A     ccordion 200 Series…by KWIK-WALL, is designed and manufactured to provide
economical sight and sound space division with a traditional, contoured fabric cover fastened to a
three-dimensional welded steel frame. Architectural features include 16-gauge rust-resistant
hinges, positive stops, balanced frame supports and wrinkle-prevention construction. The clear
anodized structural alloy aluminum track system features a lifetime guarantee in the original
installation.


  PRODUCT SERIES GUIDE                          MODEL 208                       MODEL 212

    5000      PLUS PRODUCTS
    3000      STEEL PANEL

    2000      STEEL REINFORCED PANEL

    500       PORTABLE PANEL

    200       ACCORDION PARTITION



 Call: 217-522-5553                     Click: www.kwik-wall.com                    Fax: 217-522-1170
                                                                                                     O P E R AT I O N


Single Operation
KWIK-WALL’s simplest and most popular accordion partition
configuration, Single-type operation consists of one (1) continuous
partition spanning a maximum of 30'-0" (9.1 m). Single partitions
typically latch at one (1) end as standard, but may also latch at both ends
for access flexibility.




Even Pairs Operation
Two (2) accordion partitions of identical size are paired together and latch
at the center of the opening to conveniently divide rooms up to 60'-0"
(18.3 m) in span. Access through the partition is provided at the center of
the partition run, as shown, as well as at one (1) or both ends if required.




                                                                                 Unequal Partition
                                                                                 Height




Uneven Pairs Operation
Uneven Pairs consists of two (2) accordion partitions which are of
unequal width and/or unequal height. This configuration is especially
useful when the partition must conform to an irregular ceiling profile or
when minimizing the partition’s stack depth on one (1) side or the other
is a necessary consideration. Access through the partition is typically
provided at the latch joint of the two (2) partitions. One (1) or both                                             Unequal Partition
partitions of the pair may also latch at the end(s) if desired.
                                                                                                                   Width



KWIK-WALL Company 2                                                                                    Dimensions in [ ] are millimeters.

Call: 217-522-5553                                        Click: www.kwik-wall.com                              Fax: 217-522-1170
PA R T 1 —
G E N E R A L S P E C I F I C AT I O N S
1.01 WORK INCLUDED                                                                    E. ASTM C423: Standard Test Method for Sound Absorption and
       A. The accordion partition shall be furnished, installed and                      Sound Absorption Coefficients by the Reverberation Room
          serviced by the partition manufacturer’s authorized distributor in             Method.
          compliance with architectural drawings and specifications                   F. CCC-W-408A-D: Federal Specification which applies to Vinyl
          contained herein.                                                              Coated Wall Coverings.

1.02 RELATED WORK                                                                     G. CFFA-W-101-B: Chemical Fabrics and Film Association
       A. Structural Support: Structural support system required for                     Quality Standard for Vinyl Coated Fabric Wall Coverings.
          suspending the accordion partition shall be designed and installed
          by others, in accordance with ASTM E557 and manufacturer’s shop         1.06 SUBMITTALS
          drawings.                                                                   A. Manufacturer shall provide written technical information and
                                                                                         related detail drawings which demonstrate that products comply
       B. Insulation: Sound insulation and baffles for the plenum area above             with contract documents for each type of accordion partition
          the track system, under the permanent floor, inside air ducts passing          specified.
          over or around the accordion partition, and in permanent walls
          adjoining the partition shall be by others, in accordance with              B. Manufacturer shall provide detailed engineering drawings
          ASTM E557.                                                                     featuring partition elevation, horizontal details and vertical details
                                                                                         as required.
       C. Opening Preparation: Proper and complete preparation of the
          accordion partition opening shall be by others in accordance with           C. Manufacturer shall provide written test report of the
          ASTM E557, and shall include floor leveling, plumbness of                      independent acoustical testing laboratory showing the attainment
          adjoining permanent walls, substrate and/or ceiling tile enclosures            of the specified STC rating, upon request.
          for the track system, and the painting, finishing of trim and other
                                                                                      D. Manufacturer shall provide written instructions specifying the
          materials adjoining the head and jamb areas of the accordion
                                                                                         proper operation and maintenance of the accordion wall system.
          partition. Any permanent wall(s) receiving a fixed jamb will require
          internal structural blocking in order to secure the jamb to the             E. Manufacturer shall provide a color selector demonstrating the
          permanent wall. Refer to a copy of the shop drawings for additional            manufacturer’s selection of the specified finish material. Samples
          details.                                                                       shall consist of actual swatches of the specified finish material.

