					                                               Instructions for Updating The Master File Database (MFD) Values Via the
                                             California Independent System Operator (CISO) Resource Data Template (RDT)

    1) Complete the appropriate data fields, or update the existing data values in this file with your new values.
    2) Notate the previous value(s) using the MS Excel function 'Insert Comment' for the updated values.
    3) If there is a need to insert more segments, please insert them with the associated RES_ID and highlight them in yellow.
    4) Highlight the cells in yellow for the modified and new data. The uncolored cells will not be updated.
    5) Highlight the cells in green if you have questions about the data.
    6) Use the COMMENTS column on each tab to explain the nature of the change in data.
    7) Reference the Definition and Code sheets for more information.
    8) The CISO will coordinate with the Schedule Coordinator (SC) and Participate Generator Owner (PG) before making the changes to the Master File Database.


Initiate Processing of Your RDT Changes to the CISO Master File Database
Send the updated file with your comments to your CISO Client Representative, or directly to the ResourceData@caiso.com Mailbox for processing.


Notes Regarding Changes, and Dependent Data
 1. Updates to the Resources Tab:
   A) Updates to PMax/PMin/MDL data:
        a. Heat Rate Tab Dependency: The associated heat rate must be provided at the new PMax/PMin output level
        b. Ramp Rate Tab Dependency: The associated ramp rate point must be provided at the new PMax/PMin output level.
        c. PMax >= MDL >= PMin
   B) Updates to Maximum Ramp Rate data:
        a. Ramp Rate Tab Dependency: The highest MAX_RAMP_RATE value on the Ramp Rate tab must be equal to the MAX_RAMP_RATE value on the Resources tab.
 2. Updates to Ramp Rate Tab: Not more than 11 segments per RES_ID
 3. Updates to Heat Rate Tab: No Heat Rate values within a Forbidden Region. Not more than 11 segments per RES_ID.
 4. Updates to Startup Tab: Down Time must be 0 on segment 1. Not more than 11 segments per RES_ID.
 5. Updates to the Forbidden Region Tab:
        a. Not more than 4 segments.
        b. Heat Rate Tab Dependency: Must provide the values of upper/lower boundary of the Forbidden Region.
 6. For dynamic resource, only the MFD_Resources, MFD_RampRate, and MFD_Startup tabs are required.
 7. For non-dispatchable resources including BGAS, WIND, and SOLR, only the MFD_Resources tab is required.
 8. For RMR resources, contact the CISO RMR Contracts Department before making Ramp Rate data changes.
 9. The UDC_ID, ZONE_ID, DMND_ZONE, LOAD_GRP and CERT_CD are CISO provided values.
                                                        SRDT Data Request Definitions




                                                       Resources Definitions
             Column Name                 Column Code                         Unit                             Definition
Resource Identifier                        RES_ID                                       The unique CISO resource identifier used for tracking
                                                                                        each resource for market scheduling and outage
                                                                             text       coordination purposes.
Resource Name                            RES_NAME                            text       Descriptive name for the Resource.
Participating Generator Agreement Name   PGA_NAME                                       The contractual name as noted on the Participating
                                                                                        Generator Agreement (PGA) between the resource
                                                                             text       owner and the CISO.
Scheduling Coordinator Identifier          SC_ID                                        The four digit identifier of the entity authorized to
                                                                                        submit to the CISO a generation or demand schedule
                                                                                        on behalf of one or more generators, and one or
                                                                             text       more end-users customers.
Resource Type                            RES_TYPE                                       Descriptive identifier denoting the type of resource:
                                                                             text       Generating Unit, Synchronous Condenser.
Prime Mover Technology                   GEN_TECH                                       Description of prime mover technology associated
                                                                                        with the Generating Unit; such as, Hydro Turbine,
                                                                             text       Gas Turbine, Combined Cycle, etc.
Primary Fuel Type                        FUEL_TYPE                                      Description of primary fuel type; such as, Natural
                                                                             text       Gas, Oil, Nuclear, etc.
Air Quality Management District           AQM_DIST                                      The Air Quality Management District or Air Pollution
                                                                             text       Control District in which the resource is located.
Certification Code                        CERT_CD                                       The identifier used to denote which Ancillary Service
                                                                                        certification(s) a resource holds. S = Spin, N = Non-
                                                                             text       Spin, R = Regulation, P = Replacement.
Maximum Emergency Capability                MEC                                         The maximum potential power output capability
                                                                                        (MEC) of a Generating Unit for short-time emergency
                                                                                        operating conditions. Its value should be > or = PMAX.
                                                                             MW
Normal Maximum Capacity (PMAX)              PMAX                                        The maximum Net Dependable Capacity (PMAX or
                                                                                        PMAX) a Generating Unit can produce on a sustained
                                                                                        basis as measured at or compensated to the
                                                                                        Generating Unit's defined point of delivery. It is
                                                                                        mathematically equal to a Generating Unit's Gross
                                                                             MW         Dependable Capac




