					For   Battery      Hook-Up

I.    Connect      a six     volt     D.C.   Bell      to   Terminal              I & 2.

2.    Start      the protective         circuit      for        Zone     I at       terminals                    3 8 4.    Connect           all
      Zone      I contacts     into     this    circuit.

3.    ‘Connect     two     No. 6 Dry Ceil           Batteries          (in    series)              to      the        end of     the      protective
       circuit     for     Zone I.

4.    Repeat      steps     2 and 3 for       each      zone      that       is     to      be included                 in the         installation.

5.    Connect  the two           leads inside    the MULTILARM cabinet    to a six volt  battery    (four
      No. 6 Dry Cells           connected     in series).     BE SURE TO OBSERVE POLARITY.     Connect
      the red lead to           plus and black      to negative.

6.     If you plan to use a dialer           or police      alarm wired     into terminals          I and 2, cut
      out the bell       test    on the key lock switch.           You can eliminate        it by removing
      the panel      in the control       box and cutting       the yellow     wire to the bell          relay
      which     is connected      to the key lock switch.           Failure    to perform      this    operation
      will    result    in false    alarms   every time the switch          is moved through          bell    test.
      Leave the other         wires   to the relay     intact.      They allow      the alarm circuit           to
      operate     the dialer’     or police   alarm when an intrusion            takes  place.




                                                                                  No.    Se7      or NP. 97       I       ZONE    ZONE      ZONE   ZONE
                                                                              ----        -------         -__.               1      P          3     4


      FOR        BATTERY              HOOK-UP                                FOR          POWER                       SUPPLY            HOOK-UP




For   Power      Supply     Hook-Up

I.    One energy    pack can be used to operate     alarm zones.      In this  case, each zone
      is wired as a loop circuit      so that short    circuits  will   not show up in the
      circuit  test   or ON position.




                                                                         118
     OPERATING                INSTRUCTIONS

I.   Close        all     doors       and windows.

2.   Turn     key        to     CIRCUIT        TEST.

     A.       If any lamp lights,                it indicates         that  a door or window is open or the
             protection          circuitis         broken       in that    zone.     Recheck all     openings        in that
             zone.       If,the        lamp still         remains     on, turn    control     key to OFF position,
             open cabinet,            and slide        switch      inside   cabinet     for that    zone to the OFF.
             position.           This switch         turns     off that     zone from the alarm system,                but all
             other     zones rema i n p,rotected.                 Then close      cabinet.
                                                        ._-
                                                        -
     B.       If buzzer        sounds,        it indicates        that one or more slide          switches      inside     the
             cabinet       have been turned              off.      (OFF position)         To open cabinet,        first    turn
             the control           key back to the OFF position,                  open cabinet,      and make certain
             that    all     slide       switches      are in the ON posi‘tion.            -Then close     cabinet.         If
             you have deliberately                 turned      off a zone,       ignore    the buzzer.

     C.      If     no        lamp   lights,           and buzzer       does      not   sound,   proceedlto        BELL TEST.

3.   Turn     key to            BELL TEST.              Bell   should     ring.

4.   Turn     key to            ON and         leave     premises.

NOTE:     Cover          is protected  with tamper                      switch      connected     to   Zone   I;    Do not   turn
          alarm          ON with cover open.




                                                                        119
                                                                                                                              (,..
I: TROUBLESHOOTING Nos. 1002 AND 1004                                                                                       A,
                                                                                                                                :
   TROUBLE:   I.   BELt OPERATES ON BELL TEST, tlGHT INDICATES                   INTERRUPTED ZONE, BELL DOES
                   NOT OPERATE ON DURING AN ALARM CONDITION.

                              PROBABLE CAUSE                                                   REMEDY

              A. The bell    battery       is   reversed     in    its     A. Reverse      wires   to    bell   battery.
                 connection.


   TROUBLE:   2.   PROTECTIVE CIRCUIT IS INTACT,                 ZONE LAMP WILL NOT GO OUT; AND ALARM SOUNDS
                   WHENEVER SYSTEM IS ARMED.

                              PROBABLE CAUSE                                                   REMEDY

              A. Charred      or corroded      contacts     on pro-        A. Replace   plug-in         relay   for   the
                 tective      circuit   relay.                                troub I ed zone.


   TROUBLE:   3.   ZONE LAMP DOES NOT GO ON WHEN A PARTICULAR ZONE ENTRY POINT                             IS OPENED.

                              PROBABLE CAUSE                                                   REMEDY

              A. Burned      out   lame.                                   A. Replace      lamp with      #47 standard
                                                                              lamp.


   TROUBLE:   4.   A ZONE GIVES FALSE ALARMS.

