Air curtains and fan heaters

Document Sample
Air curtains and fan heaters Powered By Docstoc
					  Air curtains and fan
               heaters




www.systemair.ru
2
                                                                                            Contents


                                                        Contents



About the group of companies                                                                                               4-5
...........................................................................
                                                                                                                           6-7
Manufacture of air curtains and fan heaters ...........................................
                                                                                                                           8-9
Research and development ...............................................................
                                                                                             10-17
Selecting the right air curtain ...............................................................

Air curtains                                                                                                                20-22
         AS Series ........................................................................................................ 18-30
         LG Series ........................................................................................................ 34-37
         Portier Mini Series ........................................................................................... 38-43
         Portier Basic Series ......................................................................................... 44-49
         Portier Basic Design Series .............................................................................50-59
         Portier Grand Series ....................................................................................... 60-69
         Portier Grand Design Series ........................................................................... 72-79
         HD Series ........................................................................................................ 80-91
         HF Series ........................New!.................................................................            92-95
         MTV Series ......................................................................................................

Fan heaters                                                                                                              98-99
        Proff Series ..................................................................................................100-107
        FHW Series ..................................................................................................108-110
        FHC Series....................New!..............................................................
                                                                                                                       112-113
Regulation of air curtains and fan heaters ....................................
                                                                                                                       111-120
Accessories ........................................................................




                                                                                                                               3
     About the group of companies




The best exporter of Sweden award in 2007 was held neither by
manufacturers of automobiles, nor furniture and most certainly not
by producers of alcoholic beverages.
Systemair is the world’s number one manufacturer of venti-    Swedish Trade Council. The award was presented by His
lation equipment. Our products help improve the air quality   Majesty Carl XVI Gustaf, King of Sweden.
in homes, schools, shopping centers, offices and enterpris-
es all over the world.                                        Systemair is one of the few companies in the world that has
                                                              proudly maintained a triple “A” credit rating over a period of
Today Systemair is the Parent Corporation of an interna-      13 years.
tional group of companies, comprised of over 50 subsidiary    In October 2007 Systemair was listed on the Stock
companies.                                                    Exchange, which serves as additional evidence of the
Main production facilities, with a total area exceeding 130   Company’s stability and credibility.
thousand square meters, are located in nine countries:
Sweden, Denmark, Norway, Germany, Slovenia, Lithuania,        Russia and the CIS (Commonwealth of Independent States)
Slovakia, Spain and Canada.                                   are a major market for Systemair and thereby contribute
                                                              to a strong average sales growth, which for the last 10
Company’s products are marketed under brand names of          years has been around 20% per annum.
Systemair, VEAB, Frico and Fantech.                           We are very proud of our successes. But they would be
                                                              impossible without the help of our fellow partners: design-
                                                              ers, assemblers and distributors. And for this we would like
                                                              to say THANK YOU!

In 2007 Systemair was acknowledged as the best exporter
of the year and awarded the Major Export Award by the




4
                                                                About the group of companies



Main production facility, Skinnskatteberg, Sweden

Total area: 95,000 sq.m
Area of production facility: 50,000 sq.m
Number of employees: 400
This is the location of the Group’s head office, as well as the largest production
facility and a state-of-the-art laboratory. The major part of the output is made
up of duct fans, air curtains and air handling units.




        “Klockargarden”, Skinnskatteberg, Sweden

        Total area: 300,000 sq.m
        Area of production facility: 20,000 sq.m
        Number of employees: 50
        This is where the showroom and additional office spaces are
        located. It is also a manufacturing facility of small ventilation
        units and packaged units.




       Aarhus, Denmark

       Total area: 25,000 sq.m
       Area of production facility: 16,800 sq.m
       Number of employees: 100
       This is where Systemair’s largest units are manufactured - DV,
       with air flow up to 86,000 m.3/h.




        Windischbuch, Germany

        Total area: 40,878 sq.m
        Area of production facility: 15,882 sq.m
        Number of employees: 170
        This is where most of the roof and axial fans are assembled.
        Furthermore, it is the location of Systemair’s second largest
        warehouse in Europe.




                                                                                               5
     Production




                                                   Systemair production
                                                  Systemair has considerable experience in the produc-
                                                  tion of warm air curtains. All curtains are developed and
                                                  designed by our own highly skilled engineers at
                                                  Systemair’s factory in Skinnskatteberg, Sweden.
                                                  The factory is certified in accordance with the quality
                                                  assurance system ISO 9001 since 1993, and ISO 14001
                                                  since 1996. All air curtains have CE, SEMKO and NEMKO
The level of production automation is             certification marks and have been certified in Russia and
among the highest in Europe.                      Ukraine.

                                                  Air curtains are manufactured on highly automated pro-
                                                  duction lines. It is safe to say that our factory automation
                                                  level is one of the highest in Europe.
                                                  All metal parts of equipment are manufactured at Finn
                                                  Power’s metal processing line.

                                                  Only high quality accessories are used during the pro-
                                                  duction process.
                                                  All air curtains are equipped with two thermostats, protect-
                                                  ing the fan motor from overheating, and electric air-heat-
                                                  ing elements (in models with electric heating).
                                                  All models (excluding PM) are equipped with outer rotor
                                                  motors from EBM or Ziehl-Abegg, the world’s leading
                                                  manufacturers of this type of motors.
All metal parts are manufactured at Finn          All air curtains have a corrosion-proof casting from sheet
Power’s metal processing line.                    steel, galvanized in hot-dip procedure and coated with
                                                  white powder paint (RAL9016).

                                                  Each air curtain is thoroughly tested before its release
                                                  from the assembly line.




By virtue of fully automated machinery, high
quality grids for air curtains are produced.




 All heavy operations or work that is hazardous
 to human health are performed by machines.
 Automated paint shop.

6
                                                                                            Production


                                                            All our products are carefully packed in cus-
                                                            tom boxes on the assembly line.
Systemair production

At present Systemair has a wide assortment of air curtain
models, the design and technical features of which can
satisfy even the most demanding customer.

We are proud of our products! The company’s target is
to fine-tune both mass production and production in
small volumes in accordance with market needs.
This has determined the choice of equipment to be man-
ufactured and production planning.

The company is continuously improving product quality
and line management. Working conditions are also con-
stantly improved. The company’s production facilities are
clean and spacious. And as for office spaces, they are
designed in such a way that there are no square cor-
ners, which, according to scientific research, promotes a
wholesome psychological environment and creative
thinking.

All heavy operations or work that is hazardous to human
health are performed by machines. Often, the level
automation of production processes simply astounds. For
example, packing and transportation of goods within the
factory premises are performed by programmed
machines without human presence.                               Packed air curtains and fan heaters are
The factory provides safe and effective conditions for         always available in the warehouse
working personnel.

Systemair cares about the environment. All production
waste undergoes compulsory recovery and recycling. As
result of measures taken in environment protection, our
waste volume has been reduced by 90%.




                                                            and ready for transportation.




                                                            As result of measures taken in environment
                                                            protection, our waste volume has been
                                                            reduced by 90%. Equipment for recycling
                                                            packaging waste.

                                                                                                            7
       Research and development




                                                  Systemair’s center of scientific
                                                  research

                                                  Our center for scientific research and design is one of
                                                  the leading examples of its kind in Europe and is
                                                  equipped with the latest facilities for measurement of
                                                  aerodynamic, acoustic, thermal and other parameters
                                                  of manufactured equipment.

                                                  Research and measurements are regularly performed
                                                  both for development and experimental testing of new
                                                  models and for improving the operating characteristics
                                                  of existing products.

                                                  All measurements are conducted in accordance with
                                                  the requirements of the most widespread standards of
                                                  AMCA and ISO.

                                                  Acoustic tests and measurements
                                                  Our research and development center is equipped
                                                  with a reverberation chamber with a sound level less
                                                  than 10 dB(A). It is actually a complex consisting of
                                                  two chambers. The inner chamber, used for measur-
                                                  ing the sound level, is 33 tons in weight and is mount-
                                                  ed on 76 solid steel springs. This design facilitates its
    The Systemair lab is equipped with a unique   isolation from external impacts. It contains no parallel
    reverberation chamber.                        surfaces. Reverberation time is 6 seconds.

                                                  Air consumption measurement
                                                  Air consumption measurement the air curtain is con-
                                                  nected to the measuring stand and blows air into the
                                                  chamber with “zero” pressure. An exhaust fan is
                                                  placed on the other side to compensate for the loss of
                                                  pressure along the tract.
                                                  The air consumption is calculated by measuring the
                                                  pressure differential on the throttle plate. The latter is
                                                  calibrated in accordance with the AMCA Standard.
                                                  Each pressure differential has its own corresponding
                                                  air consumption.

                                                  Environmental test chamber
                                                  The Systemair lab is equipped with a special environ-
                                                  mental test chamber, which allows climate modeling
                                                  inside the premises and outside it. It is possible to
                                                  conduct production tests even if the outside tempera-
                                                  ture drops below
                                                  -20°C.




8
                                                               Research and development




Systemair’s center of scientific
research

The diffuser testing chamber
Air distribution systems are tested in an entirely dark
room, 54 m2 in area.. A laser is used to visualize air
currents. All measurements are conducted in accor-
dance with EN12238:2001 Standards.                          Due to the constant research and considerable
                                                            investment in product development, Systemair is not
Electrical safety test stand                                only able to create new models, but improves the
There is a special measurement stand for measuring          existing models as well.
the temperature and electric safety of fan motors and
thermal equipment, as well as motor coil temperature
in working conditions. All measurements are conduct-
ed in accordance with EN 60335-1 Standards.

Each air curtain and fan heater manufactured at the
Systemair factory must pass through a thorough test-
ing procedure before it can be released from the
assembly line.
This minimizes rejects, if not eliminating them altogeth-
er.

It should be noted that 60% of our design engineers
are women. Style and quality combined with safety is
our ultimate goal.                                          Each air curtain is thoroughly tested
                                                            before it reaches the customer.
You can always count on the quality and reliability of
Systemair products!




                                                            60% of Systemair design engineers are
                                                            women.




                                                                                                              9
      General overview of air curtains


What is an air curtain?
The purpose of an air curtain is to separate zones with dif-
ferent temperatures on either sides of open windows, entry
doorways and gates. By means of a high-speed airflow, an
“invisible barrier” is created, preventing warm air from
escaping and stopping cold air from entering the premises.
Thus the inner comfort of the premises is enhanced,
drafts disappear, heat losses are significantly lowered and,
as a result, so are heating costs.                                                         +                       =
The amount of heat loss through an open door depends
on:
- the difference in atmospheric pressure inside and outside
the building;
- the difference in temperature inside and outside the
building;                                                                      a)                        b)                 c)
- the wind velocity, relative to the doorway.

                                                                         Figure 1. Air flow through an open door




It is very important to carefully balance the ventilation sys-           When the wind blows directly at the door, the outside air
tems placed inside a building, so that the air flowing out of            flows into the building through the entire area of the door-
the building equals the air flowing in. This would allow a               way, as shown on Fig. 1a. The total airflow is made up from
decrease in the pressure difference in the doorway.                      all air currents flowing in and out, as shown on Fig. 1c. A
The hot air in the building is lighter than the cold air out-            correctly placed air curtain minimizes total airflow.
side. Thus, when the door opens, a pressure differential is
created, Fig. 1b.
Cold air flows into the building through the lower part of the
doorway and forces out light warm air from the building,
though the upper part of the doorway. An increase in the
temperature differential raises the volume of total airflow.




     winter cold


 summer heat       warm / cool air in
                   premises

     insects


  dirt / dust


  unpleasant
       odors




Figure 2.a). The separation             Figure 2.b). The zoning func-      Figure 2.c). Air curtains with     Figure 2.d). Helps circu-
function. Divides climate               tion is excellently suited for     heating elements dry the floor     late the air in large premis-
zones, eliminates drafts and            separation of conditioned and      and the surrounding area, as       es. Perfect for halls and
blocks heat coming from the             non-conditioned, smoking and       well as providing an additional
outside. No more insects, dirt,         non-smoking zones.                 source of warmth. A perfect        lobbies.
dust and unpleasant odors.                                                 solution for restaurants, shops
                                                                           and malls.




10
                                                                General overview of air curtains


Energy saving and comfort                                        returns back to the premises, while not blowing any of the
Open doors lead to significant loss of warmth. A properly        outside air in. This is why the air flow must be directed at
installed air curtain can lower the heat loss of premises by     an angle of 10 - 15° in the direction of the outer premises
90%. Air curtains prevent drafts from forming at the premis-     or the street.
es and allow shops to keep their doors open even in win-
tertime, thus making it more appealing to customers. In the      Proper placement of the air curtain, as well as the correct
summer time air curtains can work with the heating ele-          selection of speed, optimal direction and required tempera-
ments switched off, preventing warm air from reaching air-       ture of the airflow is crucial for its effective operation.
conditioned premises.
                                                                 Systemair offers a wide range of air-curtain control mecha-
Systemair offers a wide range of air curtains without heat-      nisms, designed with customer requirements in mind: from
ing elements, perfectly suited for such tasks. Such air cur-     inexpensive and simple solutions, such as by means of a
tains are well suited for refrigerated rooms, the air-chilled    control panel and thermostat, to complex programmable
section of supermarkets and greenhouses.                         control modules, door position sensors and temperature
The air curtains must be installed outside refrigerated          sensors, which are often used in facilities with a 24-hour
rooms, in the warm zone adjacent to them, at an angle of         operating schedule.
15°. Such placement prevents cold air from being blown
out into warm premises as drafts.



It should be noted that, no matter which kind of air curtain
you choose (with or without heating elements), the air flow
must be directed in a manner ensuring that its major part




       Figure 3. In order to prevent cold drafts from forming
       near the floor, 30% of the total airflow must be directed to
       the outside. To find the air parting boundary, a handker-
       chief should be held under the operating air curtain,
       30cm from the floor, and moved slowly in a crosswise
       direction. The airflow separation plane must fall in the
       middle of doorway or slightly outside of it. The velocity of
       the air flow near the floor must reach about 2 m/s.




How does the air curtain work?                                   a way as to send approximately 30% of the airflow outside.
All air curtains are equipped with a fan which directs an        This partition of the air current is needed to prevent cold
intense air current across the doorway. The kinetic energy       draughts from forming near the floor, as shown on Fig. 2c.
of the airflow creates an impregnable barrier, which could       The velocity of the air current near the flow must reach 2
be compared to a waterfall, cutting off air currents between     m/s.Use a handkerchief to find the airflow separation plane,
the premises with different air pressures and microclimate.      as shown on Fig. 3.


The airflow created by the curtain must be inclined in such




                                                                                                                           11
     Selecting the right air curtain


A properly selected air curtain is a guarantee of                effectively as those with air heating, but in some situations
optimum efficiency and comfort. First, attention should be       an unheated airflow of the air curtain might create a feeling
directed to the air current structure, its pulse and noise       of draft.
level. However, in addition to this, external factors must       An additional warm airflow creates a feeling of comfort and
also be considered, such as velocity and direction of the        fits nicely into the heating system of the building, as well as
wind, pressure and temperature differential, frequency and       drying the area adjacent to the door.
duration of door openings and so on.                             The necessary level of air flow heating is determined based
                                                                 on several factors: is the air curtain the sole source of heat-
An air current with a small airflow does not eliminate floor     ing in the premises? What is the air-temperature differential
drafts. An excessively powerful air curtain, placed over a       between the hot and cold areas? What is the correspon-
low doorway, will cause discomfort to the people passing         ding energy cost?
underneath it and will create excessive noise in the premis-     Air curtains with a water-based air-heating system provide
es.                                                              a far greater heat pick-up capacity than their electrical
The best result is achieved when the entire doorway is           equivalents.
blocked by a strong and stable airflow. This can be
achieved by placing several air curtains in a row.

Please note that air curtains can be used in any situation
where zones with varying temperatures have to be separat-
ed, regardless of the climate zone.

The Systemair range of air curtains includes models both
with and without an air-heating element.
Air curtains with no heating element eliminate heat loss as

                The main criteria for air curtain selection are:
                “        The purpose (where is it going to be placed? What type of premises will be serviced by it?)
                “        The height and width of the doorway
                “        Installation type: horizontal or vertical
                “        Air curtain type: without a heating element, with electrical heating, with water-based heating.




             MTV                                              MTV41, MTV61




              HF/                                  HF0, HF0L, HFWV, HFLWV
              HFW


             PGD/                          PGD0, PGD9, PGDL0, PGDWV, PGDLWV
             PGDW

              PG/
                                                  PG0, PG9, PGL0, PGWV, PGLWV
              PGW

              HD/
                                               HD0, HD0L, HDWV, HDWVL
              HDW


              PBD                                  PBD0, PBDL0


              PB                                      PB0, PBL0

                            0,0м          1,0м           2,0м          3,0м          4,0м           5,0м        6,0м
                                                               Ширина двери, м
              Fig. 4. The selection of air curtains for vertical installation depends on the width of the doorway.



12
                                                                                 Selecting the right air curtain


Air curtain air-consumption calculation                                     each side of the air curtain. ΔT is also a very important fac-
Estimation of air curtain effectiveness is based on two main                tor in air-curtain design.
factors – air consumption (m3/h) and airflow velocity (m/s). It             For air curtains with electrical heating elements it is not diffi-
is also possible to use the term “pulse”, which is measured in              cult to calculate the air-heating coefficient, knowing the air
kgm/s and defines the response of the air screen.                           curtain power (P) and air consumption (q).
Based on many years of experience, Systemair can boldly
claim that it has achieved an excellent balance between                                                      P (kW), q (m3/c)
these two factors and has attained an optimal value of the
pulse.                                                                      Factor 1.2 – the approximate value of density (p) x Heating
                                                                            ability (Cp) of the warm air.
The velocity of the air current is very difficult to measure                (Example: P=12 kW
accurately, especially outside the lab, where it is impossible              q = 2,700 m3/h = 2,700/3,600 = 0.75 m3/c
to account for all parameters affecting the measurement                     ΔT = 12/(0.75*1.2) = 13.3 °C
results. The structure of the airflow is never perfectly uniform
and varies over the entire span of the air screen, experienc-               The power and heating of the air flow can be far greater if
ing significant changes near grilles and when encountering                  air curtains with water-based heating elements are used,
external airflows.                                                          but they are strongly dependent on the heat-carrying ele-
However, the volume of the flow can be accurately measured                  ment of the system.
in Systemair’s AMCA-certified lab, which develops, research-
es and tests its products.

The air current velocity at the entrance is calculated on the
basis of volume flow and the area of the exit aperture.


v - airflow velocity (m/s)
Q - volume flow (m3/s)
A – the area of the flow (m2)

Air curtains with heating
elements dry the area
adjacent to the exit doors,
increase the feeling of comfort in the room and comple-
ment the existing heating system in the premises. The air-
heating, ΔT - temperature differential between the areas on


                                                                                                                                MTV
                                                                                          PG/PGW
                                                                        HD/HDW           PGD/PGDW            HF/HFW
                          PM        AS     LG/LGW PB/PBD

                   0,0м

                   1,0м
 Высота двери, м




                   2,0м

                   3,0м

                   4,0м

                   5,0м

                   6,0м



                      Fig. 5. The selection of air curtains for horizontal mounted air curtains for various heights of doorway.



                                                                                                                                          13
     Title                  Assembl Heating           Air consump- Length of Length of                  Heating power          Voltage
                            y                             tion, (  airflow (m) air curtain                  (kW)
                                                          m3/h)                   (mm)                                           (V)
     AS Series ........................................................................................................
                                      AS90LV                                              625/820                2,5             900
     3203                   383,0
     AS90HV                                            700/110                2,5           900           without heating       230~1
     AS120LV                                          900/1350                2,5          1200           without heating       230~1
     AS120HV                                         1100/1400                2,5          1200           without heating       230~1
     LG Series / LGW/
     LGO                                              950/1450                2,5          1024           without heating       230~1
     LG0L                                            1200/1200                2,5          1535           without heating       230~1
     LG0XL                                           1900/2900                2,5          2024           without heating       230~1
     LG3                                              950/1450                2,5          1024                    3           400 3N~
     LG6                                              950/1450                2,5          1024                    6           400 3N~
     LG9                                              950/1450                2,5          1024                    9           400 3N~
     LG8                                             1200/2000                2,5          1535                    8           400 3N~
     LG12                                            1200/2000                2,5          1535                   12           400 3N~
     LG9XL                                           1900/2900                2,5          2024                    9           400 3N~
     LG15XL                                          1900/2900                2,5          2024                   15           400 3N~
     LGW                                               600/900                2,5          1024           see Table, p. 25      230~1
     LGWL                                             900/1300                2,5          1535           see Table, p. 25      230~1
     PM Series
     PM2                                               200/400                1,5           806                    2            230~1
     PM3                                               200/400                1,5           806                    3            230~1
     PM5                                               350/500                1,5           806                  4,5            230~1
     PB/PBD Series
     PB0/PBD0                                         950/1200                2,5          1020           without heating        230~1
     PBL0PBDL0                                       1200/1900                2,5          1500           without heating        230~1
     PB3/PBD3                                         950/1200                2,5          1020                    3         230~1/400~3N
     PB6/PBD6                                         950/1200                2,5          1020                    6            400~3N
     PB9/PBD9                                         950/1200                2,5          1020                    9            400~3N
     PBL9/PBDL9                                      1200/1900                2,5          1500                    9            400~3N
     PBL14/PBDL14                                    1200/1900                2,5          1020                  13,5           400~3N
     PG/PGW and PGD/PGDW Series
     PG0/PGD0                                        1200/2400                 4           1020           without heating       230~1
     PGL0/PGDL0                                      2500/3900                 4           1560           without heating       230~1
     PG9/PGD9                                        1400/2300                 4           1020                    9           400 3N~
     PGL14/PGDL14                                    2500/3900                 4           1560                 13,5           400 3N~
     PGW/PGDW                                        1000/2100                 4           1020           see Table, p. 62      230~1
     PGLW/PGDLW                                      1700/3600                 4           1560           see Table, p. 62      230~1
     PGWV/PGDWV                                       900/1800                 4           1020           see Table, p. 62      230~1
     PGLWV/PGDLWV                                    1300/2900                 4           1560           see Table, p. 62      230~1
     HD/HDW Series
     HDO                                              900/1800                3,5          1000           without heating       230~1
     HDLO                                            1300/2700                3,5          1700           without heating       230~1
     HD8                                              900/1800                3,5          1000                    8           400 3N~
     HD12                                            1300/2700                3,5          1700                   12           400 3N~
     HDW                                              800/1700                3,5          1000           see Table, p. 83      230~1
     HDWL                                            1200/2500                3,5          1670           see Table, p. 83      230~1
     HDWV                                             800/1700                3,5          1000           see Table, p. 83      230~1
     HDWVL                                           1200/2500                3,5          1670           see Table, p. 83      230~1
     HF/HFW Series
     HFO                                             1350/2700                 4           1000           without heating       230~1
     HFL0                                            2250/4500                 4           1670           without heating       230~1
     HF12                                            1350/2700                 4           1000                   12           400 3N~
     HFL18                                           2250/4500                 4           1670                   18           400 3N~
     HFW                                             1050/2400                 4           1000           see Table, p. 90      230~1
     HFLW                                            1800/4000                 4           1670           see Table, p. 90      230~1
     HFWV                                            1050/2400                 4           1000           see Table, p. 90      230~1
     HFLWV                                           1800/4000                 4           1670           see Table, p. 90      230~1
     MTV Series
     MTV41                                               5700                  6           1040           without heating       230~1
     MTV61                                               8500                  6           1560           without heating       230~1

                                - with electrical heating                                  ambient air flowing
                                - with water heating




14
 Temperature           Noise level     Protection Product iden-               Price
   increase             (dB(A))          index      tification               (Euro)
      (°C)                                           number                                               LG
                                                                                               (for doorways up to 2.5 m)
without heating          230~1       without heating      53                  IP24

without heating           60              IP24           3204                418,0              Systemair’s LG air curtains are the lead-
without heating           55              IP24           3205                439,0              ing seller and the most recognizable
without heating           60              IP24           3206                492,0              model on the market. It is recommend-
                                                                                                ed to use these air curtains to protect
without heating          41/53            IP24           3027                 539,0             doorways up to 2.5 m in height. 12 stan-
without heating          38/52            IP24           3028                 783,0             dard sizes, casing lengths and air-heat-
without heating          45/56            IP24           3050                1028,0             ing systems are available from stock.
      9/6                42/53            IP21           3042                730,0              Due to the wide range of options,
     17/12               42/53            IP21           3043                804,0              space-saving design and time-honored
     28/19               42/53            IP21           3201                864,0              Swedish quality, these air curtains are
     22/11               38/52            IP21           3029                1066,0             widely used in shops, malls, cafes,
     33/17               38/52            IP21           3032                1114,0             restaurants and even in industry, for
     14/9                45/56            IP21           3048                1379,0             example, as protection for refrigeration
     16/12               45/56            IP21           3049                1486,0             chambers.
see Table, p. 25         40/48            IP24           3031                 804,0
see Table, p. 25         42/50            IP24           3033                1114,0

      30/15              38/48            IP21           3207                336,0
      45/22              36/48            IP21           3208                359,0
      29/18              39/50            IP21           1041                395,0

without heating          45/50            IP44         3955   /   2163    539,0 / 693,0
without heating          40/50            IP44         3956   /   2351    783,0 / 987,0
      9/6                45/50            IP21         2149   /   2164    730,0 / 883,0
     17/12               45/50            IP21         3322   /   2140    804,0 / 957,0
     26/18               45/50            IP21         3323   /   2077   864,0 / 1016,0
     17/12               40/50            IP21         3324   /   2085   1114,0 / 1318,0
     30/20               40/50            IP21         3325   /   2079   1189,0 / 1393,0

                         52/68            IP23         4637   /   9537   1203,0   /   1374,0
                                                                                                       LG new design!
                         60/71            IP23         4639   /   9538   1677,0   /   1906,0
       19/11             52/68            IP23         4641   /   9540   1731,0   /   1902,0
       18/11             60/71            IP23         4643   /   9592   2218,0   /   2446,0
see   Table, p.   62     53/67            IP23         4645   /   9626   1703,0   /   1873,0
see   Table, p.   62     50/64            IP23         4647   /   9630   2326,0   /   2555,0
see   Table, p.   62     47/64            IP23         4632   /   9634   1758,0   /   1928,0
see   Table, p.   62     54/64            IP23         4634   /   9653   2434,0   /   2663,0

without heating          44/62            IP24           3053                1316,0
without heating          45/63            IP24           3057                1836,0
     27/13               44/62            IP24           3060                1893,0
     27/13               45/63            IP24           3170                2425,0
see Table, p. 83         44/62            IP24           3055                1864,0
see Table, p. 83         45/63            IP24           3169                2545,0
see Table, p. 83         44/62            IP24           3209                1924,0
see Table, p. 83         45/63            IP24           3210                2663,0

without heating          44/62            IP24           7975                1739,0
without heating          45/63            IP24           7976                2516,0
     27/13               44/62            IP24           7977                2458,0
     27/13               45/63            IP24           7978                3338,0
see Table, p. 90         44/62            IP24           7971                2413,0
see Table, p. 90         45/63            IP24           7973                3407,0
see Table, p. 90         44/62            IP24           7972                2501,0
see Table, p. 90         45/63            IP24           7974                3642,0

without heating         max. 60           IP44           3074                1986,0
without heating         max. 62           IP44           3076                2649,0

  - horizontal assembly only                           - can be horizontally and vertically
  - vertical assembly only                             mounted




         15
           LG
(for doorways up to 2.5 m)                    AS (for doorways up to 2.5 m)
                                                                              AS - easy mounted fully-sized air curtain
                                                                              without heating. Fully ready for exploita-
    You made LG a popular brand name.                                         tion and supplied with cord and plug. A
    Systemair values your choice and your                                     perfectsolution for air conditioned premis-
    opinion. As we aspire to excellence, we                                   es or large, cooled shop windows and
    always meet our Customer’s demands.                                       refrigeration chambers.
    This is precisely why in 2008 Systemair
    presented its new design for the popu-
    lar LG air curtain.

    Now the best-selling model appears in
    a new modern casing, equipped with
    an adjustable air distribution grille.

                                                      Portier Mini            Portier Mini is the smallest air curtain of
                                              (for doorways up to 1.5 m)      the Systemair family. It is installed inside
                                                                              small shops, kiosks and other premises
                                                                              with a small number of doorways and
                                                                              windows, up to 1.5 m in height. The 3 and
                                                                              5 kW models provide significant warmth
                                                                              to the premises and can be installed
                                                                              instead of a fan heater.




                                              Portier Basic and Portier Basic Design (for doorways up to 2.5 m)

                                                                              The most elegant model on the market.
                                                                              The casing has equally appealing panels
                                                                              on both sides, which means that the air
                                                                              curtain is perfectly suited for installation in
                                                                              modern rooms with glass doors and
                                                                              walls.
                                                                              For doorways up to 2.5 m in height, it is
                                                                              recommended to use Portier Basic and
                                                                              Portier Basic Design models. Air is
                                                                              sucked through the upper part of casing.




