Cover Contents indd (PDF) by xumiaomaio

VIEWS: 272 PAGES: 137

									                                      eCATALOGUE
                                                 Australia


               WORLD LEADER OF INNOVATIVE SOLUTIONS IN FIRE DETE C T I O N A N D A L A R M S YS T E M S




AUS / PAGE 1     CONTACT AMPAC                 HOME        CONTENTS      SEARCH      ZOOM     PRINT       EXIT
   AMPAC TECHNOLOGIES


      Ampac Technologies is the largest independent and privately owned                          CONTROL PANELS                                                      3
      manufacturer and supplier of fire detection and alarm systems in Australia.
                                                                                                 ZoneSense DH4 Conventional                                          3
                                                                                                 ZoneSense PLUS Conventional                                         6
      Ampac specialises in the research & development, design, manufacturing,                    FireFinder Conventional/Intelligent                                17
      marketing and distribution for a complete range of system solutions. We
      supply systems for a vast variety of applications including commercial and                 EMERGENCY WARNING SYSTEMS                                          36
      industrial buildings, mines, prisons, hospitals, hotels and multi-residential              EV3000 Emergency Warning System                                    38
      complexes.                                                                                 Speakers                                                           44
                                                                                                 DETECTORS                                                          49
      Ampac operates Australia-wide through a network of branch offices. These
      offices provide sales and technical support for fire installation & EWIS                      Orbis Conventional                                                 49
      contractors as well as fire discipline and electrical consulting engineers.                 XP95 Intelligent                                                   54
      We also work with building owners and maintenance engineers to make                        Discovery Intelligent                                              59
                                                                                                 Orbis Marine Conventional                                          67
      recommendations for future planning or budgeting.
                                                                                                 Orbis IS Conventional                                              70
                                                                                                 XP95 IS Intelligent                                                75
      Since its inception in 1974, Ampac has grown to become a thriving global                   Flame Detectors Intelligent                                        80
      operation with a focus on quality and exceptional customer service and
      support. Our passion for growing our business through the relationships                    FASTSENSE                                                          86
      we have with our customers is one that energises us. It fuels our desire                   FastSense 25/100/PLUS High Sensitivity Detection                   88
      to make better products, implement more efficient systems, grow our                          FastSense SenseNET                                                 91
      network of operations and develop our people.                                              FastSense Fittings                                                 92
                                                                                                 INTERFACES                                                         94
      Ampac Technologies is ISO 9001 accredited locally and also holds overseas
      approvals with LPCB & UL for other key global markets.                                     Ampac I/O Devices                                                  95
                                                                                                 Apollo I/O Devices                                                 99
      Ampac’s comprehensive range of products enables us to deliver complete                     AUDIO VISUAL SIGNALLING                                           101
      solutions for fire detection and alarm systems of any size for any customer.                XP95/Discovery Sounders, Beacons & Sounder Beacons inc Bases      102
      Indeed, developing unparalleled customer partnerships drives our desire                    Ampac Bells, Strobes & Remote Indicators                          107
      to be ‘World leaders of Innovatiove Solutions in Fire Detection and Alarm                  Klaxon Sounder Beacon                                             115
      Systems’.                                                                                  Electronic Sounders                                               116
                                                                                                 ANCILLARIES                                                       118
                                                                                                 Power Supplies                                                    118
                                                                                                 Manual Call Points                                                120
                                                                                                 Occupant Warning Systems Amplified Sound Systems                   125
                                                                                                 Electro-Magnetic Door Holders                                     127
                                                                                                 Document Cabinets                                                 131
                                                                                                 Test Equipment                                                    132
                                                                                                 Batteries                                                         135



AUS / PAGE 2                   CONTACT AMPAC                                   HOME   CONTENTS            SEARCH               ZOOM          PRINT          EXIT
    CONTROL PANELS




ZoneSense DH4
Conventional Control Panel
The ZoneSense DH4 Control Panel is a simple and low cost 4 zone panel. It is a local
alarm panel which means that it is not suitable to be directly connected to fire brigade
monitoring equipment. It is an ideal fire panel for any small residential applications
(not requiring brigade monitoring) or can also be used as a door holder control panel.
Each of the 4 zones can be connected up to 40 x high quality commercial grade
conventional fire detectors to deliver a high quality detection & alarm system. It is
possible to use the ZoneSense panel in ‘Mains only’ option mode which eliminates the
need to connect back up batteries. Both ABS and Metal versions are available.




❚   Dual Door Holder Outputs
❚   Mains Only Mode
❚   Low Quiescent Current
❚   Single PCB architecture
❚   Walk Test Facility
❚   Class Change Input
❚   Alert Input
❚   Up to 40 Conventional detectors per Zone
❚   Available in ABS (BX1) and Metal (BX10) cabinet versions




AUS / PAGE 3                   CONTACT AMPAC                                  HOME        CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   CONTROL PANELS ZONESENSE DH4 Conventional



                                                                                Power Supply
                                                                                Mains Supply voltage                204 – 264 VAC @ 47 – 63Hz
                                                                                Nom. Operating voltage              27 VDC
                                                                                Power Supply Current                1.6 A (max)
                                                                                Quiescent Current                   20 mA (without Door Holder)
                                                                                Operating Temperature               -5° to +55° C
                                                                                Relative Humidity                   25% - 75%

                                                                                Zone Detection Circuit
                                                                                No of Zones                         Four (4) x 2-wire system
                                                                                Zone Monitoring                     Open and Short circuit
                                                                                Zone Quiescent Current              4mA, 10uF EOL
                                                                                No of Detectors/Circuits            40 (max)
                                                                                End Of Line (EOL)                   10uF EOL
                                                                                Max Cable Length                    3km (Based on cable resistive and capacitive values of 50Ω
     ZoneSense DH4 – Metal Cabinet            ZoneSense DH4 – ABS Cabinet                                           and 1uF respectively)

                                                                                Outputs Available
                                                                                Alarm Outputs (monitored)           Open Collector, 250mA
                                                                                                                    (2 O/P’s available) 10KΩ EOL
                                                                                Door Holder outputs (monitored)     Open Collector, 250mA
                                                                                                                    (2 O/P’s available) 10KΩ EOL
                                                                                Fire Output Relay (voltage free)    NO, C, NC
                                                                                                                    Contact rating: 1A @ 30VDC
                                                                                Fault Output Relay (voltage free)   NO, C, NC
                                                                                                                    Contact rating: 1A @ 30VDC
                                                                                Auxiliary DC Output                 150mA @ 24VDC

                                                                                Miscellaneous Features
                                                                                Class Change Input                  Non-Latching, switched -ve
                                                                                Alert Input                         Non-Latching, switched -ve
                                                                                Battery Monitoring                  4 Way DIP switch array (factory set to “OFF”)




AUS / PAGE 4                  CONTACT AMPAC                          HOME   CONTENTS               SEARCH           ZOOM             PRINT             EXIT
   CONTROL PANELS ZONESENSE DH4 Conventional



                                                                                Mechanical
                                                                                Material
                                                                                ABS Cabinet                            ABS/Blend High Impact
                                                                                Metal Cabinet                          1.2mm Mild Steel
                                                                                Finish
                                                                                ABS Cabinet                            ABS Light Grey
                                                                                Metal Cabinet                          Metal Oyster Matt Ripple
                                                                                ABS (BX1) Cabinet                      H 300mm x W 360mm x D 100mm
                                                                                Metal Cabinet (BX10)                   H 300mm x W 360mm x D 100mm
                                                                                Packed                                 H 310mm x W 500mm x D 110mm
                                                                                Weight Packed excluding batteries
                                                                                ABS                                    3kg
                                                                                Metal                                  5.2kg


     ZoneSense DH4 – Metal Cabinet            ZoneSense DH4 – ABS Cabinet         ZoneSense DH4 ABS (BX1) excl Batteries                                                2250-4200
                                                                                  ZoneSense DH4 METAL (BX10) excl Batteries                                             2250-4250
                                                                                  Metal BX10 Surround                                                                  ENC3016-A

                                                                                Note:
                                                                                Gyprock fixing (toggle brackets) are available to flush fit any Ampac ABS enclosure into a wall cavity
                                                                                Item No (4210-0002 & 4210-0003 )




AUS / PAGE 5                  CONTACT AMPAC                          HOME   CONTENTS              SEARCH              ZOOM              PRINT            EXIT
    CONTROL PANELS




ZoneSense PLUS
Conventional Control Panel
The Ampac ZoneSense PLUS Fire Alarm Control Panel is a versatile four or eight zone
conventional panel. The user friendly navigation system provides simple operation
during an emergency while also enabling complex cause and effect programming to be
undertaken.

