                QA Test Report
                                   TPC-650

                                 ( Safety Test )
                                 Report No    : 03P001A0

                                 Report Date : February 25, 2003




                _______________________      ____________________   _____________________
                 Chi-Horng Liao                Charles Chang             Lily Huang
  Issue Stamp
                Manager of QA Department            Approval            Test Engineer
TPC-650                            Hi-Pot test                    Report No.:03P001A0
QA Lab Safety test

Test Date    : February 25, 2003
Test Site    : Advantech QA safety Lab
Performed By : Lily Huang


Test propose : Manufactures approval test


Test Standard :
                     Reference UL60 950, third edition, which includes the Second Amendment
                     of IEC60 950, CAN/CSA C22.2 No. 950.
                      Safety analyze instrument Test


Test Condition :
                     1. Primary to ground ¡G 2121 Vdc
                     2. Primary to secondary¡G 4242 K Vdc
                     3. Test time¡G 1 minute


Test Equipment :
                       Safety test system
                       Extech Electronics Co., Ltd.
                       Model ¡G CRW-100
                       Day of Calibration : 04-12-2002


Sample Configuration & Quantity Under Test:

                 Using one TPC-650 industry computer with SNP-PA59 adaptor.
TPC-650                     Hi-Pot test                        Report No.:03P001A0
QA Lab Safety test



Performance Criteria:

      Electronic function check:
                1. The power supply DC output voltage meets specification.
                2. The power supplies electronic function without degradation of the
                   performance.


      Mechanical function check:
              1. The connectors can work properly without any interference.
              2. All screws are tightening up appropriately.
              3. All gaps on the surface are appropriately.
              4. The enclosure or mechanical parts must be no deformed parts.


Test Data:
                     The test value ¡G 0 mA


Test Result:

                There was no insulation breakdown during the test.


Conclusion :

                Passed.
                The TPC-650 industry computer meets the Hi-pot test.


                .
TPC-650                        Insulation Res. test             Report No.:03P001A0
QA Lab Safety test

Test Date    : December 2, 2002
Test Site    : Advantech QA safety Lab
Performed By : Lily Huang


Test proposes: Manufactures approval test


Test Standard: Reference EN60 950 test standard


Test Condition:
                     1. Test voltage range¡G DC 500 Vdc
                     2. Resistance¡G upward 10 MΩ

Test Equipment:
                       Safety test system
                       Extech Electronics Co., Ltd.
                       Model ¡G CRW-100
                       Day of Calibration : 04-12-2002


Sample Configuration & Quantity Under Test:

                 Using one TPC-650 industry computer with SNP-PA59 adaptor
TPC-650                 Insulation Res. test                   Report No.:03P001A0
QA Lab Safety test




Performance Criteria:
    Electronic function check:
              1. The power supply DC output voltage meets specification.
              2. The power supplies electronic function without degradation of the
                 performance.

      Mechanical function check:

                     1. The connectors can work properly without any interference.
                     2. All screws are tightening up appropriately.
                     3. All gaps on the surface are appropriately.
                     4. The enclosure or mechanical parts must be no deformed parts.


Test Data:
                         The test value¡G Primary to ground ¡G 7.13 GΩ
                                            Primary to secondary¡G > 9.9 GΩ



Test Result:
                        Test is no electronic function damage or degradation has found, and
                     without any incurably physical damage degradation the performance.
                .

Conclusion:
                Passed.
                    The TPC-650 meets Insulation Res. test.

								