Suction Type              Oily Water Separator

           ing with
   Comply           –
            llenges
  new cha             m
             the 5 pp
  fulfilling
                 d!
        standar
                                                                                    SKIT/S-DEB 0.5

    Oil/Water Separation
    The RWO oil/water separation system type SKIT/S-DEB
    complies with the actual IMO Resolution MEPC.107(49), using
    the combination of the well known SKIT/S highly effective
    open porous coalescer with automatic backflushing, together
    with a second stage newly developed emulsion breaking oil
    and hydrocarbon polisher.

    The periodical backflushing keeps the coalescer surface
    clean and offers long lasting operation without attendance
    and lowest maintenance.

    The excellent and long experience with the RWO coalescing
    type oily water separator guarantees a high performance
    standard. More than 10,000 ships have already been
    equipped with this efficient system.
                                                                                        SKIT/S-DEB 2.5




                                                    The system comes as a complete package, skid
                                                    mounted with all necessary accessories and controls
                                                    and providing the following benefits:

                                                        exceptionally high purity levels < 1 ppm oil
                                                        content in the effluent under IMO conditions
                                                        USCG type approval certified
                                                        EMV-Electromagnetic Compliance
                                                        Class Notations “Clean Design” and Alaska-Rules
                                                        conformity
                                                        Process Unit upgrade and retrofitting of RWO separators
                                                        SKIT/S to comply with IMO-MEPC.107(49) possible
                                                        easy to install and easy to handle

                  SKIT/S-DEB 5.0                        worldwide service & support


2
                                       Features
                                       To extend the operating life of the demulsifier, an automatic bypass is fitted to the
                                       separating system. The 15 ppm oil content measuring device periodically checks
                                       the water quality of the first stage separator and, if below 15 ppm, the demulsifier
                                       is bypassed until the 15 ppm alarm is activated. This process control causing a
                                       considerable life cycle prolongation.




Oil content monitor
The RWO oily water separating system is equipped with the 15 ppm oil content alarm device,
type tested and approved in accordance with IMO Resolution MEPC.107(49).
The 3-way cock for flushing is fitted with a contact to ensure that during flushing of the alarm
device, the 3-way diverting valve is in recirculation mode (automatic stopping device). According
to IMO Resolution MEPC.107(49) an extra 3-way valve is installed downstream of the oily water
separator in the overboard line to recirculate the water to the bilge whenever required during
Port State Control.



                                                                                       Complying with new
                                                                                       challenges – fulfilling
                                                                                       the 5 ppm standard!




                                                                                                                             3
 Technical Data SKIT/S-DEB
                                                                                                                                            Empty
                      Capacity                                                                                                  Power
   Type                  3             A         B        C              D        E       F+G                  H+I                          weight
                       (m /h)                                                                                                    kW
                                                                                                                                             kg
    0.1                 0.1           1100      715      650             –        –   610+260=870               500                0.5       86
    0.25                0.25          1120      1075     770         822     380      750+300=1050          530+260=790            2.0       185
    0.5                 0.5           1170      1190     720         870     350      860+350=1210          780+510=1290           2.7       230
    1.0                 1.0           1280      1325     820        1040     450      1060+385=1445         780+510=1290           2.7       260
    1.5                 1.5           1545      1455     870        1185     500      1265+430=1695     1035+510=1545              2.7       340
    2.5                 2.5           1780      1515     1095       1225     750      1420+600=2020         780+510=1290           3.0       510
    5.0                 5.0           2000      1935     1350       1625     1050     1610+600=2210     1295+510=1805              4.0       850
    10.0                10.0          2415      2410     1560       1880     1300     1895+600=2495     1315+510=1825              4.5      1200
- Data are subject to change without further notice -


                                                                                                      55A
                  5              10        17                 42
                                                                                                      55B       2    Power supply
                                                                                                      23B
                                                                                                                3    Control box

                                                                   25B                                          4    Oil discharge
                                                                                                                5    Backwashing outlet
              3
                                                                                                                9    Sensor electrode
                                                                   47        14                       47
                                                                                                               10    Electrical heating
              2
                                                                                                               14    Mono pump
           25A
                                                                                                               15    Backwashing inlet
                                                                             15
                                                                                                               17    15 ppm oil alarm monitor

         22                                                                                                    22    Bilge water inlet
                                                                                                               23B   Recirculation to bilge tank
                          9
                                                                                                               25A   Sample water inlet

     5
                                                                                                               25B   Flushing water inlet
                                                                                                               42    IMO-sample cock
     4
                                                                                                               47    Polisher
                                                                                                               55A   Discharge to overboard
    10
                                                                                                               55B   Recirculation to bilge tank
                                                  15




                                                       RWO GmbH
                                                       MARINE WATER TECHNOLOGY
                                                       Thalenhorststrasse 15 A
                                                                                                                                                     Stand 12.2010




                                                       28307 Bremen/Germany
                                                       Phone: +49 421 537050
                                                       Fax:    +49 421 53705440
                                                       rwo@veoliawater.com
                                                       www.rwo.de     www.veoliawater.com

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:32
posted:7/27/2011
language:English
pages:4