					                                    Existing Building(s) Lighting Project-Level Summary
This worksheet calculates the annual energy savings and Conservation Rate Credit or Conservation Acquisition Agreement
reimbursement resulting from the installation of energy efficient lighting. The project-level economics including savings after HVAC
interaction, busbar savings, O&M costs or savings, and periodic lamp replacement costs or savings, PV Life Cycle Cost and TRC B/C
ratio are also calculated.

No data on this sheet may be edited.
Enter all data on the Site Audit (Start Here) tab. Inputs here reflect data entered on that tab.
  Calculator Last Revised>              2/9/2009               Version 1.7e              Todays Date>>>              7/15/2011
  Project & Facility Name>           Project Name                                        Customer Name
  Facility Street Address>           Street Address                                          Building>       0
  Facility City, State, Zip>         City                                                   Select State                 ZIP
  Utility Invoice # & NameUtility Invoice Number               Utility Name                  Account #                 acct. #
Line No.                                               INPUTS FROM SITE AUDIT TAB
        1                          Total Floor Area Affected by Project (# of fixtures x 64 sqft/fixture)                0 sf
        2         Project/Measure Change in Cleaning/Other O&M Cost (Savings -$ or Increases +$)                        $0.00
        3                                                                     Dominant Building Type             Select building type
        4                                                            Primary Space Heat Fuel Source                Unconditioned
        5                                   Total Existing Kilowatt-Hours of Area Affected by Retrofit                  0 kWh
        6                                 Total Proposed Kilowatt-Hours of Area Affected by Retrofit                    0 kWh
        7                                      Total Estimated Annual kWh Site Savings (unadjusted)                     0 kWh
        8                                                                                  Project Cost                 $0.00
        9      Project-Level Net PV of Periodic Lamp Replacement Cost (Savings -$ or Increases +$)                      $0.00
      10                                        Default Hours of Lighting Operation for Building Type                  0 hours
      11                                         RESULTS FOR ADDING PROJECT TO CART
      12                                                                                  Measure Life                           0 years
      13                      Inferred Weighted Average Hours of Operation (kWh saved/ kW saved)                                       0
      14      Lighting Savings Yield (HVAC Interaction Adjustment for Building & Space Heat Type)                                    0%
      15                            Annual Site Energy Savings Adjusted for HVAC Interaction (kWh)                                0 kWh
      16                        Annual Busbar Energy Savings Adjusted for HVAC Interaction (kWh)                                  0 kWh
      17                                                                 Kilowatt-Hour Reduction (%)
       18                                                                        Customer Retail Rate                       $0.000 /kWh
       19                                                               Annual Energy Cost Savings                                  $000
       20                                            Project Simple Payback (Excluding Any Rebate)                             0.0 years
       21                                                          Site Unit Energy Savings (kWh/sf)                              0 kWh
       22                                         Site Lighting Power Density (lpd) Reduction (W/sf)                       0.00 Watts/sf
       23                                                   Unit Value of Electric Savings (NPV/kWh)                              $0.000
       24                                                              Present Value Energy Savings                                   $0
       25                                                             Present Value of Energy Costs                                   $0
       26                                        Unit Value of Gas Heat Interaction (NPV/kWh saved)                             $0.0000
       27          Present Value of Change in Cleaning/Other O&M Cost (Savings -$ or Increases +$)                                    $0
       28                  Present Value of Change in Gas Heating Cost (Savings -$ or Increases +$)                                   $0
       29              Present Value Life Cycle Lamp Replacement Cost (Savings -$ or Increases +$)                                    $0
       30           Present Value Project/Measure Change in O&M Cost (Savings -$ or Increases +$)                                     $0
       31                                                                     Project Life Cycle Cost                                 $0
       32                                                                  Project Benefit/Cost Ratio                            Infinite
       33                                                          Total BPA Credit/ Reimbursement                                 $0.00
                                                                      Existing Building(s) Lighting Spreadsheet Tool - Updated February 9, 2009

                    Project Name:         Project Name                                                                                                    Utility Invoice Number:          Utility Invoice Number
         Dominant Building Type:      Select building type                                                                                                         Serving Utility:        Utility Name
         Space Heat Fuel Source:      Unconditioned                                                                                                         Utility Contact Name:          Utility Contact Name
                  Customer Name           Customer Name                                                                                                  Utility Phone Number:             Utility Phone
                   Contact Name:          Contact Name                                                                            Energy Rate ($/kWh) & estimated $ savings/yr:                $0.00                    $0.00         CUSTOMER SIMPLE PAYBACK:
          Facility Street Address:        Street Address                                                                          Demand Rate ($/kW) & estimated $ savings/yr:                 $0.00                     $0             0.0     years
                     Facility City:       City                                                                                    Audit Prepared By (Name and Phone Number):               Auditor Info
              Facility State & Zip:       Select State                             ZIP                                                              Trade Ally/Contractor Name:            Trade Ally Name
      Building & Account Number                                                acct. #                                                        Date & Time (fills in automatically):        7/15/11 6:09 PM


                                                                                                                                            Total Estimated Annual kWh Site                Annual Hours           Kilowatt-Hour         Total kWh Site Savings
                                        Total Existing Kilowatt-Hours                    Total Proposed Kilowatt-Hours
                                                                                                                                                  Savings (unadjusted)                      (weighted)         Reduction Percentage      (adjusted for HVAC)
     Summary Table >>
                                                              0                                         0                                                    0                                                                                     0

                                                             Project Cost>>                       $0                                       Lesser of Credit/Reimbursement -or- 70% Project Cost>>                                     $0

          Location                       Existing Lamp/Ballast Combination                                  Notes:                            Proposed Lamp/Ballast Combination                                Summary/Design Info            Measure Info
                                                                                                  For high performance lamps
                                                                                                  and ballasts on the CEE list,
                                                                                                  include model numbers and
                            Annual                                                        Mean    CEE list date. Field notes on   Annual                                                          Mean  Annual   kWh    Light
     For instance; building Operat                                                 Watts Lumens    fixtures, mounting height,     Operat                                                   Watts Lumens  kWh    Reduct Level                    $ per
        and room name       Hours          Existing Lamp/Ballast              Q'ty Each   Each     difficulty, approvals, etc…    Hours        Proposed Lamp/Ballast                  Q'ty Each   Each  Savings   ion  Change          Code      unit   Total     $

 1


 2


 3


 4


 5


 6


 7


 8


 9


10


     TOTALS>>>                                                                 0                                                                                                       0                            0                                        $0




           051c1535-625b-4f28-9bb9-b39651853898.xls                                                                                                                                                                                    7/15/2011, 6:09 PM
     Street Address: Street Address                                          Project Name: Project Name
        Facility City: City                                                      Invoice # : Utility Invoice Number

   Existing                                                                                 Incentive Number          Total by
                                   Measure Description
  Equipment                                                                                  Per Unit of Units        Measure
                   A High Performance T8 or T5 Lamp and Ballast (New or Retrofit)
                       Includes T8 & NLO T5, 2' to 8' lamps: Ballast: PF > 95%, THD < 20%. Lamp: Lumen Maint. > 94%,
T12 Fluorescent,       CRI > 80, lamp life > 24,000 hours, Initial System Lumens/Watt > 95. Note: All lamps and ballasts on
                       CEE's High Performance products list qualify. Refer to the following link: http://www.cee1.org/