A range of modular panel add-on kits allows the panel to be professionally tailored to
the requirements of each installation. This means small conventional panels can now be
used in a wider range of applications.

ZoneSense PLUS offers you complete control. The panel can be easily upgraded and
programmed on site. ZoneSense PLUS is approved to AS4428 and is available in ABS
(BX1) or metal cabinets (BX20) with either four (4) or eight (8) zone conventional
detection circuits.



❚   Available in 4 Zone or 8 Zone Panels
❚   Up to 40 Conventional detectors per zone
❚   RS485 port supports a range of Add-on modules
❚   Available in ABS (BX1) and Metal (BX20) cabinet versions
❚   Complies with AS4428




AUS / PAGE 6                   CONTACT AMPAC                               HOME          CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   CONTROL PANELS ZONESENSE PLUS Conventional



                                                                                   ZoneSense PLUS – ABS and Metal

                                                                                   Power Supply
                                                                                   Mains Supply voltage                     204 – 264 VAC @ 47 – 63Hz
                                                                                   Nom. Operating voltage                   27 VDC
                                                                                   Power Supply Current                     2 A (max)
                                                                                   Quiescent Current                        40.5 mA (min)

                                                                                   Zone Detection Circuit
                                                                                   No of Zones                              Four (4) or Eight (8) x 2-wire system
                                                                                   Zone Monitoring                          Open and Short circuit
                                                                                   Zone Quiescent Current                   4mA, 10uF EOL
                                                                                   No of Detectors/Circuits                 40 (max)
                                                                                   Eon Of Line Value (EOL)                  3K3Ω (default), 4K7Ω, 6K8Ω, 10KΩ and 10uF (Optional)
                                                                                   Max Cable Length                         3km (Based on cable resistive and capacitive values of 50Ω
     ZoneSense PLUS – ABS Cabinet             ZoneSense PLUS – Metal Cabinet                                                and 1uF respectively)

                                                                                   Outputs
                                                                                   Comms Output                             RS485 (4 and 8 zone only)
                                                                                   EXT Bell Output (monitored)              1A (max) 10KΩ EOL
                                                                                   Warning Sys Output (monitored)           1A (max) 10KΩ EOL
                                                                                   ACF Output (monitored)                   1A (max) 10KΩ EOL
                                                                                   ASE Output (monitored)                   1A (max) 10KΩ EOL
                                                                                   Reset/Buzzer                             Output Open Collector, 40mA 15sec pulse
                                                                                   Fire Alarm Output Relay (voltage free)   NO, C, NC. Contact rating: 1A @ 30VDC
                                                                                   Fault Output Relay (voltage free)        NO, C, NC. Contact rating: 1A @ 30VDC
                                                                                   Auxiliary DC Output (monitored)          500mA @ 24VDC10KΩ EOL

                                                                                   Miscellaneous
                                                                                   MCP input                                Non-Latching, switched –ve
                                                                                   Fault input                              Non-Latching, switched –ve
                                                                                   Door Switch                              Non-Latching, switched –ve

                                                                                   Environmental
                                                                                   Operating Temperature                    -5° to +55° C
                                                                                   Relative Humidity                        25% - 75%




AUS / PAGE 7                  CONTACT AMPAC                            HOME    CONTENTS              SEARCH                 ZOOM            PRINT            EXIT
   CONTROL PANELS ZONESENSE PLUS Conventional



                                                                                  ZoneSense PLUS – ABS
                                                                                  Certain ABS versions also come optionally with the provision of extra window space. These windows
                                                                                  are to allow for space to add ZoneSense Plus Add on Modules into the panel fascia.

                                                                                  Mechanical
                                                                                  Material                               ABS/Blend High Impact
                                                                                  Finish                                 ABS Light Grey
                                                                                  Dimensions                             300mm (H) x 360mm (W) x 100mm (D)
                                                                                  Weight packed excluding Batteries      3kg


                                                                                    ZoneSense PLUS Control Panel
                                                                                    4 Zone ABS (BX1)                                                                      2550-1100
                                                                                    8 Zone ABS (BX1)                                                                      2550-1200
                                                                                    4 Zone ABS (BX1) with windows                                                         2550-2100
     ZoneSense PLUS – ABS Cabinet              ZoneSense PLUS – ABS Cabinet         8 Zone ABS (BX1) with windows                                                         2550-2200
                                                      with Windows                  4 Zone EV20 OWS Fitted                                                                2550-0120
                                                                                    8 Zone EV20 OWS Fitted                                                                2550-0220
                                                                                    4 Zone EV40 OWS Fitted                                                                2550-0140
                                                                                    8 Zone EV40 OWS Fitted                                                                2550-0240
                                                                                    ABS Joiner Moulding                                                                  ENC1851-A
                                                                                    Ancillary Cabinet ABS (BX1)                                                           2510-9001

                                                                                  Note:
                                                                                  Gyprock fixing (toggle brackets) are available to flush fit any Ampac ABS enclosure into a wall cavity
                                                                                  Item No (4210-0002 & 4210-0003 )




 ZoneSense PLUS – ABS Ancillary Cabinet




AUS / PAGE 8                   CONTACT AMPAC                           HOME   CONTENTS              SEARCH              ZOOM              PRINT            EXIT
   CONTROL PANELS ZONESENSE PLUS Conventional



                                                                                    ZoneSense PLUS – Metal
                                                                                    A diverse range of factory pre assembled ZoneSense Plus products are made available for the
                                                                                    installers convenience. These include a range with occupant warning system pre fitted and or Agent
                                                                                    Release (Gas) module fitted.
                                                                                    It is also possible to fit ZoneSense Plus “add on modules” after purchasing a standard ZoneSense Plus
                                                                                    panel as long as there is space provision on the enclosure to fit the module.

                                                                                    Mechanical
                                                                                    Material                               1.2mm Mild Steel
                                                                                    Finish                                 Metal Oyster Matt Ripple
                                                                                    Dimensions                             ZoneSense Plus Metal: 500(H) x 405(W) x 145(D) mm
                                                                                                                           Metal Ancillary Cabinet: 250(H) x 405(W) x 145(D) mm
                                                                                    Weight packed excluding Batteries      ZoneSense Plus Metal: 8.5kg
                                                                                                                           Metal Ancillary Cabinet: 2kg
     ZoneSense PLUS – Metal Cabinet            ZoneSense PLUS – Metal Cabinet
                                                 with Agent Release Module            ZoneSense PLUS Control Panel
                                                                                      4 Zone Metal (BX20) with MCP                                                           2550-0100
                                                                                      8 Zone Metal (BX20) with MCP                                                           2550-0200
                                                                                      4 Zone Metal (BX20) with MCP and ASE                                                   2550-0300
                                                                                      8 Zone Metal (BX20) with MCP and ASE                                                   2550-0400
                                                                                      4 Zone EV20 OWS Fitted                                                                 2550-0120
                                                                                      8 Zone EV20 OWS Fitted                                                                 2550-0220
                                                                                      4 Zone EV40 OWS Fitted                                                                 2550-0140
                                                                                      8 Zone EV40 OWS Fitted                                                                 2550-0240
                                                                                      Ancillary Cabinet Metal (BX20)                                                         8510-9001
                                                                                      Surround for Metal Cabinet only                                                       ENC1798-A
                                                                                      Surround for Metal & Ancillary Cabinet                                                ENC1797-A


