PIPE FRICTION APPARATUS

Document Sample
PIPE FRICTION APPARATUS Powered By Docstoc
					SOLTEQ®                     Equipment for Engineering Education & Research




                      PIPE FRICTION APPARATUS
                                                                                      MODEL: FM 111




              HIS Pipe Friction Apparatus (Model: FM111) has been designed for students to measure pipe

T             friction losses for laminar and turbulent flows. For laminar flow study, an elevated head tank is
              used for water supply, whilst for turbulent flow, the supply is from the Hydraulics Bench (Model:
              FM 110) using hoses with rapid action hose coupling. Students may control the flow rate of water
by adjusting the flow regulator valve. The test section is connected to manometers via pressure tappings.



EXPERIMENTAL CAPABILITIES                                  SPECIFICATIONS

The unit allows students to perform the following          Manometers:
experiments:                                               Utube water manometer (0-550mm)
                                                           Utube mercury manometer (0-550mm)
♦ Measurement of pressure loss for laminar and
  turbulent flow                                           Water Storage:
                                                           Elevated cylindrical tank (Approximately 920 mm
♦ Determination of critical Reynolds’ number               constant head)
                                                           Tank capacity: 5 Liter (level indicator included)
♦ Head loss measurements using tube manometer              Maximum flow rate: 1.45 (nominal)
  and mercury U tube manometers
SOLTEQ®                   Equipment for Engineering Education & Research




                                                                     SOLTEQ
Test pipe :                                        MANUALS
Length (nominal) : 524 mm
Bore (nominal) : 3 mm                              The unit is supplied with Operating and Experiment
Needle valve included to regulate flowrate         Manuals in English giving full descriptions of the
                                                   unit, summary of theory, experimental procedures
                                                   and typical experimental results.

REQUIREMENTS

Hydraulic Bench (Model: FM110)
Electrical : 240VAC/1-phase/50Hz
Water       : Laboratory mains supply

OVERALL DIMENSION

Height      : 0.9 m
Width       : 0.6 m
Length      : 1.2 m
 SOLTEQ®                              Equipment for Engineering Education & Research
TYPICAL EXPERIMENT RESULTS




                                                                                             SOLTEQ
 i) Log h versus Log u

                                                 Log h Vs Log u (6 m m Pipe)


                          1.0


                          0.5


                          0.0                                                     y = 1.6848x
                  Log h




                          -0.5

                          -1.0


                          -1.5


                          -2.0
                              -0.8      -0.6   -0.4     -0.2      0.0       0.2        0.4      0.6   0.8
                                                                Log u




 ii) h versus u


                                                      h Vs u (6 m m Pipe)


                          6.0

                          5.0

                          4.0

                          3.0
                  h




                          2.0

                          1.0

                          0.0
                                0.0     0.5    1.0      1.5      2.0        2.5        3.0      3.5   4.0
                                                                  u
 SOLTEQ®                         Equipment for Engineering Education & Research


SOFTWARE & e - LEARNING


Our range of teaching equipment can be complemented with our
SOLDAS and SOLCAL software.



      SOLDAS® - Supervisory Control & Data Acquisition
      - Data Logging
      - Signal Analysis
      - Process Control
      - Real-Time Display
      - Tabulated Results
      - Graph of Experimental Results




      SOLCAL® - Computer Aided Learning
      - Multimedia Features
      - Interactive
      - Graphic Simulation
      - Experiment Result Samples
      - Full Experiment Manuals




Contact us for a catalog CD

SOLUTION ENGINEERING SDN. BHD.                           AGENT:
(Co. No. 174876-M)
Sales Office :
No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara,
47100 Puchong, Selangor Darul Ehsan, Malaysia.
Tel. No.: +(603) 80758000
Fax. No.        : +(603) 80755784
R&D Office :
G-2A, Incubator 3, Technology Park Malaysia,
Bukit Jalil, 57000 Kuala Lumpur, Malaysia.
Tel. No. : +(603) 8996 0023

Email    : solution@solution.com.my                                         MSC- Status
                                                          BUATAN MALAYSIA    Company
Web site : http//www.solution.com.my/

				
DOCUMENT INFO