                                               Portier Grand and Portier Grand Design (for doorways up to 4 m)

                                                                              Portier Grand and Portier Grand Design
                                                                              are more powerful models for entrances
                                                                              and exits up to 4 m in height. They are a
                                                                              cumulation of all the advantages con-
                                                                              tained in the Portier Basic series.
                                                                              Aside from the stylish design, another sig-
                                                                              nificant advantage of these series is the
                                                                              ability to mount these curtains vertically in
                                                                              a column, next to the doorway.
For gates of malls, car-care centersHD (for doorways up to 3.5 m)
or warehouse facilities with gateway
heights ranging from 2.5 to 3.5 m,
the powerful HD air curtain is pro-
posed. These models can be
equipped with an electrical or water-
based heating element.
These air curtains can be stacked
both horizontally and vertically in a
column, on one or both sides of a
gate, depending on its width.




HF is a powerful air curtain designed     HF (for doorways up to 4 m)
to protect mall and warehouse entry
gateways up to 4 m in height. In
small industrial facilities, these cur-
tains can be used for dehumidifying
and warming up the premises.
Models with no heating element can
effectively protect freezer rooms and
air-conditioned premises from loss of
cold air.




                      MTV Industrial (for doorways up to 6 m)
For large industrial, storage and load-
ing terminals, with gateways reaching
6 m in height, we recommend using
Sytemair’s most powerful air curtain –
MTV.
This model is not equipped with a
heating element, because the large
volume of the airflow, reaching 8,500
m3/h, generated by the axial fans pro-
vides a reliable barrier from the cold
air on the street.
           LG - Park-hotel “Anapa”, Anapa




                                                   Systemair energy saving
                                                Every one of us has thought about the prob-
                                                lem of power saving at some point in time.

                                                Lately the problem has become even more
                                                topical as the cost of electrical energy
                                                spent on various needs, heating (cooling)
                                                being among the most significant, is con-
                                                stantly on the rise.

                                                Stop and think for a moment about the
                                                immense amount of electrical power and
                                                money needed to maintain a certain tem-
                                                perature in, let’s say, a mall, a supermarket
                                                or a business centre.

                                                Clients, who care about lowering their oper-
                                                ational costs and conserving energy,
                                                choose Systemair curtains.




                   LGW in the shopping center


                                                 Systemair cares about your
                                                           health
                                                Everybody knows that in order to be healthy
                                                and productive, humans need to breathe
                                                clean air. We spend 90% of our time inside
                                                and hence it’s crucial for us to be sure of
                                                the quality of the air we breathe.

                                                Bad ventilation leads to increased humidity
                                                and dampness on the premises and can
                                                lead to increased anxiety, fatigue and even
LG. Manas Airport, Bishkek, Kyrgyzstan. 21      allergies, especially in children. Therefore it
Systemair LG air curtains are installed here    is highly important to keep the air clean
                                                inside the building.

                                                Systemair curtains placed at the entrance
                   LG. MEGA Shopping center,
                                                to the premises prevents polluted air from
                          Almaty, Kazakhstan
                                                the street destroying the building’s microcli-
                                                mate.
  By using Systemair cur-
         tains you:

- lower heat loss through open doors by
90%

- lower annual energy costs on heating /
cooling of your premises                                                 LG - Expocenter, Moscow

- save on servicing

                                           LG - Almaty Airport,
                                           Kazakhstan




                                                                    LG - Gran Bank, Yekaterinburg




                                           LG - Antey Shopping and Leisure
                                           Center, Yekaterinburg
Air curtains
     AS



                                                                                                                      Танген
                                                                                                                    циальный
                                                                                                                    вентилятор




                                                                                                                  Горизонтальный
                                                                                                                      монтаж




      Advantages

      • for doorways up to 2.5 m
      • built-in control system
      • low-noise crossflow fan
      • air discharge plane can be displaced under the
      required angle
      • possibility of installation directly under the ceiling
      • additional accessories are not required (the air
      curtain comes complete with mounting brackets,
      power-supply cord and plug)
                                                                      Air velocity profile


Recommended application
AS - easy-mounted full-size air curtain without heating.         Assembly
Specifically designed to prevent cool air from escaping out-     AS air curtains are mounted on top of doorways with mini-
side and warm, polluted air from entering the premises with      mal distance from the doorway. The frontal air intake allows
doorways up to 2.5 m in height. Aperfect solution for air-       the mounting of the curtain right below the ceiling, saving
conditioned premises or large, cooled, shop windows and          extra space.
refrigeration chambers. The casings are supplied in two dif-     AS air curtains can not be installed in a vertical position due to
ferent lengths and two standard sizes of electric motor with     the design features of its bearings.
a high (HV) and low (LV) speed.                                  In order to raise the efficiency of protection, the air-dis-
                                                                 charge grille has an adjustable inclination angle. Air cur-
Construction                                                     tains can be built into a false ceiling.
The fan, motor and two-step switch (max. and min.) are           If the AS air curtain is meant to protect a freezer room, it
installed in a corrosion-proof casing made from galvanized       should be mounted on the “warm” side of the premises.
steel and covered with powder paint. Supplied with cord
and earthed DIN plug.                                            Certificates
                                                                 Certificate of Conformity of the Russian Federation,
Motor                                                            Ukraine, SEMKO and CE Standard
Air curtains are equipped with a low-noise crossflow fan.


Speed control
AS air curtains have a in-built control system and do not
need additional accessories.



20
                                                                                                                         AS

                                                 Basic dimensions




                                                       Specifications



                                                AS90LV                 AS90HV              AS120LV             AS120HV
 Length                               mm        900                    900                 1200                1200
 Power, heater                        kW        -                      -                   -                   -
 Power, motor                           W       92                     115                 104                 127
 Voltage                                V       230~1                  230~1               230~1               230~1
 Current                                A       0.40                   0.50                0.45                0.55
 Air consumption (low / high)        m3/h       625/820                700/1100            900/1350            1100/1400
 Noise level                        dB(A)       53                     60                  55                  60
 Weight                                kg       8.7                    11.8                11.4                13.0
 Protection level                               IP24                   IP24                IP24                IP24
 Product identification number                  3203                   3204                3205                3206
 Price                               Euro       383,0                  418,0               439,0               492,0




Accessories
ATTENTION! All parts necessary for a standard wall mounting are
included in the supply set. For a ceiling installation ASCB brackets
must be ordered.




                                                                               AS curtain with no heating element - an ideal solu-
ASCB ceiling brackets, p.                                                      tion for protection of a supermarket’s refrigerated
          119
                                                                               sections.

                                                                                                                              21
Air curtains
     LG


 New gn!
     i
  des
                                                                                                                     Танген
                                                                                                                   циальный
                                                                                                                   вентилятор




                                                                                                                 Горизонтальный
                                                                                                                     монтаж




                                                                                                                 Electrical heating




                                                                                                       LG
Advantages
• all advantages of the previous LG model
• new stylish design
• extended length of air curtains for reliable protec-
tion of doorways
• increased air consumption
air-discharge grille can be adjusted




                                                                        Air velocity profile


Recommended application                                        heating strength of the element. The MP-I control panel can
LG curtains are recommended for protection of doorways         be attached to the casing of the LG model with an electric
up to 2.5 m in height, in shops, restaurants and cafes. For    heater. The MP20 (MP30 or MPO-I) control panel can be
protection of cool zones from warm air, LG0 (LG0L,             used to regulate curtains with no heating element. A single
LG0XL) models with no heating element can be used.             automated control module can operate up to 4 LG air cur-
Typical uses for the LG0 curtain are at the entrance to the    tains simultaneously. The control devices for the curtain are
refrigerator rooms and air-conditioned premises.               described on pages 111 to 117.
Construction                                                   Assembly
12 standard sizes, casing lengths and air-heating systems      The frontal air intake allows the air curtain to be installed
are available from stock. The fan, motor, heating elements     right beneath the ceiling. The curtains of this series can be
(except LG0, LG0L, LG0XL) are installed in a corrosion-        built into a false ceiling. It is not recommended to mount
proof steel casing, covered with powder paint. The new         the device higher than 3 m off the floor.
modification of the LG model has an elegantly curved cas-
ing and is equipped with an adjustable air-discharge grille.   Certificates
                                                               Certificate of Conformity of the Russian Federation,
Motor
                                                               Ukraine, SEMKO and CE Standard
Air curtains are equipped with a low-noise crossflow fan.



Speed control
Automatics must be ordered separately. The MP22 (or
MP32) controls can be mounted on a wall and could be
connected to the SR series thermostat, to regulate the


22
                                                                                                                               LG

                                                              Basic dimensions

                                                   274




                                 18




                                                               279
                                                      175                                1024/1535/2024




                                                              Specifications


                                                  LG0                LG3             LG6                  LG9        LG0L
 Length                                mm         1024               1024            1024                 1024       1535
 Power, heater                          kW        -                  3               6                    9          -
 Power, motor                            W        92                 92              92                   9          138
 Voltage                                 V        230~1              400 3N~         400 3N~              400 3N~    230~1
 Current                                 A        0.4                4.7             8.3                  13.4       0.6
 Air consumption (low / high)         m3/h        950/1450           950/1450        950/1450             950/1450   1200/2000
 Temperature increase                   °C        -                  9/6             17/12                28/19      -
 Noise level                      dB(A)           41/53              41/53           41/53                41/53      38/52
 Weight                                 kg        16,4               18              18                   19         24
 Protection index                                 IP 24              IP21            IP21                 IP21       IP24
 Product identification number                    3027               3042            3043                 3201       3028
 Price                                Euro        539,0              730,0           804,0                864,0      783,0



                                                  LG8                LG12        LG0XL                LG9XL          LG15XL
 Length                                mm         1535               1535        2024                 2024           2024
 Power, heater                          kW        8                  12          -                    9              15
 Power, motor                            W        138                138         184                  184            184
 Voltage                                 V        400 3N~            400 3N~     230~1                400 3N~        400 3N~
 Current                                 A        11.9               17.7        0.8                  13.9           21.7
 Air consumption (low / high)         m3/h        1200/2000          1200/2000   1900/2900            1900/2900      1900/2900
 Temperature increase                   °C        22/11              33/17       -                    14/9           16/12
 Noise level                          dB(A)       38/52              38/52       45/56                45/56          45/54
 Weight                                 kg        29                 29          33                   38             35
 Protection index                                 IP21               IP21        IP24                 IP21           IP21
 Product identification number                    3029               3032        3050                 3048           3049
 Price                                Euro        1066,0             1114,0      1028,0               1379,0         1486,0



Accessories



 MP Control panels, p. 114       SR electronic thermostats,
                                           p. 117


                                                                                                                                 23
Air curtains
     LG

Assembly                                                             maximum section of 16 mm2, and the control module con-
The air curtain is mounted in a strictly horizontal fashion, so      nector point is meant for a cable with a maximum section
that the air-discharge grille is facing down. In wide door-          of 6 mm2.
ways several curtains must be placed closely one next to
the other. The air curtain can be placed right next to the           Overheating
ceiling or mounted into a false ceiling.                             The heat curtain has a temperature limiter. When the ther-
Mounting on a wall or beam:                                          moswitch activates, the system can be unlocked through
1. Installation on two holes in the back panel (4 for LGXL).         the following procedure:
Screw size – M6.                                                     1. Turn off the power via the main switch.
2. Screwing to a wall or beam. 4 holes, drilled to fit M6            2. Find the cause of the malfunction and fix it.
screws, must be used for a 1 m long curtain (M8 for                  3. Unlock the thermoswitch by pressing the red button
LGXL).                                                               behind the air intake grille, to the right.
                                                                     4. The motor has an inbuilt thermoswitch as well, which
Installation into a false ceiling.                                   turns off automatically when the motor coil cools down.
Sufficient air supply must be provided into the curtain to
keep it from overheating.
A ventilation grille in a false ceiling can provide a sufficient
supply of air. The distance between the ventilation grille
and the air-discharge grille of the curtain is irrelevant.
To mount the air curtain behind a false ceiling the only
additional requirement is for a standard protection grille.
The stipulated gaps between the floor, walls and the curtain
must be observed during assembly.

Electrical connection
The installation is performed after the entire electrical circuit
has been shut down on the main switchboard. There are 6
(7 for LGXL) apertures at the front of the curtain for the
connection of 29 mm power-supply and control-module
wires. The entry connector point is meant for a cable with a


                                                                    The control panel
                                                                    A single control panel can operate 4 air curtains. There
                                                                    two types of control panel - one can be inbuilt into the
                                                                    casing of the curtain, while the other is external. The con-
                                                                    trol panel is ordered separately.




     Fig. A. Installation into a false ceiling




                                                                      Minimal distance
                                                                      during assembly




24
                                                                                                                                                                                                                                                  LG

                                                                                                                             Electric circuits


LG + MP22 control panel
                                                                                       400V3~                                                                           N          400V3~




                                                                    N P                  L1L2L3                                                                     N P            L1L2L3


                M                                                                                                                    M                                                            MP 22
                                      °C                                                                                                                  °C
                ~                                            °C                                                                      ~                             °C
                                                                                LG12




                                                                                                                                                                            LG12
                         Brown




                                                                                                                                             Brown
                 Black




                                                                                                                                     Black
                                   Blue




                                                                                                                                                       Blue
                                                                                                                                                                                                              0
                         3(4) μF




                                                                                                                                             3(4) μF
                 6 μF




                                                                                                                                     6 μF
                                          K1                   K2                                                                                             K1   K2
LG3                                                                                                                   LG3
LG6                                                                                                                   LG6
LG9                                                                                                                   LG9                                                                                 1 1 2 3 4 4 5     7 7 8 9 10 10 11 11
LG8           1 2 3 4 5 6 7 8 9 10 11                                                                                 LG8      1 2 3 4 5 6 7 8 9 10 11
LG12                                                                                                                  LG12




LG + MP22 control panel + SR12 thermostat
                                                                                         N               400V3~




                                                                                       N P               L1L2L3


                                    M                                                                                        MP 22
                                                                   °C
                                    ~                                               °C
                                                                                                  LG12




                                                                                                                                                                                                      SR 12
                                               Brown
                                      Black


                                                           Blue




                                                                                                                                                  0
                                                                                                                                                                                                                  HI   LO
                                               3(4) μF
                                     6 μF




                                                                    K1              K2
       LG3                                                                                                                                                                                                                   °C
       LG6
       LG9                                                                                                                           1 1 2 3 4 4 5                          7 7 8 9 10 10 11 11
       LG8               1 2 3 4 5 6 7 8 9 10 11                                                                                                                                                            1 1 2 3 4 5 6 7 L L N
       LG12




LG + MP-I control panel                                                                                                                                                                                                     LG in the cafe
                                                                                              N                  400V3~




                                                                                              N P                L1L2L3


                                          M                                °C
                                          ~                                              °C
                                                                                                          LG12
                                                         Brown
                                              Black


                                                                        Blue
                                                         3(4) μF
                                            6 μF




                                                                               K1            K2
  LG3
  LG6
  LG9
  LG8                          1 2 3 4 5 6 7 8 9 10 11
  LG12




       MP-I
                             21 22 23 24 25 26 27 28




                                                                                                                                                                                                                                                   25
Air curtains
                     LGW


     New gn!
         i
      des
                                                                                                                     Танген
                                                                                                                   циальный
                                                                                                                   вентилятор




                                                                                                                 Горизонтальный
                                                                                                                     монтаж




                                                                                                                    Водяной
                                                                                                                     нагрев




                                                                                                       LGW
Advantages
• all advantages of the previous LGW model
• new stylish design
• extended length of air curtains for reliable protec-
tion of doorways
• increased air consumption
air-discharge grille can be adjusted




                                                                       Air velocity profile




Recommended application                                        SR12 thermostat.
LGW air curtains are recommended for protection of door-
ways up to 2.5 m in height. The LGW models use hot             Assembly
water from the central heating system as a heat carrier.       The frontal air intake allows the air curtain to be installed
                                                               right beneath the ceiling. LGW has a water circuit protec-
Construction                                                   tion filter. The curtain connects to the central water-heating
New LGW models come in two standard dimensions, with           circuit through the DN 15 couplings in the upper part of the
different casing lengths. The crossflow fan and heating ele-   casing. Maximum water temperature is 100 °C.The hot
ments are mounted inside a corrosion-proof, curved casing      water is fed through the DN 15 couplings (with internal con-
from stainless steel, covered with powder paint. LGW has a     nection thread) in the upper part of the casing. The water
water-based heating system, with hot water supplied from       may flow in any direction..
the building’s central heating system. Heat pickup capacity
of the curtain depends on the water temperature in the cir-    Certificates
cuit and the air temperature at entry into the curtain.        Certificate of Conformity of the Russian Federation,
                                                               Ukraine, SEMKO and CE Standard
Motor
The curtains are equipped with a low-noise crossflow fan
and an adjustable air-discharge grille.
Speed control
The control panel MP20 (or MP30, MP0-I) regulates the
joint action of up to 4 LGW air curtains. The water con-
sumption can be regulated by the FHW2RV valve with


26
                                                                                                                      LGW


                                                             Basic dimensions
                                        274

                                              189


                          18




                                                     279
                                              175                                   1024/1535




                                                                  Specifications

                                                                               LGW                   LGWL
    Length                                                 mm                  1024                  1535
    Voltage                                                  V                 230~1                 230~1
    Power, motor                                             W                 115                   138
    Current                                                  A                 0.37                  0.6
    Air consumption (low / high)                           m3/h                600/900               900/1300
    Noise level                                        dB(A)                   40/48                 42/50
    Weight                                                  kg                 18                    26
    Protection index                                                           IP24                  IP24
    Product identification number                                              3031                  3033
    Price                                                  Euro                804,0                 1114,0




                                 Each manufactured Systemair curtain is tested individually.
                                 You can always count on the quality of Systemair products




Accessories




  MP Control panels, p.        SR electronic ther-    FHWACT - actua-    FHW2RV         FHWAV       FHWSV stopping
         114                    mostats, , p. 117       tor, p. 118        Control valves, p. 118     valve, p. 118

                                                                                                                        27
Air curtains
                      LGW

Assembly                                                               the lower part of the inflow tube. The connection zone
During the installation, provision should be made for an               becomes accessible after the front grille is removed.
adequate water supply to the upper part of the frame. The              ATTENTION! Any works in the connection area can be per-
curtain can be mounted into a false ceiling. To achieve its            formed by qualified personnel only. Prior to conducting any
maximum effectiveness, the curtain must cover the entire               works, the current in the unit must be cut-off. Never allow
width of the doorway. The air curtain is installed in a strictly       the electrical connectors to come in contact with water.
horizontal position, with the air grille facing down. Several
air curtains must be installed closely side by side in wide            The control panel
doorways to prevent gaps in the airflow. The air curtain               A single control panel can operate 4 air curtains. It is sup-
can be installed right underneath the ceiling, due to the              plied in two designs, one built into the casing (MP0-I) and
frontal air intake.                                                    an external version (MP20 or MP30). The control panel is
                                                                       ordered separately.
Mounting on a wall or beam:
1. Mounting on two holes in the back panel. Screw size –
M6.
ATTENTION! If the curtain is mounted on the holes in the
back panel, it must be protected from falling - use the two
safety clamps supplied with the unit. They can be installed
on top.
2. Screwing to a wall or beam. Four holes, drilled to fit M6
screws, must be used for a 1 m long curtain.

Electrical connection
The fan motor connects to a power outlet via a cable with a
plug for a
230 V socket. There are several holes in the upper part of
the casing to lead the cable outside. The control panel
must be connected by a qualified electrician in accordance
with current rules.
                                                                               Minimal distance
                                                                               during assembly
Connection of water supply to LGW
The pump for hot water connects to the upper part of the
unit with two connected flanges with an R15 threading. The
water drainage stopper is located near the connection in



                                                              Water circuit

                                                              A
          A - stopping valve
                                                                                    C
               (FHWSV20/25)
          B - Control valve                                                     D
                                                                   B
               (FHWAV20/25)
                                                                                    C
          C - Two-way control valve                                             E
               (FHW2RV20/25)
          D - Actuator (FHWACT)
          E - Thermostat SR12




         The hot water passes through the
         nozzles with an inner DN15
         threading, which are located in the
         upper part of the curtain.
         The water may flow in any direction.




28
                                                                                                   LGW
                             LGW Pressure differential in the water circuit
    Pressure drop




                                         LGW Heating power and increase of air temperature
                                                           Supply      95/70         80/60        70/50
Air supply 1 = 600 m3/h                             ti°C    of air   Δti°C QkW     Δti°C QkW    Δti°C QkW
Air supply 2 = 900 m3/h                                       1      43.1    8.8   35.6   7.4   30.7   6.2
                                                    0         2      36.4   11.1   30.1   9.7   25.8   7.9
ti°C = Air temperature at the inlet
                                                              1      37.6    7.7   31.0   6.3   25.2   5.1
Δti°C = Increase of air temperature                 +10       2      21.7    9.7   25.5   8.2   21.1   6.4
Q = Heating power
                                                              1      34.8    7.1   28.3   5.7   22.4   4.6
                                                    +15       2      29.3    8.9   23.2   7.5   18.8   5.7
                                                              1      32.1    6.5   25.5   5.2   19.6   4.0
                                                    +20       2      27.0    8.2   20.9   6.7   16.4   5.0




                                         LGWL Heating power and increase of air temperature
Air supply 1 = 900 m3/h
                                                           Supply       95/70        80/60       70/50
Air supply 2 = 1300 m3/h
                                                    ti°C     air     Δti°C QkW     Δti°C QkW Δti°C QkW
ti°C = Air temperature at the inlet
                                                              1      45.0 15.2     38.0 12.9 32.1 10.9
Δti°C = Increase of air temperature                 0         2      39.3 18.7     33.0 15.7 28.1 13.3
Q = Heating power                                             1      39.3 13.3     32.4 11.0 26.5 9.0
                                                    +10       2      34.4 16.3     28.0 13.4 23.1 10.9
                                                              1      36.5 12.4     29.5 10.0 23.7 8.0
                                                    +15       2      31.7 15.1     25.8 12.2 20.6 9.8
                                                              1      33.6 11.4     26.7 9.0 20.8 7.0
                                                    +20       2      29.4 13.9     23.3 11.0 18.1 8.6




                                                                                                             29
Air curtains
                LGW



                                        Electric circuits



         LGW + MPO-I control                                     LGW + MP20 control

                                              MP 20
 MP0-I


                                                            0
              21 22 23 24 25 26 27 28




                                                      1 1 2 3 4 4 5


230V~


        N L    1 2 3 4 5
                                             230V~

                 C1 C2
                                                      N L       1 2 3 4 5              N L   1 2 3 4 5
                   Brown
                   Black


                           Blue




                                                                  C1 C2
                                                                   Brown
                                                                   Black


                                                                           Blue




                   ~
                   M              °C

     LG0
     LG0L                                                          ~
                                                                   M              °C

                                                 LG0
     LGW
                                                 LG0L
     LGWL                                        LGW
                                                 LGWL




                                                                                        LG in a shop




30
                                                Portier




When the air curtain forms a part of your interior...


                Portier Series




                                                        31
                                                     Modern style and Swedish quality
                                                     In recent times designers and architects have
                                                     come to focus on the interior look of modern
                                                     premises, such as hallways in office blocks,
                                                     hotels, malls, restaurant entrances and shops.
                                                     In response to this demand Systemair Company
                                                     offers the Portier series of air-heat curtains.




                                                     The first models in the series where showcased
                                                     back in July 2002, at the international “PlanCon”
                                                     exhibition in Berlin, timed to coincide with the
          PG - Ekonika shoe store (Moscow, Russia)
                                                     world architect summit, and they attracted con-
                                                     siderable interest.




                                                     Portier Design curtains can rightfully be consid-
                                                     ered the most elegant mass-produced models
                                                     on the market. Simple forms and the elegant
                                                     appearance of the polished stainless steel cas-
                                                     ing are now very popular among architects.




                                                     Thinking of saving power – think
                                                     Systemair!
                                                     - You save 90% of heat by using Systemair cur-
     PGD - Keramika store (Yerevan, Armenia)         tains, because their strong and consistent air
                                                     current creates a reliable barrier between the
                                                     premises and the street.

                                                     - You save on heating and cooling the building
                                                     throughout the year. During the cold season the
                                                     air curtains can be used to warm your premis-
                                                     es. And in the summer, you can turn off the
                                                     heating elements and the curtains prevent cool
                                                     air from leaving the building.

                                                     - If your building has a limited supply of electrici-
                                                     ty, you can use Systemair curtains with a water
                                                     heating element and use the extra energy you
                                                     saved on other needs.




 PG - Galleri Royal store (Vilnius, Lithuania)


32
Unique casing design
For doorways up to 2.5 m in height, it is recom-
mended to use Portier Basic and Portier Basic
Design models. Air is sucked through the upper
part of casing.
Portier Grand and Portier Grand Design are more
powerful models for entrances and exits up to 4
m in height. They are a cumulation of all the
advantages contained in the Portier Basic and
Portier Basic Design series.




The casing has equally appealing panels on both
                                                       PG - Perta 57 famous restaurant (Madrid, Spain)
sides, which means that the air curtain is perfectly
suited for installation in modern premises with
glass doors and walls.



Aside from the stylish design, another significant
advantage of the Portier series is the ability to
mount these curtains vertically in a column, next
to the doorway.




Removable panels give you scope
to use your imagination.
Do you know that when you buy a curtain from
the Portier series, you have a unique opportunity
to replace the casing panels to suit the interior
design of your premises?                                       PGD - Havsmak restaurant (Oslo, Norway)

A removable polished steel panel gives a designer
more freedom in creating a unique look for the
premises.




The exceptional, streamlined and modern
design of the casing reflects current trends in
architectural design. The curtain is designed as
a prominent feature of the interior, symbolizing
the modern philosophy of energy conservation.




                                                         PB - Holiday Inn Hotel (Vilnius, Lithuania)

                                                                                                         33
Air curtains
  Portier Mini




                                                                                                                          Танген
                                                                                                                        циальный
                                                                                                                        вентилятор




                                                                                                                      Горизонтальный
                                                                                                                          монтаж




                                                                                                                      Electrical heating




     Advantages
     • for doorways (up to 1.5 m)
     • low noise level
     • corrosion-proof steel casing
     • overheating protection
     • built-in thermostat (additional controls are not
     required)
     • can be mounted near the ceiling
     • fully ready for use (supplied with mounting
     brackets, cord and plug)

                                                                                Air velocity profile




Recommended application                                            (PM2 only); rated air supply and Ѕ the power; rated air sup-
This is the smallest curtain of Systemair air curtain family. It   ply and rated power. The temperature can be regulated in
is installed inside small shops, kiosks and other premises         the range from 0 to 40 °C. Thermal protection is reset by
with a small number of doorways and windows, up to 1.5 m           pressing the red button on the front panel.
in height. The 3 and 5 kW models provide significant
warmth to the premises and can be installed instead of a           Assembly
fan heater.                                                        PM is installed horizontally on the supplied holders. The
                                                                   frontal air intake allows the air curtain to be installed right
Construction                                                       beneath the ceiling. Minimal distances from surrounding
Fan, motor, heating elements and control automation are            obstructions are shown on page 36. The curtain cannot be
mounted inside a curved steel casing with a powder-paint-          installed vertically.
ed coating. It is supplied with mounting brackets, power
cord and plug. Additional control devices are not required.        Certificates
                                                                   Certificate of Conformity of the Russian Federation,
Motor                                                              Ukraine, SEMKO and CE Standard.
The curtain is equipped with a low-noise crossflow fan.



Speed control
The curtain is equipped with a thermostat switch and a
power switch with 5 positions: switched off; Ѕ the rated air
supply and Ѕ the power; Ѕ the air supply and rated power

34
                                                                                Portier Mini


                                              Basic dimensions




                                                  Specifications


PM2                                 PM3              PM5
Length                                 mm            806              806        806
Power, heating                         kW            2                3          4.5
Power, motor                            W            2 x 38           2 x 38     2 x 50
Voltage                                  V           230-1            230-1      230-1
Current                                  A           9.3              13.0       19.6
Air consumption (low / high)          m3/h           200/400          200/400    500
Temperature increase                    °C           30/15            12/23      27
Noise level                          dB(A)           38/48            36/48      50
Weight                                  kg           7.3              7.3        8.4
Protection index                                     IP21             IP21       IP21
Product identification number                        3207             3208       1041
Price                                 Euro           336,0            359,0      395,0




 Accessories

 ATTENTION! All necessary accessories are included in the shipment.



                                                                                           35
Air curtains
  Portier Mini

Assembly                                                         formed via a single-throw switch with a minimal 3 mm con-
For efficient operation, Portier Mini should be placed right     tact gap.
above the doorframe.
                                                                 Overheating
• Drill holes to attach brackets to the wall, observing a 600    If something obstructs the entry or exit of air into the cur-
mm distance between them. Place the brackets up or               tain, an inbuilt thermoswitch activates and Portier Mini shuts
down, in accordance with the minimal distances and limita-       down. To reset the automatic overheating protection
tions, as shown on this page.                                    switch off the power in the curtain and allow it to cool
• Insert the guides of the air curtain into the grooves of the   down. It will restart when the curtain is switched on again.
brackets. Tighten the screws.
• If the curtain is hanging from the ceiling, make sure to
turn the brackets as shown in Fig. (C), to ensure that the
curtain faces directly down.
• When mounting on a beam, baulk or girder, use the holes
in the upper part of the casing (when mounting behind a
suspended ceiling, make sure that the device receives
enough air and no ventilation system interferes with the
operation of the air curtain).