 T8 De-Lamp,       1   Upgrade to 1 lamp with high performance electronic ballast               $20
                   2   Upgrade to 2 - 4 lamps with high performance electronic ballast          $40
 Incandescent,     B Standard T8 or T5 Lamp and Ballast (New or Retrofit)
                       Includes T8 and T5, 2' to 8' lamps. Ballast: PF > 90%, THD < 20%. Lamp: Lumen Maint. > 90%,
       or
                        CRI > 80 , 4' lamp life > 20,000 hours, Initial System Lumens/Watt > 80.
 Mercury Vapor     1     Upgrade to 1 lamp with standard electronic ballast                  $10
                   2     Upgrade to 2 - 4 lamps with standard electronic ballast             $20
                   C Hardwired Compact Fluorescent (New Fixture or Retrofit kit)
                     Includes both typical hardwired (any shape) or GU-24 base, See Energy Star for guidance, CRI > 80.
                   1    49 Watts or less (Nominal Lamp Watts)                                   $40
 Incandescent      2     50 or more Watts (Nominal Lamp Watts)                                  $80
                   D Ceramic Metal Halide (New Fixture)
       or            CRI > 80, lamp life > 10,000 hours.
                   1   99 Watts or less (Nominal Lamp Watts)                                $80
 Mercury Vapor     2   100 or more Watts (Nominal Lamp Watts)                              $150
                   E Screw-in Lamps (Lamp Only)
       or           Energy Star compliant where applicable. Includes CFL and Cold Cathode.
                   1   CFL or Cold Cathode - 1 to 24 Watts                                     $3
                   2   CFL or Cold Cathode - 25 to 45 Watts                                    $6
 HO/VHO T12        3   CFL or Cold Cathode - over 45 watts                                    $12
                   F LED or Cold Cathode (New Fixture or Retrofit kit)
                    Energy Star compliant where applicable. F2 includes the LR-6 type kit or equivalent.
       or          1    Upgrade incandescent sign to LED or cold cathode                        $50
                   2    Upgrade incandescent recessed cans or track heads to LED                $30
  HPS / LPS        G Induction (New Fixture)
                     Lamp Life > 60,000 hours, CRI > 80, can include retrofit kit that has been bench tested.
                   1     99 Watts or less (Nominal Lamp Watts)                              $80
                   2     100 or more Watts (Nominal Lamp Watts)                            $150
                   H High Output (high-bay) Fluorescent (New Fixture)
                     Includes T8, T5, bi-ax T5 ; 1'-8'. Ballast: PF > 90%, THD < 20%. Lamp: Lumen Maint. > 90%, C RI > 80,
 HO/VHO T12          lamp life > 18,000 hours, Initial System Lumens/Watt > 80.
      or           1   40 to 129 Watts (1-2 lamp T5) or equivalent T8                    $120
MV / HPS / LPS     2   130 to 189 Watts (3 lamp T5) or equivalent T8                     $140
      or           3   190 to 249 Watts (4 lamp T5) or equivalent T8                     $160
  Probe-Start      4   250 Watts and above (5 - 12 lamp T5) or equivalent T8             $180
  Metal Halide     I Pulse-Start or Electronic Metal Halide (New Fixture)
      or            Lamp Life > 20,000 hours, Lumen Maint. > 75%, CRI > 65, Initial System Lumens/Watt > 89.
 Incandescent      1      200 to 399 Watts (Nominal Lamp Watts)                                $150
                   2      400 Watts and above (Nominal Lamp Watts)                             $200
                     J Occupancy Sensors, Timers, Photocells, and Control Panels
                      Includes infrared, ultrasonic, & dual-technology sensors and/or Timers, Photocells, and Control Panels.
Manual Control
                     1     50 to 200 Watts controlled                                           $35
                     2     over 200 Watts controlled                                            $60
                     K Retrofit High Output Fixtures with T8 Lamps & Ballasts
                       Includes lamp/ballast retrofits & kits; Ballast: PF > 90%, THD < 20%. Lamp: 8' or 4' T8 Slimline or HO.
8' T12 HO/VHO
                       Lumen Maint. > 90%, CRI > 80, lamp life > 18,000 hours, Initial System Lumens/Watt > 80 .
 4' HO de-lamp   1     1 T8 8' lamp and standard electronic ballast                     $40
                 2     (2 to 8) 4' T8 lamps and standard electronic ballast             $80
                 L Retrofit Very High Output Fixtures Date: Lamps & Ballasts
Inspected By:____________________________________ with T5___________
Inspected By:____________________________________ Date: ___________ < 20%. Lamp: 4' T5 HO. Lumen Maint. > 90%,
                   Includes lamp/ballast retrofits only; Ballast: PF > 90%,THD
    8' T12
                   CRI > 80, lamp life > 20,000 hours, Initial System Lumens/Watt > 80.
      VHO            1   2 T5 lamps and high output ballast                                               $50
                     2   3 to 4 T5 lamps and high output ballast                                         $100
                     M Other "one time" measure with pre-approval from BPA
                         Includes lighting measures that are not on the above list (A-L). One-time deemed credit/reimbursement can be
  Any existing
                         given to measures that receive pre-approval from BPA.
    condition        1      Put measure description here and deemed value in next cell>>
                     2      Put measure description here and deemed value in next cell>>
                                                                                                  A. Incentive Item Total ($):   $0
                                                                                                       B. Total Project Cost:    $0
                                                                                                     C. 70% of Project Cost      $0
                                                                   D. Reimbursement/Credit = Lower of "A" or "C" above:          $0
                                                                Percent (%) Kilowatt-Hour Reduction:
Inspected By:____________________________________ Date: ___________             Annual kWh Savings:                               0
Inspected By:____________________________________ Date: ___________

Useful Information
1. Has the installed equipment met the project requirements and specifications?                                     (yes/no)
2. Are the measures listed properly installed and operating?                                                        (yes/no)
3. Has the Sub-Project achieved a 25% or greater kWh reduction?                                                     (yes/no)
4. Have invoices been labeled with the unique identifying number from the RTF reporting system?                     (yes/no)




Completed By:________________________________________________                                              Date:       7/15/11 6:09 PM
                               UTILITY or TRADE ALLY NAME
                                    COMPANY ADDRESS
                                COMPANY CITY, STATE, Zip
                                COMPANY PHONE NUMBERS

                                           July 15, 2011


Customer Name
Street Address
City     Select State   ZIP


Dear:    Contact Name

Attached is a completed lighting energy audit of:    Project Name



                                        The bid for this project:              $0.00
                                      Estimated Utility Incentive:            $0.00
               Your Estimated net cost after the Utility Incentive:            $0.00
                        Estimated kilowatt-hour savings per year:                     0 kwh
          Estimated money lost every year the project is delayed:                    $0
                    Estimated percent lighting wattage reduction:                         Lighting Only
                         Estimated Return on Investment (ROI):                   0% per year
                          For a simple payback for the project of:               0.0 years



I have attached a copy of the program requirements and specifications for your review.
In order to receive a utility rebate, you need to follow these program requirements.

If you have any questions regarding this proposal, please call;       Auditor Info

We look forward to working with you on this important project.


