VERITAS i3 _tm_ version 7.1.x - Patches Status

Document Sample
VERITAS i3 _tm_ version 7.1.x - Patches Status Powered By Docstoc
					VERITAS Software Corporation




VERITAS i3™ version 7.1.x - Patches Status for 08-Aug-2005
                                                                                                   3
This document provides a short description of all the patches that are released for VERITAS™ i version
7.1.
Note: The release date is the official date R&D is due to release the patch. The release date means that
the patch is ready and may be sent to customers, as required. The actual day the Patch is available on the
support Web site is a few days following the R&D release date.
Each Patch can be in one of the following statuses:
    1. Published - Patch is officially published – Please notice that in this state you can click on the patch
       number and navigate to its corresponding TechNote.
    2. Rejected – Patch was officially published and then due to problems was pulled out.
    3. Obsolete – Patch was made obsolete by the release of a newer patch.
    4. Published(b) - Patch is officially published as part of a Bundle patch


Patch ID Conventions

Version 7.1 has introduced an enhanced convention for patch IDs. Its purpose is to provide more details on
the component(s) of the patch and the fixes or enhancements the patch was developed for. A description of
the new convention and examples to help you get started, are provided below.
A Patch ID is a sequence of letters and digits used to uniquely identify a patch. This ID is used in naming
the patch's packages and the patch's manifest file. The format of the patch ID is separated into four
segments ―PP_CCCC<C>_710_XXX‖ (each segment is separated by an underline) as follows:


   PP - Signifies the product code. The following is the list of codes and their relative products:

         IN—i3 Infrastructure patch (i3 FocalPoint, i3 Basic agent, Agent Installer, AdminPoint, etc.)
         PW—Performance Warehouse
         UI—i3 UI (can be for a specific Product or for general purposes such as AdminPoint,
          AgentInstaller, etc.)
         PF—Inform/Alerts
         FS— Inform/Foresight
         IS—Insight
         OR—Indepth/Oracle
         JE—Indepth/J2EE
         WW—Indepth/Web
         SQ—Indepth/SQL Server
         SP—Indepth/SAP
         MP—Multiple Products, if the patch is relevant to more than one product




                                                   3
                                     VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


   CCCC<C> - The next four to five characters specify which of the relevant agents were fixed in this
    patch. The following options are available:

         Patch for a product’s FocalPoint—specified by the product code followed by ―FP‖. For example,
                          3
          INFP signifies i FocalPoint; ORFP signifies Indepth/Oracle Focal Point.
         Patch for a single agent of a product—specified by the product code followed by three digits
          representing the agent's code. For example, ORCOL for Indepth/Oracle collector; SQCOL for
          Indepth/SQL Server Collector.
         Patch for Multiple agents (more than one)—specified by MUAGS. For details on which agents
          were fixed, check the manifest.
         Patch for the product’s FocalPoint and a single agent)—specified by FPAG. For details on which
          agents were fixed, check the manifest.
         Patch for the product’s FocalPoint and Multiple Agents)—specified by FPAGS. For details on
          which agents were fixed, check the manifest.

                                                                                   3
    710 - The next three characters contain a three-digit number representing the i version that the patch
    belongs to (for example, - 710 represents version 7.1).


   XXX - The next three characters contain a three-digit sequence number that uniquely identifies this
                                                            3
    patch among all the product’s patches for the relevant i version. Please notice that a sequence of
    patches is per product and not per product agents.

Examples of patch IDs:

                                                            3
    UI_GUIFP_710_001—Patch number 1 for the UI of the i GUI, installed on the FocalPoint server.
   OR_ORCOL_710_003—Patch number 3 for Indepth/Oracle that provides fixes for the Indepth/Oracle
    Collector.
   IS-MUAGS-710-002—Patch number 2 for Insight that contain fixes or enhancements for Insight agents.




                                                 3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation



Bundle Patch Releases

The upcoming releases of patches for the VERITAS i3 ™ 7.1.x is going to be done by a new mechanism
that will bundle all products patches into a one delivery. The term that is used to this bundle mechanism is
Bundle Patch Release. The released of each Bundle Patch Release will include in it all the enhancements
and fixes that were released in the predecessor Bundle Patch making the previous Bundle Patch obsolete.
The current table will list for each Bundle Patch the content of all patches that will are part of this bundle.
For the installations of a Bundle patch you must first download and install the following VERITAS i3 (tm)
patches: VERITAS i3 (tm) 7.1 - Patch IN_INFP_710_008 and VERITAS i3 (tm) 7.1 - Patch UI_GUIFP_710_011

For information on how to install Bundle patches, refer to VERITAS i3 (tm) 7.1 - Bundle Patch Administration Guide


       Bundle Patch                                             Content of Patches
                                     i3                      - IN_INBA_710_009 (Obsolete, 20-Jun-2005)
                                     PW                      - PW_PWFP_710_005 (Obsolete, 20-Jun-2005)
                                     Inform for Alerts       - PU_PUPNT_710_005 (Published(b), 20-Jun-2005)
                                     Inform for Alerts       - PF_PFFP_710_004 (Published(b), 20-Jun-2005)
                                     Inform for Foresight    - FS_FSFP_710_003 (Obsolete, 15-Feb-2005)
                                     Insight                 - IS_ISFP_710_010 (Obsolete, 20-Jun-2005)

        BU_I3_710_001                Insight                 - IS_MUAGS_710_011 (Obsolete, 20-Jun-2005)
    (Obsolete, 20-Jun-2005)          Indepth for Oracle      - OR_FPAGS_710_009 (Obsolete, 23-May-2005)
                                     Indepth for J2EE        - JE_FPAG_711_003 (Published(b), 11-May-2005)
                                     Indepth for Web         - WW_FPAGS_710_004 (Published(b), 20-Jun-2005)
                                     Indepth for SQL Server - SQ_FPAGS_710_004 (Published(b), 25-Apr-2005)
                                     Indepth for SAP         - SP_SPFP_710_003 (Published(b), 20-Jun-2005)


                                 Comments:
                                 None




                                                          3
                                        VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation




                                 i3                      - IN_FPAGS_710_010 (Published(b), 22-Jul-2005)
                                 GUI                     - UI_GUIFP_710_012 (Published(b), 22-Jul-2005)
                                 PW                      - PW_PWFP_710_006 (Published(b), 22-Jul-2005)
                                 Inform for Alerts       - PU_PUPNT_710_005 (Published(b), 20-Jun-2005)
                                 Inform for Alerts       - PF_PFFP_710_004 (Published(b), 20-Jun-2005)
                                 Inform for Foresight    - FS_FSFP_710_004 (Published(b), 22-Jul-2005)
                                 Insight                 - IS_ISFP_710_012 (Published(b), 22-Jul-2005)
                                 Insight                 - IS_MUAGS_710_013 (Published(b), 22-Jul-2005)
                                 Insight                 - IS_MUAGS_710_014 (Published(b), 22-Jul-2005)
       BU_I3_710_002             Indepth for Oracle      - OR_ORFP_710_010 (Published(b), 22-Jul-2005)
   (Published, 04-Aug-2005)
                                 Indepth for Oracle      - OR_ORCOL_710_011 (Published(b), 22-Jul-2005)
                                 Indepth for Oracle      - OR_ORNLS_710_012 (Published(b), 22-Jul-2005)
                                 Indepth for .NET        - DN_FPAG_710_001 (Published(b), 22-Jul-2005)
                                 Indepth for J2EE        - JE_FPAG_711_003 (Published(b), 11-May-2005)
                                 Indepth for Web         - WW_FPAGS_710_004 (Published(b), 20-Jun-2005)
                                 Indepth for SQL Server - SQ_FPAGS_710_004 (Published(b), 25-Apr-2005)
                                 Indepth for SAP         - SP_SPFP_710_003 (Published(b), 20-Jun-2005)


                              Comments:
                              Including the release of VERITAS Indepth ™ for Microsoft .NET 7.1




                                                      3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation



List of Patches
Click on their titles in order to navigate to the list of the patches available for the product. Click on a specific
patch to get to its details (in this document). For each patch in parenthesis appear the current state the
patch it’s release date. Recommended patches for each of the products and the i3 Framework are marked
with a red bold star (*).

   i3                                                           Insight
    o     *IN_FPAGS_710_010 (Published(b), 22-Jul-2005)           o   *IS_MUAGS_710_014 (Published(b), 22-Jul-2005)
    o      IN_INBA_710_009 (Obsolete, 20-Jun-2005)                o   *IS_MUAGS_710_013 (Published(b), 22-Jul-2005)
    o     *IN_INFP_710_008 (Published, 20-Jun-2005)               o   *IS_ISFP_710_012 (Published(b), 22-Jul-2005)
    o      IN_INBA_710_007 (Obsolete, 30-Mar-2005)                o    IS_MUAGS_710_011 (Obsolete, 20-Jun-2005)
    o      IN_INFP_710_006 (Obsolete, 30-Mar-2005)                o    IS_ISFP_710_010 (Obsolete, 20-Jun-2005)
    o      IN_INFP_710_003 (Obsolete, 1-Feb-2005)                 o    IS_MUAGS_710_009 (Obsolete, 6-May-2005)
    o      IN_INFP_710_001 (Obsolete, 2-Dec-2004)                 o    IS_MUAGS_710_008 (Obsolete, 15-Apr-2005)
   PW                                                            o    IS_ISFP_710_007 (Obsolete, 15-Apr-2005)
    o     *PW_PWFP_710_006 (Published(b), 22-Jul-2005)            o    IS_ISTUX_710_006 (Obsolete, 10-Feb-2005)
    o      PW_PWFP_710_005 (Obsolete, 20-Jun-2005)                o    IS_ISOS_710_005 (Obsolete, 15-Feb-2005)
    o      PW_PWFP_710_004 (Obsolete, 28-Feb-2005)                o    IS_ISTCP_710_004 (Obsolete, 16-Jan-2005)
    o      PW_PWFP_710_003 (Rejected, 15-Feb-2005)                o    IS-ISOS-710-003 (Obsolete, 12-Dec-2004)
    o      PW_PWFP_710_002 (Published, 06-Feb-2005)               o    IS-MUAGS-710-002 (Obsolete, 01-Nov-2004)
    o      PW_PWFP_710_001 (Obsolete, 1-Dec-2004)                 o    IS-ISFP-710-001 (Obsolete, 01-Nov-2004)

   GUI                                                          Indepth for Oracle
    o     *UI_GUIFP_710_012 (Published(b), 22-Jul-2005)           o   *OR_ORNLS_710_012 (Published(b), 22-Jul-2005)
    o     *UI_GUIFP_710_011 (Published, 20-Jun-2005)              o   *OR_ORCOL_710_011 (Published(b), 22-Jul-2005)
    o      UI_GUIFP_710_008 (Obsolete, 30-Mar-2005)               o   *OR_ORFP_710_010 (Published(b), 22-Jul-2005)
    o      UI_GUIFP_710_006 (Obsolete, 10-Feb-2005)               o    OR_FPAGS_710_009 (Obsolete, 23-May-2005)
    o      UI_GUIFP_710_005 (Obsolete, 1-Feb-2005)                o    OR_FPAG_710_008 (Obsolete, 15-Apr-2005)
    o      UI_GUIFP_710_004 (Obsolete, 9-Jan-2005)                o    OR_FPAG_710_007 (Obsolete, 31-Jan-2005)
    o      UI_GUIFP_710_003 (Obsolete, 21-Dec-2004)               o    OR_FPAG_710_006 (Obsolete, 17-Jan-2005)
    o      UI_GUIFP_710_002 (Obsolete, 16-Dec-2004)               o    OR_ORFP_710_005 (Published, 3-Apr-2005)
    o      UI_GUIFP_710_001 (Obsolete, 01-Nov-2004)               o    OR_ORCOL_710_004Z (Obsolete, 05-Dec-2004)
   Inform for Alerts                                             o    OR_ORCOL_710_003 (Obsolete, 01-Nov-2004)
    o     *PU_PUPNT_710_005 (Published(b), 20-Jun-2005)           o    OR_ORFP_710_002 (Obsolete, 01-Nov-2004)

    o     *PF_PFFP_710_004 (Published(b), 20-Jun-2005)           Indepth for J2EE
    o      PF_PFFP_710_003 (Obsolete, 21-Feb-2005)                o   *JE_FPAG_711_003 (Published(b), 11-May-2005)
    o      PF-PFFP-710-002 (Obsolete, 21-Dec-2004)                o    JE_FPAG_711_002 (Obsolete, 31-Jan-2005)
    o      PF-PFFP-710-001 (Obsolete, 11-Nov-2004)                o    JE-JECOL-710-001 (Obsolete , 10-Nov-2004)

   Inform for Foresight                                         Indepth for Web
    o     *FS_FSFP_710_004 (Published(b), 22-Jul-2005)            o   *WW_FPAGS_710_004 (Published(b), 20-Jun-2005)
    o      FS_FSFP_710_003 (Obsolete, 15-Feb-2005)                o    WW_WWAGS_710_003 (Obsolete, 16-Feb-2005)
    o      FS_FSFP_710_001 (Obsolete, 29-Nov-2004)                o    WW_WWAGS_710_002 (Obsolete, 16-Feb-2005)
                                                                  o    WW_WWFP_710_001 (Obsolete, 16-Feb-2005)
                                                                 Indepth for SQL Server
                                                                  o   *SQ_FPAGS_710_004 (Published(b), 25-Apr-2005)
                                                                  o    SQ_FPAGS_710_003 (Rejected, 15-Apr-2005)
                                                                  o    SQ_SQCOL_710_002 (Obsolete, 9-Feb-2005)
                                                                  o    SQ_MUAGS_710_001 (Obsolete, 15-Dec-2004)




                                                          3
                                          VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Indepth for SAP
                                                  o   *SP_SPFP_710_003 (Published(b), 20-Jun-2005)
                                                  o    SP_SPFP_710_002 (Obsolete, 28-Feb-2005)
                                                  o    SP_SPFP_710_001 (Rejected, 10-Feb-2005)
                                                 Indepth for .NET
                                                  o   *DN_FPAG_710_001 (Published(b), 22-Jul-2005)




                                          3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation



The following table provides description for the bundle patches:

                                   Release
  Bundle Patch ID      Status                                           Description
                                    Date
 BU_I3_710_001        Obsolete    20-Jun-2005
                      by Bundle                 The Bundle Patch is a new mechanism that enables the
                      Patch                     automatic installation of a set of required patches on
                      BU_I3_71                  the customer's environment. The installation order is
                      0_002
                                                controlled and monitored by the Bundle Patch
                                                mechanism. Detailed information on this mechanism,
                                                can be found in the Bundle Patch Administration Guide.

                                                Bundle Patch Content

                                                The Bundle Patch contains two types of patches. The
                                                first type are new patches, first released as part of this
                                                bundle. The second type are patches released as
                                                separate patches, before the Bundle Patch release and
                                                are now incorporated in the bundle.

                                                         The following is a list of all new patches
                                                          released as part of the bundle:

                                                          IN_INBA_710_009 - This patch includes fixes
                                                                           3
                                                          for the VERITAS i Listener agent.

                                                          PW_PWFP_710_005 - A cumulative patch that
                                                          contains fixes for the Load Performance Data,
                                                          Purge, Maintenance, Summary Data,
                                                          Scheduler, and Calculate Baseline processes
                                                          and the verification of the Performance
                                                          Warehouse FocalPoint.

                                                          PF_PFFP_710_004 - Fixes the settings of
                                                          several Inform/Alerts metrics and solves
                                                          problems in creating and updating customized
                                                          metrics.

                                                          PU_PUPNT_710_005 - Solves the scalability
                                                          problems that may be encountered in large
                                                          installations with many Inform/Alerts
                                                          InformPoint agents.

                                                          IS_ISFP_710_010 - Fixes several problems
                                                          in Insight and is mandatory if Insight/SmartLink
                                                          is enabled.

                                                          IS_MUAGS_710_011 - Cumulative patch that
                                                          contains enhancements and fixes problems in
                                                          Insight agents for the following AppTiers: MQ,
                                                          Oracle Applications, J2EE, Tuxedo, Network,
                                                          and OS.




                                                  3
                                     VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                           Description
                                 Date
 BU_I3_710_001     Obsolete    20-Jun-2005
                   by Bundle                           WW_FPAGS_710_004 - A cumulative patch that
                   Patch                               contains all enhancements and problem fixes
                   BU_I3_71                            from previously released Indepth/Web patches.
                   0_002
                                                       It also contains enhancements and solutions
                                                       for problems in the Indepth/Web server-side
                                                       Collector agent, client-side Collector agent,
                                                       Indepth/Web FocalPoint and Indepth/Web
                                                       AppTier installations.

                                                       SP_SPFP_710_003 - Solves some problems in
                                                       Indepth/SAP.

                                                      The following is a list of all patches that were
                                                       already released and are now incorporated in
                                                       the bundle (they can only be downloaded and
                                                       installed via this Bundle Patch):

                                                       SQ_FPAGS_710_004 - A cumulative patch. It
                                                       adds support for SQL Server 2005 and solves
                                                       problems in the Explain and Warehouse
                                                       Processes, fixes Collector agent errors, EMC
                                                       Storage problems with Clariion, Migration
                                                       problems and various user interface problems.

                                                       FS_FSFP_710_003 - Adds the ability to send
                                                       reports by email with Japanese attachments
                                                       and contains several problem fixes in for Alerts,
                                                       Web, SQL, and Oracle reports.

                                                       OR_FPAGS_710_009 - Contains various
                                                       enhancements and problem fixes for the
                                                       Indepth/Oracle Collector and FocalPoint agent.
                                                       It also adds support for installing the Siebel
                                                       Interpoint Collector agent in an Indepth/Oracle
                                                       environment.

                                                       JE_FPAG_711_003 - Cumulative patch for
                                                       J2EE with fixes and enhancements, such as
                                                       new Adaptive Instrumentation policies.

                                             For more details on each of the individual patch
                                             contents, use the Patch ID field at the top of Apply
                                             New Patch - Patch Description to select a patch.
                                             Viewing the contents of a patch within a bundle, is for
                                             viewing purposes only. You can not install the individual
                                             patch.




                                               3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                           Description
                                 Date
 BU_I3_710_001     Obsolete    20-Jun-2005
                   by Bundle                 Bundle Patch Guidelines
                   Patch
                   BU_I3_71                           If your environment is SQL Server-based, you
                   0_002                               must install the Bundle Patch on the servers
                                                       that are installed with various VERITAS
                                                       FocalPoints first. Afterwards install it on the
                                                                         3
                                                       other VERITAS i servers with AppTier agents.

                                                      The Bundle Patch mechanism will display all
                                                       Pre-Patch requirements for all individual
                                                       patches to be installed in the environment. It is
                                                       highly recommended that you will use View in
                                                       Browser at this stage, and save the action
                                                       items for later reference. Some of these action
                                                       items are dynamically calculated and displayed
                                                       and there is no possibility to view them at a
                                                       later stage.

                                                      Once the installation has been performed, the
                                                       Bundle Patch mechanism will present all Post-
                                                       Patch requirements for all individual installed
                                                       patches in the environment. Again it is highly
                                                       recommended to use View in Browser at this
                                                       stage, and save the action items for later
                                                       reference. Some of these action items are
                                                       dynamically calculated and displayed and there
                                                       is no possibility to view them at a later stage.

                                                      In case the following error message appears
                                                       during the installation process:

                                                       Unable to extract distribution
                                                       file. Extracting the file returned
                                                       an error that might have been
                                                       caused by locked files.

                                                       Check which process is locking the
                                                       files, stop the process, and retry
                                                       the operation. If the problem
                                                       persists, generate support file and
                                                       contact VERITAS Technical Support.
                                                       Include the following information:

                                                       Distribution file: %file-name%

                                                       Details: %internal%

                                                       Choose the retry option. If you do not choose
                                                       this option, the Bundle Patch installation may
                                                       fail or cause an incorrect product behavior.




                                               3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                         Description
                                 Date
 BU_I3_710_001     Obsolete    20-Jun-2005
                   by Bundle                 Notes
                   Patch
                   BU_I3_71                          The Bundle Patch can not be installed using
                   0_002                                               3 tm
                                                      the VERITAS i Command Line Interface
                                                      (CLI) utility. For more information on how to
                                                                                  3
                                                      implement the VERITAS i CLI in your
                                                      environment, contact VERITAS Technical
                                                      Support.

                                                  
                                                                                   3
                                                      If a server, a new VERITAS i product and/or a
                                                                                               3
                                                      new technology is added to the VERITAS i
                                                      system, the Bundle Patch should be applied to
                                                      that server.

                                                      Note: Even if the Bundle Patch had been
                                                      applied to the server before, you will now have
                                                      to reapply the bundle to that server.

                                                  2. When applying this patch to Linux servers,
                                                     which are not supported by Insight agents and
                                                                                              3
                                                     are not already part of your VERITAS i
                                                     installation, perform the following procedure
                                                     before you continue with this patch installation:

                                                  1. Close the patch installation dialog.

                                                  2. Use the Agent Installer to add the Linux servers
                                                     you wish to monitor without the Insight OS and
                                                     Insight Network Add-Ons.

                                                  3. Close the Agent Installer and install the patch
                                                     on all of those servers.

                                                  4. Use the Agent Installer and edit the server
                                                     properties (add the Insight OS and/or Insight
                                                     Network Add-Ons).

                                                  1. This Bundle Patch contains enhancements and
                                                                                            3
                                                      changes applicable to the VERITAS i v7.1.x
                                                      Support Matrix. For the complete information
                                                                                                  3
                                                      on platform support, refer to the VERITAS i
                                                      v7.1.x Support Matrix.




                                              3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                       Description
                                 Date
 BU_I3_710_001     Obsolete    20-Jun-2005
                   by Bundle                 Obsolete
                   Patch
                   BU_I3_71                  The Bundle Patch includes cumulative patches, which
                   0_002                     include all updates and fixes from the following
                                             patches: IN_INFP_710_007, PW_PWFP_710_004,
                                             PF_PFFP_710_003, IS_ISFP_710_007,
                                             IS_MUAGS_710_008, IS_MUAGS_710_009,
                                             SP_SPFP_710_002, WW_WWFP_710_001,
                                             WW_WWAGS_710_002 and WW_WWAGS_710_003 (and
                                             their predecessors), making those patches obsolete.




                                               3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                           Description
                                 Date
 BU_I3_710_002-    Published   04-Aug-2005
 Part_1                                      The Bundle Patch is a mechanism that enables the
                                             automatic installation of a set of required patches on
 BU_I3_710_002-                              the customer's environment. The installation order is
 Part_2                                      controlled and monitored by the Bundle Patch
                                             mechanism. Detailed information on this mechanism,
                                             can be found in the Bundle Patch Administration Guide.
                                             Important

                                             Before the installation of the Bundle Patch you must
                                                                                                3
                                             first download and install the following VERITAS i
                                             patches:

                                                   2. Patch IN_INFP_710_008

                                                   3. Patch UI_GUIFP_710_011
                                             Bundle Patch Content

                                             The Bundle Patch contains two types of patches. The
                                             first type is new patches, first released as part of this
                                             bundle. The second type is patches released as part of
                                             Bundle Patch 01.

                                                   2. The following is a list of all new patches
                                                       released as part of the bundle:

                                             IN_FPAGS_710_010 - This is a cumulative patch that
                                                                                           3
                                             improves the performance of the VERITAS i
                                             AdminPoint and Agent Installer. It also contains
                                                                                        3
                                             improvements and fixes for the VERITAS i FocalPoint,
                                                                                          3
                                             VERITAS i3 Listener agent, and VERITAS i Command
                                             Line Interface (CLI) utility.

                                             PW_PWFP_710_006 - This patch contains changes in
                                             the Performance Warehouse schema in order to
                                             support Citrix monitoring.

                                             UI_GUIFP_710_012 - This patch adds support for the
                                             Indepth/.NET Framework and .NET AppTier
                                             installation.

                                             FS_FSFP_710_004 - This cumulative patch contains
                                             several problem fixes for Web, J2EE, SQL, and Oracle
                                             reports.

                                             IS_ISFP_710_012 - This cumulative patch adds
                                             support for SmartLink based on an SQL Server
                                             Performance Warehouse and Citrix monitoring, and
                                             also fixes several problems in Insight FocalPoint.




                                               3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                           Description
                                 Date
 BU_I3_710_002-    Published   04-Aug-2005
 Part_1                                      IS_MUAGS_710_013 - This is a cumulative patch that
                                             contains enhancements and fixes problems in Insight
 BU_I3_710_002-                              agents for the following AppTiers: MQ, Oracle
 Part_2                                      Applications, J2EE, Tuxedo, Network, and OS.

                                             IS_MUAGS_710_014 - Update of the installation kits
 (cont.)
                                             for Insight agents.

                                             OR_ORFP_710_010 - This cumulative patch contains
                                             various enhancements and problem fixes for the
                                             Indepth/Oracle FocalPoint agent.

                                             OR_ORCOL_710_011 - This cumulative patch contains
                                             various enhancements and problem fixes for the
                                             Indepth/Oracle Collector agent.

                                             OR_ORNLS_710_012 - This patch contains Oracle
                                             client libraries for the support of the
                                             NLS_CHARACTERSET, introduced in Oracle 9.

                                             DN_FPAG_710_001 - This patch contains the full
                                             release of Indepth/.NET.

                                                      The following is a list of all patches that were
                                                       already released in Bundle Patch 01 and are
                                                       now incorporated in the Bundle Patch 02 (they
                                                       can only be downloaded and installed via this
                                                       Bundle Patch):

                                             SQ_FPAGS_710_004 - This is a cumulative patch. It
                                             adds support for SQL Server 2005 and solves problems
                                             in the Explain and Warehouse Processes, fixes
                                             Collector agent errors, EMC Storage problems with
                                             Clariion, Migration problems and various user interface
                                             problems.

                                             JE_FPAG_711_003 - This is a cumulative patch for
                                             J2EE with fixes and enhancements, such as new
                                             Adaptive Instrumentation policies.

                                             WW_FPAGS_710_004 - This patch is a cumulative
                                             patch that contains all enhancements and problem fixes
                                             from previously released Indepth/Web patches. It also
                                             contains enhancements and solutions for problems in
                                             the Indepth/Web server-side Collector agent, client-side
                                             Collector agent, Indepth/Web FocalPoint and
                                             Indepth/Web AppTier installations.

                                             SP_SPFP_710_003 - This patch solves some
                                             problems in Indepth/SAP.




                                               3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                          Description
                                 Date
 BU_I3_710_002-    Published   04-Aug-2005
 Part_1                                      PF_PFFP_710_004 - This patch fixes the settings of
                                             several Inform/Alerts metrics and solves problems in
 BU_I3_710_002-                              creating and updating customized metrics.
 Part_2
                                             PU_PUPNT_710_005 - This patch solves the scalability
 (cont.)                                     problems that may be encountered in large installations
                                             with many Inform/Alerts InformPoint agents.

                                             For more details on each of the individual patch
                                             contents, use the Patch ID field at the top of Apply
                                             New Patch - Patch Description to select a patch.
                                             Viewing the contents of a patch within a bundle, is for
                                             viewing purposes only. You can not install the individual
                                             patch.

                                             Bundle Patch Guidelines

                                                      It is highly recommended to install the Bundle
                                                                                    3
                                                       Patch on all the VERITAS i servers. If you only
                                                       want to install it on some of the servers, you
                                                       must make sure that the first installation of the
                                                       Bundle Patch includes all servers that contain
                                                                   3
                                                       VERITAS i FocalPoints.

                                                      The Bundle Patch mechanism will display all
                                                       Pre-Patch requirements for all individual
                                                       patches to be installed in the environment. It is
                                                       highly recommended that you will use View in
                                                       Browser at this stage, and save the action
                                                       items to a file for later reference. Some of
                                                       these action items are dynamically calculated
                                                       and displayed and there is no possibility to view
                                                       them at a later stage.




                                               3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                         Description
                                 Date
 BU_I3_710_002-    Published   04-Aug-2005
 Part_1                                             Once the installation has been performed, the
                                                     Bundle Patch mechanism will present all Post-
 BU_I3_710_002-                                      Patch requirements for all individual installed
 Part_2                                              patches in the environment. Again it is highly
                                                     recommended to use View in Browser at this
 (cont.)                                             stage, and save the action items to a file for
                                                     later reference. Some of these action items are
                                                     dynamically calculated and displayed and there
                                                     is no possibility to view them at a later stage.

                                                     Note

                                                     During the Bundle Patch installation, ALL
                                                                  3
                                                     VERITAS i components (FocalPoint and
                                                     agents) that need to be stopped during the
                                                     installation of the bundle, will automatically be
                                                     stopped. This may include components
                                                     indirectly influenced by the actions of the
                                                                                        3
                                                     Bundle Patch on the VERITAS i servers that
                                                     are not patched. You will be asked to restart all
                                                                        3
                                                     these VERITAS i components after the Bundle
                                                     Patch installation has finished.

                                                    If the following error message appears during
                                                     the installation process:

                                                     Unable to extract distribution
                                                     file. Extracting the file returned
                                                     an error that might have been
                                                     caused by locked files.

                                                     Check which process is locking the
                                                     files, stop the process, and retry
                                                     the operation. If the problem
                                                     persists, generate support file and
                                                     contact VERITAS Technical Support.
                                                     Include the following information:

                                                     Distribution file: %file-name%

                                                     Details: %internal%

                                                     Choose the retry option. If you do not choose
                                                     this option, the Bundle Patch installation may
                                                     fail or cause an incorrect product behavior.




                                             3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                Release
 Bundle Patch ID    Status                                           Description
                                 Date
 BU_I3_710_002-    Published   04-Aug-2005
 Part_1                                                If the following error message appears during
                                                       the installation process:
 BU_I3_710_002-
 Part_2                                                The file SQ_GUIFP_710_004_All.zip
                                                       already exists on the remote server
                                                       <server name> and its size is
 (cont.)                                               different (Target file size on the
                                                       remote server is: <size> Source
                                                       file size is: <size> ).
                                                       Would you like to replace the
                                                       existing file with the updated one?