ATTENTION! Do not install the curtain in a manner that
obstructs the entry or exit apertures.
Electrical connection
Portier Mini is supplied with an flexible cord and an earthed
plug. A stationary connection (with no plug) must be per-




                                                                                                      Fig. B




            PM is installed horizontally on the supplied
            holders. The minimal distances to the sur-
            rounding obstructions are shown in the fig-
            ure. The curtain cannot be installed vertically.




                                                                                                       Fig. C




36
                                                                               Portier Mini


                                Electric circuits



                                           PM 2

                                               4
                                               3
                                               2
                                               1



                           c°                      M        M
                                                   ~        ~
    4       X X X X
    3       X     X
                           c°                                             c°
    2       X X
    1           X X
        O                        P N




                                           PM 3

                                           4
                                           3
                                           2
                                           1



                      c°                           M        M
                                                   ~        ~
4       X      X
3              X
                      c°                                             c°
2         X
1       X X X
    O                           P N




                                               PM 5

                                                       c°       c°
                                c      3
                                b      2




                      c°                           M        M
                                                   ~        ~

                      c°                                             c°
2       X
1     X X
    O O O                       P N



                                                                                          37
Air curtains
  Portier Basic




                                                                                                                   Танген
                                                                                                                 циальный
                                                                                                                 вентилятор




                                                                                                               Горизонтальный
                                                                                                                   монтаж




                                                                                                                Вертикальный
                                                                                                                   монтаж




                                                                                                               Electrical heating




     Advantages
     • for doorways (up to 2.5 m)
     • stylish design
     • low noise level
     • corrosion-proof casing made from galvanized
     sheet steel and painted with white enamel
     • overheating protection
     • ease of assembly




                                                                        Air velocity profile



Recommended application                                       ed to an SR thermostat to automatically regulate the heat-
Portier Basic can be rightfully named the most elegant air    ing elements. A single MP control panel can regulate up to
curtain on the market.                                        4 Portier curtains. The air consumption and heating are
They are perfectly suited for glass entrances to shops,       controlled by switches with three positions: 0 - Ѕ - max. The
hotels and restaurants, where the curtain may also be seen    airflow direction is regulated by the discharge grille.
from the street. Portier basic is recommended for protec-
tion of doorways up to 2.5 m in height.                       Assembly
                                                              The curtain can be hung from the ceiling on a pendulum
Construction                                                  hanger or on wall mounted brackets.
Fan, motor, heating elements and control automation are
mounted inside a curved steel casing with a powder-paint-     Certificates
ed coating. The air intake is performed in the top panel of   Certificate of Conformity of the Russian Federation,
the casing. The casing panels are curved. They are easily     Ukraine, SEMKO and CE Standard.
removed, which greatly simplifies technical servicing and
painting. Additional black colored panels can be supplied
on request.

Motor
The curtain is equipped with a low-noise crossflow fan.
Speed control
The fan speed and heating power are regulated by the MP
control panel (additional accessory). MP could be connect-


38
                                                                                                          Portier Basic


                                                     Basic dimensions




                                                        Specifications

                                                    PB0                  PB3                   PB6                  PB9
 Length                                mm           1020                 1020                  1020                 1020
 Power, heating                         kW          -                    3                     6                    9
 Power, motor                             W         92                   92                    92                   92
 Voltage                                  V         230~1                230 - 1/400 3N~       400 3N~              400 3N~
 Current                                  A         0.4                  4,3/13.0              8.7                  13.0
 Air consumption (low / high)          m3/h         950/1200             950/1200              950/1200             950/1200
 Temperature increase                    °C         -                    9/6                   17/12                26/18
 Noise level                          dB(A)         45/50                45/50                 45/50                45/50
 Weight                                  kg         14                   17                    17                   17
 Protection index                                   IP44                 IP21                  IP21                 IP21
 Product identification number                      3955                 2149                  3322                 3323
 Price                                 Euro         539,0                730,0                 804,0                864,0




                                                    PBL0                      PBL9                    PBL14
 Length                                mm           1500                      1500                    1500
 Power, heating                         kW          -                         9.0                     13.5
 Power, motor                             W         92                        92                      92
 Voltage                                  V         230~1                     400 3N~                 400 3N~
 Current                                  A         0.4                       13.0                    19.5
 Air consumption (low / high)          m3/h         1200/1900                 1200/1900               1200/1900
 Temperature increase                    °C         -                         17/12                   30/20
 Noise level                          dB(A)         40/50                     40/50                   40/50
 Weight                                  kg         18,2                      24,7                    24,7
 Protection level                                   IP44                      IP21                    IP21
 Product identification number                      3956                      3324                    3325
 Price                                 Euro         783,0                     1114,0                  1189,0




Accessories




MP Control panels, p. 114   SR electronic ther-   PGT, connecting   PBH pendulum      PBS mounting     PBF removable
                             mostats, p. 117        kit, p. 119     hanging, p. 119     kit, p. 119     panels, p. 119


                                                                                                                               39
Air curtains
  Portier Basic

Assembly                                                          There are several ways the air flow velocity can be con-
Portier Basic is mounted horizontally. Models without a           trolled by an MP series control panel. MP-I, MP22 and
heating element (PB0 and PBL0) can also be installed verti-       MP32 control panels are designed for curtains with an
cally.                                                            electric-heating element. MP0-I, MP20 and MP30 control
                                                                  panels are designed for curtains without heating. MP-I and
The air is sucked in at the top part of the casing and is sup-    MP0-I are built into the casing of the curtain.
plied in a flat, high velocity stream, forming a protective air   A single control panel can regulate up to four Portier cur-
barrier. Therefore Portier Basic must be installed at least 80    tains.
mm away from the ceiling or any other obstruction, stop-
ping the flow of air over the device. The total distance          Overheating
between PB and the wall, PB and the ceiling (or other             Portier Basic is equipped with overheating protection. If
obstruction) must be at least 120 mm (see figure on this          anything obstructs the entry or exit of air into the curtain, an
page).                                                            inbuilt thermoswitch activates and the curtain shuts down.
                                                                  When the protection is activated, allow the device to cool
The curtain is installed horizontally above the doorway so        and then switch on again according to the instructions.
that the air-discharge grille is facing down. In wide door-       It will restart when the curtain is switched on again.
ways several curtains should be hung side by side without
breaks. In this case it is recommended to use the PBT join-
ing kit.

Portier Basic is mounted by using four threaded M6 holes
in upper side of the casing.
The curtain can be fixed in stationary fashion upon a PBH
pendulum hanger from the ceiling or on PBS wall brackets
(a 2 piece set). PBS wall brackets must be ordered sepa-
rately.
The angle of the airflow can be regulated with the dis-
charge grille.

Electrical connection
The curtain must be protected by a three-pole switch, with
a minimal contact gap of 3 mm.




     A = min. 80 mm
     A + B = min. 120 mm


       Minimal distance to the ceiling.




                                                             If the ceiling is too high for a pendulum hanger to be used for
                                                             the PBH, it can be substituted with chains with threaded holes
                                                             (M6).
                                                                For wide doorways the PBT joining kit should be used, joining
                                                             several curtains together.
                                                                The SR12 electronic thermostat must be mounted directly
                                                             near the door.




40
                                                                                              Portier Basic



                              Porter Basic air curtains installation chart


                                                                                PBH Pendulum hanging
                                                                                for ceiling installation
  For wide doorways the PBT joining kit should be used, joining                 PBH
several curtains together.



               PBS wall mounting kit PBS




                                                                      Joining
                                                                      kit PBT




                             MP20 (MP30)        MP22 (MP32)          SR12
                             control panel      control panel      electronic
                                                                  thermostat




                                                                                                  The direction of the
                                                                                                  air current of Portier
                                                                                                  curtains is changed
                                                                                                  by moving the shut-
                                                                                                  ters.




                                                                                                                           41
Air curtains
  Portier Basic


                                                          Electric circuits

 Portier Basic + MP22 control panel + SR12 thermostat


                      MP 22


                                                                                 SR 12
                                    0
                                                                                            HI    LO


                                                                                                        °C


                              1 1 2 3 4 4 5           7 7 8 9 10 10 11 11
                                                                                         1 1 2 3 4 5 6 7 L L N




                  N     400V3~

                                                                                                       PB, PBL
                  N L     L1L2 L3           1 2 4 5 6 8 9 11


                        400V3~


                                                                                                       PB, PBL
                  N L     L1L2 L3           1 2 4 5 6 8 9 11




Portier Basic + MP22 control panel

                                                                                                             Attention
                                        MP 22
                                                                                                             A further step towards saving
                                                                                                             energy costs is to install the
                                                                                                             SR12 integrated thermostat,
                                                      0
                                                                                                             which automatically limits the
                                                                                                             power of the heating element,
                                                                                                             once a comfortable temperature
                                                1 1 2 3 4 4 5      7 7 8 9 10 10 11 11
                                                                                                             is reached by the door.

                                                                                                             The SR12 electronic thermostat
                                                                                                             must be mounted near the door-
                                                                                                             frame.




                                 230V~ 400V3~

                                                                                           PB, PBL
                                    N L     L1L2 L3          1 2 4 5 6 8 9 11


                                            400V3~


                                                                                           PB, PBL
                                    N L     L1L2 L3          1 2 4 5 6 8 9 11




42
                                                                                                                                       Portier Basic


                                                                                Electric circuits


PB 3                                                                                         PB6, PBL9


                                                                           C1                                                                            C1
        N L    L1L2 L3                                                                              N L    L1L2 L3
                          1 2 4 5 6 8 9 11                                                                           1 2 4 5 6 8 9 11

                                         C2                                                                                     C2




                                                            K2                                                                                 K2
                                                                       Brown




                                                                                                                                                     Brown
                                                                       Black




                                                                                                                                                     Black
                                                                       Blue




                                                                                                                                                     Blue
                                                       K1                                                                                 K1
                                    °C
                                                                                                                           °C

                                                                      °C        ~
                                                                                M                                                                             ~
                                                                                                                                                    °C
                                                                                                                                                              M
                                                                                                          kW
                                         PB                                                                                     PB     PBL
                            C1           3 µF
                                                                           PB 3                                       C1        3 µF   4 µF              PB6,
                            C2           6 µF                                                                         C2        6 µF   6 µF              PBL9




PB9, PBL14



                                                                      C1
       N L    L1L2 L3
                         1 2 4 5 6 8 9 11

                                    C2




                                                        K2
                                                                  Brown
                                                                  Black
                                                                  Blue




                                                   K1

                               °C


                                                                 °C             ~
                                                                                M
        kW     kW
                                    PB          PBL
                          C1        3 µF        4 µF                   PB9,
                          C2        6 µF        6 µF                  PBL14




                                                                                                                                                                  43
Air curtains
  Portier Basic Design




                                                                                                                            Танген
                                                                                                                          циальный
                                                                                                                          вентилятор




                                                                                                                         Горизонтальный
                                                                                                                             монтаж




                                                                                                                         Вертикальный
                                                                                                                            монтаж




                                                                                                                         Electrical heating




     Advantages
                                                                                                          PBD     PBDL

     •   for doorways (up to 2.5 m)                                                                       9.0      7.5
     •   exclusive design
                                                                                                          6.5      5.5
     •   low noise level
     •   corrosion-proof steel casing                                                                     4.9      4.3
     •   overheating protection                                                                           4.0      3.6
     •   easy installation (including vertical installation)
                                                                                                          3.5      3.2

                                                                                                          3.0     2.7




                                                                           Air velocity profile


Recommended application                                           nal MP control panel. MP could be connected to an SR12 ther-
Portier Basic Design are air curtains of exclusive design. They   mostat to automatically regulate the heating elements. A single
are perfectly suited for luxury glass entrances in hotels and     MP control panel can regulate up to 4 PBD curtains. The air
restaurants, where the air curtain can also be seen from the      consumption and heating are controlled by switches with three
street. Portier Basic Design is recommended for protecting        positions: 0 - Ѕ - max. The airflow direction is regulated by the
doorways up to 2.5 m in height. The curtain is designed to be a   discharge grille.
prominent part of the interior.
                                                                  Assembly
Construction                                                      The curtain can be hung from the ceiling on a pendulum hang-
Fan, motor, heating elements and control automation are           er or on wall mounted brackets.
mounted inside a curved stainless steel casing. The air intake
is performed in the top panel of the casing. The casing panels    Certificates
are curved.                                                       Certificate of Conformity of the Russian Federation,
                                                                  Ukraine, SEMKO and CE Standard.
Motor
The curtains are equipped with a low-noise crossflow fan
and an adjustable air-discharge grille.

Speed control
The fan speed and heating power are regulated from the exter-



44
                                                                                                        Portier Basic Design

                                                             Basic dimensions




                                                                    Specifications


                                                         PBD0                   PBD3                    PBD6                  PBD9
 Length                                   mm             1020                   1020                    1020                  1020
 Power, heating                            kW            -                      3                       6                     9
 Power, motor                               W            92                     92                      92                    92
 Voltage                                     V           230~1                  230 - 1/400 3N~         400 3N~               400 3N~
 Current                                     A           0.4                    4,3/13.0                8.7                   13.0
 Air consumption (low / high)           m3/h             950/1200               950/1200                950/1200              950/1200
 Temperature increase                      °C            -                      9/6                     17/12                 26/18
 Noise level                           dB(A)             45/50                  45/50                   45/50                 45/50
 Weight                                    kg            14                     17                      17                    17
 Protection index                                        IP44                   IP21                    IP21                  IP21
 Product identification number                           2163                   2164                    2140                  2077
 Price                                  Euro             693,0                  883,0                   957,0                 1016,0



                                                         PBDL0                         PBDL9                    PBDL14
 Length                                  mm              1500                          1500                     1500
 Power, heating                           kW             -                             9                        13.5
 Power, motor                               W            92                            92                       92
 Voltage                                    V            230-1                         400 3N~                  400 3N~
 Current                                    A            0.4                           13.0                     19.5
 Air consumption (low / high)           m3/h             1200/1900                     1200/1900                1200/1900
 Temperature increase                      °C            -                             17/12                    30/20
 Noise level                           dB(A)             40/50                         40/50                    40/50
 Weight                                    kg            18,2                          24,7                     24,7
 Protection index                                        IP44                          IP21                     IP21
 Product identification number                           2351                          2085                     2079
 Price                                  Euro             987,0                         1318,0                   1393,0




Accessories




MP Control panels, p. 114   SR electronic thermostats,        PGT, connecting         PBH pendulum      PBF removable       PBS mounting kit,
                                      p. 117                    kit p. 119            hanging, p. 119   panels, p. 120          p. 119


                                                                                                                                                45
Air curtains
  Portier Basic Design
Assembly                                                          trolled by an MP series control panel.
The Portier Basic Design air curtain is mounted horizontally.     MP-I, MP22 and MP32 control panels are designed for cur-
Models without a heating element (PBD0 and PBDL0) can             tains with an electric-heating element. MP0-I, MP20 and
also be installed vertically.                                     MP30 control panels are designed for curtains without
                                                                  heating. MP-I and MP0-I are built into the casing of the cur-
The air is sucked in at the top part of the casing and is sup-    tain.
plied in a flat, high velocity stream, forming a protective air   A single control panel can regulate up to four Portier cur-
barrier. Therefore Portier Basic Design is installed at least     tains.
80 mm away from the ceiling or any other obstruction,
stopping the flow of air over the device. The total distance      The direction of the air current of Portier curtains is
between PBD and the wall, PBD and the ceiling (or other           changed by moving the shutters.
obstruction) must be at least 120 mm (see figure on this
page).                                                            Overheating
                                                                  Portier Basic Design is equipped with overheating protec-
The curtain is installed horizontally above the doorway so        tion. If anything obstructs the entry or exit of air into the
that the air-discharge grille is facing down. In wide door-       curtain, an inbuilt thermoswitch activates and the curtain
ways several curtains should be hung side by side without         shuts down. When the protection is activated, allow the
breaks. In this case it is recommended to use the PBT join-       device to cool and then switch on again according to the
ing kit.                                                          instructions.
                                                                  It will restart when the curtain is switched on again.
Portier Basic Design is mounted by using four threaded M6
holes in upper side of the casing.
The curtain can be fixed in stationary fashion upon a PBH
pendulum hanger from the ceiling or on PBS wall brackets
(a 2 piece set). PBS wall brackets must be ordered sepa-
rately.
The angle of the airflow can be regulated with the dis-
charge grille.
Electrical connection
The curtain must be protected by a three-pole switch, with
a minimal contact gap of 3 mm.
There are several ways the air flow velocity can be con-




  A = min. 80 mm
  A + B = min. 120 mm


     Minimal distance to the ceiling.



                                                          If the ceiling is too high for a pendulum hanger to be used for
                                                          the PBH, it can be substituted with chains with threaded holes
                                                          (M6).
                                                             For wide doorways the PBT joining kit should be used, joining
                                                          several curtains together.
                                                             The SR12 electronic thermostat must be mounted directly
                                                          near the door.




46
                                                                                Portier Basic Design


                     Porter Basic Design air curtains installation chart
                                             (similar to Portier Basic)

                                                                                PBH Pendulum hanging
                                                                                for ceiling installation
  For wide doorways the PBT joining kit should be used, joining                 PBH
several curtains together.



               PBS wall mounting kit PBS




                                                                    Joining
                                                                    kit PBT




                                   MP20               MP22           SR12
                                   control            control      electronic
                                    panel              panel      thermostat




Portier Basic Design models are
now very popular among designers
and architects. Thanks to their styl-
ish design, the curtains fit wonderful-
ly into your interior.




                                                                                                           47
Air curtains
  Portier Basic Design


                                                      Electric circuits


 Portier Basic Design + MP22 control panel + SR12 thermostat

                      MP 22


                                                                                 SR 12
                                    0
                                                                                           HI      LO


                                                                                                         °C


                              1 1 2 3 4 4 5           7 7 8 9 10 10 11 11
                                                                                        1 1 2 3 4 5 6 7 L L N




                  N     400V3~

                                                                                                        PB, PBL
                  N L     L1L2 L3           1 2 4 5 6 8 9 11


                        400V3~


                                                                                                        PB, PBL
                  N L     L1L2 L3           1 2 4 5 6 8 9 11




Portier Basic Design + MP22 control panel


                                    MP 22



                                                  0




                                            1 1 2 3 4 4 5         7 7 8 9 10 10 11 11




                                230V~ 400V3~

                                                                                         PB, PBL
                                 N L    L1L2 L3            1 2 4 5 6 8 9 11


                                        400V3~


                                                                                         PB, PBL
                                 N L    L1L2 L3            1 2 4 5 6 8 9 11




48
                                                                                                                       Portier Basic Design


                                                               Electric circuits


PBD3                                                                                        PBD6, PBDL9


                                                        C1                                                                                                       C1
       N L   L1L2 L3                                                                                       N L     L1L2 L3
                       1 2 4 5 6 8 9 11                                                                                      1 2 4 5 6 8 9 11

                                  C2                                                                                                    C2




                                              K2                                                                                                       K2
                                                    Brown




                                                                                                                                                             Brown
                                                    Black




                                                                                                                                                             Black
                                                    Blue




                                                                                                                                                             Blue
                                         K1                                                                                                       K1
                             °C
                                                                                                                                   °C

                                                   °C          ~
                                                               M                                                                                                      ~
                                                                                                                                                            °C
                                                                                                                                                                      M
                                                                                                                 kW
                                  PB                                                                                                    PB     PBL
                        C1        3 µF
                                                        PB 3                                                                  C1        3 µF   4 µF              PB6,
                        C2        6 µF                                                                                        C2        6 µF   6 µF              PBL9




                                    PBD9, PBDL14



                                                                                                           C1
                                              N L            L1L2 L3
                                                                       1 2 4 5 6 8 9 11

                                                                                  C2




                                                                                                 K2
                                                                                                       Brown
                                                                                                       Black
                                                                                                       Blue




                                                                                            K1

                                                                             °C


                                                                                                      °C          ~
                                                                                                                  M
                                               kW             kW
                                                                                  PB     PBL
                                                                        C1        3 µF   4 µF               PB9,
                                                                        C2        6 µF   6 µF              PBL14




                                                                                                                                                                          49
Air curtains
  Portier Grand




                                                                                                                             Танген
                                                                                                                           циальный
                                                                                                                           вентилятор




                                                                                                                          Горизонтальный
                                                                                                                              монтаж




                                                                                                                           Вертикальный
                                                                                                                              монтаж




                                                                                                                          Electrical heating




     Advantages
     • for doorways (up to 4 m)
     • stylish design
     • low noise level
     • corrosion-proof casing made from galvanized
     sheet steel and painted with white enamel
     • overheating protection
     • ease of assembly (vertical and horizontal)




                                                                               Air velocity profile

Recommended application
Stylish design and high effectiveness are combined in this new,     Speed control
powerful air curtain for large, luxurious entrances in hotel lob-   The three-speed fan is regulated by an external MP control
bies and trade centers. Portier Grand curtains are suitable for     panel (additional accessory). The air curtains can be connect-
doorways up to 4 m in height. ?The curtain has a stylish            ed to the HDGL door status sensor.
design from both sides and is an ideal solution for large
glass openings.                                                     Assembly
                                                                    The curtains can be installed both horizontally and vertically.
Construction                                                        The one exception is the PGL14 model, which must be
The durable construction (no plastic parts) is made entirely        installed horizontally. All air curtains are equipped with remov-
from corrosion-proof polished steel coated with a powder-paint      able side panels for ease of installation and servicing.
coating. Fan, motor, heating elements and control automation
are mounted inside a curved steel casing with a powder-paint-       Certificates
ed coating. The curtains are equipped with a electrical air-heat-   Certificate of Conformity of the Russian Federation,
ing element and are supplied in two standard dimensions, with       Ukraine, SEMKO and CE Standard.
different lengths.



Motor
The air curtains are equipped with low-noise crossflow fans
and an adjustable airflow grille.


50
                                                                                                             Portier Grand


                                                           Basic dimensions


                                                            410                            1020 / 1560
                                HW

                     445                         375


                                                             85
                                                            134




                                                             Specifications




                                                       PG0              PG9                 PGL0                  PGL14
 Length                                   mm           1020             1020                1560                  1560
 Power, heating                            kW          -                9                   -                     13.5
 Power, motor                               W          391              391                 575                   575
 Voltage                                     V         230~1            400~3N              230~1                 400~3N
 Current                                     A         1.7              14.4                2.5                   21.5
 Air consumption (low / high)            m3/h          1200/2400        1400/2300           2500/3900             2500/3900
 Temperature increase                       °C         -                19/11               -                     18/11
 Noise level                            dB(A)          52/68            52/68               60/71                 60/71
 Weight                                     kg         26               29                  39                    43,5
 Protection index                                      IP 23            IP23                IP23                  IP23
 Product identification number                         4637             4641                4639                  4643
 Price                                                 1203,0           1731,0              1677,0                2218,0




Accessories




MP Control panels,   SR thermostats,   HDGL sensor,    PGMBV panel,   PBH pendulum      PBS mounting kit, PGT, connecting   PGF removable
     p. 114              p. 117          p. 118           p. 124      hanging, p. 119       p. 119          kit p. 119      panels,p. 120

                                                                                                                                        51
Air curtains
  Portier Grand
Assembly                                                             the connection block, must be replaced by a panel with
Portier Grand air curtains are designed for stationary instal-       ventilation holes, supplied additionally with the curtain.
lation in a vertical (PG0, PGL0, PG9 models) or horizontal           Portier Grand curtains can be installed vertically at the side
(PG0, PG9, PGL0 and PGL14) manner above entrances                    of the doorway, creating a horizontal airflow. To avoid
and doorways up to 4 m in height. IP23 Protection index.             mounting the air curtain directly onto the floor, a special
The PG curtains are equipped with a low-noise crossflow              PGMBV vertical mounting kit must be ordered separately
fan and are meant for continuous operation. Electrical air-          (additional accessory). For high doorways, requiring the
heating elements are assembled in two groups and con-                curtains to be stacked in a column, a special PGT connect-
trolled with contactors. They are turned on and off by a             ing kit is supplied. The column must be mounted to the wall
switch on the MP control panel, and are automatically reg-           and the floor. To provide additional safety, a PGPG safety
ulated by an SR12 thermostat, in accordance with the heat-           grille can be installed on the inner side of the air curtain
ing load.                                                            (not supplied with the device).

Horizontal installation                                              Airflow control
Portier Grand is installed at least 120 mm away from the             The direction and velocity of the airflow can be regulated to
ceiling or any other obstruction, stopping the flow of air           suit the parameters of a given doorway.
over the device. There are no minimal distances to the sur-          The air-discharge grille can be easily adjusted by hand and
rounding walls. The air curtain is mounted on the wall or            must be facing outside the premises (5 - 10°) to achieve
ceiling using 4 M6 threaded holes at the top of the casing.          the best protection of the doorway. The angle of the air -
For the sake of convenience a special PBS wall mounting              discharge plane increases as the pressure and tempera-
kit can be ordered as an additional accessory.                       ture differentials between the premises and the outside
The air curtain can be suspended from the ceiling on                 increase, as well as with an increase of velocity of the wind
cables or chains with screw eyes. The device may also be             blowing into the doorway. The airflow velocity can be regu-
suspended on (M6) threaded bars, which are screwed                   lated by a three-position switch on the (MP 32 or MP 30)
directly into the threaded holes.                                    control panel. The velocity must reach 3 - 4 m/s at a height
A deflector mounted on both sides of the doorway can                 of 1 meter from the floor.
increase the effectiveness of the air curtain.

Vertical installation
Please note that of the air curtains with an electrical heating
element only PG9 can be mounted vertically. It is recom-
mended to carefully read the manual before PG9 assem-
bly.
The PGL14 curtain must be installed horizontally. PG0 and
PGL0 air curtains without heating elements can be installed
horizontally and vertically. During vertical installation, the
curtain side with the motor must be on top.
During the vertical installation of a PG9 air curtain with an
electrical heater, the panel, covering




  In case of vertical mounting, it is recommended to place a deflector on the
  other side for optimal efficiency and comfort.


                                                                                                             PGT




                                                               Use the PGMBV mounting panel to verti-
     A = min. 80 mm
                                                               cally mount the first PG/PGD curtain on to
     A + B = min. 120 mm                                       the floor and the PGT connecting kit to
                                                               mount the subsequent PG curtains in the
                                                                                                            PGMBV
                                                               column.


52
                                                                                                                                           Portier Grand
Electrical connection                                                                        similar cables. Cable glands used in the process must sat-
The curtain must be protected by a switch with a minimal                                     isfy the relevant safety requirements. Power cable and con-
contact gap                                                                                  trol cable have two different inlets in air curtains with electri-
of 3 mm.                                                                                     cal heating elements.
There are various ways to regulate the air flow velocity.
Cable connectors are easily accessible by removing one of
the outer panels.
The power should be supplied via S05W-U, A05W-R or




                                                                             Electric circuits

   PG9 (or PGL14) + MP32 control panel + SR12 thermostat + HDGL sensor

                                    MP32


                                                                                                       SR 12
                                                0                                                              HI    LO


                                                                                                                           °C



                                           1 1 2 3 4 4 5 6 6 7 7         8 9 10 10 11 11                   1 1 2 3 4 5 6 7 L L N



                                                                                                                                230V~

                    21   13

                    22   14
                                                                                                                               Air flow velocity (high / low) is
                 HDGL                                                                                                          controlled by a door sensor.
                                     400V3~                                                                                    High velocity with an open
                          230V~                                                                                                sensor, low with a closed sen-
                                                                                                                               sor.
                                                                                                    PG943
                              N L    L1 L2 L3        Tk Tk 0 1 2 4 5 6 7 8 9 10 11                  PGL1443




   PG0 (or PGL0) + MP30 control panel + HDGL gate sensor

                                                                        MP30



                                                                                     0




                                                230V~                          1 1 2 3 4 4 5 6 6 7 7

                                                        2
                                                        1
                                                                    A
                                                        5
                                                        4
                                                        3                A
                                                                    B
                                                RT 0-30
                                                                         B
                                                                                                                                        Gate sensor shuts the air
                                                                             230V~
                                                                    A                                                                   curtain on / off.
                                                          21   13

                                                          22   14   B
                                                                                                                    PG0 PGL0
                                                                             N L           Tk Tk 0 1 2 3 4 5 6      PGW PGLW
                                                    HDGL

                                                                                                                    PG0 PGL0
                                                                             N L           Tk Tk 0 1 2 3 4 5 6      PGW PGLW



                                                                                                                    PG0 PGL0
                                                                             N L           Tk Tk 0 1 2 3 4 5 6      PGW PGLW




                                                                                                                                                                    53
Air curtains
  Portier Grand W




                                                                                                                      Танген
                                                                                                                    циальный
                                                                                                                    вентилятор




                                                                                                                  Горизонтальный
                                                                                                                      монтаж




                                                                                                                    Вертикальный
                                                                                                                       монтаж




                                                                                                                     Водяной
                                                                                                                      нагрев




                                                                                                          м/с       м/с
      Advantages
      • for doorways (up to 4 m)
      • stylish design
      • low noise level
      • corrosion-proof casing made from galva-
      nized sheet steel and painted with white
      enamel
      • overheating protection
      • ease of assembly




                                                                              Air velocity profile


Recommended application                                            the HDGL door status sensor.
Stylish design and high effectiveness are combined in this new,
powerful air curtain with water heater for large, luxurious        Assembly
entrances in hotel lobbies and trade centers. Portier Grand cur-   The curtains can be installed both horizontally and vertically.
tains are suitable for doorways up to 4 m in height.               All air curtains are equipped with removable side panels for
                                                                   ease of installation and servicing. The maximum temperature of
Construction                                                       water in the curtains with a water-based heating element is 100
The durable construction (no plastic parts) is made entirely       °C.
from corrosion-proof polished steel coated with a powder-paint
coating. Fan, motor, heating elements and control automation       Certificates
are mounted inside a curved steel casing with a powder-paint-      Certificate of Conformity of the Russian Federation,
ed coating. The curtains are equipped with a water air-heating     Ukraine, SEMKO and CE Standard.
element and are supplied in two standard dimensions, with dif-
ferent lengths.

