					   HARDWARE

   DEVICE DRIVERS


7/2/2011      HYPACK® 2011 Training Seminar   1
            How Many ??
 Currently HYPACK has between 400 - 500
  Device Drivers

 Approximately 200 are used with regularity

 Constantly modifying and maintaining them

 Always trying to make them better…
7/2/2011        HYPACK® 2011 Training Seminar   2
                      ADCP.DLL




• Collection for ADCPs (SONTEK and RD INSTRUMENTS) is now done with
  the ADCP.DLL.
• There is no longer a separate ADCP LOGGER program.

7/2/2011                HYPACK® 2011 Training Seminar                 3
           AIS.DLL and ARPA.DLL
           Automatic Identification System Transponders




• Generates mobile targets in SURVEY to denote vessel positions
7/2/2011                  HYPACK® 2011 Training Seminar           4
                                CUTTER.DLL
• Enhanced display of cutter suction dredge in
  DREDGEPACK.




HYPACK® 2011 Training Seminar                7/2/2011   5
                CUTTER.DLL
                  Configuration




                                                                     Cutter.shp




                                                     Arm_front.shp




Arm_prof.shp

                  Body_front.shp     Body_prof.shp
     7/2/2011    HYPACK® 2011 Training Seminar                                    6
                    DRAFTTABLE.DLL
                    Dynamic Draft Correction versus Speed




Now allows for Shallow Water and Deep Water curves.
  Interpolates when between the Shallow and Deep
                    Depth Limits.

 7/2/2011                 HYPACK® 2011 Training Seminar     7
           ECHOTOT.DLL
           Reads Several Echosounders




7/2/2011               HYPACK® 2011 Training Seminar   8
                  Excavator Drivers

Inclinometers




Directional GPS
• Position
• Heading




    7/2/2011          HYPACK® 2011 Training Seminar   9
           EXCAVATOR4.DLL
            Used for Excavator Systems




7/2/2011      HYPACK® 2011 Training Seminar   10
                GENDEVALL.DLL
           Reading Devices with Fixed Length Data Fields




7/2/2011                 HYPACK® 2011 Training Seminar     11
                   GENDEVPARSE.DLL
       Reading Devices with Comma, Space, or Tab separated Data Fields




                                                               Driver Test




 Raw Data from Device

                                 Driver Configuration

7/2/2011                   HYPACK® 2011 Training Seminar                     12
                      GENOFFSET.DLL
           Placing a ‘mobile’ at a fixed location on another ‘mobile’




Mobile ID = Mobile # of Main
Barge or Vessel (usually = 0)




7/2/2011                       HYPACK® 2011 Training Seminar            13
                    GPS.DLL
                  Main Setup Form

• Replaces the KINEMATIC.DLL
• See the HARDWARE – BASICS presentation for
  details….




  7/2/2011       HYPACK® 2011 Training Seminar   14
                     HYSWEEP.DLL
              Used to read data from HYSWEEP® SURVEY

• Allows HYPACK® SURVEY to access info from HYSWEEP®
  SURVEY and SIDE SCAN SURVEY via the Shared Memory Area.
      – Heave-Pitch-Roll Data
      – Depth at Nadir Beam
      – Gyro (if integrated in HYSWEEP SURVEY)

  SURVEY COMPUTER

                  Tide
                                  SHARED                   HYSWEEP®
                  Draft
                                  MEMORY                   SURVEY
                                  AREA
                                                           Heave-Pitch-Roll
                                                           Depth at Nadir
    HYPACK®
                                                           Gyro
    SURVEY

7/2/2011                   HYPACK® 2011 Training Seminar                      15
              INCLINOMETER.DLL
           Inclinometer for Cutter Suction Dredges and Cranes

                            • Used for A2TS (US Digital) and
                              Ocala Systems Inclinometers.




                               • Measures the vertical angle (from the horizon).