                                                       Choose the option Yes to All.

                                             Notes

                                                      The Bundle Patch can not be installed using
                                                                       3
                                                       the VERITAS i Command Line Interface (CLI)
                                                       utility. For more information on how to
                                                                                   3
                                                       implement the VERITAS i CLI utility in your
                                                       environment, contact VERITAS Technical
                                                       Support.

                                                   
                                                                                             3
                                                       If a server is added to the VERITAS i system,
                                                       the Bundle Patch must be applied to that
                                                       server.

                                                   
                                                                          3
                                                       If a new VERITAS i product and/or a new
                                                                                           3
                                                       technology is added to the VERITAS i system,
                                                       the Bundle Patch must be reapplied to the
                                                       relevant server.

                                                       Note

                                                       The patch installation screen will not inform you
                                                       to reapply the Bundle Patch. Even if it is
                                                       marked as "Successfully Installed", you must
                                                       reapply the patch.

                                                      This Bundle Patch contains enhancements and
                                                                                            3
                                                       changes applicable to the VERITAS i v7.1.x
                                                       Support Matrix. For the complete information
                                                                                                   3
                                                       on platform support, refer to the VERITAS i
                                                       v7.1.x Support Matrix.

                                             Obsolete

                                             The Bundle Patch includes cumulative patches, which
                                             include all updates and fixes from Bundle Patch
                                             BU_I3_710_001, making that patch, its included
                                             patches and their predecessors obsolete.




                                               3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


The following table provides a brief description of the patches available:
                                                        Release
  Product             Patch ID             Status                                 Description
                                                         Date

 i3          IN_INFP_710_001             Obsolete by    2-Dec-    This patch adds the following features
                                         patch          2004
                                                                  to the version:
                                         IN_INFP_71
                                         0_003                              Enables mass upgrade of
                                                                             servers & Oracle instances
                                                                             from version 6.x.

                                                                            Improves the AdminPoint
                                                                             support files mechanism by
                                                                             allowing servers filltering in
                                                                             express and full modes.

                                                                  Important: This patch requires
                                                                  installation of patch IN6xx710U on the
                                                                  version 6.xx i3 FocalPoint.




                                                    3
                                     VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                             Description
                                                  Date

 i3         IN_INFP_710_003       Obsolete by    1-Feb-    This patch adds the following
                                  patch          2005
                                                           features:
                                  IN_INFP_71
                                  0_006                           Ability to mass-upgrade
                                                                   Indepth/J2EE AppTier
                                                                   instances from version 6.2.1.

                                                               
                                                                              3
                                                                   VERITAS i Command Line
                                                                   Interface (CLI)
                                                                                    3
                                                                   The VERITAS i CLI utility
                                                                   invokes an installation
                                                                   process that receives its input
                                                                   from a parameter file or
                                                                   command line. It supplements
                                                                                   3
                                                                   the VERITAS i Agent
                                                                   Installer, which is an
                                                                   interactive GUI-driven
                                                                   installation process. It is
                                                                   possible to install servers,
                                                                   Indepth/Oracle, and
                                                                   Indepth/J2EE AppTier
                                                                   Collector agents with the
                                                                                3
                                                                   VERITAS i CLI utility. In
                                                                                              3
                                                                   addition, the VERITAS i CLI
                                                                   utility provides commands for
                                                                   installing patches,
                                                                   maintaining the activity of
                                                                   installed agents, updating
                                                                   their configuration, and
                                                                   uninstalling Indepth/Oracle
                                                                   and Indepth/J2EE AppTiers
                                                                                          3
                                                                   as well as VERITAS i
                                                                   servers.
                                                                   For more information about
                                                                                                 3
                                                                   implementing the VERITAS i
                                                                   CLI in your environment,
                                                                   contact VERITAS Technical
                                                                   Support.

                                                                  Enhancements to the
                                                                   "Support files" mechanism.
                                                                   Additional data is provided for
                                                                   the Indepth/Oracle Collector
                                                                   agents. Temporary folders
                                                                   that are not required are
                                                                   removed.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 i3         IN_INFP_710_003         Obsolete by    1-Feb-    This patch solves the following
                                    patch          2005
                                                             problems:
            (cont.)
                                    IN_INFP_71
                                    0_006                           The reinstallation of
                                                                     Inform/Foresight FocalPoint
                                                                     fails. Agent Installer displays
                                                                     the following error message:
                                                                     Unable to analyze
                                                                     variables

                                                                    Indepth/SAP AppTier
                                                                     Collector agents are not
                                                                     successfully installed and the
                                                                     SLA is not defined when the
                                                                     SAP instance is initially only
                                                                     installed with Interpoint/SAP.

                                                                    Indepth/SAP instances do not
                                                                     have the Availability SLA
                                                                     defined. This patch
                                                                     retroactively sets an SLA for
                                                                     them.

                                                                    Indepth/SAP FocalPoint does
                                                                     not load data into
                                                                     Performance Warehouse if
                                                                     the SAP AppTier already
                                                                     contains other instances and
                                                                     is installed in an environment
                                                                     with SmartLink set to "on."
                                                                     The following error message
                                                                     is written to the Indepth/SAP
                                                                     log file:
                                                                     ID : SEVERE-6510004
                                                                     Msg : Exception while
                                                                     initializing task:
                                                                     User List DataLoader.
                                                                     com.precise.ifweb.infr
                                                                     a.utilities.IfwebRTExc
                                                                     eption
                                                                     Params : User List
                                                                     DataLoader
                                                                     Exception : null
                                                                     Frame :
                                                                     java.lang.NullPointerE
                                                                     xception

                                                                    A monthly planned downtime
                                                                     that does not start on the 1st
                                                                     day of the month is not added
                                                                     correctly.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 i3         IN_INFP_710_003         Obsolete by    1-Feb-          If the user installs a patch,
                                    patch          2005
            (cont.)
                                                                    fails at the first trial, reinstalls
                                    IN_INFP_71                      it, and succeeds, the patch
                                    0_006                           status still indicates 'Errors
                                                                    Reported' although the patch
                                                                    was applied.

                                                                   If a server is identified by its
                                                                    IP address, it appears at the
                                                                    top of the Servers list in
                                                                    AdminPoint and is chosen as
                                                                    the default filter although "All"
                                                                    should always be the default.

                                                                   OS and Web Server
                                                                    instances that are upgraded
                                                                                    3
                                                                    from VERITAS i version 6.x
                                                                    are always connected to the
                                                                    default environment, even if
                                                                    they belong to a different
                                                                    environment.

                                                             Obsolete

                                                             This patch makes patch
                                                             IN_INFP_710_001 obsolete.

                                                             Requirements

                                                                   After applying this patch, you
                                                                    must install patch
                                                                    UI_GUIFP_710_005 on the
                                                                               3
                                                                    VERITAS i FocalPoint
                                                                    server.

                                                                   If you want to use the mass
                                                                    upgrade feature, you also
                                                                    need to install patch
                                                                    IN6xx710U on the server
                                                                                        3
                                                                    where VERITAS i FocalPoint
                                                                    of version 6.x is installed.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 i3         IN_INFP_710_006       Obsolete by    30-Mar-   This patch contains the following
                                  patch          2005
                                                           enhancements:
                                  IN_INFP_71
                                  0_008                           The ability to mass-upgrade
                                                                   the Web and SQL Server
                                                                                            3
                                                                   AppTiers from VERITAS i
                                                                   version 6.x.

                                                                  The ability to install the Siebel
                                                                   AppTier with
                                                                   Interpoint/Oracle.
                                                                   Note: The full support of this
                                                                   option, requires the
                                                                   installation of additional
                                                                   patches. Refer to the
                                                                   Requirements section for
                                                                   more details.

                                                                  Improved performance of the
                                                                              3
                                                                   VERITAS i StartPoint user
                                                                   interface.

                                                                  Additional functionality of the
                                                                              3
                                                                   VERITAS i Command Line
                                                                   Interface (CLI):

                                                                          SQL Server AppTier
                                                                           Collector agent
                                                                           installation.

                                                                          Web AppTier
                                                                           Collector agent
                                                                           installation.

                                                                          The CLI mechanism
                                                                           can also be activated,
                                                                           when the Agent
                                                                           Installer is in the
                                                                           Upgrade mode.
                                                                   For more information about
                                                                                              3
                                                                   implementing the VERITAS i
                                                                   CLI in your environment,
                                                                   contact VERITAS Technical
                                                                   Support.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 i3         IN_INFP_710_006         Obsolete by    30-Mar-   This patch solves the following
                                    patch          2005
                                                             problems:
            (Cont.)
                                    IN_INFP_71
                                    0_008                           The SAP AppTier installation
                                                                     fails when the Agent Installer
                                                                     is started in the Install
                                                                     VERITAS/i3 version v7.1
                                                                     and upgrade components
                                                                     of VERITAS/i3 version 6.x
                                                                     mode. The error message
                                                                     appearing in the Agent
                                                                     Installer and in the VERITAS
                                                                      3
                                                                     i FocalPoint log file is:

                                                                     transient registry get
                                                                     request failed path
                                                                     transient/products/i3f
                                                                     p/install/properties/i
                                                                     nstall-action code
                                                                     11183

                                                                    The upgrade of a J2EE
                                                                     AppTier fails when
                                                                     Indepth/J2EE is integrated
                                                                     with Insight, and
                                                                     Indepth/J2EE FocalPoint of
                                                                     version 6.x is installed on a
                                                                     different server than the one
                                                                     of version 7.1.1. The following
                                                                     error message appears in the
                                                                     Agent Installer:

                                                                     error line missing in
                                                                     line stdout (got eof).

                                                                     And the following error
                                                                     message appears in the
                                                                     Insight FocalPoint log:

                                                                     ID : SEVERE-3010371
                                                                     Msg : UpgradeRegistry
                                                                     - Unable to get the
                                                                     registry path
                                                                     /registry/products/ins
                                                                     ight/hosts/[host] of
                                                                     I3
                                                                     version 6 server.
                                                                     Upgrade registry
                                                                     failed.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 i3         IN_INFP_710_006         Obsolete by    30-Mar-         When uninstalling the last
                                    patch          2005
            (Cont.)
                                                                    instance of an AppTier, and
                                    IN_INFP_71                      then trying to install a new
                                    0_008                           instance of that AppTier, the
                                                                    installation process fails. An
                                                                                         3
                                                                    internal VERITAS i error
                                                                    appears in the Agent Installer.

                                                                   When installing a Web
                                                                    AppTier for an iPlanet or a
                                                                    WebLogic Web server, and
                                                                    the path to the Web server
                                                                    installation directory contains
                                                                    a folder, of which the name
                                                                    starts with a number, for
                                                                    example:
                                                                    /disk2/iPlanet/6e41/Fa
                                                                    stTrack_E4.1, the Agent
                                                                    Installer fails to detect any of
                                                                    the Web server instances and
                                                                    the displayed Instance name
                                                                    field will remain empty.

                                                             Important warning:

                                                                   When installing the patch on
                                                                    the target server, the
                                                                    following message can be
                                                                    displayed:
                                                             The file psin_cli_<os>.zip
                                                             already exists on the remote
                                                             server <server name> and its
                                                             size is different (Target
                                                             file size on the remote
                                                             server is: <size> Source
                                                             file size is: <size>). Would
                                                             you like to replace the
                                                             existing file with the
                                                             updated one?
                                                             you should choose the option Yes to
                                                             All.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 i3         IN_INFP_710_006         Obsolete by    30-Mar-   Requirements:
                                    patch          2005
            (Cont.)
                                    IN_INFP_71                      After applying this patch you
                                    0_008                            must also install the latest
                                                                                             3
                                                                     cumulative VERITAS i user
                                                                     interface patch on the
                                                                                 3
                                                                     VERITAS i FocalPoint
                                                                     server. At the release date of
                                                                     this patch that is the
                                                                     UI_GUIFP_710_008 patch.

                                                                    In order to use the mass
                                                                     upgrade feature after the
                                                                     installation of this patch,
                                                                     please install patch
                                                                     IN6xx710U on the VERITAS
                                                                      3
                                                                     i FocalPoint server of version
                                                                     6.x.

                                                                    In order to install the Siebel
                                                                     AppTier with Interpoint/Oracle
                                                                     after the installation of this
                                                                     patch, you must also install
                                                                     the following patches on the
                                                                     server, on which the
                                                                     Indepth/Oracle Collector
                                                                     agents are installed:

                                                                            The latest cumulative
                                                                                        3
                                                                             VERITAS i Listener
                                                                             agent patch. At the
                                                                             release date of this
                                                                             patch that is the
                                                                             IN_INBA_710_007
                                                                             patch.

                                                                            The Indepth/Oracle
                                                                             OR_FPAG_710_007
                                                                             and
                                                                             OR_FPAG_710_008
                                                                             patches.

                                                             Obsolete:

                                                             This patch is cumulative, and includes
                                                             all updates and fixes from the patches
                                                             IN_INFP_710_001 and
                                                             IN_INFP_710_003, making those
                                                             patches obsolete.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 i3         IN_INBA_710_007       Obsolete by    30-Mar-                                        3
                                                           This patch enhances the VERITAS i
                                  patch          2005
                                  IN_INBA_71
                                                           Listener agent, in order to support the
                                  0_009                    installation of the Siebel AppTier with
                                                                                                3
                                  which was                Interpoint/Oracle on the VERITAS i
                                  published as             Server. Install the patch on the server,
                                  part of
                                                           on which the Indepth/Oracle Collector
                                  Bundle Patch
                                  BU_I3_710_               agents are installed.
                                  001
                                                           Requirements:

                                                           In order to install the Siebel AppTier
                                                           with Interpoint/Oracle, you must also
                                                           install the following patches:
                                                                              3
                                                           On the VERITAS i FocalPoint
                                                           server:

                                                                  The latest cumulative
                                                                               3
                                                                   VERITAS i user interface
                                                                   patch. At the release date of
                                                                   this patch, that is the
                                                                   UI_GUIFP_710_008 patch.

                                                                  The latest cumulative
                                                                               3
                                                                   VERITAS i infrastructure
                                                                   patch. At the release date of
                                                                   this patch, that is the
                                                                   IN_INFP_710_006 patch.

                                                           On the server, on which the
                                                           Indepth/Oracle Collector agents are
                                                           installed:

                                                                  The Indepth/Oracle
                                                                   OR_FPAG_710_007 and
                                                                   OR_FPAG_710_008 patches.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                  Release
  Product           Patch ID        Status                               Description
                                                   Date

 i3         IN_INFP_710_008       Published       20-Jun-   This patch contains the following
                                                  2005
                                                            enhancements:

                                                                   Modification of the VERITAS
                                                                     3
                                                                    i patch installation
                                                                    mechanism to support the
                                                                    installation of a Bundle Patch
                                                                    release. In order for this
                                                                    functionality to work, you are
                                                                    also required to install a
                                                                                3
                                                                    VERITAS i User Interface
                                                                    patch. For more details, refer
                                                                    to the Requirements section.

                                                                   Improvement of the VERITAS
                                                                     3
                                                                    i StartPoint and AdminPoint
                                                                    UI performance.

                                                                   Support for the usage of
                                                                    spaces in parameters,
                                                                                             3 tm
                                                                    entered in the VERITAS i
                                                                    7.1.x Command Line
                                                                    Interface (CLI) utility.

                                                                   Modification of the Web
                                                                    AppTier installation module.
                                                                    Instances that start with a
                                                                    digit or contain spaces in their
                                                                    name can be added.

                                                                   Support files will now contain
                                                                    two additional files: one file
                                                                    that contains a list of the
                                                                    installed patches and another
                                                                    file that contains a list of files,
                                                                    sorted by their modification
                                                                    date.

                                                                   Support for installing the
                                                                    Performance Warehouse
                                                                    database on Oracle version
                                                                    9.2.0.6, 10.1.0.2 and
                                                                    10.1.0.3. The release of this
                                                                    enhancement, as part of this
                                                                    patch, makes the previously
                                                                    released Performance
                                                                    Warehouse patch obsolete.
                                                                    For more details, refer to the
                                                                    Obsolete section.




                                              3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID        Status                             Description
                                                     Date

 i3         IN_INFP_710_008         Published       20-Jun-         Note
                                                    2005
            (cont.)
                                                                     In case you intend to install
                                                                     the Performance Warehouse
                                                                     database on one of these
                                                                     versions, this patch must be
                                                                                               3
                                                                     applied to the VERITAS i
                                                                     FocalPoint server, during the
                                                                                 3
                                                                     VERITAS i Framework
                                                                     installation. Perform the
                                                                     following steps:

                                                                         1. For the support of the
                                                                            Oracle 10g versions
                                                                            10.1.0.2 and
                                                                            10.1.0.3:

                                                                                 a. Set the
                                                                                    following
                                                                                    event in the
                                                                                    init.ora
                                                                                    file of the
                                                                                    Performance
                                                                                    Warehouse
                                                                                    database:
                                                              14525 trace name context
                                                              forever, level 1

                                                                                 b. Restart the
                                                                                    Performance
                                                                                    Warehouse
                                                                                    database to
                                                                                    ensure that
                                                                                    the event is
                                                                                    set.

                                                                         4. Complete the steps
                                                                            for the installation of
                                                                                        3
                                                                            VERITAS i
                                                                            FocalPoint, but do
                                                                            not install
                                                                            Performance
                                                                            Warehouse.

                                                                         5. Click Finish and
                                                                            close the browser
                                                                            windows after
                                                                                                 3
                                                                            installing VERITAS i
                                                                            FocalPoint.




                                                3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID        Status                               Description
                                                     Date

 i3         IN_INFP_710_008         Published       20-Jun-               3. Open AdminPoint in
                                                    2005                     a new browser
            (cont.)                                                          window and install
                                                                             this patch.

                                                                          4. After applying the
                                                                             patch, open the
                                                                             Agent Installer from
                                                                             AdminPoint and
                                                                             continue with the
                                                                             installation steps for
                                                                             the Performance
                                                                             Warehouse
                                                                             Framework.

                                                              The patch solves the following
                                                              problems:

                                                                     The upgrade of Indepth/Web
                                                                                                      3
                                                                      FocalPoint from a VERITAS i
                                                                      Version 6.x installation fails.
                                                                      The following error message
                                                                      is displayed:

                                                                      ID : WARNING-1000158
                                                                      Msg : Installer log
                                                                      message : The
                                                                      AgentInstaller had
                                                                      errors during the
                                                                      installation. More
                                                                      information can be
                                                                      found in the .trc
                                                                      files.

                                                                     Failures occur during the
                                                                      Copy files stage of the
                                                                                   3 tm
                                                                      VERITAS i         7.1.x
                                                                      Command Line Interface
                                                                      (CLI) utility - during the patch
                                                                      installation, there is no failure
                                                                      indication displayed on the
                                                                      AdminPoint patches screen.

                                                                     Installation of Inform
                                                                      Foresight FocalPoint on a
                                                                      server other than the
                                                                      Performance Warehouse
                                                                      FocalPoint server, incorrectly
                                                                      adds an Inform Alerts
                                                                      InformPoint on the server with
                                                                      the Inform Foresight
                                                                      FocalPoint and not on the
                                                                      Performance Warehouse
                                                                      FocalPoint server.

                                                3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID        Status                              Description
                                                     Date

 i3         IN_INFP_710_008         Published       20-Jun-         When a FocalPoint is
                                                    2005
                                                                     uninstalled and then
            (cont.)
                                                                     reinstalled, its collector data
                                                                     is not saved to the
                                                                     Performance Warehouse
                                                                     database, because the link to
                                                                     the Performance Warehouse
                                                                     FocalPoint is not created.

                                                                    Removing the integration
                                                                     between Insight and
                                                                     Indepth/J2EE add-ons is not
                                                                     working properly -
                                                                     Indepth/J2EE agents are not
                                                                     stopped after the removal of
                                                                     the integration with Insight.

                                                                    Core dump issues and other
                                                                     JRE related issues are solved
                                                                     by deploying new JREs for
                                                                     the following platforms: Linux,
                                                                     Windows, and AIX.

                                                                     Note

                                                              These JREs are dedicated and only
                                                                                 3
                                                              used by VERITAS i components.
                                                              They only replace the JREs on the
                                                                        3
                                                              VERITAS i FocalPoint server.

                                                                    During an upgrade of
                                                                                 3
                                                                     VERITAS i FocalPoint, errors
                                                                     are experienced. The
                                                                     following is example of an
                                                                     error message written to the
                                                                     infra.i3fp.log file:

                                                                     ID : CONFIG-1001100
                                                                     Msg : Error in Sync.
                                                                     Sync details:

                                                                    Files that are collected for the
                                                                                 3
                                                                     VERITAS i Events
                                                                     mechanism are consuming
                                                                     large amounts of disk space
                                                                                         3
                                                                     on the VERITAS i FocalPoint
                                                                     server under the folder:

                                                                     Windows
                                                                     <i3
                                                                     root>\products\i3fp\ev
                                                                     ent\load



                                                3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID        Status                              Description
                                                     Date

 i3         IN_INFP_710_008         Published       20-Jun-           UNIX
                                                    2005              <i3
            (cont.)
                                                                      root>/products/i3fp/ev
                                                                      ent/load

                                                              Notes

                                                                     During the installation of the
                                                                      patch, the following message
                                                                      may appear:

                                                                      The file <file name>
                                                                      already exists on the
                                                                      remote server (<server
                                                                      name>) and its size is
                                                                      different (Target file
                                                                      size on remote server
                                                                      is: <file size> Source
                                                                      file size is: <file
                                                                      size>).
                                                                      Would you like to
                                                                      replace the existing
                                                                      file with the updated
                                                                      one?

                                                                      In this case, press Yes to All.

                                                                     After the installation of this
                                                                      patch, post-installation action
                                                                      items will appear dynamically,
                                                                      according to the operating
                                                                      system the patch was
                                                                      installed on:

                                                                             For Windows, AIX,
                                                                              and Linux operating
                                                                              systems you will
                                                                              need to run a script
                                                                              named
                                                                              psin_update_JRE.
                                                                              This script will update
                                                                              the new JRE and
                                                                              restart the VERITAS
                                                                               3
                                                                              i FocalPoint server.

                                                                             For HP-UX, SunOS,
                                                                              and OSF1 operating
                                                                              systems you will
                                                                              need to run a script
                                                                              named
                                                                              IN_INFP_710_008_
                                                                              01. This script will
                                                                              restart the VERITAS
                                                                               3
                                                                              i FocalPoint server.

                                                3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID        Status                               Description
                                                     Date

 i3         IN_INFP_710_008         Published       20-Jun-   Requirements
                                                    2005
            (cont.)
                                                              This patch requires the installation of
                                                              the UI_GUIFP_710_011 patch. Install
                                                                              3
                                                              the VERITAS i User Interface patch
                                                              before or after installing this patch.

                                                              Obsolete

                                                              This patch is cumulative, and includes
                                                              all enhancements and fixes that were
                                                              previously released in patch
                                                              IN_INFP_710_006, making that
                                                              patch obsolete. Due to the fact that
                                                              this patch includes support for
                                                              installing the Performance
                                                              Warehouse database on Oracle
                                                              version 9.2.0.6, 10.1.0.2 and 10.1.0.3,
                                                              it also makes the Performance
                                                              Warehouse patch
                                                              PW_PWFP_710_002 obsolete.




                                                3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 i3         IN_INBA_710_009       Obsolete by    20-Jun-   This patch solves the following
                                  patch          2005
                                  IN_FPAGS_
                                                           problems:
                                  710_010
                                  released as                     Security problem - The
                                                                               3
                                  part of                          VERITAS i Listener agent
                                  Bundle Patch                     now disables the usage of an
                                  BU_I3_710_
                                  002                              external interface to
                                                                   manipulate files on the
                                                                   server.

                                                                  Core dump issues and other
                                                                   JRE related issues - New
                                                                   JREs are now deployed for
                                                                   the following platforms: Linux,
                                                                   Windows, and AIX.

                                                           Note

                                                           These JREs are dedicated and only
                                                                                  3
                                                           used by the VERITAS i components.
                                                           They only replace the JREs on the
                                                                     3
                                                           VERITAS i server.

                                                                  Insight/SmartLink file locks -
                                                                   Files required for the
                                                                   Insight/SmartLink mechanism
                                                                   were locked and could not be
                                                                   transferred to the Insight
                                                                   FocalPoint, causing a lack of
                                                                   information in the
                                                                   Insight/SmartLink user
                                                                   interface for J2EE AppTiers
                                                                   and other technologies, which
                                                                   were monitored on the server
                                                                   with the J2EE AppTier.

                                                               
                                                                                3
                                                                   If VERITAS i uses the AES
                                                                   communication encryption:

                                                                          The following error
                                                                           occurs during the
                                                                           installation of a UNIX
                                                                           server:
                                                                           Unable to get
                                                                           server
                                                                           information from
                                                                           the remote
                                                                           server.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 i3         IN_INBA_710_009         Obsolete by    20-Jun-                  The following error
                                    patch          2005
                                    IN_FPAGS_
                                                                             occurs during the
            (cont.)
                                    710_010                                  reinstallation of a
                                    released as                              server:
                                    part of                                  The VERITAS/i3
                                    Bundle Patch                             Listener is not
                                    BU_I3_710_
                                    002                                      running.

                                                             Obsolete

                                                             This patch is cumulative, and includes
                                                             all updates and fixes from patch
                                                             IN_INFP_710_007, therefore
                                                             making that patch obsolete.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 i3         IN_FPAGS_710_010      Published(b)   22-Jul-   This patch contains the following
                                  Released as    2005
                                  part of
                                                           enhancements:
                                  Bundle Patch
                                  BU_I3_710_                      Performance improvements
                                  002                              in the installation of the Other
                                                                   AppTier.

                                                                  Performance improvements
                                                                   in the user interface of the
                                                                              3
                                                                   VERITAS i AdminPoint
                                                                   Events View and the
                                                                   Environment Settings
                                                                   window.

                                                                  Adding a new server will
                                                                   automatically apply all
                                                                   enhancements and fixes to
                                                                                  3
                                                                   the VERITAS i Listener
                                                                   agent that were released as
                                                                   part of this Bundle patch.

                                                                  The Server Name column
                                                                   was added to the Availability
                                                                   Goals Table of the
                                                                   Availability tab in the SLA
                                                                   settings screen.

                                                                  Improvements to the clarity of
                                                                   the error messages that can
                                                                   appear during a patch
                                                                   installation, performed with
                                                                                   3
                                                                   the VERITAS i Command
                                                                   Line Interface (CLI) utility.

                                                                  Additional functionality of the
                                                                              3
                                                                   VERITAS i Command Line
                                                                   Interface (CLI) utility:

                                                                  An Oracle AppTier that was
                                                                   installed using the CLI utility
                                                                   can be edited and modified
                                                                   using the Agent Installer.

                                                           For more information about
                                                                                          3
                                                           implementing the VERITAS i CLI
                                                           utility in your environment, contact
                                                           VERITAS Technical Support.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                               Description
                                                    Date

 i3         IN_FPAGS_710_010        Published(b)   20-Jul-   The patch solves the following
                                    Released as    2005
                                    part of
                                                             problems:
            (cont.)
                                    Bundle Patch
                                    BU_I3_710_                       Installation of an SQL Server
                                    002                               AppTier will get stuck when
                                                                      choosing the Install the
                                                                      COM+ extension option and
                                                                      the name of one of the
                                                                      available servers contains a
                                                                      space. The following error
                                                                      message will also be entered
                                                                      in the infra.i3fp.trc file:

                                                             The name <the server name
                                                             with spaces> is not legal
                                                             for JDOM/XML elements: XML
                                                             names cannot contain the " "
                                                             character.

                                                                     The loading of performance
                                                                      data hangs when the files to
                                                                      be loaded contain spaces in
                                                                      their names.

                                                                     The Performance Warehouse
                                                                      Summary process halts, and
                                                                      the summary process never
                                                                      finishes when the server with
                                                                      the Performance Warehouse
                                                                      FocalPoint is on a GMT + not
                                                                      a full hour time zone (for
                                                                      example the New Delhi time
                                                                      zone).

                                                             Note

                                                             After the installation of this patch, the
                                                             post installation action items will ask
                                                             you to activate a script named
                                                             "IN_FPAGS_710_010_01".
                                                             Activation of this script will stop and
                                                                                            3
                                                             then restart the VERITAS i Listener
                                                                            3
                                                             or VERITAS i FocalPoint agents.

                                                             Obsolete

                                                             This patch is cumulative, and includes
                                                             all updates and fixes that were
                                                                                                  3
                                                             previously released in the VERITAS i
                                                             Infrastructure patches (except for the
                                                             ones released in patch
                                                             IN_INFP_710_008), making those
                                                             patches obsolete.


                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 PW         PW_PWFP_710_001       Obsolete by    1-Dec-    This patch solves the following
                                  patch          2004
                                                           problems:
                                  PW_PWFP_
                                  710_004                         The Warehouse Status in the
                                                                   AdminPoint shows irrelevant
                                                                   load processes for the
                                                                   processes of 'i3 common'.

                                                                  On MS-SQL based
                                                                   installations, due to a problem
                                                                   in the purge process the
                                                                   warehouse status shows
                                                                   incorrect values in the 'First
                                                                   Loaded Data' column.

                                                                  Planned down time definition
                                                                   expands for an extra slice, for
                                                                   example if you define
                                                                   Planned Down Time from
                                                                   12:00 to 13:00 The instance/s
                                                                   will be considered down from
                                                                   12:00 to 13:15 in the PW and
                                                                   also in the availability graphs
                                                                   of the relevant products.

                                                                  On UNIX based installations,
                                                                   Fixed a problem in restarting
                                                                   the PW when a deadlock in
                                                                   the PW JVM was discovered.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                  Release
  Product          Patch ID         Status                               Description
                                                   Date

 PW         PW_PWFP_710_002       Published       06-Feb-   This patch adds support for installing
                                                  2005
                                                            Performance Warehouse on Oracle
                                                            version 9.2.0.6, 10.1.0.2 and 10.1.0.3.

