Docstoc

ACM Management Plan

Document Sample
ACM Management Plan Powered By Docstoc
					ASBESTOS MANAGEMENT PLAN
                       AND
  ASBESTOS OPERATING PLAN
 ONIZUKA AIR FORCE STATION
     SUNNYVALE, CALIFORNIA




                           Prepared By:

                          21 SOPS/CEV
               Onizuka Air Force Station
                   1080 Innovation Way
                   Sunnyvale, California


              Implemented: October 1992
                   Revised: January 2006
                                                               Asbestos Management Plan


TABLE OF CONTENTS

GEN ERAL INFORMATION AND CONTACTS (UPDATED S EPTEMB ER 2005)                        III

SECURITY AND ADMINIS TRATIVE INSTRUCTIONS                                            V

PLAN UPDATES & REVIS IONS                                                           VI

PLAN REVIEW                                                                         VI

ACRONYMS AND ABBREVIATIONS                                                         VII

DEFINITIONS                                                                       VIII

1     INTRODUCTION                                                                    1
    1.1     PLAN PURPOSE AND SCOPE                                                    1
       1.1.1     Plan Pu rpose                                                        1
       1.1.2     Plan Objectives                                                      1
       1.1.3     Confidentiality                                                      1
       1.1.4     Plan Scope and Applicability                                         1
    1.2     INST ALLATION DESCRIPTION                                                 2
       1.2.1     Onizuka Air Force Station                                            2
       1.2.2     Onizuka Annex                                                        2
    1.3     REGULATORY AND A IR FORCE POLICY OVERVIEW                                 3
       1.3.1     Federal Regulat ions                                                 3
       1.3.2     California Regulat ions                                              3
       1.3.3     Air Force Instructions                                               4
       1.3.4     Onizuka Air Force Station                                            4
    1.4     RESPONSIBILITIES                                                          4
       1.4.1     Installation Co mmander (21 SOPS/CC)                                 4
       1.4.2     Base Civil Engineer (21 SOPS/CE)                                     4
       1.4.3     Environmental Health & Safety (21 SOPS/CEV)                          4
       1.4.4     Bioenvironmental Engineering (60 AMDS/SGPB)                          5
       1.4.5     Staff Judge Advocate (50 SW/JA)                                      5
       1.4.6     Ground Safety Officer (21 SOPS/SE)                                   5
       1.4.7     Public A ffairs (21 SOPS/PA)                                         5
       1.4.8     Contracting Officer                                                  5
    1.5     U SE OF A SBESTOS                                                         5
    1.6     HEALT H EFFECT S OF A SBEST OS EXPOSURE                                   6
    1.7     A SBEST OS IDENTIFICATION                                                 6
2     GEN ERAL ASB ESTOS POLICIES AND PROCEDURES                                      7
    2.1     A IR FORCE A SBEST OS POLICY                                              7
    2.2     OAFS A SBE ST OS M ANAGEMENT A CT IVITIES                                 7
    2.3     A SBEST OS RECORD KEEPING REQUIREMENT S                                   7
    2.4     A SBEST OS FILE                                                           7
    2.5     A SBEST OS SURVEYS                                                        8
       2.5.1     Asbestos Rating System and ACM Surveys                               9
    2.6     PLANNING AND SCHEDULING ACM A BATEMENT                                    9
       2.6.1     In-house Work Requests                                               9
       2.6.2     Renovation Projects                                                  9



Onizuka Air Force Station                            i                         Pre face
                                                                  Revised January 2006
                                                                          Asbestos Management Plan


       2.6.3     Priorit izing Abatement Projects and Surveys                                    9
       2.6.4     Categorizing Survey Find ings                                                  10
       2.6.5     Asbestos Control Options                                                       10
    2.7     REGULATORY NOTIFICATION                                                             10
    2.8     A SBEST OS A WARENESS INFORMAT ION                                                  10
    2.9     TRAINING                                                                            10
    2.10 CONT RACT M ONITORING                                                                  11
    2.11 BUDGET ING                                                                             11
3     1993 ONIZUKA FACILITY ASB ES TOS S URVEY S UMMARY                                         12
    3.1    BUILDING 1001                                                                        12
    3.2    BUILDING 1002                                                                        13
    3.3    BUILDING 1003                                                                        14
    3.4    BUILDING 1004                                                                        14
    3.5    BUILDING 1005                                                                        15
    3.6    BUILDING 1006                                                                        15
    3.7    BUILDING 1010                                                                        16
    3.8    BUILDING 1013                                                                        16
    3.9    BUILDINGS 1018, 1020, 1026 AND 1003-2                                                16

LIST OF TAB LES
Table 1: General In formation and Contacts                                                      iii
Table 2: Plan Updates                                                                            vi
Table 3: Plan Rev iew Log                                                                        vi
Table 4: Asbestos Survey Results                                                                 8
Table 5: Bu ild ings Not Surveyed Based on Age and Type of Construction                          8
Table 6: Bu ild ing 1001 Assessment Areas                                                       12
Table 7: Su mmary of Building 1001 Asbestos Removal Projects                                    13
Table 8: Bu ild ing 1002 Assessment Areas                                                       13
Table 9: Su mmary of Building 1002 Asbestos Removal Projects                                    14
Table 10: Building 1003 Assessment Areas                                                        14
Table 11: Su mmary of Building 1003 Asbestos Removal Projects                                   14
Table 12: Building 1004 Assessment Areas                                                        15
Table 13: Building 1005 Assessment Areas                                                        15
Table 14: Su mmary of Building 1005 Asbestos Removal Projects                                   15
Table 15: Building 1006 Assessment Areas                                                        16
Table 16: Building 1010 Assessment Areas                                                        16
Table 17: Building 1013 Assessment Areas                                                        16




Onizuka Air Force Station                                 ii                              Pre face
                                                                             Revised January 2006
                                                                                 Asbestos Management Plan


GEN ERAL INFORMATION AND CONTACTS (UPDATED S EPTEMB ER 2005)

Name of Installation                          Onizuka Air Force Station
Location of Installation                      Santa Clara County, Sunnyvale,
                                              Californi a
Type of Installati on                         AFSPC: Satellite Control
Primary Hazardous Waste Management
Organization:                                 Ci vil Engineering (21 SOPS/CE)


POINTS OF CONTACT (POC):
Environmental Coordi nator (21 SOPS/CEV)                                            408-752-4184
Environmental Manager(21 SOPS/CEV-1)                                                408-752-3721
Asbestos Management Plan                                                            408-752-3721
Asbestos Program Manager                                                            408-752-3721
Hazardous Materials HazMart Technician                                              408-752-3910
Environmental Engineer                                                              408-752-6215
Fire Chief (21 SOPS/CEF)                                                            408-752-4292
Disaster Preparedness                                                               408-752-4443
Ground Safety Officer (21 SOPS/SE)                                                  408-752-3470
Bioenvironmental Engineering (30 MDG/S GGB                                          805-606-7811
Vandenberg AFB )                                                                    (DSN) 276-7811
Ci vil Engineering Service Desk                                                     408-752-3992
Command Post                                                                        408-752-3840
Public Affairs (21 SOPS/PA)                                                         408-752-4026
Staff Judge Advocate (50 SW/JA)                                                     719-567-5050
                                                                                    (DSN 560-5050)
Security Police (21 SOPS/SF)                                                        408-752-3924
Contracting Officer                                                                 408-752-3057