                                                                   Page 2
                                                         SRDT Data Request Definitions



Minimum Dispatchable Level                    MDL                                        The minimum operating level at which a Generating
                                                                                         Unit is able to readily respond to a CISO dispatch
                                                                                         instruction (MDL). It should be a forbiden range
                                                                              MW         between MDL and Pmin.
Minimum Operating Level                       PMIN                                       The minimum output level (PMIN) at which a
                                                                              MW         Generating Unit can operate on a sustained basis.
Single Maximum Ramp Rate                 MAX_RAMP_RATE                                   The single maximum ramp rate for Ancillary Service
                                                                          MW/minutes     and current BEEP.
Minimum On Time                           MIN_ON_TIME                                    The minimum amount of time that a Generating Unit
                                                                                         must stay on-line after being started up, prior to
                                                                                         being shut down, due to physical operating
                                                                             Minutes     constraints.
Maximum Daily On Time                     MAX_ON_TIME                                    The maximum amount of time that a Generating Unit
                                                                                         can stay on-line per day when operating at its PMAX
                                                                                         level, if constrained by environmental or physical
                                                                             Minutes     operating constraints.
Minimum Off Time                          MIN_OFF_TIME                                   The minimum amount of time that a Generating Unit
                                                                                         must stay off-line after being shut down, due to
                                                                             Minutes     physical operating constraints.
Maximum Shutdown Time                  MAX_SHUTDOWN_TIME                                 The maximum amount of time (in minutes) required
                                                                                         for a Generating Unit to disconnect from the grid
                                                                                         after reaching its PMin specified in the Master File
                                                                             Minutes
Maximum Daily Startups                 MAX_DAILY_STARTUPS                                The maximum number of times a Generating Unit can
                                                                                         be started up within one day, due to environmental
                                                                             Integer     or physical operating constraints.
Minimum Regulation Capacity Region 1     MIN_REG_CAP1                                    The lower limit of the Generating Unit's first
                                                                              MW         regulation capability range.
Maximum Regulation Capacity Region 1     MAX_REG_CAP1                                    The upper limit of the Generating Unit's first
                                                                              MW         regulation capability range.
Minimum Regulation Capacity Region 2     MIN_REG_CAP2                                    The lower limit of the Generating Unit's second
                                                                              MW         regulation capability range.
Maximum Regulation Capacity Region 2     MAX_REG_CAP2                                    The upper limit of the Generating Unit's second
                                                                              MW         regulation capability range.
Maximum Reactive Power Absorption          MAX_GEN_Q
Capability                                                                               The maximum reactive power absorption capability
                                                                             MVAR        at the Generating Unit's defined point of delivery.




                                                                    Page 3
                                                  SRDT Data Request Definitions



Maximum Reactive Power Output       MIN_GEN_Q                                     The maximum reactive power output capability at
Capability                                                            MVAR        the Generating Unit's defined point of delivery.
Minimum Operating Voltage Level    MIN_GEN_KV                                     The minimum operating voltage level in kV at the
                                                                        KV        terminals of the Generating Unit.
Maximum Operating Voltage Level    MAX_GEN_KV                                     The maximum operating voltage level in kV at the
                                                                        KV        terminals of the Generating Unit.