Sincerely,




Auditor Info
                                                                         Existing Building(s) Lighting Spreadsheet Tool - Updated February 6, 2009

                       Project Name:         Measure Examples (copy & paste)                                                                                           Utility Invoice Number:
         Dominant Building Type:         Retail Mini Mart                                                                                                                        Serving Utility:         NW Public Power
         Space Heat Fuel Source:         Electric Resistance                                                                                                             Utility Contact Name:            Manie Hats
                  Customer Name              Bob's Grocery Store                                                                                                    Utility Phone Number:                 530-456-9876
                    Contact Name:            Bob Marley                                                                                      Energy Rate ($/kWh) & estimated $ savings/yr:                    $0.063                    $0           Customer Simple Payback:
           Facility Street Address:          1212 SW Rastafarian Avenue                                                                      Demand Rate ($/kW) & estimated $ savings/yr:                     $2.220               $3,022               0.0 years
                        Facility City:       Jamaica                                                                                         Audit Prepared By (Name and Phone Number):                   Craig Ciranny 503-230-5865
               Facility State & Zip:         California                            97897                                                                         Trade Ally/Contractor Name:              Exodus Lighting, Inc.
      Building & Account Number              Main Store                               2345                                                                Date & Time (fills in automatically):           7/15/11 6:09 PM


                                                                                                                                                        Total Estimated Annual kWh Site                   Annual Hours           Kilowatt-Hour     Total kWh Site Savings
                                           Total Existing Kilowatt-Hours                      Total Proposed Kilowatt-Hours
                                                                                                                                                              Savings (unadjusted)                         (weighted)         Reduction Percentage  (adjusted for HVAC)
     Summary Table >>
                                                               152,261                                       38,808                                                    113,454                                4,374                     75%                         0

                                                                Project Cost>>                        $18,050                                           Lesser of Credit/Reimbursement -or- 70% Project Cost>>                                 $7,555

          Location                          Existing Lamp/Ballast Combination                                Notes (Optional):                            Proposed Lamp/Ballast Combination                                   Summary/Design Info           Measure Info
                                                                                                     field notes on existing or
                              Annual                                                         Mean proposed fixture type, mounting Annual                                                                         Mean  Annual kWh    Light
     For instance; building   Operat                                                  Watts Lumens  height, difficulty, approvals, Operat                                                                 Watts Lumens  kWh    Reduc Level      $ per
        and room name         Hours           Existing Lamp/Ballast              Q'ty Each   Each                etc…              Hours                    Proposed Lamp/Ballast                    Q'ty Each   Each  Savings tion Change Code unit                    Total     $
   Measure A2 Example                                                                                                                              High Performance T8, 2-4' lamps with
                                         T12 4' Fluorescent, 2-40 Watt Lamps,
 1 (copy and paste these       3,500                                             50      96   4,868                                          3,500 Reduced Light Output ballast. Consult CEE's       50       48      4,594    8,400    50%   -6%     A2      $40        $2,000
                                         Magnetic Ballast
   examples)                                                                                                                                       qualifying products list.
                                         Incandescent Exit Sign, 2-20 Watt                                2 entrace doors and 4 interior
 2 Measure F1 Example          8,760                                              6      40      2                                           8,760 New LED Exit Sign                                  6       3        2       1,945    93%   0%      F1      $50         $300
                                         Lamps                                                                        signs
                                                                                                                                                   New LED Recessed Downlight or tracklight
 3 Measure F2 Example          3,500 Incandescent, 1-65 Watt PAR Lamp            24      65    608                                           3,500                                                   24       12       650     4,452    82%   7%      F2      $30         $720
                                                                                                                                                   (LR6 or equivalent)
                                     High Pressure Sodium, 200 Watt
 4 Measure G2 Example          4,380                                              4     245   18,040         cobra head style fixture        4,380 Induction, 165 Watt globe-shaped lamp              4      165      9,600    1,402    33%   -47%    G2      $150        $600
                                     Lamp
 5 Measure H2 Example          5,000 Metal Halide, 400 Watt Lamp                 10     458   26,000              sealed fixture             5,000 4 Lamp T5 High Output (high bay) New Fixture 10           234    19,000    11,200    49%   -27%    H3      $160       $1,600

                                                                                                                                                     3 Lamp T5 High Output (high bay) New Fixture
     Measure H4 & J2                                                                                    mounting height 30' need a lift to
 6                             5,000 Mercury Vapor, 400 Watt Lamp                 5     454   19,100                                         2,100 with fixture-mounted occupancy sensor              5      179    14,250     9,471    83%   -25%   H2/J1 $175           $875
     Example                                                                                                        install
                                                                                                                                                     (reduce proposed operating hours accordingly)

                                     High Pressure Sodium, 400 Watt                                                                                Metal Halide, 320 Watt Lamp, Electronic
 7 Measure I1 Example          4,380                                              4     457   41,000         cobra head style fixture        4,380                                                    4      344    29,240     1,980    25%   -29%     I1     $150        $600
                                     Lamp                                                                                                          Ballast
                                     T12 8' Fluorescent, 2-215 Watt VHO                                                                            4 Lamp T8 4' with High Light Output ballast
 8 Measure K2 Example          6,000                                             10     440   19,051 4 lamp retrofit kit including reflector 4,000                                                   10      148    13,547    20,480    78%   -29%    K2      $80         $800
                                     Lamps, Magnetic Ballast                                                                                       (Upgrade from T12 HO/VHO)
                                                                                                                                                   Occupancy Sensor, Timer, Photocell, or
   Measure J2 Sensor
                                                                                                         ceiling-mounted occupancy                 Control Panel controlling the above fixtures
 9 Example for the above                                                                                                                                                                              1       0        0                              J2      $60         $60
                                                                                                            sensor. Ceiling is 12'                 (over 200 watts) (reduce proposed operating
   fixtures
                                                                                                                                                   hours accordingly)
   Measure M1 Example                                                                                 received pre approval from BPA,
                                         T12 5' Fluorescent, 1-75 Watt HO                                                                          New LED refrigerator case light (3 watts per                                                               call
10 with pre approval from      5,500                                             10      90   4,212   lumens is on a per-foot basis for      5,500                                                   50       3        195     4,125    83%   -77%    M1
                                         Lamp, Magnetic Ballast                                                                                    linear foot - input linear feet as quantity)                                                               BPA
   BPA                                                                                                           this measure
   Decommission Fixture                                                                                                                            Decommission (Permanently Remove)
11                             1,000 Halogen, 500 Watt                            2     500   8,550                                            0                                                      2       0        0       1,000    100% -100%    N/A      $0          $0
   Example                                                                                                                                         Lighting Fixture
12 Leave as is Example         4,000 High Pressure Sodium, 200 Watt              50     245   18,040                                         4,000 No recommendation (leave fixture as-is)           50       0        0      49,000 100% -100%       N/A      $0          $0
                                     Lamp
13

     TOTALS>>>                                                                   175                                                                                                                 216                      113,454                                    $7,555




            051c1535-625b-4f28-9bb9-b39651853898.xls                                                                                                                                                                                            7/15/2011, 6:09 PM
                                                                             Mean
                                                                    Input   System
 Description of Existing Lamp/Ballast Combination                   Watts   Lumens         Suggested Upgrades / Notes