1.03 SYSTEM DESCRIPTION                                                           1.07 DELIVERY, STORAGE AND HANDLING
       A. The accordion partition system shall consist of a continuous,               A. Acoustically rated partitions shall be individually wrapped in a
          manually operated, top supported partition as required for straight-           heavy corrugated paper covering to keep the partition clean during
          run room division.                                                             delivery, storage and handling.
       B. The accordion partition shall be acoustically rated in                      B. Partition shall be stored in original crating on cushioned
          accordance with ASTM E90 and ASTM E413 test procedures, and                    blocking in a dry and ventilated area, protected from humidity and
          shall have achieved an STC rating as specified herein (see                     temperature extremes.
          “Acoustical Performance” article listed under Part 2 - Products).
                                                                                  1.08 SEQUENCING / SCHEDULING
1.04 QUALITY ASSURANCE                                                                A. Track Installation: Scheduling of accordion wall track
       A. Acoustical Rating: Accordion partition shall have been tested in               installation shall occur after structural overhead support has been
          an independent acoustical testing laboratory in accordance with                properly and completely fabricated and installed by others.
          ASTM E90 and ASTM E413 test procedures.
                                                                                      B. Partition Installation: Accordion partition installation shall
       B. Fire Rating: The accordion partition finish material shall                     occur after fixed wall substrate construction is properly and
          consist of Class A rated materials in accordance with ASTM E84.                completely installed by others, as required to protect partition from
                                                                                         ongoing adjacent construction.
       C. Installation: The accordion partition shall be installed by the
          manufacturer’s authorized distributor in accordance with ASTM
          E557.                                                                   1.09 WARRANTY
                                                                                      A. Manufacturer’s standard warranty is one (1) year from date of
       D. Single Source Responsibility: Accordion and operable wall                      delivery, when installed by an authorized KWIK-WALL distributor
          systems shall be supplied by a single source manufacturer.                     (see actual warranty on Page 12 for additional details and
                                                                                         limitations).
1.05 REFERENCES
       A. ASTM E90: Laboratory Measurement of Airborne-Sound
          Transmission Loss of Building Partitions.
       B. ASTM E413: Determination of Sound Transmission Class
          (STC).
       C. ASTM E557: Architectural Application and Installation of
          Operable Partitions.
       D. ASTM E84: Surface Burning Characteristics of Building
          Materials.




Dimensions in [ ] are millimeters.                                                                                              KWIK-WALL Company 3
Call: 217-522-5553                                               Click: www.kwik-wall.com                                             Fax: 217-522-1170
                                                                                                  PA R T 2 —
                                                                       P R O D U C T S P E C I F I C AT I O N S
2.01 ACCEPTABLE MANUFACTURER                                                           D. Partition Weight: Maximum partition weight shall be 5.0 lbs./ft.2
     A. Accordion partitions shall be ACCORDION 200 Series, as                            (24 kg/m2) depending on STC rating, size and options selected.
        manufactured by KWIK-WALL Company.                                                Partitions with 44 STC rating will weigh up to 7.0 lbs./ft.2 (34
                                                                                          kg/m2).
2.02 PARTITION CONSTRUCTION
     A. Partition Dimensions: Maximum partition height shall be 16'-0"             2.03 OPERATION
        (4.88 m) and maximum partition span shall be 30'-0" (9.1 m) for                A. Accordion partition shall be manually operated and top
        Single partitions or 60'-0" (18.3 m) for Even Pair partition.                     supported. Operation type shall be (select):
        Partition stack width shall be (select):                                          1. S t a n d a r d S i n g l e O p e r a t i o n : c o n s i s t i n g o f o n e ( 1 )
        1. Model 208: with a stack width profile of 8 1/2" [216] and an                      continuous partition, as required for a maximum partition span
           extended width profile of 5" [127].                                               of 30'-0" (9.1 m).