OTHER CONTACTS:
Emergency Medical Care                        El Camino Hos pital                   650-940-7055
                                              Sunnyvale Dept. of Public Safety      99-911(external)
                                                                                    or 117 (internal)
EPA Region IX As bestos Coordinators
Patricia Maravilla                            TSCA Coordinator                      415-744-1122
Bob Trotter                                   NES HAP Coordi nator                  415-744-1145
National Response Center                                                            1-800-424-8802
State Emergency Response Agency               Californi a Office of Emergency       1-800-852-7550
                                              Services
Local Emergency Response Agency               Sunnyvale Dept. of Public Safety      99-911 (external)
                                                                                    or 117 (internal)
Table 1: General Information and Contacts




Onizuka Air Force Station                    iii                                                 Pre face
                                                                                    Revised January 2006
                                                                                                Asbestos Management Plan


INSTALLATION IMPLEM ENTING INSTRUCTION

Date:                14 December 2004

OPR:                 21 SOPS/CEV

Subject:             Onizuka Air Force Station, Asbestos Management Plan

References:          Air Force Instructions 32-1052, Code of Federal Regulat ions Title 40 Part 763

Purpose:             To imp lement a co mprehensive plan to manage items containing asbestos at Onizu ka Air Fo rce
                     Station (OAFS), the Moffett Federal Airfield Golf Course (Go lf Course), and ensure installation
                     compliance with applicable federal, state and Air Force asbestos regulations.

Applicability:       The Asbestos Management Plan requirements apply to all installation personnel and contractors
                     working at OAFS and the Golf Course.

Action:              The original OAFS Asbestos Management Plan became effective October 1992. This revision
                     supercedes all previous revisions of the OAFS Asbestos Management Plan.

Distribution:        21 SOPS/CC        50 SW/CES         21 SOPS/PA        21 SOPS/DO
                     21 SOPS/MA        21 SOPS/LG        21 SOPS/CE




                     Signature: _______________________________________                      Date: ______________
                                 Co mmander, 21st Space Operat ions Squadron




Onizuka Air Force Station                                  iv                                                      Pre face
                                                                                                      Revised January 2006
                                                                                                 Asbestos Management Plan


SECURITY AND ADMINIS TRATIVE INSTRUCTIONS

Title:                 The title of this document is the Onizuka Air Force Station, Asbestos Management Plan. The
                       plan will be referenced throughout this document as the OAFS Asbestos Plan.

Classification:        This document is unclassified. It does not fall within the scope of directives governing the
                       protection of informat ion affecting National Security as specified in the AFI 31 series.

Responsibilities:      21 SOPS/CEV is the office of primary responsibility (OPR). Squadron commanders are
                       responsible for ensuring that their personnel are aware of the OAFS Asbestos Plan and comply
                       with its requirements.

Review/Changes:        Review of the OAFS Asbestos Plan and any resulting amendments or changes must be logged
                       on Table 2 and Table 3.

                       When amendments or changes significantly revise policies, procedures or data presented in the
                       Asbestos Plan, the Plan must be re-approved by the Environmental Protection Co mmittee
                       (EPC).

                       The OAFS Asbestos Plan is subject to revision if any applicable laws, regulat ions, or
                       requirements are changed.

                       Co mponents of the OAFS Asbestos Plan will be rev iewed and updated annually to ensure that
                       informat ion contained herein is current. 21 SOPS/CEV will document reviews on the Plan
                       Update Log (Tab le 2).




Onizuka Air Force Station                                   v                                                     Pre face
                                                                                                     Revised January 2006
                                                                                           Asbestos Management Plan


PLAN UPDATES & REVISIONS

Revisions reflect significant changes to the plan. Revisions can include format changes or changes due to
significant revisions of policies, operations and/or regulations. A revised plan must be submitted for review by
organizations responsible for Asbestos management and signed by the Installation Co mmander. An update reflects
minor changes that are not a result of operational and/or regulatory changes or significant changes to the plan's
format. For examp le, updates include a Point-of-Contact (POC) name change, or addition of annual metrics data.
An update does not require rev iew by organizations other than 21 SOPS/ CEV or resubmission for signature by the
Installation Co mmander.

Reviewed B y        Organization     Date Reviewed     Remarks
N/A                 750 M SS/ CEV    October 1992      Implemented
                    750 M SS/ CESE   May 1997          Revised and Updated
                    21 SOPS/CEV      May 2002          Reviewed and Updated
                    21 SOPS/CEV      Dec 2004          Reviewed and Updated
                    21 SOPS/CEV      Sept 2005         Reviewed and Updated
                    21 SOPS/CEV      Jan 2006          Reviewed and Updated



Table 2: Plan Updates



PLAN REVIEW

The Revised OAFS Asbestos Plan is submitted, under a Staff Su mmary Sheet, to organizat ions with Asbestos
management responsibilities for review and co mment. Organizat ions are to forward suggested changes and
comments to 21 SOPS/ CEV, the Office of Primary Responsibility (OPR). The table below summari zes co mments
received by 21 SOPS/CEV for the current revision of the plan.

Reviewed B y        Organization     Date Reviewed     Remarks
                    21 SOPS/CEV      May 2002          ACM survey programmed for FY 03. Approved.
                    21 SOPS/CEV      Dec 2004          ACM survey pending; additional funding required
                    21 SOPS/CEV      Sept 2005         Updated training requirements in sec. 2.9
                    21 SOPS/CEV      Jan 2006          Updated contact information.




Table 3: Plan Review Log




Onizuka Air Force Station                              vi                                                   Pre face
                                                                                               Revised January 2006
                                                                              Asbestos Management Plan


ACRONYMS AND ABBREVIATIONS

The following acronyms and abbreviations are used throughout this document:

ACM – Asbestos Containing Material

AFI - Air Force Instructions.

Cal-OSHA - Californ ia Occupational Safety and Health Ad ministration.

CCR - Califo rnia Code of Regulations.

CFR - Code of Federal Regulat ions.

DOD - Depart ment of Defense.

DTSC - California Depart ment of To xic Substances Control.

EPA- Env iron mental Protection Agency.

HSC - California Health and Safety Code.

OAFS - Onizuka Air Force Station

OSHA - Occupational Safety and Health Admin istration.

PPE - Personal Protective Equip ment.




Onizuka Air Force Station                             vii                                     Pre face
                                                                                 Revised January 2006
                                                                                                  Asbestos Management Plan


DEFINITIONS

ACM (Asbestos-containing material) - a material containing more than 1% asbestos as determined using EPA-
approved polarized light microscopy methods.

Asbestos - includes the minerals chrysolite, amosite, crocidolite, tremolite, anthophyllite, actinolite, and any of these
minerals that have been chemically t reated and/or altered.

Bulk sample - a solid quantity of insulation, floor t ile, building material, etc., suspected of containing asbestos fiber
and that would be analyzed for the presence, quantity, and type of asbestos.

Exposure assessment - an assessment conducted to determine if the potential exists for regulated exposure limits to
be exceeded during an asbestos project.

Friable ACM - Dry ACM that may be cru mb led, pulverized, or reduced to powder by hand pressure.