Motor
The air curtains are equipped with low-noise crossflow fans
and an adjustable airflow grille.
Speed control
A three-speed fan is regulated by an external MP30 control
panel for curtains without a heating element and with a water-
based heating element. The air curtains can be connected to

54
                                                                                                         Portier Grand W


                                                       Basic dimensions


                                                             410                             1020 / 1560
                                HW

                     445                         375


                                                              85
                                                             134




                                                              Specifications


                                                      PGW             PGLW                   PGWV                  PGLWV
 Length                                   mm           1020            1560                  1020                  1560
 Power, heating                            kW          see Table*)     see Table*)           see Table*)           see Table*)
 Power, motor                               W          320             552                   322                   564
 Voltage                                     V         230~1           230~1                 230~1                 230~1
 Current                                     A         1.39            2.4                   1.4                   2.45
 Air consumption (low / high)            m3/h          1000/2100       1700/3600             900/180               1300/2900
 Temperature increase                       °C         see Table*)     see Table*)           see Table*)           see Table*)
 Noise level                            dB(A)          52/67           52/66                 53/68                 54/69
 Weight                                     kg         31              52                    31                    52
 Protection index                                      IP23            IP23                  IP44                  IP44
 Product identification number                         4645            4647                  4632                  4634
 Price                                                 1703,0          2326,0                1758,0                2434,0




                                                                                        W - curtains with water-based air heater
                                                                                        V - vertical installation




Accessories




MP Control panels,   SR thermostats,   HDGL sensor,    PGMBV panel,   PBH pendulum       PBS mounting kit, PGT, connecting   PGF removable
     p. 114              p. 117          p. 118           p. 120      hanging, p. 119        p. 119          kit, p. 120     panels, p. 120


                                                                                                                                         55
Air curtains
  Portier Grand W

Assembly                                                            and horizontally. The heating element connects to the
Portier Grand air curtains are designed for stationary instal-      building’s water-based central heating system via DN20
lation in a vertical (PGDWV and PGDLWV) or horizontal               threaded connectors. The water supply could be regulated
(PGDVW, PGDLVW, PGDW and PGDLW) manner above                        with a FHW2RV water valve and a FHWACT valve actuator
the entrances and doorways up to 4 m in height.                     connected to the thermostat. Use FHW2RV20 for a single
The air is sucked in the upper part of the curtain and is           curtain and FHW2RV25 for two
blown out in a flat, high-velocity stream, creating a protec-       or more, connected in a shared water supply network. The
tive barrier of air across the doorway.                             water-based heating element is protected by a filter, which
                                                                    can be removed for cleaning purposes.
The PG curtains are equipped with a low-noise crossflow
fan and are meant for continuous operation. Electrical air-         Airflow control
heating elements are assembled in two groups and con-               The direction and velocity of the airflow can be regulated to
trolled with contactors. They are turned on and off by a            suit the parameters of a given doorway.
switch on the MP control panel or are automatically regulat-        The air-discharge grille can be easily adjusted by hand and
ed by an SR12 thermostat, in accordance with the heating            must be facing outside the premises (5 - 10°) to achieve
load.                                                               the best protection of the doorway. The angle of the air-dis-
                                                                    charge plane should increase as the pressure and temper-
Horizontal installation                                             ature differentials between the premises and the outside
Portier Grand is installed at least 120 mm away from the            increase, as well as with an increase of velocity of the wind
ceiling or any other obstruction, stopping the flow of air          blowing into the doorway. The airflow velocity can be regu-
over the device. There are no minimal distances to the sur-         lated by a three-position switch on the (MP 32 or MP 30)
rounding walls.                                                     control panel. The velocity must reach 3 - 4 m/s at a height
The air curtain is mounted on the wall or ceiling using 4 M6        of 1 meter from the floor.
threaded holes at the top of the casing. For the sake of
convenience a special PBS wall mounting kit can be
ordered as an additional accessory
The air curtain can be suspended from the ceiling on
cables or chains with screw eyes. The device may also be
suspended on (M6) threaded bars, which are screwed
directly into the threaded holes.
A deflector mounted on both sides of the doorway can
increase the effectiveness of the air curtain.

Vertical installation
Please note that of the air curtains with a water-based heat-
ing element only PGDVW or PGLVW can be mounted verti-
cally! The design of the model allows water to be supplied
both from to the top and bottom of the air curtain. To avoid
placing the air curtain directly on the floor, a special vertical
wall mounting kit for PGMBV must be ordered (additional
accessory). For high doorways, requiring the curtains to be
stacked in a column, a special PGT connecting kit is sup-
plied. The column must be mounted to the wall and the
floor.
To provide additional safety, a PGPG safety grille can be
installed on the inner side of the air curtain (additional
accessory).

Electrical connection
The air curtain power supply must be connected by quali-
fied personnel in accordance with the stipulated rules and
guidelines. The curtain must be protected with an all-pole
switch, with a minimum contact gap of 3 mm.
There are various ways to regulate the air flow velocity.
Cable connectors are easily accessible by removing one of
the outer panels. The power should be supplied via S05W-
U, A05W-R or similar cables. Cable glands used in the
process must satisfy the relevant safety requirements.

Water connection
PGW and PGLW have a water-based heating element,
meant for horizontal installation. PGVW and PGLVW have
heating elements, which could be installed both vertically




56
                                                                                                      Portier Grand W


                                                        Assembly




     In case of vertical mounting, it is recommended to place a deflector on the
     other side for optimal efficiency and comfort.



                                                                                                         PGT




                                                             Use the PGMBV mounting panel to
                                                                                                        PGMBV
        A = min. 80 mm                                       vertically mount the first PG/PGD cur-
        A + B = min. 120 mm                                  tain on to the floor and the PGT con-
                                                             necting kit to mount the subsequent
                                                             PG curtains in the column.




Accessories for water connection




FHWACT - actua-       FHW2RV         FHWAV           FHWSV stopping
  tor, p. 118           Control valves, p. 118         valve, p. 118

                                                                                                                    57
Air curtains
 Portier Grand W

                                Pressure differential in the PGW/PGLW curtain’s water circuit
                                                                                        Water consumption
                                                                                        [m33/h]
        Pressure drop [kPa]




                                                                                                                  Pressure drop [bar]
                                                                                              Water consumption




                                        PGW/PGDW and PGWV/PGDWV Series
                                     Heating power and increase of air temperature

                                   Supply         95/70            80/60         70/50
                    ti°C             air      Δti°C QkW        Δti°C QkW       Δti°C QkW
                    0                 1        49.2   17.7     41.6   15.0      35.3   12.8
                                      2        45.1   21.2     38.2   17.9      32.4   15.2
                                      3        38.5   27.8     32.6   23.5      27.7   20.0
                    +10               1        43.6   15.2     35.9   12.5     29.6    10.3
                                      2        40.0   18.1     33.0   14.9      27.2   12.3
                                      3        34.9   23.8     28.2   19.6      23.2   16.1
                    +15               1        40.7   13.9     33.0   11.3     26.7     9.1
                                      2        37.4   16.6     30.3   13.5      24.4   10.9
                                      3        32.0   21.9     26.0   17.7      20.8   14.3
                    +20               1        37.9   12.7     30.1   10.1     23.7     8.0
                                      2        34.7   15.2     27.6   12.1      21.7    9.5
                                      3        29.7   20.0     23.6   15.9     18.15   12.4
                                                                                                   ti°C = Air temperature at the inlet
                                                                                                   Δti°C = Increase of air temperature
                                      PGLW/PGDLW and PGLWV/PGDLWV Series                           Q = Heating power
                                      Heating power and increase of air temperature
                                   Supply        95/70             80/60          70/50
                         ti°C        air     Δti°C QkW         Δti°C QkW       Δti°C QkW
                         0            1       46.2    33.3     39.1   28.2      33.2    24.0
                                      2       43.4    37.6     36.7   31.8      31.2    27.0
                                      3       39.0    45.1     32.7   37.7      28.0    32.3
                         10           1       41.0    28.5     33.8   23.5      27.9    19.4
                                      2       38.5    32.1     31.7   26.5      26.1    21.8
                                      3       34.6    38.6     28.5   31.8      23.5    26.1
                         15           1       38.3    26.2     31.1   21.2      25.1    17.2
                                      2       36.0    29.5     29.2   24.0      23.6    19.3
                                      3       32.4    35.4     26.3   28.7      21.1    23.1
                         20           1       35.6    23.9     28.3   19.0      22.3    15.0
                                      2       33.4    27.0     26.6   21.5      20.9    16.9
                                      3       30.1    32.4     23.9   25.7      18.8    20.2



58
                                                                                                                                      Portier Grand W


                                                                                   Electric circuits



PGW (or PGLW) + MP30 control                                                                           PGW (or PGLW) + MP30 control panel
panel + HDGL gate sensor                                                                               + RT O - 30 + FHWACT actuator


                        MP30                                                                                                     MP30



                                     0                                                                                                       0




230V~                           1 1 2 3 4 4 5 6 6 7 7                                                                                   1 1 2 3 4 4 5 6 6 7 7

        2                                                                                                            2
        1
                    A
        5                                                                                                            1
        4
        3                A
                                                                                                                     5
                    B                                                                                                4
RT 0-30                                                                                                              3
                         B


                    A
          21   13                                                                                          RT 0-30

          22   14   B
                                                                      PG0 PGL0
                             N L             Tk 0 1   3 4   6         PGW PGLW                                                          V~
  HDGL

                                                                      PG0 PGL0
                             N L             Tk 0 1   3 4   6         PGW PGLW                           FHWACT                                         Tk 0   3 4 5 6
                                                                                                                                      N L

                                                                                                                                                                  PGW PGLW
                                                                      PG0 PGL0                         FHW2RV20/25
                             N L             Tk 0 1   3 4 5 6         PGW PGLW




PGW (or PGLW) + MP30 control panel+ RT O - 30 + FHWACT actuator + SR12 + HDGL gate sensor



                                                                            MP30



                                                                                       0                                 SR 12
                                                                                                                                 HI     LO

                                                                 21    13                                                                        °C

                                                                 22    14          1 1 2 3 4 4 5 6 6 7 7    8 9 10
                                                                                                                             1 1 2 3 4 5 6 7 L L N
                                         2                  HDGL
                                         1
                                         5
                                                                                                                                                      230V~
                                         4
                                         3



                               RT 0-30




                             FHWACT                             N L                0 1 2 3 4 5 6

                                                                                              PGW PGLW
                             FHW2RV20/25




                                                                                                                                                                         59
Air curtains
  Portier Grand Design




                                                                                                                             Танген
                                                                                                                           циальный
                                                                                                                           вентилятор




                                                                                                                       Горизонтальный
                                                                                                                           монтаж




                                                                                                                          Вертикальный
                                                                                                                             монтаж




                                                                                                                          Electrical heating




      Advantages                                                                                            PGD    PGDL

      • for doorways (up to 4 m)                                                   м
      • stylish design
                                                                                       м
      • low noise level
                                                                                   м
      • corrosion-proof steel casing made from gal-
      vanized sheet steel                                                              м
      • overheating protection                                                     м
      • ease of assembly (vertical and horizontal)
                                                                                       м


                                                                                       м


                                                                            Air velocity profile


Recommended application
Stylish design and high effectiveness are combined in this new,     Assembly
powerful air curtain for large, luxurious entrances in hotel lob-   The curtains can be installed both horizontally and vertically.
bies and trade centers. Portier Grand Design - a stylish model      The one exception is the PGDL14 model, which must be
of Portier Grand curtain is suitable for doorways up to 4 m in      installed horizontally. All air curtains are equipped with remov-
height. An ideal solution for glass openings.                       able side panels for ease of installation and servicing.

Construction                                                        Certificates
The durable construction (no plastic parts) is made entirely        Certificate of Conformity of the Russian Federation,
from corrosion-proof polished steel. Fan, motor, heating ele-       Ukraine, SEMKO and CE Standard.
ments and control automation are mounted inside a curved
steel casing. The curtains are equipped with a electrical air-
heating element and are supplied in two standard dimensions,
with different lengths.

Motor
The air curtains are equipped with low-noise crossflow fans
and an adjustable airflow grille.
Speed control
The three-speed fan is regulated by an external MP control
panel (additional accessory). The air curtains can be connect-
ed to the HDGL door status sensor.


60
                                                                                                 Portier Grand Design


                                                            Basic dimensions


                                                             410                                 1020 / 1560
                               HW

                     445                          375


                                                              85
                                                              134




                                                              Specifications



                                                        PGD0             PGD9                PGDL0                 PGDL14
 Length                                    mm           1020             1020                1560                  1560
 Power, heating                             kW          -                9                   -                     13.5
 Power, motor                                W          391              391                 575                   575
 Voltage                                      V         230~1            400~3N              230~1                 400~3N
 Current                                      A         1.7              14.4                2.5                   21.5
 Air consumption (low / high)             m3/h          1200/2400        1400/2300           2500/3900             2500/3900
 Temperature increase                        °C         -                19/11               -                     18/11
 Noise level                             dB(A)          52/68            52/68               60/71                 60/71
 Weight                                      kg         25,5             28,5                38,5                  43,5
 Protection index                                       IP 23            IP23                IP23                  IP23
 Product identification number                          9537             9540                9538                  9592
 Price                                                  1374,0           1902,0              1906,0                2446,0




Accessories




MP Control panels,    SR thermostats,   HDGL sensor,    PGMBV panel,   PBH pendulum      PBS mounting kit, PGT, connecting   PGF removable
     p. 114               p. 117          p. 118           p. 120      hanging, p. 119       p. 119          kit, p. 120      panels,p. 120


                                                                                                                                         61
Air curtains
  Portier Grand Design
Assembly                                                             ventilation holes, supplied additionally with the curtain.
Portier Grand Design air curtains are designed for station-          To avoid mounting the air curtain directly onto the floor, a
ary installation in a vertical (PGD0, PGD9, PGDL0 models)            special PGMBV vertical mounting kit must be ordered sep-
or horizontal (PGD0, PGD9, PGDL0 and PGDL14) manner                  arately (additional accessory). For high doorways, requiring
above entrances and doorways up to 4 m in height.                    the curtains to be stacked in a column, a special PGT con-
The PGD curtains are equipped with a low-noise crossflow             necting kit is supplied. The column must be reliably
fan and are meant for continuous operation. Electrical air-          secured to the wall and the floor. To provide additional
heating elements are assembled in two groups and con-                safety, a PGPG safety grille can be installed on the inner
trolled with contactors. They are turned on and off by a             side of the air curtain (not supplied with the device).
switch on the MP control panel or are automatically regulat-
ed by an SR12 thermostat, in accordance with the heating             Airflow control
load.                                                                The direction and velocity of the airflow is regulated to suit
                                                                     the parameters of a given gateway.
Horizontal installation                                              The air-discharge grille can be easily adjusted by hand and
Portier Grand Design is installed at least 120 mm away               must be facing outside the premises (5 - 10°) to achieve
from the ceiling or any other obstruction, stopping the flow         the best protection of the doorway. The angle of the air-dis-
of air over the device. There are no minimal distances to            charge plane should increase as the pressure and temper-
the surrounding walls. The air curtain is mounted on the             ature differentials between the premises and the outside
wall or ceiling using 4 M6 threaded holes at the top of the          increase, as well as with an increase of velocity of the wind
casing. For the sake of convenience a special PBS wall               blowing into the doorway. The airflow velocity can be regu-
mounting kit can be ordered as an additional accessory.              lated by a three-position switch on the (MP 32 or MP 30)
The air curtain can be suspended from the ceiling on                 control panel. The velocity must reach 3 - 4 m/s at a height
cables or chains with screw eyes. The device may also be             of 1 meter from the floor.
suspended on (M6) threaded bars, which are screwed
directly into the threaded holes.
A deflector mounted on both sides of the doorway can
increase the effectiveness of the air curtain.

Vertical installation
Please note that of the air curtains with an electrical heating
element, only PGD9 can be mounted vertically. The
PGDL14 curtain must be installed horizontally. PGD0 and
PGDL0 air curtains without heating elements can be
installed horizontally and vertically.
During vertical installation, the curtain side with the motor
must be on top.
During the vertical installation of a PG9 air curtain with an
electrical heater, the panel, covering
the connection block, must be replaced by a panel with




  In case of vertical mounting, it is recommended to place a deflector on the
  other side for optimal efficiency and comfort.


                                                                                                             PGT




                                                               Use the PGMBV mounting panel to verti-
                                                               cally mount the first PG/PGD curtain on to
     A = min. 80 mm
     A + B = min. 120 mm                                       the floor and the PGT connecting kit to
                                                               mount the subsequent PG curtains in the
                                                                                                            PGMBV
                                                               column.


62
                                                                                                                      Portier Grand Design
Electrical connection                                                                       similar cables. Cable glands used in the process must sat-
The curtain must be protected by a switch with a minimal                                    isfy the relevant safety requirements. Power cable and con-
contact gap                                                                                 trol cable have two different inlets in air curtains with electri-
of 3 mm.                                                                                    cal heating elements.
There are various ways to regulate the air flow velocity.
Cable connectors are easily accessible by removing one of
the outer panels.
The power should be supplied via S05W-U, A05W-R or



                                                                           Electric circuits

   PGD9 (or PGDL 14) + MP32 control panel + SR12 thermostat + HDGL sensor


                                      MP32


                                                                                                       SR 12
                                                  0                                                            HI   LO


                                                                                                                           °C



                                             1 1 2 3 4 4 5 6 6 7 7        8 9 10 10 11 11                  1 1 2 3 4 5 6 7 L L N



                                                                                                                                230V~

                      21   13

                      22   14
                                                                                                                               Air flow velocity (high / low) is
                  HDGL                                                                                                         controlled by a door sensor.
                                       400V3~                                                                                  High velocity with an open
                            230V~
                                                                                                                               sensor, low with a closed sen-
                                                                                                                               sor.
                                                                                                     PG943
                                N L    L1 L2 L3        Tk Tk 0 1 2 4 5 6 7 8 9 10 11                 PGL1443




   PGD0 (or PGDL 0) + MP30 control panel + HDGL gate sensor




                                                                          MP30



                                                                                       0




                                                  230V~                          1 1 2 3 4 4 5 6 6 7 7

                                                          2
                                                          1
                                                                      A
                                                          5
                                                          4
                                                          3                A
                                                                      B
                                                  RT 0-30
                                                                           B
                                                                                                                                        Gate sensor shuts the air
                                                                               230V~
                                                                      A                                                                 curtain on / off.
                                                            21   13

                                                            22   14   B
                                                                                                                    PG0 PGL0
                                                                               N L          Tk Tk 0 1 2 3 4 5 6     PGW PGLW
                                                      HDGL

                                                                                                                    PG0 PGL0
                                                                               N L          Tk Tk 0 1 2 3 4 5 6     PGW PGLW



                                                                                                                    PG0 PGL0
                                                                               N L          Tk Tk 0 1 2 3 4 5 6     PGW PGLW




                                                                                                                                                                    63
Air curtains
  Portier Grand Design W




                                                                                                                          Танген
                                                                                                                        циальный
                                                                                                                        вентилятор




                                                                                                                       Горизонтальный
                                                                                                                           монтаж




                                                                                                                        Вертикальный
                                                                                                                           монтаж




                                                                                                                         Водяной
                                                                                                                          нагрев




     Advantages                                                                    м
     • for doorways (up to 4 m)
                                                                                       м
     • stylish design
     • low noise level                                                             м
     • corrosion-proof steel casing made from gal-                                     м
     vanized sheet steel                                                           м
     • overheating protection
     • ease of assembly
                                                                                       м


                                                                                       м


                                                                               Air velocity profile

Recommended application
Stylish design and high effectiveness are combined in this new,     Speed control
powerful air curtain for large, luxurious entrances in hotel lob-   The three-speed fan is regulated by an external MP control
bies and trade centers. Portier Grand Design W curtains are         panel (additional accessory). A single control panel can regu-
suitable for doorways up to 4 m in height. The curtain has a        late up to four Portier curtains. The air curtains can be connect-
stylish design from both sides and is an ideal solution for         ed to the HDGL door status sensor.
glass openings.
                                                                    Assembly
Construction                                                        The curtains can be installed both horizontally and vertically. All
The durable construction (no plastic parts) is made entirely        air curtains are equipped with removable side panels for ease
from corrosion-proof polished steel. Fan, motor, heating ele-       of installation and servicing. The maximum temperature of
ments and control automation are mounted inside a curved            water in the curtains with a water-based heating element is 100
steel casing. The curtains are equipped with a water air-heating    °C.
element and are supplied in two standard dimensions, with dif-
ferent lengths.                                                     Certificates
                                                                    Certificate of Conformity of the Russian Federation,
                                                                    Ukraine, SEMKO and CE Standard.


Motor
The air curtains are equipped with low-noise crossflow fans
and an adjustable airflow grille.


64
                                                                                         Portier Grand Design W

                                                      Basic dimensions


                                                        410                               1020 / 1560
                              HW

                     445                      375


                                                           85
                                                        134




                                                             Specifications



                                                      PGDW           PGDLW                  PGDWV                 PGDLWV
 Length                                   mm          1020            1560                  1020                  1560
 Power, heating                            kW         see Table*)     see Table*)           see Table*)           see Table*)
 Power, motor                               W         320             552                   322                   564
 Voltage                                     V        230~1           230~1                 230~1                 230~1
 Current                                     A        1.39            2.4                   1.4                   2.45
 Air consumption (low / high)            m3/h         1000/2100       1700/3600             900/180               1300/2900
 Temperature increase                       °C        see Table*)     see Table*)           see Table*)           see Table*)
 Noise level                            dB(A)         53/67           52/66                 47/64                 54/64
 Weight                                     kg        31              52                    31                    52
 Protection index                                     IP23            IP23                  IP23                  IP23
 Product identification number                        9626            9630                  9634                  9653
 Price                                                1873,0          2555,0                1928,0                2663,0




                                                                                       W - curtains with water-based air heater
                                                                                       V - vertical installation




Accessories




MP Control panels,   SR thermostats,   HDGL sensor,   PGMBV panel,   PBH pendulum       PBS mounting kit, PGT, connecting   PGF removable
     p. 114              p. 117          p. 118          p. 120      hanging, p. 119        p. 119          kit, p. 120      panels, p. 120


                                                                                                                                        65
Air curtains
  Portier Grand Design W

Assembly                                                            FHW2RV water valve and a FHWACT valve actuator con-
Portier Grand air curtains are designed for stationary instal-      nected to the thermostat. Use FHW2RV20 for a single cur-
lation in a vertical (PGDWV and PGDLWV) or horizontal               tain and FHW2RV25 for two
(PGDW and PGDLW) manner above the entrances and                     or more, connected in a shared water supply network. The
doorways up to 4 m in height.                                       water-based heating element is protected by a filter, which
The air is sucked in the upper part of the curtain and is           can be removed for cleaning purposes.
blown out in a flat, high-velocity stream, creating a protec-
tive barrier of air across the doorway.                             Airflow control
                                                                    The direction and velocity of the airflow can be regulated to
The PGDW curtains are equipped with a low-noise cross-              suit the parameters of a given doorway.
flow fan and are meant for continuous operation. The                The air-discharge grille can be easily adjusted by hand and
water-based air-heating elements are turned on and off by           must be facing outside the premises (5 - 10°) to achieve
a switch on the MP control panel or they are automatically          the best protection of the doorway. The angle of the air-dis-
regulated by an SR12 thermostat, in accordance with the             charge plane should increase as the pressure and temper-
heating load.                                                       ature differentials between the premises and the outside
                                                                    increase, as well as with an increase of velocity of the wind
Horizontal installation                                             blowing into the doorway.
Portier Grand Design W is installed at least 120 mm away
from the ceiling or any other obstruction, stopping the flow        To regulate the Portier Grand Design W air curtain with a
of air over the device. There are no minimal distances to           water-based heating element, the following remote control
the surrounding walls.                                              panels are used: MP20 and MP30 or MP0-I, which is built
The air curtain is mounted on the wall or ceiling using 4 M6        into the casing.
threaded holes at the top of the casing. For the sake of            The air-flow velocity can be regulated by a three-position
convenience a special PBS wall mounting kit can be                  switch at the MP control panel. The velocity must reach 3 -
ordered as an additional accessory.                                 4 m/s at a height of 1 meter from the floor.
The air curtain can be suspended from the ceiling on
cables or chains with screw eyes. The device may also be
suspended on (M6) threaded bars, which are screwed
directly into the threaded holes.
A deflector mounted on both sides of the doorway can
increase the effectiveness of the air curtain.

Vertical installation
Please note that of the air curtains with a water-based heat-
ing element only PGDVW or PGLVW can be mounted verti-
cally! The design of the model allows water to be supplied
both from to the top and bottom of the air curtain. To avoid
placing the air curtain directly on the floor, a special vertical
wall mounting kit for PGMBV must be ordered (additional
accessory). For high doorways, requiring the curtains to be
stacked in a column, a special PGT connecting kit is sup-
plied. The column must be mounted to the wall and the
floor.
To provide additional safety, a PGPG safety grille can be
installed on the inner side of the air curtain (additional
accessory).

Electrical connection
The air curtain power supply must be connected by quali-
fied personnel in accordance with the stipulated rules and
guidelines. The curtain must be protected with an all-pole
switch, with a minimum contact gap of 3 mm.
There are various ways to regulate the air flow velocity.
Cable connectors are easily accessible by removing one of
the outer panels. The power should be supplied via S05W-
U, A05W-R or similar cables. Cable glands used in the
process must satisfy the relevant safety requirements.

Water connection
PGDW and PGDLW have a water-based heating element,
meant for horizontal installation. PGVW and PGLVW have
heating elements, which can be installed both vertically and
horizontally. The heating element connects to the building’s
water-based central heating system via DN20 threaded
connectors. The water supply could be regulated with a


66
                                                                                       Portier Grand Design W


                                                        Assembly




     In case of vertical mounting, it is recommended to place a deflector on the
     other side for optimal efficiency and comfort.



                                                                                                       PGT




                                                             Use the PGMBV mounting panel to
                                                                                                      PGMBV
       A = min. 80 mm
                                                             vertically mount the first PG/PGD cur-
       A + B = min. 120 mm                                   tain on to the floor and the PGT con-
                                                             necting kit to mount the subsequent
                                                             PG curtains in the column.




