									Lighting Controls
LCP3000EZ
LCP3000EZ Catalog Numbering System

Accessories

11

Catalog No. 5WG1 70 -8X
Enclosure Height 3 = 24" (up to 16 relays = 2 output (relay) modules) 4 = 32" (up to 32 relays = 4 output (relay) modules) 5 = 40" (up to 48 relays = 6 output (relay) modules) Panel Designation A, B, C, D, E, F, G, H, J or K Number of Input Modules Select 0, 8, 16, 24 or 32 inputs. Divide the number of inputs by 8 to get the number to enter at this location. i.e. 24 inputs / 8 = 3.

-Z

LIGHTING CONTROLS

Number of Output Modules 1 to 6 (8 outputs per module; i.e. 48 outputs / 8 outputs per module = 6 output modules).

Enclosure Options Blank = None 1 = Flush Mounting Kit 2 = Key Lock 3 = Key Lock and Flush Mounting Kit

To format the LCP3000EZ catalog number proceed as follows: 1. Enclosure Height: Determine the number of relays and provisions for future relay additions your installation requires. Round the number up to the nearest multiple of 8 (relays come in blocks of 8 relays). - 8 to 16 outputs (relays) enclosure height is 24". Enter 3 in the Enclosure Height field - 24 to 32 outputs (relays) enclosure height is 32". Enter 4 in the Enclosure Height field - 40 to 48 outputs (relays) enclosure height is 40". Enter 5 in the Enclosure Height field 2. Panel designation: First panel is A, second panel is B, third panel is C, etc. Last panel is K. There is no Panel I. 3. Number of input Modules: Determine the number of inputs your system requires and round the number up to the nearest multiple of 8 (input modules are packaged as 2 blocks of 4; therefore, they are supplied in groups of 8). Divide the number of inputs by 8 to determine the number of input modules: - 8 inputs: enter 1 in the Number of Input Modules field - 16 inputs: enter 2 in the Number of Input Modules field - 24 inputs: enter 3 in the Number of Input Modules field - 32 inputs: enter 4 in the Number of Input Modules field 4. Number of output (relay) modules: Determine the number of relays, and provisions for future relay additions your installation requires; then round the number up to the nearest 8 (relays come in blocks of 8 relays). Divide the number of relays by 8 to determine the number of output (relay) modules:

- 8 relays: enter 1 for Number of Output (relay) Modules field - 16 relays: enter 2 in the Number Output (relay) Modules field - 24 relays: enter 3 in the Number Output (relay) Modules field - 32 relays: enter 4 in the Number Output (relay) Modules field - 40 relays: enter 5 in the Number Output (relay) Modules field - 48 relays: enter 6 in the Number Output (relay) Modules field

32/8 = 4. Enter 4 in the Number of Output (relay) Modules field. of of of of of Second Panel: 5. Enclosure height: Number of outputs (relays) = 44, round up to the nearest multiple of 8 which is 48. 48/8 = 6. Enter 5 in the Enclosure Height field. 6. Panel designation: This is the second panel. Enter B in the Panel Designation field. 7. Number of input modules: Number of inputs = 31, round up to the nearest multiple of 8 which is 32. 32/8 = 4. Enter 4 in the Number of Input Modules field. 8. Number of output (relay) modules: Number of relays = 42 round up to the nearest multiple of 8 which is 48. 48/8 = 6. Enter 6 in the Number of Output (relay) Modules field. Applicable to all panels: 9. Enclosure options: Key lock required. Enter 2 in the Enclosure Options field. Finalized catalog numbers: First panel is: 5WG1 704-8XA34-Z2 Second panel is: 5WG1 705-8XB46-Z2 External options After you have finished with the LCP3000EZ catalog number, select any external options for the project. i.e.: - Motion sensors (two SIEMENS motion sensors are supported per panel). Third party motion sensors with dry contacts can be used; This type is used in conjunction with the Input Modules - Outdoor light sensor (one is supported by each network of 10 panels - Override or key switch (you may select this option, although the binary inputs can also be used for this purpose - Web Access software (ComBridge Studio) - OPC interface - E-mail services - Data Base services 11-3

5. Enclosure options: Determine if key lock, flush mounting kit of both are required. - No option required: leave the Enclosure Options field blank - Flush mount kit: enter 1 in the Enclosure Options field - Key lock: enter 2 in the Enclosure Options field - Key lock and flush mount kit: enter 3 in the Enclosure Options field Example: A system needs two panels: The first panel requires 20 inputs and 30 outputs (relays). The second panel requires 31 inputs and 44 outputs (relays). Key lock is required in both panels. First Panel: 1. Enclosure height: Number of outputs (relays) = 30, round up to the nearest multiple of 8 which is 32. 32/8 = 4. Enter 4 in the Enclosure Height field. 2. Panel designation: This is the first panel. Enter A in the Panel Designation field. 3. Number of input modules: Number of inputs = 20, round up to the nearest multiple of 8 which is 24. 24/8 = 3. Enter 3 in the Number of Input Modules field 4. Number of output (relay) modules: Number of relays = 30 round up to the nearest multiple of 8 which is 32.