                                                                                    ZoneSense PLUS – Rack Mount
                                                                                    For added flexibility ZoneSense Plus Rack versions are now available. This allows a ZoneSense Plus
                                                                                    Fire indicator panel to be easily integrated in a rack arrangement with other larger models of Ampac
                                                                                    warning systems

                                                                                      ZoneSense PLUS Control Panel
                                                                                      4 Zone Combo Rack Mount                                                               2553-0400
                                                                                      8 Zone Combo Rack Mount                                                               2553-0800




AUS / PAGE 9                   CONTACT AMPAC                            HOME    CONTENTS              SEARCH              ZOOM              PRINT            EXIT
   CONTROL PANELS ZONESENSE PLUS Conventional – Add Ons



                         Input Board

                         ❚   Provides inputs for sprinkler pumps, tanks, valves, shutdowns, etc
                         ❚   16 inputs per board                                                  Voltage                          24 VDC
                                                                                                  Quiescent current                2.6 mA
                         ❚   Inputs map to relays or indicators
                                                                                                  Max current                      45 mA
                         ❚   Programmed via the ZoneSense PLUS front panel                        Output rating                    0.5 amp at 24 VDC
                         ❚   Max 1 per ZoneSense PLUS                                             Operating temperature            -5°C to +55°C (no icing)
                                                                                                  Relative humidity                0 to 95% (non condensing)
                                                                                                  Weight                           120 grams

                                                                                                   Input Board                                       4310-0040




                         Relay Board

                         ❚   Provides volt free change over contacts
                         ❚   8 relay outputs per board                                            Voltage                          24 VDC
                                                                                                  Quiescent current                2.4 mA
                         ❚   Programmed via the ZoneSense PLUS front panel
                                                                                                  Max current                      80 mA
                         ❚   Max 1 per ZoneSense PLUS system                                      Relay contact rating             3 amp at 24 VDC
                         ❚   Remote version available – DIN Mount chassis                         Operating temperature            -5°C to +55°C (no icing)
                         ❚   Remote version communication via RS485 serial link                   Relative humidity                0 to 95% (non condensing)
                                                                                                  Weight                           130 grams

                                                                                                   Relay Board                                       4310-0050
                                                                                                   Relay Board (Remote)                              4310-0055




AUS / PAGE 10      CONTACT AMPAC                               HOME               CONTENTS        SEARCH            ZOOM   PRINT      EXIT
   CONTROL PANELS ZONESENSE PLUS Conventional – Add Ons



                         Sounder Board

                         ❚   Provides 8 monitored switched 24 VDC outputs per board
                         ❚   Programmed via the ZoneSense PLUS front panel                      Voltage                              24 VDC
                                                                                                Quiescent current                    5.6 mA
                         ❚   Max 1 per ZoneSense PLUS
                                                                                                Max current                          26 mA
                                                                                                Output rating (ea)                   500 mA at 24 VDC
                                                                                                Operating temperature                -5°C to +55°C (no icing)
                                                                                                Relative humidity                    0 to 95% (non condensing)
                                                                                                Weight                               100 grams

                                                                                                 Sounder Board                                         4310-0060




                         Fire Brigade Board

                         ❚   Provides common outputs for connection to fire brigade signalling
                             equipment                                                          Voltage                              24 VDC
                                                                                                Quiescent current                    9 mA
                         ❚   5 outputs – Alarm, Fault, Isolate, Battery Fail and 2nd Alarm
                                                                                                Max current                          52 mA
                         ❚   Programmed via the ZoneSense PLUS front panel                      Output rating                        3 amp at 24 VDC
                         ❚   Max 1 per ZoneSense PLUS                                           Operating temperature                -5°C to +55°C (no icing)
                                                                                                Relative humidity                    0 to 95% (non condensing)
                                                                                                Weight                               110 grams

                                                                                                 Fire Brigade Board                                    4310-0070




AUS / PAGE 11      CONTACT AMPAC                             HOME              CONTENTS         SEARCH                ZOOM   PRINT      EXIT
   CONTROL PANELS ZONESENSE PLUS Conventional – Add Ons



                         Fire Fan Module

                         ❚   Controls and monitors fire fans, dampers, sprinkler pumps etc.
                         ❚   4 controls per module                                                     Voltage                           24 VDC
                                                                                                       Quiescent current                 13.5 mA
                         ❚   Separate start and stop output per control
                                                                                                       Max current                       50 mA
                         ❚   3 status inputs per control                                               Relay contact rating              3 amp at 24 VDC
                         ❚   Labels can be modified on site                                             Operating temperature             -5°C to 55°C
                         ❚   Programmed via the FACP front panel                                       Humidity                          0 to 95% relative humidity
                         ❚   Max 1 per FACP                                                            Weight                            230 grams
                         ❚   Location or title descriptor label


                                                                                                        Fire Fan Module                                     4310-0021




                         Switch/Indicator Card

                         ❚   Controls and monitors solenoid test switches, manual shutdowns etc
                         ❚   Eight (8) push on / push off switches per card                             Voltage                           24 VDC
                                                                                                       Quiescent current                 3.6 mA
                         ❚   Switches map to relays – requires relay board (Order Code: 4310-0050)
                                                                                                       Max current                       8 mA
                         ❚   One (1) status indicator per switch – requires input board (Order Code:   Operating temperature             -5°C to 55°C
                             4310-0040)                                                                Humidity                          0 to 95% relative humidity
                         ❚   Labels can be modified on site                                             Weight                            100 grams
                         ❚   Programmed via the FACP front panel
                         ❚   Max 1 per FACP
                         ❚   Location or title descriptor label

                                                                                                        Switch/Indicator Card                               4310-0030




AUS / PAGE 12      CONTACT AMPAC                               HOME               CONTENTS             SEARCH             ZOOM   PRINT      EXIT
   CONTROL PANELS ZONESENSE PLUS Conventional – Add Ons



                         Agent Release Module

                         ❚   Compliance with AS4214
                         ❚   Controls & Monitors Agent release system                         Voltage                                        24 VDC
                                                                                              Quiescent current                              28.5 mA
                         ❚   Outputs for warning signs & activation devices
                                                                                              Max current                                    1.5 A
                         ❚   Inputs for signals from pressure switches & valves               Relay contact rating                           3 amp at 24 VDC
                         ❚   Serial connection to Agent release (LCS) Local control Station   Operating temperature                          -5°C to 55°C
                         ❚   Programmed via the FACP front panel                              Humidity                                       0 to 95% relative humidity
                         ❚   Maximum is 1 per FACP                                            Weight                                         250 grams
                         ❚   Location or title descriptor label
                                                                                               Agent Release Module                                              4310-0011




                         Agent Release – Local Control Station

                         ❚   Remote Agent release LCS
                         ❚   Complies with AS4214                                             Material                    1.2mm steel for Back Box
                                                                                              Finish                      Oyster matt ripple
                         ❚   For Use only with Agent release Module 4310-0011
                                                                                              Dimension                   233H x 186W x 47D mm
                         ❚   Double Action manual Agent release facility                      Weight                      860 grams
                         ❚   Toggle between initial & reserve agent                           Operating Voltage           27VDC
                         ❚   Can install up to 8 x LCSs per panel                             Quiescent Current           40.5mA
                                                                                              Monitored Inputs            Pressure Switch; Low Pressure Switch; Interlock
                                                                                              Manual Release              2A @ 27VDC (Current Limited)
                                                                                              Stage 1 & 2                 Switched 1A @ 27VDC
                                                                                              System Inoperative          1A @ 27VDC
                                                                                              Gas Fired                   1A @ 27VDC
                                                                                              Comms Output                RS485

                                                                                               Local Control Station                                             4310-0019




AUS / PAGE 13      CONTACT AMPAC                               HOME               CONTENTS    SEARCH               ZOOM        PRINT             EXIT
   CONTROL PANELS




ZoneSense PLUS AR
Agent Release Panel
The ZoneSense PLUS AR (Agent Release) Panel is a dedicated panel for agent release
systems. Housed in a metal cabinet, the ZoneSense PLUS AR is available in either four
(4) or eight (8) zones. Based on a ZoneSense PLUS Fire Alarm Control Panel (FACP), the
AR version is fitted with an Agent Release Panel Add-on (control card and termination
board) and a dual action yellow manual call point as standard. The Agent Release panel
add-on option is factory set.