        2. Model 212: with a stack width profile of 12 1/2" [318] and an                   2. Optional Even Pairs Operation: consisting of two (2)
           extended width profile of 7 1/4" [184].                                            separate partitions. The Even Pairs shall be bi-parting and adjoin
                                                                                              in the center of the partition run, as required for a maximum
     B. Partition Frame: Frame construction shall consist of 16-gauge steel                   partition span of 60'-0" (18.3 m).
        pantograph hinge plates welded to .187" [4.75] diameter vertical
        steel rods. Hinge plates shall have built-in stops to prevent over-                3. Optional Uneven Pairs Operation: consisting of two (2)
        extension spaced no greater than 48" (1.22 m) apart. Sound rated                      separate partitions of unequal size. The Uneven Pairs shall be
        partitions shall include acoustical insulation and internal steel liners              bi-parting and adjoin at a specified point along the partition run,
        on both sides of the frame hinge plates to enhance acoustical                         as indicated on approved shop drawings.
        performance. Internal steel liners shall be (select):
        1. STC 37: 26-gauge steel.                                                 2.04 STACK ARRANGEMENTS
                                                                                       A. Stack Type: Accordion partition storage shall be accomplished by
        2. STC 39 and 41: 22-gauge steel.                                                 (select):
                                                                                          1. Standard Perimeter Stack: as required for applications
        3. STC 44: 18-gauge steel.                                                           whereby the partition shall be stacked along the perimeter of the
                                                                                             room in which it is used.
     C. Partition Cover: Two (2) partition covers consisting of
        laminated substrates shall be internally attached to the frame                     2. Optional Recessed Stack: as required for applications
        assembly. The covers shall provide a durable, impact-resistant and                    whereby the partition shall be stacked within a recessed pocket
        wrinkle-prevention construction, and shall be replaceable at the                      at one (1) or both ends of the partition run.
        project site. Partition covers shall incorporate an air release system
        to allow air to escape from the partition interior when stacking the               3. Optional Combination Stack: as used in conjunction with Even
        partition. Partition cover material shall be factory applied and                      or Uneven Pairs operations whereby a Perimeter Stack is
        consist of (select):                                                                  required on one (1) end of the partition run and a Recessed
        1. Standard Vinyl: consisting of Type II, reinforced vinyl                            Stack is utilized on the opposite end of the partition run.
           weighing 30 oz./lin. yd. (930 g/lin. m). Standard Vinyl shall meet
           or exceed CCC-W-408A-D and CFFA-W-101-B quality                             B. Stack Quantity: The quantity of Stack Arrangements required for
           standards.                                                                     storing the partition shall be (select):
                                                                                          1. Standard Single Stack: as required for a standard Single
        2. Optional Upgrade Carpet: consisting of acoustically                                operation stacking at one (1) end.
           absorbent, non-woven needle punch fibers fused to prevent
           fraying and unraveling of material weighing 23 oz./lin. yd. (713                2. Optional Double Stack: as required for optional Even and
           g/lin. m). Upgrade Carpet shall achieve a minimum NRC rating                       Uneven Pairs operations stacking at both ends of the partition
           of .70 for Non-Rated partitions or .85 for acoustically rated                      run.
           partitions in accordance with ASTM C423.