                                                Ramp Rate Definitions
Ramp Rate Point Number               SEG_NO                                       Point numbers between the PMIN and PMAX of the
                                                                                  Generating Unit output. The point numbering starts
                                                                      Integer     at 1.
Output of Point Range (MW)             MW                                         The Generating Unit MW output of point i. The first
                                                                                  point (1) of MW output must begin at the Generating
                                                                                  Unit's PMIN. The last point (n) of MW output must end
                                                                       MW         at the Generating Unit's PMAX.
Minimum Ramp Rate                 MIN_RAMP_RATE                                   The minimum ramp rate of the Generating Unit
                                                                                  between point (i) and the point (i+1). The minimum
                                                                                  ramp rate of the last point should = the previous one.
                                                                                  This requires providing the minimum ramp rate of the
                                                                                  first point (1) at PMIN and last point (n) at PMAX.
                                                                   MW/minutes
Maximum Ramp Rate                 MAX_RAMP_RATE                                   The maximum ramp rate of the Generating Unit
                                                                                  between point (i) and the point (i+1). The maximum
                                                                                  ramp rate of the last point should = the previous one.
                                                                                  This requires providing the maximum ramp rate of
                                                                                  the first point (1) at PMIN and last point (n) at PMAX.


                                                                   MW/minutes


                                                Heat Rate Definitions
Heat Rate Point Number               SEG_NO                                       The point numbers between the PMIN and PMAX of
                                                                                  the Generating Unit output.
                                                                                  The point starts at 1.
                                                                                  Note: The heat rate, emission rate, and average cost
                                                                                  must include the data at the bottom and top of each
                                                                                  forbidden region and exclude the data within the
                                                                      Integer     Forbidden Region.



                                                             Page 4
                                             SRDT Data Request Definitions



Output at Point Range (MW)        MW                                           The Generating Unit output of point 1. The first point
                                                                               (1) of MW output must start at the Generating Unit's
                                                                               PMIN. The last point (n) of MW output must end at
                                                                    MW         the Generating Unit's PMAX.
Average Heat Rate             HEAT_RATE
                                                                               The average heat rate of the Generating Unit on
                                                                               point (i). Use linear interpolation approach to obtain
                                                                               the heat rate value between point (i) and point (i +
                                                                               1). This requires providing the heat rate of the first
                                                                 BTU/KWh       The emission rate of last point (n) at PMAX.
                                                                               point (1) at PMIN andthe Generating Unit on point (i).
Emission Rate                EMISSION_RATE                  lbs of NOx/MWh     Use linear interpolation approach to obtain the
Average Operating Cost         AVG_COST
                                                                               The average operating cost ($/MWh) applies to non
                                                                               natural gas-fired Generating Units. This requires
                                                                               providing the Average Operating Cost of the first
                                                                  $/MWh        point (1) at PMIN and the last point (n) at PMAX.


                                            Start Up Definitions
Startup Segment Number          SEG_NO
                                                                               The segment numbers between the PMIN and PMAX of
                                                                  Integer      the Generating Unit output. The segment starts at 1.
Generator Down Time           DOWN_TIME                                        The amount of time the Generating Unit must be off
                                                                               (in minutes) within sequence (i). The first down time
                                                                  Minutes      must be zero.
Generator Startup Time       STARTUP_TIME                                      Startup Time is the time (in minutes) it takes a
                                                                               resource to achieve PMin from an off-line position
                                                                               given the corresponding Down Time. The startup time
                                                                               of the Generating Unit from the down time (i) to
                                                                               down time (i + 1). The last sequence is the startup
                                                                  Minutes      time from the current sequence to infinite.
Startup Cost                 STARTUP_COST                                      The startup cost of non-natural gas fired Generating
                                                                               Units (in dollars) from the down time (i) to down time
                                                                               (i + 1). The last sequence is the startup cost (in
                                                                 Dollars ($)   dollars) from current sequence to infinite.




