towerMAX Series
AC Protection
M8T—PREMIER SERIES 8-OUTLET AC SURGE PROTECTOR WITH TELEPHONE PROTECTION
Features
• • • • • • • • AC protection for telecom systems SurgeGate Plus Circuitry Protect or Disconnect Circuitry Eight AC outlets power with four switched outlets Diagnostic indicator lights (four) Eight foot power cord with right angle plug EMI/RFI noise filtration Telephone protection for one voice or DSL line
Designs and specifications are subject to change without notice due to product improvement.
Technical Specifications
PRODUCT SPECIFICATIONS:
Agency Approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL1363, 1449 LED Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Grounding Requirements . . . . . . . . . . . . . . . Uses Electrical AC Ground ........................................................ ........................................................ Ground Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25" Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.75" Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5" Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 lbs Product Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lifetime Connected Equipment Warranty. . . . . . . . . . . . . . . . . . . Up to $50,000
For up-to-date warranty information see our web site: ww.itwlinx.com
SIGNAL LINE SURGE PROTECTION:
TELCO CIRCUIT PROTECTION Signal Perfect Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Fuseless/Auto-Resettable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Clamping Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260V Response Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–5 Nanoseconds Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <50pF Suppression Modes. . . . . . . . . . . . . . . . . . . . . . Metallic & Longitudinal Wires Protected . . . . . . . . . . . . . . . . . . . . . . . . 2-wire, 1-pair (pins 3, 4) Termination Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ-11 COAX CIRCUIT PROTECTION Signal Perfect Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Fuseless/Auto-Resettable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Response Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Termination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Antenna/Cable Lines Protected . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Antenna/Cable Clamping Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Antenna/Cable Attenuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Satellite Lines Protected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Satellite Clamping Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Satellite Attenuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A LAN CIRCUIT PROTECTION Signal Perfect Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Fuseless/Auto-Resettable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Performance Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Clamping Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Response Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Wires Protected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Termination Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
AC SURGE PROTECTION:
SurgeGate Plus Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Protect or Disconnect Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Thermal Fusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Catastrophic Surge Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Over/Undervoltage Voltage Protection. . . . . . . . . . . . . . . . . . . . . . . . Yes Overvoltage Voltage Shutoff. . . . . . . . . . . . . . . . . . . . . . . . . . 147V ±8V Undervoltage Voltage Shutoff. . . . . . . . . . . . . . . . . . . . . . . . . . 87V ±8V Single Pulse Energy Dissipation . . . . . . . . . . . . . . . . . . . . . . 1650 Joules Peak Impulse Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52,000 A EMI/RFI Noise Filtration. . . . . . . . . . . . . . . . . . . . . . . . . 50db (99.7%) Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120V (50/60Hz) Initial Clamping Level. . . . . . . . . . . . . . . . . . . . . . 200V Peak, 141 Rms UL 1449 Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330V Protection Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L-N, L-G, N-G Maximum Current Rating . . . . . . . . . . . . . . . . . . . . . . . . 15A (1800W) Response Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–5 Nanoseconds Plug Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Right Angle Number of Outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Switched Outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Cord Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8'
Applications:
• Telephone Systems • Workstations • Printers • Fax Machines • Copiers • TVs / VCRs • Cameras • Access Controls • Alarms
More information is available in the Technical Reference section of this catalog, turn to page 92.
Ordering Information
ITW Linx Part Number M8T Description 8-outlet AC surge protector, with SurgeGate Plus circuitry. Plus protection for one voice or DSL line.
Contact an Authorized Distributor for Pricing
800.336.LINX www.itwlinx.com www.itwlinx.com
towerMAX
9
AC Protection
towerMAX Series
Bubble of Protection Bubble of Protection
PAGING HORN
SCL/8
PAGING HORN
*
C PERIPHERAL DEVICES
PRINTER
*
L I N E
RS/2
VOICEMAIL PC
L I N E
E Q U I P
RS-232 LINES
towerMAX
TO REMOTE BLDG.
DS/2
E Q U I P
DIGITAL STATION SETS
* *
UTILITY POLE
FAX DIAL-UP MODEM
L I N E
CO/4
E Q U I P
ANALOG LINES
KSU CHASSIS GROUND
*
4 WIRE LEASED LINE CO LINES T1 or LEASED LINES
PC
L I N E
LL/T1
E Q U I P
T1 LEASED LINE
TELCO PRIMARY PROTECTOR AND CONNECTION BLOCK
TO T1
L I N E
CO/4-110
E Q U I P
GROUND
L I N E
CO/25
E Q U I P
C O L I N E S
KSU
S T A T I O N L I N E S
RS-232 LINE
PRINTER PRIMARY PROTECTOR
ON-PREMISE STATION SETS (WITH NO AC CONNECTION)
L I N E
DS/2
E Q U I P
UPS STATION SET
A REMOTE BUILDING
TO PROPERLY GROUNDED OUTLET
* To protect equipment marked (*) additional protectors are required.
x
800.336.LINX www.itwlinx.com 800.336.LINX
Technical Reference
Circuit Technologies Circuit Technologies
ITW LINX INNOVATIVE PROTECTION CIRCUITRY FEATURING:
SurgeGate Plus Circuitry
Protects against prolonged overvoltages and undervoltages by automatically disconnecting the power to your equipment, then reconnecting it when the power has returned to a safe level. This patented circuitry acts as a gate to prevent unsafe voltages from damaging sensitive equipment.
1.) Overvoltage DISCONNECT 2.) Safevoltage RECONNECT
Technical Reference
3.) Undervoltage DISCONNECT 4.) Safevoltage RECONNECT
Protect or Disconnect Circuitry
Protects equipment against all surges. In the event of a catastrophic surge such as lightning, it completely disconnects AC power to the connected equipment and to the protector.
Signal Perfect Circuitry
Auto-resetting surge protection for data networks, telephone and coax lines. This optimized circuitry ensures a clean, clear signal and features solid-state suppressors for maximum protection and reliability.
COAX CABLE
NO INTERFERENCE
COAX CABLE
SIGNAL LINE
AUTO RESET
SIGNAL LINE
92
800.336.LINX www.itwlinx.com 800.336.LINX
Contact an Authorized Distributor for Pricing