                                                            This patch should be applied to the
                                                                        3
                                                            VERITAS i FocalPoint server during
                                                                            3
                                                            the VERITAS i Framework
                                                            installation as follows:

                                                                   Complete the steps for the
                                                                                                 3
                                                                    installation of the VERITAS i
                                                                    FocalPoint, but do not install
                                                                    Performance Warehouse.

                                                                   Click Finish and close the
                                                                    browser windows after
                                                                                        3
                                                                    installing VERITAS i
                                                                    FocalPoint.

                                                                   Open AdminPoint in a new
                                                                    browser window and install
                                                                    this patch.

                                                                   After applying this patch,
                                                                    open the Agent Installer from
                                                                    AdminPoint and continue with
                                                                    the installation steps for the
                                                                    Performance Warehouse
                                                                    Framework.




                                              3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 PW         PW_PWFP_710_003       Rejected and   15-Feb-   This patch adds the following
                                  replaced by    2005
                                  patch
                                                           functionality:

                                  PW_PWFP_                        Support for adding an
                                  710_004                          external interface to
                                                                   Performance Warehouse that
                                                                   enables it to store and
                                                                   retrieve additional application
                                                                   data. This can then be
                                                                   correlated with all the
                                                                   performance data stored by
                                                                                   3
                                                                   the VERITAS i products in
                                                                   the Performance Warehouse
                                                                   database.
                                                                   For more information about
                                                                   using this functionality in your
                                                                   environment, contact
                                                                   VERITAS Technical Support.

                                                           This patch solves the following
                                                           problem:

                                                                  When the warehouse
                                                                   database size in an Oracle
                                                                   based Performance
                                                                   Warehouse reaches 32GB,
                                                                   the status of the Performance
                                                                   Warehouse FocalPoint agent
                                                                   changes from running to fault,
                                                                   due to a miscalculation of the
                                                                   available schema disk space.

                                                           Obsolete

                                                           This patch contains all fixes released
                                                           in patch PW_PWFP_710_001 making
                                                           that patch obsolete.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 PW         PW_PWFP_710_004       Obsolete by    28-Feb-   This patch adds the following
                                  patch          2005
                                                           functionality:
                                  PW_PWFP_
                                  710_005                         Support for adding an
                                  which was                        external interface to
                                  published as                     Performance Warehouse that
                                  part of
                                  Bundle Patch                     enables it to store and
                                  BU_I3_710_                       retrieve additional application
                                  001                              data. This can then be
                                                                   correlated with all the
                                                                   performance data stored by
                                                                                   3
                                                                   the VERITAS i products in
                                                                   the Performance Warehouse
                                                                   database.
                                                                   For more information about
                                                                   using this functionality in your
                                                                   environment, contact
                                                                   VERITAS Technical Support.

                                                           This patch solves the following
                                                           problem:

                                                                  When the warehouse
                                                                   database size in an Oracle
                                                                   based Performance
                                                                   Warehouse reaches 32GB,
                                                                   the status of the Performance
                                                                   Warehouse FocalPoint agent
                                                                   changes from running to fault,
                                                                   due to a miscalculation of the
                                                                   available schema disk space.

                                                           Obsolete

                                                           This patch contains all fixes released
                                                           in patch PW_PWFP_710_001 making
                                                           that patch obsolete.

                                                           Warning

                                                           Do not install patch
                                                           PW_PWFP_710_003. Due to a
                                                           problem, we are replacing it with this
                                                           patch. In case you did install patch
                                                           PW_PWFP_710_003, you must install
                                                           patch PW_PWFP_710_004. This patch
                                                           contains all enhancements and fixes
                                                           as were released in patch
                                                           PW_PWFP_710_003.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 PW         PW_PWFP_710_005       Obsolete by    20-Jun-   This patch is a cumulative patch that
                                  patch          2005
                                  PW_PWFP_
                                                           contains fixes for the following
                                  710_006                  problems:
                                  released as
                                  part of                         Maintenance processes:
                                  Bundle Patch
                                  BU_I3_710_
                                  002
                                                                          Errors that occur
                                                                           during the calculate
                                                                           statistics stage of the
                                                                           Performance
                                                                           Warehouse
                                                                           Maintenance Process
                                                                           (weekly) are only
                                                                           written to the log files
                                                                           and not displayed on
                                                                           the screen, nor
                                                                           added to the Run
                                                                           History details.

                                                                          The (weekly) process
                                                                           fails with a time out
                                                                           when cleaning the
                                                                           normalization tables.
                                                                           The user gets a
                                                                           message from the
                                                                           GUI that the process
                                                                           has failed. The
                                                                           message in the log
                                                                           file is (in an Oracle
                                                                           installation):

                                                                           ID : SEVERE-
                                                                           2000312
                                                                           Msg: "unable to
                                                                           calculate
                                                                           statistics for:
                                                                           table",
                                                                           Exception :
                                                                           "ORA-01555:
                                                                           snapshot too
                                                                           old"




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                        Description
                                                    Date

 PW         PW_PWFP_710_005         Obsolete by    20-Jun-             The (weekly) process
                                    patch          2005
                                    PW_PWFP_
                                                                        fails with a time out
            (cont.)
                                    710_006                             when cleaning the
                                    released as                         internal Performance
                                    part of                             Warehouse tables.
                                    Bundle Patch
                                                                        The user gets a
                                    BU_I3_710_
                                    002                                 message from the
                                                                        GUI that the process
                                                                        has failed. The
                                                                        message in the log
                                                                        file is:

                                                                        ID : SEVERE-
                                                                        2050097
                                                                        Msg: "Failed to
                                                                        execute SQL
                                                                        command. in
                                                                        query id : 6 for
                                                                        sql text :
                                                                        delete from
                                                                        PW_PWJG_JOB_GROU
                                                                        P where
                                                                        PWJG_BEGIN_TIMES
                                                                        TAMP < (-?) +
                                                                        sysdate and
                                                                        PWJG_ID not in
                                                                        (select
                                                                        PWSE_JOB_ID from
                                                                        PS_PWSE_SCHEDULE
                                                                        D_EVENTS)",
                                                                        Exception :
                                                                        "ORA-01013: user
                                                                        requested cancel
                                                                        of current
                                                                        operation"




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 PW         PW_PWFP_710_005         Obsolete by    20-Jun-         Load Performance Data
                                    patch          2005
                                    PW_PWFP_
                                                                    process:
            (cont.)
                                    710_006
                                    released as                           The Load
                                    part of                                Performance Data
                                    Bundle Patch                           process fails for any
                                    BU_I3_710_
                                    002                                    of the AppTiers,
                                                                           displaying the
                                                                           following error
                                                                           message:

                                                                           ID : SEVERE-
                                                                           2050067
                                                                           Msg: "Unable to
                                                                           load data to
                                                                           Performance
                                                                           Warehouse",
                                                                           Exception :
                                                                           "java.lang.Strin
                                                                           gIndexOutOfBound
                                                                           sException:
                                                                           String index out
                                                                           of range"

                                                                   Purge Data process:

                                                                          The process hangs in
                                                                           an MSSQL-based
                                                                           Performance
                                                                           Warehouse
                                                                           installation, after all
                                                                           data is purged and no
                                                                           new data is loaded
                                                                           (due to the lack of
                                                                           activity in the
                                                                           monitored instance).

                                                                   Calculate Baselines process:

                                                                          If a database login, in
                                                                           an MSSQL-based
                                                                           Performance
                                                                           Warehouse
                                                                           installation, is
                                                                           configured with
                                                                           German as its
                                                                           language, the
                                                                           produced Baseline
                                                                           values are shifted
                                                                           one day (for example
                                                                           the Baseline value for
                                                                           Monday is shown as
                                                                           the one for Tuesday).


                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 PW         PW_PWFP_710_005         Obsolete by    20-Jun-         FocalPoint agent:
                                    patch          2005
            (cont.)                 PW_PWFP_
                                    710_006                               Performance
                                    released as                            Warehouse
                                    part of                                FocalPoint fails to
                                    Bundle Patch                           start some of the
                                    BU_I3_710_
                                    002                                    Performance
                                                                           Warehouse
                                                                           processes during the
                                                                           database
                                                                           initialization. The
                                                                           processes that are
                                                                           not started, have no
                                                                           value in the "Next
                                                                           Scheduled Run"
                                                                           field in the
                                                                           Performance
                                                                           Warehouse
                                                                           Processes
                                                                           AdminPoint screen.

                                                                          Verification of the
                                                                           Performance
                                                                           Warehouse
                                                                           FocalPoint agent
                                                                           takes a long period of
                                                                           time or times out. The
                                                                           user gets a message
                                                                           from the GUI that the
                                                                           process has failed.
                                                                           The message in the
                                                                           infra log file is:




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                        Description
                                                    Date

 PW         PW_PWFP_710_005         Obsolete by    20-Jun-            ID : SEVERE-
                                    patch          2005               1001600
            (cont.)                 PW_PWFP_
                                    710_006                           Msg: "Agent
                                    released as                       Performance
                                    part of                           Warehouse
                                    Bundle Patch                      FocalPoint on
                                    BU_I3_710_
                                    002
                                                                      server X
                                                                      returned invalid
                                                                      response for
                                                                      action verify.
                                                                      Make sure the
                                                                      agent is
                                                                      installed and
                                                                      configurated
                                                                      well.",
                                                                      Exception :
                                                                      "empty response
                                                                      from agent on
                                                                      ivp request:
                                                                      ((psin_agent_man
                                                                      ager:result from
                                                                      agent is:) recv
                                                                      failed. iRc: -1,
                                                                      timeout
                                                                      was(900000)
                                                                      error 10060:A
                                                                      connection
                                                                      attempt failed
                                                                      because the
                                                                      connected party
                                                                      did not properly
                                                                      respond after a
                                                                      period of time,
                                                                      or established
                                                                      connection
                                                                      failed because
                                                                      connected host
                                                                      has failed to
                                                                      respond."




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 PW         PW_PWFP_710_005         Obsolete by    20-Jun-                  Verification of the
                                    patch          2005
                                    PW_PWFP_
                                                                             Performance
            (cont.)
                                    710_006                                  Warehouse
                                    released as                              FocalPoint agent fails
                                    part of                                  in an Oracle-based
                                    Bundle Patch
                                                                             Performance
                                    BU_I3_710_
                                    002                                      Warehouse
                                                                             database, in case the
                                                                             maximum size setting
                                                                             of the database
                                                                             datafile is smaller
                                                                             than its actual size.
                                                                             The verification
                                                                             provides a warning
                                                                             message that the
                                                                             database has
                                                                             reached its size limit.

                                                                    Move and Rename
                                                                     procedure:

                                                                            Moving an MSSQL-
                                                                             based Performance
                                                                             Warehouse database
                                                                             (using the VERITAS
                                                                              3
                                                                             i Move and Rename
                                                                             procedure) corrupts
                                                                             the connection to the
                                                                             database.

                                                             Obsolete

                                                             This patch is cumulative and includes
                                                             all fixes that were previously released
                                                             in patch PW_PWFP_710_004 (and all
                                                             of its predecessors), therefore making
                                                             that patch obsolete.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 PW         PW_PWFP_710_006       Published(b)   22-Jul-   This patch contains the following
                                  Released as    2005
                                  part of
                                                           enhancement:
                                  Bundle Patch
                                  BU_I3_710_                      Changes in the Performance
                                  002                              Warehouse schema in order
                                                                   to support Citrix monitoring.
                                                                   For more information, contact
                                                                   VERITAS Technical Support.

                                                           Obsolete

                                                           This patch is cumulative, and includes
                                                           all fixes that were previously released
                                                           in patch PW_PWFP_710_005 (and all
                                                           of its predecessors), therefore making
                                                           that patch obsolete




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 GUI        UI_GUIFP_710_001      Obsolete by    01-Nov-
                                  patch          2004
                                                           This patch contains fixes for the
                                                           following problems:
                                  UI_GUIFP_7
                                  10_002                          Problems related to all
                                                                   products

                                                                       o   When a specific time
                                                                           frame was chosen
                                                                           (not in the form of
                                                                           "Last N time units") or
                                                                           when zooming into a
                                                                           specific time
                                                                           frame, there were
                                                                           times when
                                                                           only partial data was
                                                                           displayed or when no
                                                                           data was displayed.

                                                                       o   A pop-up error
                                                                           message notifying
                                                                           that "A Runtime
                                                                           Error has occurred"
                                                                           was displayed when
                                                                           selecting the
                                                                           Associate
                                                                           with dialog box and
                                                                           selecting a field
                                                                           whose type was
                                                                           'number'.

                                                                       o   Incorrect display of
                                                                           strings in the User
                                                                           Interface. Instead of
                                                                           displaying the correct
                                                                           data an "RNF" string
                                                                           was displayed.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 GUI        UI_GUIFP_710_001        Obsolete by    01-Nov-         Problems related to
                                    patch          2004
            (cont.)
                                                                    Inform/Alerts
                                    UI_GUIFP_7
                                    10_002                             o   Failure to launch
                                                                           Indepth/Web for
                                                                           "Top
                                                                           Activities" metric.
                                                                           Launching was
                                                                           failing, providing
                                                                           an error pop-up
                                                                           window with the
                                                                           following error
                                                                           message
                                                                           "clsInit::getAllIncludes
                                                                           : Failed trying to load
                                                                           include..." followed
                                                                           by another error pop-
                                                                           up window with the
                                                                           following error
                                                                           message
                                                                           "clsInit::BuildRequest
                                                                           : Failed trying to load
                                                                           api..."

                                                                       o   Failure to launch
                                                                           Indepth/SQL for
                                                                           "Top Activities"
                                                                           metric. Launching
                                                                           was failing, providing
                                                                           an error pop-up
                                                                           window with the
                                                                           following error
                                                                           message "A Runtime
                                                                           error has occurred".

                                                                       o   An unnecessary error
                                                                           message was
                                                                           generated, asking the
                                                                           user to fill in a
                                                                           field's value, when th
                                                                           e "Cancel" button
                                                                           was clicked in the
                                                                           "Settings" screen.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 GUI        UI_GUIFP_710_001        Obsolete by    01-Nov-         Problems related to
                                    patch          2004
            (cont.)
                                                                    Inform/Foresight
                                    UI_GUIFP_7
                                    10_002                             o   The User Interface
                                                                           hung when the "OK"
                                                                           button was
                                                                           clicked, while
                                                                           viewing the
                                                                           Description tab in the
                                                                           Report Property
                                                                           dialog box.

                                                                       o   The Reports view
                                                                           produced a Java
                                                                           Script error message
                                                                           and the User
                                                                           Interface would hang.
                                                                           This problem
                                                                           was experienced in
                                                                           environments in
                                                                           which MSXML 3
                                                                           Service Pack 5 was
                                                                           installed.

                                                                   Problems related to Insight

                                                                       o   Launching from
                                                                           Inform/Foresight to
                                                                           Insight did
                                                                           not focus on
                                                                           the correct OS
                                                                           Command.

                                                                       o   In
                                                                           the Insight/SmartLin
                                                                           k Flow workspace,
                                                                           the colors displayed
                                                                           in the "AppTiers
                                                                           Times (Summed)"
                                                                           column of the
                                                                           "Transaction Table"
                                                                           did not match to the
                                                                           colors of the icons
                                                                           displayed in the
                                                                           "Transaction Tree".




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 GUI        UI_GUIFP_710_001        Obsolete by    01-Nov-             o   When
                                    patch          2004
                                                                           launching Indepth/S
            (cont.)
                                    UI_GUIFP_7                             AP from Insight,
                                    10_002                                 the "Association area
                                                                           " in the Activity
                                                                           workspace displayed
                                                                           an "Internal retrieval
                                                                           error" instead of the
                                                                           relevant data.

                                                                   Problems related to
                                                                    Indepth/SAP

                                                                       o   When launching
                                                                           Indepth/SAP from
                                                                           another product the
                                                                           ascending sort of the
                                                                           data was not
                                                                           retained.

                                                                   Problems related to
                                                                    Indepth/Web

                                                                       o   The field titled "Page
                                                                           Service+Network
                                                                           Time (Avg) NIU"
                                                                           was wrongly displaye
                                                                           d as an option in
                                                                           the sort combo of the
                                                                           Activity workspace.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 GUI        UI_GUIFP_710_001        Obsolete by    01-Nov-         Problems related to VERITAS
                                    patch          2004              3
            (cont.)
                                                                    i AdminPoint
                                    UI_GUIFP_7
                                    10_002                             o   When editing
                                                                           values that are not
                                                                           related to purging, an
                                                                           unnecessary
                                                                           notification message
                                                                           regarding purge data
                                                                           in Warehouse
                                                                           Processes
                                                                           was displayed.

                                                                       o   Dialog boxes
                                                                           enabling the editing
                                                                           of Warehouse
                                                                           Process
                                                                           parameters showed
                                                                           only partial sections
                                                                           of the text.

                                                                   Problems related to VERITAS
                                                                     3
                                                                    i Agent Installer

                                                                       o   Installation for
                                                                           Tuxedo 6.5 64 bit
                                                                           was not supported.
                                                                           (Note: In order to
                                                                           complete the support
                                                                           for this Tuxedo
                                                                           version, patch IS-
                                                                           MUAGS-710-002
                                                                           must be installed on
                                                                           the servers that are
                                                                           installed with this
                                                                           Tuxedo version).

                                                                       o   A Java Script
                                                                           error message was
                                                                           displayed when
                                                                           installing an
                                                                           Indepth/SAP AppTie
                                                                           r in an upgrade
                                                                           mode, and when
                                                                           Inform/Alerts had
                                                                           been previously
                                                                           installed.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 GUI        UI_GUIFP_710_002      Obsolete by    16-Dec-   This patch solves the following
                                  patch          2004
                                                           problem:
                                  UI_GUIFP_7
                                  10_008                          When trying to log in to the
                                                                               3
                                                                   VERITAS i login page, the
                                                                   user interface hangs.
                                                                   Additionally the CPU and
                                                                                                3
                                                                   memory usage of VERITAS i
                                                                   FocalPoint increases.
                                                           Obsolete
                                                           This patch contains all fixes that were
                                                           previously released in patch
                                                           UI_GUIFP_710_001.

 GUI        UI_GUIFP_710_003      Obsolete by    21-Dec-   This patch allows the installation of a
                                  patch          2004
                                                           Performance Warehouse on an
                                  UI_GUIFP_7               Oracle SID that contains '_'
                                  10_008                   (underscores) in its name.

                                                           Note: This patch can be installed
                                                           before or after any of the other GUI
                                                           patches.



 GUI        UI_GUIFP_710_004      Obsolete by    9-Jan-    This patch enables the installation of
                                  patch          2005
                                                           the Indepth/Oracle AppTier on an
                                  UI_GUIFP_7               Oracle Instance using a password
                                  10_008                   that starts with a digit in the password
                                                           field of the Oracle user with DBA
                                                           privileges.

                                                           Note: This patch can be installed
                                                           before or after any of the other GUI
                                                           patches.



 GUI        UI_GUIFP_710_005      Obsolete by    1-Feb-    Important:
                                  patch          2005

                                  UI_GUIFP_7
                                                           This patch adds all the user interface
                                  10_008                   files that are required for the new
                                                           features released by patch
                                                           IN_INFP_710_003.

                                                           In case you installed patch
                                                           IN_INFP_710_003, you MUST also
                                                           install this patch.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 GUI        UI_GUIFP_710_006      Obsolete by    10-Feb-   This patch solves the following
                                  patch          2005
                                                           problems:
                                  UI_GUIFP_7
                                  10_008                          When trying to launch
                                                                   SmartLink, the browser
                                                                   displays a Java Script error.

                                                                  When working with a
                                                                   Japanese user interface and
                                                                   opening the Time Frame
                                                                   Settings dialog, the Combo
                                                                   box at the bottom of screen
                                                                   does not contain any values.

                                                                  When closing the Time
                                                                   Frame Settings dialog, the
                                                                   browser displays a Java
                                                                   Script error.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 GUI        UI_GUIFP_710_008      Obsolete by    30-Mar-   This patch contains the following
                                  patch          2005
                                                           enhancements:
                                  UI_GUIFP_7
                                  10_011                          The user interface for the
                                                                   mass upgrade of the Web
                                                                   AppTier and the SQL Server
                                                                                              3
                                                                   AppTier from VERITAS i
                                                                   version 6.x. In order for this
                                                                   functionality to work, you are
                                                                   also required to install a
                                                                               3
                                                                   VERITAS i infrastructure
                                                                   patch (for more details refer
                                                                   to the Requirements section
                                                                   in the description of this
                                                                   patch).

                                                                  Two buttons, Select All and
                                                                   Deselect All, are added in
                                                                   the Select Servers screen,
                                                                   allowing the users to choose
                                                                   all the servers or remove all
                                                                   servers from the list of
                                                                   servers to be patched.

                                                           This patch solves the following
                                                           problems:

                                                                  Failure launching
                                                                   Indepth/Oracle from within
                                                                   Indepth/SAP. The launch
                                                                   failed and provided a pop-up
                                                                   window with the following
                                                                   error message:

                                                                   clsInit::getAllInclude
                                                                   s : Failed trying to
                                                                   load include...

                                                                  When launching Indepth/Web
                                                                   from Insight, the Association
                                                                   area in the launched
                                                                   workspace displays an
                                                                   internal retrieval
                                                                   error instead of the relevant
                                                                   data.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

                                                              
 GUI        UI_GUIFP_710_008        Obsolete by    30-Mar-                                    3
                                                                    Installation of VERITAS i
                                    patch          2005
            (Cont.)
                                                                    FocalPoint fails when ICMP
                                    UI_GUIFP_7                      between the windows
                                    10_011                          installation machine and the
                                                                    target machine is inhibited.
                                                                    The following error message
                                                                    appears:

                                                                    Message 168, Host
                                                                    xxx.xxx.xxx.xxx is
                                                                    unreachable.

                                                                    After applying this patch, a
                                                                    message will be displayed in
                                                                    case the ping fails, prompting
                                                                    the users to make sure the
                                                                    server exists, and allowing
                                                                    them to continue with the
                                                                    installation.

                                                                   When working with the
                                                                    Japanese user interface, the
                                                                    vertical help button overlaps
                                                                    the communication image.

                                                                   Adding a server in VERITAS
                                                                     3
                                                                    i SQL Standard Edition
                                                                    incorrectly enables you to add
                                                                    a UNIX server.

                                                                   Applying a patch sometimes
                                                                    fails, displaying a JavaScript
                                                                    error on Internet Explorer
                                                                    version 5.5.

                                                                   A JavaScript error in
                                                                    AdminPoint, sometimes
                                                                    appears during the
                                                                    Warehouse migration.

                                                                   When the installation path is
                                                                    long, the description in the
                                                                    bottom of the installation
                                                                    window is only partly
                                                                    displayed.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

                                                                 
 GUI        UI_GUIFP_710_008        Obsolete by    30-Mar-                           3
                                                                     The VERITAS i installation
                                    patch          2005
            (Cont.)
                                                                     allows the creation of files
                                                                                               3
                                    UI_GUIFP_7                       outside the VERITAS i
                                    10_011                           installation directory. After
                                                                     applying this patch, the
                                                                                  3
                                                                     VERITAS i installation
                                                                     mechanism can only create
                                                                                             3
                                                                     files in the VERITAS i
                                                                     installation folder.

                                                             Obsolete:

                                                             This patch is cumulative, and includes
                                                             all updates and fixes from the
                                                             previous patches, therefore making
                                                             them all obsolete:
                                                             UI_GUIFP_710_002,
                                                             UI_GUIFP_710_003,
                                                             UI_GUIFP_710_004,
                                                             UI_GUIFP_710_005, and
                                                             UI_GUIFP_710_006.

                                                             Requirements:

                                                             Before installing this patch, you must
                                                             install the latest cumulative VERITAS
                                                              3
                                                             i infrastructure patch. At the release
                                                             date of this patch that is the
                                                             IN_INFP_710_006 patch.

                                                             The following patches must be
                                                             installed before patch
                                                             UI_GUIFP_710_008, in case the
                                                             related products are installed:

                                                                    Insight - patch IS-ISFP-
                                                                     710-001

                                                                    Indepth/Web - patch
                                                                     WW_WWFP_710_001

                                                                    Inform/Foresight - patch
                                                                     FS_FSFP_710_003

                                                                    Indepth/SAP - patch
                                                                     SP_SPFP_710_002

                                                                    Indepth/SQL Server - patch
                                                                     SQ_MUAGS_710_001




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                  Release
  Product          Patch ID         Status                               Description
                                                   Date

 GUI        UI_GUIFP_710_011      Published       20-Jun-   This patch contains the following
                                                  2005
                                                            enhancements:

                                                                   All components that the user
                                                                    interface requires for the
                                                                    Bundle Patch installation. In
                                                                    order for this functionality to
                                                                    work, you are also required to
                                                                                         3
                                                                    install a VERITAS i
                                                                    Infrastructure patch. For more
                                                                    details, see the Requirements
                                                                    section of this description.

                                                                   The Oracle AppTier
                                                                    installation enables you to
                                                                    edit the Instance Properties
                                                                    of the Oracle home and
                                                                    Oracle listener port.

                                                                   The Web Apptier installation
                                                                    enables you to add instances
                                                                    that start with a digit or
                                                                    contain spaces in their
                                                                    names.

                                                                   Improvements to the patch
                                                                    installation screens - Adds
                                                                    View in Browser (during the
                                                                    installation phase of this
                                                                    patch, before you close and
                                                                    reopen your browser, the text
                                                                    on this button will have a
                                                                    value of RNF), increases
                                                                    column size to show the
                                                                    whole patch name, preserves
                                                                    the last path that a patch was
                                                                    installed from.

                                                            This patch solves the following
                                                            problem:

                                                                   The Gather Support
                                                                    Information dialog is missing
                                                                    a scroll bar in the list of
                                                                    Available Servers.




                                              3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID        Status                               Description
                                                     Date

 GUI        UI_GUIFP_710_011        Published       20-Jun-   Requirements
                                                    2005
            (Cont.)
                                                              This patch relies on components that
                                                                                           3
                                                              are part of the VERITAS i
                                                              Infrastructure patch
                                                              IN_INFP_710_008, and therefore
                                                              that patch must also be installed on
                                                                                3
                                                              the VERITAS i FocalPoint server (It
                                                              does not matter which patch is
                                                              installed first, as long as both are
                                                              installed).

                                                              Obsolete

                                                              This patch is cumulative, and includes
                                                              all updates and fixes released in
                                                              patch UI_GUIFP_710_008 (and all
                                                              of its predecessors), making those
                                                              patches obsolete.

 GUI        UI_GUIFP_710_012        Published(b)    22-Jul-   This patch adds the following feature:
                                    Released as     2005
                                    part of
                                    Bundle Patch                     Support for the installation of
                                    BU_I3_710_                        the Indepth/.NET Framework
                                    002                               and .NET AppTier Collector
                                                                      agents for monitoring the
                                                                      .NET technology.

                                                              For more information, refer to the
                                                              VERITAS Indepth (tm) for
                                                              .NET - Installation and
                                                              Administration Guide.

                                                              Obsolete

                                                              This patch is cumulative, and includes
                                                              all updates and fixes previously
                                                                                         3
                                                              released in the VERITAS i user
                                                              interface patches (except for the
                                                              ones released in patch
                                                              UI_GUIFP_710_011), making those
                                                              patches obsolete.




                                                3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Inform for   PF-PFFP-710-001       Obsolete by    11-Nov-   This patch solves the following
 Alerts                             patch          2004
                                                             problems:
                                    PF-PFFP-
                                    710-002                         The Inform/Alerts user
                                                                     interface stops responding
                                                                     when a parent list metric is
                                                                     viewed on the History tab.
                                                                     This problem only occurs in
                                                                                               3
                                                                     Oracle-based VERITAS i
                                                                     installations when the Oracle
                                                                     database is not located on
                                                                     the same server as
                                                                     Inform/Alerts FocalPoint.

                                                                    In the Server column, the
                                                                     SAP-related System Load
                                                                     metric displays the server ID
                                                                     instead of its name.

                                                             Note: At the end of the installation,
                                                             this patch automatically restarts
                                                             Inform/Alerts FocalPoint and, if
                                                             Indepth/SAP FocalPoint is installed,
                                                             the Inform/Alerts InformPoint on the
                                                             Indepth/SAP FocalPoint server.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                               Description
                                                    Date

 Inform for   PF-PFFP-710-002       Obsolete by    21-Dec-   This patch solves the following
 Alerts                             patch          2004
                                                             problems:
                                    PF_PFFP_7
                                    10_003                           Due to internal cleaner
                                                                      process malfunction, the
                                                                      Inform/Alerts does not delete
                                                                      old Alerts data from the
                                                                      Performance Warehouse
                                                                      database causing the user to
                                                                      still see the old data in the
                                                                      Inform/Alerts UI or get a UI
                                                                      timeout message while trying
                                                                      to show the history tab.

                                                             This patch contains all fixes that were
                                                             previously released in Patch PF-
                                                             PFFP-710-001 making that patch
                                                             Obsolete.

                                                             Notes:

                                                                     At the end of the installation
                                                                      procedure you will be
                                                                      prompted to stop the
                                                                      Inform/Alerts FocalPoint
                                                                      Agent, run a script and then
                                                                      restart the Inform/Alerts
                                                                      FocalPoint Agent.

                                                                     If the Indepth/SAP FocalPoint
                                                                      is installed, the Inform/Alerts
                                                                      InformPoint on the
                                                                      Indepth/SAP FocalPoint
                                                                      server will be automatically
                                                                      restarted at the end of the
                                                                      installation procedure.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                  Release
  Product            Patch ID        Status                              Description
                                                   Date

 Inform for   PF_PFFP_710_003      Obsolete by    21-Feb-   This patch solves the following
 Alerts                            patch          2005
                                                            problems:
                                   PF_PFFP_7
                                   10_004                          The following message
                                                                    appears in the AdminPoint
                                   which was                        IVP problem report of the
                                   published as
                                   part of
                                                                    Inform Alerts FocalPoint
                                   Bundle Patch                     agent:
                                   BU_I3_710_
                                   001
                                                            Could not perform last
                                                            Inform Alerts database clean
                                                            process. The clean process
                                                            prevents large quantities of
                                                            data in the Inform Alerts
                                                            database. Make sure the
                                                            Inform Alerts database and
                                                            its Listener agents are up.