❚ Dedicated Agent Release system - purpose built with a host of ancillary products to
  suit
❚ Comprehensive system status – the AR panel includes a number of system status
  indicators that facilitates ease of operation and maintenance
❚ Local Control Station with control and indication – mimics full status of the Agent
  Release panel. An outdoor version of this product is available
❚ User interface and operation based around Industry Fire Emergency procedures
  – ensures that the system installed is intuitive and easy to use
❚ Dual action Manual Call Point – the yellow MCP is a break glass type and requires
  a dual action to be activated i.e. lift the protective transparent cover and break the
  glass
❚ Agent Release Panel is compliant with AS4214




AUS / PAGE 14                   CONTACT AMPAC                                  HOME        CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   CONTROL PANELS ZoneSense PLUS AR



                                                         Fire Alarm Control Panel
                                                         Operating Voltage              23 to 28 VDC
                                                         Quiescent Current              37 mA (minimum)
                                                         Power Supply                   27VDC (nominal) @ 2Amps
                                                         Ext Bell Output                1A (max) – monitored
                                                         Warning Sys Output             1A (max) – monitored
                                                         ACF Output                     1A (max) – monitored
                                                         ASE Output                     1A (max) – monitored
                                                         Fire Alarm Output              Volt free 1A @ 24 VDC
                                                                                        Open Collector Output
                                                         Fault Output                   Volt free 1A @ 24 VDC
                                                                                        Open Collector Output
                                                         Aux DC Output                  500mA @ 24 VDC – monitored
                                                         Reset/Buzzer                   Open Collector Output
                                                         Communications Output          RS485
          ZoneSense PLUS AR                              End-Of-Line Values             3k3 (fitted as standard), 4k7, 6k8, or 10k ohms, 10μ Farad
                                                         Material                       1.2 mm mild steel
                                                         Finish                         Oyster matt ripple
                                                         Dimension                      Metal Cabinet: 500H x 405W x 145D mm
                                                                                        Metal ancillary cabinet: 250H x 405W x 145D mm
                                                         Weight (excluding batteries)   8kg

                                                         Agent Release System
                                                         Pressure Switch Input          Monitored Input
                                                         Low Pressure Switch Input      Monitored Input
                                                         Interlock Input                Monitored Input
                                                         Gas Fired Output               Volt Free Changeover
                                                                                        1A@24VDC
                                                         System Inoperative Output      Volt Free Changeover
                                                                                        1A@24VDC
                                                         Stage 1 Output                 Monitored
                                                         Stage 2 Output                 Monitored
                                                         Release Initial Agent Output   Monitored current limited 2A max
                                                         Release Reserve Agent Output   Monitored current limited 2A max




AUS / PAGE 15                 CONTACT AMPAC   HOME   CONTENTS              SEARCH       ZOOM            PRINT              EXIT
   CONTROL PANELS ZoneSense PLUS AR – Ancillary Products



                              Agent Release Warning Signs

                              The AR panel supports a 2-wire connection to warning signs. The 2-wire
                              connection supports both single or dual stage signs. The latter is possible      ACP-04 Manual Call Point Yellow                           213-0061
                              because of the voltage reverse technology adopted by the AR panel.               ACP-04 Manual Call Point Hinged Cover                     213-0057
                              Multiple warning signs may be connected to the AR panel. The connection          Warning sign back box (IP50) no fascia                    207-0020
                              will be in a ‘daisy chain’ configuration with the last warning sign fitted with    Special wording fascia only                               207-0021
                              an End-Of-Line (EOL) resistor. The EOL resistor facilitates the monitoring of    “Fire Alarm, Do Not Enter” fascia only                    207-0022
                                                                                                               “Fire Alarm, Evacuate Area” fascia only                   207-0023
                              the warning sign circuit. A maximum of 6 warning signs may be fitted
                                                                                                               “Fire Door Closing” fascia Only                           207-0024
           IP50 Model         to an AR panel.
                                                                                                               “Do Not Enter, Gas Discharged” fascia only                207-0025
                                                                                                               “Extinguishing System Inoperative” complete IP50          207-0040
                              An on-board buzzer fitted to every sign provides audible warning.                 Warning sign back box (IP65) no fascia                    207-0030
                              However in the event AS1670.4 audible warning tones are required,                Special wording fascia only                               207-0031
                              external electronic sounders may be connected directly to each warning           “Fire Alarm, Do Not Enter” fascia only                    207-0032
                              sign. An external switch may be connected to the sign to mute audible            “Fire Alarm, Evacuate Area” fascia only                   207-0033
                              warning.                                                                         “Do Not Enter, Gas Discharged” fascia only                207-0034
                                                                                                               “Extinguishing System Inoperative” complete IP65          207-0041




           IP65 Model




AUS / PAGE 16           CONTACT AMPAC                                HOME              CONTENTS               SEARCH            ZOOM             PRINT            EXIT
    CONTROL PANELS




FireFinder
Conventional / Intelligent
Fire Alarm Control Panel
FireFinder is a state of the art multi microprocessor controlled Intelligent Fire Alarm
Control Panel. Modular in design, the FireFinder provides flexibility and versatility
that can be configured to operate with both intelligent analogue addressable and
conventional devices in the one system.

Available in single loop or multiple loop configurations, the FireFinder supports the
leading Apollo XP95 and Discovery detector protocols. The Ampac ConfigManager
software tools provide a powerful combination with the FireFinder to configure
the system operational and functional characteristics of an installation. Enhanced
networking capabilities offer the user extended applications with FireFinder
incorporating a Master/ Slave Fire control panel arrangement, true Peer to Peer systems,
data gathering panels and SmartGraphics a PC based application for the supervision,
monitoring and control of larger fire management systems.

❚   Clear back-lit 40 character 8 line LCD display
❚   Programming options via the front panel or laptop computer
❚   Remote system interrogation and diagnostics
❚   Extensive Alarm Management resources
❚   Self Auto Learn capabilities
❚   Day Night sensitivity settings
❚   Versatile multi processor architecture
❚   Event log and printer options
❚   SPOT – Single Person Operation Test
❚   Flexible modular expansion and panel Add Ons
❚   Optional 32, 64, 96 & 128 zone indicators
❚   SmartTerminal repeater options




AUS / PAGE 17                   CONTACT AMPAC                                    HOME      CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent AS4428



                                                                                                 Electrical
                                                                                                 Power Supply                  85 to 264 VAC
                                                                                                 Output Voltage                27 VDC
                                                                                                 Quiescent Current             450mA (min)
                                                                                                 Battery Capacity              12 Ah (min)