        MODEL 208 PRODUCT GUIDE                                                                MODEL 212 PRODUCT GUIDE
                                        MAXIMUM MAXIMUM                                                                              MAXIMUM MAXIMUM
         STC             STACK          PARTITION PARTITION                                     STC                STACK             PARTITION PARTITION
        RATING           WIDTH           HEIGHT    WIDTH*                                      RATING              WIDTH              HEIGHT    WIDTH*

      Non-Rated           8 1/2"            16.0"          60'-0"                            Non-Rated              12 1/2"              16.0"             60'-0"
                          [216]           (4.88 m)        (18.3 m)                                                   [318]             (4.88 m)           (18.3 m)
           37             8 1/2"            16.0"          60'-0"                                  41               12 1/2"              16.0"             60'-0"
                          [216]           (4.88 m)        (18.3 m)                                                   [ 318]            (4.88 m)           (18.3 m)
           39             8 1/2"            16.0"          60'-0"                                  44               12 1/2"              16.0"             60'-0"
                          [216]           (4.88 m)        (18.3 m)                                                   [ 318]            (4.88 m)           (18.3 m)

     *Note: Maximum partition span for Single partitions is 30'-0" (9.1 m) or 60'-0" (18.3 m) for Even Pair partitions.



KWIK-WALL Company 4                                                                                                                   Dimensions in [ ] are millimeters.

Call: 217-522-5553                                               Click: www.kwik-wall.com                                                        Fax: 217-522-1170
 PA R T 2 —
 P R O D U C T S P E C I F I C AT I O N S
 2.05 LATCH ARRANGEMENTS                                                                      B. Bottom Seals: Bottom sound seals shall consist of field-
         A. Latch Type: The accordion partition shall be equipped with a                         adjustable, continuous-contact, 3-ply flexible vinyl-felt-vinyl sweep
            latch as required for opening and closing the partition. The latching                seals installed on both sides of the partition cover. (Note: Non-
            mechanism shall be mounted in a Lead Post consisting of 14-gauge                     Rated partitions are provided with 2-ply vinyl seals as an option only
            steel and utilize a grip-type pull assembly with a final pull-in feature.            and must be specified accordingly.)
            Grip handle shall be constructed of architectural grade 6063-T5
            aluminum with a clear satin anodized finish. The type shall be              2.08 ACOUSTICAL PERFORMANCE
            (select):                                                                         A. Certification: A research and development specimen of the
            1. Single Latch: as required for latching a partition to a Fixed                     accordion partition shall have been submitted to and tested in an
               Latch Post at the end(s) of a partition run. The Fixed Latch Post                 independent acoustical testing laboratory and shall have achieved
               shall consist of 6063-T5 structural aluminum alloy and shall                      an STC rating in accordance with ASTM E90 and ASTM E413 test
               mount permanently and directly to a structural wall.                              procedures.
            2. Pairs Latch: as required for latching Even and Uneven Pairs                    B. STC Rating - Model 208: The Model 208 accordion partition
               partitions together within the partition run.                                     acoustical performance shall be (select):
            3. Combination Single and Pairs Latches: as required for latching                    1. Standard 39 STC.
               Even and Uneven Pairs partitions together within the partition                     2. Optional 37 STC or Non-Rated.
               run (Pairs Latch) as well as at one (1) or both ends to a Fixed
               Latch Post (Single Latch). The Fixed Latch Post shall consist of               C. STC Rating - Model 212: The Model 212 accordion partition
               6063-T5 structural aluminum alloy and shall mount permanently                     acoustical performance shall be (select):
               and directly to a structural wall.                                                1. Standard 41 STC.