                                                            In case this problem occurs on your
                                                            environment, the PF_PFFP_710_003
                                                            patch installation is mandatory.

                                                                   The following error message
                                                                    appears when entering the
                                                                    Inform Alerts user interface
                                                                    immediately after starting up
                                                                    Inform Alerts FocalPoint:
                                                            Error returned from Inform
                                                            Alerts FocalPoint. Check
                                                            Inform Alerts FocalPoint
                                                            logs for details.

                                                            The problem is caused by an
                                                            initialization process on the
                                                            FocalPoint server that takes too much
                                                            time and is proportional to the number
                                                            of installed Inform Alerts InformPoint
                                                            agents. The patch solves this problem
                                                            by enabling the user interface to
                                                            connect to the FocalPoint server prior
                                                            to completing this initialization
                                                            process.

                                                                   Potential synchronization
                                                                    problems have been
                                                                    eliminated by this patch.
                                                                    These problems can occur at
                                                                    situations where large
                                                                    amounts of data are handled
                                                                    by Inform Alerts FocalPoint.




                                              3
                                VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product               Patch ID        Status                              Description
                                                      Date

 Inform for   PF_PFFP_710_003         Obsolete by    21-Feb-   Obsolete:
 Alerts                               patch          2005
              (Cont.)
                                      PF_PFFP_7
                                                               This patch contains all fixes that were
                                      10_004                   previously released in patch PF-
                                                               PFFP-710-002 making that patch
                                      which was                Obsolete.
                                      published as
                                      part of
                                      Bundle Patch             Notes:
                                      BU_I3_710_
                                      001                              At the end of the installation
                                                                        procedure you will be
                                                                        prompted to stop the Inform
                                                                        Alerts FocalPoint agent, run a
                                                                        script and then restart the
                                                                        Inform Alerts FocalPoint
                                                                        agent.

                                                                       If the Indepth for SAP
                                                                        FocalPoint agent is installed,
                                                                        the Inform Alerts InformPoint
                                                                        on the Indepth for SAP
                                                                        FocalPoint server will be
                                                                        automatically restarted at the
                                                                        end of the patch installation.




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product            Patch ID         Status                              Description
                                                    Date

 Inform for   PF_PFFP_710_004       Published(b)   20-Jun-   This patch solves the following
 Alerts                             Released as    2005
                                    part of
                                                             problems:
                                    Bundle Patch
                                    BU_I3_710_                      The Indepth/J2EE metrics
                                    002                              "Application Heap
                                                                     Utilized" and
                                                                     "Application Garbage
                                                                     Collection Time" fail to
                                                                     be sampled. Therfore they
                                                                     appear as "Not Sampled" in
                                                                     the Inform/Alerts user
                                                                     interface.

                                                                    After pressing Apply all,
                                                                     metric properties for
                                                                     customized metrics are not
                                                                     updated for all instances.

                                                             Note

                                                             Installation of this patch will
                                                             automatically stop Inform/Alerts
                                                             FocalPoint, which needs to be
                                                             restarted, as described in the post-
                                                             installation action items.

                                                             Obsolete

                                                             This patch contains all fixes that were
                                                             previously released in patch
                                                             PF_PFFP_710_003 making that
                                                             patch Obsolete.

 Inform for   PU_PUPNT_710_005      Published(b)   20-Jun-   This patch solves the following
 Alerts                             Released as    2005
                                                             problem:
                                    part of
                                    Bundle Patch
                                    BU_I3_710_                      Starting Inform/Alerts
                                    002                              InformPoint agents create a
                                                                     high CPU consumption of the
                                                                                  3
                                                                     VERITAS i FocalPoint agent.
                                                                     This problem is experienced
                                                                     in installations with large
                                                                     amounts (dozens) of both
                                                                     monitored instances and
                                                                     Inform/Alerts InformPoint
                                                                     agents.

                                                             Note

                                                             Installation of this patch will
                                                             automatically stop Inform/Alerts
                                                             InformPoint.



                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                  Release
  Product            Patch ID        Status                              Description
                                                   Date

 Inform for   FS_FSFP_710_001      Obsolete by    29-Nov-   This patch enhances the process of
 Foresight                         patch          2004
                                                            sending reports via e-mail (not
                                   FS_FSFP_7                supported for Japanese installations).
                                   10_003
                                                            This patch solves the following
                                                            problems:

                                                                   Capacity planning report
                                                                    charts display dates without
                                                                    forecast values.

                                                                   When an environment or
                                                                    AppTier and a role have been
                                                                    modified, Inform/Foresight
                                                                    displays an empty report list.

                                                                   In Exception reports, the New
                                                                    Entities table is not sorted by
                                                                    entity names.

                                                                   The J2EE Application report
                                                                    shows only applications of
                                                                    type HTTP.

                                                                   The CPU usage value is
                                                                    calculated differently in SAP
                                                                    reports of Inform/Foresight
                                                                    and in Indepth/SAP. As a
                                                                    result, deviating values are
                                                                    displayed in both products.

                                                                   The CPU usage counter is
                                                                    irrelevant in long-term SAP
                                                                    Capacity Planning reports.
                                                                    This patch removes the
                                                                    counter from the report.

                                                                   SQL Object reports fail to
                                                                    launch.

                                                                   OS Exception reports
                                                                    calculate counter values
                                                                    incorrectly. Their values do
                                                                    not match the values
                                                                    displayed in the OS
                                                                    workspace of Insight.

                                                                   The OS Availability reports
                                                                    set also displays the list of the
                                                                    customized reports set.




                                              3
                                VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product               Patch ID        Status                             Description
                                                      Date

 Inform for   FS_FSFP_710_001         Obsolete by    29-Nov-         Launching from Oracle Profile
 Foresight                            patch          2004
              (Cont.)
                                                                      and Exception Storage
                                      FS_FSFP_7                       Device reports to the Storage
                                      10_003                          workspace in Indepth/Oracle
                                                                      is not possible because the
                                                                      launch button is missing.

                                                                     Oracle Object reports
                                                                      incorrectly display objects
                                                                      named "OBJECT
                                                                      NOT_SAMPLED."

                                                                     Launching from Inform/Alerts
                                                                      does not focus on the correct
                                                                      instance but opens a report at
                                                                      the beginning.

                                                                     The Filter by Object Type
                                                                      option does not work for
                                                                      Unused Objects reports. All
                                                                      object types are displayed in
                                                                      the report, regardless of the
                                                                      filtered values.

                                                                     In Exception and Capacity
                                                                      reports that display several
                                                                      charts on the same page, the
                                                                      legend does not match the
                                                                      order in the charts.

                                                                     The time frame conversion is
                                                                      incorrect for fixed period
                                                                      reports. At times, the charts
                                                                      display data that dates from
                                                                      one day before the selected
                                                                      time frame.

                                                                     The Time Frame tab in the
                                                                      Properties dialog box for
                                                                      customized reports allows
                                                                      selecting a "From" date that
                                                                      occurs after the "To" date.




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product               Patch ID        Status                             Description
                                                      Date

 Inform for   FS_FSFP_710_001         Obsolete by    29-Nov-         Saving a report to the Cross-
 Foresight                            patch          2004
              (Cont.)
                                                                      AppTiers set fails, sometimes
                                      FS_FSFP_7                       displaying the following error
                                      10_003                          message: "Unable to retrieve
                                                                      information for report. For
                                                                      details, see the log files." The
                                                                      following error message is
                                                                      written to the log and trace
                                                                      files: "ID: 2520019 Message:
                                                                      'Unable to create new
                                                                      report.'"

                                                                     When a report is deleted or
                                                                      an AppTier is uninstalled and
                                                                      then reinstalled, the alert,
                                                                      role, and summary
                                                                      information in this report is
                                                                      not updated.

                                                                     If customized reports fail to
                                                                      run, a generic "See log files"
                                                                      message appears. This patch
                                                                      replaces the message with a
                                                                      full explanation of the reason
                                                                      for the failure.

                                                                     The default cell size for dates
                                                                      in an Excel sheet does not fit
                                                                      the actual date length in
                                                                      customized reports. As a
                                                                      result, dates are displayed
                                                                      unformatted as "######".

                                                                     When a customized report is
                                                                      viewed or executed, some
                                                                      filters are processed
                                                                      incorrectly, triggering an error
                                                                      message about invalid filters.




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                  Release
  Product            Patch ID        Status                              Description
                                                   Date

 Inform for   FS_FSFP_710_003      Obsolete by    15-Feb-   This patch adds the following
 Foresight                         patch          2005
                                   FS_FSFP_7
                                                            enhancements:
                                   10_004
                                   released as                     Ability of sending reports by
                                   part of                          email, with attachments also
                                   Bundle Patch                     in Japanese characters.
                                   BU_I3_710_
                                   002
                                                                   Ability of sending customized
                                                                    reports by email.

                                                                   Web title reports: PS Panel
                                                                    and Siebel Titles were added.

                                                            This patch solves the following
                                                            problems:

                                                                   Inform/Alerts launch to the
                                                                    wrong Inform/Foresight
                                                                    report.

                                                                   Web Transactions reports
                                                                    sometimes get no results
                                                                    while they should, in Oracle
                                                                    Performance Warehouse.

                                                                   Web SAP Title reports are
                                                                    empty when no grouping is
                                                                    defined for Web SAP Titles.

                                                                   The Time Frame tab in the
                                                                    Properties dialog box for
                                                                    reports was wrongly allowing
                                                                    to select a "From" date that is
                                                                    later than the "To" date.

                                                                   Sending reports by email did
                                                                    not work when the sender
                                                                    and/or recipient address
                                                                    contained blanks.

                                                                   In SQL server unused objects
                                                                    report, selecting 'Cluster' type
                                                                    was wrongly performing like
                                                                    selecting 'All' types.




                                              3
                                VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product               Patch ID        Status                             Description
                                                      Date

 Inform for   FS_FSFP_710_003         Obsolete by    15-Feb-         In customized reports, when
 Foresight                            patch          2005
              (Cont.)                 FS_FSFP_7
                                                                      selecting a Daily, Weekly or
                                      10_004                          Monthly summary level for
                                      released as                     some of the fields fails to
                                      part of                         execute displaying a popup
                                      Bundle Patch
                                      BU_I3_710_
                                                                      error message and providing
                                      002                             the following error in the log
                                                                      file: SQL Error: ORA-00904:
                                                                      "PWGI_GMT_DIFFERENCE"
                                                                      : invalid identifier.

                                                                     In customized reports,
                                                                      selecting both of I/O wait and
                                                                      Statement fields for an Oracle
                                                                      AppTier fails to execute
                                                                      displaying a popup error
                                                                      message and providing the
                                                                      following error in the log file:
                                                                      SQL Error: ORA-00904:
                                                                      "ORSF_WAIT_IO_SUM":
                                                                      invalid identifier.

                                                               Obsolete

                                                               This patch contains all enhancements
                                                               and problem fixes that were
                                                               previously released in patch
                                                               FS_FSFP_710_001, therefore making
                                                               it Obsolete.




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                  Release
  Product            Patch ID        Status                              Description
                                                   Date

 Inform for   FS_FSFP_710_004      Published(b)   22-Jul-   This patch solves the following
 Foresight                         Released as    2005
                                   part of
                                                            problems:
                                   Bundle Patch
                                   BU_I3_710_                      When there is only one
                                   002                              regression point, there is no
                                                                    forecast displayed in the
                                                                    graph in the Capacity
                                                                    Planning report.

                                                                   Modifying the properties of a
                                                                    report from different
                                                                    environments, causes the
                                                                    Parameters screen to display
                                                                    certain identical fields more
                                                                    than once.

                                                                   Modifying the properties of a
                                                                    report and clearing the first
                                                                    checkbox that is displayed on
                                                                    the General tab, causes the
                                                                    execution of the report to fail.
                                                                    A
                                                                    "NullPointerException"
                                                                    is entered in the
                                                                    foresight.fp.trc file.
                                                                    The user gets error ID 28008
                                                                    with the following message:

                                                                    Unable to process
                                                                    report query or
                                                                    handled retrieved
                                                                    report data.




                                              3
                                VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product               Patch ID        Status                             Description
                                                      Date

 Inform for   FS_FSFP_710_004         Published(b)   22-Jul-         When the J2EE Application
 Foresight                            Released as    2005
              (Cont.)                 part of
                                                                      report is produced with the
                                      Bundle Patch                    option of Poor Service
                                      BU_I3_710_                      counter checked (the default)
                                      002                             and there is more than one
                                                                      J2EE instance available, the
                                                                      user gets error ID 28008 with
                                                                      the following message:

                                                                      Unable to process
                                                                      report query or
                                                                      handled retrieved
                                                                      report data.

                                                                      An error is entered in the
                                                                      foresight.fp.trc file, for
                                                                      example:

                                                                      The name
                                                                      Summary_prod21synch1
                                                                      Running on
                                                                      fawsbusp27_Poor
                                                                      Service has no local
                                                                      destination.

                                                                     The text of the first page of
                                                                      the Web Capacity Planning
                                                                      report overflows the page
                                                                      scope.

                                                                     The following error message
                                                                      is displayed when choosing a
                                                                      different value than All in the
                                                                      Analyze the following hour
                                                                      groups only field (on the
                                                                      Time Frame tab of the report
                                                                      properties) for a Capacity
                                                                      Planning report for Web,
                                                                      Oracle Applications,
                                                                      Operating System, and
                                                                      Tuxedo:

                                                                      Unable to save report
                                                                      changes. For details,
                                                                      see the log file.




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product               Patch ID        Status                            Description
                                                      Date

 Inform for   FS_FSFP_710_004         Published(b)   22-Jul-          and the following error
 Foresight                            Released as    2005
              (Cont.)                 part of
                                                                      example is entered in the
                                      Bundle Patch                    foresight.fp.trc file:
                                      BU_I3_710_
                                      002                             Msg: Unable to process
                                                                      query or retrieve data
                                                                      of report: 1049_603.
                                                                      Exception : ORA-00904:
                                                                      SUMMARY. TUAC_PWHG_ID:
                                                                      invalid identifier.

                                                                     Launching from Web title
                                                                      reports (PS Panel and Siebel
                                                                      Titles) into Indepth/Web
                                                                      displays error messages
                                                                      beginning with:

                                                                      clsInit... Failed
                                                                      trying to load
                                                                      include.

                                                                      and then an error message:

                                                                      Invalid product code.

                                                                     When the URL is NULL, the
                                                                      linking of the Page and URL
                                                                      fields creates a NULL string
                                                                      in the Web Page and URL
                                                                      reports.

                                                                     The SQL Server Unused
                                                                      Objects report is
                                                                      unnecessary, displaying
                                                                      Objects that are related to
                                                                                3
                                                                      VERITAS i .

                                                                     Statements that are
                                                                      generated by Indepth/Oracle
                                                                      are unnecessarily included in
                                                                      all Oracle Statements reports.




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product               Patch ID        Status                             Description
                                                      Date

 Inform for   FS_FSFP_710_004         Published(b)   22-Jul-   This patch solves the following
 Foresight                            Released as    2005
              (Cont.)                 part of
                                                               problems in customized reports:
                                      Bundle Patch
                                      BU_I3_710_                     The Indepth/Oracle Work
                                      002                             Type identifier is not including
                                                                      Siebel work types.

                                                                     In Japanese environments, in
                                                                                            3
                                                                      which the VERITAS i
                                                                      Performance Warehouse is
                                                                      based on SQL Server, error
                                                                      ID 28057 (with a Japanese
                                                                      message) is displayed, when
                                                                      trying to include a date type
                                                                      field in the customized report.

                                                                     When editing the SQL
                                                                      SELECT statement,
                                                                      automatically created for
                                                                      retrieving the data for the
                                                                      customized report from the
                                                                      Performance Warehouse,
                                                                      and changing the aliases of
                                                                      the columns, an error occurs
                                                                      when rerunning the report,
                                                                      displaying the following error
                                                                      message:

                                                                      Unable to process
                                                                      report query or handle
                                                                      retrieved report data

                                                                      The message in the
                                                                      foresight.fp.trc file is:

                                                                      Msg : Unable to save
                                                                      report: 1049_100116.
                                                                      Exception : null Frame
                                                                      :
                                                                      com.precise.fs.repgen.
                                                                      RepGenException




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product               Patch ID        Status                             Description
                                                      Date

 Inform for   FS_FSFP_710_004         Published(b)   22-Jul-          When executing a
 Foresight                            Released as    2005
              (Cont.)                 part of
                                                                       customized report,
                                      Bundle Patch                     connections to the
                                      BU_I3_710_                       Performance Warehouse
                                      002                              database are not freed. After
                                                                       several executions of those
                                                                       customized user defined
                                                                       report(s), the user gets error
                                                                       ID 28008 with the following
                                                                       message:

                                                               Unable to process report
                                                               query or handled retrieved
                                                               report data.

                                                               The message in the
                                                               foresight.fp.trc file is:

                                                               Too many processes...

                                                               Obsolete

                                                               This patch is cumulative, and includes
                                                               all enhancements and fixes that were
                                                               previously released in patch
                                                               FS_FSFP_710_003 (and all of its
                                                               predecessors), therefore making that
                                                               patch obsolete.




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 Insight    IS-ISFP-710-001       Obsolete by    01-Nov-   This patch enables the display of
                                  patch          2004
                                                           "Database Time" in Insight/SmartLink
                                  IS_ISFP_710              for Web Applications, for all database
                                  _007                     configurations.

                                                           This patch solves the following
                                                           problems:

                                                                  Insight loads values of "?"
                                                                   (question marks) into to
                                                                   Performance Warehouse
                                                                   instead of the actual non-
                                                                   English characters.

                                                                  Corruption of
                                                                   Insight/SmartLink data.

                                                                  The Insight User Interface
                                                                   filter dialog box could not be
                                                                   activated when an
                                                                   environment contained an OS
                                                                   AppTier.

                                                                  Insight/SmartLink for Web
                                                                   displays statements with a
                                                                   value of "No Statement"
                                                                   instead of their actual value.

                                                                  Availability agent
                                                                   configurations could not be
                                                                   activated.

                                                                  Availability alerts were
                                                                   reported for Insight
                                                                   technologies (MQ, Tuxedo or
                                                                   Oracle Applications) without
                                                                   an indication of the
                                                                   technology's status.

                                                                  Incorrect baseline data.

                                                                  Web Network bytes field was
                                                                   displaying inaccurate values.

                                                                  The graph for the PeopleSoft
                                                                   pages displayed "(No
                                                                   PeopleSoft Page)" if the
                                                                   PeopleSoft Web server was
                                                                   monitored by both server-side
                                                                   and client-side
                                                                   instrumentation.



                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS-ISFP-710-001         Obsolete by    01-Nov-         An upgrade of a Tuxedo
                                    patch          2004
                                                                    instance wrongly identified
            (cont.)
                                    IS_ISFP_710                     two fields as mandatory.
                                    _007
                                                                   Filtering SQL server
                                                                    statements caused an error if
                                                                    baseline was enabled.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 Insight    IS-MUAGS-710-002      Obsolete by    01-Nov-   Note::
                                  patch          2004
                                                           All Insight agents will be automatically
                                  IS_MUAGS_                stopped on the patched server.
                                  710_008                  All Insight agents will be automatically
                                                           started on the patched server after
                                                           the installation of this patch except
                                                           Insight/OS agent on Linux, SunOs
                                                           and AIX platforms.

                                                           This patch adds support to the
                                                           following issues:

                                                                  Monitor Tuxedo 6.5 64 bit on
                                                                   HP-UX, SunOS and AIX
                                                                   platforms.
                                                                   Note: : In case you are
                                                                   planning to install this patch
                                                                   for the support of the Tuxedo
                                                                   version, you must first install
                                                                   patch UI-GUIFP-700-001 on
                                                                   your VERITAS i3 Focal Point
                                                                   Server
                                                           This patch solves the following
                                                           problems:

                                                                  Missing of J2EE data in
                                                                   Insight UI due to a
                                                                   synchronization problem
                                                                   between Insight/J2ee agent
                                                                   and Indepth/J2ee FocalPoint.

                                                                  Missing of Oracle
                                                                   Applications data in Insight UI
                                                                   due to a synchronization
                                                                   problem between Insight/OA
                                                                   agent and Indepth/Oracle
                                                                   FocalPoint.

                                                                  MQ queues appear in the
                                                                   Insight UI as "_I3OTHER_"
                                                                   due to an unnecessary
                                                                   filtering of queue names in
                                                                   Insight/MQ agent.

                                                                  Inaccurate network time
                                                                   calculation for Oracle
                                                                   Applications and Web
                                                                   communication on the Linux
                                                                   platform.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS-MUAGS-710-002        Obsolete by    01-Nov-          Non-English characters are
                                    patch          2004
            (cont.)
                                                                     displayed as '?' in the
                                    IS_MUAGS_                        command line attribute of
                                    710_008                          processes in Insight/OS UI.

                                                                    Inaccurate calculations of
                                                                     average counters of OS
                                                                     metrics.

                                                                    Inaccurately measure of cpu
                                                                     time for process running on
                                                                     Linux platforms.

                                                                    Inaccurate server load
                                                                     counter might be displayed in
                                                                     Insight/OS for Linux servers.



 Insight    IS-ISOS-710-003         Obsolete by    12-Dec-   This patch solves the following
                                    patch          2004
                                                             problem:
                                    IS_MUAGS_
                                    710_008                         The Insight/OS agent may fail
                                                                     to sample the process table
                                                                     on HPUX 11.X, 64-bit
                                                                     servers. For these servers, no
                                                                     operating system information
                                                                     is available in Insight.

                                                             Note: The patch installation
                                                             procedure automatically stops the
                                                             Insight/OS agent, extracts the patch,
                                                             and then restarts the Insight/OS
                                                             agent. Manual pre- or post-installation
                                                             tasks are not required




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 Insight    IS_ISTCP_710_004      Obsolete by    16-Jan-   This is a mandatory patch.
                                  patch          2005

                                  IS_MUAGS_
                                                           This patch solves the following
                                  710_008                  problems:

                                                                  Network data is not available
                                                                   in the Insight UI because of
                                                                   detection failures in the
                                                                   Insight Network Agent, such
                                                                   as:
                                                                           Detection of IP
                                                                            addresses on Non-
                                                                            English Unix
                                                                            Operating systems.

                                                                           Detection of network
                                                                            devices that include
                                                                            the characters 'l' or 'o'
                                                                            in their names on
                                                                            Linux Operating
                                                                            systems.

                                                                           Detection of virtual IP
                                                                            addresses on HP-UX
                                                                            Operating systems.

                                                                  Calculation of network time is
                                                                   longer than the real network
                                                                   time.

                                                           Note: The Insight network agent will
                                                           be stopped and restarted
                                                           automatically during the installation of
                                                           the patch.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 Insight    IS_ISOS_710_005       Obsolete by    15-Feb-   This patch enhances the Insight/OS
                                  patch          2005
                                                           agent to support all Linux Red Hat
                                  IS_MUAGS_                AS2.1 and AS3 versions, not
                                  710_008                  depending on the Linux kernel
                                                           version.

                                                           All Insight/OS agents without this
                                                           patch fully depend on the Linux kernel
                                                           version.

                                                           Important:

                                                                  First install the Insight/OS
                                                                   agent on all Linux servers you
                                                                   wish to sample (by checking
                                                                   the "Install OS agent on this
                                                                   server" option in the Server -
                                                                   Extensions installation
                                                                   screen).

                                                                  During the installation of the
                                                                   Linux server, you will receive
                                                                   the following error message
                                                                   (Message No: 1139) in the
                                                                               3
                                                                   VERITAS i Agent Installer,
                                                                   should your Linux kernel not
                                                                   be supported:
                                                           "The Insight/OS agent does
                                                           not support operating system
                                                           version <the Linux version
                                                           of your server>. Re-Install
                                                           the server without the
                                                           Insight/OS agent".

                                                                  Click Ignore on this message

                                                                  Continue to install the server
                                                                   with the Insight/OS agent
                                                                   option.

                                                                  Ignore the post-installation
                                                                   action item that directs you to
                                                                   run the following command:
                                                           ./os_root.sh

                                                                  Install patch IS-MUAGS-
                                                                   710-002 on the Linux server.

                                                                  Install this patch on the Linux
                                                                   server.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                               Description
                                                  Date

 Insight    IS_ISTUX_710_006      Obsolete by    10-Feb-   This patch solves the following
                                  patch          2005
                                                           problem:
                                  IS_MUAGS_
                                  710_008                         On UNIX platforms, the
                                                                   Insight/Tuxedo agent crashes
                                                                   during the startup process in
                                                                   case it is installed for
                                                                   monitoring a Tuxedo 8.1
                                                                   domain configured to have a
                                                                   large shared memory (more
                                                                   than 1 MB).

                                                           Note: The Insight/Tuxedo agent will
                                                           automatically be stopped and then
                                                           restarted during the installation of this
                                                           patch on the server.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 Insight    IS_ISFP_710_007       Obsolete by    15-Apr-   This patch solves the following
                                  patch          2005
                                                           problems:
                                  IS_ISFP_710
                                  _010 which                      Insight/SmartLink loads
                                  was                              corrupted records into the
                                  published as                     Performance Warehouse.
                                  part of
                                  Bundle Patch                     The problem causes a
                                  BU_I3_710_                       significant increase in the size
                                  001                              of the Performance
                                                                   Warehouse database.

                                                                  The hash value of an SQL
                                                                   statement in
                                                                   Insight/SmartLink for Web
                                                                   environments can differ from
                                                                   the value for the same SQL
                                                                   statement in Indepth/Oracle.
                                                                   This causes the
                                                                   Indepth/Oracle user interface
                                                                   to display "No data found"
                                                                   or only partial information,
                                                                   when launched from the
                                                                   Insight user interface.

                                                                  High CPU consumption of
                                                                   Insight FocalPoint, if
                                                                   Insight/SmartLink for Web
                                                                   environments is enabled for
                                                                   applications, which do not
                                                                   use bind variables in SQL
                                                                   statements.

                                                                  Insight FocalPoint hangs at
                                                                   startup, showing the "starting"
                                                                   status in AdminPoint.

                                                                  The Insight user interface
                                                                   displays performance data,
                                                                   which is not part of the active
                                                                   environment. Clicking "Verify"
                                                                   in AdminPoint for Insight
                                                                   FocalPoint will display the
                                                                   following:
                                                           The Performance Warehouse
                                                           environment tables are not
                                                           consistent with the Insight
                                                           environment tables. It can
                                                           cause a lack of expected
                                                           information in Insight UI.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

                                                              
 Insight    IS_ISFP_710_007         Obsolete by    15-Apr-                                     3
                                                                    The upgrade of VERITAS i
                                    patch          2005
            (cont.)
                                                                    components from version 6.x
                                    IS_ISFP_710                     fails, in one of the following
                                    _010 which                      situations:
                                    was
                                    published as                           The upgrade of a
                                    part of
                                    Bundle Patch                            server with OS or
                                    BU_I3_710_                              Network add-on -
                                    001                                     When the upgraded
                                                                            server name starts
                                                                            with a digit (such as
                                                                            an IP address).

                                                                           The upgrade of an
                                                                            AppTier instance,
                                                                            such as Tuxedo,
                                                                            Oracle Applications
                                                                            and Other - When the
                                                                            upgraded instance
                                                                            server name starts
                                                                            with a digit.

                                                                           The upgrade of
                                                                            Indepth/J2EE
                                                                            FocalPoint with the
                                                                            Insight integration
                                                                            checked - When the
                                                                            server name of
                                                                            Indepth/J2EE
                                                                            FocalPoint starts with
                                                                            a digit.

                                                                   The AppTiers entity in the
                                                                    Network AppTier area is
                                                                    incorrectly displaying the
                                                                    performance information of
                                                                    the instances.

                                                                   Indepth/Web displays the "No
                                                                    data found" error, when
                                                                    launched from the Insight
                                                                    user interface. This mainly
                                                                    occurs in Siebel
                                                                    environments.

                                                                   The Insight user interface
                                                                    displays an error "Unable
                                                                    to execute a query",
                                                                    when viewing Baseline data,
                                                                    in installations, where the
                                                                    Performance Warehouse is
                                                                    installed on an SQL Server.



                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS_ISFP_710_007         Obsolete by    15-Apr-   Requirements
                                    patch          2005
            (cont.)
                                    IS_ISFP_710
                                                             This patch must be applied along
                                                                                                  3
                                    _010 which               with the latest cumulative VERITAS i
                                    was                      user interface patch. At the release
                                    published as             date of this patch, that is the
                                    part of
                                    Bundle Patch
                                                             UI_GUIFP_710_008 patch.
                                    BU_I3_710_
                                    001                      Obsolete

                                                             This patch is a cumulative patch and
                                                             contains all enhancements and
                                                             problem fixes that were previously
                                                             released in patch IS-ISFP-710-
                                                             001, therefore making it obsolete.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 Insight    IS_MUAGS_710_008      Obsolete by    15-Apr-   This patch is a cumulative patch that
                                  patch          2005
                                                           contains enhancements and fixes
                                  IS_MUAGS_                problems in Insight agents for the
                                  710_011                  following AppTiers: MQ, Oracle
                                  which was                Applications, J2EE, Tuxedo, Network
                                  published as
                                                           and OS.
                                  part of
                                  Bundle Patch
                                  BU_I3_710_               The patch solves the following
                                  001                      problems:

                                                                  Missing J2EE method
                                                                   invocations.

                                                                  The Insight MQ agent can
                                                                   cause memory leaks in
                                                                   programs that use MQ.