                                                                                                 Outputs
                                                                                                 Bell 1 (monitored)            Switched                   24 VDC 2A
                                                                                                 Bell 2 (monitored)            Switched                   24 VDC 2A
                                                                                                 Auxiliary (monitored)         Switched                   24 VDC 2A
                                                                                                 Auxiliary (unmonitored)       Volt free                  1A @ 24 VDC
                                                                                                 EWS (monitored)               Switched                   24 VDC 2A
                                                                                                 EWS (unmonitored)             Volt free                  1A @ 24 VDC
                                                                                                 Fault                         Volt free                  1A @ 24 VDC
                                                                                                 Isolate                       Volt free                  1A @ 24 VDC
            FireFinder SP1X                                 FireFinder SP8X                      Alarm                         Volt free                  1A @ 24 VDC
  Conventional / Intelligent Control Panel        Conventional / Intelligent Control Panel
                                                                                                 Valve Monitor                 Volt free                  1A @ 24 VDC
                                                                                                 Battery Fail                  Volt free                  1A @ 24 VDC

                                                                                                 Mechanical
                                                                                                 Materials / Finish            1.2mm steel / Arch White powder coat
                                                                                                 Construction                  Modular
                                                                                                 Dimensions                    SP1X                         500H x 405W x 145D mm
                                                                                                                               SP8X                         840H x 515W x 170D mm
                                                                                                                               SP16X                        1200H x 625W x 240D mm
                                                                                                                               10U                          700H x 625W x 240D mm
                                                                                                                               16U                          1200H x 700W x 350D mm
                                                                                                                               29U                          1800H x 700W x 350D mm
                                                                                                                               SP1X Anc Cab                 250H x 405W x 145D mm
                                                                                                                               SP8X Anc Cab                 418H x 515W x 170D mm
                                                                                                 Weight                        SP1X                         10 kg
                                                                                                                               SP8X                         20 kg
                                                                                                                               SP16X                        35 kg
            FireFinder SP16X                             FireFinder Rack Panels                                                10U                          40 kg
  Conventional / Intelligent Control Panel        Conventional / Intelligent Control Panel                                     16U                          90 kg
                                                                                                                               29U                          130 kg
                                                                                                                               SP1X Anc Cab                 3 kg
                                                                                                                               SP8X Anc Cab                 5 kg


AUS / PAGE 18                     CONTACT AMPAC                                  HOME        CONTENTS                 SEARCH   ZOOM            PRINT        EXIT
   CONTROL PANELS FIREFINDER Conventional AS4428



                                                                                   FireFinder Conventional Control Panel
                                                                                   SP1X 16 Zone                                                        8550-1150
                                                                                   SP1X 16 Zone EV20+Mic 5.6A                                          8550-1450
                                                                                   SP1X 16 Zone EV40+Mic 5.6A                                          8550-1430
                                                                                   SP8X 16 Zone 5.6A                                                   8550-4150
                                                                                   SP8X 16 Zone EV40+Mic 5.6A                                          8550-4450
                                                                                   SP8X 16 Zone EV60+Mic 5.6A                                          8550-4460
                                                                                   SP8X 16 Zone EV120+Mic 18A                                          8550-4480
                                                                                   SP16X 16 Zone 5.6A                                                  8550-5150
                                                                                   10U 16 Zone 5.6A                                                    8550-6150
                                                                                   16U 16 Zone 5.6A                                                    8550-6250
                                                                                   29U 16 Zone 5.6A                                                    8550-6350
                                                                                   SP1X Ancillary Cabinet                                              8510-9003
                                                                                   SP8X Ancillary Cabinet                                              8510-9010
                                                                                   SP1X Surround                                                       ENC1798-F
                                                                                   SP8X Surround                                                        158-0033
            FireFinder SP1X                         FireFinder SP8X
                                                                                   SP16X Surround                                                      ENC2844-F
       Conventional Control Panel              Conventional Control Panel
                                                                                   SP1X+Ancillary Cabinet Surround                                     ENC1797-F
                                                                                   SP8X+Ancillary Cabinet Surround                                      158-0027

                                                                                 Note:
                                                                                 All panels have glazed outer doors
                                                                                 Additional 16 Zone and Loop Add-On Kits can be fitted




           FireFinder SP16X                      FireFinder Rack Panels
       Conventional Control Panel              Conventional Control Panel




AUS / PAGE 19                  CONTACT AMPAC                          HOME   CONTENTS             SEARCH             ZOOM               PRINT   EXIT
   CONTROL PANELS FIREFINDER Intelligent AS4428



                                                                                        FireFinder Intelligent Control Panel
                                                                                        SP1X 1 Loop                                                         8550-1100
                                                                                        SP1X 1 Loop EV20+Mic 5.6A                                           8550-1400
                                                                                        SP1X 1 Loop EV40+Mic 5.6A                                           8550-1440
                                                                                        SP8X 1 Loop 5.6A                                                    8550-4100
                                                                                        SP8X 1 Loop EV40+Mic 5.6A                                           8550-4400
                                                                                        SP8X 1 Loop EV60+Mic 5.6A                                           8550-4470
                                                                                        SP8X 1 Loop EV120+Mic 18A                                           8550-4490
                                                                                        SP16X 1 Loop 5.6A                                                   8550-5100
                                                                                        10U 1 Loop 5.6A                                                     8550-6100
                                                                                        16U 1 Loop 5.6A                                                     8550-6200
                                                                                        29U 1 Loop 5.6A                                                     8550-6300
                                                                                        SP1X Ancillary Cabinet                                              8510-9003
                                                                                        SP8X Ancillary Cabinet                                              8510-9010
                                                                                        SP1X Surround                                                       ENC1798-F
                                                                                        SP8X Surround                                                        158-0033
             FireFinder SP1X                             FireFinder SP8X
                                                                                        SP16X Surround                                                      ENC2844-F
        Intelligent Control Panel                   Intelligent Control Panel
                                                                                        SP1X+Ancillary Cabinet Surround                                     ENC1797-F
                                                                                        SP8X+Ancillary Cabinet Surround                                      158-0027

                                                                                      Note:
                                                                                      All panels have glazed outer doors
                                                                                      Additional 16 Zone and Loop Add-On Kits can be fitted




            FireFinder SP16X                         FireFinder Rack Panels
        Intelligent Control Panel                   Intelligent Control Panel




AUS / PAGE 20                       CONTACT AMPAC                          HOME   CONTENTS             SEARCH              ZOOM              PRINT   EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           Dot Matrix Panel Printer

                           ❚   The dot matrix printer provides hardcopy activity report
                           ❚   Alarms, faults, isolates and system logs may be printed                   Voltage                                        5 VDC
                                                                                                         Quiescent current                              1A @ 5 VDC
                           ❚   3 colour status LED
                                                                                                         Character size                                 5 x 7 dots
                           ❚   Self test mode                                                            Operating temperature                          -5°C to +55°C (no icing)
                           ❚   Easy maintenance for replaceable ribbon cassette and paper roll           Relative humidity                              25 to 95% (non condensing)
                                                                                                         Weight                                         380 grams

                                                                                                          Dot Matrix Panel Printer                                            159-0110
                                                                                                          Paper – 10 rolls                                                     MIS1981
                                                                                                          Ribbon                                                               MIS1982




                           SmartTerminal Repeater

                           The SmartTerminal Repeater is an LCD annunciator designed to remotely
                           display the status and provide control of the FireFinder Fire Alarm Control   Voltage                                        24 VDC
                                                                                                         Quiescent current (backlight/buzzer off )       12.4 mA
                           Panel.
                                                                                                         Max current (backlight/buzzer on)              44 mA
                                                                                                         Max distance from main panel                   1.2 km
                           ❚   Connects to a Communication Driver Board inside the FireFinder            Auxiliary output (monitored)                   27 VDC 500 mA
                               Control Panel                                                             Operating temperature                          -5°C to +55°C (no icing)
                           ❚   4 line by 40 character LCD with backlight and navigation keys UP/         Relative humidity                              25 to 95% (non condensing)
                               DOWN keys allow the SmartTerminal to be used for FACP operation           Size       SmartTerminal Repeater              300H x 360W x 100Dmm
                               and interrogation                                                                    SmartTerminal Slimline Repeater     195H x 324W x 52Dmm
                           ❚   Buzzer and system Reset                                                   Weight SmartTerminal Repeater                  2.5 kg
                           ❚   Flush or surface mountable enclosure                                                 SmartTerminal Slimline Repeater     1 kg
                           ❚   Controls have tactile and audible feedback of operation
                                                                                                          SmartTerminal Slimline Repeater without PSU                        4350-0003
                           ❚   All terminals cater for 2.5mm cables                                       Mounting Kit                                                       4210-0002
                           ❚   Stand alone power supply capabilities                                      Communication Driver Kit                                            159-0129
                           ❚   Flush mount kit available (Gyprock toggel fixings)