         B. Latch Quantity - Single Operation: The Single partition shall                         2. Optional 44 STC or Non-Rated.
            include one (1) Single Latch, as standard, for latching the partition
            at one (1) end of the partition run; or two (2) Single Latches, as an       2.09 SUSPENSION SYSTEM
            option, as required for latching the partition at both ends of the                A. Track Type: Standard aluminum track and ceiling guard shall
            partition run.                                                                       be extruded from 6063-T6 structural aluminum alloy with clear
                                                                                                 anodized architectural grade finish, and shall utilize grooves and
         C. Latch Quantity - Even and Uneven Pairs Operation: The                                interlocking pins for positive alignment of adjacent sections. Track
            Paired partition shall include one (1) Pairs Latch, as standard, for                 shall be attached directly to a wood overhead structural support.
            latching the partitions together within the partition run. As an
            additional option, the Pairs partition can also include one (1) or two            B. Track Size: The track size shall be (select):
            (2) Single Latches, as desired for latching one (1) or both ends of                   1. 2 0 8 N o n - A c o u s t i c a l L i t e - D u t y A l u m i n u m Tr a c k :
            the pair at the end(s) of the partition run.                                             certified for Non-Rated Model 208 partitions less than or
                                                                                                     equal to 10'-0" (3.05 m) in height.
 2.06 JAMB ARRANGEMENTS                                                                           2. 208 Acoustical Lite-Duty Aluminum Track w/ Ceiling
         A. Jamb Type: The Accordion partition shall utilize a (select):                             Guard: certified for Non-Rated and acoustically rated Model
            1. Standard Fixed Jamb: consisting of a 14-gauge steel vertical                          208 partitions less than or equal to 10'-0" (3.05 m) in height.
               rail which is covered with matching finish material and attached
               permanently and directly to a structural wall.                                     3. 2 0 8 A c o u s t i c a l S t a n d a r d - D u t y A l u m i n u m Tr a c k w /
                                                                                                     Ceiling Guard: certified for Non-Rated and acoustically rated
            2. Optional Sliding Jamb Panel: consisting of a rigid                                    Model 208 partitions over 10'-0" (3.05 m) in height or Non-
               plywood panel covered with matching finish material. Sound                            Rated Model 212 partitions.
               rated partitions shall have 3-ply flexible vinyl sweep seals
               installed along the top and bottom of the panel. The Sliding                       4. 2 1 2 A c o u s t i c a l S t a n d a r d - D u t y A l u m i n u m Tr a c k w /
               Jamb Panel shall be attached permanently and directly to the                          Ceiling Guard: certified for Non-Rated and acoustically rated
               partition back post and shall move back and forth within the                          Model 212 partitions.
               recessed stack area when extending and retracting the partition.               C. Carrier: The accordion partition shall be supported by a lead carrier
            3. No Jamb Required: the Single, Even Pairs or Uneven Pairs                          consisting of a four (4) ball bearing wheel assembly, and by
               partition shall be configured with Single Latches at both ends of                 intermediate carriers consisting of two (2) ball bearing wheel
               the partition run, thereby negating the requirement for a Fixed                   assemblies attached to every other volute or, to every third center
               or Sliding jamb.                                                                  hinge point for Non-Rated Model 208 partitions less than or equal
                                                                                                 to 10'-0" (3.05 m) in height.
         B. Jamb Quantity - Single Operation: each Single partition shall
            include one (1) jamb as selected above (unless “No Jamb Required”           2.10 ACCESSORIES
            is selected).
                                                                                              A. Accessories including tie-back straps, meeting posts, security lock
         C. Jamb Quantity - Even and Uneven Pairs Operation: each Pairs                          options, foot bolts and surface-mount ceiling guard trim shall be
            partition shall require a total of two (2) jambs as selected above                   compatible with other accessories and options, and shall be
            (unless “No Jamb Required” is selected).                                             furnished by the accordion partition manufacturer.
                                                                                         (NOTE: See Page 11 for complete Accessories specifications and details.)
 2.07 HORIZONTAL SEALS
         A. Top Seals: Top sound seals shall consist of fixed, continuous-
            contact, 3-ply flexible vinyl-felt-vinyl sweep seals installed on both
            sides of the partition cover. (Note: Non-Rated partitions are
            provided with 2-ply vinyl sweep seals as an option only and must be
            specified accordingly.)




Dimensions in [ ] are millimeters.                                                                                                           KWIK-WALL Company 5
Call: 217-522-5553                                                 Click: www.kwik-wall.com                                                         Fax: 217-522-1170
                                                                                  S TA C K A R R A N G E M E N T S
Perimeter Stack
Available in conjunction with Single, Even Pairs and Uneven Pairs operations,
Perimeter Stack arrangements apply to partitions that are stacked along the perimeter
wall within the room in which the partition is used.
     *Stack Depth Dimensions:
        Model 208 (Non-Rated): 1.75" [44] x Finished Opening Width
        Model 208 (STC 37 & 39): 2" [51] x Finished Opening Width
        Model 212 (Non-Rated and STC 41): 1.50" [38] x Finished Opening Width
        Model 212 (STC 44): 1.75" [44] x Finished Opening Width

     Note: Allow additional stack depth for each of the following partition options.