Accessories for water connection




FHWACT - actua-       FHW2RV         FHWAV           FHWSV stopping
  tor, p. 118           Control valves, p. 118         valve, p. 118

                                                                                                              67
Air curtains
 Portier Grand Design W

                              Pressure differential in the PGDW/PGDLW curtain’s water circuit
                                                                                       Water consumption
                                                                                       [m33/h]
        Pressure drop [kPa]




                                                                                                                 Pressure drop [bar]
                                                                                             Water consumption




                                              PGDW and PGDVW Series
                                    Heating power and increase of air temperature

                                   Supply        95/70            80/60         70/50
                    ti°C             air     Δti°C QkW        Δti°C QkW       Δti°C QkW
                    0                1        49.2   17.7     41.6   15.0     35.3    12.8
                                     2        45.1   21.2     38.2   17.9     32.4    15.2
                                     3        38.5   27.8     32.6   23.5     28.2    19.3
                    +10              1        43.6   15.2     35.9   12.5     27.7    20.0
                                     2        40.0   18.1     33.0   14.9     27.2    12.3
                                     3        34.9   23.8     28.2   19.6     23.2    16.1
                    +15              1        40.7   13.9     33.0   11.3     26.7     9.1
                                     2        37.4   16.6     30.3   13.5     24.4    10.9
                                     3        32.0   21.9     26.0   17.7     20.8    14.3
                    +20              1        37.9   12.7     30.1   10.1     23.7     8.0
                                     2        34.7   15.2     27.6   12.1     21.7     9.5
                                     3        29.7   20.0     23.6   15.9     18.5    12.4
                                                                                                  ti°C = Air temperature at the inlet
                                                                                                  Δti°C = Increase of air temperature
                                             PGDLW and PGDLWV Series                              Q = Heating power
                                     Heating power and increase of air temperature
                                  Supply        95/70             80/60          70/50
                         ti°C       air     Δti°C QkW         Δti°C QkW       Δti°C QkW
                         0           1       46.2    33.3     39.1   28.2      33.2    24.0
                                     2       43.4    37.6     36.7   31.8      31.2    27.0
                                     3       39.0    45.1     32.7   37.7      28.0    32.3
                         10          1       41.0    28.5     33.8   23.5      27.9    19.4
                                     2       38.5    32.1     31.7   26.5      26.1    21.8
                                     3       34.6    38.6     28.5   31.8      23.5    26.1
                         15          1       38.3    26.2     31.1   21.2      25.1    17.2
                                     2       36.0    29.5     29.2   24.0      23.6    19.3
                                     3       32.4    35.4     26.3   28.7      21.1    23.1
                         20          1       35.6    23.9     28.3   19.0      22.3    15.0
                                     2       33.4    27.0     26.6   21.5      20.9    16.9
                                     3       30.1    32.4     23.9   25.7      18.8    20.2



68
                                                                                                                         Portier Grand Design W



                                                                                   Electric circuits



PGDW (or PGDLW) + MP30 control                                                                             PGDW (or PGDLW) + MP30 control
panel + HDGL gate sensor                                                                                   panel + RTO 30 + FHWACT actuator


                        MP30
                                                                                                                                    MP30


                                     0
                                                                                                                                                0



230V~                           1 1 2 3 4 4 5 6 6 7 7
                                                                                                                                           1 1 2 3 4 4 5 6 6 7 7
        2
        1
                    A
        5                                                                                                            2
        4
        3                A                                                                                           1
                    B                                                                                                5
RT 0-30                                                                                                              4
                         B
                                                                                                                     3
                    A
          21   13

                                                                                                           RT 0-30
          22   14   B
                                                                      PG0 PGL0
                             N L             Tk 0 1   3 4   6         PGW PGLW
  HDGL                                                                                                                                     V~
                                                                      PG0 PGL0
                             N L             Tk 0 1   3 4   6         PGW PGLW

                                                                                                         FHWACT                          N L               Tk 0   3 4 5 6
                                                                      PG0 PGL0
                             N L             Tk 0 1   3 4 5 6         PGW PGLW                                                                                       PGW PGLW
                                                                                                       FHW2RV20/25




PGDW (or PGDLW) + MP30 control panel + RTO 30 + FHEACT actuator + SR12 + HDGL gate sensor




                                                                            MP30



                                                                                       0                                    SR 12
                                                                                                                                    HI     LO

                                                                 21    13                                                                           °C

                                                                 22    14          1 1 2 3 4 4 5 6 6 7 7    8 9 10
                                                                                                                                1 1 2 3 4 5 6 7 L L N
                                         2                  HDGL
                                         1
                                         5
                                                                                                                                                         230V~
                                         4
                                         3



                               RT 0-30




                             FHWACT                             N L                0 1 2 3 4 5 6

                                                                                              PGW PGLW
                             FHW2RV20/25




                                                                                                                                                                            69
                                                               Industrial series
                                                               To protect doorways higher than 3.5 m, air cur-
                                                               tains of HD, HF and MTV series are used.
                                                               In premises with high standards of interior design
                                                               it is recommended to use Portier Grand models,
                                                               presented on pages 55 - 74 of this catalogue.

                                                               Curtains of the HD and HF series can be mount-
                                                               ed into a false ceiling.

                                                               Curtains in HD, HF and MTV series have a wide
                                                               variety of uses:
                                                               - on gateways of industrial facilities
                                                               - on warehouses and logistics terminals
                                                               - on administrative buildings
                                                               - on entrances to trade centers, supermarkets,
  HDW - an example of installation into a false ceiling H&M    entertainment facilities and others
  Shopping center (Stockholm, Sweden)




 HF - factory production line, Sweden




HD - an example of a vertical installation. Reliable protec-
tion of warehouses. KOP Hypermarket (Yekaterinburg,
Russia)

70
Energy-saving
Systemair curtains enable you to significantly cut
heat loses on the premises, thus reducing the
heating and cooling expenses.
Remember – the bigger the gateway, the bigger
the energy saving!
The payoff period of our curtains is 2 - 3 years
and after that they can help you save energy for
many years to come.

Systemair’s many years of experience and the
Swedish quality of the manufactured devices
minimize operating costs when using our cur-
tains.

 On premises with a limited power supply, it is
recommended to use Systemair curtains with a         MTV - an example of a horizontal installation. Garage gates
water-based air-heating element.

Not only does protection of doorways with
Systemair curtains lower your energy costs, but it
also positively influences the working mood of
your employees and increases the sanitary pro-
tection of the premises.




                                                     MTV - protection of gates of car-care centers and car-washes




                                                     MTV - the perfect solution for warehouses and industrial facil-
                                                     ities. Warehouse gate, Systemair, Sweden.



                                                                                                                 71
Air curtains
    HD




                                                                                                                   Горизонтальный
                                                                                                                       монтаж




                                                                                                                       Вертикальный
                                                                                                                          монтаж




                                                                                                                   Electrical heating




                                                                                                            HD / HDL
     Advantages

     • for doorways (up to 3.5 m)
     • space-saving design
     • corrosion-proof steel casing made from gal-
     vanized sheet steel
     • overheating protection
     • air discharge plane can be displaced under
     the required angle
     • ease of installation (both horizontal and verti-
     cal)


                                                                           Air velocity profile

Recommended application                                         Automatics must be ordered separately. The HDR4 airflow
HD is a powerful air curtain, with or without an electrical     velocity controller can regulate the operation of up to 14
heating element, which is meant for protection of doorways      motors. The HDEV power controller regulates the electrical
in shopping malls, warehouse facilities etc. The air curtains   heating. The HDGL door status sensor may be connected
of this series can be used to dehumidify the area or as a       to an HDEV controller (with on / off positions) or an HDR42
main heating source in medium-sized industrial premises.        controller (with high / low positions), in order to regulate the
Due to the high power of HD curtains, the models without a      airflow when the door opens and closes. The HDEV regula-
heating element can be used to protect doorways of refrig-      tor may be connected to an SR122 thermostat.
erator rooms and air-conditioned facilities.
HD curtains are recommended for doorways 2.5 - 3.5 m in         Assembly
height.                                                         The curtains can be installed both horizontally and vertically.
.                                                               Installation into a false ceiling is also possible.
Construction
Design. Fans and heating elements (if they are included in      Certificates
the design) are mounted inside a corrosion-proof steel cas-     Certificate of Conformity of the Russian Federation,
ing. Depending on the HDW’s standard dimensions, it can         Ukraine, SEMKO and CE Standard
have 2 or 3 centrifugal fans fitted. Curtains are supplied in
two standard sizes, with different lengths.

Motor
HD air curtains are equipped with a powerful high-pressure
centrifugal fan.
Speed control

72
                                                                                                                        HD

                                                      Basic dimensions




                                                             Specifications


                                                      HD0                 HD8                 HDLO            HD12
 Length                                  mm           1000                1000                1700            1700
 Power, heating                           kW          -                   8                   -               12
 Power capacity, motors                    W          2 x 184             2 x 184             3 x 184         3 x 184
 Voltage                                    V         230 1~              400 3~              230 1~          400 3~
 Current                                    A         1.6                 11.9                2.4             17.7
 Air consumption (low / high)           m3/h          900/1800            900/1800            1300/2700       1300/2700
 Temperature increase                      °C         -                   27/13               -               27/13
 Noise level                           dB(A)          44/62               44/62               45/63           45/63
 Weight                                    kg         39                  44                  57              64
 Protection level                                     IP24                IP24                IP24            IP24
 Product identification number                        3053                3060                3057            3170
 Price                                  Euro          1316,0              1893,0              1836,0          2425,0




Accessories




HDR speed con-    HDEV power con-   SR thermostats,   HDGL sensor,   HDS mounting      An example of an HD air curtain assem-
  trols, p. 114     trols, p. 115       p. 117          p. 118       bracket, p. 119   bly in a false ceiling.

                                                                                                                           73
Air curtains
  HD
Assembly                                                          placement angle is up to 15°.
HD air curtains are designed to protect doorways and              The angle of the air-discharge plane should increase as the
gates 2.5 - 3.5 m in height. HD models can be supplied            pressure and temperature differentials between the premis-
with heating elements (HD8 and HD12) or without them              es and the outside increase, as well as with an increase of
(HD0 and HD0L).                                                   velocity of the wind blowing into the doorway. The optimal
Mounting consoles allow the airflow plane to be shifted in        effectiveness is reached when both sides of the doorframe
the necessary direction, depending on the aerial load on          are screened. When air curtains are installed over the
one or other side of the gate. The higher the load caused         entrance to refrigerator rooms, they are mounted on the
by wind, pressure and temperature differentials, the greater      warm side and have a 0 - 10° tilt angle towards the warmer
the displacement angle of the airflow plane of the curtain        side of the room.
should be towards the outside.                                    The air flow velocity can be regulated with a fan speed
                                                                  HDR4 control panel, which is supplied separately and con-
Horizontal installation                                           trols up to 7 short (2 fans) or 4 long (3 fans) air curtains.
The air curtain is usually mounted inside the premises,           Curtains with electric heating elements operate in 3 power
above the gateway, as close as possible to the horizontal         modes (0, Ѕ and full power), which are selected on the
axis of the entryway. The blow out aperture of the curtain        HDEV control panel and are regulated by a 2-step SR122
must be as close as possible to the entryway. If the air cur-     thermostat. A single HDEV power control panel can regu-
tain is meant to protect a refrigerator room, it should be        late up to 7 long air curtains.
mounted on the warm side of the premises.
The devices must be hung close to one another, to avoid
gaps in the airflows. A mounting gap of 50 mm is required
between the curtains, to tighten the bolts holding the con-
sole.
The console is mounted on M10 bolts in the central holes
of the console and on the sides of the curtain. The neces-
sary curtain inclination angle is fixed with M10 bolts in the
respective holes of the console and the curtain. It is neces-
sary to observe the minimal distances and take care not to
mount the device immediately above a power socket.

Vertical installation
In case there is not enough space above the gates for a
horizontal positioning, the air curtains are mounted beside
the gate in the column, creating a continuous airflow along
the entire height of the gateway. The curtains are fixed to
the floor and each other using HDS fittings. The curtains
are mounted vertically inside the premises, with the blowout                                          The mounting con-
aperture being as close as possible to the edge and hori-                                             soles are included in
zontal axis of the gateway. For two curtains installed on top                                         the shipment.
of each other, two HDS fitting sets must be ordered, each
in turn consisting of two parts.
The outer part is attached to the floor (or the top end of the
lower curtain with M10 bolts) by anchor bolts inserted in the
central and semi-circular holes, while the inner part of the
fitting is attached to the end of the lower and upper cur-                                            The HDS mounting
tains. Prior to tightening the anchor bolts in the floor, place                                       brackets (additional
the HDS at the correct angle to the gateway plane and                                                 accessory) can make
tighten the nuts. The fitting piece is fixed with 3 M10 bolts.                                        the installation quick
The maximum height of the column must not exceed 3.5                                                  and easy.
m.
At the top end of the top curtain a console is installed to
attach the column to the wall. The HDR4 fan speed control
panel can be installed in any convenient location. When
mounting curtains with an electrical heating element, the
HDEV power control panel is installed next to HDR4, while
the thermostat (SR122 for example) is placed in a location
where it will most accurately measure the air temperature
changes at the gate area.
                                                                                                      For a single curtain,
                                                                                                      installed in a vertical
Airflow control                                                                                       position, a single
The direction and velocity of the airflow is regulated to suit                                        HDS fitting is
the parameters of a given gateway. For gates with a strong                                            required.
wind blowing through (or with a significant indoor and out-
door temperature differential) the air-discharge plane must
be shifted in an outward direction. The recommended dis-


74
                                                                                                                                                                                                                                                 HD
Electrical connection
The device is connected to the circuit via a three-pole cir-
cuit breaker with a minimum contact gap of 3 mm. The
front panel of the curtain can be opened by turning the fix-
ing screws 1/4 of a turn. Electrical connection is supplied
via SO5W-U, AO5W-R or similar cables. There are entry
ports in the top panel of the casing. 2 pieces of 37 mm in
diameter and 3 pieces of 29 mm in diameter.
Cable glands must fulfill the safety requirement for this
class of devices.
Power cable and control cable have two different inlets in
air curtains with electrical heating elements. The control
panel must say “The air curtain is powered by more than 1
circuit breaker”.




                                                                                         Electric circuits


            HD + HDR4 speed control + HDEV                                                                                 HD + HDGL gate sensor+ HDR4 control panel
                    power control                                                                                           + HDEV control panel + SR12 thermostat

                                                                                                                             HD8, HD12 400V 3(N)~ / 230V3~

 HD8, HD12 400V 3(N)~ / 230V3~                                                                                                                                                                               10 11 12 13       14                 L1 L2 L3
                                                                                                                                P N 1 2 3 4 5 6 7 8 9

                                                          10 11 12 13               14            L1 L2 L3
    P N 1 2 3 4 5 6 7 8 9
                                                                                                                                                                                                                                             400V 3~/230V 3~

                                                                                                                             HD8, HD12 400V 3(N)~ / 230V3~
                                                                                              400V 3~/230V 3~

 HD8, HD12 400V 3(N)~ / 230V3~                                                                                                                                                                               10 11 12 13       14                 L1 L2 L3
                                                                                                                                P N 1 2 3 4 5 6 7 8 9

                                                          10 11 12 13               14            L1 L2 L3
    P N 1 2 3 4 5 6 7 8 9
                                                                                                                                                                                                                                             400V 3~/230V 3~
                                                                                                                                L1 N (L2)
                                                                                                                                230 V~
                                                                                              400V 3~/230V 3~
    L1 N (L2)
    230 V~
                                                                                                                                                                                                                     5     1        6
                                                                                                                                                                      2     6    8                                                           Step 1
                     2     6     8                                       5   1                                                                                                              4 X       X                             5
                                      4 X       X                                       X X                                                                                                                          6     2
                                      3   X X   X                                                                                                                     1   3 5    7
                                                                                                                                                                                            3   X X   X                             4
                     1   3 5     7                                       6   2            X                                                                                                 2   X     X
                                      2   X     X                                     0 6 2
                                      1     X   X                                                                                                   HDGL                                    1     X   X                                               3
                                                                                                                                                                                            0                                           Step 2
                                      0                                                                                                                                         HDR4                              HDEV                                2
                               HDR4     1 3 5   7                       HDEV                                                                                                                  1 3 5   7
                                                                                                                                                                                                                                                      1
                                                                                                                                                                                                                      X X
                                                                                                                                                                                                                        X               Diff (1-4)K
                                                                                                                                                                                                                    O 6 2
                                                                                                                                                                                                                                    SR122




            HD + HDGL gate sensor + HDR42 speed control + HDEV power control + SR12 thermostat



                                                     HD                                                                       L1 L2 L3
                                                                                              4 5 6          10 12 13 14


                                                                                                                           400V3~/230V3~

                                                     HD
                                                                                 P N 1 2 3 4 5 6 7           10 12 13 14      L1 L2 L3



                                                                             L1 N (L2)                                     400V3~/230V3~
                                                                             230 V~                                                                               SR 12
                                                                                                                                                                                HI     LO


                                                                                  31 32 33 34 35 36 37 38                                   HDR42                                              °C


                                                                                                                                                                          1 1 2 3 4 5 6 7 L L N

                                                    HDGL


                                                                                                                                                                                                    L1 N
                                                                                                                                                                                                    230 V~




                                                                                                                                                              5   1

                                                           X     X                                                                                            6   2
                                                               X X
                                                                 X
                                                           X X X X
                                                           1 2 3 4                                                                                           HDEV




                                                                                                                                                                                                                                                             75
Air curtains
  HDW




                                                                                                                  Горизонтальный
                                                                                                                      монтаж




                                                                                                                   Вертикальный
                                                                                                                      монтаж




                                                                                                                      Водяной
                                                                                                                       нагрев




                                                                                                               HDW / HDWL
     Advantages

     • for doorways (up to 3.5 m)                                                0.5 м                            9.3 м/с
     • space-saving design
     • corrosion-proof steel casing made from gal-
     vanized sheet steel                                                         1.5 м                            6.4 м/с
     • overheating protection
     • air discharge plane can be displaced under
                                                                                 2.5 м                            4.7 м/с
     the required angle
     • ease of installation (both horizontal and ver-
     tical)
                                                                                 3.5 м                            3.8 м/с



                                                                               Air velocity profile

Recommended application                                            Automatics must be ordered separately. The HDR4 airflow
HDW is a powerful air curtain with a hot-water-based air-          velocity controller can regulate the operation of up to 14
heating element. The air curtain is installed above the door-      motors. The HDR42 regulator can be used to control the air
way or beside the gate in a column. The air curtains of this       flow velocity when the door is open and closed. Maximal
series can be used as a principal heating source in medi-          water temperature is 100 °C. Heat pick-up capacity
um-sized industrial facilities. HD curtains are recommended        depends on the temperature of the water in the circuit and
for doorways 2.5 - 3.5 m in height.                                of the air supplied to the curtain.

Construction                                                       Assembly
Fans and heating elements are mounted inside a corro-              The curtains can be installed both horizontally and vertically.
sion-proof steel casing. Depending on the HDW’s standard           They are installed above the doorway or beside the gate in
dimensions, it can have 2 or 3 centrifugal fans fitted. Air        a column. Connection to the output pipes of the air-heating
curtains are equipped with an air filter for protection of radi-   element is performed in the upper part of the casing via
ator section. Curtains are supplied in two standard sizes,         DN20 joints on the right.
with different lengths.
                                                                   Certificates
Motor                                                              Certificate of Conformity of the Russian Federation,
HDW air curtains are equipped with a powerful high-pres-           Ukraine, SEMKO and CE Standard.
sure centrifugal fan.

Speed control


76
                                                                                                                                HDW

                                                      Basic dimensions




                                                             Specifications



                                                      HDW                HDWV                       HDWL                 HDWVL
 Length                                  mm           1000               1000                       1670                 1670
 Power capacity, motors                    W          2 x 184            2 x 184                    3 x 184              3 x 184
 Voltage                                    V         230 1~             230 1~                     230 1~               230 1~
 Current                                   A          1.6                1.6                        2.4                  2.4
 Air consumption (low / high)           m3/h          800/1700           800/1700                   1200/2500            1200/2500
 Noise level                          dB(A)           44/62              44/62                      45/63                45/63
 Weight                                   kg          51                 51                         74                   74
 Protection index                                     IP24               IP24                       IP24                 IP24
 Product identification number                        3055               3209                       3169                 3210
 Price                                  Euro          1864,0             1924,0                     2545,0               2663,0




            A vertically installed air curtain prevents
            drafts if the airflow is reflected off the wall.




                                                                                               An example of HD curtain vertical
                                                                                               mounting
Accessories




HDR speed con-    HDGL sensor,      HDS mounting       FHWACT - actua-    FHW2RV        FHWAV                FHWSV stopping
  trols, p. 114     p. 118          bracket, p. 119      tor, p. 118                                           valve, p. 118
                                                                           Control valves, p. 118

                                                                                                                                     77
Air curtains
  HDW
Assembly                                                               The air flow velocity can be regulated with a fan speed
HDW air curtains with a water-based heating element are                HDR4 control panel, which is supplied separately and con-
designed for protection of doorways that are 2.5 - 3.5 m               trols up to 7 short (2 fans) or 4 long (3 fans) air curtains.
high. HDW and HDWL are designed for horizontal installa-
tion, while HDWV and HDWLV are designed for vertical                   Electrical connection
installation.                                                          The device is connected to the circuit via a three-pole cir-
Mounting consoles allow the airflow plane to be shifted in             cuit breaker with a minimum air gap of 3 mm. The front
the necessary direction, depending on the aerial load on               panel of the curtain can be opened by turning the fixing
one or other side of the gate. The higher the load caused              screws 1/4 of a turn. Electrical connection is supplied via
by wind, pressure and temperature differentials, the greater           SO5W-U, AO5W-R or similar cables. There are entry ports
the displacement angle of the airflow plane of the curtain             in the top panel of the casing. 2 pieces of 37 mm in diam-
should be towards the outside.                                         eter and 3 pieces of 29 mm in diameter. Cable glands
                                                                       must fulfill the safety requirement for this class of devices.
Horizontal installation
The air curtain is usually mounted inside the premises,
above the gateway, as close as possible to the horizontal
axis of the entryway. The blow out aperture of the curtain
must be as close as possible to the entryway.
If several curtains are installed, they should be closely
mounted next to one another, to avoid gaps in the air
flows. A mounting gap of 50 mm is required between the
curtains, to tighten the bolts holding the console. The con-
sole is mounted on M10 bolts in the central holes of the
console and on the sides of the curtain. The necessary cur-
tain inclination angle is fixed with M10 bolts in the respec-
tive holes of the console and the curtain. It is necessary to
observe the minimal distances and take care not to mount
the device immediately above a power socket.

Vertical installation
In case vertical mounting is required, HDWV and HDWLV mod-
els must be ordered, which are equipped with water-based
heat exchangers, designed for vertical mounting. The water
section has two inserts for the air relief valve, making it possible
to vertically mount the air curtain from both sides.
The curtains are fixed to the floor and each other using
HDS fittings. The curtains are mounted vertically inside the
premises, with the blowout aperture being as close as pos-
sible to the edge and horizontal axis of the gateway. For
two curtains installed on top of each other, two HDS fitting
sets must be ordered, each in turn consisting of two parts.                                                 The mounting con-
The outer part is attached to the floor (or the top end of the                                              soles are included in
lower curtain with M10 bolts) by anchor bolts inserted in the                                               the shipment.
central and semi-circular holes, while the inner part of the
fitting is attached to the end of the lower and upper cur-
tains. Prior to tightening the anchor bolts in the floor, place
the HDS at the correct angle to the gateway plane and
tighten the nuts. The fitting piece is fixed with 3 M10 bolts.                                              The HDS mounting
The maximum height of the column must not exceed 3.5                                                        brackets (additional
m.                                                                                                          accessory) can make
At the top end of the top curtain a console is installed to                                                 the installation quick
attach the column to the wall. The HDR4 fan speed control                                                   and easy.
panel can be installed in any convenient location.

Airflow control
The direction and velocity of the airflow is regulated to suit
the parameters of a given gateway. For gates with a strong
wind blowing through (or with a significant indoor and out-
door temperature differential) the air-discharge plane must
be shifted in an outward direction. The recommended dis-
placement angle is up to 15°. The angle of the air-dis-                                                     For a single curtain,
charge plane should increase as the pressure and temper-                                                    installed in a vertical
ature differentials between the premises and the outside                                                    position, a single
increase, as well as with an increase of velocity of the wind                                               HDS fitting is
blowing into the doorway. The optimal effectiveness is                                                      required.
reached when both sides of the doorframe are screened.


78
                                                                                                       HDW

                                      HDW - Pressure differential in the water circuit




                                            HDW - Heating power and increase of air temperature

                                                    Air supply       95/70         80/60           70/50
                                            ti°C                 Δti°C QkW      Δti°C QkW       Δti°C QkW
                                                        1        67.7   18.4     56.7    15.4   48.7   13.2
Air supply 1 = 900 m3/h                     0
                                                        4        54.0   31.3     45.1    26.0   38.7   22.3
Air supply 4 = 1300 m3/h                                1        59.5   16.1     48.5    13.2   40.5   11.0
ti°C = Air temperature at the inlet         +10
                                                        4        47.3   27.3     38.4    22.1   31.9   18.4
Δti°C = Increase of air temperature                     1        55.4   15.0     44.4    12.0   36.3    9.9
                                            +15
Q = Heating power                                       4        43.9   25.3     35.1    20.2   28.5   16.5
                                                        1        51.3   13.9     40.3    10.9   32.2    8.7
                                            +20
                                                        4        40.5   23.4     31.7    18.3   25.1   14.5




                                            HDWL - Heating power and increase of air temperature

                                                      Supply         95/70           80/60         70/50
                                             ti°C                Δti°C QkW       Δti°C QkW      Δti°C QkW
Air supply 1 = 900 m3/h                                 1        71.1   28.9     61.9    22.0   51.3   20.9
                                             0
Air supply 4 = 1300 m3/h                                4        59.7   49.1     48.9    41.4   41.6   35.2
ti°C = Air temperature at the inlet                     1        62.6   25.5     53.2    18.9   42.7   17.4
                                             +10
Δti°C = Increase of air temperature                     4        50.8   43.0     41.8    35.4   34.4   29.2
Q = Heating power                                       1        58.3   23.7     48.8    17.3   38.4   15.6
                                             +15
                                                        4        47.2   40.0     38.2    32.4   30.8   26.1
                                                        1        54.0   22.0     44.4    16.9   34.0   13.9
                                             +20
                                                        4        43.6   37.0     34.6    29.4   27.2   23.0




                                                                                                              79
Air curtains
  HF




                                                                                                                   Горизонтальный
                                                                                                                       монтаж




                                                                                                                    Вертикальный
                                                                                                                       монтаж




                                                                                                                   Electrical heating




      Advantages

      • for doorways (up to 4 m)
      • space-saving design
      • corrosion-proof steel casing made from gal-
      vanized sheet steel
      • overheating protection
      • air discharge plane can be displaced under
      the required angle
      • ease of installation (both horizontal and verti-
      cal)


                                                                           Air velocity profile


Recommended application                                         Automatics must be ordered separately. The HDR4 airflow
HF is a powerful air curtain with or without an electrical      velocity controller can regulate the operation of up to 14
heating element, designed for protection of doorways that       motors. The HDEV power controller regulates the electrical
are 3 - 4 m high, into shopping malls and warehouse facili-     heating. The HDGL door status sensor may be connected
ties. The air curtains of this series can be used for dehu-     to an HDEV controller (with on / off positions) or an HDR42
midification or as a principal heating source in medium-        controller (with high / low positions), in order to regulate the
sized industrial facilities.                                    airflow when the door opens and closes. The HDEV regula-
Due to the high power of HF curtains, the models without a      tor may be connected to an SR122 thermostat.
heating element can be used to protect doorways of refrig-
erator rooms or air-conditioned facilities.                     Assembly
.                                                               The curtains can be installed both horizontally and vertically.
Construction                                                    Installation into a false ceiling is also possible.
Design. Fans and heating elements (if they are included in
the design) are mounted inside a corrosion-proof steel cas-     Certificates
ing. Depending on the HDW’s standard dimensions, it can         Certificate of Conformity of the Russian Federation,
have 2 or 3 centrifugal fans fitted. Curtains are supplied in   Ukraine, SEMKO and CE Standard
two standard sizes, with different lengths.

Motor
HF air curtains are equipped with a powerful high-pressure
centrifugal fan.
Speed control

80
                                                                                                                     HF


                                                     Basic dimensions


           975 / 1640
                                                                                       710                   770
                                           ø 11                                                   1                     1

                                           ø 20
                                                                    490
                                   335                                    400



                                                                                                  2                     2
           1000 / 1670

                                                                            360                       360




                                                            Specifications



                                                     HF0                   HF12              HFL0           HFL18
 Length                                   mm         1000                  1000              1670           1670
 Power, heating                            kW        -                     12                -              18
 Power capacity, motors                     W        3 x 192               3 x 192           5 x 193.2      5 x 193.2
 Voltage                                    V        230 1~                400 3~            230 1~         400 3~
 Current                                    A        2.5                   17.3              4.2            26.0
 Air consumption (low / high)            m3/h        1350/2700             1350/2700         2250/4500      2250/4500
 Temperature increase                      °C        -                     27/13             -              27/13
 Noise level                             dB(A)       44/62                 44/62             45/63          45/63
 Weight                                    kg        44                    54                71             86
 Protection level                                    IP24                  IP24              IP24           IP24
 Product identification number                       7975                  7977              7976           7978
 Price                                   Euro        1739,0                2458,0            2516,0         3338,0




Accessories




HDR speed con-   HDEV power con-   SR thermostats,   HDGL sensor,   HDS mounting
 trols, p. 114     trols, p. 115       p. 117          p. 118       bracket, p. 119


                                                                                                                        81
Air curtains
  HF

Assembly                                                         The location of the lower HDS must allow the top console
HF is a powerful air curtain with or without an electrical       to be mounted on the wall.
heating element, designed for protection of doorways 3 - 4
m in height. The curtains are supplied in two standard sizes     The HDR4 fan speed control panel can be installed in any
with different lengths and they may be installed both hori-      convenient location. The HDR4 can regulate up to 14
zontally and vertically. Their compact design allows them        motors. When mounting curtains with electrical heating ele-
to be installed into a false ceiling.                            ments, the HDEV power control panel is installed next to
HF curtains can be mounted on a wall or ceiling by brack-        HDR4. A thermostat (for example, SR122) is placed in a
ets supplied along with the device or suspended from the         location where it will most accurately measure the air tem-
ceiling via a flexible cord. Curtains mounted on brackets        perature changes at the gate zone.
can be turned at the required angle. Mounting consoles           If excessive draft is felt in the gateway under a vertical
allow the airflow plane to be shifted in the necessary direc-    installation, it is recommended to install a narrow separa-
tion, depending on the aerial load on one or other side of       tion wall on the side of the gate facing the curtain column.
the gate. The higher the load caused by wind, pressure
and temperature differentials, the greater the displacement      HF Electrical connection
angle of the airflow plane of the curtain should be towards      The device must be connected to the power circuit by a
the outside.                                                     qualified electrician, with all the relevant safety require-
The effectiveness of curtain’s operation depends on the          ments observed. The device is connected to the circuit via
temperature and pressure differential between the premis-        a three-pole circuit breaker with an air gap of 3 mm.
es and the outside, as well as on the strength of wind blow-     Double insulation cables of the appropriate diameter are
ing from the outside.                                            used, which are fed into the curtain through removable
                                                                 knock-outs in the upper part of the casing. (2 of a 38 mm
Horizontal installation above the gateway                        diameter and 3 of a 29 mm diameter). The terminal clamps
The air curtain is usually mounted inside the premises,          are designed for power cables up to 16 mm in diameter
above the gateway, as close as possible to the horizontal        and control cables up to 6 mm max. 16mm2 and control -
axis of the entryway.                                            max. 6 mm2. For curtains with an electric heating element,
If the air curtain is used to protect a refrigerator room, it    power load and control panel power supply are produced
should be mounted                                                separately.
on the warm side of the premises.
The devices must be hung close to one another, to avoid
gaps in the
airflows.
When mounting into a false ceiling (Fig. 2). good air circu-
lation around the device must be insured. The minimal dis-
tances for a curtain with electrical heating element are
shown on Fig. 1. The console is mounted on M10 bolts in
the central holes of the console and on the sides of the
curtain. The necessary curtain inclination angle is fixed with
M10 bolts in the respective holes of the console and the
curtain.
Observe the minimal distances and take care not to mount
the device immediately under / above a power socket.