AUS / PAGE 21       CONTACT AMPAC                                HOME               CONTENTS             SEARCH             ZOOM             PRINT             EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                            Network Interface Card (NIC) – 2 Wire Network

                            ❚   The NIC gives the FireFinder network capabilities via the RS422
                                communications port                                                         Voltage                                       24 VDC
                                                                                                            Quiescent Current                             65 mA
                            ❚   Provides an additional RS232 communications port when connected
                                                                                                            Available Ports                               RS422 – network
                                to Controller Interface Card (CIC)                                                                                        RS232 – serial comms
                            ❚   High level interface for Building Management or ModBus protocol for         Max distance (between NICs)                   1.2km
                                SmartGraphics and PLCs                                                      Cable requirements                            RS422 – 2 pair twisted/screened
                            ❚   The NIC can be isolated from other network devices                                                                        RS232 – 1 pair twisted/screened
                            ❚   Loop In/Loop Out for easy installation                                      Operating temperature                         -5°C to +55°C (no icing)
                NEW                                                                                         Relative humidity                             0 to 95% (non condensing)
                                                                                                            Weight                                        225 grams

                                                                                                             Network Interface Card – NIC (2 wire) NZ4512
                                                                                                             SP1X                                                                 159-0258
                                                                                                             SP8X                                                                 159-0259
                                                                                                             SP16X/Rack                                                           159-0260
                                                                                                             Add-On Kit                                                          4310-0079




                            High Level Interface Expander or Port Expander Board

                            The High Level Interface Expander provides the ability for the FireFinder
                            Fire Alarm Control Panels (FACP’s) to support a range of high level interface   Supply Voltage                                27VDC
                                                                                                            Quiescent current                             7.5ma
                            options. The physical interface between the FACP and equipment
                                                                                                            Max No. HLIE per FACP controller              3
                            can be RS232 or RS485.                                                          Size                                          155 L x 72.5 W x 20 D mm
                                                                                                            Ports                                         RS232           RS485
                            Typical applications where the HLI Expander is used are:                        Max Distance                                  15m             1.2kms
                                                                                                            Cabling                                       Multi-core      1 twisted pair +
                            ❚   Building Management
                                                                                                                                                          cable+shield shield
                            ❚   Paging system
                            ❚   Nurse Call Systems                                                           FireFinder High Level Interface Expander – Factory Fitted Inside Panel 159-0268
                            ❚   EV3000                                                                       FireFinder High Level Interface Expander – Add-On Kit                 4310-0080
                            ❚   SmartGraphics
                            ❚   MODBUS




AUS / PAGE 22         CONTACT AMPAC                                HOME                CONTENTS             SEARCH              ZOOM            PRINT            EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           Analogue Loop Upgrade Kit

                           ❚   This kit adds an intelligent analogue loop to the FireFinder
                               Control Panel                                                          Voltage                                   24 VDC
                                                                                                      Quiescent current                         40 mA
                           ❚   For an odd numbered loop upgrade the kit consists of an I/O CPU
                                                                                                      Loop current                              250 mA max.
                               module, cable and termination card                                     Operating temperature                     -5°C to +55°C (no icing)
                           ❚   An even numbered loop upgrade consists of an I/O CPU module            Relative humidity                         0 to 95% (non condensing)
                               and cable                                                              Weight                                    200 grams

                                                                                                       1 Loop Upgrade Kit – even numbered loop SP1X                   159-0001
                                                                                                       1 Loop Upgrade Kit and processor – odd numbered loop SP1X      159-0003
                                                                                                       Even No. Loop SP16X/Rack                                       159-0002
                                                                                                       Even No. Loop SP8                                              159-0046
                                                                                                       Odd No. Loop SP16X/Rack                                        159-0004




                           Module Expansion Kit for Modules (5–8)

                           ❚   Expands the capacity of the FireFinder to accommodate a further four
                               loops, 64 conventional zones, four I/O modules or any combination of   Voltage                                   24 VDC
                                                                                                      Quiescent current                         5 mA
                               the above
                                                                                                      Operating temperature                     -5°C to +55°C (no icing)
                           ❚   Requires a main controller board                                       Relative humidity                         0 to 95% (non condensing)
                                                                                                      Weight                                    110 grams
                           Note: Other expansion module kits are available with 16AZF/Loop/or I/O
                                 modules pre-fitted to suit. Consult your Customer Service office for     SP8X Loop Module Expansion Kit                                 159-0112
                                 more details.                                                         SP16X/Rack Loop Module Expansion Kit                           159-0022




AUS / PAGE 23       CONTACT AMPAC                                 HOME               CONTENTS         SEARCH           ZOOM            PRINT           EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           8 Way Serial Relay Output Board

                           ❚   Each serial relay output board offers 8 voltage free relay outputs, each
                               rated at 5 amps, 24 VDC                                                     Voltage                                    24 VDC
                                                                                                           Quiescent current                          5 mA
                           ❚   Each relay has a single normally open/close volt-free contact extended
                                                                                                           Relay output current                       5 Amps at 24 VDC
                               to a wire-protected screw terminal                                          Operating temperature                      -5°C to +55°C (no icing)
                           ❚   The serial 8-way relay is driven directly from the main controller board    Relative humidity                          0 to 95% (non condensing)
                                                                                                           Weight                                     190 grams

                                                                                                            Rack 8 Way Serial Relay Output Board                              159-0072
                                                                                                            SPX 8 Way Serial Relay Output Board                               159-0079




                           4 Plus 4 Bell Monitor Board

                           ❚   The 4 Plus 4 Bell Monitor has screw terminals for 4 voltage free contacts
                               and 4 switched 24V DC sounder outputs                                       Voltage                                    24 VDC
                                                                                                           Quiescent current                          20 mA
                           ❚   The outputs are programmable and monitored for open or short circuit
                                                                                                           Relay output current                       1 Amp at 24 VDC
                           ❚   The board connects directly to the main controller board                    Sounder output current                     1 Amp each
                                                                                                           Capacity                                   8 boards per main controller
                                                                                                           Operating temperature                      -5°C to +55°C (no icing)
                                                                                                           Relative humidity                          0 to 95% (non condensing)
                                                                                                           Weight                                     250 grams

                                                                                                            4 Plus 4 Bell Monitor Board                                       159-0069




AUS / PAGE 24       CONTACT AMPAC                                 HOME              CONTENTS               SEARCH             ZOOM            PRINT          EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           8-Way 5A Relay

                           ❚   Each upgrade panel add-on offers 8 voltage free relay outputs. E ach
                               output is rated at 5 amps, 24 VDC                                        Voltage                            24 VDC
                                                                                                        Quiescent current                  5 mA (Serial Relay Board)
                           ❚   Each relay has a single normally open/close volt-free contact extended
                                                                                                        Operating temperature              -5°C to 55°C
                               to a wire-protected screw terminal                                       Humidity                           0 to 95% relative humidity
                           ❚   The standard 8-way relay upgrade requires spare capacity available on    Weight                             190 grams
                               a 128/128 I/O and 16/16 I/O module
                                                                                                         SPX 8-Way 5A O/P Relay                                    159-0013
                                                                                                         Rack 8-Way 5A O/P Relay                                   159-0015