Nonfriable ACM - dry ACM that cannot be crumbled, pu lverized, o r reduced to powder by hand pressure.
Nonfriable asbestos is further divided into Categories I (packings, gaskets, resilient floor covering, and asphalt
roofing) and Category II (any non-friable material not in Category I).

PEL (permissible exposure limit):

    1. Time weighted average (TWA) - The employer shall ensure that no employee is exposed to an airborne
concentration of asbestos in excess of 0.1 fiber per cubic centimeter (0.1 f/cc) o f air as an eight (8) -hour time -
weighted average (TWA) as determined by the method prescribed in Appendix A to this section, or by an equivalent
method.

    2. Excursion limit: The emp loyer shall ensure that no employee is exposed to an airborne concentration of
asbestos in excess of 1.0 fiber per cubic centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30)
minutes as determined by the method prescribed in Appendix A to this section, or by an equivalent method.


RACM (Regulated ACM) - 1) Friab le ACM; 2) Category I Nonfriab le ACM that has become friab le due to
destructive handling; 3) Category I Nonfriable A CM that will be or has been subjected to sanding, grinding, cutting,
or abrading; or 4) Category II Nonfriable ACM that has a high probability of beco ming or has become cru mb led,
pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or
renovation.

Regulated area - a demarcated area established by the employer where Class I, II, and III asbestos work is
conducted; any adjoining area where debris and waste fro m such asbestos work accu mu late; and a work area where
airborne concentrations of asbestos exceed, or there is a reasonable possibility they may exceed, the PELs.




Onizuka Air Force Station                                  viii                                                    Pre face
                                                                                                      Revised January 2006
                                                                                                 Asbestos Management Plan


1 INTRODUCTION

1.1       Plan Purpose and Scope

1.1.1      Plan Purpose

The OAFS Asbestos Plan outlines organizational responsibilities and procedures that have been develope d to protect
facilit ies occupants from exposure to airborne asbestos fibers. The OAFS Asbestos Plan has been prepared in
accordance with Air Force Instruction (AFI) 32-1052, "Facility Asbestos Management," March 1994, which
requires the development of adequate procedures to manage existing asbestos -containing material (A CM) and CCR
Title 8 Section 5208. The OAFS Asbestos Plan serves as the Onizu ka Air Fo rce Station Asbestos Management Plan
and Asbestos Operating Plan as required by AFI 32-1052. The Environ mental Protection Co mmittee (EPC) has the
responsibility fo r implementing the OAFS Asbestos Plan.

1.1.2      Plan Objecti ves

The objective of asbestos management planning is to ensure compliance with federal, state and Air Force
environmental and safety regulations and instructions regarding the handling and management of ACMs. The focus
of the plan is to:

          Define requirements for the effective management of asbestos at OAFS and annexes, includ ing specific
           tasks for meet ing regulatory requirements and for protecting the health of facility personnel.

          Establish a system of identification, evaluation, and prioritization of suspected asbestos related hazards so
           mitigation resources can be appropriated in a logical, cost effective manner.

          Demonstrate compliance with regulatory and Air Force policy requirements concerning ACM by ensuring
           that organizational responsibilit ies are clearly and specifically defined.

          Establish a comp lete, usable, facility-specific database for recording information on ACM, and ensure that
           the database is kept current.

1.1.3      Confi dentiality

The OAFS Asbestos Plan does not provide the general public with potentially sensitive information regard ing
missions or the facility. However, the public may request informat ion in accordance with the Freedom of
Information Act (FOIA). Responses will be provided in accordance with A ir Force policy and FOIA requirements,
to ensure proprietary and/or national security information remains confidential.

1.1.4      Plan Scope and Applicability

The OAFS Asbestos Plan limits its scope to the management of ACMs, and applies to OAFS and the Moffett Golf
Course. All military, civ il service and contractor personnel working at any of these facilities must adhere to the
provisions of the OAFS Asbestos Plan. Responsibilities have been delegated to individuals and/or organizations as
identified throughout the various sections of the OAFS Asbestos Plan.

Although this Plan is limited to asbestos management issues, additional environmental protection plans (i.e.,
Hazardous Waste Management Plan (HWMP), and Po llution Prevention, etc.) have been developed to address
related environ mental co mpliance, and management and contingency procedures. These plans have been referenced
as appropriate to ensure consistency between plans.



Onizuka Air Force Station                                   1                                        Asbestos Management
                                                                                                     Revised January 2006
                                                                                                Asbestos Management Plan



1.2     Installation Description

1.2.1     Onizuka Air Force Station

OAFS occupies approximately 23 acres in the City of Sunnyvale, Santa Clara County, Californ ia, and is located
forty miles southeast of San Francisco at the southern edge of San Francisco Bay. Highway 237 borders OAFS to
the south, with residential and co mmercial develop ments to the east and south. Recently built office co mp lexes are
located to the west and north (e.g., Ariba, located west of the South Parking Area, and Juniper Networks located
across fro m the North Parking Area) of OAFS. The Lockheed Martin M issile and Space Co mpany is west of Gate
One. Moffett is situated approximately two miles northwest of OAFS, where residential housing is available for
military personnel stationed at OAFS.

Originally established in 1960, as the Satellite Test Center for the 6594th Test Wing, it was re-designated Sunnyvale
Air Force Station in 1970. In 1986, its name was changed to Onizuka A ir Force Station in honor of Space Shuttle
Challenger astronaut Colonel Ellison S. Onizuka. In 1987, as part of an Air Force -wide organizational change, the
installation was renamed Onizuka A ir Force Base, and in 1994, the name was changed to Onizuka Air Station. Most
recently, in March 2000, the name was changed to Onizu ka Air Force Statio n.

On October 1, 1987, Air Force Space Co mmand (AFSPC) became the major co mmand host. On January 30, 1992,
the 750th Space Group (750 SG) was activated at OAFS as a subordinate unit of the 50th Space W ing (50 SW),
Schriever A ir Force Base in Co lorado. Upon the deactivation of 750 SG in June 1999, the 21st Space Operations
Squadron (21 SOPS) became the host unit. There are appro ximately 1,900 contractor/civilian personnel and 100
military personnel at OAFS.

OAFS t racks, tests, operates, and controls a variety of mult i-functional defense satellites, supports non-military
space vehicle activit ies, evaluates procedures and prototype equipment for the entire satellite and control network,
and disseminates informat ion.

Since its inception, industrial activ ity at OAFS has been limited main ly to the preservation and upkeep of the power
plant and distribution systems, facility maintenance, engineering, security, reprographics, communicat ions and
satellite control systems, hazardous materials storage and distribution, temporary hazardous waste storage, custodial
services and solid waste management.

1.2.2     Onizuka Annex

Moffett Federal Airfield Golf Course
The Moffett Golf Course occupies approximately 190 acres of low-ly ing land in the northeastern portion of Moffett
Federal A irfield. Since the 1930’s, the Un ited States Navy used the Moffett Golf Course area for various purposes,
including a landfill site. There are three known, non-active, Navy landfills areas located toward the north and
northeastern sides of the Moffett Golf Course. The Air Force has never used or operated any of the non -active
landfills, and in accordance with the 1994 Federal Facilit ies Agreement between Un ited States Environ mental
Protection Agency (USEPA) and the Un ited States Navy, the Navy retains responsibility for the landfills.