                                                                  The Insight OS agent
                                                                   incorrectly reports "Invalid
                                                                   records" for reaching CPU
                                                                   consumption limits. The
                                                                   following error message
                                                                   appears in the Insight agent
                                                                   log:

                                                                           ID : WARNING-
                                                                           3000335
                                                                           Process :
                                                                           ../bin/psi_os
                                                                           Msg : Agent
                                                                           received invalid
                                                                           record. Invalid
                                                                           field name: All
                                                                           processes cpu-
                                                                           time
                                                                           (29629.888672)
                                                                           exceeded max
                                                                           cpu-time
                                                                           (10800).

                                                           Requirements

                                                           This patch must be applied along
                                                                                                3
                                                           with the latest cumulative VERITAS i
                                                           user interface patch. At the release
                                                           date of this patch, that is the
                                                           UI_GUIFP_710_008 patch.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS_MUAGS_710_008        Obsolete by    15-Apr-   Important
                                    patch          2005
            (cont.)
                                    IS_MUAGS_
                                                             The post-installation action items are
                                    710_011                  displayed according to the installed
                                    which was                Insight agents on the patched server.
                                    published as             The following list is an overview of the
                                    part of
                                    Bundle Patch
                                                             action items that will be required to be
                                    BU_I3_710_               preformed for the different
                                    001                      configurations.

                                                                    If the patched server is Sun
                                                                     or AIX and the Insight OS
                                                                     agent is installed:
                                                                         1. Log in as root.

                                                                         2. Run the following
                                                                            commands:

                                                                                     cd <i3
                                                                                      root>/prod
                                                                                      ucts/insig
                                                                                      ht/install

                                                                                     ./os_root.
                                                                                      sh

                                                                         3. Use AdminPoint to
                                                                            restart the Insight/OS
                                                                            agent on the patched
                                                                            server.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS_MUAGS_710_008        Obsolete by    15-Apr-         If the patched server is
                                    patch          2005
                                                                    Linux, the Insight OS agent
            (cont.)
                                    IS_MUAGS_                       is installed, and the Insight
                                    710_011                         OS agent is using the Insight
                                    which was                       OS kernel module to monitor
                                    published as
                                    part of
                                                                    the server:
                                    Bundle Patch
                                    BU_I3_710_                         1. Log in as root.
                                    001
                                                                       2. Run the following
                                                                          commands:

                                                                                  cd <i3
                                                                                   root>/prod
                                                                                   ucts/insig
                                                                                   ht/install

                                                                                  ./psimod_u
                                                                                   ninstall.s
                                                                                   h

                                                                                  ./os_root.
                                                                                   sh

                                                                       3. Use AdminPoint to
                                                                          restart the Insight/OS
                                                                          agent on the patched
                                                                          server.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS_MUAGS_710_008        Obsolete by    15-Apr-         If the patched server is UNIX
                                    patch          2005
                                                                    and the Insight MQ agent is
            (cont.)
                                    IS_MUAGS_                       installed:
                                    710_011
                                    which was                           1. Stop all monitored
                                    published as                           queue managers.
                                    part of
                                    Bundle Patch                        2. Log in as mqm user.
                                    BU_I3_710_
                                    001
                                                                        3. Run the following
                                                                           commands:

                                                                                   cd <i3
                                                                                    root>/prod
                                                                                    ucts/insig
                                                                                    ht/bin

                                                                                   cp
                                                                                    psi_mq_exi
                                                                                    ts* <MQ
                                                                                    lib
                                                                                    directory>
                                                                                    (default:/
                                                                                    var/mqm/ex
                                                                                    its)

                                                                        4. Start all monitored
                                                                           queue managers.

                                                                   If the patched server is
                                                                    Windows and the Insight
                                                                    MQ agent is installed:
                                                                        1. Start all monitored
                                                                           queue managers.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 Insight    IS_MUAGS_710_008        Obsolete by    15-Apr-   Notes
                                    patch          2005
            (cont.)
                                    IS_MUAGS_                       After the installation of this
                                    710_011                          patch, all Insight agents will
                                    which was                        automatically be stopped and
                                    published as                     restarted on the patched
                                    part of
                                    Bundle Patch                     server. Except for the
                                    BU_I3_710_                       Insight/OS agent. This agent
                                    001                              will not be started
                                                                     automatically on Linux, Sun
                                                                     and AIX platforms and must
                                                                     be started manually, after the
                                                                     patch installation has been
                                                                     finished.

                                                                    In case you install this patch
                                                                     to monitor Linux Red Hat
                                                                     AS2.1 or AS3 servers with an
                                                                     Insight/OS agent that does
                                                                     not depend on the Linux
                                                                     kernel version, first perform
                                                                     the following procedure:
                                                                            Install the Insight/OS
                                                                             agent on all Linux
                                                                             servers, you wish to
                                                                             monitor. During the
                                                                             installation of the
                                                                             Linux server via the
                                                                                          3
                                                                             VERITAS i Agent
                                                                             Installer, you will
                                                                             receive an error
                                                                             message (Message
                                                                             No: 1139) with the
                                                                             following text:
                                                             "The Insight/OS agent does
                                                             not support operating system
                                                             version <the Linux version
                                                             of your server>. Re-Install
                                                             the server without the
                                                             Insight/OS agent".




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 Insight    IS_MUAGS_710_008        Obsolete by    15-Apr-                  Click ignore on this
                                    patch          2005                      message and
            (cont.)                                                          continue to install the
                                    IS_MUAGS_                                server with the OS
                                    710_011
                                    which was                                agent option. During
                                    published as                             this installation, also
                                    part of                                  ignore the post-
                                    Bundle Patch                             installation action
                                    BU_I3_710_
                                    001                                      item that directs you
                                                                             to run the following
                                                                             command:
                                                             ./os_root.sh

                                                                            Continue with this
                                                                             patch installation and
                                                                             perform the post-
                                                                             installation action
                                                                             items, if instructed.

                                                             Obsolete

                                                             This patch is cumulative, and includes
                                                             all updates and fixes from the patches
                                                             IS-MUAGS-710-002, IS-ISOS-
                                                             710-003, IS_ISTCP_710_004,
                                                             IS_ISOS_710_005, and
                                                             IS_ISTUX_710_006, making those
                                                             patches obsolete.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                             Description
                                                  Date

 Insight    IS_MUAGS_710_009      Obsolete by    6-May-    This patch is a cumulative patch for
                                  patch          2005
                                                           Linux platforms only. The patch
                                  IS_MUAGS_                includes the following enhancements:
                                  710_011
                                  which was                      Enhances all Insight agents
                                  published as                    to support Linux platforms
                                  part of
                                  Bundle Patch                    based on kernel 2.6.
                                  BU_I3_710_
                                  001                            Enhances the Insight OS
                                                                  agent to support Linux Red
                                                                  Hat 8, Red Hat 9, and Suse
                                                                  8.X, based on the kernels 2.4
                                                                  and 2.6, regardless of the
                                                                  kernel sub version.

                                                           For the complete information on Linux
                                                           platform support, please refer to the
                                                                      3
                                                           VERITAS i Support Matrix.

                                                           Important

                                                                 When adding a new server
                                                                  before applying this patch,
                                                                  you will encounter
                                                                  "unsupported error"
                                                                  messages during the
                                                                  installation of the server with:

                                                                          The Insight OS Add-
                                                                           On (error number -
                                                                           1139).

                                                                          The Insight Network
                                                                           Add-On (error
                                                                           number - 1117).

                                                                          A general agent
                                                                           (error number -
                                                                           11347).




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS_MUAGS_710_009        Obsolete by    6-May-           In order to install any Insight
                                    patch          2005
            (cont.)
                                                                     agents on Linux servers,
                                    IS_MUAGS_                        which are not already part of
                                                                                      3
                                    710_011                          your VERITAS i installation,
                                    which was                        perform the following
                                    published as
                                    part of
                                                                     procedure before you
                                    Bundle Patch                     continue with this patch
                                    BU_I3_710_                       installation:
                                    001
                                                                         1. Close the patch
                                                                            installation dialog.

                                                                         2. Use the Agent
                                                                            Installer to add the
                                                                            Linux servers you
                                                                            wish to monitor
                                                                            without Insight OS
                                                                            and Insight Network
                                                                            Add-Ons.

                                                                         3. Close the Agent
                                                                            Installer and install
                                                                            the patch on those
                                                                            servers.

                                                                         4. In case you need to
                                                                            configure the server
                                                                            with the Insight OS or
                                                                            Insight Network Add-
                                                                            On, open the Agent
                                                                            Installer and edit the
                                                                            server properties and
                                                                            add the Insight OS
                                                                            and/or Insight
                                                                            Network Add-On.

                                                                    When applying this patch on
                                                                     existing servers that already
                                                                     have the Insight Network
                                                                     Add-On or MQ or Tuxedo
                                                                     AppTier, you will need to
                                                                     perform the action items that
                                                                     are listed in the post-
                                                                     installation stage.

                                                             Notes

                                                                    During the installation of this
                                                                     patch, all Insight agents will
                                                                     automatically be stopped on
                                                                     the server to be patched.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 Insight    IS_MUAGS_710_009        Obsolete by    6-May-    Obsolete
                                    patch          2005
            (cont.)
                                    IS_MUAGS_
                                                             This patch is a cumulative patch for
                                    710_011                  Linux platforms only and contains
                                    which was                all enhancements and problem fixes
                                    published as             that were previously released in patch
                                    part of
                                    Bundle Patch             IS_MUAGS_710_008, therefore
                                    BU_I3_710_               making that patch obsolete for the
                                    001                      Linux platform only.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 Insight    IS_ISFP_710_010       Obsolete by    20-Jun-   This patch contains the following
                                  patch          2005
                                  IS_ISFP_710
                                                           enhancements:
                                  _012
                                  released as                     Improvements to the clarity of
                                  part of                          the warning and error
                                  Bundle Patch                     messages, as written by
                                  BU_I3_710_
                                  002                              Insight FocalPoint to the
                                                                   Insight log and trace files.

                                                                  Improvements to the clarity of
                                                                   verification messages, as
                                                                   displayed when verifying
                                                                   Insight FocalPoint from
                                                                   AdminPoint.

                                                           This patch solves the following
                                                           problems:

                                                                  When viewing the Flow
                                                                   station on installations of
                                                                   Insight/SmartLink for Web
                                                                   Applications, where
                                                                   Indepth/Oracle is not
                                                                   installed, the following error is
                                                                   displayed:

                                                           Unable to execute a query.

                                                                  Data collection and loading of
                                                                   Insight AppTiers stops,
                                                                   because of lingering files in
                                                                   the load directory
                                                                   (products\insight\Foca
                                                                   lPoint\data_files\load
                                                                   ).

                                                                  On installations where
                                                                   SmartLink is enabled, data
                                                                   collection and loading of
                                                                   Insight AppTiers stops and
                                                                   one or more of the following
                                                                   errors are written to the
                                                                   Insight FocalPoint and Insight
                                                                   agent log files:

                                                                           Did not create
                                                                            TAC file for
                                                                            instance
                                                                            TuxedoPeopleSoft
                                                                            reason is :
                                                                            total TAC files
                                                                            reach max count.



                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 Insight    IS_ISFP_710_010         Obsolete by    20-Jun-                  Failed to send
                                    patch          2005                      data record to
            (cont.)                 IS_ISFP_710
                                    _012                                     Insight
                                    released as                              FocalPoint due
                                    part of                                  to unable to
                                    Bundle Patch                             create file.
                                    BU_I3_710_
                                    002                                      Record discarded
                                                                             (18775).

                                                                            XML Record was
                                                                             not written.
                                                                             Lock limit for
                                                                             this time slice
                                                                             reached.

                                                                            The following
                                                                             signature file
                                                                             has no data file
                                                                             and will be
                                                                             deleted:...

                                                                            The file
                                                                             transfer process
                                                                             has been unable
                                                                             to harvest files
                                                                             from the server:
                                                                             (Server Name).

                                                             Notes

                                                                    This patch will stop and then
                                                                     restart Insight FocalPoint.

                                                                    This patch will stop and then
                                                                     restart Indepth/Oracle
                                                                     FocalPoint, Indepth/SQL
                                                                     Server FocalPoint, and
                                                                     Indepth/Web FocalPoint, if
                                                                     installed on the same
                                                                     machine as Insight
                                                                     FocalPoint.

                                                                    If patch IS_ISFP_710_007
                                                                     has not been installed
                                                                     already, you are required to
                                                                     restart all monitored JVMs
                                                                     that belong to the J2EE
                                                                     AppTier, on which
                                                                     Insight/SmartLink for Web
                                                                     Applications has been
                                                                     enabled.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 Insight    IS_ISFP_710_010         Obsolete by    20-Jun-   Obsolete
                                    patch          2005
            (cont.)                 IS_ISFP_710
                                    _012
                                                             This patch is cumulative, and includes
                                    released as              all enhancements and fixes that were
                                    part of                  previously released in patch
                                    Bundle Patch             IS_ISFP_710_007, therefore
                                    BU_I3_710_
                                    002                      making that patch obsolete.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product          Patch ID         Status                              Description
                                                  Date

 Insight    IS_MUAGS_710_011      Obsolete by    20-Jun-   This patch is a cumulative patch that
                                  patch          2005
                                  IS_MUAGS_
                                                           contains enhancements and fixes
                                  710_013                  problems in Insight agents for the
                                  released as              following AppTiers: MQ, Oracle
                                  part of                  Applications, J2EE, Tuxedo, Network,
                                  Bundle Patch
                                                           and OS.
                                  BU_I3_710_
                                  002
                                                           This patch adds support for the
                                                           following:

                                                                  Tuxedo activity can be
                                                                   associated with network
                                                                   activity for Tuxedo 6.5 64-bit
                                                                   that uses Jolt.

                                                                  Network and Oracle
                                                                   Applications monitoring on
                                                                   AIX 5.3 64-bit.

                                                           This patch contains the following
                                                           enhancements:

                                                                  Improvements to the clarity of
                                                                   the warning and error
                                                                   messages, as written by
                                                                   Insight Agents to the Insight
                                                                   log and trace files.

                                                                  Improvements to the clarity of
                                                                   verification messages, as
                                                                   presented when verifying the
                                                                   Insight agents via
                                                                   AdminPoint.

                                                           This patch solves the following
                                                           problems:

                                                                  An incorrect calculation of
                                                                   Tuxedo invocation time, if
                                                                   parallel or a-synchronic
                                                                   server process calls are
                                                                   made.

                                                                  The Insight Tuxedo agent log
                                                                   files are not purged and
                                                                   cause a disk space problem.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS_MUAGS_710_011        Obsolete by    20-Jun-         A crash of AIX servers,
                                    patch          2005
                                    IS_MUAGS_
                                                                    caused by the Insight
            (cont.)
                                    710_013                         Network kernel module. The
                                    released as                     Insight Network agent detects
                                    part of                         possible problems in the
                                    Bundle Patch
                                    BU_I3_710_
                                                                    Network kernel module and
                                    002                             disables itself to prevent a
                                                                    crash. The Network agent is
                                                                    marked with the fault status
                                                                    and the following error
                                                                    message is written to the log
                                                                    file:

                                                                    ID : SEVERE-3000202
                                                                    Msg : Function failed
                                                                    in duty: The Insight
                                                                    kernel module sanity
                                                                    check failed
                                                                    (status=450). Insight
                                                                    Network agent will
                                                                    disable itself until
                                                                    further notice.
                                                                    Contact Veritas
                                                                    Technical Support.

                                                                   Insight agents do not collect
                                                                    performance data and report
                                                                    "Invalid record" errors.
                                                                    The errors occur in one of the
                                                                    following cases:

                                                                        1. There is a difference
                                                                           of more than 7 hours
                                                                           between the Insight
                                                                           agent server UTC
                                                                           clock and
                                                                                           3
                                                                           the VERITAS i
                                                                           FocalPoint UTC
                                                                           clock.

                                                                        2. There is no activity in
                                                                           the monitored
                                                                           AppTier for 7 hours
                                                                           or more, and the
                                                                           activity of the first
                                                                           time slice is not
                                                                           collected.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS_MUAGS_710_011        Obsolete by    20-Jun-           The following error message
                                    patch          2005
                                    IS_MUAGS_
                                                                     is written to the log file:
            (cont.)
                                    710_013
                                    released as                      ID : SEVERE-3000335
                                    part of                          Msg : Agent received
                                    Bundle Patch                     invalid record.
                                    BU_I3_710_                       Invalid field name:
                                    002
                                                                     start_time.sec.

                                                                    File Handles leak in the
                                                                     Insight OS agent for AIX.

                                                                    The installation of the Insight
                                                                     Network agent fails to detect
                                                                     IP addresses in HP-UX
                                                                     servers, and no network data
                                                                     is collected for the servers.

                                                                     The following error message
                                                                     is written to the log file:

                                                                     ID : SEVERE-3000268
                                                                     Msg : Invalid net mng
                                                                     id record "ifc 800 1"
                                                                     in file
                                                                     etc/interfaces.cfg.

                                                             Important

                                                             The post-installation action items are
                                                             displayed according to the installed
                                                             Insight agents on the patched server.
                                                             The following list is an overview of the
                                                             action items that are required to be
                                                             performed for the different
                                                             configurations.

                                                                    If the patched server is AIX
                                                                     and the Insight Network
                                                                     agent is installed:

                                                                 1. Log on as root.

                                                                 2. Run the following commands:

                                                                         a. cd <i3
                                                                            root>/products/i
                                                                            nsight/<local
                                                                            server
                                                                            name>/kernel

                                                                         b. ./uninstall_drv.
                                                                            sh



                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS_MUAGS_710_011        Obsolete by    20-Jun-              c.   cd <i3
                                    patch          2005
                                    IS_MUAGS_
                                                                             root>/products/i
            (cont.)
                                    710_013                                  nsight/install
                                    released as
                                    part of                             d. ./network_root.s
                                    Bundle Patch                           h
                                    BU_I3_710_
                                    002
                                                              3. Use AdminPoint to restart the
                                                                 Insight/Network agent on the
                                                                 patched server.

                                                                   If the patched server is Sun
                                                                    or AIX and the Insight OS
                                                                    agent is installed:

                                                              1. Log on as root.

                                                              2. Run the following commands:

                                                                        a. cd <i3
                                                                           root>/products/i
                                                                           nsight/install

                                                                        b. ./os_root.sh

                                                              3. Use AdminPoint to restart the
                                                                 Insight/OS agent on the
                                                                 patched server.

                                                                   If the patched server is Linux
                                                                    and the Insight Network
                                                                    agent is installed:

                                                              1. Log on as root.

                                                              2. Run the following commands:

                                                                        a. cd <i3
                                                                           root>/products/i
                                                                           nsight/install

                                                                        b. ./network_root.s
                                                                           h

                                                              3. Use AdminPoint to restart the
                                                                 Insight/Network agent on the
                                                                 patched server.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS_MUAGS_710_011        Obsolete by    20-Jun-         If the patched server is
                                    patch          2005
                                    IS_MUAGS_
                                                                    Linux, the Insight OS agent
            (cont.)
                                    710_013                         is installed, and the Insight
                                    released as                     OS agent is using the Insight
                                    part of                         OS kernel module to monitor
                                    Bundle Patch
                                    BU_I3_710_
                                                                    the server:
                                    002
                                                                        1. Log on as root.

                                                                        2. Run the following
                                                                           commands:

                                                                                a. cd <i3
                                                                                   root>/prod
                                                                                   ucts/insig
                                                                                   ht/install

                                                                                b. ./psimod_u
                                                                                   ninstall.s
                                                                                   h

                                                                                c.   ./os_root.
                                                                                     sh

                                                                        3. Use AdminPoint to
                                                                           restart the Insight/OS
                                                                           agent on the patched
                                                                           server.

                                                                   If the patched server is UNIX
                                                                    and the Insight MQ agent is
                                                                    installed:

                                                              1. Stop all monitored queue
                                                                 managers.

                                                              2. Log on as mqm user.

                                                              3. Run the following commands:

                                                                        a. cd <i3
                                                                           root>/products/i
                                                                           nsight/bin

                                                                        b. cp psi_mq_exits*
                                                                           <MQ lib
                                                                           directory>
                                                                           (default:/var/mq
                                                                           m/exits)

                                                              4. Start all monitored queue
                                                                 managers.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS_MUAGS_710_011        Obsolete by    20-Jun-          If the patched server is
                                    patch          2005
                                    IS_MUAGS_
                                                                     Windows and the Insight
            (cont.)
                                    710_013                          MQ agent is installed:
                                    released as
                                    part of                      1. Start all monitored queue
                                    Bundle Patch                    managers.
                                    BU_I3_710_
                                    002
                                                             Note

                                                             This patch will stop and then restart
                                                             Indepth/Oracle FocalPoint,
                                                             Indepth/SQL Server FocalPoint,
                                                             Indepth/Web FocalPoint, and Insight
                                                             FocalPoint, if they are installed on the
                                                             patched server.

                                                             Obsolete

                                                             This patch is cumulative, and includes
                                                             all updates and fixes, released in
                                                             patches IS_MUAGS_710_008 and
                                                             IS_MUAGS_710_009 (and all of their
                                                             predecessors), making those patches
                                                             obsolete.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                 Release
  Product           Patch ID        Status                              Description
                                                  Date

 Insight    IS_ISFP_710_012       Published(b)   22-Jul-   This patch contains the following
                                  Released as    2005
                                  part of
                                                           enhancements:
                                  Bundle Patch
                                  BU_I3_710_                      SmartLink can now be
                                  002                              enabled on a Performance
                                                                   Warehouse, based on SQL
                                                                   Server (only the SQL Server
                                                                   case sensitive mode is
                                                                   supported).

                                                                  Support for Citrix monitoring.
                                                                   For more information, contact
                                                                   VERITAS Technical Support.

                                                           This patch solves the following
                                                           problems:

                                                                  Some of the grouped entities'
                                                                   performance data is not
                                                                   summed according to the
                                                                   grouping rules.

                                                                  Physical Memory for a server
                                                                   is overstated.

                                                                  Some of the cases, in which
                                                                   the following error message is
                                                                   displayed in the Insight user
                                                                   interface:

                                                                   Unable to execute a
                                                                   query.

                                                                   are solved by changes made
                                                                   in the index properties of the
                                                                   Insight Performance
                                                                   Warehouse tables that reside
                                                                   on Oracle 9 and above.

                                                           Notes

                                                           If Insight/SmartLink for Web
                                                           Applications is enabled and neither
                                                           patch IS_ISFP_710_007 nor patch
                                                           IS_ISFP_710_010 has not been
                                                           installed, you are required to restart
                                                           all monitored JVMs that belong to the
                                                           J2EE AppTier, on which
                                                           Insight/SmartLink for Web
                                                           Applications has been enabled.




                                             3
                               VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS_ISFP_710_012         Published(b)   22-Jul-   Obsolete
                                    Released as    2005
            (cont.)                 part of
                                    Bundle Patch
                                                             This patch is cumulative, and includes
                                    BU_I3_710_               all enhancements and fixes that were
                                    002                      previously released in patch
                                                             IS_ISFP_710_010 (and all of its
                                                             predecessors), therefore making that
                                                             patch obsolete.

 Insight    IS_MUAGS_710_013        Published(b)   22-Jul-   This patch is a cumulative patch that
                                    Released as    2005
                                    part of
                                                             contains enhancements and fixes
                                    Bundle Patch             problems in Insight agents for the
                                    BU_I3_710_               following AppTiers: MQ, Oracle
                                    002                      Applications, J2EE, Tuxedo, Network,
                                                             and OS.

                                                             This patch adds support for the
                                                             following:

                                                                    Support for Citrix monitoring
                                                                     For more information, contact
                                                                     VERITAS Technical Support.

                                                                    OS monitoring on Solaris 10.

                                                                     For the complete information,
                                                                     refer to the VERITAS i3
                                                                     Support Matrix.

                                                             This patch contains the following
                                                             enhancement:

                                                                    Improvements to the clarity of
                                                                     the warning and error
                                                                     messages, as written by
                                                                     Insight agents to the Insight
                                                                     log and trace files.

                                                             This patch solves the following
                                                             problems:

                                                                    Physical Memory for a server
                                                                     is overstated.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                             Description
                                                    Date

 Insight    IS_MUAGS_710_013        Published(b)   22-Jul-         Insight FocalPoint fails during
                                    Released as    2005
                                    part of
                                                                    the loading of OS
            (cont.)
                                    Bundle Patch                    performance data, due to
                                    BU_I3_710_                      problems in the Insight/OS
                                    002                             agent on Windows servers,
                                                                    while monitoring processes
                                                                    with non-English characters
                                                                    in their user names.

                                                                    The following error message
                                                                    is written to the Insight
                                                                    FocalPoint log file:

                                                                    ID : SEVERE-3010229
                                                                    Msg : An error
                                                                    occurred in the
                                                                    Insight FocalPoint
                                                                    Loader thread.

                                                                   Missing Network data for
                                                                    servers with more than 16 IP
                                                                    addresses.

                                                                    The following warning
                                                                    message is written to the log
                                                                    file:

                                                                    ID : WARNING-3000086
                                                                    Msg : IP address
                                                                    associated to port
                                                                    9745 exceeds maximum
                                                                    16. Set the
                                                                    configuration variable
                                                                    max_ips4port_no.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS_MUAGS_710_013        Published(b)   22-Jul-         The Insight/MQ API exit fails
                                    Released as    2005
                                    part of
                                                                    to be loaded in Solaris
            (cont.)
                                    Bundle Patch                    servers and causes
                                    BU_I3_710_                      problems, while trying to
                                    002                             connect to the queue
                                                                    manager.

                                                                    The following error message
                                                                    is written to the WebSphere
                                                                    MQ error file:

                                                                    AMQ7214: The module
                                                                    for API Exit
                                                                    'VeritasI3Agent' could
                                                                    not be loaded.
                                                                    EXPLANATION:
                                                                    The module
                                                                    '/var/mqm/exits/psi_mq
                                                                    _exits' for API Exit
                                                                    'VeritasI3Agent' could
                                                                    not be loaded for
                                                                    reason
                                                                    xecU_S_LOAD_FAILED.

                                                                   Missing Network data for
                                                                    Windows servers when
                                                                    Insight Network dynamic
                                                                    ports monitoring is enabled.

                                                                    The following error message
                                                                    is written to the log file:

                                                                    ID : SEVERE-3000011
                                                                    Msg : Failed to open
                                                                    device driver all.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS_MUAGS_710_013        Published(b)   22-Jul-   Important
                                    Released as    2005
            (cont.)                 part of
                                    Bundle Patch
                                                             The post-installation action items are
                                    BU_I3_710_               displayed according to the installed
                                    002                      Insight agents on the patched server.
                                                             The following list is an overview of the
                                                             action items that are required to be
                                                             performed for the different
                                                             configurations.

                                                                    If the patched server is AIX
                                                                     and the Insight Network
                                                                     agent is installed:
                                                                         5. Log on as root.
                                                                         6. Run the following
                                                                            commands:

                                                                                  a. cd <i3
                                                                                     root>/prod
                                                                                     ucts/insig
                                                                                     ht/<local
                                                                                     server
                                                                                     name>/kern
                                                                                     el

                                                                                  b. ./uninstal
                                                                                     l_drv.sh

                                                                                  c.   cd <i3
                                                                                       root>/prod
                                                                                       ucts/insig
                                                                                       ht/install

                                                                                  d. ./network_
                                                                                     root.sh
                                                                         7. Use AdminPoint to
                                                                            restart the
                                                                            Insight/Network agent
                                                                            on the patched
                                                                            server.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS_MUAGS_710_013        Published(b)   22-Jul-         If the patched server is Sun
                                    Released as    2005
                                    part of
                                                                    or AIX and the Insight OS
            (cont.)
                                    Bundle Patch                    agent is installed:
                                    BU_I3_710_
                                    002                                 2. Log on as root.

                                                                        3. Run the following
                                                                           commands:

                                                                                a. cd <i3
                                                                                   root>/prod
                                                                                   ucts/insig
                                                                                   ht/install

                                                                                b. ./os_root.
                                                                                   sh

                                                                        4. Use AdminPoint to
                                                                           restart the Insight/OS
                                                                           agent on the patched
                                                                           server.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                            Description
                                                    Date

 Insight    IS_MUAGS_710_013        Published(b)   22-Jul-         If the patched server is Linux
                                    Released as    2005
                                    part of
                                                                    and the Insight Network
            (cont.)
                                    Bundle Patch                    agent is installed:
                                    BU_I3_710_
                                    002                                 1. Log on as root.
                                                                        2. Run the following
                                                                           commands:

                                                                                o   cd <i3
                                                                                    root>/prod
                                                                                    ucts/insig
                                                                                    ht/install

                                                                                o   ./network_
                                                                                    root.sh
                                                                        3. Use AdminPoint to
                                                                            restart the
                                                                            Insight/Network agent
                                                                            on the patched
                                                                            server.


                                                                   If the patched server is
                                                                    Linux, the Insight OS agent
                                                                    is installed, and the Insight
                                                                    OS agent is using the Insight
                                                                    OS kernel module to monitor
                                                                    the server:

                                                                        1. Log on as root.

                                                                        2. Run the following
                                                                           commands:

                                                                                o   cd <i3
                                                                                    root>/prod
                                                                                    ucts/insig
                                                                                    ht/install

                                                                                o   ./psimod_u
                                                                                    ninstall.s
                                                                                    h

                                                                                o   ./os_root.
                                                                                    sh

                                                                        3. Use AdminPoint to
                                                                           restart the Insight/OS
                                                                           agent on the patched
                                                                           server.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Insight    IS_MUAGS_710_013        Published(b)   22-Jul-          If the patched server is UNIX
                                    Released as    2005
                                    part of
                                                                     and the Insight MQ agent is
            (cont.)
                                    Bundle Patch                     installed:
                                    BU_I3_710_
                                    002                                  1. Log on as mqm user.
                                                                         2. Stop all monitored
                                                                            queue managers.