                                                        Page 5
                                                                  SRDT Data Request Definitions



Startup Fuel Use                               STARTUP_FUEL                                           The fuel use (in mBTU per start) expected for the
                                                                                                      startup of a natural gas fired Generating Unit that
                                                                                                      has been off-line for a substantial period of time. The
                                                                                                      startup fuel of the Generating Unit (in mBTU) from
                                                                                                      the down time (i) to down time (i + 1). The last
                                                                                                      sequence is the startup fuel (in mBTU) from current
                                                                                        Million BTU   sequence to infinite.
Startup Auxiliary Energy Requirement           STARTUP_AUX                                            The electrical power used by a Generating Unit
                                                                                                      during startup. The Generating Unit's startup
                                                                                                      auxiliary power (in MWh) from the down time (i) to
                                                                                                      down time (i + 1). The last sequence is the startup
                                                                                                      auxiliary power (in MWh) from current sequence to
                                                                                          MWh         infinite.


                                                         Forbidden Region Definitions
Forbidden Region Segment Number                    SEG_NO                                             The segment numbers between the PMIN and PMAX of
                                                                                                      the Generating Unit output, with the segment
                                                                                                      starting at 1.
                                                                                                      The heat rate, emission rate, and average cost must
                                                                                                      include the data at the bottom and top of each
                                                                                                      forbidden region and exclude the data within
                                                                                          Integer     forbidden regions.
Lower Range                                      LOWER_MW                                             The lower MW output of the Forbidden Region of the
                                                                                                      current segment. The Forbidden Region should be
                                                                                                      inside of segment (i); meaning a Forbidden Region
                                                                                                      cannot cross two segments and the segment cannot
                                                                                           MW         be overlapped.
Upper Range                                      UPPER_MW                                             The higher MW output of the Forbidden Region of the
                                                                                                      current segment. The Forbidden Region should be
                                                                                                      inside of segment (i); meaning a Forbidden Region
                                                                                                      cannot cross two segments and the segment cannot
                                                                                           MW         be overlapped.




                   A Sample of A Generator Operating Range Model (a 160 MW unit)


                                                                               Page 6
       (MEC) Maximum Emergency                      Non-Market Range              160 MW
       Capability                              (Out-of-Market Dispatch Only)
                                                                                  155 MW
                                                         SRDT Data Request Definitions

       A Sample of A Generator Operating Range Model (a 160 MW unit)



(MEC) Maximum Emergency                 Non-Market Range                   160 MW
Capability                         (Out-of-Market Dispatch Only)
                                                                           155 MW
(PMAX) Maximum Normal
                                 Segment n: Max/Min RR, HR, ER
Capability

                                                                           95 MW
                                                                           85 MW
Dispatchable Range
                                                                           50 MW
Forbidden Range
                                 Segment 1: Max/Min RR, HR, ER             40 MW

(MDL) Min Dispatchable Level           Non-Dispatchable Range
                                                                           30 MW
                                 Between PMIN and MDL:
                                  Operation feasible only for fixed
                                    dispatches and transition
(PMIN) Normal Min Gen             Single Max/Min Ramp Rate only
                                                                           20 MW
                                      Non-Dispatchable Range

                                      (Operation feasible only for
                                   transition between 0 and PMIN
                                   during start-up and shut-down)