Develop ment of the Moffett Golf Course started in the late 1950s. The Moffett Go lf Course expansion west of
Marriage Road Ditch occurred around 1966. Prior to the transfer of the Moffett Golf Course fro m t he Navy to
NASA-A mes, and leasing of the property to the Air Force, Navy Morale Welfare and Recreation (MWR)
maintained the Moffett Golf Course. The Air Force currently leases the Moffett Golf Course fro m NASA -A mes,
and has operated the facility since March 1994. The lease agreement requires the Air Force to provide maintenance
services and environmental and safety oversight. The Go lf Course build ings are included in the NASA -A mes
asbestos management program.




Onizuka Air Force Station                                 2                                        Asbestos Management
                                                                                                   Revised January 2006
                                                                                                  Asbestos Management Plan

NEX Facilities
The Naval Exchange operates the NEX Gas Station and a retail store at Moffett Field, in accordance with the
requirements of the support agreement between the Air Force and Naval Exchange. Ho wever, NASA -A mes
provides asbestos management to the NEX facilities, therefore NEX is not with in the scope of this plan.

1.3       Regulatory and Air Force Policy Overvie w

In accordance with Air Force policy, OAFS Facilit ies comp ly with federal, state and local regulat ions and Air
Force/DoD instructions/directives. This section only lists those regulations most applicable to the management of
asbestos. Other federal and state regulations not listed below regulate storage, handling, and disposal of hazardous
waste materials. Refer to the OAFS Hazardous Waste Management Plan and OAFS Pollution Prevention Plan for
applicable hazardous waste regulations.

1.3.1      Federal Regulations

OSHA has established several standards to protect workers fro m exposure to asbestos.

          29 CFR 1910.1200, Occupational Safety and Health Standards, Hazard Co mmunicat ion.
          29 CFR 1910.1001, Occupational Safety and Health Standards, Asbestos.
          29 CFR 1926.1101, Safety and Health Regulat ions for Construction, Asbestos.
          40 CFR 61, Subpart M, Nat ional Emission Standards for Hazardous Air Pollutants (NESHAP).
          40 CFR 260-265, Hazardous Waste Management Regulat ions.
          40 CFR 302, Designation, Reportable Quantities Notification.
          40 CFR 373, Reporting Hazardous Substance Activities When Selling or Transferring Federal Real
           Property.
          40 CFR 141, National Primary Drin king Water Standards.

Construction work, as defined in 29 CFR 1910.12(b), is the primary activ ities at OAFS that may present asbestos
exposure issues to facility personnel. These activities include:

          Demolition or salvage of structures where asbestos is present.
          Removal o r encapsulation of materials containing asbestos.
          Construction, alteration, repair, maintenance, or renovation of structures, substrates, or portions thereof,
           containing asbestos.
          Installation of products containing asbestos.

If asbestos is present, construction activities will require co mp liance with 40 CFR 61, wh ich regulates the following:

          Fugitive emission fro m wo rk sites.
          Removal requirements before demolition.
          Notification requirements before disturbance of ACMs.

1.3.2      Californi a Regulati ons

          Bay Area Air Quality Management District (BAAQM D) Regulat ion 11, Ru le 2, Asbestos Demolition,
           Renovation and Manufacturing.
          8 CCR §1529: Subchapter 4. Construction Safety Orders, Article 4. Dust, Fu mes Mists and Gases.
          8 CCR §5208: Subchapter 7. General Industry Safety Orders, Article 110. Regulated Carcinogens.




Onizuka Air Force Station                                    3                                        Asbestos Management
                                                                                                      Revised January 2006
                                                                                               Asbestos Management Plan

1.3.3      Air Force Instructi ons

          AFI 32-1052, Facility Asbestos Management.
          AFI 32-7080, Po llut ion Prevention Program.

1.3.4      Onizuka Air Force Station

          Hazardous Waste Management Plan, Onizu ka Air Fo rce Station.

1.4       Responsibilities

1.4.1      Installati on Commander (21 SOPS/CC)

          Sets overall installation asbestos management policy.
          Reviews and approves the OAFS Asbestos Plan and any changes made during annual rev iews and updates.

1.4.2      Base Ci vil Engineer (21 SOPS/CE)

          Office o f Primary Responsibility (OPR) for asbestos management.
          Approves all Civ il Engineering manpower and financial resources necessary to execute the asbestos
           management program.

1.4.3      Environmental (21 SOPS/CEV)

          Reviews and Updates the OAFS Asbestos Plan.
          Maintains records of ACM identified during facility surveys or other projects.
          Implements the Installation asbestos management program as directed by the EPC.
          Provides asbestos management guidance to installation organizations.
          Coordinates with federal, state, local regulatory agencies and Air Fo rce organizations regarding asbestos
           management (e.g., reports to regulatory agencies, Wing, etc.)
          Coordinates sampling and analysis of potential asbestos containing materials and waste streams.
          Ensures proper storage, labeling, documentation, transportation and disposal of asbestos containing waste.
          Approves and signs Uniform Hazardous Waste Manifests and any other documentation required for
           asbestos disposal.
          Ensures that health related criteria are considered in the prio rit ization and scheduling of a sbestos
           abatement.
          Coordinates all asbestos abatement actions with organizations responsible for other aspects of the program.
          Reviews all self-help work for the presence of ACM. No self-help work involving ACM will be allowed.
          Ensure that in-house work orders, job orders, pro jects and work to be accomp lished are checked to
           determine if asbestos is present, exposed, or suspected.
          Coordinates training for base personnel involved in ACM management activit ies. Training including
           asbestos identificat ion and handling procedures.
          Will notify 30MDG/ SGGB immediately when damaged asbestos is discovered.
          Will notify SE with in 24 hours of discovering an asbestos release.
          Will notify JA immediately if in the event of asbestos regulation violations and/or known or s uspected
           human exposures to asbestos.




Onizuka Air Force Station                                  4                                      Asbestos Management
                                                                                                  Revised January 2006
                                                                                                  Asbestos Management Plan

1.4.4      Bioenvironmental Engineering (30 MDG/SGGB)

          Coordinates with 21 SOPS/ CEV on asbestos sampling and analysis.
          Provides input as to whether repair, maintenance, or removal of A CM is necessary.
          Performs bulk asbestos sampling, build ing surveys, or air samp ling as required.
          Identifies the potential for hu man exposure to asbestos and determine whether extraord inary precautions,
           such as frequent monitoring, removal of personnel fro m the area, temporary controls, or other protective
           measures are necessary to protect personnel until reco mmended actions are comp leted.
          Assist SE in determin ing potential health hazards, when damaged asbestos is discovered or asbestos is
           released into the environmental.

1.4.5      Staff Judge Advocate (50 SW/JA)

          Reviews all activ ities involving asbestos to ensure regulatory compliance and provide legal oversight.
          Coordinates on proposed base actions for compliance with applicab le federal, state and Air Force
           requirements.
          Review permits applications and/or licenses required for the disposal of asbestos as required.
          Reviews inspections by federal, state, and local regulatory agencies, (and inspection results); notices of
           violation (NOV) issued by federal, state, and local agencies; and reports documenting known or suspected
           human exposures to asbestos.