                                                                         3. Run the following
                                                                            commands:

                                                                                  o   cd <i3
                                                                                      root>/prod
                                                                                      ucts/insig
                                                                                      ht/bin

                                                                                  o   cp
                                                                                      psi_mq_exi
                                                                                      ts* <MQ
                                                                                      lib
                                                                                      directory>
                                                                                      (default:/
                                                                                      var/mqm/ex
                                                                                      its)

                                                                         4. Start all monitored
                                                                            queue managers.



                                                                    If the patched server is
                                                                     Windows and the Insight
                                                                     MQ agent is installed:
                                                                         1. Start all monitored
                                                                            queue managers.

                                                             Obsolete

                                                             This patch is cumulative, and includes
                                                             all updates and fixes, released in
                                                             patch IS_MUAGS_710_011 (and all
                                                             of its predecessors), making this
                                                             patch obsolete.

 Insight    IS_MUAGS_710_014        Published(b)   22-Jul-   This patch updates the installation kits
                                    Released as    2005
                                    part of
                                                             for Insight agents. The new
                                    Bundle Patch             installation kits will be used for all
                                    BU_I3_710_               Insight agents installed on a new
                                    002                      server.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Indepth for   OR_ORFP_710_002      Obsolete by    01-Nov-   This patch contains the following
 Oracle                             patch          2004
                                                             enhancement:
                                    OR_FPAG_7
                                    10_007                          Displays the list of statements
                                                                     in the Association area of the
                                                                     Activity workspace more
                                                                     quickly.

                                                             This patch fixes the following
                                                             problems:

                                                                    The overtime graphs in the
                                                                     Objects workspace were
                                                                     displaying information about
                                                                     changes earlier than when
                                                                     they had really occurred.

                                                                    During the warehouse
                                                                     migration of data from
                                                                     versions 6.2 and 6.2.1, SQL
                                                                     statements are not formatted.
                                                                     To overcome this problem,
                                                                     this patch adds a special
                                                                     utility that formats all
                                                                     upgraded statements that
                                                                     have not yet been formatted.
                                                                     This utility must be run after
                                                                     the upgrade is completed.
                                                                     To activate this utility run the
                                                                     following script on the
                                                                     Indepth/Oracle FocalPoint
                                                                     server:

                                                                     On UNIX:
                                                                     <i3 root
                                                                     directory>/products/or
                                                                     acle/bin/upgrade_forma
                                                                     t.sh

                                                                     On Windows:
                                                                     <i3 root
                                                                     directory>\products\or
                                                                     acle\bin\upgrade_forma
                                                                     t.bat




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date

 Indepth for   OR_ORFP_710_002         Obsolete by    01-Nov-         An explain of statements that
 Oracle                                patch          2004
               (cont.)
                                                                       contained a call to a function,
                                       OR_FPAG_7                       in their SQL statement, were
                                       10_007                          causing a core dump from the
                                                                       Performance Warehouse
                                                                       "Explain Statements"
                                                                       process. Also, the following
                                                                       error message was displayed
                                                                       in the Indepth/Oracle UI:
                                                                       "Cannot communicate with
                                                                       the server".

                                                                      Collection of data for the
                                                                       Insight/SmartLink
                                                                       correlation was activated
                                                                       even when
                                                                       Insight/SmartLink was not
                                                                       required (this meant that if
                                                                       you were NOT using the
                                                                       Insight/SmartLink you would
                                                                       have to restart your
                                                                       Indepth/Oracle Collector
                                                                       agents in order to stop this
                                                                       collection).

                                                                      Overtime graphs in the
                                                                       SmarTune workspace failed
                                                                       to display any data. Instead,
                                                                       the following message was
                                                                       displayed in place of the
                                                                       graph: "External error (1476):
                                                                       ORA-01476 divisor is equal to
                                                                       zero".




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product             Patch ID          Status                                 Description
                                                      Date

 Indepth for   OR_ORCOL_710_003       Obsolete by    01-Nov-   Affected users: All users
 Oracle                               patch          2004      This patch adds the following features:
                                                               1. Object Monitoring for Oracle version 10g
                                      OR_FPAG_7                2. Support for Indepth/Oracle Collector Agent
                                      10_007                   on RedHat Linux Advanced Server 3.0, with
                                                               Huge TLB file system
                                                               3. Support for monitoring Oracle version
                                                               10.1.0.3
                                                               4. Support for SmarTune on Oracle version 10g
                                                               (you will also need to install patch
                                                               OR_ORFP_710_002 on the Indepth/Oracle
                                                               Focal Point server in order for this feature to be
                                                               fully supported)
                                                               5. Add sampling of Statement Statistics for
                                                               Oracle version 8.1.7

                                                               This patch solves the following problems:
                                                               1. Collector on Windows that stops responding
                                                               after a while
                                                               2. Improved recognition of future problems
                                                               3. Collector sometimes not restarted after
                                                               Oracle is restarted


 Indepth for   OR_ORCOL_710_004Z      Obsolete by    05-Dec-   This patch adds support for Oracle
 Oracle                               patch          2004
                                                               10g running on Linux x86_64
                                      OR_FPAG_7                (AMD) and is relevant for all users.
                                      10_007
                                                               Requirements
                                                               Before applying this patch, make sure
                                                               to install patch OR_ORCL_710_003.




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID        Status                               Description
                                                     Date

 Indepth for   OR_ORFP_710_005      Published       3-Apr-    This patch enables the manual
 Oracle                                             2005
                                                              installation of the Indepth/Oracle
                                                              schema.

                                                              Note: The manual installation of the
                                                              Indepth/Oracle Schema is part of the
                                                                           3
                                                              VERITAS i Command Line Interface
                                                              (CLI) utility. For more information
                                                                                                  3
                                                              about implementing the VERITAS i
                                                              CLI utility in your environment,
                                                              contact VERITAS Technical Support.

                                                              Requirements:
                                                                                             3
                                                              In order to use the VERITAS i CLI
                                                              utility, you must also install the
                                                                                                 3
                                                              following patches on the VERITAS i
                                                              FocalPoint server:

                                                                     The latest cumulative
                                                                                  3
                                                                      VERITAS i user interface
                                                                      patch. At the release date of
                                                                      this patch, that is the
                                                                      UI_GUIFP_710_008 patch.

                                                                     The latest cumulative
                                                                      VERITAS i3 infrastructure
                                                                      patch. At the release date of
                                                                      this patch, that is the
                                                                      IN_INFP_710_006 patch.




                                                3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Indepth for   OR_FPAG_710_006      Obsolete by    17-Jan-   This patch enhances and fixes
 Oracle                             patch          2005
                                                             various issues regarding EMC
                                    OR_FPAG_7                storage support. It is not a cumulative
                                    10_007                   patch and therefore you must install
                                                             the following patches first:

                                                                    OR_ORFP_710_002

                                                                    OR_ORCOL_710_003 (On all
                                                                     servers which have an
                                                                     Indepth/Oracle AppTier
                                                                     installation)
                                                             This patch contains the following
                                                             enhancements:
                                                                    Adds a view called Logical
                                                                     Volume for the Oracle file in
                                                                     Objects and Activity
                                                                     workspaces. The new view is
                                                                     only available when a storage
                                                                     extension (EMC or other) is
                                                                     installed.

                                                                    Adds support for EMC Raid-5
                                                                     Devices (the new DMX
                                                                     offering).

                                                                    Displays translated Hyper
                                                                     Types (instead of numeric
                                                                     codes).

                                                                    Drill down from Hyper to EMC
                                                                     Devices will show all devices
                                                                     that are on the same Physical
                                                                     Disk as the selected Hyper.
                                                                     Currently, only devices of the
                                                                     selected Hyper are shown.
                                                             The following problems were fixed in
                                                             this patch:
                                                                    The Indepth/Oracle Collector
                                                                     agent fails to start due to a
                                                                     crash in the mapping process
                                                                     (pss_symmetrix.<symver
                                                                     >) when only Clariion units
                                                                     exist (no Symmetrix Units).




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date

 Indepth for   OR_FPAG _710_006        Obsolete by    17-Jan-         Indepth/Oracle Collector
 Oracle                                patch          2005
               (cont.)
                                                                       agents will fail to start with the
                                       OR_FPAG_7                       following error message:
                                       10_007                          SEVERE-5002200
                                                                       "Version 5.4.0-532 is
                                                                       not supported, Please
                                                                       upgrade to 5.4.2-541".
                                                                       Symapi version 5.4.0-532
                                                                       support is removed due to
                                                                       changes in Symapi
                                                                       structures.

                                                                      When a Symmetrix unit is
                                                                       connected to more than one
                                                                       server, the physical name
                                                                       column in the list of
                                                                       Symmetrix Devices in the
                                                                       Objects workspace will show
                                                                       the correct value according to
                                                                       the server of the selected
                                                                       Oracle instance. Currently,
                                                                       the physical name is
                                                                       displayed according to one of
                                                                       the connected servers
                                                                       (arbitrarily chosen).

                                                                      Fixes UI query failure due to
                                                                       duplicate rows when drilling
                                                                       to an EMC Front-End Port.
                                                                       Symptom: error 100
                                                                       (internal Indepth/Oracle
                                                                       FocalPoint error) is displayed
                                                                       in the UI and the message
                                                                       "PwRequestProcessor:po
                                                                       stProcess - details
                                                                       request got more than
                                                                       1 row, ..." is written to
                                                                       the
                                                                       logs/oracle.focal.trc
                                                                       file.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                                 Description
                                                    Date

 Indepth for   OR_FPAG_710_007      Obsolete by    31-Jan-   This patch contain various
 Oracle                             patch          2005
                                                             enhancements and problem fixes
                                    OR_FPAG_7                for the Indepth/Oracle Collector
                                    10_009                   Agent and the Indepth/Oracle
                                                             FocalPoint Agent
                                                             This patch contain all enhancements and
                                                             problems that were fixed in the following
                                                             patches therefore making them obsolete:

                                                                      OR_ORFP_710_002

                                                                      OR_ORCOL_710_003

                                                                      OR_FPAG_710_006

                                                             This patch contains the following
                                                             enhancements:

                                                                      Add support for Oracle 10g on Linux
                                                                       AMD

                                                                      Add support for Oracle 9.2.0.6 on all
                                                                       platforms (except for Linux AMD)

                                                                      Add support for AIX 5.3

                                                                      Statement statistics enable/disable
                                                                       flag was added to the Collector Agent

                                                                      Information about Read only views
                                                                       was added to the SQL Workspace

                                                                      New "Format upgraded statements"
                                                                       Utility

                                                                      Improve performance for locked
                                                                       session metric in Inform/Alerts




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date

 Indepth for   OR_FPAG_710_007         Obsolete by    31-Jan-   This patch contains fixes for the
 Oracle                                patch          2005
                                                                following problems:
               (cont.)
                                       OR_FPAG_7
                                       10_009                         Scattered and sequential I/O wait
                                                                       counters were switched

                                                                      Problem with kernel sampling in
                                                                       Linux causing the high Memory Wait
                                                                       counters to be displayed instead of
                                                                       the correct indication which is "Using
                                                                       CPU"

                                                                      The description in Extended
                                                                       Collection of some events'
                                                                       parameters was cut and displayed
                                                                       only part of its text

                                                                      Installation of Interpoint/SAP on
                                                                       Windows fails when installing using
                                                                       the the default directory (C:\Program
                                                                       Files\VERITAS Software). An error
                                                                       message appears displaying "The
                                                                       system cannot find the path
                                                                       specified" message

                                                                      Installation of Interpoint/OA on
                                                                       Windows fails when installing using
                                                                       the default directory (C:\Program
                                                                       Files\VERITAS Software). An error
                                                                       message appears displaying "The
                                                                       system cannot find the path
                                                                       specified" message

                                                                      Indepth/Oracle Collector Agent is
                                                                       crashing when the maximum number
                                                                       of sessions in Oracle is more than
                                                                       9000

                                                                      On Oracle Application environments
                                                                       with multiple languages the data
                                                                       collected by the Indepth/Oracle
                                                                       Interpoint is bogus (the text's
                                                                       language is selected randomly which
                                                                       might cause invalid data to be
                                                                       displayed)

                                                                      One of the Indepth/Oracle Collector
                                                                       Agent processes (pss_prepare)
                                                                       crashes on Oracle Application
                                                                       environment

                                                                      pss_rx was crashing intermidantly

                                                                      Drop invalid packages from the
                                                                       VERITAS schema in the monitored
                                                                       instance

                                                                      When explaining a SQL statement,
                                                                       the pss_tuner was failing on "ORA-
                                                                       1435: user does not exist" if the user
                                                                       name had lower case letters in it.



                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                               Description
                                                       Date

 Indepth for   OR_FPAG_710_007         Obsolete by    31-Jan-          Capacity Track report in
 Oracle                                patch          2005              Inform/Foresight now return correct
               (cont.)                                                  information anout partitioned tables
                                       OR_FPAG_7
                                       10_009


 Indepth for   OR_FPAG_710_008         Obsolete by    15-Apr-   This patch adds support for Siebel
 Oracle                                patch          2005
                                                                AppTier Collector agents for
                                       OR_FPAG_7                environments, in which the Siebel
                                       10_009                   Server is working with an Oracle
                                                                Database and is monitored by
                                                                Indepth/Oracle (a.k.a. Indepth/Oracle
                                                                Siebel Interpoint).

                                                                Indepth/Oracle Siebel Interpoint
                                                                extracts the Siebel identifiers from the
                                                                Siebel environment and correlates the
                                                                information with the information
                                                                collected by the Indepth/Oracle
                                                                AppTier Collector agents. The user is
                                                                able to view information based on
                                                                Siebel identifiers in the Indepth/Oracle
                                                                user interface, including the
                                                                Dashboard workspace, Current
                                                                workspace and the Activity
                                                                workspace.

                                                                Requirements:

                                                                This patch should be installed on the
                                                                server, on which the Indepth/Oracle
                                                                Collector agents are installed. The
                                                                following patches must be installed
                                                                before applying this patch:

                                                                       The latest cumulative
                                                                                   3
                                                                        VERITAS i user interface
                                                                                                 3
                                                                        patch on the VERITAS i
                                                                        FocalPoint server. At the
                                                                        release date of this patch that
                                                                        is the UI_GUIFP_710_008
                                                                        patch.

                                                                       The latest cumulative
                                                                                   3
                                                                        VERITAS i Infrastructure
                                                                                                 3
                                                                        patch on the VERITAS i
                                                                        FocalPoint server. At the
                                                                        release date of this patch that
                                                                        is the IN_INFP_710_006
                                                                        patch.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date

 Indepth for   OR_FPAG_710_008         Obsolete by    15-Apr-          The latest cumulative
 Oracle                                patch          2005                          3
               (cont.)
                                                                        VERITAS i Listener agent
                                                                                                  3
                                       OR_FPAG_7                        patch on the VERITAS i
                                       10_009                           FocalPoint server and all the
                                                                        servers, on which the
                                                                        Indepth/Oracle Collector
                                                                        agents are installed and
                                                                        monitoring the Siebel
                                                                        databases. At the release
                                                                        date of this patch that is the
                                                                        IN_INBA_710_007 patch.

                                                                       The latest cumulative
                                                                        VERITAS/Indepth for Oracle
                                                                        patch on the servers, on
                                                                        which the Indepth/Oracle
                                                                        Collector agents are installed.
                                                                        At the release date of this
                                                                        patch that is the
                                                                        OR_FPAG_710_007 patch.

                                                                Note:

                                                                During the application of this patch,
                                                                you will be given a list of all servers,
                                                                on which the Indepth/Oracle Collector
                                                                agents are installed (regardless what
                                                                database they are monitoring). Click
                                                                Deselect All, and then only select the
                                                                servers, on which the Indepth/Oracle
                                                                Collector agents are monitoring the
                                                                Siebel databases.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID         Status                              Description
                                                     Date

 Indepth for   OR_FPAGS_710_009      Obsolete by    23-May-   This patch is a cumulative patch that
 Oracle                              patches        2005
                                     OR_ORFP_7
                                                              contains all enhancements and
                                     10_010,                  problem fixes from previously
                                     OR_ORCOL                 released Indepth/Oracle patches.
                                     _710_011
                                     and                      It also contains solutions for the
                                     OR_ORNLS
                                     _710_012
                                                              following Indepth/Oracle Collector
                                     released as              agent and Indepth/Oracle FocalPoint
                                     part of                  agent problems:
                                     Bundle Patch
                                     BU_I3_710_                   The Index Recommendation fails,
                                     002
                                                                     providing one of the following
                                                                     errors:
                                                                      Can not communicate
                                                                      with the server.

                                                                      or

                                                                      Internal communication
                                                                      error.

                                                                  The Load Performance Data
                                                                     process fails with the
                                                                     following error message:
                                                                      An invalid XML
                                                                      character (Unicode:
                                                                      0x4) was found in the
                                                                      CDATA section.

                                                                     The Prepare process crashes
                                                                      with the following error
                                                                      message:
                                                                      Cannot Allocate
                                                                      Memory.

                                                                     A wrong Execution Count is
                                                                      shown for PL/SQL and
                                                                      Statements that retrieve no
                                                                      rows.

                                                                     The Indepth/Oracle Collector
                                                                      agent fails to start if Windows
                                                                      is not installed in its default
                                                                      directory (that is: C:\WINNT
                                                                      or C:\WINDOWS).

                                                                     The drilldown to objects from
                                                                      another entity fails when
                                                                      Interpoint is installed.




                                                3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date

 Indepth for   OR_FPAGS_710_009        Obsolete by    23-May-          The Instance Statistics
 Oracle                                patches        2005
               (cont.)                 OR_ORFP_7
                                                                        process fails with the
                                       10_010,                          following error message:
                                       OR_ORCOL
                                       _710_011
                                                                        Failed to load table
                                       and                              PW_ORDI_DISPATCH....
                                       OR_ORNLS
                                       _710_012                 Obsolete
                                       released as
                                       part of
                                       Bundle Patch             This patch is cumulative, and includes
                                       BU_I3_710_               all updates and fixes from the patches
                                       002                      OR_FPAG_710_008 and
                                                                OR_FPAG_710_007 (and all of its
                                                                predecessors), making all those
                                                                patches obsolete.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Indepth for   OR_ORFP_710_010      Published(b)   22-Jul-   This patch contains various
 Oracle                             Released as    2005
                                    part of
                                                             enhancements and problem fixes for
                                    Bundle Patch             the Indepth/Oracle FocalPoint agent.
                                    BU_I3_710_
                                    002                      This patch adds the following features
                                                             and enhancements:

                                                                    Display Control files and
                                                                     Redo Log files in the Objects
                                                                     workspace, with the option to
                                                                     drill for those files to Storage
                                                                     Devices.

                                                                    Performance improvements
                                                                     in the response time of the
                                                                     Dashboard and Activity
                                                                     workspaces.

                                                                    Support for the new
                                                                     NLS_CHARACTERSET that
                                                                     was introduced in Oracle
                                                                     version 9.

                                                             This patch solves the following
                                                             problems:

                                                                    "Table Lock Wait" time is not
                                                                     summed into the "Application
                                                                     Lock Wait" time in the Objects
                                                                     grid in the Dashboard
                                                                     workspace and in the "In
                                                                     Oracle" view of the Object
                                                                     entity in the Activity
                                                                     workspace.

                                                                    Indepth/Oracle FocalPoint
                                                                     hangs during startup if
                                                                               3
                                                                     VERITAS i FocalPoint is
                                                                     down.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date

 Indepth for   OR_ORFP_710_010         Published(b)   22-Jul-         The Performance Warehouse
 Oracle                                Released as    2005
                                       part of
                                                                       "Collect Instance Statistics"
               (cont.)
                                       Bundle Patch                    process was wrongly
                                       BU_I3_710_                      collecting its statistics with a
                                       002                             shift of one hour. For
                                                                       example: over time graphs in
                                                                       the Statistics workspace and
                                                                       in the Statistics tab of the
                                                                       Dashboard workspace are
                                                                       displayed in a one hour shift,
                                                                       which means that the
                                                                       activities performed between
                                                                       7 am and 8 am are displayed
                                                                       as being performed between
                                                                       8 am and 9 am.

                                                                      The Explain function fails
                                                                       when accessing a table with
                                                                       more than 255 columns. In
                                                                       case the user activates the
                                                                       "Explain" function from the
                                                                       SQL workspace, the following
                                                                       error message is displayed:

                                                                       Can not communicate
                                                                       with the server.

                                                                       In case the "Explain
                                                                       Statements" process
                                                                       experiences the same
                                                                       problem, the "pss_tuner"
                                                                       process crashes and an error
                                                                       indication is shown in the
                                                                       "Status" process and in the
                                                                       "Run history" process.

                                                                      The Recommend function
                                                                       fails when trying to
                                                                       recommend hints. The
                                                                       "pss_tuner" process crashes
                                                                       and the user interface
                                                                       displays the following error
                                                                       message:

                                                                       Can not communicate
                                                                       with the server.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date

 Indepth for   OR_ORFP_710_010         Published(b)   22-Jul-         When Inform/Alerts is
 Oracle                                Released as    2005
                                       part of
                                                                       installed:
               (cont.)
                                       Bundle Patch
                                       BU_I3_710_                            Inform/Alert "Near
                                       002                                    Capacity Tablespace"
                                                                              metric is not reported
                                                                              when an
                                                                              autoextend
                                                                              tablespace
                                                                              reaches its maxsize.

                                                                             Slow performance
                                                                              and a huge CPU
                                                                              resource
                                                                              consumption for
                                                                              sampling the "Locked
                                                                              Sessions" metric.

                                                                      When IBM ESS Storage
                                                                       Extension is installed:

                                                                             The "Load
                                                                              Performance Data"
                                                                              process fails loading
                                                                              the
                                                                              PS_ORDV_DEVICE_D
                                                                              ETAILS table. The
                                                                              following error
                                                                              message:

                                                                              Received
                                                                              unexpected value
                                                                              (Y) when
                                                                              expecting type
                                                                              LONG for column
                                                                              ORDV_SHRK_SHARED
                                                                              _IND

                                                                              is written to the
                                                                              logs/pw.fp.trc
                                                                              file in the
                                                                              Performance
                                                                              Warehouse
                                                                              FocalPoint server.

                                                                             The string "N/A" is
                                                                              linked to the device
                                                                              name of all IBM ESS
                                                                              devices in the Activity
                                                                              and Objects
                                                                              workspaces.

                                                                          


                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date

 Indepth for   OR_ORFP_710_010         Published(b)   22-Jul-                  Clicking the
 Oracle                                Released as    2005
                                       part of
                                                                                "Dictionary" view of
               (cont.)
                                       Bundle Patch                             the IBM ESS Device
                                       BU_I3_710_                               entity in the Activity
                                       002                                      and Objects
                                                                                workspaces results in
                                                                                an error message:

                                                                                Internal
                                                                                Indepth/Oracle
                                                                                FocalPoint
                                                                                error.

                                                                               The "Dictionary" view
                                                                                of the IBM ESS
                                                                                Device entity is
                                                                                wrongly called
                                                                                "Dictionary". It is now
                                                                                called "Storage".

                                                                       SmarTune issues:

                                                                               The SmarTune
                                                                                "Analyze Changes"
                                                                                and "Analyze
                                                                                Database Behavior"
                                                                                processes consume
                                                                                a high amount of
                                                                                CPU resources due
                                                                                to some incorrect
                                                                                internal logic.

                                                                               Whenever the "Too
                                                                                much parallel
                                                                                executions"
                                                                                problem is reported
                                                                                by SmarTune, the
                                                                                same problem is
                                                                                reported twice.

                                                                Obsolete

                                                                This patch is cumulative, and includes
                                                                all enhancements and fixes that were
                                                                previously released in all VERITAS
                                                                Indepth/Oracle FocalPoint patches,
                                                                making those patches obsolete.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID         Status                              Description
                                                     Date

 Indepth for   OR_ORCOL_710_011      Published(b)   22-Jul-   This patch contains various
 Oracle                              Released as    2005
                                     part of
                                                              enhancements and problem fixes for
                                     Bundle Patch             the Indepth/Oracle Collector agent.
                                     BU_I3_710_
                                     002                      This patch adds the following Storage
                                                              Extension related features:

                                                                     Support for QuickIO on EMC
                                                                      storage units.

                                                              This patch solves the following
                                                              problems:

                                                                     The Indepth/Oracle Collector
                                                                      agent ("pss_prepare"
                                                                      process) fails to start. The
                                                                      following error message is
                                                                      logged into the
                                                                      oracle.collector.log
                                                                      file:

                                                                      sqlText file is
                                                                      garbled.

                                                                      The patch only prevents
                                                                      future occurences of the
                                                                      problem. If you already
                                                                      experience the problem, do
                                                                      the following:

                                                                      1. Stop the Indepth/Oracle
                                                                         Collector agent.

                                                                      2. Delete the <i3
                                                                         root>/products/orac
                                                                         le/<SID>/data/sqlTe
                                                                         xt.* files (for the
                                                                         Windows platform, use a
                                                                         "\" instead of the "/").

                                                                      3. Start the Indepth/Oracle
                                                                         Collector agent.




                                                3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date

 Indepth for   OR_ORCOL_710_011        Published(b)   22-Jul-          The Indepth/Oracle Collector
 Oracle                                Released as    2005
                                       part of
                                                                        agent ("pss_prepare"
               (cont.)
                                       Bundle Patch                     process) crashes on
                                       BU_I3_710_                       Japanese installations when
                                       002                              the character set type of the
                                                                        monitored Oracle instance is
                                                                        "EUC".

                                                                       When a server is installed
                                                                        using its IP address, clicking
                                                                        Log in AdminPoint returns
                                                                        empty lists of log files for the
                                                                        Indepth/Oracle Collector
                                                                        agent.

                                                                       The "Oracle Alert Log" metric
                                                                        shows an error message
                                                                        when Oracle is down. The
                                                                        following error is written to the
                                                                        Indepth/Oracle and
                                                                        Inform/Alerts log and trace
                                                                        files:

                                                                        Collector was not
                                                                        started at least once
                                                                        while Oracle was up.

                                                                       The Indepth/Oracle Collector
                                                                        agent does not report the
                                                                        correct error if it fails to start,
                                                                                                 3
                                                                        when the VERITAS i
                                                                        installation user does not
                                                                        belong to the same group as
                                                                        the Oracle instance user.
                                                                        Clicking Verify in AdminPoint
                                                                        will result in the same error.

                                                                Note

                                                                If this patch is applied to a Linux
                                                                server or a server that has a Storage
                                                                Extension that is monitored by
                                                                Indepth/Oracle, you will be instructed
                                                                to execute the root.sh script in the
                                                                post-installation action items of this
                                                                patch.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date

 Indepth for   OR_ORCOL_710_011        Published(b)   22-Jul-   Obsolete
 Oracle                                Released as    2005
               (cont.)                 part of
                                       Bundle Patch
                                                                This patch is cumulative, and includes
                                       BU_I3_710_               all enhancements and fixes that were
                                       002                      previously released in all VERITAS
                                                                Indepth/Oracle Collector agent
                                                                patches, making those patches
                                                                obsolete.

 Indepth for   OR_ORNLS_710_012        Published(b)   22-Jul-   This patch contains Oracle client
 Oracle                                Released as    2005
                                       part of
                                                                libraries that are used by the
                                       Bundle Patch             Indepth/Oracle Collector agents for
                                       BU_I3_710_               the support of new
                                       002                      NLS_CHARACTERSET that were
                                                                introduced in Oracle version 9.

 Indepth for   JE-JECOL-710-001        Obsolete       10-Nov-   This patch adds support for the
 J2EE                                                 2004
                                                                correlation of J2EE data in
                                                                Insight/SmartLink by solving several
                                                                problems in the data collection
                                                                mechanism on UNIX platforms and on
                                                                systems configured for locales other
                                                                than the US (such as France or
                                                                Germany).

                                                                Note: This patch is mandatory for
                                                                Insight/SmartLink to work and display
                                                                relevant data in J2EE environments.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Indepth for   JE_FPAG_711_002      Obsolete by    31-Jan-
 J2EE                               patch          2005      This patch fixes a problem that
                                                             prevents drilling into Indepth/Oracle
                                    JE_FPAG_7
                                    11_003
                                                             from Indepth/J2EE.

                                                             Also included in this patch are fixes
                                                             for the following problems:

                                                                    The JVM ID list in the
                                                                     Indepth/J2EE user interface
                                                                     contains all J2EE instances
                                                                     ever created including those
                                                                     no longer active.

                                                                    An extra colon appears in the
                                                                     "Data Summary for" label
                                                                     on the main J2EE window in
                                                                     the Japanese localized
                                                                     version.

                                                                    Adaptive Instrumentation
                                                                     disables SmartLink (TAC)
                                                                     instrumentation and the
                                                                     Adaptive results are not
                                                                     applied correctly because of
                                                                     two problems:

                                                                             The Adaptive
                                                                              Instrumentation
                                                                              survey does not
                                                                              capture information
                                                                              about previously
                                                                              instrumented
                                                                              methods, so
                                                                              SmartLink (TAC) and
                                                                              other instrumentation
                                                                              is not retained
                                                                              correctly.

                                                                             Only one call is
                                                                              enabled within each
                                                                              method when the
                                                                              Adaptive
                                                                              Instrumentation
                                                                              results are applied to
                                                                              the running JVM (this
                                                                              particular problem is
                                                                              corrected when the
                                                                              JVM is restarted).




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date

 Indepth for   JE_FPAG_711_002         Obsolete by    31-Jan-         Duplicate sampling and
 J2EE                                  patch          2005
               (cont.)
                                                                       collecting of the same
                                       JE_FPAG_7                       application server metrics
                                       11_003                          creates unnecessary
                                                                       overhead.

                                                                      SmartLink (TAC) is not
                                                                       managing files properly if the
                                                                       Indepth/J2EE Collector is
                                                                       down:

                                                                              If the JVM comes up
                                                                               before the
                                                                               Indepth/J2EE
                                                                               Collector, the three
                                                                               SmartLink (TAC) files
                                                                               are created, but the
                                                                               jdbc.xml file is
                                                                               empty.