Describe existing lamp/ballast combination here                                      <<Input a wattage and mean system lumens
=================================
EXIT SIGNS
=================================
Incandescent Exit Sign, 2-5 Watt Lamps                               10       2      New LED Exit Sign
Incandescent Exit Sign, 2-8 Watt Lamps                               16       2      New LED Exit Sign
Incandescent Exit Sign, 2-10 Watt Lamps                              20       2      New LED Exit Sign
Incandescent Exit Sign, 2-15 Watt Lamps                              30       2      New LED Exit Sign
Incandescent Exit Sign, 2-20 Watt Lamps                              40       2      New LED Exit Sign
Incandescent Exit Sign, 2-25 Watt Lamps                              50       2      New LED Exit Sign
Incandescent Exit Sign, 2-40 Watt Lamps                              80       2      New LED Exit Sign
=================================
T8 DE-LAMP
=================================
Standard 4' T8 2 lamp 32 Watt                                        60     4932
Standard 4' T8 3 lamp 32 Watt                                        90     6969
Standard 4' T8 4 lamp 32 Watt                                       114     9293
Standard 4' T8 6 lamp 32 Watt                                       162     15373
=================================
T12 FLUORESCENT (LAMPS UNDER 8')
=================================
T12 2' Fluorescent, 1-20 Watt Lamp, Magnetic Ballast                 24       960    T8 High Performance
T12 3' Fluorescent, 1-30 Watt Lamp, Magnetic Ballast                 36      1630    T8 High Performance
T12 2'x2' Fluorescent, 1-40 Watt U-Tube Lamp, Magnetic Ballast       48      2775    T8 High Performance
T12 2'x2' Fluorescent, 2-40 Watt U-Tube Lamps, Magnetic Ballast      86      5550    T8 High Performance
T12 4' Fluorescent, 1-56 Watt HO Lamp, Magnetic Ballast              66      4000    T8 High Performance
T12 4' Fluorescent, 2-56 Watt HO Lamps, Magnetic Ballast            132      8000    T8 High Performance
----------------------------
T12 4' Fluorescent, 1-34 Watt ES Lamp, Energy Efficient Ballast      43      1891    T8 High Performance
T12 4' Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast         46      2434    T8 High Performance
T12 4' Fluorescent, 1-34 Watt ES Lamp, Magnetic Ballast              48      1934    T8 High Performance
T12 4' Fluorescent, 1-40 Watt Lamp, Magnetic Ballast                 52      2434    T8 High Performance
----------------------------
T12 4' Fluorescent, 2-34 Watt ES Lamps, Energy Efficient Ballast     72      3781    T8 High Performance
T12 4' Fluorescent, 2-34 Watt ES Lamps, Magnetic Ballast             82      3868    T8 High Performance
T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast        88      4868    T8 High Performance
T12 4' Fluorescent, 2-40 Watt Lamps, Magnetic Ballast                96      4868    T8 High Performance
----------------------------
T12 4' Fluorescent, 3-34 Watt ES Lamps, Energy Efficient Ballasts   116      5672    T8 High Performance
T12 4' Fluorescent, 3-34 Watt ES Lamps, Magnetic Ballasts           130      5802    T8 High Performance
T12 4' Fluorescent, 3-40 Watt Lamps, Energy Efficient Ballasts      134      7302    T8 High Performance
T12 4' Fluorescent, 3-40 Watt Lamps, Magnetic Ballasts              148      7302    T8 High Performance
----------------------------
T12 4' Fluorescent, 4-34 Watt ES Lamps, Energy Efficient Ballasts   144      7562    T8 High Performance
T12 4' Fluorescent, 4-34 Watt ES Lamps, Magnetic Ballasts           164      7736    T8 High Performance
T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts      176      9736    T8 High Performance
T12 4' Fluorescent, 4-40 Watt Lamps, Magnetic Ballasts              192      9736    T8 High Performance
=================================
T12 FLUORESCENT (8' LAMPS)
=================================
T12 8' Fluorescent, 1-60 Watt Lamp, Magnetic Ballast                 83      4259    T8 High Performance
T12 8' Fluorescent, 1-75 Watt Lamp, Magnetic Ballast                100      5145    T8 High Performance
T12 8' Fluorescent, 1-95 Watt HO ES Lamp, Magnetic Ballast          125      5729    T8 High Performance
T12 8' Fluorescent, 1-100W HO Lamp, Magnetic Ballast                140      6716    T8 High Performance
T12 8' Fluorescent, 1-185 Watt VHO ES Lamp, Magnetic Ballast        200      8370    T8 High Performance
T12 8' Fluorescent, 1-215 Watt VHO Lamp, Magnetic Ballast           230      9526    T8 High Performance
----------------------------
T12 8' Fluorescent, 2-60 Watt ES Lamps, Energy Efficient Ballast    123     8322 T8 High Performance
T12 8' Fluorescent, 2-60 Watt ES Lamps, Magnetic Ballast            138     8517 T8 High Performance
T12 8' Fluorescent, 2-75 Watt Lamps, Energy Efficient Ballast       158     10181 T8 High Performance
T12 8' Fluorescent, 2-75 Watt Lamps, Magnetic Ballast                 173    10290    T8 High Performance
T12 8' Fluorescent, 2-95 Watt HO ES Lamps, Magnetic Ballast           227    11458    T8 High Performance
T12 8' Fluorescent, 2-110 Watt HO Lamps, Energy Efficient Ballast     237    13432    T8 High Performance
T12 8' Fluorescent, 2-110 Watt HO Lamps, Magnetic Ballast             252    13432    T8 High Performance
T12 8' Fluorescent, 2-185 Watt VHO ES Lamps, Magnetic Ballast         325    16740    T8 High Performance
T12 8' Fluorescent, 2-215 Watt VHO Lamps, Magnetic Ballast            440    19051    T8 High Performance
----------------------------
T12 8' Fluorescent, 3-60 Watt ES Lamps, Magnetic Ballasts             220    12776    T8 High Performance
T12 8' Fluorescent, 3-75 Watt Lamps, Magnetic Ballasts                274    15435    T8 High Performance
T12 8' Fluorescent, 3-95 Watt HO ES Lamps, Magnetic Ballasts          352    17186    T8 High Performance
T12 8' Fluorescent, 3-110 Watt HO Lamps, Energy Efficient Ballasts    392    20148    T8 High Performance
----------------------------
T12 8' Fluorescent, 4-60 Watt ES Lamps, Energy Efficient Ballast     246     16643    T8 High Performance
T12 8' Fluorescent, 4-60 Watt ES Lamps, Magnetic Ballast             276     17035    T8 High Performance
T12 8' Fluorescent, 4-75 Watt Lamps, Energy Efficient Ballasts       316     20361    T8 High Performance
T12 8' Fluorescent, 4-75 Watt Lamps, Magnetic Ballasts               346     20580    T8 High Performance
T12 8' Fluorescent, 4-95 Watt HO ES Lamps, Energy Efficient Ballasts 416     22915    T8 High Performance
T12 8' Fluorescent, 4-95 Watt HO ES Lamps, Magnetic Ballasts         454     22915    T8 High Performance
T12 8' Fluorescent, 4-110 Watt HO Lamps, Energy Efficient Ballasts   474     26864    T8 High Performance
T12 8' Fluorescent, 4-110 Watt HO Lamps, Magnetic Ballasts           504     26864    T8 High Performance
T12 8' Fluorescent, 4-185 Watt VHO ES Lamps, Magnetic Ballasts       650     33480    T8 High Performance
T12 8' Fluorescent, 4-215 Watt VHO Lamps, Magnetic Ballasts          880     38102    T8 High Performance
=================================
T12 FLUORESCENT (OTHER)
=================================
T12 Other Fluorescent, 1-20 Watt Lamp, Magnetic Ballast                25      944    T8 High Performance
T12 Other Fluorescent, 1-25 Watt ES Lamp, Magnetic Ballast             42     1514    T8 High Performance
T12 Other Fluorescent, 1-30 Watt Lamp, Magnetic Ballast                46     1791    T8 High Performance
T12 Other Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast        48     2234    T8 High Performance
----------------------------
T12 Other Fluorescent, 2-20 Watt Lamps, Magnetic Pre-Heat Ballast      50     1887    T8 High Performance
T12 Other Fluorescent, 2-25 Watt ES Lamps, Energy Efficient Ballast    66     3027    T8 High Performance
T12 Other Fluorescent, 2-30 Watt Lamps, Magnetic Pre-Heat Ballast      74     3581    T8 High Performance
T12 Other Fluorescent, 2-25 Watt ES Lamps, Magnetic Ballast            74     3027    T8 High Performance
T12 Other Fluorescent, 2- 30 Watt Lamps, Magnetic Ballast              79     3334    T8 High Performance
T12 Other Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast       86     4469    T8 High Performance
----------------------------
T12 5' Fluorescent, 1-75 Watt HO Lamp, Magnetic Ballast                90    4212     T8 High Performance
T12 5' Fluorescent, 2-75 Watt HO Lamps, Magnetic Ballast              180    8424     T8 High Performance
T12 6' Fluorescent, 1-85 Watt HO Lamp, Magnetic Ballast               102    5063     T8 High Performance