1.4.6      Ground Safety Officer (21 SOPS/SE)

          Assists 21 SOPS/CEV with physical safety concerns associated with the asbestos management program.
          Stays abreast of asbestos abatement activities and safety precaution s, procedures, and policies related to the
           OAFS asbestos management program.

1.4.7      Public Affairs (21 SOPS/PA)

          Responsible for interfacing with the media and general public concerning asbestos -related incidents.

1.4.8      Contracting Officer

          Works closely with 21 SOPS/CE and 21 SOPS/CEV to ensure contractors adhere to contract specifications
           and avoid non-compliance with asbestos regulations and AFOSH standards.
          Responsible for notifying contractors of non-compliance and stopping work that could potentially
           compro mise the health and safety of facility personnel.

1.5       Use of Asbestos

Due to its chemical and physical properties, the majority of asbestos has been used in the construction industry,
primarily fo r thermal insulation, fireproofing, and acoustical insulation. It has also been woven into fabrics for use
in ductwork expansion joints and fireproof curtains. It has been used as a strengthening agent in concrete, floor tile,
mortar, grout, and drywall speckling compounds. In general, asbestos has been identified in over 3,000 materials
typically used in build ings.




Onizuka Air Force Station                                   5                                        Asbestos Management
                                                                                                     Revised January 2006
                                                                                               Asbestos Management Plan

1.6     Health Effects of Asbestos Exposure

Friable asbestos is the only asbestos that poses a health hazard. Friab le ACM is defined as ACM that can be
crumb led, pulverized, or reduced to powder by hand pressure (non-friab le asbestos is not crumbled, pulverized or
reduced to a power by hand pressure). However, damage to non -friable ACM caused by an external disturbance
(i.e., d rilling, ch iseling, etc.) can potentially release asbestos fibers to the air.

Individuals can be exposed to asbestos through dermal contact, ingestion, or inhalation. The greatest risk to health is
inhalation of asbestos particles, follo wed by ingestion, and then dermal contact. Several health disorders have been
identified as resulting fro m exposure to airborne asbestos fibers (e.g., lung cancer, asbestosis, etc.). The to xic
effects of asbestos stem fro m particle size and shape more than chemical co mposition. All asbestos -related diseases
have long latency periods of ten to forty years. Although not an immediate health risk, worker education is
necessary to minimize unwarranted exposure.

Although dermal exposure to asbestos is not believed to produce dangerous or irreversib le affect, protective clothing
is universally reco mmended and used when working with or around asbestos. The purpose of protective clothing is
to facilitate worker decontamination and prevent spread of fibers outside the work area, thereby exposing other
individuals.

1.7     Asbestos Identification

Asbestos identification is accomplished using microscopic techniques. The analytical method used is a function of
the type of sample submitted for analysis, either bulk or air.

Polarized Light Microscopy (PLM), an analytical method established by the National Bureau of Standards (NBS), is
used to analyze bulk samples. PLM involves using dispersion staining to distinguish between the different types of
asbestos present in a sample. Sensitivity of this method is one percent by weight, (1,000 PPM) and leads to the
definit ion of an asbestos containing material (A CM). Samples that contain greater than one-tenth of one percent
(0.1%) asbestos are considered to be ACM in Californ ia. Samples containing more than one percent (1%) asbestos
are considered ACM by federal standards.

Air samples are analy zed using either Phase Contrast Microscopy (PCM) or Transmission Electron Microscopy
(TEM). PCM has limited sensitivity, making asbestos fibers difficult to d istinguish from non -asbestos fibers.
National Institute of Safety and Health (NIOSH) method 7400 is used to analyze air samples by PCM. Any fiber
with a length to width ratio of 3:1 is considered to be an asbestos fiber when using PCM. TEM is used to
distinguish between asbestos and non-asbestos fibers. TEM can detect particles orders of magnitude smaller than
those seen using light microscopes.

Air samples are collected to monitor airborne asbestos fibers levels in a work area. Samples are co llected using
personal monitoring pu mps or larger volu me floor pumps. The samples are us ed to determine respiratory protection
requirements for wo rkers. Air samp ling is also conducted following a response action or abatement project to
determine if the wo rk area has been sufficiently cleaned. National Institute for Occupational Safety and Health
(NIOSH) method 7400 is used to analyze both personal and clearance air samples.




Onizuka Air Force Station                                 6                                       Asbestos Management
                                                                                                  Revised January 2006
                                                                                                 Asbestos Management Plan


2 GENERAL ASBESTOS POLICIES AND PROCEDURES

2.1        Air Force Asbestos Policy

ACM in A ir Force facilities does not pose an imminent hazard unless it is friable, or is subjected to a mechanism or
event capable of breaking up ACM into individual fibers that become airborne.

Air Force policy as applied to OAFS is to effect ively manage non -friable A CM in place until a facility is demolished
or renovated. All construction/demolit ion projects must be evaluated for ACM prior to beginning the project;
damaged ACM or ACM that could become damaged during the project must be abated prior to, or as part of, the
project.

The decision to remove damaged or friab le A CM fro m a facility is based on the potential exposure risk to the
occupants, use of the facility, feasibility of repairs, frequency of repair and cost. When health and safety issues
mandate the removal of ACM fro m a facility, asbestos abatement is given immediate priority.

2.2        OAFS Asbestos Management Activities

Asbestos management activ ities at OAFS include budgeting, scheduling and planning, contract monitoring,
maintenance of files, and train ing.

2.3        Asbestos Record Keeping Require ments

Asbestos records compile co mprehensive information about all A CM on Base. They will be updated each time a
survey, inspection, or surveillance is performed; a facility with ACM is worked on; or asbestos sampling is
conducted. 21 SOPS/ CEV maintains and updates the asbestos records. These records a re kept for a min imu m o f 30
years. Asbestos records are comprised of two co mponents:

           Asbestos Files
           Asbestos Surveys

2.4        Asbestos File

21 SOPS/CEV maintains a permanent file detailing asbestos activities, which includes the following:

      1.    ACM surveys completed.

      2.    Results of all samp ling and testing performed, including bulk sampling and air monitoring.

      3.    ACM abatement contract documents including:

               Cert ifications and licenses of contractor personnel conducting asbestos work.
               Statements of Work (SOWs).
               Results of all personnel and area air sampling.

      4.    Descriptions of all asbestos abatement activities performed, including dates, type of remediation, personnel
            involved, quantity of any asbestos that was removed, disposal method and location, and results of post -
            control activity inspection/ sampling.

      5.    Copies of notification letters sent to the EPA and the BAAQM D.




Onizuka Air Force Station                                   7                                       Asbestos Management
                                                                                                    Revised January 2006
                                                                                                  Asbestos Management Plan


      6.    Emp loyee train ing records.

      7.    Copies of disposal documents, including copies of Unifo rm Hazardous Waste Manifests.

      8.    Copies of federal, state, and Air Force regulations concerning asbestos.

      9.    Other relevant reports, studies, and informat ion deemed necessary by 21 SOPS/CEV.

2.5        Asbestos Surveys

Managing asbestos requires identifying locations containing ACM, assessing its condition, determin ing whether it
presents a health hazard, defin ing appropriate control activities, and ensuring that priority attention is given to areas
posing the greatest health hazard.