                                                                              If the Indepth/J2EE
                                                                               Collector goes down
                                                                               during an one
                                                                               aggregation interval
                                                                               the jdbc.xml file
                                                                               does not include the
                                                                               closing root tag. This
                                                                               causes a failure in
                                                                               the correlation of the
                                                                               SmartLink (TAC) data
                                                                               for the aggregation
                                                                               interval in question.
                                                                               No JDBC SQL
                                                                               statements will be
                                                                               shown in the
                                                                               SmartLink (TAC) user
                                                                               interface for this
                                                                               aggregation interval.

                                                                      WAS 5.1.1 JVM will not start
                                                                       when configured with
                                                                       Indepth/J2EE
                                                                       instrumentation.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date

 Indepth for   JE_FPAG_711_002         Obsolete by    31-Jan-   Notes:
 J2EE                                  patch          2005
               (cont.)                                          Even with the problems in the third
                                       JE_FPAG_7                point fixed, Adaptive Instrumentation
                                       11_003                   may continue to disable SmartLink
                                                                (TAC) and other instrumentation if the
                                                                overhead budget is set too low. A low
                                                                overhead budget may cause the
                                                                Retain and Ignore Existing
                                                                Instrumentation Policy to exhaust the
                                                                available budget, consequently
                                                                disable the required SmartLink (TAC)
                                                                instrumentation and cause
                                                                unexpected results. When this
                                                                happens, either increase the
                                                                overhead budget so the first policy
                                                                completes or disable Adaptive
                                                                Instrumentation.
                                                                By using the Instrumentation Explorer
                                                                to disable JDBC or HTTP
                                                                instrumentation you may disable the
                                                                required SmartLink (TAC)
                                                                instrumentation and cause
                                                                unexpected results.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date

 Indepth for   JE_FPAG_711_003      Published(b)   11-May-   This patch is a cumulative patch of
 J2EE                               Released as    2005
                                    part of
                                                             Indepth/J2EE and contains all the
                                    Bundle Patch             enhancements and fixes previously
                                    BU_I3_710_               released in patch
                                    002                      JE_FPAG_711_002. The patch also
                                                             contains the following additional new
                                                             features and enhancements:

                                                                    A new and enhanced user
                                                                     interface for configuring the
                                                                     collection and display of
                                                                     Application Server Metrics in
                                                                     the Statistics Workspace.

                                                                    Support for monitoring 64-bit
                                                                     JVMs on the Sun Solaris
                                                                     platform.

                                                                    Support for the Indepth/J2EE
                                                                     FocalPoint on Windows XP
                                                                     Service Pack 2 (SP2).

                                                                    Support for multiple
                                                                     Indepth/J2EE FocalPoint
                                                                     installations on the same
                                                                     server (via the Multiple
                                                                     Listeners Unique ID in the
                                                                     Agent Installer).

                                                                    Performance improvements
                                                                     of Application Server Metrics
                                                                     on WebLogic Application
                                                                     Servers.

                                                                    A new Adaptive
                                                                     Instrumentation policy to
                                                                     reduce Survey
                                                                     Instrumentation overhead,
                                                                     resulting in a better
                                                                     application performance,
                                                                     while instrumenting with
                                                                     Indepth/J2EE.

                                                                    A new Adaptive
                                                                     Instrumentation policy to
                                                                     automatically ignore
                                                                     Sleep/Wait calls, resulting in
                                                                     a better visibility in active
                                                                     parts of the customer's
                                                                     application.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date

 Indepth for   JE_FPAG_711_003         Published(b)   11-May-          Support for App Launcher
 J2EE                                  Released as    2005
               (cont.)                 part of
                                                                        (APL) and Application Server
                                       Bundle Patch                     Metrics for WebLogic running
                                       BU_I3_710_                       with JRockit.
                                       002
                                                                       The Indepth/J2EE Collector
                                                                        agent configuration can be
                                                                        changed without the need to
                                                                        restart the Collector
                                                                        afterwards.

                                                                Also included in this patch are fixes
                                                                for the following issues:

                                                                       1504: Preserve line numbers
                                                                        in instrumented Java stack
                                                                        traces (if your application
                                                                        server generates an
                                                                        exception, instrumented
                                                                        classes will not contain
                                                                        source code line numbers in
                                                                        the stack trace).

                                                                       1501: Classes are being aged
                                                                        out of the system before they
                                                                        are used, causing gaps in the
                                                                        instrumentation (expected
                                                                        instrumentation data does not
                                                                        show up in the Indepth/J2EE
                                                                        user interface).

                                                                       1511: Instrumentation
                                                                        Explorer data caching issues
                                                                        (under some circumstances,
                                                                        the cache is not cleared
                                                                        completely, resulting in the
                                                                        display of out of date data).

                                                                       1540: The J2EE XSL
                                                                        Transformation user interface
                                                                        generates errors on AIX
                                                                        FocalPoint installations.

                                                                       1554: A user interface input
                                                                        validation issue in the time-
                                                                        chooser dialog box, when
                                                                        entering incomplete dates,
                                                                        results in the display of a
                                                                        blank screen without an error
                                                                        message.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date

 Indepth for   JE_FPAG_711_003         Published(b)   11-May-         1587: A file handle leak (in
 J2EE                                  Released as    2005
               (cont.)                 part of
                                                                       rare cases, depending on the
                                       Bundle Patch                    Application Server
                                       BU_I3_710_                      configuration, causes JBoss
                                       002                             to run out of file handles,
                                                                       eventually stopping the
                                                                       Application Server).

                                                                      The JVM ID list in the
                                                                       Indepth/J2EE user interface
                                                                       contains all J2EE instances
                                                                       ever created, including those
                                                                       no longer active.

                                                                      An extra colon appears in the
                                                                       "Data Summary for" label
                                                                       on the main J2EE window, in
                                                                       the Japanese localization.

                                                                      WAS 5.1.1 JVM will not start
                                                                       when configured with the
                                                                       Indepth/J2EE
                                                                       instrumentation.

                                                                      The previous J2EE
                                                                       Dashboard security certificate
                                                                       has expired, which can result
                                                                       in security warnings being
                                                                       issued by the user's browser.

                                                                      Unnecessary overhead due
                                                                       to duplicate sampling and the
                                                                       collection of identical App
                                                                       Server Metrics.

                                                                The following SmartLink (TAC) issues
                                                                are also fixed in this patch:

                                                                      1556: SmartLink (TAC) files
                                                                       created by Indepth/J2EE for
                                                                       the Insight SmartLink
                                                                       correlation, were not created
                                                                       using UTF-8 encoding (when
                                                                       running on a system, using a
                                                                       different default encoding,
                                                                       causes Insight to fail, while
                                                                       reading these files, resulting
                                                                       in missing data in SmartLink).




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date

 Indepth for   JE_FPAG_711_003         Published(b)   11-May-         Adaptive Instrumentation
 J2EE                                  Released as    2005
               (cont.)                 part of
                                                                       disables the SmartLink
                                       Bundle Patch                    (TAC) instrumentation and
                                       BU_I3_710_                      the Adaptive results are not
                                       002                             applied correctly under
                                                                       certain circumstances.
                                                                       Adaptive Instrumentation
                                                                       does not properly retain
                                                                       previously existing
                                                                       instrumentation, so SmartLink
                                                                       (TAC) and other
                                                                       instrumentation is not
                                                                       retained correctly.
                                                                       Additionally, only one call is
                                                                       enabled within each method,
                                                                       when the Adaptive
                                                                       Instrumentation results are
                                                                       applied to the running JVM
                                                                       (this particular problem is
                                                                       corrected when the JVM is
                                                                       restarted).
                                                                       Note:

                                                                       Adaptive Instrumentation may
                                                                       continue to disable SmartLink
                                                                       (TAC) and other
                                                                       instrumentation if the
                                                                       overhead budget is set too
                                                                       low (if there is not enough
                                                                       budget to instrument the
                                                                       methods TAC requires).
                                                                       When this happens, you
                                                                       should either increase the
                                                                       overhead budget, or disable
                                                                       Adaptive Instrumentation.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date

 Indepth for   JE_FPAG_711_003         Published(b)   11-May-          Under certain circumstances,
 J2EE                                  Released as    2005
               (cont.)                 part of
                                                                        JDBC SQL statements are
                                       Bundle Patch                     not shown in the SmartLink
                                       BU_I3_710_                       (TAC) user interface for this
                                       002                              aggregation interval. If the
                                                                        JVM comes up before the
                                                                        Indepth/J2EE Collector, the
                                                                        three SmartLink (TAC) files
                                                                        are created, but the
                                                                        jdbc.xml file is empty. If the
                                                                        Indepth/J2EE Collector goes
                                                                        down during one aggregation
                                                                        interval, the jdbc.xml file
                                                                        does not include the closing
                                                                        root tag. This causes a failure
                                                                        in the correlation of the
                                                                        SmartLink (TAC) data, for the
                                                                        aggregation interval in
                                                                        question.

                                                                Obsolete:

                                                                This patch is cumulative, and includes
                                                                all updates and fixes from patch
                                                                JE_FPAG_711_002, making that
                                                                patch obsolete.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product            Patch ID         Status                              Description
                                                    Date
 Indepth for
               WW_WWFP_710_001      Obsolete by    16-Feb-   This patch contains the following
 Web
                                    patch          2005
                                                             enhancement:
                                    WW_FPAGS
                                    _710_004                        Availability to sample web
                                                                     sites that can not be reached
                                    which was                        by server name.
                                    published as
                                    part of
                                                                     After installing the patch, you
                                    Bundle Patch                     will be able to monitor the
                                    BU_I3_710_                       server by mapping its IP
                                    001                              address and its server name
                                                                     by adding an instance entry
                                                                     to the following file (The file
                                                                     resides on the server, on
                                                                     which your Indepth/Web
                                                                     FocalPoint is installed.):

                                                                     Windows:
                                                                     <i3_root>\products\www
                                                                     \focalpoint\dataloader
                                                                     \resources\
                                                                     availability_mapping.x
                                                                     ml

                                                                     UNIX:
                                                                     <i3_root>/products/www
                                                                     /focalpoint/dataloader
                                                                     /resources/
                                                                     availability_mapping.x
                                                                     ml

                                                                     Example:
                                                                     <instance>
                                                                     <server-
                                                                     name>10.10.1.24</server-
                                                                     name>
                                                                     <port>80</port>
                                                                     <alias>The_name_of_the_ser
                                                                     ver_as_in_i3</alias>
                                                                     </instance>




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date
 Indepth for
               WW_WWFP_710_001         Obsolete by    16-Feb-   This patch solves the following
 Web
                                       patch          2005
               (Cont.)
                                                                problems:
                                       WW_FPAGS
                                       _710_004                        Grouping synchronization
                                                                        failure.
                                       which was
                                       published as                     Symptom description
                                       part of
                                       Bundle Patch                     The following errors will be
                                       BU_I3_710_                       found in the
                                       001                              infra.i3fp.trc file (error
                                                                        code 1001100):

                                                                        Invalid column name
                                                                        'INSM_UPDATE_TIME'

                                                                        Invalid column name
                                                                        'INCE_UPDATE_TIME'

                                                                       Insight launch of Indepth/Web
                                                                        failures.
                                                                        Scenario 1
                                                                        When selecting the "Display
                                                                        by Client IPs" and "Sort by
                                                                        Alphabetically" entities in
                                                                        the web AppTier of the Insight
                                                                        user interface and then
                                                                        launching Indepth/Web, the
                                                                        following errors will be
                                                                        displayed on the Indepth/Web
                                                                        user interface:

                                                                        Internal data
                                                                        retrieval error.
                                                                        External error(904):
                                                                        ORA-00904: "NAT_NAME":
                                                                        Invalid identifier

                                                                        or

                                                                        Internal data
                                                                        retrieval error.
                                                                        External error(207):
                                                                        Invalid columns name
                                                                        'undefined'.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date
 Indepth for                                                            Scenario 2
               WW_WWFP_710_001         Obsolete by    16-Feb-
 Web
                                       patch          2005              When selecting the "Sort by
               (Cont.)                                                  Network Bytes (Avg)" entity
                                       WW_FPAGS                         in the AppTier of the Insight
                                       _710_004
                                                                        user interface and then
                                       which was                        launching Indepth/Web, the
                                       published as                     following error will be
                                       part of                          displayed on the Indepth/Web
                                       Bundle Patch
                                       BU_I3_710_                       user interface:
                                       001
                                                                        Internal data
                                                                        retrieval error.
                                                                        External error(904):
                                                                        ORA-00904:
                                                                        "UNDEFINED": Invalid
                                                                        identifier

                                                                       Returning warning message
                                                                        about a retrieval failure of the
                                                                        instance filter parameters.
                                                                        Symptom description
                                                                        The error "Error getting
                                                                        process parameters"
                                                                        (error code 6510043)
                                                                        will be found in the
                                                                        web.dataloader.log file.

                                                                       Warehouse migration of an
                                                                        Indepth/Web instance from a
                                                                                   3
                                                                        VERITAS i 6.x instance does
                                                                        not display the correct
                                                                        amount of "Total Rows".

                                                                Note: During the installation of the
                                                                patch, the Performance Warehouse
                                                                and Indepth/Web FocalPoint agents
                                                                will be stopped and then restarted
                                                                automatically.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product            Patch ID          Status                              Description
                                                     Date
 Indepth for
               WW_WWAGS_710_002      Obsolete by    16-Feb-   This patch solves the following
 Web
                                     patch          2005
                                                              problems:
                                     WW_FPAGS
                                     _710_004                        No data is collected by the
                                                                      Indepth for Web Server agent
                                     which was                        for WebLogic installations,
                                     published as
                                     part of
                                                                      due to white spaces in the
                                     Bundle Patch                     <i3 root> directory path.
                                     BU_I3_710_                       The following errors will be
                                     001                              shown in the WebLogic
                                                                      output:
                                                                      java.lang.UnsatisfiedL
                                                                      inkError: Can't load
                                                                      library:
                                                                      [i3
                                                                      root]\products\www\fil
                                                                      ter\bin\pssFilterWL.dl
                                                                      l

                                                                     The IVP verification
                                                                      incorrectly reports that the
                                                                      server is down when the http
                                                                      response is 403 (Forbidden).

                                                                     The instance statistics slice
                                                                      times, reports the slice end
                                                                      time as the slice start time,
                                                                      making statistics available on
                                                                      the Statistics Workspace
                                                                      before the time slice has
                                                                      actually ended. The problem
                                                                      occurs when monitoring the
                                                                      IIS Web Server.

                                                                     Apache permission problem
                                                                      workaround - Adds the ability
                                                                      to insert a path that indicates
                                                                      a new location for the
                                                                      pss_startline and
                                                                      pss_restart files.




                                                3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
 Web
               WW_WWAGS_710_002        Obsolete by    16-Feb-         Deleted instances are not
                                       patch          2005
               (Cont.)
                                                                       removed from the
                                       WW_FPAGS                        instance.cfg file when
                                       _710_004                        uninstalling Web Server
                                                                       instances. If a new instance
                                       which was
                                       published as
                                                                       with the same name is
                                       part of                         installed, the instance.cfg
                                       Bundle Patch                    file will include both instance
                                       BU_I3_710_                      names, the deleted and the
                                       001
                                                                       new one. When the agent
                                                                       retrieves the instance
                                                                       information, it shows the first
                                                                       instance name in the file.

                                                                      Indepth for Web is not able to
                                                                       monitor WebLogic activity on
                                                                       Linux, due to an internal
                                                                       error.

                                                                      Failures in the IP's detection
                                                                       process (UNIX installations).
                                                                       When starting the Web
                                                                       Server agent the following
                                                                       message will pop up:

                                                                       Fail during operation:
                                                                       start the
                                                                       etc/instances.cfg file
                                                                       does not exists in
                                                                       /home/i3v7/products/ww
                                                                       w/filter!

                                                                      Inaccurate PageFaultCount
                                                                       and ProcessMemory
                                                                       counters for IPlanet Web
                                                                       Server installations, due to
                                                                       statistic input files that include
                                                                       duplicate counters.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product            Patch ID          Status                               Description
                                                     Date
 Indepth for
               WW_WWAGS_710_003      Obsolete by    16-Feb-   This patch contains the following
 Web
                                     patch          2005
                                                              enhancements:
                                     WW_FPAGS
                                     _710_004                         Support for installing Indepth
                                                                       for Web AppTier Collector
                                     which was                         agents for monitoring
                                     published as
                                     part of
                                                                       WebLogic 8.1.
                                     Bundle Patch
                                     BU_I3_710_                        Note: Instance statistics is
                                     001                               not supported for the version

                                                                      Support for installing Indepth
                                                                       for Web AppTier Collector
                                                                       agents for monitoring IIS 6.

                                                                      Adds new automatic
                                                                       installation support for
                                                                       PeopleSoft instrumentation.

                                                                      Adds a specific message for
                                                                       notification of unsupported
                                                                       PeopleSoft environments.
                                                                       The following message is
                                                                       displayed when installing
                                                                       PeopleSoft and its
                                                                       configuration signature
                                                                       (checksum) is not supported:
                                                              The PeopleSoft configuration
                                                              does not match the Indepth
                                                              for Web automatic
                                                              installation. Please contact
                                                              VERITAS support.

                                                              Notes:

                                                                      This patch must be installed
                                                                       before installing the Indepth
                                                                       for Web AppTier for
                                                                       monitoring the IIS 6 or the
                                                                       WebLogic 8.1 (you will be
                                                                       able to choose any of the
                                                                                   3
                                                                       VERITAS i servers that you
                                                                       installed).

                                                                      Patch WW_WWAGS_710_003
                                                                       also includes all the fixes that
                                                                       were released in patch
                                                                       WW_WWAGS_710_002 and
                                                                       therefore can be used in
                                                                       environments that combine
                                                                       both technologies supported
                                                                       by this patch and other
                                                                       technologies that require the
                                                                       fixes released in patch
                                                3
                                                                       WW_WWAGS_710_002.
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date
 Indepth for
               WW_WWAGS_710_003        Obsolete by    16-Feb-   Important warning:
 Web
                                       patch          2005
               (Cont.)
                                       WW_FPAGS                        When installing the patch on
                                       _710_004                         the target server, if the
                                                                        following message is
                                       which was                        displayed, you should choose
                                       published as
                                       part of
                                                                        the option "Yes to All":
                                       Bundle Patch             The file <FILE NAME> already
                                       BU_I3_710_
                                       001
                                                                exists on the remote server
                                                                <SERVER NAME> and its size
                                                                is different (Target file
                                                                size on the remote server
                                                                is: <SIZE> Source file size
                                                                is: <SIZE>). Would you like
                                                                to replace the existing file
                                                                with the updated one?

                                                                       After the patch was installed,
                                                                        when using the VERITAS i3
                                                                        Agent Installer to install a new
                                                                        Web AppTier, the following
                                                                        message is displayed, you
                                                                        should choose the option "No
                                                                        to All":
                                                                The file <FILE NAME> already
                                                                exists on the remote server
                                                                <SERVER NAME> and its size
                                                                is different (Target file
                                                                size on the remote server
                                                                is: SIZE Source file size
                                                                is: SIZE). Would you like to
                                                                replace the existing file
                                                                with the updated one?

                                                                Important: After installing this patch,
                                                                there are specific post installation
                                                                action items that need to be
                                                                performed, when installing Indepth for
                                                                Web AppTier Collector agents for
                                                                WebLogic 8.1. Perform the normal
                                                                installation of the Indepth for Web
                                                                AppTier (type: WebLogic), but
                                                                disregarding the post installation
                                                                action items. Instead use the following
                                                                post installation actions:




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
               WW_WWAGS_710_003        Obsolete by    16-Feb-   In WebLogic Builder:
 Web
                                       patch          2005
               (Cont.)
                                       WW_FPAGS
                                                                   1. Go to File --> Open. The
                                       _710_004                       "Open an exploded or
                                                                      archived module" dialog box
                                       which was                      opens.
                                       published as
                                       part of
                                       Bundle Patch
                                                                   2. Browse to the relevant
                                       BU_I3_710_                     archived file or exploded
                                       001                            directory and click on Open.

                                                                   3. Repeat steps 1 and 2 for
                                                                      each archived file or exploded
                                                                      directory that is part of the
                                                                      application.

                                                                   4. To add a filter definition,
                                                                      perform the following steps
                                                                      for each sub application:

                                                                           a. On the tree, expand
                                                                              each sub application
                                                                              and select Filters.

                                                                           b. In the Filters panel,
                                                                              click Add. A dialog
                                                                              box opens.

                                                                           c.   On the General tab,
                                                                                type pssFilter into
                                                                                the Filter name field.

                                                                           d. In the Filter class
                                                                              field, type
                                                                              com.precise.ifwe
                                                                              b.Collection.Fil
                                                                              ters.pssFilter.W
                                                                              LFilter

                                                                                        Note: The
                                                                                        Filter class is
                                                                                        case
                                                                                        sensitive.
                                                                                        Make sure to
                                                                                        use the
                                                                                        correct case.

                                                                           e. Click the Display
                                                                              name tab.

                                                                           f.   In the Display name
                                                                                field, type Veritas
                                                                                Indepth for Web
                                                                                Web Filter.


                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                          Description
                                                       Date
 Indepth for
               WW_WWAGS_710_003        Obsolete by    16-Feb-           g. Browse to the
 Web
                                       patch          2005
               (Cont.)
                                                                           relevant archived file
                                       WW_FPAGS                            or exploded directory
                                       _710_004                            and click on Open.
                                       which was                 5. To add Filter Mapping,
                                       published as
                                       part of
                                                                    perform the following steps
                                       Bundle Patch                 for each sub application:
                                       BU_I3_710_
                                       001                              a. On the tree, select
                                                                           Servlet/Filter Maps.

                                                                        b. In the right panel,
                                                                           click the Filter
                                                                           Mappings tab.

                                                                        c.   Click on Add.

                                                                        d. From the Filter list,
                                                                           select pssFilter.

                                                                        e. In the URL pattern
                                                                           field, type *.

                                                                        f.   Click on OK.

                                                                 6. Save your settings and all
                                                                    files. Then close WebLogic
                                                                    Builder.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
               WW_WWAGS_710_003        Obsolete by    16-Feb-   Example for the procedure in the
 Web
                                       patch          2005
               (Cont.)
                                                                WebLogic Builder
                                       WW_FPAGS
                                       _710_004                       For the demo application
                                                                       "MedRec," you need to open
                                       which was                       the following files through the
                                       published as
                                       part of                         "Open an exploded or
                                       Bundle Patch                    archived mode" dialog box:
                                       BU_I3_710_
                                       001                                     ../weblogic81/sa
                                                                               mples/server/med
                                                                               rec/build/medrec
                                                                               Ear
                                                                               ../weblogic81/sa
                                                                               mples/server/med
                                                                               rec/build/physic
                                                                               ianEar
                                                                               ../weblogic81/sa
                                                                               mples/server/med
                                                                               rec/build/startu
                                                                               pEar


                                                                      Each of these files include the
                                                                       following subapplications, for
                                                                       which you need to define
                                                                       filters and add Filter Mapping:

                                                                           o   ../weblogic81/sa
                                                                               mples/server/med
                                                                               rec/build/medrec
                                                                               Ear:

                                                                               mainWebApp
                                                                               adminWebApp
                                                                               patientWebApp


                                                                           o   ../weblogic81/sa
                                                                               mples/server/med
                                                                               rec/build/physic
                                                                               ianEar:

                                                                               physicianWebApp


                                                                           o   ../weblogic81/sa
                                                                               mples/server/med
                                                                               rec/build/startu
                                                                               pEar:
                                                                               startupWebApp




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date
 Indepth for
               WW_WWAGS_710_003        Obsolete by    16-Feb-   Configuring the root application in the
 Web
                                       patch          2005
               (Cont.)
                                                                Indepth/Web filter configurations
                                       WW_FPAGS
                                       _710_004                 You must configure the root
                                                                application (that is the application that
                                       which was                serves the "/" URL). If you can not
                                       published as
                                       part of
                                                                configure the root application (for
                                       Bundle Patch             example because it does not exist),
                                       BU_I3_710_               perform the following workaround:
                                       001
                                                                    1. On the server where the
                                                                       VERITAS Indepth for Web
                                                                       Web Filter is installed, open
                                                                       the following file:
                                                                <I3_root>/products/www/filte
                                                                r/etc/ww_filter.cfg

                                                                    2. Add the following lines:

                                                                        [web-~instance_name~]
                                                                        web_site_name=~weblogi
                                                                        c_web_site_name~
                                                                        For example:
                                                                        [web-mypatstore]
                                                                        web_site_name=MyPetSto
                                                                        reWeb


                                                                    3. Restart the Web Server agent
                                                                       via AdminPoint.

                                                                Configuring the WebLogic startup
                                                                script

                                                                    1. Edit the WebLogic startup
                                                                       script by adding the following
                                                                       jar file, including its full path,
                                                                       to the CLASSPATH:

                                                                        <i3_root>\products\www
                                                                        \filter\lib\pssWLFilte
                                                                        r.jar

                                                                        Make sure to save the script
                                                                        afterwards.

                                                                    2. Restart WebLogic.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product            Patch ID          Status                              Description
                                                     Date
 Indepth for
               WW_FPAGS_710_004      Published(b)   20-Jun-   This patch contains the following
 Web
                                     Released as    2005
                                     part of
                                                              enhancements for Web AppTier
                                     Bundle Patch             monitoring:
                                     BU_I3_710_
                                     002                             Web AppTier installation
                                                                      support for entering the
                                                                      Instance name in free text
                                                                      format and enables you to
                                                                      add Instances that start with a
                                                                      digit or contain spaces in their
                                                                      names.

                                                                     Support for server-side
                                                                      monitoring of the iPlanet 4.1
                                                                      Instance Statistics.

                                                                     Support for server-side
                                                                      monitoring of the WebLogic
                                                                      8.1 Instance Statistics.

                                                                     Support for client-side
                                                                      monitoring of the Java SUN
                                                                      plug-in (Signed applet).

                                                                     Instance Statistic - support of
                                                                      SSL. Web sites that were
                                                                      configured to work in SSL
                                                                      mode only, are now fully
                                                                      supported by the statistic
                                                                      process of the server-side
                                                                      agent.

                                                              This patch solves the following
                                                              problems:

                                                                     The installation fails when the
                                                                      instance name includes
                                                                      blanks and dashes,
                                                                      displaying the following error
                                                                      message (ID 3708):

                                                              IIS logging is disabled.
                                                              Enable it.

                                                                     A read permission problem
                                                                      when installing on a
                                                                      WebLogic environment. The
                                                                      installation creates a
                                                                      VERITAS directory under the
                                                                      WebLogic root directory with
                                                                                      3
                                                                      the VERITAS i user as its
                                                                      owner and without read
                                                                      permission to the Web server
                                                                      user.

                                                3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
 Web
               WW_FPAGS_710_004        Published(b)   20-Jun-         Instrumenting empty or single
                                       Released as    2005
                                       part of
                                                                       line pages fails. The
               (Cont.)
                                       Bundle Patch                    instrumentation stops and the
                                       BU_I3_710_                      following error message is
                                       002                             displayed (Message 11334):

                                                                       One of the
                                                                       installation scripts
                                                                       failed. Click 'log' to
                                                                       view the VERITAS/i3
                                                                       FocalPoint log file.
                                                                       For additional
                                                                       information, check the
                                                                       installation log files
                                                                       on the remote server.
                                                                       If the problem
                                                                       persists, generate the
                                                                       VERITAS/i3 FocalPoint
                                                                       support file and
                                                                       contact Technical
                                                                       Support.

                                                                       The new mechanism will
                                                                       report the problematic page
                                                                       to the
                                                                       web.scriptinstaller.lo
                                                                       g file, skip it and continue
                                                                       with the instrumentation of
                                                                       the rest of the pages.

                                                                      The instrumentation stops
                                                                       when it fails to instrument a
                                                                       page. The instrumentation
                                                                       now continues, skipping the
                                                                       problematic page and
                                                                       reporting the problem to the
                                                                       instrumentation log file
                                                                       (web.scriptinstaller.l
                                                                       og).

                                                                      In instrumented PeopleSoft
                                                                       environments, the PeopleSoft
                                                                       excel reports includes invalid
                                                                       characters at the end (such
                                                                       as "');}").

                                                                      Instrumentation of ASP pages
                                                                       that have "Option explicit" in
                                                                       their contents, are causing a
                                                                       browser failure when loading
                                                                       the page.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
 Web
               WW_FPAGS_710_004        Published(b)   20-Jun-         Instance Statistics information
                                       Released as    2005
                                       part of
                                                                       is not collected - The server-
               (Cont.)
                                       Bundle Patch                    side agent is unable to
                                       BU_I3_710_                      connect to the monitored
                                       002                             Web server using the domain
                                                                       name. The following error is
                                                                       written to the
                                                                       web.instancestatistics
                                                                       .log file:

                                                                       ID : SEVERE-6530002
                                                                       Time : 2005-05-15
                                                                       07:31:47.258 GMT-00
                                                                       Thread : main (ID:
                                                                       26348010)
                                                                       Msg : Can't connect to
                                                                       webserver:
                                                                       https://mydomain:7001/
                                                                       weblogicstat.
                                                                       java.net.ConnectExcept
                                                                       ion: Connection
                                                                       refused: connect

                                                                       In order to verify the problem,
                                                                       the user may try to connect
                                                                       manually by using the direct
                                                                       URL (for example:
                                                                       https://mydomain:7001/
                                                                       weblogicstat). If the
                                                                       connection fails, but works
                                                                       when using an IP instead of
                                                                       the domain name (for
                                                                       example:
                                                                       https://2.2.2.2:7001/w
                                                                       eblogicstat), then perform
                                                                       the following "Instance
                                                                       Statistics connect by IP
                                                                       workaround".