            +3" [76] for each Single Latch
            +5 1/2" [140] for each Pairs Latch
            +1" [25] for each Fixed Jamb
            +6" [152] for each optional Multiple Meeting Post

     Stack Width Dimensions:
        Model 208: 8 1/2" [216]
        Model 212: 12 1/2" [318]




Recessed Stack
For applications that require the accordion to be stacked in a more hidden and discrete
fashion, a Recessed Stack may be utilized. Single partitions can be stored in a Recessed
Stack at either end of the partition run. For Even and Uneven Pairs configured with
Recessed Stacks, the bi-parting partitions would typically be recessed in the stack at
both ends of the partition run.

     *Stack Depth Dimensions:
        Model 208 (Non-Rated): 1.75" [44] x Finished Opening Width
        Model 208 (STC 37 & 39): 2" [51] x Finished Opening Width
        Model 212 (Non-Rated and STC 41): 1.50" [38] x Finished Opening Width
        Model 212 (STC 44): 1.75" [44] x Finished Opening Width

     Note: Allow additional stack depth for each of the following partition options.

            +3" [76] for each Single Latch
            +5 1/2" [140] for each Pairs Latch
            +1 1/2" [38] for Sliding Jamb Panel
            +6" [152] for each optional Multiple Meeting Post

     Stack Width Dimensions:
        Model 208: 13" [330] Finished Pocket Width
                   11" [279] Clearance between Pocket Stops

        Model 212: 17" [432] Finished Pocket Width
                   15" [381] Clearance between Pocket Stops




Combination Perimeter and Recessed Stack
Although not common, it is possible to stack Even and Uneven Pairs partitions using a
combination of Perimeter Stacking at one (1) end of the partition run and Recessed
type stacking at the opposite end. For specific stack area dimensions, please reference
the Perimeter and Recessed Stack sections illustrated above.




KWIK-WALL Company 6                                                                                 Dimensions in [ ] are millimeters.

Call: 217-522-5553                                              Click: www.kwik-wall.com                    Fax: 217-522-1170
 L AT C H A R R A N G E M E N T S
 Single Latch
 Accordion wall systems that consist of a Single partition with a maximum 30'-0" (9.1 m) wall span
 will utilize a Single Latch arrangement at one (1) or both ends of the partition run.




 Pairs Latch
 A Pairs Latch arrangement describes the typical latching condition created when two (2)
 bi-parting partitions (Even or Uneven Pairs) are connected within the partition run.




 Combination Single and Pairs Latches
 Even and Uneven Pairs partition arrangements may feature a combination of Single and Pairs Latches. A Pairs Latch
 is required for adjoining the Paired partitions together within the wall run, while an optional Single Latch may be
 utilized to actively latch the bi-parting partitions at one (1) or both ends of the partition run.




Dimensions in [ ] are millimeters.                                                                              KWIK-WALL Company 7
Call: 217-522-5553                                      Click: www.kwik-wall.com                                       Fax: 217-522-1170
                                                                          JAMB ARRANGEMENTS
Fixed Jamb
For Single operation partitions, one (1) end of the partition may be attached permanently and directly to a Fixed Jamb.
Even and Uneven Pairs partitions also may incorporate a Fixed Jamb at one (1) or both ends of the partition run.




Sliding Jamb Panel
Single operation partitions configured with a Recessed Stack may incorporate a Sliding Jamb Panel as a means of sealing
the partition to the front of a recessed pocket at the stack end of the partition run. Even or Uneven Pairs systems with
Recessed Stacks can use this method at one (1) or both ends of the partition run.