T12 6' Fluorescent, 2-85 Watt HO Lamps, Magnetic Ballast              204    10126    T8 High Performance
=================================
METAL HALIDE
=================================
Metal Halide, 50 Watt Lamp                                              62    2006    Hard-Wired CFL, 1-32 Watt Lamp (new fixture)
Metal Halide, 70 Watt Lamp                                              90    2950    Hard-Wired CFL, 2-26 Watt Lamps (new fixture)
Metal Halide, 100 Watt Lamp                                            129    5440    Hard-Wired CFL, 2-42 Watt Lamps (new fixture)
Metal Halide, 150 Watt Lamp                                            185    8640    Hard-Wired CFL, 4-26 Watt Lamps (new fixture)
Metal Halide, 175 Watt Lamp                                            210    9400    2 Lamp T5 High Output (high bay) New Fixture
Metal Halide, 250 Watt Lamp                                            295    11300   3 Lamp T5 High Output (high bay) New Fixture
Metal Halide, 320 Watt Lamp                                            378    14464   3 Lamp T5 High Output (high bay) New Fixture
Metal Halide, 400 Watt Lamp                                            458    26000   4 Lamp T5 High Output (high bay) New Fixture
Metal Halide, 1000 Watt Lamp                                          1080    78000   Metal Halide Pulse Start, 750 Watt
Metal Halide, 1500 Watt Lamp                                          1605   132000   Metal Halide Pulse Start, 1000 Watt
=================================
INCANDESCENT
=================================
Incandescent, 1-15 Watt Typical Bulb                                   15       95    Screw-In CFL, 5 Watt
Incandescent, 1-25 Watt Typical Bulb                                   25      170    Screw-In CFL, 7 Watt
Incandescent, 1-40 Watt Typical Bulb                                   40      403    Screw-In CFL, 9 Watt
Incandescent, 1-50 Watt Typical Bulb                                   50      429    Screw-In CFL, 13 Watt
Incandescent, 1-60 Watt Typical Bulb                                   60      800    Screw-In CFL, 15 Watt
Incandescent, 1-75 Watt Typical Bulb                                   75     1086    Screw-In CFL, 20 Watt
Incandescent, 1-100 Watt Typical Bulb                                 100     1548    Screw-In CFL, 26 Watt
Incandescent, 1-150 Watt Typical Bulb                                 150     2537    Screw-In CFL, 42 Watt
----------------------------
Incandescent, 2-15 Watt Typical Bulbs              30      191    Screw-In CFL, 2-5 Watt
Incandescent, 2-25 Watt Typical Bulbs              50      340    Screw-In CFL, 2-7 Watt
Incandescent, 2-40 Watt Typical Bulbs              80      805    Screw-In CFL, 2-9 Watt
Incandescent, 2-50 Watt Typical Bulbs             100      858    Screw-In CFL, 2-13 Watt
Incandescent, 2-60 Watt Typical Bulbs             120     1600    Screw-In CFL, 2-15 Watt
Incandescent, 2-75 Watt Typical Bulbs             150     2171    Screw-In CFL, 2-20 Watt
Incandescent, 2-100 Watt Typical Bulbs            200     3096    Screw-In CFL, 2-26 Watt
Incandescent, 2-150 Watt Typical Bulbs            300     5073    Screw-In CFL, 2-42 Watt
----------------------------
Incandescent, 4-40 Watt Typical Bulbs             160     1610    Screw-In CFL, 4-9 Watt
Incandescent, 4-60 Watt Typical Bulbs             240     3199    Screw-In CFL, 4-15 Watt
Incandescent, 4-75 Watt Typical Bulbs             300     4342    Screw-In CFL, 4-20 Watt
Incandescent, 4-100 Watt Typical Bulbs            400     6192    Screw-In CFL, 4-26 Watt
----------------------------
Incandescent, 1-65 Watt PAR Lamp                   65      608    New LED Downlight (recessed can, LR6 or equivalent)
Incandescent, 75 Watt Reflector Lamp               75      801    New LED Downlight (recessed can, LR6 or equivalent)
Incandescent, 90 Watt Reflector Lamp               90     1071    Screw-in Ceramic Metal Halide (self-ballasted)
Incandescent, 100 Watt Reflector Lamp             100     1071    Screw-in Ceramic Metal Halide (self-ballasted)
Incandescent, 120 Watt Reflector Lamp             120     1440    Ceramic Metal Halide, 1-39 Watt PAR Lamp
Incandescent, 150 Watt Reflector Lamp             150     1710    Ceramic Metal Halide, 1-39 Watt PAR Lamp
----------------------------
Incandescent, 1-200 Watt Bulb                     200     3154    Screw-In CFL, 42 Watt
Incandescent, 1-300 Watt Bulb                     300     4802    Screw-In CFL, 85 Watt
Incandescent, 1-500 Watt Bulb                     500     8811    T8 High Performance
Incandescent, 1-620 Watt Bulb                     620     9350    T8 High Performance
=================================
HALOGEN
=================================
MR-16 or MRC-16 Halogen Display Lamps, 20 Watts    20      240    Screw-in LED
MR-16 or MRC-16 Halogen Display Lamps, 35 Watts    35      490    Screw-in LED
MR-16 or MRC-16 Halogen Display Lamps, 40 Watts    40      600    Screw-in LED
MR-16 or MRC-16 Halogen Display Lamps, 50 Watts    50      790    Screw-in Ceramic Metal Halide (self-ballasted)
MR-16 or MRC-16 Halogen Display Lamps, 75 Watts    75     1320    Screw-in Ceramic Metal Halide (self-ballasted)
----------------------------
Halogen, 100 Watt                                  100   1440     Screw-in Ceramic Metal Halide (self-ballasted)
Halogen, 150 Watt                                  150   2160     Ceramic Metal Halide, 1-39 Watt PAR Lamp
Halogen, 250 Watt                                  250   3600     Ceramic Metal Halide, 1-70 Watt PAR Lamp
Halogen, 300 Watt                                  300   4680     Ceramic Metal Halide, 1-100 Watt PAR Lamp
Halogen, 500 Watt                                  500   8550     Ceramic Metal Halide, 1-150 Watt Lamp (single or double end)
Halogen, 750 Watt                                  750   13500    Metal Halide Pulse Start, 200 Watt Lamp
Halogen, 1000 Watt                                1000   18900    Metal Halide Pulse Start, 200 Watt Lamp
Halogen, 1500 Watt                                1500   29700    Metal Halide Pulse Start, 350 Watt Lamp
=================================
HIGH PRESSURE SODIUM
=================================
High Pressure Sodium, 35 Watt Lamp                  45    1845    None
High Pressure Sodium, 50 Watt Lamp                  68    3280    None
High Pressure Sodium, 70 Watt Lamp                  86    5166    None
High Pressure Sodium, 100 Watt Lamp                120    7790    1 Lamp T5 High Output (high bay) New Fixture
High Pressure Sodium, 150 Watt Lamp                170    13120   1 Lamp T5 High Output (high bay) New Fixture
High Pressure Sodium, 200 Watt Lamp                245    18040   2 Lamp T5 High Output (high bay) New Fixture
High Pressure Sodium, 250 Watt Lamp                295    22550   3 Lamp T5 High Output (high bay) New Fixture with fixture-mounted occup
High Pressure Sodium, 310 Watt Lamp                365    30340   4 Lamp T5 High Output (high-bay) New Fixture with fixture-mounted occup
High Pressure Sodium, 400 Watt Lamp                457    41000   6 Lamp T5 High Output (high-bay) New Fixture with fixture-mounted occup
High Pressure Sodium, 1000 Watt Lamp              1100   114800   12 Lamp T5 High Output (high bay) New Fixture
=================================
MERCURY VAPOR
=================================
Mercury Vapor, 100 Watt Lamp                       125   3400     T8 High Performance
Mercury Vapor, 175 Watt Lamp                       205   7600     T8 High Performance
Mercury Vapor, 250 Watt Lamp                       285   10700    T8 High Performance
Mercury Vapor, 400 Watt Lamp                       454   19100    T8 High Performance
Mercury Vapor, 1000 Watt Lamp                     1080   45000    T8 High Performance
=================================
ENTER OTHER LAMP/BALLAST COMBINATIONS
=================================
                                    Explain in notes field on site audit tab if necessary
                                    Explain in notes field on site audit tab if necessary
                                    Explain in notes field on site audit tab if necessary
                                    Explain in notes field on site audit tab if necessary
=================================
                                                                                        Mean
                                                                                 Input System Measure Rebate
   Description of Proposed Lamp/Ballast Combination                              Watts Lumens Category Amount