                                                                       Instance Statistics connect by
                                                                       IP workaround:

                                                                           1. Open the following
                                                                                         3
                                                                              VERITAS i registry
                                                                              configuration file:

                                                                Windows:

                                                                <i3
                                                                root>\products\i3fp\registry
                                                                \instances\www\<server
                                                                name/ip>\<Instance-name>.xml



                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
               WW_FPAGS_710_004        Published(b)   20-Jun-                  UNIX:
 Web
                                       Released as    2005
               (Cont.)                 part of
                                       Bundle Patch
                                                                <i3
                                       BU_I3_710_               root>/products/i3fp/registry
                                       002                      /instances/www/<server
                                                                name/ip>/<Instance-name>.xml

                                                                  c.   Add a tag that contains the
                                                                       details of the Web server IP
                                                                       for the specific problematic
                                                                       instance under the root tag.
                                                                       The following is an example
                                                                       for such a tag:

                                                                               <[instance-name]>

                                                                                       <statistic-
                                                                                       ip>2.2.2.2</st
                                                                                       atistic-ip>

                                                                               </[Instance-name]>

                                                                  6. Instance Statistics information
                                                                       is not collected - The server-
                                                                       side Collector agent is unable
                                                                       to connect to the monitored
                                                                       Web server, due to the Web
                                                                       server filter mechanism.

                                                                       The following error is written
                                                                       to the
                                                                       web.instancestatistics
                                                                       .log file:

                                                                       ID : SEVERE-6530002
                                                                       Time : 2005-05-15
                                                                       07:31:47.258 GMT-00
                                                                       Thread : main (ID:
                                                                       26348010)
                                                                       Msg : Can't connect to
                                                                       webserver:
                                                                       https://mydomain:7001/
                                                                       weblogicstat.
                                                                       java.net.ConnectExcept
                                                                       ion: Connection
                                                                       refused: connect




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
               WW_FPAGS_710_004        Published(b)   20-Jun-
 Web
                                       Released as    2005       7. The statistics process (part of
               (Cont.)                 part of                         Web server Collector agent)
                                       Bundle Patch                    stops collecting data after
                                       BU_I3_710_
                                       002                             restarting the monitored Web
                                                                       server.

                                                                 8. The server-side Collector
                                                                       agent is unable to start/stop
                                                                       the filter. The HTTP request
                                                                       is blocked by the Web server.
                                                                       The following error message
                                                                       is written to the
                                                                       web.fiter.log file:

                                                                       ID : SEVERE-6560292
                                                                       Msg : No filter
                                                                       restart at any site
                                                                       under instance
                                                                       [Instance-name]

                                                                 5. The correlation mechanism
                                                                       causes the Web server to
                                                                       crash or causes situations, in
                                                                       which Web application
                                                                       sessions end abnormally.

                                                                 6. The correlation percentage
                                                                       gives poor results.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
               WW_FPAGS_710_004        Published(b)   20-Jun-
 Web
                                       Released as    2005       7. The Performance Warehouse
               (Cont.)                 part of                         Summary process fails, while
                                       Bundle Patch                    summarizing the Indepth/Web
                                       BU_I3_710_
                                       002                             server statistics table,
                                                                       inserting two exceptions in
                                                                       the Performance Warehouse
                                                                       log files (the following
                                                                       exceptions are examples):

                                                                       ID : SEVERE-2000333
                                                                       Thread : SUMMARY-
                                                                       Childs (ID: 29076847)
                                                                       Class :
                                                                       com.precise.pw.summary
                                                                       .SummarizeTable
                                                                       Method : runTask
                                                                       Msg : Unable to close
                                                                       database elements
                                                                       after exception.
                                                                       Exception : Unable to
                                                                       summarize.
                                                                       Frame : caused by:
                                                                       Unable to summarize.
                                                                       Root cause :
                                                                       java.sql.SQLException:
                                                                       ORA-01438: value
                                                                       larger than specified
                                                                       precision allows for
                                                                       this column...

                                                                       Followed by the following
                                                                       exception:

                                                                       ID : CONFIG-2050000
                                                                       Thread : SUMMARY-
                                                                       Childs (ID: 29076847)
                                                                       Class :
                                                                       com.precise.pw.summary
                                                                       .Summary
                                                                       Method :
                                                                       logErrorProperties
                                                                       Msg : Additional
                                                                       Information: {Insert
                                                                       table summary is:
                                                                       =PW_WWSC_DOMAIN_COUNTR
                                                                       Y_STATE_D,
                                                                       currentDataStartTime:=
                                                                       2005-01-07 05:00:00.0,
                                                                       now:=2005-03-12
                                                                       12:30:31.313,
                                                                       currentDataEndTime:=20
                                                                       05-01-08 04:59:59.0,
                                                                       dataEndTime:=2005-03-
                                                                       12 04:59:59.0

                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
               WW_FPAGS_710_004        Published(b)   20-Jun-
 Web
                                       Released as    2005       8. The Performance Warehouse
               (Cont.)                 part of                         Summary Data process for
                                       Bundle Patch                    Web fails, because the Web
                                       BU_I3_710_
                                       002                             availability process stores
                                                                       data in milliseconds (instead
                                                                       of seconds) in the
                                                                       WWAS_REAL_UNAVAILABI
                                                                       LITY_SUM column of the
                                                                       PW_WWAS_AVAILABILITY_
                                                                       SUMMARY_D table. This
                                                                       causes a Byte Sum field
                                                                       overflow, inserting two
                                                                       exceptions in the
                                                                       Performance Warehouse log
                                                                       files (the following exceptions
                                                                       are examples):

                                                                       ID : SEVERE-2000333
                                                                       Thread : SUMMARY-
                                                                       Childs (ID: 33136362)
                                                                       Class :
                                                                       com.precise.pw.summary
                                                                       .SummarizeTable
                                                                       Method : runTask
                                                                       Msg : Unable to close
                                                                       database elements
                                                                       after exception.
                                                                       Exception : Unable to
                                                                       summarize.
                                                                       Frame : caused by:
                                                                       Unable to summarize.
                                                                       Root cause :
                                                                       java.sql.SQLException:
                                                                       ORA-01438: value
                                                                       larger than specified
                                                                       precision allows for
                                                                       this column...




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
               WW_FPAGS_710_004        Published(b)   20-Jun-          Followed by the following
 Web
                                       Released as    2005
                                       part of
                                                                       exception:
               (Cont.)
                                       Bundle Patch
                                       BU_I3_710_                      ID : CONFIG-2050000
                                       002                             Thread : SUMMARY-
                                                                       Childs (ID: 33136362)
                                                                       Class :
                                                                       com.precise.pw.summary
                                                                       .Summary
                                                                       Method :
                                                                       logErrorProperties
                                                                       Msg : Additional
                                                                       Information: {Insert
                                                                       table summary is :
                                                                       =PW_WWAS_AVAILABILITY_
                                                                       SUMMARY_D,

                                                                 9. The Indepth/Web Load
                                                                       Performance Data process
                                                                       fails to load server-side
                                                                       performance data. The
                                                                       following error is written to the
                                                                       web.dataloader.trc file
                                                                       (the following is an example):

                                                                       ID : SEVERE-6510004
                                                                       Thread : URL (ID:
                                                                       27994366)
                                                                       Msg : Exception while
                                                                       initializing task:
                                                                       URL.
                                                                       com.precise.ifweb.infr
                                                                       a.utilities.IfwebRTExc
                                                                       eption: Broken
                                                                       constraint




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
               WW_FPAGS_710_004        Published(b)   20-Jun-
 Web
                                       Released as    2005       10. The Indepth/Web Load
               (Cont.)                 part of                         Performance Data process
                                       Bundle Patch                    fails to load server-side
                                       BU_I3_710_
                                       002                             performance data for a Web
                                                                       AppTier Instance, when the
                                                                       user changes the
                                                                       configuration of the load
                                                                       performance data parameters
                                                                       for the instance. An exception
                                                                       error is written to the
                                                                       web.dataloader.trc file
                                                                       (the following exception is an
                                                                       example):

                                                                       ID : SEVERE-6510003
                                                                       Thread : URL (ID:
                                                                       24056908)
                                                                       Class :
                                                                       com.precise.ifweb.infr
                                                                       a.utilities.loggerimp.
                                                                       I3FileLogger
                                                                       Method : trace Logger
                                                                       : web.dataloader
                                                                       Msg : Exception while
                                                                       starting task: URL.
                                                                       com.precise.ifweb.infr
                                                                       a.record.RecordRTExcep
                                                                       tion: Field
                                                                       "BitVector" not exists
                                                                       (type=3) Params : URL
                                                                       Exception : Field
                                                                       "BitVector" not exists
                                                                       (type=3) Frame :
                                                                       com.precise.ifweb.infr
                                                                       a.record.RecordRTExcep
                                                                       tion: Field
                                                                       "BitVector" not exists
                                                                       (type=3) at
                                                                       com.precise.ifweb.infr
                                                                       a.record.Catalog.getFi
                                                                       eldIndex(Catalog.java:
                                                                       193)

                                                                 11. The Dashboard table does
                                                                       not display server instances
                                                                       that do not have performance
                                                                       data for the selected time
                                                                       range.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
               WW_FPAGS_710_004        Published(b)   20-Jun-
 Web
                                       Released as    2005       12. An empty result set problem
               (Cont.)                 part of                         in the Associate with dialog -
                                       Bundle Patch                    When drilling down into URL
                                       BU_I3_710_
                                       002                             Protocols in the Associate
                                                                       with dialog (selecting More...
                                                                       in the associate of the Activity
                                                                       workspace), selecting More...
                                                                       in the Associate area and
                                                                       choosing url protocol =
                                                                       value in the Criteria tab
                                                                       (value that is part of the query
                                                                       returned values), returns an
                                                                       empty query (displaying an
                                                                       empty table).

                                                                       Note:

                                                                       The Associate with value is
                                                                       case sensitive (even after the
                                                                       patch is installed), therefore
                                                                       the user should apply values
                                                                       in the same case as they are
                                                                       stored in the database.

                                                                 13. Adding a column from the
                                                                       Table columns dialog to the
                                                                       Association area causes the
                                                                       following JavaScript error:

                                                                       A Runtime Error has
                                                                       occurred Do you wish
                                                                       to debug?
                                                                       Line : 89
                                                                       Error : '_prv' is
                                                                       undefined.

                                                                 14. The Service Time (summed)
                                                                       format is changed to be
                                                                       identical to the format in
                                                                       Insight (HH:MI:SS.TTT
                                                                       changed to HH:MI:SS).

                                                                 15. Instance parameters that are
                                                                       time-based handle the values
                                                                       as being in milliseconds, even
                                                                       though the users are
                                                                       instructed to enter values in
                                                                       seconds.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
               WW_FPAGS_710_004        Published(b)   20-Jun-   Obsolete
 Web
                                       Released as    2005
               (Cont.)                 part of
                                       Bundle Patch
                                                                This patch is cumulative, and includes
                                       BU_I3_710_               all updates and fixes from the patches
                                       002                      WW_WWAGS_710_003,
                                                                WW_WWAGS_710_002, and
                                                                WW_WWFP_710_001, making those
                                                                patches obsolete.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID         Status                              Description
                                                     Date
 Indepth for
               SQ_MUAGS_710_001      Obsolete by    15-Dec-   This patch adds support to the
 SQL Server
                                     patch          2004
                                                              following issues:
                                     SQ_
                                     FPAGS_710                       Allows the user to disable the
                                     _004                             format of statement and batch
                                                                      texts.

                                                                     Supports Format & Highlight
                                                                      for all languages.

                                                              This patch solves the following
                                                              problems:

                                                                     Filtering by SQL Text with a
                                                                      like condition results in a "No
                                                                      data found" message.

                                                                     Opening the access plan list
                                                                      in the Compare tab of SQL
                                                                      workspace for statements,
                                                                      results with an error message
                                                                      "Internal error".

                                                                     A "Cannot communicate with
                                                                      server" error message
                                                                      appears when displaying the
                                                                      locking tree in Activity
                                                                      workspace.

                                                                     Display of the locking tree, in
                                                                      Activity workspace, takes a
                                                                      long time to respond (usually
                                                                      when a long time frame is
                                                                      selected).

                                                                     COM+ Interpoint crashes
                                                                      when the server that contains
                                                                      the COM+ Components is the
                                                                      same server on which the
                                                                      SQL Server Collector Agent
                                                                      is running.
                                                                      The following error appears in
                                                                      the Event Viewer (and in the
                                                                      log/trace files):

                                                                      ID: 4502975
                                                                      Message: "The GetTable()
                                                                      method on machine
                                                                      <machine name> failed.
                                                                      Reason: An unexpected
                                                                      exception was raised"




                                                3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
 SQL Server
               SQ_MUAGS_710_001        Obsolete by    15-Dec-         The explain date reported in
                                       patch          2004
               (cont.)
                                                                       the History tab of SQL
                                       SQ_                             workspace is GMT instead of
                                       FPAGS_710                       the client local time.
                                       _004
                                                                      The "Storage", "Space over
                                                                       time" and "Rows" graphs in
                                                                       Objects workspace, don't
                                                                       display any values for periods
                                                                       in which the "Collect Space
                                                                       Usage" process did not run.

                                                                      Clicking the Tune icon on the
                                                                       list of access plans under
                                                                       Collapsed batches and
                                                                       Collapsed statements in
                                                                       Activity workspace, wrongly
                                                                       launches into the Dashboard
                                                                       workspace instead of to the
                                                                       SQL workspace.

                                                                      Not all Clariion devices are
                                                                       displayed in Objects
                                                                       workspace. Only those which
                                                                       contain SQL Server database
                                                                       files are displayed.

                                                                      SQL Server Performance
                                                                       Warehouse processes and
                                                                       the Indepth for SQL Server
                                                                       user interface fail when pan-
                                                                       European characters returned
                                                                       in error messages.

                                                                      Collector agent fails to start
                                                                       when Interpoint/Siebel and i3
                                                                       Focal Point are installed on
                                                                       the same server. The
                                                                       following error message is
                                                                       displayed in Event Viewer
                                                                       (and in the log/trace files):

                                                                       ID: 4502803
                                                                       Message: "Parameter
                                                                       pss_siebel_srvrmgr_port is
                                                                       mandatory".




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID         Status                              Description
                                                     Date
 Indepth for
               SQ_SQCOL_710_002      Obsolete by    9-Feb-    This patch adds support for SAP
 SQL Server
                                     patch          2005
                                                              AppTier Collector agents with the
                                     SQ_                      Interpoint/SAP option, enabling it to
                                     FPAGS_710                monitor a SAP 4.7 system with an
                                     _004                     SQL Server database.

                                                              Requirements:

                                                              This patch should be installed on the
                                                              server, on which the Indepth/SQL
                                                              Collector agent is installed. Before
                                                              applying this patch, install patch
                                                              SQ_MUAGS_710_001 on that server.




                                                3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product             Patch ID          Status                              Description
                                                      Date
 Indepth for
               sSQ_FPAGS_710_003      Rejected and   15-Apr-   This patch is a cumulative patch that
 SQL Server
                                      replaced by    2005
                                      patch
                                                               contains enhancements and fixes
                                                               problems for the Indepth/SQL Server
                                      SQ_                      Collector agents and the Indepth/SQL
                                      FPAGS_710                Server FocalPoint agent.
                                      _004
                                                               This patch adds the following feature:

                                                                      Support for SQL Server 2005

                                                               This patch solves the following
                                                               problems:

                                                                      Explain fails in the following
                                                                       cases:

                                                                              When the keyword
                                                                               "OUT" appears in the
                                                                               text of the SQL
                                                                               statement. Instead of
                                                                               the access plan tree,
                                                                               the following error
                                                                               message is
                                                                               displayed:

                                                                               Cannot use the
                                                                               OUTPUT option in
                                                                               a DECLARE
                                                                               statement ...

                                                                              While trying to
                                                                               "setuser" to a user
                                                                               with NT
                                                                               authentication.
                                                                               Instead of the access
                                                                               plan tree, the
                                                                               following error
                                                                               message is
                                                                               displayed:

                                                                               There is no such
                                                                               user or group
                                                                               ...




                                                 3
                                   VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
 SQL Server
               SQ_FPAGS_710_003        Rejected and   15-Apr-                 While trying to
                                       replaced by    2005
                                       patch
                                                                               calculate the access
               (cont.)
                                                                               plan hash value. The
                                       SQ_                                     following error
                                       FPAGS_710                               message is
                                       _004
                                                                               displayed:

                                                                               Invalid
                                                                               character value
                                                                               for cast
                                                                               specification

                                                                      The following Performance
                                                                       Warehouse processes ignore
                                                                       invocation parameters (as set
                                                                       in AdminPoint) and use
                                                                       default values instead:

                                                                              Collect Schema
                                                                               Changes.

                                                                              Collect Space
                                                                               Utilization.

                                                                      The Collector agent fails to
                                                                       start when the instance name
                                                                       is longer than 31 characters.

                                                                      The Collector agent
                                                                       (pssq_perf.exe) fails with the
                                                                       following error message:

                                                                       ID : SEVERE-4502990
                                                                       Msg : A PDH function
                                                                       failed. Return code: -
                                                                       2147481643

                                                                      The EMC Storage agent fails
                                                                       to start when only Clariion
                                                                       units exist (no Symmetric
                                                                       units).

                                                                      AdminPoint fails to verify the
                                                                       EMC Storage agent.

                                                                      When upgrading an SQL
                                                                       Server Instance from version
                                                                       6.5, the Performance
                                                                       Warehouse Data Migration
                                                                       utility incorrectly sets the
                                                                       working type to "COM+".




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
 SQL Server
               SQ_FPAGS_710_003        Rejected and   15-Apr-         In East Asian environments:
                                       replaced by    2005
               (cont.)                 patch
                                                                              Instance Statistics
                                       SQ_                                     are not collected for
                                       FPAGS_710                               databases with
                                       _004                                    Japanese characters
                                                                               in their name.

                                                                              Failure to associate
                                                                               to Recent Sessions
                                                                               when working in a
                                                                               Chinese
                                                                               environment. The
                                                                               following error is
                                                                               displayed on the
                                                                               Indepth/SQL Server
                                                                               user interface:

                                                                               Cannot
                                                                               communicate with
                                                                               the server

                                                                      The following user interface
                                                                       problems:

                                                                              Sorting by Index
                                                                               Keys after
                                                                               associating to
                                                                               Indexes causes an
                                                                               error. The following
                                                                               error message is
                                                                               displayed in the
                                                                               Association area:

                                                                               The ORDER BY
                                                                               position number
                                                                               61 is out of
                                                                               range ...

                                                                              Statement text is
                                                                               incorrectly formatted
                                                                               when displayed in the
                                                                               Association area grid.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date
 Indepth for
 SQL Server
               SQ_FPAGS_710_003        Rejected and   15-Apr-                  The launch from the
                                       replaced by    2005
                                       patch
                                                                                SQL workspace to
               (cont.)
                                                                                the Objects
                                       SQ_                                      workspace with a
                                       FPAGS_710                                temporary table
                                       _004
                                                                                causes an error. The
                                                                                following error
                                                                                message is
                                                                                displayed:

                                                                                table-database-
                                                                                name column
                                                                                missing from xml
                                                                                request

                                                                               The Recommend tab
                                                                                in the SQL
                                                                                Workspace fails to
                                                                                highlight the correct
                                                                                column when its
                                                                                name is similar to the
                                                                                suffix of another
                                                                                column.

                                                                       The Last Explained (Date-
                                                                        Time) column is not updated
                                                                        when the access plan is not
                                                                        changed.

                                                                       The Statement Cost, as
                                                                        displayed in the Activity
                                                                        workspace, is wrong, if the
                                                                        same statement is executed
                                                                        by different Logins, from
                                                                        different Machines, or by
                                                                        different Programs.

                                                                Requirements

                                                                Before installing this patch, you must
                                                                install the latest cumulative VERITAS
                                                                 3
                                                                i user interface patch. At the release
                                                                date of this patch, that is the
                                                                UI_GUIFP_710_008 patch.

                                                                Obsolete

                                                                This patch is cumulative, and includes
                                                                all updates and fixes from the patches
                                                                SQ_MUAGS_710_001 and
                                                                SQ_SQCOL_710_002, making those
                                                                patches obsolete.



                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                    Release
  Product             Patch ID         Status                              Description
                                                     Date
 Indepth for
               SQ_FPAGS_710_004      Published(b)   25-Apr-   This patch is a cumulative patch that
 SQL Server
                                     Released as    2005
                                     part of
                                                              contains enhancements and fixes
                                     Bundle Patch             problems for the Indepth/SQL Server
                                     BU_I3_710_               Collector agents and the Indepth/SQL
                                     002                      Server FocalPoint agent.

                                                              This patch adds the following feature:

                                                                     Support for SQL Server 2005

                                                              This patch solves the following
                                                              problems:

                                                                     Explain fails in the following
                                                                      cases:

                                                                          o   When the keyword
                                                                              "OUT" appears in the
                                                                              text of the SQL
                                                                              statement. Instead of
                                                                              the access plan tree,
                                                                              the following error
                                                                              message is
                                                                              displayed:

                                                                              Cannot use the
                                                                              OUTPUT option in
                                                                              a DECLARE
                                                                              statement ...

                                                                          o   While trying to
                                                                              "setuser" to a user
                                                                              with NT
                                                                              authentication.
                                                                              Instead of the access
                                                                              plan tree, the
                                                                              following error
                                                                              message is
                                                                              displayed:

                                                                              There is no such
                                                                              user or group
                                                                              ...




                                                3
                                  VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                             Description
                                                       Date
 Indepth for
 SQL Server
               SQ_FPAGS_710_004        Published(b)   25-Apr-              
                                       Released as    2005
               (cont.)                 part of
                                       Bundle Patch
                                                                              While trying to
                                       BU_I3_710_                              calculate the access
                                       002                                     plan hash value. The
                                                                               following error
                                                                               message is
                                                                               displayed:

                                                                               Invalid
                                                                               character value
                                                                               for cast
                                                                               specification

                                                                      The following Performance
                                                                       Warehouse processes ignore
                                                                       invocation parameters (as set
                                                                       in AdminPoint) and use
                                                                       default values instead:

                                                                              Collect Schema
                                                                               Changes.

                                                                              Collect Space
                                                                               Utilization.

                                                                      The Collector agent fails to
                                                                       start when the instance name
                                                                       is longer than 31 characters.

                                                                      The Collector agent
                                                                       (pssq_perf.exe) fails with the
                                                                       following error message:

                                                                       ID : SEVERE-4502990
                                                                       Msg : A PDH function
                                                                       failed. Return code: -
                                                                       2147481643

                                                                      The EMC Storage agent fails
                                                                       to start when only Clariion
                                                                       units exist (no Symmetric
                                                                       units).

                                                                      AdminPoint fails to verify the
                                                                       EMC Storage agent.

                                                                      When upgrading an SQL
                                                                       Server Instance from version
                                                                       6.5, the Performance
                                                                       Warehouse Data Migration
                                                                       utility incorrectly sets the
                                                                       working type to "COM+".



                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                            Description
                                                       Date
 Indepth for
 SQL Server
               SQ_FPAGS_710_004        Published(b)   25-Apr-         In East Asian environments:
                                       Released as    2005
               (cont.)                 part of
                                       Bundle Patch                           Instance Statistics
                                       BU_I3_710_                              are not collected for
                                       002                                     databases with
                                                                               Japanese characters
                                                                               in their name.

                                                                              Failure to associate
                                                                               to Recent Sessions
                                                                               when working in a
                                                                               Chinese
                                                                               environment. The
                                                                               following error is
                                                                               displayed on the
                                                                               Indepth/SQL Server
                                                                               user interface:

                                                                               Cannot
                                                                               communicate with
                                                                               the server

                                                                      The following user interface
                                                                       problems:

                                                                              Sorting by Index
                                                                               Keys after
                                                                               associating to
                                                                               Indexes causes an
                                                                               error. The following
                                                                               error message is
                                                                               displayed in the
                                                                               Association area:

                                                                               The ORDER BY
                                                                               position number
                                                                               61 is out of
                                                                               range ...

                                                                              Statement text is
                                                                               incorrectly formatted
                                                                               when displayed in the
                                                                               Association area grid.




                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                      Release
  Product                Patch ID        Status                              Description
                                                       Date
 Indepth for
 SQL Server
               SQ_FPAGS_710_004        Published(b)   25-Apr-                  The launch from the
                                       Released as    2005
                                       part of
                                                                                SQL workspace to
               (cont.)
                                       Bundle Patch                             the Objects
                                       BU_I3_710_                               workspace with a
                                       002                                      temporary table
                                                                                causes an error. The
                                                                                following error
                                                                                message is
                                                                                displayed:

                                                                                table-database-
                                                                                name column
                                                                                missing from xml
                                                                                request

                                                                               The Recommend tab
                                                                                in the SQL
                                                                                Workspace fails to
                                                                                highlight the correct
                                                                                column when its
                                                                                name is similar to the
                                                                                suffix of another
                                                                                column.

                                                                       The Last Explained (Date-
                                                                        Time) column is not updated
                                                                        when the access plan is not
                                                                        changed.

                                                                       The Statement Cost, as
                                                                        displayed in the Activity
                                                                        workspace, is wrong, if the
                                                                        same statement is executed
                                                                        by different Logins, from
                                                                        different Machines, or by
                                                                        different Programs.

                                                                Requirements

                                                                Before installing this patch, you must
                                                                install the latest cumulative VERITAS
                                                                 3
                                                                i user interface patch. At the release
                                                                date of this patch, that is the
                                                                UI_GUIFP_710_008 patch.

                                                                Obsolete

                                                                This patch is cumulative, and includes
                                                                all updates and fixes from the patches
                                                                SQ_MUAGS_710_001,
                                                                SQ_SQCOL_710_002 and
                                                                SQ_FPAGS_710_003, making those
                                                                patches obsolete.


                                                  3
                                    VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date
 Indepth for
               SP_SPFP_710_001      Rejected       10-Feb-   This patch is relevant for all users
 SAP
                                                   2005
                                                             with an Indepth/SAP installation.

                                                             This patch contains the following
                                                             enhancement:

                                                                    Improved performance of the
                                                                     availability snapshot
                                                                     calculation, reducing the load
                                                                     on the Performance
                                                                     Warehouse database.

                                                             This patch solves the following
                                                             problems:

                                                                    An "Internal data
                                                                     retrieval error"
                                                                     message is displayed when
                                                                     launching the Availability
                                                                     Workspace from the Activity
                                                                     Workspace and then trying to
                                                                     show the Overview view in
                                                                     the Main Area of the
                                                                     Workspace.

                                                                    Installation in the upgrade
                                                                     mode displays only active
                                                                     VERITAS Luminate 3.3
                                                                     instances.

                                                                    When upgrading a VERITAS
                                                                     Luminate 3.3 instance, the
                                                                     upgrade of the planned
                                                                     downtime definitions from
                                                                     VERITAS Luminate 3.3 (in
                                                                     the instance installation) will
                                                                     cause an "25604: Unable
                                                                     to upgrade Luminate
                                                                     settings" error, if the rules
                                                                     end-time is 24:00.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                   Release
  Product             Patch ID        Status                              Description
                                                    Date
 Indepth for
               SP_SPFP_710_002      Obsolete by    28-Feb-   This patch solves the following
 SAP
                                    patch          2005
                                                             problems:
                                    SP_SPFP_7
                                    10_003                          An "Internal data
                                                                     retrieval error"
                                    which was
                                    published as
                                                                     message is displayed when
                                    part of                          launching the Availability
                                    Bundle Patch                     Workspace from the Activity
                                    BU_I3_710_                       Workspace and then trying to
                                    001
                                                                     show the Overview view in
                                                                     the Main Area of the
                                                                     Workspace.

                                                                    Installation in the upgrade
                                                                     mode only displays active
                                                                     VERITAS Luminate 3.3
                                                                     instances.

                                                                    When upgrading a VERITAS
                                                                     Luminate 3.3 instance, the
                                                                     upgrade of the planned
                                                                     downtime definitions from
                                                                     VERITAS Luminate 3.3 (in
                                                                     the instance installation) will
                                                                     cause an "25604: Unable
                                                                     to upgrade Luminate
                                                                     settings" error, if the rules
                                                                     end-time is 24:00.

                                                             Warning

                                                             Do not install patch
                                                             SP_SPFP_710_001. Due to a
                                                             problem, we are replacing it with this
                                                             patch. In case you did install patch
                                                             SP_SPFP_710_001, you must install
                                                             patch SP_SPFP_710_002. This patch
                                                             contains all enhancements and fixes
                                                             as were released in patch
                                                             SP_SPFP_710_001.




                                               3
                                 VERITAS™ i version 7.1 - Patches
VERITAS Software Corporation


                                                     Release
  Product             Patch ID          Status                              Description
                                                      Date
 Indepth for
               SP_SPFP_710_003        Published(b)   20-Jun-   This patch is a cumulative patch that
 SAP
                                      Released as    2005
                                      part of
                                                               fixes the following problems:
                                      Bundle Patch
                                      BU_I3_710_                      Changing the mapping
                                      002                              settings of the Organization
                                                                       or the Locale mapping
                                                                       settings, results in the display
                                                                       of the following error
                                                                       message:

                                                               ORA-00001: unique constraint
                                                               (PW_SPUL_USERLOCALE_DIM.IW_S
                                                               PUL_USERLOC_NAME) violated.

                                                                      The Load metric of "User
                                                                       Connotations" is not showing
                                                                       alert data in the Inform Alerts
                                                                       user interface.

                                                               Obsolete

                                                               This patch is cumulative, and includes
                                                               all enhancements and fixes that were
                                                               previously released in patch
                                                               SP_SPFP_710_002 (and all of it's
                                                               predecessors), therefore making that
                                                               patch obsolete.
 Indepth for
               DN_FPAG_710_001        Published(b)   22-Jul-   This patch contains the full release of
 .NET
                                      Released as    2005
                                      part of
                                                               Indepth/.NET.
                                      Bundle Patch
                                      BU_I3_710_
                                      002

For information on how to view and install patches, refer to Chapter 2 of the VERITAS™ i3™ 7.1
Administration Guide




                                                 3