No Jamb Required
An accordion partition system can be configured to allow access at both ends of the partition. By incorporating a Single Latch
at both ends of the partition run, it is possible to eliminate the need for a Fixed or Sliding jamb(s).




KWIK-WALL Company 8                                                                                             Dimensions in [ ] are millimeters.

Call: 217-522-5553                                      Click: www.kwik-wall.com                                           Fax: 217-522-1170
V E R T I C A L D E TA I L S




                                                                  212 Acoustical Standard-Duty
                                                                Aluminum Track w/ Ceiling Guard




                                                                  208 Acoustical Standard-Duty
                                                                Aluminum Track w/ Ceiling Guard




                                                                    208 Acoustical Lite-Duty
                                                                Aluminum Track w/ Ceiling Guard




                                                                 208 Non-Acoustical Lite-Duty
                                                                    Aluminum Track Only


Dimensions in [ ] are millimeters.                                                  KWIK-WALL Company 9
Call: 217-522-5553                   Click: www.kwik-wall.com                           Fax: 217-522-1170
SUSPENSION SYSTEMS & ACCESSORIES




                                                                                X Meeting                  L Meeting                  T Meeting
                                                                                  Post                       Post                       Post
         Aluminum Track w/ Optional Surface
             Mount Ceiling Guard Trim



2.10 ACCESSORIES (Continued from page 6)                                        D. Accessory Security Lock Core Hardware: Optional lock core
     B. Accessory Meeting Posts: Optional meeting post shall be                    hardware shall be a typical interchangeable core cylinder model,
        constructed of 14-gauge steel and covered with matching accordion          furnished without cylinders. Cylinders shall be furnished and
        partition finish material. The “X” and “T” meeting posts shall be          installed by others.
        suspended by one (1) carrier with two (2) ball bearing wheel
        assemblies. The “L” meeting post shall be configured to a Single        E. Accessory Security Heavy Duty Surface Footbolt: Optional heavy
        Latch assembly and suspended by one (1) carrier with four (4) ball         duty security footbolt shall be constructed of architectural grade
        bearing wheel assemblies. A Fixed Latch Post consisting of 6063-T5         aluminum. The security bolt shall allow 1" [25] extra long throw for
        structural aluminum alloy shall be included for creating a positive        added security. The bolt shall be surface mounted to the lead post.
        interlock between the meeting post and adjoining partition(s). The         The bolt shall include a hard rubber grip foot for interfacing with
        Meeting Post configuration shall be (select):                              various floor surfaces.
        1. “X” Meeting Post: with four (4) Fixed Latch Posts, one
            mounted on each side of the Meeting Post, as required for           F. Accessory Pendant Pulls: Pendant Pulls shall be furnished as a
            partitions joining together from four (4) sides.                       factory standard for Even Pairs and Uneven Pairs partition heights of
                                                                                   10'-0" (3.05 m) and over, and shall be optional for partitions which
        2. “L” Meeting Post: with one (1) Fixed Latch Post, mounted at a           are under 10'-0" (3.05 m) in height. The pendant pull shall be
           right angle to the other, as required for partitions joining            located in the lead post of the inactive Pairs Latch, and constructed
           together at right angles from two (2) sides.                            of tubular steel with a powder-coated aluminum finish, as required
                                                                                   for assisting with pulling taller partitions.
        3. “T” Meeting Post: with three (3) Fixed Latch Posts as
           required for partitions joining together from three (3) sides.       G. Accessory Draw Latch: Draw Latch shall be furnished as a
                                                                                   factory standard for partition heights of 10'-0" (3.05 m) and over,
     C. Accessory Security Dead Bolt Lock Hardware: Optional dead bolt             and shall be optional for partitions which are under 10'-0" (3.05 m)
        security hardware shall consist of a conventional cylinder dead bolt       in height. Pulls shall be constructed of tubular steel with a powder-
        with typical “C” type key cylinder, finished in US 26 D Dull               coated aluminum finish and mounted on the lead post(s) of the
        Chromium Plated. The dead bolt hardware arrangement shall be               partition(s), as required for assisting with pulling and latching taller
        (select):                                                                  partitions.
        1. Cylinder Lock Both Sides.
                                                                                H. Accessory Surface Mount Ceiling Guard Trim: Optional trim shall
        2. Cylinder Lock Reference Side, Thumb Turn Back Side.                     consist of 6063-T5 aluminum alloy with clear anodized
                                                                                   architectural grade finish, as may be required for surface mounted
        3. Cylinder Lock Back Side, Thumb Turn Reference Side.                     track applications. Ceiling Guard Trim shall extend 1 3/4" [44] from
                                                                                   the ceiling line.