AUS / PAGE 25       CONTACT AMPAC                                HOME              CONTENTS             SEARCH           ZOOM      PRINT          EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           8 Way Bell Monitor Board

                           ❚   The 8-Way Bell Monitor has 8 switched 24V DC sounder outputs
                           ❚   The outputs are programmable and monitored for open or short circuit       Voltage                                     24 VDC
                                                                                                          Quiescent current                           20 mA
                           ❚   The board connects directly to the main controller board
                                                                                                          Max sounder output current                  1 Amp each
                                                                                                          Max output current                          4 Amps per board
                                                                                                          Operating temperature                       -5°C to +55°C (no icing)
                                                                                                          Relative humidity                           0 to 95% (non condensing)
                                                                                                          Weight                                      250 grams

                                                                                                           8 Way Bell Monitor Board                                         159-0071




                           16 Way Conventional Zone Card

                           ❚   Adds 16 conventional Alarm Zone Circuits
                           ❚   Kit consists of an I/O CPU module, cable and 16 zone termination card      Voltage                                     24 VDC
                                                                                                          Quiescent current                           145 mA
                           ❚   Supports up to 40 conventional detectors (Series 60, Series 65 or Orbis)
                                                                                                          Operating temperature                       -5°C to +55°C (no icing)
                               per zone                                                                   Relative humidity                           0 to 95% (non condensing)
                           ❚   Fixed 3K3 End-Of-Line device                                               Weight                                      185 grams
                           ❚   Supports Ampac NZ detector models
                                                                                                           SP8X/SP16X 16 Way Conventional Zone Card                         159-0005
                                                                                                           Rack 16 Way Conventional Zone Card                               159-0006




AUS / PAGE 26       CONTACT AMPAC                                HOME               CONTENTS              SEARCH            ZOOM           PRINT             EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           16 Opto Inputs

                           ❚   The Opto Input panel add-on provides 16 programmable electrically
                               isolated inputs to the FACP                                           Voltage                          24 VDC
                                                                                                     Quiescent current                5 mA
                           ❚   The input from a third party source should be a volt-free contact
                                                                                                     Operating temperature            -5°C to 55°C
                           ❚   This upgrade requires spare capacity available on a 128/128 I/O and   Humidity                         0 to 95% relative humidity
                               16/16 I/O Interconnect Module                                         Weight                           185 grams

                                                                                                      SP 16 Opto Input                                    159-0010
                                                                                                      Rack 16 Opto Input                                  159-0011




                           Modem

                           ❚   The modem allows a remote access to FireFinder
                           ❚   Configuration and application software can be uploaded or              Voltage                          27 VDC
                                                                                                     Data transfer rate               9600 baud max
                               downloaded via the modem
                                                                                                     Comms to FACP                    RS 232
                           ❚   Wireless Modem requires available signal from appropriate network     Operating temperature            -5°C to 55°C
                           ❚   All modems are AUSTEL approved                                        Humidity                         0 to 95% relative humidity
                           ❚   Great tool to provide remote support                                  Weight                           SP & Rack: 1kg
                                                                                                                                      Wireless: 5kg

                                                                                                      SPX Modem                                           159-0033
                                                                                                      Rack Modem                                          159-0065
                                                                                                      Wireless Modem                                      159-0068




AUS / PAGE 27       CONTACT AMPAC                               HOME              CONTENTS           SEARCH            ZOOM   PRINT      EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           Fire Fan Module AS

                           Each Fire Fan Module houses the control and indication of up to four (4)
                           fire fans and a single control/indication for plant trip reset.                  Operating Voltage                             27VDC
                                                                                                           Dimensions:
                                                                                                           Controller Card                               Fits standard Panel Cut-Out
                           A hard-wired version of a fire fan module consists of a Fire Fan Control         Termination Board                             155mm x 72mm
                           Card and Termination Board. Field wiring is terminated to the termination       System Capacity:
                           board at the FACP.                                                              FireFinder                                    15 Maximum
                                                                                                           LoopSense                                     15 Maximum
                           A loop-driven version is also available and in thisconfiguration only the Fire   ZoneSense Plus                                1 Maximum
                           Fan Control Card would be required. Field wiring will terminate to address      Contact Rating                                32 @ 24VDC
                           input/output devices that operate on the addressable loop.                      Approval                                      SSL, C-TICK

                                                                                                            Hard Wired                                                      4310-0021
                                                                                                            Loop Driven                                                     4310-0071
                           ❚   Four (4) Controls per Module                                                 Slip in Label Template                                           LAB1486
                           ❚   Status indication for Run / Fault / Stop                                     Switch and Indicator (Separate Add-On Kit)                      4310-0030
                           ❚   Controls for ON / Auto / Off
                           ❚   Audible and visual feedback of button press
                           ❚   Built in Plant Trip Reset
                           ❚   Easy to Change function of module
                           ❚   Available in Hardware or loop driven versions
                           ❚   Communicates with FACP via RS485 communication port
                           ❚   Where applicable all terminals cater for 2.5mm² cables
                           ❚   Suitable for use with the FireFinder range of panels, LoopSense and
                               and ZoneSense PLUS Fire Alarm Control Panels




AUS / PAGE 28       CONTACT AMPAC                                 HOME              CONTENTS               SEARCH              ZOOM            PRINT        EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           Agent Release System AS4214

                           The Agent Release System comprises of the Main Control Card,
                           Termination Board and Local Control Stations. In addition a yellow Manual      Pressure Switch Input                  Monitored Input
                                                                                                          Low Pressure Switch Input              Monitored Input
                           Call Point can be supplied to fit to the main Fire Alarm Control Panel (FACP)
                                                                                                          Interlock Input                        Monitored Input
                           (This is a requirement of AS4214 Agent Release Systems)                        Gas Fired Output                       Volt Free Changeover
                                                                                                                                                 1A@24VDC
                           The Agent Release System can be configured to operate                           System Inoperative Output              Volt Free Changeover
                           in a single group or dual group mode.                                                                                 1A@24VDC
                                                                                                          Stage 1 Output                         Monitored
                           ❚   Controls and Monitors Agent Release System                                 Stage 2 Output                         Monitored
                           ❚   Outputs for Warning Signs and activation devices                           Release Initial Agent Output           Monitored current limited
                           ❚   Inputs for signals from pressure switches & valves                                                                2A max
                                                                                                          Release Reserve Agent Output           Monitored current limited
                           ❚   Serial connection to Agent Release Local Control Station (LCS)
                                                                                                                                                 2A max
                           ❚   Programmable via the ZoneSense PLUS front panel
                           ❚   Programmable via ConfigManager for the FireFinder range of panels            Agent Release Kit                                       4310-0010
                           ❚   Programmable via LoopMaster for the LoopSense range of panels




                           Local Control Station AS4214

                           A maximum of 8 LCS's can be connected remote to the panel. An operator
                           may manually release or inhibit release from any of these LCS's.               Inhibit Agent Release                  Push button hinged cover
                                                                                                          Manual release                         MCP with hinged cover
                           ❚   RS485 serial connection from the FireFinder FACP to the Agent Release
                                                                                                           Local Control Station                                   4310-0019
                               Local Control Station (LCS)
                           ❚   A 20mm knock out is provided in the top and bottom of the LCS metal
                               enclosure




AUS / PAGE 29       CONTACT AMPAC                                HOME              CONTENTS               SEARCH               ZOOM      PRINT      EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           8 Way Switch and Indicator Card

                           ❚   8 x Push Button On / Off switches
                           ❚   8 x LED display of the On / Off condition                             Voltage                              24VDC
                                                                                                    Quiescent Current                    3.6mA
                           ❚   Controls and Monitors solenoid test switches, manual shutdowns and
                                                                                                    Max Current                          8mA
                               etc.                                                                 Operating Temperature                -5°C - 55°C
                           ❚   Switches may be mapped to relays using an AMPAC relay board          Humidity                             0 to 95% relative humidity
                               (4310-0050)                                                          Weight                               100grams
                           ❚   Programmable via the ZoneSense PLUS front panel.
                           ❚   Programmable via ConfigManager for the FireFinder range of panels      Switch and Indicator Card                                  4310-0030
                           ❚   Programmable via LoopMaster for the LoopSense range of panels