                                                                           0 MW




                                                                        Page 7
                                        SDRT Data Request Options




            Resource Type (Code)                             Air Quality Management District
   Code                   Name                       Code                       Name
   GENR              Generating Unit                  SISK   Siskiyou
   SYNC           Synchronous Condenser              MODO    Modoc
                                                     NCUN    North Coast Unified
           Prime Mover Technology                    SHAS    Shasta
  Code                     Name                      LASS    Lassen
 HYDR        Hydro Turbine                           TEHA    Tehama
 PTUR        Hydro Pump-Turbine                      MEND    Mendocino
 GTUR        Gas Turbine                             GLEN    Glenn
 STUR        Steam Turbine                           BUTT    Butte
 CCYC        Combined Cycle                          NSER    Northern Sierra
 RECP        Reciprocating Engine                    FRVR    Feather River
 PHOT        Photovoltaic                            COLU    Colusa
 WIND        Wind Turbine                            LAKE    Lake
 SYNC        Synchronous Condenser                   NSON    Northern Sonoma
 OTHR        Other*                                  YOSO    Yolo/Solano
                                                     PLAC    Placer
              Primary Fuel Type                      ELDO    El Dorado
   Code                  Name                        SACM    Sacramento Metro
 GAS         Natural Gas                             AMAD    Amador
 COAL        Coal/Coke                               SFBA    San Francisco Bay Area
 HRCV        Heat Recovery                           SJVU    San Joaquin Valley Unified
 OIL         Oil                                     CALA    Calaveras
 NUCL        Nuclear                                 TUOL    Tuolumne
 WAST        Waste to Energy                         MARI    Mariposa
 BIOM        Biomass                                 GBUN    Great Basin Unified
 GEOT        Geothermal                              MBUN    Monterey Bay Unified
 WIND        Wind                                    SLUO    San Luis Obispo
 SOLR        Solar                                   SBRB    Santa Barbara
 WATR        Water                                   VENT    Ventura
 BGAS        Bio Gas
             (Landfill, Sewage Digester, etc.)       KERN    Kern
 OTHR        Other*                                  MOJD    Mojave Desert
                                                     ANTV    Antelope Valley
* If Other is chosen, provide an explanation.        SCOA    South Coast
                                                     SDIE    San Diego
                                                     IMPE    Imperial
                                                     OTHR    Other Region*




                                                 Page 8
SDRT Data Request Options




         Page 9
                                MFD_Resources


RES_ID RES_NAME PGA_NAME SC_ID UDC_ID ZONE_ID DMND_ZONE LOAD_GRP RES_TYPE




                                   Page 10
                                MFD_Resources


GEN_TECH FUEL_TYPE AQM_DIST CERT_CD MEC PMAX MDL PMIN MAX_RAMP_RATE




                                   Page 11
                                MFD_Resources


MIN_ON_TIME MAX_ON_TIME MIN_OFF_TIME MAX_SHUTDOWN_TIME MAX_DAILY_STARTUPS




                                   Page 12
                               MFD_Resources


MIN_REG_CAP1 MAX_REG_CAP1 MIN_REG_CAP2 MAX_REG_CAP2 MAX_GEN_Q MIN_GEN_Q




                                  Page 13
                                 MFD_Resources


MAX_GEN_KV MIN_GEN_KV QUERIED DATE EFFECTIVE TRADE DATE   COMMENTS




                                    Page 14
                               MFD_RampRate


RES_ID SEG_NO MW MAX_RAMP_RATE MIN_RAMP_RATE QUERIED DATE




                                  Page 15
                                  MFD_RampRate


EFFECTIVE TRADE DATE   COMMENTS




                                     Page 16
                                 MFD_HeatRate


RES_ID SEG_NO MW HEAT_RATE EMISSION_RATE AVG_COST QUERIED DATE




                                   Page 17
                                  MFD_HeatRate


EFFECTIVE TRADE DATE   COMMENTS




                                    Page 18
                                 MFD_StartUp


RES_ID SEG_NO DOWN_TIME STARTUP_TIME STARTUP_COST STARTUP_FUEL STARTUP_AUX




                                   Page 19
                                    MFD_StartUp


QUERIED DATE EFFECTIVE TRADE DATE   COMMENTS




                                      Page 20
                              MFD_ForbiddenRange


RES_ID SEG_NO LOWER_MW UPPER_MW QUERIED DATE EFFECTIVE TRADE DATE   COMMENTS