 KWIK-WALL Company 10                                                                                                   Dimensions in [ ] are millimeters.

Call: 217-522-5553                                            Click: www.kwik-wall.com                                           Fax: 217-522-1170
SUSPENSION SYSTEMS & ACCESSORIES

PART 3 - EXECUTION
3.01 INSPECTION                                                                  3.03 ADJUSTING AND CLEANING
      A. Proper and complete preparation of the operable wall system                 A. The operable wall panels and track system shall be adjusted and
         opening shall be by others in accordance with the architectural                cleaned in accordance with manufacturer’s written instructions.
         drawings, manufacturer’s shop drawings and ASTM E557. Any
         deviation of the actual opening from these specifications shall be      3.04 PROTECTION
         called to the attention of the architect prior to installation of the       A. The operable wall panels shall be stored in the stacked (retracted)
         operable wall.                                                                 position prior to acceptance by the owner’s representative.
      B. Deficiencies in the operable wall opening shall be corrected by
         others prior to installation of the operable wall.
                                                                                 3.05 DEMONSTRATION
                                                                                     A. The operable wall manufacturer’s authorized distributor shall
                                                                                        demonstrate proper operation and explain proper and necessary
3.02 INSTALLATION
                                                                                        maintenance requirements of the operable wall system to the owner’s
      A. The operable wall system shall be installed by manufacturer’s
                                                                                        representative.
         authorized distributor.
      B. The operable wall shall be installed in accordance with
         manufacturer’s written instructions, shop drawings and ASTM E557
         installation guidelines.




Dimensions in [ ] are millimeters.                                                                                          KWIK-WALL Company 11
Call: 217-522-5553                                               Click: www.kwik-wall.com                                         Fax: 217-522-1170
       KWIK-WALL COMPANY LIMITED WARRANTY
       KWIK-WALL Company warrants each Room Divider partition and its component parts to be free from defects in
       material and workmanship for a period of one (1) year from date of delivery to the original purchaser, when installed
       by an authorized KWIK-WALL distributor (see actual warranty on Page 3 for details and limitations). KWIK-WALL
       Company reserves the right to have authorized personnel inspect any part alleged to be defective and to refuse any
       returned material unless the return was previously authorized by KWIK-WALL.

       This warranty does not apply to any damage or deterioration caused by abuse or failure to provide reasonable
       and necessary maintenance. KWIK-WALL’s liability hereunder is limited to the replacement of any partition or
       component part found to be defective. Labor charges are the responsibility of the customer.

       KWIK-WALL SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES.
       ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF
       MERCHANTABILITY ARE HEREBY EXPRESSLY EXCLUDED.

       Some states do not allow the exclusion or limitation of consequential or incidental damages, so the above limitation
       or exclusion may not apply to you.

       This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

       Due to ongoing research and development, some variation may occur in product specifications and design.
       Please refer to your actual shop drawing(s) for exact product dimensions and specifications.




KWIK-WALL Mailing address:                                                                         KWIK-WALL Shipping address:
                                     Distributed By:
P.O. Box 3267                                                                                      1010 E. Edwards Street
Springfield, IL 62708                                                                              Springfield, IL 62703




email: kwinfo@kwik-wall.com      ¥     Call: (217) 522-5553      ¥     Fax: (217) 522-1170     ¥    Internet: www.kwik-wall.com

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:22
posted:8/11/2011
language:English
pages:12