The most effective method for identify ing locations containing ACM and ascertaining their condition is t hrough a
comprehensive facilit ies survey. OAFS conducted a comprehensive base-wide asbestos surveys in 1987 and 1993.
Table 4 provides a listing of the buildings surveyed and a summary of the 1993 survey results. Table 5 lists t hose
buildings that were determined not to contain ACM, based upon the age and/or type of building construction, and
therefore were not included in the survey.

           Building             Contains                         Building                Contains ACM
                                  ACM
       Building                 Contains                         Building                Contains ACM
                                  ACM
         1001                      Yes                              1002                        Yes
         1003                      Yes                              1004                        Yes
         1005                      Yes                              1006                        No
         1009                      No                               1010                        No
         1012                      No                               1013                        No
         1015                      No                               1016                        No
         1018                      No                               1020                        No
         1021                      No                               1022                        No
Table 4: As bestos Survey Results

              Building #                             Descripti on                  Construction Date
                10035                              UPS Building                          1997
                10031                                Office Area                       Sep 1985
                10032                                Office Area                       Apr 1986
                1034                        Warehouse & Office A rea                   Sep 1990
                1008                          JP-5 Storage Structure
                1025                                   Armo ry                          Sep 1985
                1040                       Satellite Accu mulation Shed                 Mar 1988
                1042                            POL Storage Shed                        Mar 1988
                1043                                Guard Station                         1999
               Gate 2                               Guard Station                         1999
                EUB                        Emergency Utility Bu ild ing                   1996
Table 5: B uil dings Not Surveyed Based on Age and Type of Construction




Onizuka Air Force Station                                    8                                        Asbestos Management
                                                                                                      Revised January 2006
                                                                                               Asbestos Management Plan



2.5.1      Asbestos Rating System and ACM Surveys

Past ACM surveys did not use the Air Force Asbestos Guidance for Rat ing and Assessing Damage and Exposure
(GRADE) rating system. Ho wever, the 1993 ACM survey conducted at OAFS (excluding annex properties) by
Pacific Env iron mental Services, Inc. (PES) includes the GRADE rating system for assigning an Air Force Priority
(AFP) as follows:

          AFP 0: No Asbestos Identified.
          AFP 1: Immediate Removal. In terms of both damage and exposure potential, the situation warrants
                  immed iate removal in spite of the large potential fo r fiber release during abatement.
          AFP 2: Removal as Soon as Possible. Asbestos containing material should be removed as soon as
                  possible, not waiting for the normal repair and maintenance cycle. In a school, for instance,
                  removal should be accomplished during the summer or during recess periods. In a co mmercial
                  building, it can be accomp lished at night over a period of days. Prior to actual removal, it may be
                  wise to limit access to that part of the building.
          AFP 3: Planned Removal. The hazard involved in these areas is such that removal should take place as
                  part of the normal maintenance and repair cycle of a facility. Th is approach min imizes cost and
                  disturbance.
          AFP 4: Repair. The most damaged areas should be repaired by encapsulation or replacement.
          AFP 5: Monitoring. Periodic monitoring of these areas should be planned to control, minimize and repair
                  any future damage.
          AFP 6: No Immediate Action. Asbestos containing material is well protected and fiber release is very
                  unlikely. No current action should be undertaken.

2.6       Planning and Scheduling ACM Abatement

2.6.1    In-house Work Requests
All work requests (AF form 332) received by Civil Engineering will be rev iewed by 21 SOPS/ CEV to determine if
ACM is involved in the work request, if it cannot be determined, CES will have a survey performed to identify t he
presence of the ACM. If ACM is present and affects a work request, CEV will schedule asbestos abatement and
inform the work requester.

2.6.2   Renovati on Projects
For renovation projects 21 SOPS/ CEV will consult the asbestos register or init iate a survey to d etermine if ACM is
involved in a project. If A CM is found during the survey, abatement will be included in the renovation project
scope.

2.6.3      Prioritizing Abatement Projects and Surveys

21 SOPS/CEV will prioritize and schedule asbestos control activities and surveys based on project requirements and
the hazards identified. Asbestos abatement will be scheduled in the following order:

Immediate Response:
    AFP 1 items: Damaged asbestos presents an immed iate health hazard o r mission impact (RAC I & II).
    AFP 2 items: ACM is damaged and may present an immed iate exposure risk (RAC III, IV & V).
    When otherwise immediate maintenance and repair is required.




Onizuka Air Force Station                                  9                                      Asbestos Management
                                                                                                  Revised January 2006
                                                                                               Asbestos Management Plan

Renovation/Repair Projects.
    AFP 3 items: Undamaged ACM does not present an immediate exposure risk (normally f riab le asbestos).
    AFP 4 items: ACM is not damaged and poses no threat as long as it remains undamaged.

2.6.4   Categorizing Survey Findi ngs
21 SOP/ CEV will categorize survey findings using the follow criteria:

          AFP 1:    To be removed immed iately.
          AFP 2:    To be placed on schedule for abatement.
          AFP 3:    To be removed when necessary.
          AFP 4:    No action. Can remain in place.

2.6.5   Asbestos Control Options
Depending on the scope of the project, the potential health hazards identified and regulatory or Air Fo rce
requirements, one of the following asbestos control options will be imp lemented:

          Maintain in p lace: A CM is undamaged and does not pose a risk of exposure.
          Enclosure: build or spray a resilient structure/coating around ACM designed to prevent disturbance and
           contain release of fibers.
          Encapsulation: seal, coat, or wrap A CM to prevent release of asbestos fibers.
          Repair damaged material containing asbestos.
          Removal.

2.7       Regulatory Notification

Requirements for EPA, State and local abatement notification are to be included in all ACM abatement contracts as
required. Proof o f notification must be submitted to the Contracting Officer befo re the notice to proceed is issued.

2.8       Asbestos Awareness Information

General base knowledge and awareness of asbestos conditions and activities is disseminated through articles in the
base newsletter and proper labeling. 21 SOPS/ CEV is responsible for ensuring appropriate signs are placed
anywhere there is a potential for an asbestos hazard.

2.9       Training

The only type of asbestos work Onizu ka AFS employees should be doing is Class III and Class IV work. Class I
and Class II work wh ich involves removal act ivities should only be performed by an outside contractor who is
properly trained and certified. According to OSHA 29 CFS 1926.1101, Class III asbestos work includes repair and
maintenance operations where ACM and/or PA CM is likely to be disturbed. Class IV work involves maintenance
and custodial activ ities during wh ich employees contact but do not disturb ACM or PA CM and activit ies to clean up
dust, waste and debris resulting fro m Class I, II, and III activit ies. For a worker to perform Class III work, he/she
will need at a minimu m 16 hours of asbestos awareness training in order to wo rk without supervision. In order to
perform Class IV work, a worker is required at a minimu m 2 hours of training that includes location of
ACM/PACM, asbestos-containing flooring material, or flooring material where abs ence of asbestos has not be
certified, and instruction in recognition of damage, deterioration, and delamination of asbestos -containing building
materials.




