									                                                             MINIMUM GARAGE DOOR SHEAR PANELS
                                                               ALTERNATE BRACING REQUIREMENTS

                                         16" MINIMUM PANEL WIDTH
  DOUBLE STUDS ARE REQUIRED FROM
  THE BOTTOM PLATE TO THE TOP PLATE
                                                                         DOUBLE STUDS FULL LENGTH
                                                  FULL LENGTH
                                                  DOUBLE STUDS
                                           +
STRAP LENGTH 23 1/8"             23 1/8"                                                  NOT TO SCALE
                                           +
                                                                   +

                                           +
                                                                                                           AT EACH CORNER OF GARAGE WALLS WITH
                                                                   +
                                                                                                           GARAGE DOOR OPENINGS A 48" SHEAR PANEL IS REQUIRED.
                                                                                                           AREAS NOT ALLOWING A 48" SHEAR PANEL AN ALTENATE
                                                                   +
                                                                                                           PANAL MAY BE USED.

                                                                                                           16" WIDE PANELS (16" TO 48")
                                                                                                           2 SINMPSON STHD10 STRAPS AE REQUIRED AT EACH PAEN.
             SIMPSON STRONG-TIE
             STHD10                                                                                        A MINIMUM APA RATED SHEATHING APPLIED ON ONE SIDE
             NAILED OFF WITH 16d NAILS
                                                                                                           OF THE PANEL FROM THE BOTTOM PLATE TO THE TOP
                                                                                                           PLATE WITH 8d COMMON OR GALV. NAILS 3" O.C.
                                                                           CORNER DISTANCE FROM
                                                                           EDGE OF STRAP TO                WALLS EXCEEDING 8' IN HEIGHT REQUIRE SOLID BLOCKING
             HEADERS MUST RUN TO EACH                                      CORNER IS 1 1/2"                AT THE JOINTS THE HEADER MUST RUN TO THE END OF
             END OF THE SHERE PANEL                                                                        EACH PANEL.
                                                             16 INCHES MINIMUM

                                                         + + + + + + + + +
                                                         + + + + + + + + +
                                                         + + + + + + + + +       HEADER

                                                          ++                ++
                                                          ++                ++
                                                          ++                ++
                           SHEAR PANEL NAIL-OFF                                  3/8" MINIMUM SHEATHING
                                                          ++                ++
                                                          ++                ++   8d SHEATHING NAIL-OFF 3" O.C. EACH WAY
                                                          ++                ++
                                                          ++                ++


                  SHEAR PANELS LESS THAN 16" IN WIDTH REQUIRES PROFESSIONAL ENGINEERING
                                                        @ CITY OF KALISPELL BUILDING
                                                           DEPARTMENT DETAILS

								