Add qualifying measure(s) here. See the technical specifications for guidance.
No recommendation (leave fixture as-is)                                                              N/A       $0
Decommission (Permanently Remove) Lighting Fixture                                0        0         N/A       $0
=================================
HIGH PERFORMANCE T8 or NLO T5 LAMP and BALLAST (New Fixture or Retrofit)
=================================
32 Watt Lamps
----------------------------
                                                                             25        2297
High Performance T8, 1-4' lamp with Reduced Light Output ballast. Consult CEE's qualifying products A1
                                                                                                    list.     $20
High Performance T8, 1-4' lamp with Normal Light Output ballast. Consult CEE's28        2592         A1
                                                                               qualifying products list.      $20
                                                                              32        2945
High Performance T8, 1-4' lamp with High Light Output ballast. Consult CEE's qualifying products list. A1     $20
----------------------------
                                                                             48       4594         A2
High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.      $40
                                                                                55      5183          A2
High Performance T8, 2-4' lamps with Normal Light Output ballast. Consult CEE's qualifying products list.       $40
High Performance T8 Stairwell or Parking Lot Light, 2-4' lamps with Normal Light60      5183        A2/J1       $75
                                                                                Output ballast and fixture-mounted occupancy sensor (reduce
                                                                                74
High Performance T8, 2-4' lamps with High Light Output ballast. Consult CEE's qualifying6774          A2
                                                                                         products list.         $40
----------------------------
                                                                              96        9587         A2         $40
High Performance T8, 2-8' 54 Watt lamps with Normal Light Output ballast, 96 Watt typical, System efficacy >95 lumens per Watt
                                                                             110     10199
High Performance T8, 2-8' lamps with Normal Light Output ballast, 110 Watt Max, System efficacy >95A2       $40
                                                                                                   lumens per Watt
----------------------------
                                                                             72       6803         A2
High Performance T8, 3-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.    $40
                                                                             81        7686         A2
High Performance T8, 3-4' lamps with Normal Light Output ballast. Consult CEE's qualifying products list.     $40
High Performance T8, 3-4' lamps with High Light Output ballast. Consult CEE's 110      10160          A2
                                                                              qualifying products list.       $40
----------------------------
                                                                             95       9071         A2
High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list.    $40
                                                                             108      10249         A2
High Performance T8, 4-4' lamps with Normal Light Output ballast. Consult CEE's qualifying products list.     $40
High Performance T8, 4-4' lamps with High Light Output ballast. Consult CEE's 148      13547          A2
                                                                              qualifying products list.       $40
----------------------------
25 Watt Lamps
----------------------------
                                                                             38      3474
High Performance T8, 2-4' 25 Watt lamps with Reduced Light Output ballast. Consult CEE's qualifyingA2        $40
                                                                                                   products list.
                                                                             58      5211
High Performance T8, 3-4' 25 Watt lamps with Reduced Light Output ballast. Consult CEE's qualifyingA2        $40
                                                                                                   products list.
                                                                             77      6948
High Performance T8, 4-4' 25 Watt lamps with Reduced Light Output ballast. Consult CEE's qualifyingA2        $40
                                                                                                   products list.
----------------------------
T5 Normal Light Output Lamps
----------------------------
                                                                            58
New High Performance NLO T5, 2-4' lamps with Normal Light Output ballast (New Fixture5235
                                                                                     or Retrofit)    A2       $40
=================================
RETROFIT HO/VHO T12 FIXTURES to T8 LAMPS & BALLASTS
=================================
4 Lamp T8 4' with Normal Light Output ballast (Upgrade from T12 HO/VHO)          108    10249        K2       $80
4 Lamp T8 4' with High Light Output ballast (Upgrade from T12 HO/VHO)            148    13547        K2       $80
6 Lamp T8 4' with Normal Light Output ballast (Upgrade from T12 HO/VHO)          162    15373        K2       $80
6 Lamp T8 4' with High Light Output ballast (Upgrade from T12 HO/VHO)            222    21027        K2       $80
8 Lamp T8 4' with Normal Light Output ballast (Upgrade from T12 HO/VHO)          216    20497        K2       $80
8 Lamp T8 4' with High Light Output ballast (Upgrade from T12 HO/VHO)            296    27094        K2       $80
=================================
HIGH OUTPUT (high-bay) FLUORESCENT (Install New Fixture)
=================================
High Output T5 New Fixtures
----------------------------
1 Lamp T5 High Output (high bay) New Fixture                                 62       4750       H1         $120
2 Lamp T5 High Output (high bay) New Fixture                                 118      9500       H1         $120
                                                                             118      9500      H1/J1       $155
2 Lamp T5 High Output (high bay) New Fixture with fixture-mounted occupancy sensor (reduce proposed operating hours accordingly)
3 Lamp T5 High Output (high bay) New Fixture                                 179      14250      H2         $140
                                                                             179      14250 H2/J1           $175
3 Lamp T5 High Output (high bay) New Fixture with fixture-mounted occupancy sensor (reduce proposed operating hours accordingly)
4 Lamp T5 High Output (high bay) New Fixture                                 234      19000      H3         $160
                                                                             234      19000 H3/J2           $220
4 Lamp T5 High Output (high-bay) New Fixture with fixture-mounted occupancy sensor (reduce proposed operating hours accordingly)
5 Lamp T5 High Output (high bay) New Fixture                                 298      23750      H4         $180
6 Lamp T5 High Output (high bay) New Fixture                                 352      28500      H4         $180
                                                                             352      28500 H4/J2           $240
6 Lamp T5 High Output (high-bay) New Fixture with fixture-mounted occupancy sensor (reduce proposed operating hours accordingly)
8 Lamp T5 High Output (high bay) New Fixture                                 472      38000      H4         $180
12 Lamp T5 High Output (high bay) New Fixture                                704      57000      H4         $180
2 Lamp T5 High Output (high-bay) fluorescent (Retrofit kit)                  118      9500        L1         $50
4 Lamp T5 High Output (high-bay) fluorescent (Retrofit kit)                  234      19000       L2        $100
----------------------------
High Output T8 New Fixtures
----------------------------
                                                                               8
3 Lamp T8 4' High Output (high bay) New Fixture with Normal Light Output Ballast 1      7686       H1        $120
3 Lamp T8 4' High Output (high bay) New Fixture with High Light Output Ballast 111      10160      H1        $120
                                                                               108
4 Lamp T8 4' High Output (high bay) New Fixture with Normal Light Output Ballast        10249      H1        $120
