDS
      TEMPERATURE          MACHINE
      TO ASSESS CORROSION STRESS                            AS PER ASTM
 8                                                HAL                           1996
      CRACKING            CORROSION                         STANDARDS
      COMPRESSION
                           UNIVERSAL                        AS PER ASTM
 9    BENDING AND PROOF                          OLSEN                          1961
                           TESTING MACHINE                  STANDARDS
      TEST
      COMPRESSION &        SPRING  TESTING                  AS PER ASTM
10                                              COMECO                          1969
      TENSILE OF SPRINGS   MACHINE                          STANDARDS
      TENSION OF FLAT
      SPECIMEN             UNIVERSAL                        AS PER ASTM
11                                              DENISON                         1965
      COMPRESSION TEST     TESTING MACHINE                  STANDARDS
      COMPRESSION
      TO FIND THE TORQUE
                           TORSION   TESTING                AS PER ASTM
12    OF METALLIC                                AVERY                          1965
                           MACHINE                          STANDARDS
      MATERIALS

NOTE : CONVENTIONAL DIMENSIONAL MEASURING INSTRUMENTS SUCH AS             CALIPERS,
MICROMETERS, HEIGHT GAUGES ETC., NEED NOT BE INCLUDED IN THE LIST.
        3.    N.D.T EQUIPMENTS

                                                                                         Remarks
SL.   TEST FACILITIES /                                              RANGE /             (Year of
                        NAME OF EQUIP.           MAKE
NO.   PARAMETERS                                                     ACCURACY            Purchase /
                                                                                         Installation)
                                                                     KV – RANGE 75 –
      RADIOGRAPHIC                               ANDREX
                           250 KV X-RAY                              250 EFFECTIVE
1     INSPECTION OF                              DENMARK                                 1975
                           EQUIPMENT                                 FOCAL SPOT
      MATERIALS                                  MODEL 2501
                                                                     2.9 X 2.9 MM
                                                                     KV – RANGE 15 –
      RADIOGRAPHIC                               ANDREX              160      COARSE
                           150 KV X-RAY                                                  SEPTEMBER
2     INSPECTION OF                              DENMARK      CP -   FOCUS 1.5 MM
                           EQUIPMENT                                                     1986
      MATERIALS                                  160                 FINE FOCUS 0.4
                                                                     MM
      INTERNAL FLAW
                                                 ESM 2
      DETECTION IN         ULTRASONIC FLOW                           SENSITIVITY IN 2    SEPTEMBER
3                                                M/S. EEC
      WROUGHT              DETECTOR                                  dB INCREMENTS       1992
                                                 MUMBAI
      PRODUCTS
      INTERNAL FLAW
                                                 EPOCH 2002          SENSITIVITY IN
      DETECTION IN         ULTRASONIC FLOW
4                                                PARAMETRICS,        0.1 dB              OCTOBER 1986
      WROUGHT              DETECTOR
                                                 USA                 INCREMENTS
      PRODUCTS
      AIRCRAFT
                           EDDY CURRENT          INSTITUTE DR.       DETECTS CRACKS
      MAINTENANCE
5                          DEFECTOMETER          FORSTER W           DOWN TO DEPTH       JULY 1997
      SURFACE FLAWS /
                           2.837                 GERMANY             OF 20 MICRONS
      MATERIAL MIX
      TO CHECK  IN NON EDDY CURRENT             TECHNOFOUR,         10% IACS
                                                                                         NOVEMBER
6     FERROUS METALS IN CONDUCTIVITY             PUNE    TYPE        - 110 % IACS
                                                                                         1991
      % IACS            METER                    – 901               + 1 % IACS
                                                 REICH –
      INTERPRETATION OF FILM VIEWER -            SEIFERT
7                                                                    TRANSMISSION        MAY 1999
      RADIOGRAPHS       SUPER                    GERMANY 9960
                                                                     DENSITY UPTO 4.5
                                                 22 34/01
      FOR ON LINE
                                              MAGNFLUX               0 – 6000 AMPS AC,
      CALIBRATION OF       DIGITAL TEST METER                                            NOVEMBER
8                                             CORPORATION            FWDC & HWDC +
      AMMETERS IN MPI      KIT    TK – 6 DAH                                             1987
                                              USA                    2 % OF READING
      UNITS
                                                                     0 – 4D
      TO MEASURE                                 PULSE ECHO
                           TRANS             4                       MEASURING
9     OPTICAL DENSITY                            SYSTEM                                  JULY 1999
                           DENSITOMETER                              RANGE + 0.02 D
      ON RADIOGRAPHS                             MUMBAI
                                                                     ACCURACY

        NOTE :        CONVENTIONAL DIMENSIONAL MEASURING INSTRUMENTS SUCH
                      AS CALIPERS, MICROMETERS, HEIGHT GAUGES ETC., NEED NOT
                      BE INCLUDED IN THE LIST.
       4.        PAINT AND SEALANT EQUIPMENTS

                                                                            Remarks
                                                                            (Year of
SL. TEST FACILITIES /           NAME OF                      RANGE /
                                                MAKE                        Purchase /
NO PARAMETERS                   EQUIP.                       ACCURACY
                                                                            Installation)


                              Computerised
     Tensile, Elongation &                      R&D
1.                            tensile testing                5T             1999
     compressibility testing.                   Equipment
                              machine

                                Hot Air Oven
2.   For heat ageing tests                      -            + 20 C         1999
                                (2 Nos)

                                Weighing
3    For weighing purpose                       Metler       + 0.01 100g    -
                                balance