                              PROBABLE CAUSE                                                   REMEDY

              A. A swinger      exists      in the protective              A. Use No. I2 tester     or equivalent
                 circuit    (verlfv    r
                                           bv switchina
                                           ,
                                                              trouble-        to troubleshoot   circuit     (see
                 some circuit        with another         zone on the         Part   I, Section H for instructions
                 pane I . If new zone gives             false    alarms        in the use of the No. I2 tester.
                 a swinger      .is indicated        in the pro-
                 tective    circuit.         If the same zone
                 continues      to alarm,       the trouble        is
                  in the control         instrument.


   TROUBLE:   5.   BELL(S)    DO NOT OPERATE PROPERLY.

                   See General Troubleshooting             for     1000 Series   Control      Instruments,
                   TROUBLES 3 and 8.




                                                             120
                                    Description                            &                    Description       .

                       CONTROL INSTRUMENT                                  I034      ZONE EXPANSION CENTER

     a     IO06
                   .   Installation...........l2l-I25
                       Troubleshooting....,...l26-132
                       DAY/NIGHT DELUXE CONTROL
                       lnstallation...........l33-135
                                                                           1035
                                                                                     Installation...........222-22
                                                                                     Troub I eshoot i ng. ..... . .. .230-233.
                                                                                     DAY ZONE ADAPTER
                                                                                     lnstallation...........234-23
                                                                                                                               9


                                                                                                                               7
                       Troubleshooting........l59-167                                Troubleshooting........238-23             9
           I007        DELUXE CONTROL WITH E/E DELAY
                       Installation...........l36-137                      III4       COMBINATION BELL AND CONTROL
                       Troubleshooting........l38-142                                 lnstal      lation...........l48-15     0
         . 1008        DAY .& NIGHT CONTROL                                           Troubleshooting........l51-15           4
                       lnstallation...........l43-144                      523 I      REMOTE CONTROL STATION
                       Troubleshooting....l11-116,145                                 Installation................4           3
.’
          .A009        DAY 8 NIGHT CONTROL                                 5240       DIGITAL         REMOTE STATION
                       lnstallation...........l43-144                                 lnstallation...........240-24           4
                       1roublashooting....l11-1(6,145                      524 I      DIGITAL         REMOTE STATION
           1014        BELL BOX WITH BUILT-IN          CONTROL                         lnstallation...........245-24          8
                       Installation...........l46-147                      5246       REMOTE CONTROL STATION
                       Troubleshooting........151-153                                  Installation................4           3
           IQ20        DAY/NIGHT DELUXE CONTROL
                        Installation..........:l55-158                                 U. L.   L I STED CONTROLS
                       Troubleshooting........l59-167
                                                                           Mode I A(AR,ARL)     GRADE A SYSTEM
                       ALARM PROCESSING CENTERS                                       Wiring    Diagram.............28    3
                                                                                     Troubleshooting........285-29        0
           I022         ALARM PROCESS ING CENTER                           Mode I AD(ADL) GRADE A SYSTEM
                        Installation...........249-260                                Wiring    Diagram.............28    4
                        Troubleshooting........274-282                                Troubleshooti.ng........285-29      I
           1022-12      ALARM PROCESSING CENTER                            Mode I AM(AML) GRADE A SYSTEM
                        Installation....‘.......261-273                               Wiring    Diagram.............29    2
                        Troubleshooting........274-282                                Troubleshooting........296-30       2
           IO23         ALARM PROCESSING CENTER                            Mode I AM(L)-24      24 HR. GRADE A SYSTEM
                        Installation...........l68-I73                                Wiring    Diagram.............29    4
                        Troubleshooting........l74-182                                Special    Note...............29    5
           IO24         ALARM PROCESS I NG CENTER                                     Troubleshooting........296-30       4
                        Installation...........l83-I88                     Mode I AP(L)-24      24 HR. GRADE A SYSTEM
                        Troubleshooting........l89-I97                                Wiring    Diagram.............30    5
           1026.     -- ALARM PROCESSING CENTER                                       Troubleshooting........306-31        I
                        Installation...........l98-20                  3   Mode I V-AML HIGH SECURITY ALARM SYSTEM
                        Troubleshooting........213-22                  I              Wiring    Diagram.............29    3
                        ALARM PROCESSING CENTER                                       Troubleshooting........296-30       2
                        Installation             ......... ..204-20    8   Mode I ZML 4 ZONE GRADE A ALARM SYSTEM
                        Troubleshooting........213-22                  I              Wiring    Diagram.............31    2
                        ALARM PROCESSING CENTER                                       Operating       Instructions.....31 3
                        Installation             ......... ..209-212                  Troubleshooting....l20,313-314
                        Troubleshooting........213-22                  I

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:4
posted:6/15/2011
language:English
pages:4