4 Lamp T8 4' High Output (high bay) New Fixture with High Light Output Ballast 148      13547      H2        $140
                                                                               162
6 Lamp T8 4' High Output (high bay) New Fixture with Normal Light Output Ballast        15373      H2        $140
6 Lamp T8 4' High Output (high bay) New Fixture with High Light Output Ballast 222      21027      H3        $160
                                                                               216
8 Lamp T8 4' High Output (high bay) New Fixture with Normal Light Output Ballast        20497      H3        $160
8 Lamp T8 4' High Output (high bay) New Fixture with High Light Output Ballast 296      27094      H4        $180
=================================
STANDARD T8 or T5 LAMP and BALLAST (New Fixture or Retrofit)
=================================
1 Lamp
----------------------------
Standard 2' T8 1 lamp 17 Watt 80+CRI lamp, (1-F17T8)                           16     1103         B1         $10
                                                                               27
Standard 4' T8 1 lamp 32 Watt 80+CRI lamp with Reduced Light Output ballast, (1-F32T8)1991         B1         $10
                                                                               31
Standard 4' T8 1 lamp 32 Watt 80+CRI lamp with Normal Light Output ballast, (1-F32T8) 2400         B1         $10
----------------------------
2 Lamp
----------------------------
                                                                             51       4316
Standard 4' T8 2 lamp 32 Watt 80+CRI lamp with Very Reduced Light Output ballast, (2-F32T8)         B2          $20
                                                                               55
Standard 4' T8 2 lamp 32 Watt 80+CRI lamp with Reduced Light Output ballast, (2-F32T8)4372          B2          $20
                                                                               59
Standard 4' T8 2 lamp 32 Watt 80+CRI lamp with Normal Light Output ballast, (2-F32T8) 4932          B2          $20
                                                                               65      4932       B2/J1         $55
Standard T8 Stairwell or Parking Lot Light, 4' T8 2 lamp 32 Watt 80+CRI lamp with Normal Light Output ballast and fixture-mounted occupancy
                                                                              105
Standard 8' T8 2 lamp 59 Watt 80+CRI lamp with Normal Light Output ballast, (2-F96T8) 9027          B2          $20
----------------------------
3 Lamp
----------------------------
                                                                              80
Standard 4' T8 3 lamp 32 Watt 80+CRI lamp with Reduced Light Output ballast, (3-F32T8)5974         B2         $20
                                                                               90
Standard 4' T8 3 lamp 32 Watt 80+CRI lamp with Normal Light Output ballast, (3-F32T8)   6969       B2         $20
----------------------------
4 Lamp
----------------------------
                                                                              98
Standard 4' T8 4 lamp 32 Watt 80+CRI lamp with Reduced Light Output ballast, (4-F32T8)7728         B2         $20
                                                                              114
Standard 4' T8 4 lamp 32 Watt 80+CRI lamp with Normal Light Output ballast, (4-F32T8)   9293       B2         $20
=================================
HARDWIRED COMPACT FLUORESCENT New Fixture or Retrofit kit (includes GU-24)
=================================
Hard-Wired CFL, 1-13 Watt Lamp (new fixture)                                     16     765        C1         $40
Hard-Wired CFL, 1-18 Watt Lamp (new fixture)                   19    1063    C1   $40
Hard-Wired CFL, 1-26 Watt Lamp (new fixture)                   27    1530    C1   $40
Hard-Wired CFL, 1-32 Watt Lamp (new fixture)                   33    2040    C1   $40
Hard-Wired CFL, 1-42 Watt Lamp (new fixture)                   43    2720    C1   $40
----------------------------
Hard-Wired CFL, 2-13 Watt Lamps (new fixture)                  29    1530    C1   $40
Hard-Wired CFL, 2-18 Watt Lamps (new fixture)                  38    2125    C1   $40
Hard-Wired CFL, 2-26 Watt Lamps (new fixture)                  54    3060    C2   $80
Hard-Wired CFL, 2-28 Watt Lamps (new fixture)                  58    2965    C2   $80
Hard-Wired CFL, 2-32 Watt Lamps (new fixture)                  68    3398    C2   $80
Hard-Wired CFL, 2-42 Watt Lamps (new fixture)                  93    5440    C2   $80
----------------------------
Hard-Wired CFL, 4-13 Watt Lamps (new fixture)                  58    3060    C2   $80
Hard-Wired CFL, 4-18 Watt Lamps (new fixture)                  76    4250    C2   $80
Hard-Wired CFL, 4-26 Watt Lamps (new fixture)                  108   6120    C2   $80
Hard-Wired CFL, 4-42 Watt Lamps (new fixture)                  186   10880   C2   $80
=================================
CERAMIC METAL HALIDE (New Fixture)
=================================
Ceramic Metal Halide, 1-20 Watt Lamp (single end)              28    1100    D1    $80
Ceramic Metal Halide, 1-39 Watt Lamp (single or double end)    45    2600    D1    $80
Ceramic Metal Halide, 1-70 Watt Lamp (single or double end)    80    5200    D1    $80
Ceramic Metal Halide, 1-150 Watt Lamp (single or double end)   168   10200   D2   $150
Ceramic Metal Halide, 1-50 Watt Bulb                           55    2640    D1    $80
Ceramic Metal Halide, 1-70 Watt Bulb                           80    4700    D1    $80
Ceramic Metal Halide, 1-100 Watt Bulb                          112   6800    D2   $150
Ceramic Metal Halide, 1-150 Watt Bulb                          168   9920    D2   $150
Ceramic Metal Halide, 1-39 Watt PAR Lamp                       45    1600    D1    $80
Ceramic Metal Halide, 1-70 Watt PAR Lamp                       80    3840    D1    $80
Ceramic Metal Halide, 1-100 Watt PAR Lamp                      112   5440    D2   $150
=================================
SCREW-IN LAMPS (Lamp Only)
=================================
Screw-In CFL, 3 Watt                                            3     128    E1   $3
Screw-In CFL, 5 Watt                                            5     213    E1   $3
Screw-In CFL, 7 Watt                                            7     327    E1   $3
Screw-In CFL, 9 Watt                                            9     421    E1   $3
Screw-In CFL, 13 Watt                                          13     680    E1   $3
Screw-In CFL, 14 Watt                                          14     720    E1   $3
Screw-In CFL, 15 Watt                                          15     791    E1   $3
Screw-In CFL, 18 Watt                                          18     978    E1   $3
Screw-In CFL, 20 Watt                                          20    1020    E1   $3
Screw-In CFL, 22 - 24 Watt (includes circline)                 23    1190    E1   $3
----------------------------
Screw-In CFL, 25 - 27 Watt                                     26    1488    E2   $6
Screw-In CFL, 28 - 32 Watt (includes circline)                 30    1530    E2   $6
Screw-In CFL, 35 - 36 Watt (includes circline)                 36    1785    E2   $6
Screw-In CFL, 40 - 42 Watt (includes circline)                 41    2380    E2   $6
----------------------------
Screw-In CFL, 55 Watt                                          55    2975    E3   $12
Screw-In CFL, 65 Watt                                          65    3570    E3   $12
Screw-In CFL, 75 Watt LuxMagic                                 75    5250    E3   $12
Screw-In CFL, 85 Watt                                          85    4675    E3   $12
Screw-In CFL, 100 Watt                                         100   5100    E3   $12
Screw-In CFL, 105 Watt,                                        105   5865    E3   $12
Screw-In CFL, 125 Watt                                         125   6375    E3   $12
Screw-In CFL, 150 Watt                                                         150      7650         E3         $12
=================================
SIGNS and DOWNLIGHTS
=================================
New LED Exit Sign                                                                3        2          F1         $50
New LED Exit Sign with battery back-up                                           9        2          F1         $50
New LED Recessed Downlight or tracklight (LR6 or equivalent)                    12       650         F2         $30
New LED 16 Watt "DockLight"                                                     16       660         F2         $30
=================================
INDUCTION (New Fixture or Retrofit kit)
=================================
Induction, 40 Watt lamp                                                        41       3400         G1         $80
Induction, 55 Watt globe-shaped lamp                                           55       2800         G1         $80
Induction, 80 Watt lamp                                                        82       6800         G1         $80