7/2/2011                    HYPACK® 2011 Training Seminar                   16
            LPT_TAP and LptEvt.DLLs
                Generating Event Marks via a Contact Closure

• Connection to PC:
      – Parallel: LPT_TAP.DLL (Older Boxes)
      – USB: LptEvt.DLL (Newer Boxes)




   LptEvt.DLL Setup:
          Generate contact closure at event marks.
          Generate contact closure when XTE is exceeded.

7/2/2011                      HYPACK® 2011 Training Seminar    17
                   MAGNET.DLL
                                   Geometrics 881          DF 1000 (Serial)
                                   Geometrics 882          Geometrics 881
                                   Marine Magnectis        Geometrics 882
                                    Seaspy                  Geometrics G-858
                                   Scintrex Envigrad       Insight Marine
                                   JW Fisher Proton 4       (881 Dual)
                                   DF 1000                 IXSEA Magis
                                   SMM II                  J W Fisher Proton 4
                                                             Marine Magnetics
                                                            Scintrex Envigrad
                                                            Seaquest
                                                            SMM II
                                                            UC Mag



                                                                   AVI


HYPACK® 2011 Training Seminar                 7/2/2011                   18
                            PLAYBACK.DLL
                           Replay RAW Data Files in SURVEY




                                                                         AVI

       •   ‘Connection’ should always be either a single RAW data file
           or a Catalog (*.LOG) of RAW data files.
HYPACK® 2011 Training Seminar                          7/2/2011                19
                 SEABEDID.DLL
    For Use with Roxann and EchoPlus Seabed ID Systems


•    Perform ‘Ground Truthing’ and create Seabed ID
     Square (*.SIX) in SEABED STATISTICS program.

•    In real time, E1 and E2 info is plotted on Seabed ID
     Square and in Profile view.

•    Data can be re-mapped to new *.SIX in Post-Processing




      7/2/2011                       HYPACK® 2011 Training Seminar   20
               SIM32.DLL and SIM33.DLL
• Positioning
          • Speed Up/Down
          • Turn Left/Right
• Echosounder
          • Single or Multiple Transducer
          • Generates Depths based on Sine Curve
• SIM33 Differences:
          • Speed and heading changes are
            continuously applied until ‘Steady’ or
            ‘Stop’ buttons are hit.




    7/2/2011                          HYPACK® 2011 Training Seminar   22
                     SONTEK M5




• This driver reads the acoustic single-beam echosounder data.
• It can also use the bottom-track information when you expect to have
  blockages from the GPS signal.
7/2/2011                  HYPACK® 2011 Training Seminar                  23
                       TIDEFILE2.DLL
                Read Predicted Tide Files (*.TID) Into SURVEY

   Tidefile2.DLL:
        Replaces TIDEFILE.DLL
        Nicer display
        User can adjust ‘on-the-fly’



   Both:
        Read *.TID file created in:
               MANUAL TIDES
               HARMONIC PREDICTION
        *.TID file is specified in
         Setup Window
        ‘Connect’ is set to ‘None’


     7/2/2011                           HYPACK® 2011 Training Seminar   24
              WebIF.DLL
• Used to view the SURVEY program
  (Area Map and Data) from an Intranet
  connection.

• Add WebIF.DLL to your HARDWARE
  configuration. It does not require any
  connection information.

• On another computer on the Intranet, you
  can then view the SURVEY or DREDGEPACK
  programs by entering the Web IP address
  (or computer name) with port 8080 (now
  configurable).
    – http://Pats-Fujitsu:8080
    – http://265.1.13.254:8080
    – http://localhost:8080 (to view on same computer)

  7/2/2011                        HYPACK® 2011 Training Seminar   25
                        YSI6600.DLL
                           Environmental Sensor
           •    YSI6600 (Sonde) can be configured with different sensor
                                    packages.

           •    Setup: Provide a name for each sensor, based on its channel.

           •    SURVEY: Driver displays text values and can display a graph for
                           all sensors.




7/2/2011       HYPACK® 2011 Training Seminar                               26

				