                                Micro
     Micro hardness        of
4                               hardness        Karl Frank   1 to 100       1982
     rubbers
                                tester

5    Viscosity tests            Viscometer      Saybolt      -              1986

                                                Brooks       4 – 20,000 C
6    Viscosity                  Viscometer                                  1990
                                                Field        poise

7    For heat ageing tests      Hot Air Oven    -            0 to 1200C     1986



       NOTE :          CONVENTIONAL DIMENSIONAL MEASURING INSTRUMENTS SUCH
                       AS VERNIER CALIPERS, MICROMETERS, HEIGHT GAUGES ETC.,
                       NEED NOT BE INCLUDED IN THE LIST.
     5. OTHER EQUIPMENT (CHEMICAL)
                                                                           Remarks
SL. TEST FACILITIES          NAME OF                        RANGE /        (Year of
                                              MAKE
NO / PARAMETERS              EQUIP.                         ACCURACY       Purchase /
                                                                           Installation)
     Estimation of                            Leco
                             Hydrogen                      0.1 - 250ppm
1.   Hydrogen in                              Corporation,                 2000
                             Determinator                  + 0.05 ppm
     Steel/Titanium Alloy                     USA
     High speed                              Baird
                             Baird                        < 1.0 %
2.   quantitative analysis                   Corporation,                  1986
                             Spectrovac DV-4              of the value
     of metal and alloys.                    USA
     Absorption
                             UV          Vis
     Spectrophotometer                       Systronics,    200–1000nm
3.                           Spectrophotome                                1999
     (analysis of                            Bangalore      + 1nm
                             ter 119
     metals/alloys)
                                                            0 – 14(pH)
     pH   and   millivolt                     Systronics,   + 0.002
4.                        pH Meter - 362                                  1998
     measurement                              Bangalore     0 –1999.9(mv)
                                                            + 0.1 mv
     Conductivity
                                              Systronics,   0 – 14
5.   titrations / pH         Auto Titrator                                 1985
                                              Bangalore     + 0.05
     measurement
                                              Sargent –
     Electro deposition of
6.                         Electro Analyzer   Slomin,       -              1970
     metals
                                              Chicago
     Estimation of carbon                   Leco
                           Leco      carbon
7.   content            in                  Corporation, 0.01 – 4.0 %      1979
                           apparatus
     metals/alloys                          USA

     For weighing of         Analytical       E. Mettler,   Upto 160grms
8.                                                                         1970
     samples for analysis    Balance          Germany       + 0.05mg

     For weighing of         Analytical       E. Mettler,   Upto 200grms
9.                                                                         1970
     samples for analysis    Balance          Germany       + 0.05mg
     NOTE :        CONVENTIONAL DIMENSIONAL MEASURING INSTRUMENTS SUCH
                   AS VERNIER CALIPERS, MICROMETERS, HEIGHT GAUGES ETC.,
                   NEED NOT BE INCLUDED IN THE LIST.
          6. QUALITY CONTROL DEPARTMENT EQUIPMENTS

                                                                                        Remarks
SL.   TEST FACILITIES /        NAME OF                                 RANGE /          (Year of
                                                    MAKE
NO      PARAMETERS             EQUIP.                                  ACCURACY         Purchase /
                                                                                        Installation)
       Inspection of blade     Co-ordinate
                                                    L.K. Limited
1     forgings & proving of    measuring                               2 Microns            Sep-1998
                                                    U.K
             tooling.          machine
                               3D Layout marking
       Layout marking and                           MMT India
2                              and measuring                           50 Microns            Apr-02
      inspection of Castings                        Bangalore
                               machine
                                                    Heinr
         Blades Aerofoil
3                              Profile projector    Schneider          5 Microns            Nov-1990
         measurement
                                                    Germany
         Blades Aerofoil                            OMT.UK
4                              Profile projector                       25 Microns                1972
         measurement                                2 Nos.
                               Aerofoil thickness
        Aerofoil thickness                          Vernon
5                              measuring                               25 Microns                1977
         measurement                                England
                               machine
6                              Hardness             1. Wolpert-2
                               checking machine     Nos.                                    1977-1992
                                                       Germany
                                                    2. Saroj India-2
           Hardness                                 Nos.               Vickers BHN,
          measurement          Portable Hardness    3. FIE India-2     Rockwell             1995-2000
                               Tester               Nos.

                                                    4. Eqotip-2 Nos.
                                                       Switzerland
       Crack detection of      Magnetic particle    ORMS Pavan         0-6000 amps 0-   Apr-77          Dec-
7
         Ferrous items         testing machine       India             2000 amps                 83
                                                    1. Electronic
                                                       engineering
                                                       company
                                                       India
      Internal Soundness of    Ultrasonic testing                      0-10 mm min 0-
8                                                   2. Modsonic                             1990-1997
           all Forgings        machine                                 10 meter (max)
                                                       MSL-32 India
                                                    3. Krant kramer
                                                       MSK-7D
                                                       Germany
                                                    1. 300 K.V
      Internal Soundness of                            Andrex          25 mm Steel 20
9                           X-ray Machine                                                        1973
      all Castings                                  2. 250 K.V         mm Steel
                                                       Andrex
     For friction & wear                                    Kinetic
                               Friction Test   Indigenous
10   properties of break                                    energy3.14         1986
                               Equipment       make
     pad                                                    (Kgfm)
         NOTE :            CONVENTIONAL DIMENSIONAL MEASURING INSTRUMENTS SUCH
                           AS VERNIER CALIPERS, MICROMETERS, HEIGHT GAUGES ETC.,
                           NEED NOT BE INCLUDED IN THE LIST.

								
To top