Horizontal installation above a gateway opening
upward
In case the curtains are installed above automatic gates,
which open upwards and into the premises, they will have
to be mounted far away from the gate, which significantly
lowers their effectiveness. Use the AXT1 and AXT2 section
(Fig. 3), which are mounted on their respective curtains

Vertical Mounting to the side of the doorway
In case there is not enough space above the gates for the
horizontal location of air curtains or, for various reasons,
the horizontal installation is impossible or undesirable, the
curtains are in a column to the side of the gate, creating a
side airflow. The curtains are fixed to the floor and each
other using HDS fittings. For a two-curtain column, two
                                                                   For a single curtain,
HDS fitting sets must be ordered. Curtains making up the
                                                                   installed in a vertical
column must cover the entire height of the doorway and be
                                                                   position, a single
located as close to the entryway as possible. The height of        HDS fitting is
a curtain column, excluding additional mounting elements,          required.
must not exceed 3.5 m.
At the top end of the top curtain a console is installed to
attach the column to the wall.


82
                                                                                                                                                                         HF


                                                min 200




Fig. 1: Minimal distances                                                                               Fig. 2: Installation into a false ceiling


                                                                                  1120
                                                                                  1070




                                                                                     945


                                                                       Fig. 3: AXT Section




                                                                       Electric circuits

                                         HF + HDR4 control panel + SR122 thermostat



HF
                                                                                                                                       400 V3~
M         c°   M   c°   M         c    M       c     M            c°
~              ~        ~          °
                                       ~        °
                                                     ~
                                                                                         230 V3~


                                                                        PTC



    L N                     L N                           L N                 L
                                                                                                   c°
                                                                                                              K1          K2                          K3


                                                                                                   c°




                                                                                                        10 11 12 13            14                15           L1 L2 L3
    P N 1 2 3 4 5 6 7 8 9

                                                                                                                                                           400V 3~/230V 3~


 L1 N (L2)
 230 V~
                                                                                                                          1
                                  2      6 8                                                                                         Hi
                                                                                                                          2
                                                    4 X       X
                                  1    3 5 7                                                                              3
                                                    3   X X   X
                                                    2   X     X
                                                    1     X   X                                                                              1
                                                                                                                               Lo
                                                    0                                                                                        2
                                  HDR4                1 3 5   7                                                                              3

                                                                                                                               Diff (1 4)K

                                                                                                                          SR122




                                                                                                                                                                             83
Air curtains
    HFW




                                                                                                              Горизонтальный
                                                                                                                  монтаж




                                                                                                                Вертикальный
                                                                                                                   монтаж




                                                                                                                 Водяной
                                                                                                                  нагрев




      Advantages

      • for doorways (from 3 to 4 m)
      • space-saving design
      • corrosion-proof steel casing made from gal-
      vanized sheet steel
      • overheating protection
      • air discharge plane can be displaced under
      the required angle
      • ease of installation (both horizontal and verti-
      cal)


                                                                           Air velocity profile



Recommended application                                        Automatics must be ordered separately. The HDR4 airflow
HFW is a powerful air curtain with a hot-water-based air-      velocity controller can regulate the operation of up to 14
heating element. The HFW curtain is installed in column        motors. The HDGL door status sensor may be connected
above or beside the gates. It is recommended for door-         to an HDR42 controller (with high / low positions), in order
ways that are 3 - 4 m high.                                    to regulate the air flow when the door opens and closes.
.
Construction                                                   Assembly
Fans and heating elements are mounted inside a corro-          The curtains can be installed both horizontally and vertically.
sion-proof steel casing. Depending on standard dimension,      They are installed above the doorway or beside the gate in
HFW curtains are equipped with two (air curtains, 1,000        a column. Connection to the output pipes of the air-heating
mm long) or three (air curtains, 1,670 mm long) centrifugal    element is performed in the upper part of the casing via
fans. Curtains are supplied in two standard sizes, with dif-   DN20 joints on the right.
ferent lengths.
                                                               Certificates
Motor                                                          Certificate of Conformity of the Russian Federation,
HFW air curtains are equipped with a powerful high-pres-       Ukraine, SEMKO and CE Standard.
sure centrifugal fan.
Speed control




84
                                                                                                                             HFW


                                                    Basic dimensions


           975 / 1640
                                                                                         710                          770
                                         ø 11                                                          1                           1

                                         ø 20
                                                                      490
                                 335                                        400



                                                                                                       2                           2
           1000 / 1670

                                                                              360                            360




                                                          Specifications



                                                   HFW                       HFLW                 HFWV               HFLWV
 Length                                 mm         1000                      1670                 1000               1670
 Water volume                               l      2,5                       3,5                  2,5                3,5
 Power capacity, motors                   W        3 x 192                   5 x 193.2            3 x 192            5 x 193.2
 Voltage                                   V       230~1                     230~1                230~1              230~1
 Current                                   A       2.5                       4.2                  2.5                4.2
 Air consumption (low / high)          m3/h        1050/2400                 1800/4000            1050/2400          1800/4000
 Noise level                           dB(A)       44/62                     45/63                44/62              45/63
 Weight                                   kg       52                        83                   52                 83
 Protection level                                  IP24                      IP24                 IP24               IP24
 Product identification number                     7971                      7973                 7972               7974
 Price                                 Euro        2413,0                    3407,0               2501,0             3642,0




Accessories




HDR speed con-    HDGL sensor,   HDS mounting       AXT mounting       FHWACT - actua-    FHW2RV         FHWAV         FHWSV stopping
  trols, p. 114     p. 118       bracket, p. 119   sections, p. 119      tor, p. 118                                     valve, p. 118
                                                                                            Control valves, p. 118

                                                                                                                                    85
Air curtains
 HFW

     HFW - Heating power and increase of air temperature

             Supply          95/70        80/60          70/50
     ti°C                Δti°C QkW     Δti°C QkW     Δti°C QkW       Air supply 1 = 1050 m3/h
                1        73.6   30.0   64.2   24.4    54.6   20.7    Air supply 4 = 2400 m3/h
     0
                4        63.6   55.2   53.7   46.6    45.5   39.4    ti°C = Air temperature at the inlet
                1        75.0   23.8   65.4   20.3    55.7   16.8    Δti°C = Increase of air temperature
     +10
                4        66.3   47.2   56.3   38.8    78.0   31.8    Q = Heating power
                1        77.9   22.7   65.9   18.4    56.1   14.8
     +15
                4        67.6   43.4   57.6   35.1    49.2   28.1
                1        78.7   20.7   66.4   16.5    56.5   12.9
     +20
                4        68.8   39.6   58.8   31.4    50.3   24.5




     HFLW - Heating power and increase of air temperature

            Air supply       95/70        80/60           70/50
     ti°C                Δti°C QkW     Δti°C QkW      Δti°C   QkW
                                                                     Air supply 1 = 1800 m3/h
                1        77.2   50.3   65.1   42.4    55.6    36.2
     0                                                               Air supply 4 = 4000 m3/h
                4        65.4   94.6   55.3   80.0    46.9    67.9
                1        78.5   43.0   66.3   35.4    56.7    29.3   ti°C = Air temperature at the inlet
     +10
                4        68.0   81.0   57.8   66.7    49.3    54.9   Δti°C = Increase of air temperature
                1        79.0   39.6   66.7   32.1    57.1    26.0   Q = Heating power
     +15
                4        69.9   74.5   58.9   60.3    50.4    45.7
                1        79.5   36.2   67.3   28.8    57.5    22.8
     +20
                4        70.4   68.1   60.1   54.1    51.5    42.5




     HFWV Heating power and increase of air temperature

            Air supply       95/70        80/60           70/50
     ti°C                Δti°C   QkW   Δti°C QkW      Δti°C  QkW     Air supply 1 = 1050 m3/h
                1        71.9   27.3   60.6   23.0    51.2    19.5   Air supply 4 = 2400 m3/h
     0
                4        58.7   51.0   49.6   43.0    41.7    36.2   ti°C = Air temperature at the inlet
                1        73.5   23.3   62.2   19.1    52.6    15.6   Δti°C = Increase of air temperature
     +10
                4        62.0   43.5   52.7   35.8    44.6    29.0   Q = Heating power
                1        74.3   21.4   62.9   17.3    53.2    13.8
     +15
                4        63.4   39.9   54.1   32.2    46.0    25.5
                1        74.9   19.5   63.5   15.4    53.6    11.9
     +20
                4        64.9   36.4   55.5   28.8    47.3    22.1




     HFLWV Heating power and increase of air temperature

            Air supply       95/70         80/60          70/50
     ti°C                Δti°C   QkW   Δti°C   QkW    Δti°C   QkW
                                                                     Air supply 1 = 1800 m3/h
                1        70.8   46.1   59.7   38.9    50.2    32.7
     0                                                               Air supply 4 = 4000 m3/h
                4        58.1   84.0   49.0   70.9    41.0    59.4
                                                                     ti°C = Air temperature at the inlet
                1        72.5   39.3   61.2   32.2    51.5    26.1
     +10                                                             Δti°C = Increase of air temperature
                4        61.3   71.6   52.1   58.8    44.0    47.4
                                                                     Q = Heating power
                1        73.2   36.0   61.9   29.0    52.0    22.9
     +15
                4        62.7   65.6   53.5   52.9    45.3    41.6
                1        73.8   32.8   62.5   25.8    52.4    19.7
     +20
                4        64.2   59.7   54.9   47.1    46.6    35.9




86
                                               HFW


HFW pressure difference in the water circuit




                                                 87
Air curtains
  HFW

Assembly                                                        The HDR4 fan speed control panel can be installed in any
HFW are powerful air curtains with water-based heating,         convenient location. The HDR4 can regulate up to 14
designed for protection of doorways that are 3 - 4 m            motors. When mounting curtains with electrical heating ele-
high.Curtains are supplied in two standard sizes with differ-   ments, the HDEV power control panel is installed next to
ent lengths and they can be installed both horizontally         HDR4. A thermostat (for example, SR122) is placed in a
(HFW and HFLW models) and vertically (HFWV ? HFWV               location where it will most accurately measure the air tem-
models). Their compact design allows them to be installed       perature changes at the gate zone.
into a false ceiling.                                           The HDGL door status sensor may be connected to an
HFW curtains can be mounted on the wall or ceiling by           HDEV controller (with ON / OFF positions) or an HDR42
brackets supplied along with the device or suspended from       controller (with high / low positions), in order to regulate the
the ceiling on a flexible cord. Curtains mounted on brack-      airflow when the door opens and closes.
ets can be turned at the required angle. Mounting consoles      If excessive draft is felt in the gateway under a vertical
allow the airflow plane to be shifted in the necessary direc-   installation, it is recommended to install a narrow separa-
tion, depending on the aerial load on one or other side of      tion wall on the side of the gate facing the curtain column.
the gate. The higher the load caused by wind, pressure
and temperature differentials, the greater the displacement     HFW Electrical connection
angle of the airflow plane of the curtain should be towards     The device must be connected to the power circuit by a
the outside.                                                    qualified electrician, with all the relevant safety require-
The effectiveness of curtain’s operation depends on the         ments observed.
temperature and pressure differential between the premis-       Use double insulation cables of the appropriate diameter,
es and the outside, as well as on the strength of wind blow-    which are fed into the curtain through removable knock-
ing through the doorway.                                        outs in the upper part of the casing. Main line connection
                                                                nozzles (with internal thread) are located in upper part of
Horizontal installation above the gateway                       the casing.
The air curtain is usually mounted inside the premises,         Maximum water temperature is up to 100°.
above the gateway, as close as possible to the horizontal
axis of the entryway.
The devices must be hung close to one another, to avoid
gaps in the
airflows.
The console is mounted on M10 bolts in the central holes
of the console and on the sides of the curtain. The neces-
sary curtain inclination angle is fixed with M10 bolts in the
respective holes of the console and the curtain.
Observe the minimal distances and take care not to mount
the device immediately under / above a power socket.

Horizontal installation above a gateway opening
upward
In case the curtains are installed above automatic gates,                                            AXT mounting sections
which open upwards and into the premises, they will have                                             could be ordered addi-
to be mounted far away from the gate, which significantly                                            tionally to bring the dis-
lowers their effectiveness. Use the AXT1 and AXT2 section                                            charge plane closer to
(Fig. 3), which are mounted on their respective curtains                                             the gateway.
and can help to bring the blow out aperture of the curtain
closer to the gateway plane. 3), which are mounted on their
respective curtains

Vertical Mounting to the side of the doorway
In case there is not enough space above the gates for the
horizontal location of air curtains or, for various reasons,
the horizontal installation is impossible or undesirable, the
curtains are in a column to the side of the gate, creating a
side airflow. The curtains are fixed to the floor and each
other using HDS fittings. For a two-curtain column, two                                              Use the HDS mounting
HDS fitting sets must be ordered. Curtains making up the                                             brackets (additional
column must cover the entire height of the doorway and be                                            accessory) for installa-
located as close to the entryway as possible. The height of                                          tion HF curtains in the
a curtain column, excluding additional mounting elements,                                            column.For a single air
must not exceed 3.5 m.                                                                               curtain, installed in a verti-
At the top end of the top curtain a console is installed to                                          cal position, a single HDS
attach the column to the wall.                                                                       fitting is required.
The location of the lower HDS must allow the top console
to be mounted on the wall.



88
                                                                                                                  HFW



                                  min 200




Fig. 1: Minimal distances                                             Fig. 2: Installation into a false ceiling


                                                        1120
                                                       1070




                                                          945


                                              Fig. 3: AXT Section




                            Manufacturing HF air curtains at the Systemair factory, Sweden.




                                                                                                                    89
Air curtains
 HFW

                                           Electric circuits

          HFW + HDGL door status sensor + HDR4 controller + RT 0 - 30 thermostat



       FHWACT                          HFW                  P N 1 2 3 4 5 6 9



        (TRV25)

                                       HFW                  P N 1 2 3 4 5 6 9

           1
           2
           3
           4
           5

                                                                                          2     6 8
     RT 0 30
                                                                                          1   3 5 7
                                                                               HDGL

                                                           L1 N (L2)                    HDR4
                                                           230 V~



         HFW + HDGL door status sensor + HDR42 controller + FHWACT valve actuator



           FHWACT
                                  HFW                            4 5 6 9


          FHW2RV25
                                   HFW               P N 1 2 3 4 5 6 9




                               L1 N (L2)
                               230 V~

                                                      3132 33 34 35 36 37 38          HDR42
               1
               2
               3

                              HDGL
        SR 121




                                           X     X
                                               X X
                                                 X
                                           X X X X
                                           1 2 3 4




90
                                                                                                                               HFW

                                                           Electric circuits

             HFW + HDGL door status sensor + HDR4 controller + RT 0 - 30 thermostat



                        HFW            P N 1 2 3 4 5 6 9                                       HFW            P N 1 2 3 4 5 6 9



                        HFW            P N 1 2 3 4 5 6 9                                       HFW            P N 1 2 3 4 5 6 9




FHWACT                                                                   FHWACT



FHW2RV20                                                                 FHW2RV20

      FRE6M                                                                   FRE6S
           L N N U TK TK 1 2 5 6 101112 21222324                                    L N N U TK TK 1 2 14 11     21222324



         L1 N (L2)                                                                L1 N (L2)
         230 V~                                                                   230 V~




                        Внешний
                        датчик


                                  Комнатный Дверной
                                  термостат выключатель


                      HFW + HDGL door status sensor + HDR4 controller + RT 0 - 30 thermostat



                     FHWACT


                                                   HFW        P N 1 2 3 4 5 6 9
                     (TVV20/25)




                                                   HFW        P N 1 2 3 4 5 6 9
                         1
                         2
                         3
                         4
                         5


                RT 0 30                                                                        2 4   6 8       4 X       X
                                                                                                               3   X X   X
                                                                                               1   3 5 7
                                                                                                               2   X     X
                                                                   HDGL                                        1     X   X
                                                                                                               0
                                                                                                                 1 3 5     7
                                                                                              HDR4

                         1
                         2
                         3
                         4
                         5


                RT 0 30

                                                             L1 N (L2)
                                                             230 V~


                                                                                                                                  91
Air curtains
  MTV Industrial



                                                                                                                   Осевой
                                                                                                                 вентилятор




                                                                                                               Горизонтальный
                                                                                                                   монтаж




                                                                                                                Вертикальный
                                                                                                                   монтаж




      Advantages

      • for doorways (from 3 to 6 m)
      • space-saving design
      • corrosion-proof steel casing made from gal-
      vanized sheet steel
      • air discharge plane can be displaced under
      the required angle
      • ease of installation (both horizontal and verti-
      cal)



                                                                           Air velocity profile
Recommended application
MTV is the most powerful air curtain. It creates an air barri-    Speed control
er in high doorways of warehouses and factory loading ter-        The fan speed is regulated by a controller, such as REU.
minals. MTV is designed for doorways that are 3 - 6 m             The air curtains can be programmed to change the airflow
high. The curtain does not have a heating element, but            velocity, depending on whether the door is open or closed.
nonetheless, it heats up the premises by forceful recircula-      To achieve that, a gate status sensor, such as HDGL, is
tion of overheated air from the ceiling into the work zone.       connected to an REU controller.
Tall doorways are a major source of heat loss, so installing
the curtain would drastically reduce heating costs. If the        Assembly
curtain is installed at the entrance to refrigerator rooms, its   The curtains can be mounted both horizontally above the
powerful airflow will stabilize the humidity in the room and      gateway or vertically.
prevent freezers from ice mound.
                                                                  Certificates
Construction                                                      Certificate of Conformity of the Russian Federation,
Axial fans and motors are mounted inside a corrosion-proof        Ukraine, SEMKO and CE Standard.
steel casing coated with powder paint. The guide shutters
tilt the airflow to compensate the pressure differential creat-
ed during the opening of the gates. The air intake is per-
formed in the top panel of the casing. Curtains are supplied
in two standard sizes, with different lengths.

Motor
Air curtains are equipped with axial fan and motor with
outer rotor.


92
                                                                                               MTV Industrial

                                                        Basic dimensions




                                                             Specifications



                                                                            MTV41       MTV61
Length                                               mm                     1040        1560
Power capacity, motors                                 W                    2 x 161     3 x 161
Voltage                                                 V                   230~1       230~1
Current                                                 A                   1.6         2.5
Air consumption (low / high)                        m3/h                    5700        8500
Noise level                                       dB(A)                     max. 60     max. 62
Weight                                                 kg                   60          90
Protection index                                                            IP44        IP44
Product identification number                                               3074        3076
Price                                               Euro                    1986,0      2649,0




Accessories




  REU trans-        RE trans-     REE thyristor, p. S-ET 10 motor pro-   HDGL sensor,
former, p. 115   former, p. 116         116           tection, p. 115      p. 118


                                                                                                            93
Air curtains
  MTV Industrial
Assembly                                                          The device must be connected to the power circuit by a
MTV industrial, the most powerful model in the series, is         qualified electrician, with all the relevant safety require-
designed for protection of tall or wide doorways, 3.5 - 6 m       ments observed.
high. The curtain does not have a heating element,                Separate thermal protection relays for the motor (S-ET10)
because it is made redundant by the powerful airflow gen-         must be used. S-ET10 can control up to 9 fan motors (3 - 4
erated by the curtain, which acts as a reliable barrier           curtains).
against heat loss and cold drafts, while helping conserve         A 5-step REU transformer must be used to regulate the
energy.                                                           speed. There are four standard sizes of the REU – 1.5 A,
MTV Industrial can be mounted both horizontally and verti-        3A, 5 A and 7 A. The size of the REU is selected based
cally.                                                            on the number of motors installed. Each MTV curtain motor
                                                                  takes up 0.6 A.
Mounting consoles allow the airflow plane to be shifted in        REU has two speed ranges, set by two switches. The
the necessary direction, depending on the aerial load on          speed ranges are changed by an additional circuit breaker
one or other side of the gate. The higher the load caused         (i.e. micro switch).
by wind, pressure and temperature differentials, the greater
the displacement angle of the airflow plane of the curtain
should be towards the outside.
Please note that when using the air curtain to protect a
refrigerator chamber, it must be mounted on the outer part
of the chamber.

Horizontal installation
Systemair air curtains are hung on the inside of the door-
way, as close to the upper end of the doorframe as possi-
ble. If several curtains are being installed, they must be
mounted side by side to avoid gaps in the airflow plane.
The top side of the device must be at least 30cm away
from the ceiling, to ensure an unobstructed air supply to
the curtain.
The curtain is installed on mounting brackets (supplied with
the curtain) as close to the doorway as possible. In case a
vertical-lifting door is installed, the curtain must be mounted
on a suspended beam, attached to the lower part of the
door lifting mechanism. A steel section or reinforced wood-
en beam fixed from both ends must be used.
The fan motor lead-outs are shorted to a terminal block
located at the top of the device in accordance with the cir-
cuit diagram.
Make sure that propeller spins freely and all transportation
fixtures are removed.
Set the airflow direction. This is very important!

Vertical installation
The curtains are installed in a column to the side of the
doorway, generating a horizontal airflow along the entire
height of the doorway. The devices are installed on mount-
ing brackets as close to the doorway as possible. Since the
air intake takes place through the upper part of the casing,
a 30 cm gap between it and the ceiling is required for
unhindered access for the air.
When installing the curtain in a vertical position, note that,
in order to eliminate cold drafts, the airflow must collide
with the opposite side of the gate.

Airflow control
The guide shutters tilt the airflow to compensate the pres-
sure differential created during the opening of the gates.
The wind pressure and draught affect the operation of the
curtain and can cause it to start drawing air from the out-
side into the building. In order to prevent this, the air dis-
charge plane must be directed from 15 to 30° towards the
outside.                                                            An example of correct installation of an MTV curtain: an
Note: In cooled premises the airflow must be directed 15 to        opening gate folds to the side, creating an aperture equal
30° towards the warm side.                                              to the combined widths of installed air curtains.
                                                                              Systemair warehouse gate, Sweden.
Electrical connection

94
                                                                                   MTV Industrial


                                                     Electric circuits



          MTV                                  MTV                       MTV


             M        M         M               M        M       M        M       M         M
             ~        ~         ~               ~        ~       ~        ~       ~         ~




           U1 U2      1 2 3 4 5                U1 U2      1 2 3 4 5      U1 U2    1 2 3 4 5




           U1 U2                TK                                        M      0.135 kW
                                                                          ~


           U1 U2
                           S-ET 10




           U1 U2          1 2    3

                                                HDGL
           L1 N
                                REU


           230V~




An example of correct installation of an MTV
curtain: the gate opens upward and, for
gateway protection, three air curtains are
required.
Systemair warehouse gate, Sweden.




                                                                                                95
                                Systemair fan heaters

                   Portable fan heaters                      Fixed and portable fan heaters
                       Proff Series                          Fan heaters provide high thermal output and fast heating at
                                                             low costs. Compared to other methods of heating, fan
                                                             heaters have the lowest cost of heating strength and are
                                                             perfectly suited for public places.
                                                             They provide the fastest and most effective way to warm
                                                             up poorly heated premises, gyms, industrial and ware-
                                                             house facilities etc.

                                                              Reliable and effective System air fan heaters have per-
                                                             formed very well in areas with exceptional demands to
                                                             device safety: in premises with a fire hazard and agricultur-
                                                             al storage facilities.

                                                             Portable fan heaters are truly essential, when it comes to
                                                             drying premises at construction sites.
•   8 standard sizes and power types
•   designed both for heating and dehumidifying premises     Fixed models are often installed in industrial and storage
•   low noise level                                          facilities. They can be used as an additional source of heat,
•   compactness and low weight                               especially during cold days.
•   Additional accessories are not required (ready to use)   The process of heating is based on forced exchange of
•   possible rigid fixing on a wall                          cold air in the premises to air warmed up by the fan.

                                                             Cost-effective solution
                                                             Fan heaters are the most economically feasible method of
                                                             heat provision, due to the low cost per kW of power for the
                                                             device.
                                                             High effectiveness of fan heaters is explained by their rate
                                                             of thermal transfer (hc). The high rate of thermal transfer
                                                             reflects the high rate of energy transfer (W/m 2K). The rate
                                                             of thermal transfer between the heater and a forcefully
                                                             induced air current (forced convection) is 3 - 8 times higher
                                                             than between a heater and still air (natural convection).
                                                             This means that, for a given rate of heat transfer, the area
                                                             of the fan heater’s heating element can be 8 times smaller
                                                             than that of a regular electrical convector. On top of that,
                                                             the fan heater creates a forced circulation of warm air on
                                                             the premises.

                                                             The size of propellers in the Systemair fan heaters is com-
                                                             mensurable with the device’s heating efficiency.
                                                             The reason behind this is the well known fact that warm air
                                                             (as opposed to hot air) is easier to distribute around the
                                                             premises. In addition, to generate the same air speed, a
                                                             large fan can work at lower speeds than a small one, gen-
                                                             erating less noise and ensuring a longer service life.
                                                             Stationary (wall mounted) and portable models are simple
                                                             to install and operate.




96
                                Systemair fan heaters

Fan heaters are a combined system of ventila-                                       Fixed fan heaters
tion and heating                                                                       FHW Series
In premises with no ventilation, air would be supplied by
fans to the heating element until the set ambient tempera-
ture is reached. After that the thermostat will continue moni-
toring the air temperature, switching on the heaters when it
drops.
If the fan heaters provide additional ventilation to the prem-
ises, the need arises to find out the consumed electrical
power for heating a set volume of air per unit of time and
select the appropriate model and the requisite quantity,
based on that calculation.

Stationary fan heaters will be far more effective if they are
connected to a mixing unit (chamber), which controls the
way air supplied from the outside mixes with the warm air,       • 4 standard sizes
before reaching the fan.                                         • water-based air heater
The mixing chamber can be packaged with additional con-          • combining of ventilation and heating is possible
trol automatics, which, in accordance with the set temper-       • wall or ceiling mounting
ature regime, will regulate the opening and closing of air       • low noise level
dampers with a timer.                                            • for heating of warehouse and industrial facilities, shops,
                                                                 trade pavilions etc.
The importance of proper placement
When selecting air as a heat carrier, the undesirable ten-
dency of hot air to rise should be taken into account.
Thus, fan heaters are most effective in premises with low-
medium ceilings (approximately up to 5 m in height). If the
ceiling height is more than 5 m, the fan heaters must be
equipped with a device, directing the hot air that has accu-
mulated under the ceiling downwards.

The fan heaters must be evenly spread around the room.
The key to top efficiency is the even spread of heat cur-
                                                                                    Fixed fan heaters
rents from the fan heaters. The joint operation of fan
heaters can be regulated by thermostat.                                                FHC Series

A stationary fan heater can be connected to a mixing
chamber to provide an air supply into the building from the
outside, as well as to properly mix the outsider and inside
air. This is the simplest solution to supply outside warm air
into the building. The mixing chamber can be equipped
with simple and inexpensive automatics, which open and
close the air dampers in accordance with the set time and
depending on the desired temperature set inside the prem-
ises.

The sound pressure is given in dB(A) for each fan and is
measured 4 m away from the device, in a 400 m2 premis-           • 3 standard sizes
es in accordance with ISO 3741.                                  • water-based air heater
                                                                 • wall or ceiling mounting
                                                                 • low noise level
                                                                 • for heating of warehouse and industrial facilities, shops,
                                                                 trade pavilions etc.




                                                                                                                            97
Portable fan heaters
  Proff




     Advantages

     •   compact portable fan heater
     •   effective for dehumidifying premises
     •   corrosion-proof steel casing
     •   overheating protection
     •   possible rigid fixing on a wall




Recommended application                                          fan speeds, when the low heating power is set, and at high
Proff are a series of compact and durable portable fan           speed, when the two higher heating power levels are set. In
heaters, designed to heat construction sites, warehouses,        2 - 9 kW models, when the electric motors inside the cas-
workshops, offices, trade pavilions etc.                         ing are switched on, the fan operates only when the ther-
Proff devices are effective at drying construction sites and     mostat is set to heating. This saves energy by cutting down
can be mounted on walls. It is not recommended to use            fan running time and ensures it does not blow cold air. The
Proff models in the immediate vicinity of swimming pools         power and speed switch is located on the fan heater’s cas-
and other places with excessive humidity.                        ing. Proff is equipped with overheating protection. The ther-
                                                                 mal protection is reset by pressing a button on PRO2 -
Construction                                                     15casing or under the cover of PRO20 - 30 models.
Fan heaters are made from corrosion-proof steel with heat-
ing elements from stainless steel. The casing is covered         Assembly
with a light-gray powder varnish, equipped with a front grille   Fan heaters may also be rigidly mounted on the wall.
and a black stand. Proff 2 and 3 kW are supplied with a 2
m cable and a grounded plug. Proff 5 and 9 kW are sup-           Certificates
plied with a 2 meter cable and a round CEE plug for a            Certificate of Conformity of the Russian Federation,
three-phase power supply. Proff 15, 20 and 30 kW are sup-        Ukraine, SEMKO and CE Standard.
plied with a 1.8 m cable and no plug. The thermostat oper-
ates within 5 - 40 °C.