Onizuka Air Force Station                                 10                                       Asbestos Management
                                                                                                   Revised January 2006
                                                                                              Asbestos Management Plan

2.10 Contract Monitoring

Abatement Contractor monitoring via personnel and area air mon itoring by a certified industrial hygienist is required
in all abatement contracts. Site inspections, reviews of abatement plans and air sampling plans are conducted by 21
SOPS/CEV.

Survey Contractor monitoring is performed by 21 SOPS/ CEV, who assures the work is performed in accordance
with the terms and scope of the survey contract. 21 SOPS/ CEV also acts as coo rdinator between tenants and the
Contractor.

2.11 Budgeting

The OASF asbestos management program cannot be effectively imp lemented without adequate resources. 21
SOPS/CEV will prepare an annual budget for asbestos -related activities by September 30 of each year. The budget
will be submitted to 21 SOPS/ CE for approval. Allocation of funds for asbestos work should be based upon this
budget. The budget should include funds for the following:

         Surveys.
         Sampling and analysis.
         Train ing.
         Contract abatement/monitoring.
         Incidental supplies.
         Fees for inspections, notificat ions, and disposal.




Onizuka Air Force Station                                   11                                   Asbestos Management
                                                                                                 Revised January 2006
                                                                                             Asbestos Management Plan


3 1993 ONIZUKA FACILITY ASBESTOS SURVEY SUMMARY
Various ACMs were identified during the facilit ies survey conducted at OAFS in 1987 and 1993. Ho wever due to
the buildings recent construction, only a few friab le ACM were identified. The most common ACM identified was
non-friable, asbestos-containing floor tile and floor tile mastic, with asbestos content ranging from trace amounts
(less than 1% by weight) to 30%. In most cases the floor tiles were in excellent condition, and the tiles and mastic
received a AF priority code of 6. Floor tile and mastic with AF prio rity code less than 6 was usually damaged and/or
friable. A su mmary o f the 1993 survey findings and asbestos removal p rojects is presented in subsequent sections.
Refer to the, Dra ft Report for the Asbestos Identification Surveys Peterson AFB and Five Supported USAF Space
Command Installations, dated August 12, 1994 for detailed informat ion and recommendations. The Asbestos Files
maintained by 21 SOPS/CEV contains detailed informat ion regarding asbestos removal projects and analysis results
of suspected ACM.

3.1     Building 1001

PES conducted an asbestos identification survey of Building 1001 between 27 April and 10 May 1993. Building
1001 is a 109,998 square foot, one story structure constructed of steel colu mn supports on a concrete slab
foundation. PES identified seven assessment areas (Table 6), 84 ho mogeneous sampling areas (HSAs) and collected
192 samples of suspect ACM. Sample locations and identified A CM are shown on drawings 0001001A/B/ C.

Roo ms 49 through 64, 120 through 125, 126, 129, and 132 had been completely renovated since 1985 and were not
included in the survey. PES reco mmended that identified A CM and suspected ACM be included in an O&M
preventive maintenance program. Table 7 lists asbestos removal projects in Build ing 1001.

AREA CODE ASSESS MENT AREA                                       AF PRIORITY
      A             Office Spaces and Common Areas                    5
      B             Overhead Spaces Above Ceilings                    2
      C             Mechanical Space 107                              5
      D             Mechanical Space 328                              3
       E            Mechanical Space 426                              4
       F            Mechanical Space 167/169                          4
      G             Mechanical Space Adjacent to Roo m 301            0
Table 6: B uil ding 1001 Assessment Areas




Onizuka Air Force Station                               12                                       Asbestos Management
                                                                                                 Revised January 2006
                                                                                              Asbestos Management Plan


DATE           LOCATION                       DES CRIPTION
2/18/93        Roo ms 110 & 401               Removed 400 sq. ft. floor t ile
6/4/93         Roo m 107                      Removed 30 linear ft expansion joints fro m AHU11
8/4/93         Roo ms 150 & 154               Removed 770 sq. ft. v inyl floor t ile
9/23/93        Roo ms 321 & 326               Removed 330 sq. ft. floor t ile
11/ 18/ 93     Roo ms 179, 306, 307, & 308    Asbestos removal overhead mech. Roo m
4/21/94        Roo ms 405, 414, & 417         Removed 935 sq. ft. carpet and tile
7/24/94        Corridors                      Removed 2,900 sq. ft. floor t ile (includes Bldg. 1003)
2/13/95        Roof                           Removed 30 ft pipe insulation
7/95           Roo m 156 (PIC Room)           Removed 5,440 sq. ft. floor t ile
12/ 14/ 95     Roo m 102                      Removed 610 sq. ft. carpet and floor tile
1995           Co mplex A                     Removed 4,500 sq. ft. carpet and floor tile
1995           Co mplex X                     Removed 1,970 sq. ft. carpet and floor tile
1995           Co mple x 7                    Removed 4,000 sq. ft. carpet and floor tile
1996           Co mplex M, Rm 493             Removed 510 sq. ft. carpet and floor tile
1996           Roo ms 324, 326, 327           Removed 672 sq. ft. carpet and floor tile
11/ 29/ 98     Roo m 111                      Removed 3,000 sq. ft. of floor tile
Table 7: Summary of Buil ding 1001 Asbestos Removal Projects

3.2     Building 1002

PES conducted an asbestos identification survey of Building 1002 on 5 -6 May 1993. Bu ild ing 1002 is a 50,560
square foot, two-story structure, constructed of steel colu mn supports with a cement exterior on a concrete slab
foundation. PES identified five assessment areas (Table 8), 33 HSAs and collected 83 samples of suspect ACM.
Sample locations and identified ACM are shown on drawing 0001002A/B.

Sections of the south and west hallways on the second floor were not inspected during PES’ survey. These areas
had been completely renovated in 1992 and were not included in PES’ inspection. PES Reco mmended that all
ACMs be included in an O&M program, wh ich includes periodic surveillance of ACM conditions, and to removed
identified friable ACM must be removed in accordance BAAQM D regulations. Table 9 lists asbestos removal
projects in Bu ild ing 1002.

AREA CODE ASSESS MENT AREA                         AF PRIORITY
      A             First Floor, East Section           2
      B             First Floor, West Section           2
      C             Second Floor, East Section          6
      D             Second Floor, West Section          6
       E            Mechanical Roo m                    0
Table 8: B uil ding 1002 Assessment Areas




Onizuka Air Force Station                               13                                       Asbestos Management
                                                                                                 Revised January 2006
                                                                                              Asbestos Management Plan


 DATE               LOCATION              DES CRIPTION
4/22/93        Roo m 550                  Removed 475 sq. ft. floor t ile
5/13/93        Roo ms 535, 537, & 539     Removed 1,375 sq. ft. floor t ile
12/ 14/ 93     Roo m 622                  Removed 322 sq. ft. carpet and tile
 5/2/95        Roo m 627                  Removed 875 sq. ft. carpet and tile
  9/95         Roo m 653                  Removed 862 sq. ft. carpet and tile
  9/95         Roo m 655                  Removed 117 sq. ft. carpet and tile
  9/95         Rm. 657                    Removed 117 sq. ft. carpet and tile
 11/ 96        Roo m 106                  Removed 1000 sq. ft. carpet and tile
  5/97         Roo m 571, 576             Removed 1000 sq. ft. carpet and tile
  6/97         Roo m 624                  Removed 100 sq. ft. floor t ile
Table 9: Summary of Buil ding 1002 Asbestos Removal Projects

3.3     Building 1003

PES conducted and asbestos identification survey of Building 1003 on 21-26 April 1993. Building 1003 is a
170,392 square foot four story building, constructed of steel colu mn supports and exterior metal panels on a concrete
slab foundation. PES identified six assessment areas, 20 HSAs and collected 49 samples of suspect ACM. Sample
locations and identified ACM are shown on drawings 0001003A -E of the PES report. Table 11 lists asbestos
removal pro jects for Bu ild ing 1003.