Induction, 85 Watt globe-shaped lamp                                           85       4800         G1         $80
Induction, 100 Watt lamp                                                       102      8500         G2        $150
Induction, Icetron 100 Watt donut-shaped lamp                                  157      5920         G2        $150
Induction, 120 Watt Lamp                                                       122      10200        G2        $150
Induction, 165 Watt globe-shaped lamp                                          165      9600         G2        $150
Induction, 200 Watt Lamp                                                       204      17000        G2        $150
Induction, 300 Watt Lamp                                                       306      26010        G2        $150
Induction, 400 Watt Lamp                                                       408      34680        G2        $150
=================================
METAL HALIDE (PULSE-START or ELECTRONIC) (New Fixture)
=================================
Pulse-Start Metal Halide
----------------------------
Metal Halide Pulse Start, 200 Watt Lamp                                        232      16000         I1       $150
Metal Halide Pulse Start, 250 Watt Lamp                                        291      19000         I1       $150
Metal Halide Pulse Start, 300 Watt Lamp                                        342      24400         I1       $150
Metal Halide Pulse Start, 320 Watt Lamp                                        370      26400         I1       $150
Metal Halide Pulse Start, 350 Watt Lamp                                        400      29600         I1       $150
Metal Halide Pulse Start, 400 Watt Lamp                                        455      31500         I2       $200
Metal Halide Pulse Start, 450 Watt Lamp                                        514      40000         I2       $200
Metal Halide Pulse Start, 750 Watt Lamp                                        818      60000         I2       $200
Metal Halide Pulse Start, 875 Watt Lamp                                        940      80500         I2       $200
Metal Halide Pulse Start, 1000 Watt Lamp                                      1080      96000         I2       $200
----------------------------
Electronic Metal Halide
----------------------------
Metal Halide, 250 Watt Lamp, Electronic Ballast                                269      22865         I1       $150
Metal Halide, 320 Watt Lamp, Electronic Ballast                                344      29240         I1       $150
Metal Halide, 350 Watt Lamp, Electronic Ballast                                375      31875         I1       $150
Metal Halide, 400 Watt Lamp, Electronic Ballast                                425      36120         I2       $200
Metal Halide, 450 Watt Lamp, Electronic Ballast                                478      40630         I2       $200
=================================
OCCUPANCY SENSORS, TIMERS, PHOTOCELLS, and CONTROL PANELS
=================================
                                                                                                        J1       $35
Occupancy Sensor, Timer, Photocell, or Control Panel controlling the above fixtures (50 to 200 watts) (reduce proposed operating hours accordi
                                                                                                       J2        $60
Occupancy Sensor, Timer, Photocell, or Control Panel controlling the above fixtures (over 200 watts) (reduce proposed operating hours accordin
=================================
Non-Standard Measures (Requires BPA Approval)
=================================
Screw-in LED (1 Watt)                                                            1       60          M1      call BPA
Screw-in LED or cold cathode (3 Watt)                                            3       120         M1      call BPA
Screw-in LED (4 Watt)                                                            4       240         M1      call BPA
Screw-in LED or cold cathode (5 Watt)                                          5        200    M1   call BPA
Screw-in LED (6 Watt)                                                          6        360    M1   call BPA
Screw-in LED or cold cathode (8 Watt)                                          8        300    M1   call BPA
----------------------------
Screw-in Ceramic Metal Halide (self-ballasted)                                25       1220    M1   call BPA
----------------------------
                                                                                3
New LED refrigerator case light (3 watts per linear foot - input linear feet as quantity)195   M1   call BPA
                                                                                6
New LED refrigerator case light (6 watts per linear foot - input linear feet as quantity)390   M1   call BPA
                                                                                1
New LED channel letter lighting (1 watts per linear foot - input linear feet as quantity) 65   M1   call BPA
                                                                                2       130
New LED channel letter lighting (2 watts per linear foot - input linear feet as quantity)      M1   call BPA
----------------------------
New LED Outdoor Street/Area Light Fixture (28 Watt)                           28      1700     M1   call BPA
New LED Outdoor Street/Area Light Fixture (104 Watt)                          104     6800     M1   call BPA
New LED Outdoor Street/Area Light Fixture (207 Watt)                          207     13600    M1   call BPA
New LED Outdoor Street/Area Light Fixture (306 Watt)                          306     20400    M1   call BPA
----------------------------
Metal Halide, 50 Watt Lamp, Electronic Ballast                                56      4760     M1   call BPA
MH Pulse Start, 1-PS 50 Watt Lamp                                             68      2100     M1   call BPA
Metal Halide, 70 Watt Lamp, Electronic Ballast                                76      6460     M1   call BPA
MH Pulse Start, 1-PS 70 Watt Lamp                                             90      3400     M1   call BPA
Metal Halide, 100 Watt Lamp, Electronic Ballast                               108     9180     M1   call BPA
MH Pulse Start, 1-PS 100 Watt Lamp                                            125     5500     M1   call BPA
Metal Halide, 150 Watt Lamp, Electronic Ballast                               158     13430    M1   call BPA
MH Pulse Start, 1-PS 150 Watt Lamp                                            185     9500     M1   call BPA
MH Pulse Start, 1-PS 175 Watt Lamp                                            208     14000    M1   call BPA
----------------------------
High Pressure Sodium, 35W                                                     45      1845     M1   call BPA
High Pressure Sodium, 50W                                                     68      3280     M1   call BPA
High Pressure Sodium, 70W                                                     86      5166     M1   call BPA
High Pressure Sodium, 100W                                                    120     7790     M1   call BPA
High Pressure Sodium, 150W                                                    170     13120    M1   call BPA
High Pressure Sodium, 200W                                                    245     18040    M1   call BPA
High Pressure Sodium, 250W                                                    295     22550    M1   call BPA
High Pressure Sodium, 310W                                                    365     30340    M1   call BPA
High Pressure Sodium, 400W                                                    457     41000    M1   call BPA
----------------------------
MR-16 or MRC-16 Halogen Display Lamps, 20W                                    20        240    M1   call BPA
MR-16 or MRC-16 Halogen Display Lamps, 35W                                    35        490    M1   call BPA
MR-16 or MRC-16 Halogen Display Lamps, 40W                                    40        600    M1   call BPA
MR-16 or MRC-16 Halogen Display Lamps, 50W                                    50        790    M1   call BPA
MR-16 or MRC-16 Halogen Display Lamps, 75W                                    75       1320    M1   call BPA
=================================
ENTER OTHER NON-STANDARD MEASURES BELOW
=================================




=================================
Note: Download the most current list of high performance qualifying lamps from the CEE website at:
http://www.cee1.org/com/com-lt/lamps-ballasts.xls
The CEE homepage is available through the link below:
CEE—Consortium for Energy Efficiency
Note: Download the most current list of high performance qualifying ballasts from the CEE website at:
http://www.cee1.org/com/com-lt/lamps-ballasts.xls
The CEE homepage is available through the link below:
CEE—Consortium for Energy Efficiency
he CEE website at:

				
DOCUMENT INFO
Shared By:
Categories:
Stats:
views:3
posted:7/16/2011
language:English
pages:18
Description: Project for Credit Ratio document sample