Speed control
The devices are equipped with a speed / power selection
switch and a thermostat. Proff 2 - 15 kW have a set fan
speed and 2 heating levels. Proff 20 - 30 kW will run at low

98
                                                                                         Proff

                                          Basic dimensions




             Dimensions
Model Name     A          B        C




                                                             B
PRO2/3/5      285       340       405
PRO9          345       410       490
PRO15         415       500       525
PRO20/30      630       568       594


                                                 A                               C




                                          Specifications



                                              PRO221       PRO321    PRO343          PRO543
 Power                         kW             2            3         3               5
 Voltage                         V            230~1        230~1     400 3N~         400 3N~
 Current                         A            8.8          13.2      4.3             7.2
 Temperature increase           °C            21           32        32              31
 Air consumption             m3/h             280          280       280             480
 Noise level                dB(A)             35           37        37              37
 Weight                         kg            6.3          6.7       7.2             7.9
 Protection index                             IP44         IP44      IP44            IP44
 Product identification number                3092         3093      3094            3096
 Price                       Euro             186,0        220,0     235,0           284,0

                                              PRO943       PRO1543   PRO2043         PRO3043
 Power                         kW             9            15        20              30
 Voltage                         V            400 3N~      400 3N~   400 3N~         400 3N~
 Current                         A            13.0         21.9      29.5            43.9
 Temperature increase           °C            37           43        21/23           47/36
 Air consumption             m3/h             720          1050      1900/2600       1900/2600
 Noise level                dB(A)             48           52        66/74           66/74
 Weight                         kg            11           16.1      29.3            32.8
 Protection index                             IP44         IP44      IP44            IP44
 Product identification number                3098         3100      3127            3129
 Price                       Euro             342,0        580,0     1165,0          1268,0




Accessories

Additional accessories are not required



                                                                                                 99
Fixed fan heaters
  FHW




                                                                                                                  Водяной
                                                                                                                   нагрев




      Advantages
                                                                                              Outlet
      •   compact fixed fan heater
      •   effective for heating premises
      •   corrosion-proof steel casing
      •   possibility of air supply in any direction
      •   low noise level                                                                     Inlet




Recommended application
FHW is a series of compact, highly effective fan heaters          Assembly
with a water-based heating element. They are designed for         The fan heater is attached to the wall or ceiling.
heating manufacturing facilities, trade warehouses, work-         The lower and upper panels of the casing are easily
shops, shops, trade centers, conference halls and other           removed. There are hinges on the casing to make installa-
similar facilities with a low noise requirement. The air is       tion and servicing of the device easier.
heated by passing through a hot water coil, with minimal          The water pipes can be connected both on the left and
noise generation (for the FHW model it is 35 dB(A)).              right side of the device.

Construction                                                      Certificates
The fan heater consists of an axial fan and a hot water coil      Certificate of Conformity of the Russian Federation,
mounted in a corrosion-proof, galvanized steel casing.            Ukraine, SEMKO and CE Standard.
All models have grilles with freely adjustable shutters, allow-
ing the supply of air in any direction.


Speed control
The fan has several speed settings. Hot air could be com-
bined with air from the outside in a mixing chamber.
Several additional accessories are available for regulation
purposes.


100
                                                                                                                   FHW


                                                    Basic dimensions

                                                                                                 I




                                                                                                 G


                                                                                             H




Model               A      B         C         D             E     F          G         H            I              ?
FHW12              580    525        65       340           470   60          60        60           80             18
FHW22              725    680        40       370           620   60          60        60           80             22
FHW32/33           855    820        80       450           725   70          85        60           125            28
(dimensions in mm)




                                                    Specifications




                                                    FHW12         FHW22            FHW32                   FHW33
Power                        kW                     12/17         23/30            28/50                   36/65
Voltage                         V                   230 V 1~      230 V 1~         230 V 1~                230 V 1~
Current                         A                   1.0           1.4              2.8                     2.8
Water section volume             l                  1.9           3.2              4.8                     6.5
Air consumption             m3/h                    1080/2340     1800/4070        2430/6190               2260/5710
Noise level                dB(A)                    35/49         41/52            93/60                   38/60
Weight                          kg                  25            30               40                      45
Protection index                                    IP44          IP44             IP44                    IP44
Product identification number                       2496          2497             2498                    2499
Price                       Euro                    757,0         1071,0           1326,0                  1418,0




Accessories

Additional mounting accessories (see p. 105 and p. 118)..



                                                                                                                         101
Fixed fan heaters
  FHW
 Inlet / outlet water temperature is 90/158.00 °F
                                      Inlet air temperature = -15 °C          Inlet air temperature = 32.00°F           Inlet air temperature = +15 °C
Model       Fan speed     Aircon-     Power        Airtemp.on   Watercon-    Power        Airtemp.on   Waterconsu   Power        Airtemp.on   Watercon-
                          sumption                 outlet       sumption                  outlet       mption                    outlet       sumption

                        [m3/s]        kW           °C            [l/s]        kW            °C             [l/s]        kW             °C          [l/s]
FHW12       Max.        0.65          26.5         18.4          0.31         20.8          26.3           0.24         15.1           34.1        0.18
            3           0.51          23.0         21.9          0.27         18.1          29.0           0.21         13.2           36.2        0.15
            2           0.42          20.4         24.8          0.24         16.1          31.4           0.19         11.8           37.9        0.14
            1           0.30          16.5         30.1          0.19         13.1          35.6           0.15         9.60           41.1        0.11
FHW22       Max.        1.13          47.2         19.2          0.56         37.2          27.0           0.44         27.2           34.7        0.32
            3           0.91          41.5         22.4          0.49         32.8          29.5           0.39         24.0           36.6        0.28
            2           0.64          33.4         27.8          0.39         26.5          33.9           0.31         19.4           39.9        0.23
            1           0.50          28.5         31.8          0.34         22.6          37.1           0.27         16.7           42.3        0.19
FHW32       5           1.72          69.2         18.0          1.82         54.4          25.9           0.65         39.6           33.9        0.47
            4           1.44          62.4         20.5          0.74         49.1          27.9           0.58         35.8           35.4        0.42
            3           1.03          51.0         25.5          0.60         40.2          32.0           0.47         29.4           38.4        0.35
            2           0.67          38.7         32.4          0.46         30.7          37.5           0.36         22.5           45.5        0.26
FHW33       5           1.59          89.2         31.0          1.06         70.7          36.4           0.84         52.2           41.9        0.62
            4           1.30          78.2         34.3          1.93         62.1          39.1           0.74         45.9           43.9        0.54
            3           0.88          59.8         40.7          0.71         47.6          44.4           0.56         35.4           48.0        0.42
            2           0.63          47.0         46.1          0.56         37.5          48.8           0.44         28.0           51.4        0.33

Inlet / outlet water temperature is 80/60 °C
                                      Inlet air temperature = -15 °C           Inlet air temperature = 32.00°F          Inlet air temperature = +15 °C

Model       Fan speed     Aircon-     Power        Airtemp.on    Watercon-   Power        Airtemp.on    Watercon-   Power        Airtemp.on   Watercon-
                          sumption                 outlet        sumption                 outlet        sumption                 outlet       sumption
                        [m3/s]        kW           °C            [l/s]         kW           °C              [l/s]       kW             °C          [l/s]
FHW12       Max.        0.65          30.5         23.4          0.36          24.8         31.3            0.29        19.1           39.1        0.22
            3           0.51          26.4         27.4          0.31          21.5         34.5            0.25        16.6           41.7        0.19
            2           0.42          23.4         30.7          0.27          19.1         37.3            0.22        14.8           43.8        0.17
            1           0.30          18.9         36.7          0.22          15.5         42.2            0.18        12.0           47.8        0.14
FHW22       Max.        1.13          54.2         24.3          0.64          44.2         32.0            0.52        34.2           39.8        0.40
            3           0.91          47.6         27.8          0.56          38.9         35.0            0.46        30.1           42.1        0.35
            2           0.64          38.3         34.0          0.45          31.3         40.1            0.37        24.3           46.1        0.29
            1           0.50          32.6         38.5          0.43          26.7         43.8            0.31        20.8           49.1        0.24
FHW32       5           1.72          79.6         22.9          0.95          64.8         30.9            0.77        50.0           38.8        0.59
            4           1.44          71.1         25.8          0.85          58.4         33.2            0.69        45.1           40.6        0.53
            3           1.03          58.5         29.2          0.69          47.7         37.9            0.56        36.9           44.4        0.44
            2           0.67          44.4         31.5          0.52          36.3         44.4            0.43        28.2           49.5        0.33
FHW33       5           1.59          102.0        37.5          1.21          83.5         43.0            0.99        65.0           48.5        0.77
            4           1.30          89.2         41.2          1.06          73.2         46.1            0.87        57.1           51.0        0.68
            3           0.88          68.2         48.5          0.81          56.0         52.2            0.66        43.8           55.8        0.52
            2           0.63          53.4         54.5          0.63          44.0         57.2            0.52        34.6           59.9        0.41


 Noise attributes
 Model          Fan speed Sound-pres- Sound-pres- Octave bandwidth (Hz):
                          sure level Lp sure level Lp
                          [dB(A)]       [dB(A)]
 FHW12            3           49           65            31             48            59           60     60           58         50          43
                  2           43           59            32             42            54           54     53           50         42          35
                  1           35           51            34             37            47           44     44           40         29          21
 FHW22            3           52           68            69             74            69           61     63           61         54          47
                  2           47           63            55             57            62           58     59           57         50          44
                  1           41           57            57             52            57           53     53           51         42          37
 FHW32            5           60           76            62             77            75           70     72           70         61          54
                  4           56           72            60             68            69           66     69           65         56          49
                  3           47           63            66             64            63           60     60           54         45          37
                  2           39           55            59             60            57           53     49           43         33          25
 FHW33            5           60           76            68             75            75           69     72           69         61          53
                  4           55           71            64             67            67           65     68           64         55          48
                  3           46           62            55             65            61           59     58           52         43          36
                  2           38           55            58             61            55           53     50           43         35          29
 Lw = Sound-power level, Lp = Sound-pressure level.
 LpA is calculated in the following conditions: Distance to the fan is 5 m. Directivity factor: 2.
 Equivalent absorption area: 200 m2. All tests are carried out in accordance with BS148, AMCA, 210-85 and DIN 24163 Standards.




102
                                                                                                                                                FHW
Air consumption and air throw
Model          Fanspeed         Rotational frequency Air consumption                          Air consumption *1                         Air throw *2
                                                                                              with installed
                                                                                              additional accessories
                                      [rpm]                 [m3/c]            m3/h                      [m3/c]               m3/h                       [m]
FHW12              Max.               1350                  0.65              2340                      0.47                 1700                       6.5
                   3                  1100                  0.51              1840                      0.33                 1175                       5.5
                   2                  940                   0.42              1510                      —-                   —-                         4.0
                   1                  680                   0.30              1080                      —-                   —-                         3.0
FHW22              Max.               1420                  1.13              4070                      0.67                 2400                       8.5
                   3                  1150                  0.91              3280                      0.47                 1700                       7.5
                   2                  900                   0.64              2300                      —-                   —-                         5.5
                   1                  750                   0.50              1800                      —-                   —-                         4.0
FHW32              5                  930                   1.72              6190                      1.23                 4430                       11.0
                   4                  790                   1.44              5180                      0.95                 3420                       9.0
                   3                  570                   1.03              3710                      0.61                 2210                       7.0
                   2                  390                   0.67              2430                      —-                   —-                         5.5
FHW33              5                  930                   1.59              5710                      1.19                 4270                       10.0
                   4                  775                   1.30              4680                      0.89                 3200                       8.0
                   3                  540                   0.88              3170                      0.59                 2130                       6.5
                   2                  390                   0.63              2260                      —-                   —-                         5.0
*1). With the filter section, mixing chamber and outer wall grille installed. Please note that if only the mixing unit and outer wall grille are installed, the
     decrease in air consumption is negligible.
*2). The values for the fan’s blowing range were recorded (with the horizontal directional grille with adjustable shutters installed) under the following condi-
     tions: temperature at the inlet of +40 °C and room temperature of +18 °C. The fan’s range is calculated as the distance from the air discharge aperture
     to the point, where air speed is 0.2 m/s (measured along the air flow’s direction from the fan heater).



                                                FHW water-section flow resistance




                                           Flow resistance of controllers and valves




  Flow resistance is shown for an average temperature of 70 °C (PVV 80/60).
  The flow resistance value for other water temperatures should be multiplied by the coefficient
  K.
  Mean water temperature (°C)             40       50       60         70       80       90
  Coefficient K                           1.10     1.06     1.03       1.00     0.97     0.93


                                                                                                                                                        103
Fixed fan heaters
  FHW
Assembly
The FHW fan heaters are designed and supplied with a              Electrical connection
water-heating section, fan and front shutters in a single         The device must be connected to the power circuit by a
casing. Two mounting brackets, used to mount the fan              qualified electrician, with all the relevant safety require-
heater on the wall or ceiling, must be ordered separately.        ments observed. The device is connected to the circuit via
To spread out the airflow horizontally, the fan heater is         a three-pole circuit breaker with an air gap of 3 mm.
mounted on the wall via two mounting brackets. To spread          For the FHW12 and FHW22 models the fan motor is con-
out the airflow vertically, the device is mounted onto the        nected to the cable through a terminal block, located inside
ceiling. During the installation on wall or ceiling, connecting   the casing. In FHW32 and FHW33 the feeding cable is
nozzles of the fan heater can be directed to the left or right.   attached directly to the contacts of the fan’s motor.
Do not direct them up or down.
The figure on page 105 shows the recommended installa-            Power and airflow control
tion.                                                             The standard FHW12 and FHW22 models enable the selec-
                                                                  tion of the desired speed setting (see electric circuits on
Wall mounting                                                     page 106 - 107). The motors of FHW32 and FHW33 mod-
When mounting the fan on the wall, the locations of neces-        els have a single speed setting.
sary holes must be marked on the wall. To install the             To regulate the airflow speed, use the 3-step speed con-
mounting brackets onto the fan heater, use the screws             trollers (FHWR3 and FHWR3A) and RE or RE7 transform-
supplied. Please note that the strength characteristics of        ers.
the wall and the screws attaching the mounting brackets to        The temperature is regulated by the SR121, SR122 or RT
the wall must be suitable for the selected method of instal-      0-30 thermostats.
lation.                                                           The supply and consumption of water is regulated by the
The FHWMC mixing unit and / or the FHWFFHWF filter                following accessories: FHWSV20/25 (stop valves),
section are attached to the fan heater by screws. The actu-       FHWAV20/25 (control valves), FHW2RV20/25 (2-way control
ator’s motor is fixed on the axle of the mixing chamber’s         valves) and FHWACT (electric actuator for the water-control
damper.                                                           valve).
When using the fan heater with only a filter section (without
a mixing chamber), an FHWDrecirculation section must be
used..
To connect the air duct to the mixing chamber - disconnect
the three screws holding the round protection grille and
connect the air duct.
To increase the rigidity of the entire construction, use the
necessary supports and tension bars etc, with their proper
attachment to the wall or ceiling.
Please note that all accessory casings are supplied coated
with varnish.

To protect the FHW air-heating section, it could be
equipped withFHWFNcoarse-mesh filter which is supplied
separately. It is applied if the FHWF filter section is not
used. For its installation, the front and back panels are
removed and the filter is placed before the heat coil on
special guides.

To shift the air flow sideways, additional FHWADshutters
must be used. The basic design of the fan heater only
includes up-down directing air shutters. The FHWAD sec-
tion is mounted on top of the standard shutters and is fixed
with screws.

Ceiling mounting
Ceiling mounting is performed in a similar way to wall
mounting. When an FHW fan heater is equipped with filter
and recirculation sections, they are attached to one anoth-
er and then the entire device is mounted on the ceiling.
The holding capacity of the ceiling and beam material, as
well as the characteristics of the mounting fixtures, must be
appropriate for this method of installation.
Provision must be made for drainage and air removal
valves. The air valve is located in the top and drain valve is
located at the bottom of the casing. They are mounted out-
side the FHW and do not come supplied. If there is a dan-
ger of the hot water coil freezing over (such as during the
operating of the mixing chamber in winter), special external
protective automation should be installed.

104
                                                                                        FHW

                                   FHW fan heater assembly




          FHWFN                                FHWC




                                                                                  FHWWG




                                                                    FHWMC



                                            FHWF

                                                             FHWD


FHWAD             FHW Fan heater




 Model            Title                                 Product identification number Price
 FHWMC1           FHW12 Mixing chamber                              10780          336,00
 FHWMC2           FHW22 Mixing chamber                              10781          427,00
 FHWMC3           FHW32/33 Mixing chamber                           10782          512,00

 FHWD1            FHW12 Recirculation air section                   10783          79,00
 FHWD2            FHW22 Recirculation air section                   10784          97,00
 FHWD3            FHW32/33 Recirculation air section                10785          109,00

 FHWF1            FHW12 Filter section                              10786          328,00
 FHWF2            FHW22 Filter section                              10787          407,00
 FHWF3            FHW32/33 Filter section                           10788          511,00

 FHWFN1           FHW12 Wire mesh filter                            10789          106,00
 FHWFN2           FHW22 Wire mesh filter                            10790          121,00
 FHWFN3           FHW32/33 Wire mesh filter                         10791          146,00

 FHWC1            FHW12 Brackets (2-piece set)                      10792          66,00
 FHWC2            FHW22 Brackets (2-piece set)                      10793          69,00
 FHWC3            FHW32/33 Brackets (2-piece set)                   10794          86,00

 FHWAD1           FHW12 Air distribution grille                     10795          146,00
 FHWAD2           FHW22 Air distribution grille                     10796          177,00
 FHWAD3           FHW32/33 Air distribution grille                  10797          213,00

 FHWWG1           FHW12 Outer wall grille                           10800          125,00
 FHWWG2           FHW22 Outer wall grille                           10801          165,00
 FHWWG3           FHW32/33 Outer wall grille                        10802          213,00

 FHWEF1           EU3 extra filter 1                                10890          52,00
 FHWEF2           EU3 extra filter 2                                10891          64,00
 FHWEF3           EU3 extra filter 3                                10892          70,00


                                                                                              105
Fixed fan heaters
 FHW

                                                                       FHW 12/22 Electric circuits

      Fan speed is preselected; no adjustment is performed
       The jumpers are removed: the fan is                                                                                                  Jumper configuration for the average
       fixed in the No. 1 position (low speed)                                                                                              fan speed (No. 2 position)



                                                                                                                                                                     1 2 3 4         5 6 7 8 9 N
                                  M                 c˚
                                  ~
                           2
                                        Brown
                                        Black

                                        Blue




                                                                                                                                                                                            L1 N (L2)
                           3                                                            FHW condenser parameters                                                                            230 V~
                                             1                                          FHW12                        FHW22
                                        4
                                                                                1          2    3      4          1     2    3    4                                  1 2 3 4         5 6 7 8 9 N
                   1 2 3 4                  5 6 7 8 9 N
                                                                              4 mF       8 mF 2 mF   2 mF       16 mF 8 mF 1 mF 3 mF


                                                                                                                                                                                            L1 N (L2)
                                                         L1 N (L2)
                                                                                                                                                                                            230 V~
                                                         230 V~




                      Automatic temperature                                                                         SR121 (IP55) Thermostat and 3-step
                       regulator (FHWR3A)                                                                                    regulator (FHWR3)


                 1 2 3 4          5 6 7 8 9 N
  FHW12/22                                                                                                                                                  1 2 3 4              5 6 7 8 9 N
                                                                                                                                       FHW12/22
                                                                                  FHWACT
                                                                                                            FHWACT
                 1 2 3 4          5 6 7 8 9 N
  FHW12/22
                                                                              FHW2RV20/25
                                                                                                            FHW2RV20/25                                     1 2 3 4              5 6 7 8 9 N
                                                                                                                                       FHW12/22

                                                                                                                     1
                                                                                                                     2
                                                                        6                                            3
                                                                        5         Hi°
                 1 2 3 4        5 6               L N                   4                                                                                     2 4 6

                                                                                        1                   SR121                                             1 3 5
                                                                            Lo°
                                                                                        2                                                   FHWR3
                                                                                        3

                                                                            Diff 2K
                 1 - 2 - 3 Man - Auto
                                                         FHWR3A        SR122

                                                 L1 N (L2)                                                                 L1 N (L2)
                                                 230 V~                                                                    230 V~




             RT 0 - 30 (IP30) Thermostat and                                                                               3-step regulator (FHWR3)
                3-step regulator (FHWR3)                                                                                  with night-time function and
                                                                                                                           electron relay (REX 2000)


                                                             1 2 3 4   5 6 7 8 9 N
                                            FHW12/22
  FHWACT
                                                                                                                                              1 2 3 4          5 6 7 8 9 N
                                                                                                                                 FHW12/22
                                                                                                                                                                                                         FHW
                                                             1 2 3 4   5 6 7 8 9 N
  FHW2RV20/25                               FHW12/22
                                                                                                                                              1 2 3 4          5 6 7 8 9 N
                                                                                                                                 FHW12/22
                                                                                                                                                                                                     FHW
             2
             1
             5
             4
             3                                               2 4 6                                                                                                                             6
                                                                                                                                                                                               5         Hi°
                                                             1 3 5                                                                            1 2 3 4        5 6          L N                  4

  RT 0-30                                   FHWR3
                                                                                                                                                                                                   Lo°



                                                                                                                                                                                                   Diff 2K
                                                                                                                                              1 - 2 - 3 Man - Auto
                                                                                                                                                                                FHWR3A         SR122
                        L1 N (L2)
                        230 V~                                                                                                                                           L1 N (L2)
                                                                                                                                                                         230 V~




106
                                                                                                                                                           FHW

                                                                    FHW 32/33 Electric circuits

                                                                                  5-step regulator (with RE3 or RE7) with night-
       Fan speed is maximal, adjustment                                          time function and MicroRex D21 Plus electronic
               is not performed                                                                     time relay
                                                                                                                                   Z2 Z1 U2 U1 TK TK
                                                                                                                   FHW32/33
                                                                                                FHWACT
                                                                                                                                       Z2 Z1 U2 U1 TK TK
                                                                                                                   FHW32/33

                                           c˚    M                                              FHW2RV20/25
                                                 ~
                       Orange




                                                                                            2
                                Brown
                                Black




                                                                                  Temp 1    1
                                Blue




                                                                                            5
                                                                                            4
                                                                                            3
                                                                                                                                            L1 L2          ~   NN   ~
                                                                                                              4
                                                                                                              2                RE3/7
                                                                                  RT 0-30
                                                                                                              1
                                                                                            2
                                                                                  Temp 2
                         Z2 Z1 U2 U1 TK TK                                                  1                 L
                                                                                            5                 N
                                                                                            4
                                                                                            3            REX2000

                                     N (L2)   L1
                                                                                  RT 0-30
                                        230 V~
                                                                                                                   L1 N (L2)
                                                                                                                   230 V~




Thermostat SR121 (IP54) and 5-step regulator
               (RE3 or RE7)

                                                Z2 Z1 U2 U1 TK TK
                                FHW32/33
    FHWACT
                                                Z2 Z1 U2 U1 TK TK
                                FHW32/33
    FHW2RV20/25

             1
             2
             3
                                                     L1 L2          ~   NN   ~
     SR121                             RE3/7



                  L1 N (L2)
                  230 V~




                                                                                                                                                                    107
Fixed fan heaters
  FHC



      !
   New




                                                                                                                  Водяной
                                                                                                                   нагрев




      Advantages

      •   compact fixed fan heater
      •   corrosion-proof steel casing
      •   overheating protection
      •   ceiling or wall mounting
      •   two fan speeds




Recommended application                                         Assembly
FHC is a series of fixed fan heaters with a water-based air-    Both ceiling and wall mounting is possible. To supply the air
heating element. They are designed for warehouses, pro-         top-down, the FHC fan heaters are mounted directly to the
duction facilities, halls of various buildings, shops etc.      ceiling or hung on mounting brackets. Installation into a
FHC is very effective and easy to install. The fans are         false ceiling is also possible. To supply air horizontally, FHC
designed to be installed on the ceiling, but wall mounting is   is mounted on the wall.
also an option.
                                                                Certificates
Construction                                                    Certificate of Conformity of the Russian Federation,
Fan heaters are made from corrosion-proof steel. The cas-       Ukraine, SEMKO and CE Standard.
ing of the device is coated with white powder paint. The
model comes in three standard sizes.


Speed control
It is recommended to use external control equipment.
The air temperature is regulated via electronic thermostats:
RT 0 - 30 or SR121. RT 0 - 30 electronic thermostat is
mounted on the wall and has an inbuilt thermal sensor. The
SR 121 single-step thermostat has an on / off function and
an external round handle (with control functions).
It is recommended to use the FHWR3A controller to regu-
late the speed. The fan has two speed settings.
The FHWACT electrical actuator is used to regulate the
water circuit.




108
                                                                                                                                     FHC

                                                       Basic dimensions


                                                                                                                      C                   F
                                                                                                                                              M
  18




                                                                     G

                                                                             H




                                                                                                  D
                                                                                         E


                                                                                                      B
                                                                    K
                                øL
                                                                                                                                      ø12
                                                                                                                          A




    Model                 A           B         C        D               E       F            G           H     K             ?L          M
    FHC 10              695           570     450       600         630          180      195             320   130           310     R1/2
    FHC 20              895           620     650       650         680          180      195             350   155           345     R1/2
    FHC 40              1062          700     850       730         760          145      290             400   110           435     R1/2




                                                                Specifications


                                                               FHC 10                             FHC 20                  FHC 40
   Power                         kW
   Voltage                         V                           230 V 1~                           230 V 1~                    230 V 1~
   Current                         A                           0.4                                0.6                         1.0
   Air consumption             m3/h                            700/1100                           1300/2000                   2500/3900
   Noise level                dB(A)                            37/53                              44/57                       48/60
   Weight                         kg                           21                                                             28 42
   Protection index                                            IP44                               IP44                        IP44
   Product identification number                               4772                               4773                        4774
   Price                        Euro                           1020,0                             1190,0                      1690,0



  If the ceiling is very high, a special FHCE extension piece is used to increase the range of the air discharge.:
   Title                         Product identification number               Price
   FHCE                          4775             80,0
   FHCE                          4776             91,0
   FHCE                          4777             132,0




 Accessories




    RT 0 - 30        SR Thermostat,   FHWR3A regula-   FHWACT valve          FHCE extension
Thermostat, p. 117       p. 117         tor, p. 118    actuator, p.118        piece, p. 109


                                                                                                                                              109
Fixed fan heaters
   FHC



                                                                     FHC 10 output


                           Temp. on the inlet / outlet 55/45 °C     Temp. on the inlet / outlet 60/40 °C      Temp. on the inlet / outlet 80/60          °C
Airconsump- Airtemp.on Output Airtemp.on Watercon- Differenceof Output    Airtemp.on Watercon- Differenceof Output [kW] Airtemp.on Watercon-             Differenceof
tion,(m3/h) outlet     [kW]    outlet       sumption water pres- [kW]     outlet        sumption water pres-            outlet      sumption             water pres-
                                            [l/s]        sure [kPa]                     [l/s]      sure [kPa]                       [l/s]                sure [kPa]

700         +10         6,3         35,8         0,15      4           5,3       31,8         0,06     1            9,5      48,9          0,13      2
1100        +10         8,3         31,6         0,20      6           7,3       29,1         0,09     1            12,5     42,5          0,15      3
700         +15         5,4         37,6         0,13      3           4,3       33,0         0,05     1            8,6      50,8          0,10      2
1100        +15         7,1         33,9         0,17      5           5,8       30,5         0,07     1            11,3     44,9          0,14      3
700         +20         4,6         39,3         0,11      2           3,4       34,3         0,04     0,5          7,7      52,6          0,09      1
1100        +20         6,0         36,1         0,14      3           4,4       31,9         0,05     1            10,1     47,3          0,12      2




                                                                     FHC 20 output

                              Temp. on the inlet / outlet 55/45 °C      Temp. on the inlet / outlet 60/40 °C       Temp. on the inlet / outlet 80/60 °C
Aircon-     Airtemp. Output      Airtemp.on Watercon- Differenceof Output   Airtemp.on Watercon- Differenceof Output     Airtemp.on Watercon- Differenceof
sumption,   on outlet [kW]       outlet      sumption water pres- [kW]      outlet      sumption water pres- [kW]        outlet        sumption water pres-
(m3/h)                                       [l/s]        sure [kPa]                    [l/s]        sure [kPa]                        [l/s]       sure [kPa]

1300        +10         10,8        33,8         0,26      12          10,2      32,5         0,12     3            16,2     45,9          0,20      7
2000        +10         13,9        29,9         0,33      18          13,0      28,6         0,16     5            20,9     39,9          0,25      10
1300        +15         9,3         35,9         0,22      9           8,7       34,5         0,11     2            14,7     48,1          0,18      5
2000        +15         12,0        32,5         0,29      14          11,0      31,1         0,13     4            18,9     42,6          0,23      9
1300        +20         7,8         37,9         0,19      7           6,9       35,7         0,08     2            13,2     50,2          0,16      5
2000        +20         10,1        35,0         0,24      10          9,1       33,6         0,11     3            17,0     45,2          0,21      7




                                                                     FHC 40 output

                              Temp. on the inlet / outlet 55/45 °C       Temp. on the inlet / outlet 60/40 °C         Temp. on the inlet / outlet 80/60 °C
Aircon-     Airtemp.on Output      Airtemp.on   Watercon- Differenceof Output   Airtemp.on   Watercon- Differenceof Output Airtemp.on   Watercon- Differenceof
sumption,   outlet     [kW]        outlet       sumption water pres- [kW]       outlet       sumption water pres- [kW] outlet           sumption water pres-
(m3/h)                                          [l/s]     sure [kPa]                         [l/s]     sure [kPa]                       [l/s]     sure [kPa]

2500        +10         21,3        34,5         0,51      11          20,2      33,2         0,24     3            32,1     46,9          0,39      6
3900        +10         27,7        30,4         0,67      17          26,0      29,1         0,31     4            41,7     40,7          0,51      10
2500        +15         18,4        36,5         0,44      8           17,3      35,2         0,21     2            29,2     49,1          0,36      5
3900        +15         23,9        32,9         0,58      13          22,2      31,6         0,27     3            37,8     43,3          0,46      8
2500        +20         15,5        38,5         0,38      6           13,6      36,2         0,16     1            26,2     51,1          0,32      4
3900        +20         20,2        35,4         0,49      10          18,4      34,0         0,22     2            34,0     45,9          0,41      7




110
Accessories for Systemair air curtains and fan heaters




                                                    111
Accessories for air curtains and fan heaters



Air curtain adjustment
The operation of the air curtains are regulated by control systems, specifically designed to create the most comfortable
conditions with minimal energy consumption.