Several areas throughout the building could not be accessed during the asbestos survey because of security reasons.
These areas are evaluated before any renovations occur in these areas. The general reco mmendations for Building
1003 was to remove all identified potentially friab le ACM prior to renovation or demo lit ion in accordance with
BBAQM D regulat ions.

AREA CODE ASSESS MENT AREA                           AF PRIORITY
      A           First Floor                             6
      B           First Floor Mechanical Roo m            0
      C           Second Floor                            0
      D           Mezzanine Mechanical Roo m              0
       E          Third Floor                             0
       F          Fourth Floor                            0
Table 10: Buil ding 1003 Assessment Areas

DATE       LOCATION       DES CRIPTION
7/24/94    Corridors      Removed 2,900 sq. ft. floor t ile (includes Bldg. 1001)
Table 11: Summary of Buil ding 1003 As bestos Removal Projects


3.4     Building 1004

PES conducted an asbestos survey of Building 1004 on 19 April 1993. Building 1004 is a 23,240 square foot, two
story structure, which was constructed in 1959. The build ing was constructed of steel support columns with metal
siding on a concrete slab foundation. PES identified six assessment areas and 13 HSAs (HSAs 7, 8, and 14-17 were
not used) and collected 37 samples of suspect ACM. Assessment areas C and F were additions to the building after
1985 and were not included in PES’ inspection. Sample locations and identified ACM are shown on drawings
0001001A/B of the PES report.




Onizuka Air Force Station                               14                                       Asbestos Management
                                                                                                 Revised January 2006
                                                                                              Asbestos Management Plan

PES reco mmended sampling of asbestos-containing transite paneling in area A and suspected insulation on a boiler
stack in area D. PES also gave the general reco mmendation to include any ACM in an O&M program and that prior
to renovation or demolition, all identified friable and potentially friable A CM must be removed in accordance with
BAAQMD regulations.

AREA CODE             ASSESS MENT AREA                 AF PRIORITY
A                     First Floor, Main Plant Area     6
B                     First Floor Offices              0
C                     First Floor EUB Area             0
D                     Second Floor, Main Plan Area     6
E                     Second Floor Offices             6
F                     Second Floor EUB                 0
Table 12: Buil ding 1004 Assessment Areas

3.5     Building 1005

PES conducted an asbestos identification survey of Building 1005 on 20 April 1993. Bu ilding 1005, built in 1974,
is a 12,400 square foot, one story structure with a mezzanine mechanical room, constructed of steel column supports
with metal sliding on a concrete foundation. PES identified five assessment areas and 14 HSAs (HSA 10 was not
used during the survey) and collected 42 samp les of suspect ACM. Samp le locations and identified A CM are shown
on drawing 0001005A of the PES report.

PES reco mmended that prior to renovation or demo lit ion, all potentially friab le A CM must be removed in
accordance with BAAQM D regulat ions.

AREA CODE ASSESS MENT AREA                                          AF PRIORITY
      A           Warehouse/Stock Area                                   0
      B           Local Warehouse                                        6
      C           Mezzanine Mechanical Area in Roo m 811                 0
      D           Security/Co mputer Support                             6
       E          Motor Pool/Travel Office                               0
Table 13: Buil ding 1005 Assessment Areas

DATE        LOCATION                   DES CRIPTION
6/97        Roo ms 811, 812            Removed 2,040 sq. ft. of floor tile
7/97        Roo ms 802, 803, 813       Removed 1600 sq. ft. of floor tile

Table 14: Summary of Buil ding 1005 As bestos Removal Projects

3.6     Building 1006

PES conducted an asbestos survey of Building 1006 on 16 April 1993. Building 1006 is a 6,700 square foot, one-
story structure built in 1971 of steel colu mns with alu minum siding on a concrete slab. PES identified four
assessment areas and 9 HSAs (HSA 7 was not used during the survey) and collected 23 samp les of suspect ACM.
Sample locations are shown on drawing 0001006A of the PES report.




Onizuka Air Force Station                                 15                                      Asbestos Management
                                                                                                  Revised January 2006
                                                                                              Asbestos Management Plan


AREA CODE             ASSESS MENT AREA                                AF PRIORITY
    A                 Lobby/Dining Area/MWR Office/ Rest Roo ms            0
    B                 Kitchen                                              0
    C                 Mechanical Roo m                                     0
    D                 Bar/Stock Area                                       0
Table 15: Buil ding 1006 Assessment Areas

3.7     Building 1010

PES conducted an asbestos identification survey of Building 1010 on 4 May 1993. Build ing 1010 is a 998 square
foot, one-story structure, which was constructed in 1977. Bu ild ing 1010 p rovides ground communicat ion support to
Building 1016, which is a satellite antenna. PES identified two assessment areas and five HSAs. PES co llected 8
samples of suspect ACM. Samp le locations and identified ACM are shown on drawing 0001010A of the PES
report. PES reco mmended that prior to renovation or demolition, all potentially friable ACM must be removed in
accordance with BAAQM D regulat ions.

AREA CODE             ASSESS MENT AREA         AF PRIORITY
    A                 Interior Office Areas         6
    B                 Mechanical Roo m              0
Table 16: Buil ding 1010 Assessment Areas


3.8     Building 1013

PES surveyed Building 1013 on 21 April 1993. Bu ild ing 1013 is a 10,666 square foot, one -story structure,
constructed in 1977 of steel colu mns with metal sid ing on a concrete slab. The building provides ground support to
Building 1009 and 1012 (satellite antennas). PES identified five assessment areas and 17 HSAs. PES collected 41
samples of suspect ACM. Samp le locations and identified ACM are shown on drawing 0001013A of the PES
report. PES reco mmended that ACM in the build ing be included in an O&M Program and that prior to renovation
or demo lit ion, all potentially friable A CM must be removed in accordance BAAQMD regulations.

AREA CODE ASSESS MENT AREA                                    AF PRIORITY
      A           Unsecured Office Areas                           6
      B           Tech Support Offices and Break Roo m             0
      C           Co mmunicat ion Equip ment Roo m                 0
      D           Crypto Offices                                   6
       E          Mechanical Roo m                                 0
Table 17: Buil ding 1013 Assessment Areas


3.9     Buildings 1018, 1020, 1026 and 1003-2

A Facility Su mmary Report was not provided for Buildings 1018, 1020, 1026 and 1003-2. However, the Asbestos
Survey Su mmary Narrative fo r buildings 1018,1020 and 1026 lists the Air Force Prio rity for all assessment areas as
a 6. The assessment areas for Building 1003-2 (Entire Second Level Parking Garage) were listed as 0.




Onizuka Air Force Station                               16                                       Asbestos Management
                                                                                                 Revised January 2006