Systemair’s Portier Mini and AS air curtain models do not require additional regulating devices. Portier Mini (for small door-
ways) has an inbuilt thermostat and control panel. AS models do not have a heating element and are supplied with
mounting brackets, power cord and a plug.
For all other Systemair curtain models the necessary regulating devices are supplied as accessories.
This allows the client to choose the optimal set of controlling devices to suit his / her personal demands and the specific
conditions of the premises in question.
The speed and power level of the heat curtains can be regulated.

Airflow velocity control
In most cases a simple two- or three-step control panel is used to regulate the air velocity of the air curtains. Sometimes it
is more convenient to use controllers with a continuous range of speed settings.
The MP control panels are used to regulate the speed of models belonging to the LG, Portier Basic / Portier Basic Design
and Portier Grand / Portier Grand Design series. HDR speed controllers are designed for HD and HF air curtains.
Usually an HDR controller is used together with an HDGL gate status sensor, which significantly helps to save energy. It
is installed with the curtains from the industrial series (HD, HF and MTV) and with curtains from the PG series.

The airflow speed of MTV curtains is regulated by the REU and RE transformers. It is also possible to use an REE thyristor
to set the fan speed and air consumption (in MTV curtains).

Power level control
Curtains of LG, Portier Basic / Portier Basic Design and Portier Grand / Portier Grand Design series are most often operat-
ed via the MP22, MP32 and MP-I control panels.They allow the regulation not only of airflow velocity, but of heating
power as well. An HDEV power level controller can be used with models of the HD and HF series.
An SR12 thermostat is suitable for all air curtain models requiring additional regulating devices, with the exception of MTV
models. If the air curtains are installed in industrial facilities or have to operate under strict conditions, SR122 is used. This
thermostat is similar to SR12, but offers a higher level of protection. The MTV air curtains do not need power level con-
trollers, because they do not have a heating element. Nonetheless the model is able to provide a heating effect by force-
fully recirculating air into the work zone.

Stop and control valves
Stop and control valves must be installed on curtains with a water-based air-heating section from the LGW, PGW, HFW
and HDW series. An FHWSV20/25 ball valve is used to turn the hot water supply on and off. The water consumption rate
is regulated by the FHWAV20/25 balancing valve or an FHW2RV 2-way valve. The FHW2RV valve, FHWACT electrical
actuator and a thermostat make the minimal set of equipment needed to control the hot water consumption in terms of
the air temperature inside the premises, as set on the thermostat.




112
General information on fan heater control
The Systemair fan heateroperation is controlled by thermostats and regulators.

Temperature control with thermostats
The simplest and affordable method of maintaining the desired temperature in a room is by means of a so-called, two-
position thermostat, which measures the air temperature and shuts the heating element on and off, in accordance with
the selected temperature.
Thermostats offered by Systemair come equipped with an inbuilt temperature sensor, which sends its readings to the cur-
tain’s control device. However, if need be, an additional TG-K330 or TG-R630 external sensor can be installed.

One of the most important features of a thermostat is the presence of temperature differential operation (temperature
hysteresis). A thermostat, which switches on at 24 °C and off at 25 °C has a 1 °C differential. This index is crucial to stabi-
lizing the process of temperature regulation.
In order to avoid significant air temperature fluctuations, the temperature differential must no be too great.
When the heating elements are regulated by means of contactors, a very small differential will cause a frequent switching
on and off, leading to faster degradation of the contactors and an excessive noise level at the premises.

Capillary and electronic thermostats
There are several types of thermostats. Thermostats equipped with a capillary tube work on the principle of thermal
expansion of a fluid. Such thermostats have suitable accuracy and are not very expensive. In most cases they provide a
sufficient regulation of air temperature at the premises.
Electronic thermostats are more expensive, but have two important advantages. They allow the setting of the desired
temperature and regulate the temperature differential with high precision.

Both the SR121 capillary and RT 0 - 30 electronic thermostats are designed to maintain a set temperature by controlling
a motor with a single power setting. The difference between them is that RT 0 - 30 operates from a 230 V power circuit,
while SR121 does not need electricity to operate. On top of that, an electronic thermostat has a lower level of protection
than SR121. This makes an electronic thermostat unsuitable for most warehouses and premises with a polluted environ-
ment.

The SR122 multi-stage thermostat is often used at industrial premises. It regulates the two speed settings of the fan. For
highly powerful heating systems, it is often impractical to simply switch full power on and off. It is far better to break the
fan heater’s total functional capacity down into 2 or more fractions and deploy them in a progressive manner when
needed. This method allows some of the load to be taken off the circuit, while maintaining significant heating power.

Air consumption and temperature control
Systemair recommends using the FHWR3A and FHWR3 three-step regulators to control the air consumption of a fan
heater. These devices can control up to 6 fan heaters. In order to control the heating a thermostat, a system of valves or
a FHW2RV two-way valve and an FHWACT valve actuator must be installed.

RE series five-step transformers are used to regulate the air consumption of Systemair fan heaters. They are designed to
manually regulate the air consumption of one or two hot-water-based fan heaters. To successfully control the air tempera-
ture, a thermostat and a system of valves or a two-way valve and a valve actuator must be used together with an RE
transformer. a thermostat and a system of valves or a two-way valve and a valve actuator must be used together with an
RE transformer.

Regulating the water consumption rate with a thermostat
To regulate the water consumption rate in Systemair fan heaters, the following components must be installed: an FHW2RV
two-way valve (or a system of valves) and an FHWACT valve actuator. A thermostat (such as RT 0 - 30 or SR121, 122) is
needed to operate the FHW2RC valve with an FHWACT actuator.
To simplify the set up and technical servicing of the water consumption in the system, stop and control valves can be
installed. An FHWSV stop valve can be used to cut off the water supply to the heating coil during technical servicing of
the device, while the FHWAV control valve is used to limit the water consumption if pressure in the hot water circuit
becomes too high.




                                                                                                                            113
Accessories for air curtains and fan heaters



MR Control panel




      MP22                MP32             MP-I                         MP20            MP30               MP0-I
MP22 – a control panel for models in the LG and Portier         velocity switch. A single control panel can operate up to 4
series with an electrical heating element. MP22 has two         LG air curtains (limited by maximum current).
switches - one to regulate the air consumption and other to
                                                                Max. current               12 A
regulate the electrical air heating element. MP22 has two
                                                                Casing protection index    IP 44
speeds and two heating power levels. A single control
panel can regulate several curtains (limited by maximum
                                                                MP30 – a three-step control panel for air curtain models in
current).
                                                                the LG and Portier series with no heating element or a hot-
Max. current               10 A                                 water coil heater. MP30 has a single air-consumption
Casing protection index    IP 44                                velocity switch. A single control panel can regulate several
                                                                curtains (limited by maximum current).
MP32 – a control panel for models in the LG and Portier
                                                                Max. current                 10 A
series with an electrical heating element. It performs a
                                                                Casing protection index     IP 44
three-step air velocity control and a two-step heating power
regulation. MP32 has two switches - one to regulate the air
                                                                MP0-I – a two-step control panel for air curtain models in
consumption and other to regulate the electrical air heating
                                                                the LG and Portier series with no heating element or a hot-
element. A single control panel can regulate several cur-
                                                                water coil heater. MP0-I is built into the curtain and has a
tains (limited by maximum current).
                                                                single airflow velocity switch. A single control panel can
Max. current               10 A                                 regulate several curtains (limited by maximum current).
Casing protection index    IP 44
                                                                Max. current           5A
MP-I – a built-in control panel for LG and Portier curtains     Casing protection index     IP 44
with an electrical heating element. MP-I has two switches
and performs a two-step air velocity and power level con-
trol. A single control panel can regulate several curtains
(limited by maximum current).
Max. current                 5A                                 Model            Product identification number         Price
Casing protection index     IP 44                               MP22                         1188                      99,0
                                                                MP20                         1201                      88,0
MP20 – a two-step control panel for air curtain models in       MP32                         1140                      99,0
the LG and Portier series with no heating element or a hot-     MP30                         1130                      88,0
water coil heater. MP20 has a single air-consumption            MPI                          8203                      94,0
                                                                MP0I                         8202                      83,0

HDR4 Speed control
                HDR4 — - a five-position cam-type               Positions             0-1-2-3-4
                switch. Designed to regulate the fan            Max. current          20 A, 3 kW (230 V 1~)
                speeds of all HD air curtain models. A sin-     Protection index      IP65
                gle HDR4 can regulate up to 14 fans.            Dimensions (mm)       80 x 100 x 90
                Standard HD curtains have two fans, while
                the longer models (HD0L and etc.) have
three. Each motor consumes 0.2 kW of power and works
at a 230 V voltage 1~.                                          Model            Product identification number         Price
                                                                HDR4                         8060                      52,0

HDR42 Speed control
              The speed regulator is designed to operate
              all air curtains in the HD series. It activates   Positions                    0 - 1 - 2 - 3 - 4 (x 2)
              one of the two fan speeds, depending on           Max. current                 20A
              whether the doorway is open or closed. The        Max. current                 IP65
              HDGL gate status sensor activates one of          Dimensions                   80 x 100 x 90
              two HDR42 working elements. To make the
              curtain switch off, when the doorway is
closed, one of the turning handles must be set to the zero      Model            Product identification number Price
position.                                                       HDR42                        8994              182,0

114
                                                                                                    HDEV Power controller
                HDEV — - 3-position power controller. It is       Protection index             IP65
                designed to regulate the fan speed of HD          Dimensions (mm)              80 x 100 x 90
                air curtains with electrical heating element.

                Positions 0 - 1 - 2                               Model                 Product identification number               Price
                Max. current        20A                           HDEV                              8061                            48,0


                                                                                            S-ET10 Thermal protector
                                  S-ET 10E (for installation on                                          S-ET 10E                  S-ET 10
                                  the mounting rail) ) and S-     Voltage (V)                                60 230                60 230
                                  ET 10 (for wall mounting)
                                                                  Current min. / max. (A)                    0,4/10                0,4/10
                                  switch off the motor’s power
                                  supply when a thermal con-      Circuit breaker (A)                        16                    16
                                  tact in the motor winding       Weight (kg)                                0,3                   0,5
                                  activates. The thermal pro-     Dimensions (W x H x L) (mm)                63 x 80 x 76          79 x 141 x 80
tection device is attached to the power supply and to the         Ambient temperature (°C)                   25 to +60             25 to +40
thermal contact of the motor.
                                                                  Protection index                           IP 20                 IP 54
If the thermal protection is activated, the motor can be
restarted by pressing a black button, after the motor cools       Product identification number              5155                  5154
down. The motor thermal protection device can be used in          Price                                      67,0                  68,0
conjunction with a transformer.
S-ET has another dry contact to send of an external signal,
once the contacts are activated.
A warning alarm contact (?) is supplied separately. It is an
inbuilt dry contact, which sends a signal upon thermal con-                          Dry contact for warn-
tact disconnection.                                                                  ing alarm



                                                                                                                            A warning alarm con-
                                                                                                                            tact (?) is supplied
                                                                                                                            separately.


                                                                                          Condenser


                                                                  REU1.5, REU3, REU5, REU7 transformer
               REU – a five-step, single-phase transformer,                                Current    Circuit breaker         Protection index
               operating the five speeds of the fan by alter-
                                                                  REU 1,5                   1.5 A             1.8 A                 IP 54
               ing the supplied voltage. The speed is manu-
               ally selected by switches on the casing: one       REU 3                       3A              3.5 A                 IP 54
               for high fan rotation speed and one for low.       REU 5                       5A               6A                   IP 54
               The fan speed modes (high and low) are
               switched automatically by means of an exter-       REU 7                       7A               8A                   IP 54
nal device (thermostat, timer or, for example, an HDGL
gate status sensor).                                                       Dimensions (W x H x L) [mm] WeightProduct identification
The front transformer panel is equipped with a running            number                 Price
lamp.
                                                                  REU 1.5       105 x 200 x 105                   1.7 kg      5004         157,0
The automatic resetting circuit breaker can be returned to
its original position externally. The transformer has a safety    REU 3         105 x 275 x 145                   3.2 kg      5005         251,0
device which can be restarted manually by pressing a but-         REU 5         105 x 275 x 145                   4.8 kg      5006         292,0
ton on the casing.
REU casing is made from nonflammable thermoplastic.               REU 7         105 x 275 x 145                   7.7 kg      5007         385,0
                                                                                                                      External switch 1
Power supply parameters: 230 V, 50/60 Hz                                                                              (230 V)
ATTENTION!Fans with external thermal contacts (TK) must
be attached to the motor’s thermal protection device.

Output voltage for a switch position:
Positioning            1      2        3         4       5
Voltage (V)           80     105      130       160     230
                                                                                          M
                                                                                      1 x 230 V



                                                                                                                                            115
Accessories for air curtains and fan heaters




 RE1.5, RE3, RE5, RE7 transformer
             RE - step transformer with manual control
                                                                    CurrentCircuit breaker   Protection index
             A single-phase transformer which regulates
             fan speed by changing the supplied voltage             RE1.5              1.5 A      1.8 A                           IP   54
             (five steps). It can operate several motors, if        RE3                 3A        3.5 A                           IP   54
             their combined current does not exceed the             RE5                 5A         6A                             IP   54
             nominal current of the transformer. The speed          RE7                 7A         8A                             IP   54
             is manually selected by switches on the cas-
             ing: The indicator lamp on the front panel
shows whether the transformer is in operation.
The transformer has a safety device and, if activated, it can        Dimensions (W x H x L) (mm)            WeightProduct identification number      Price
be restarted manually by a button on the casing. The trans-          RE1.5       105   x   200   x   105         1.5   kg       5000        116,0
former has a 230 V power outlet to activate the dampers              RE3         105   x   200   x   105         2.5   kg       5001        154,0
and other devices. When the transformer switch is set to             RE5         105   x   200   x   105         4.1   kg       5002        179,0
zero, no power is supplied to that outlet. RE casing is
                                                                     RE7         105   x   275   x   145         7.5   kg       5003        268,0
made from nonflammable thermoplastic.
Supplied voltage 230 V, 50/60 Hz.

ATTENTION! Fans with thermal contacts (??) outlets must
be attached to the motor’s external thermal protection
device.

Positioning           1         2       3        4        5
Voltage (V)           80       105     130      160      230


                                                                                                        M              Power supply 230 V
                                                                                                 1 x 230 V


                                                                    When the handle is in one of the 1 - 5 positions, the outlet
                                                                    contacts have 230 V supplied to them.




REE 1, REE 2, REE 4 Thyristor
                REE - Thyristor speed control - for surface                                      REE 1            REE 2           REE 4
                and flush-mounting.
                                                                   Voltage (V)                   230               230             230
                REE – a single-phase thyristor control which
                manually regulates fan speed and air con-          Frequency (Hz)                50                50              50
                sumption.                                          Operating current (A)         0.1 to 1.0        0.1 to 2.0      0.4 to 4.0
                It can operate several motors, if their com-       Circuit breaker               F 1.25/250        F 2.5/250       F 5.0/250
bined current does not exceed the nominal current of the           Protection index              IP 54             IP 54           IP 54
thyristor regulator. When selecting a standard size of thyris-
                                                                   Dimensions (W x H x L) [mm]                     82 x 82 x 65    82 x 82 x 65 82 x 82 x 65
tor, account should be made of the value of the starting
current.                                                           Weight (kg)                   0,26              0,255           0,286
A thyristor control mounted on the surface of the casing           Color                         white             white           white
has an IP54 Protection index. If it is flush mounted without a     Product identification number                   5314            5316             5317
casing, its Protection index is IP44, which allows its installa-
                                                                   Price                         46,0              55,0            125,0
tion in bathrooms etc. Fans, regulated by this controller,
must have a thermal protection device and allow their
speed to be changed by altering the power supply voltage.
The transformer has a 230 V power outlet to activate the
dampers and other equipment.

ATTENTION! A thyristor control in operation can lead to
additional noise in he fan motor!




116
                                                                     SR12, 121, 122 Electronic thermostat



                                    SR12 (122)                                   SR121


SR12 – 2-position electronic thermostat equipped with an          Working range           0 - 40 °C
external regulator It is connected to the MP and HDEV con-        Response characteristic, DT        1.5 °C
trol panels to operate the air heating of curtains in the LG,     Max. load             10/16 A, 230/400 V
Portier, HD and HF series. Casing protection level is IP44.       Casing protection level   IP44 (SR12)
                                                                                                     IP55 (SR121, SR122)
SR121 - single-step electronic thermostat with on / off
function. Equipped with external round handle (with control
functions).
                                                                  Model              Product identification number Price
SR122 - an electronic thermostat similar to SR12, but rec-        SR12                           1120              114,0
ommended for use in industrial premises and areas with            SR121                          8070              114,0
severe operating conditions (IP55).                               SR122                          8073              119,0


                                                                                                   RT 0 - 30 Thermostat
            RT 0-30 - 0 30 - an indoor electronic ther-
            mostat designed for heating and cooling con-
            trol. Designed for indoor wall installation. It is
            equipped with a built-in thermal sensor, but it
            can also be connected to an external thermal
sensor, such as TGK330 or TGR630.
RT 030 could be equipped with a 6-step control switch,
which allows it to be used in conjunction with the TGR600
sensor to control the air temperature from 30 to +30 °C.
A wheel with a different scale is included in the set.



                                              RT 0-30                                                External
                                                                               External sensor       sensor
Voltage                         VAC           230±15%
Mains frequency                  Hz           50/60
Relay                             A           16, 230 VAC                          In-build sen-
Setting                          °C           0 30                                 sor
Dimensions (W x H x L)          mm            86 x 86 x 30
Protection index                              IP 30
Product identification number                 5151
Price                                         32,0



                                                                                           MicroRex D21 Plus Timer
                                                                                                         MicroRex Plus
                   MicroRex D21 Plus - a digital weekly
                   timer with 28 programmed operating            230 V, 50/60 Hz                         230
                   regimes. Each program sets the time and       Power input (W)                         1...1,5
                   date of device’s switching on and off. The    Contact                                 1 contact switch.
                   timer is designed for wall mounting.          Switching rating of the contact         16 ?/250 V (cos = 1)
                                                                 Movement accuracy                       +/ 1 s/24 h
                                                                 Number of programs                      28
                                                                 Ambient temperature (°C)                -20 to +55
                                                                 Product identification number                 9800
                                                                 Price                                         190.0




                                                                                                                           117
Accessories for air curtains and fan heaters




FHWR3, FHWR3A, Speed control
             FHWR3 and FHWR3A - 3-step speed con-
             trol. Used for FHW fixed fan heaters.               Model             Product identification number Price
                                                                 FHWR3                        10798               50,0
                                                                 FHWR3A                       10799              220,0



FHWACT, Actuator 20/25
                 FHWACT - 20/25 actuator of FHW2RV              water-circuit control device, fixed fan heaters of the
                 valve. Designed to open and close the          FHWACT series, as well as with air curtains with a hot-water
                 valve, upon the command of the thermo-         coil of the LGW, HDW, PGW, PGDW and HFW series.
                 stat. It takes 5 seconds to fully open the
                 valve, to avoid pressure spikes.               Model             Product identification number     Price
                 Protection index is IP40. By way of a          FHWACT                       10803                  87,0


FHW2RV, two-way valve
                 FHW2RV20 and FHW2RW25 - two-way                kv value has three installation options:
                 control valves. valve dimensions:
                 FHW2RV20 - DN20 (3/4”) and FHW2RV25                               Pos. 1         Pos. 2        Pos. 3
                 - DN25 (1’). Pressure number PN16.             FHW2RV20           kv 1.6         kv 2.5        kv 3.5
                 Permissible pressure 2 MPa (20 bar).           FHW2RV25           kv 2.5         kv 4.0        kv 5.5
                 FHW2RV20 Maximal pressure difference:
100 kPa (0.1 bar). FHW2RV25 Maximal pressure differ-
ence: 62 kPa (0.062 bar).                                       Model             Product identification number     Price
FHW2RV valves are used for FHW fixed fan heaters, as well       FHW2RV20                     10804                  51,0
as for LGW, PGW, PGDW, HDW and HFW air curtains with            FHW2RV25                     10805                  89,0
a water-based air heater.


FHWAV, control valve
                     FHWAV20 and FHWAV25 - control              within the 0.13 - 5.9 range, while the FHWAV25 is within the
                     valve for fine adjustment of water         0.17 - 8.52 range. The FHW2RV valves are used for fixed
                     consumption. It can be used to             fan heaters of the FHW series, as well as for the air curtains
                     measure the water consumption              of the LGW, HDW, PGW, PGDW and HFW series with a
                     and is equipped with nipples for           water-based heating element.
                                                                Model             Product identification number Price
                     attaching a series of manometers.
                                                                FHWAV20                       10806               182,0
                     kv value of the FHWAV20 valve is           FHWAV25                       10807               204,0

FHWSV, Stop valve
                       FHWSV20 and FHWSV25 - ball               as for LGW, PGW, PGDW, HDW and HFW air curtains with
                       stop valves; operating mode -            a water-based air heater.
                       open / close. The valves are used
                       for switching the main hot-water
                       supply on and off. The water sup-
                       ply is gauged by a control valve,        Model              Product identification number    Price
and can be completely shut-off by it as well.                   FHWSV20                       10808                 20,0
FHW2RV valves are used for FHW fixed fan heaters, as well       FHWSV25                       10809                 25,0

HDGL, Door status sensor
                 HDGL is an adjustable-length roller            length of the lever can be adjusted.
                 lever with two positions. One circuit is
                 shorted if the lever is in neutral position;   Max. load              230 VAC, 4 A
                 the other circuit gets shorted if the lever    Protection level       IP67
                 is turned 41° in any direction. HDGL can       Dimensions (mm)        30 x 85 x 50 (casing)
                 be used in conjunction with REU and                                   110 x 17 x 90, ш50 (lever)
                 HDR42. A signal is sent to the 13 - 14
                 contacts, if the lever is in position 1. If
                 the lever is in the 30 to 41° position, no
                 signal is forthcoming. Its casing is made      Model              Product identification number    Price
                                                                HDGL                          10016                 35,0
                 from black- or gray-colored plastic. The

118
                                                                                          AXT - mounting sections
                          AXT401 and AXT402 - special             lowers their effectiveness. We recommend using these
                          mounting sections to bring the air      mounting sections to avoid this complication.
                          discharge plane closer to the gate-
                          way plane, used for curtains in the
                          HF and HD series.                       Model             Product identification number Price
In case the curtains are installed above automatic gates,         AXT401                        3072              423,0
which open upwards and into the premises, they will have          AXT402                        3073              551,0
to be mounted far away from the gate, which significantly

                                                                                            ASCB, Ceiling brackets
                     ASCB - Instead of AS curtains wall           set). The set consists of two mounting brackets.
                     mounting brackets, ASCB ceiling
                     mounting brackets can be used to
                     install the air curtain. The upper side of
                     each bracket has two holes to attach         Model              Product identification number     Price
                     the suspensions (not included in the         ASCB                           6972                  39,0


                                                                          HDS, Bracket for vertical mounting
                   HDS - designed for vertical mounting of        tain, thus changing the direction of the air discharge plane.
                   air curtains from the HD and HDWV series.      A single HDS bracket is needed to mount an HD curtain.
                   The set is comprised of two lamellas,          Dimensions (mm)              410 x 380 x 50
                   inserted one inside the other and fixed        Weight (kg)                  6.1
                   with bolts. The lower part of the bracket is
                   attached with bolts onto the floor and
                   upper part is attached to the end panel of
the air curtain. The HDS bracket allows to turn the air cur-      Model            Product identification number Price
                                                                  HDS                          3051              140,0


                                                                                            PBS, Wall mounting set
                     PBS - a wall mounting kit for all air        allowing the air curtain to be adjust-
                     curtain in PB, PBD, PG and PGD               ed.
                     series. Two black brackets are
                     attached to the top of the air curtain,
                     to be subsequently hung from a T-
                     shaped wall mounted bracket. There
                     are slides on the T-shaped bracket,          Model            Product identification number      Price
                                                                  PBS                         10695                   44,0


                                                                                          PBH, Pendulum hanging
                    PBH - a pendulum hanging designed             caps for the guides. Cables can be laid along
                    for all air curtains in the Portier Basic     the guides.
                    and Portier Basic Design series. The
                    guides are inserted into one other and
                    fixed with screws. The length is adjust-
                    ed after the screws are unscrewed.
                    They can be shortened by cutting off
the unnecessary length. The set includes several plastic
                                                                   Model              Product identification number     Price
                                                                   PBH                           10697                  97,0

                                                                              PBT, set of connecting parts set
                 PBT - set of connecting parts, facilitating
                 the connection of several Portier Basic
                 or Portier Basic Design air curtains in a
                 row, thus creating a single air curtain of
                 any desirable length. A plastic lamella
                                                                  Model             Product identification number     Price
and a metal bracket are included in the PBT set.                  PBT                          10696                  29,0


                                                                                                                               119
Accessories for air curtains




PGT, Set of connecting parts for PG
             PGT - Set of connecting parts for installation    Model            Product identification number Price
             of Portier Grand and Portier Grand Design air     PGT                         10612              293,0
             curtains.




PGMBV - Mounting panel for PG
                   PGMBV - Mounting panel for vertical         Model            Product identification number Price
                   installation of Portier Grand or Portier    PGMBV                       10611              284,0
                   Grand Design air curtains.




PGPG and PGLPG - Protective grilles
PGPG and PGLPG - Additional protective grilles for Portier    Model            Product identification number Price
Grand and Portier Grand Design air curtains, 1,020 mm         PGPG                        11611               96,0
and 1,560 mm long.                                            PGLPG                       11612              108,0



PBF, PGF - Portier removable panel
                       PBF and PGF - Removable front          PGFS - stainless steel panel for PG.
                       panels for Portier Basic, Portier      PGLFS - stainless steel panel for PGL.
                       Grand, Portier Basic Design and
                       Portier Grand Design air curtains.
                       Sold individually.
                       PBFB - black panel for PB curtains.    Model            Product identification number Price
You may apply any picture or decorative film as you           PBFB                          4200              52,0
decide.                                                       PBLFB                        4201               70,0
                                                              PBFS                         10693             156,0
                                                              PBLFS                       10694              208,0
PBLFB - black panel for PBL curtains.                         PGFS                        104319             170,0
PBFS - stainless steel panel for PB.                          PGLFS                       104320             229,0
PBLFS - stainless steel panel for PBL.




120
121
                                                                                                                           Systemair • 2008




    Representative Office of Systemair (Russia and CIS)              Representative Office of Systemair (Ukraine)
101000, Moscow, Archangelsky Lane, Bldg. 7, Block 1, Office 2   04116, Kiev, Marshal Rybalko St., Bldg. 10/8, Office 301
 Phone: +7 495 933 1437, 933 1436, • Fax: +7 495 933 1431       Phone: +38(044)223 3434       • Fax: +38(044)223 3311
   info@systemair.ua            www.systemair.ua                info@systemair.ua           www.systemair.ua

				