AUS / PAGE 30       CONTACT AMPAC                              HOME             CONTENTS            SEARCH            ZOOM       PRINT          EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           Panel Mounted LED Indicators

                           ❚   Provide flexibility to include additional LED indicators to the FireFinder
                               SP1X and SP8X                                                               Voltage                                      27 VDC
                                                                                                           Quiescent current                            30 mA
                           ❚   Available in three versions:
                                                                                                           Max current                                  40 mA
                               – 32 zone alarm only indication (red)                                       Operating temperature                        -5°C to +55°C (no icing)
                               – 16 zone alarm/fault indication (red/amber)                                Relative humidity                            0 to 95% (non condensing)
                               – 32 zone general indication (amber)                                        Weight                                       100 grams
                           ❚   Serial connection to the FireFinder panel
                           ❚   Simple clip installation
                           ❚   Indicators remain illuminated until reset by the panel                       FireFinder SP1X 32 Zone Alarm Only Indication (Red)               159-0106
                           ❚   Indicators are tested by the FireFinder panel’s lamp test control            FireFinder SP8X 32 Zone Alarm Only Indication (Red)               159-0089

                                                                                                            FireFinder SP1X 16 Zone Alarm/Fault Indication (Red/Amber)        159-0107
                                                                                                            FireFinder SP8X 16 Zone Alarm/Fault Indication (Red/Amber)        159-0108

                                                                                                            FireFinder SP1X 32 Zone General Indication (Amber)                159-0123
                                                                                                            FireFinder SP8X 32 Zone General Indication (Amber)                159-0124




AUS / PAGE 31       CONTACT AMPAC                                 HOME               CONTENTS              SEARCH            ZOOM              PRINT              EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                                        Remote Mounted LED Indicators

                                        ❚   The remote LED indicator boards provide facilities to mimic the
                                            FireFinder zone LEDs and switches                                       Voltage                                   27 VDC
                                                                                                                    Quiescent current                         8 mA max
                                        ❚   Connects to the RS485 communications bus via the controller interface
                                                                                                                    Max current                               100 mA
                                            card                                                                    Communication mode                        RS485
                                        ❚   Allows the custom design of geographic site layout mimics               Baud rate                                 19200 max
                                        ❚   Each termination board connects up to 32 zone LEDs – 31 boards          Communication cable                       1 x pair twisted and screened
                                            maximum – total 992 zone indications                                    No. of boards                             31 max
                                                                                                                    No. of zones                              992 zones max
    FireFinder LED Mimic Driver                                                                                     Buzzer external max current               20 mA
                                                                                                                    On board status indication                Power on – green
                                                                                                                                                              Normal – green
                                                                                                                                                              Fault – yellow
                                                                                                                    Common inputs                             Reset
                                                                                                                                                              Lamp test
                                                                                                                                                              Buzzer mute
                                                                                                                                                              Bell isolate
                                                                                                                                                              Manual evacuate
                                                                                                                    Operating temperature                     -5°C to +55°C (no icing)
                                                                                                                    Relative humidity                         0 to 95% (non condensing)

                                                                                                                     FireFinder LED Mimic Driver                                    302-7150
                   Mimic Output Termination Board
                                                                                                                     Mimic Output Termination Board                            BRD85MOTB1-A
                                                                                                                     Remote Expansion LED Board                                     302-7330




                     Remote Expansion LED Board




AUS / PAGE 32                     CONTACT AMPAC                              HOME             CONTENTS              SEARCH             ZOOM           PRINT          EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           Fibre Optic Network Interface

                           The fibre optic network interface kit offers the user a method of
                           interconnecting two (2) or more networked FireFinder Fire Alarm Control       Supply Voltage                                24 VDC
                                                                                                         Quiescent Current                             80 mA @ 24 VDC
                           Panels (FACP) using fibre optic cable as an alternative to copper wire. Each
                                                                                                         Optical Connector                             ST standard
                           FACP will require a kit. Each kit comprises of 2 modem interfaces plus        Ports Available                               RS422/RS485
                           cables.                                                                       Size (mm)                                     104D x 104W x 25H
                                                                                                         Weight                                        280g
                           ❚   4 versions available to suit your cabling scheme on site                  Operating Temperature                         -20°C to +75°C
                           ❚   Redundant loop integrity (same as copper)                                 Humidity                                      0 to 95% relative,
                           ❚   A network interface card is still required at each FACP node                                                            non-condensing
                           ❚   Maximum distance using ‘Multimode’ (between nodes) up to 5km;
                               using Single Mode 50km                                                     Item                                        Max Distance          Code
                                                                                                                                                      between Nodes
                                                                                                          FireFinder Fibre Optic Multimode 2 core     5km max           159-0251
                                                                                                          FireFinder Fibre Optic Multimode 1 core     5km max           159-0252
                                                                                                          FireFinder Fibre Optic Single mode 2 core   50km max          159-0253
                                                                                                          FireFinder Fibre Optic Single mode 1 core   50km max          159-0254




AUS / PAGE 33       CONTACT AMPAC                                HOME              CONTENTS              SEARCH             ZOOM             PRINT        EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           SmartGraphics

                           Ampac’s SmartGraphics System unleashes the full power of FireFinder              Maps can be modified on site
                           by creating a robust and versatile hub for controlling your fire                  Trained graphics operators will be able to make modification to maps
                           management system. This graphics based system delivers functionality             easily. Trained operators with the licence to modify maps will have the
                           and clarity in an integrated unit. Flexible and intuitive in its design,         tools and software to execute these changes.
                           SmartGraphics puts command of the system that you want at your
                                                                                                            Separate logs for alarm, fault and isolate conditions
                           fingertips. Access the smart solution in fire systems with Ampac.
                                                                                                            SmartGraphics provides the operator with historical data on the activity
                           The heart of the system                                                          of the fire alarm system. To facilitate the interrogation of data, alarm, fault
                           At the heart of any building management system lies the need for a hub           and isolate events are stored in separate logs. These logs can be printed on
                           – a control point for the fire system that protects the building. The Ampac       demand.
                           SmartGraphics System has been designed as that control point – a flexible,
                                                                                                            Site-specific information can be user defined for each map
                           secure hub capable of displaying crucial information with speed in a low-
                                                                                                            Notes can be added to each map giving the operator or fire brigade
                           cost graphically-based format.
                                                                                                            in attendance specific information about the area (eg list of hazardous
                           The result? Faster emergency response. The ability to maintain and access        chemicals).
                           the building’s fire alarm system (or that of your client) remotely and to
                                                                                                            Simple installation
                           modify, maintain and update the site specific information as required.
                                                                                                            SmartGraphics is installed off a CDROM. Within minutes your
                           The Ampac SmartGraphics System offers an optional touch screen user
                                                                                                            SmartGraphics will be up and running. Operator must be licenced to use
                           interface and is the perfect partner for the Ampac FireFinder.
                                                                                                            this software. A security key fitted to the computer is supplied with each
                           Password Protected                                                               licence purchased.
                           A three-tier password access to SmartGraphics determines what features
                                                                                                            Based on an industry standard platform
                           an operator can use. Level One (does not require password) allows
                                                                                                            ModBus protocol between SmartGraphics and FireFinderTM fire alarm
                           operator to browse through maps, acknowledge alarms and print maps.
                                                                                                            systems. This mode and format of transmission has been adopted because
                           Level Two gives operator Level One privileges plus access to system
                                                                                                            of its worldwide popularity in graphics based systems.
                           information, event logs, and zone/sensor test/isolated facilities. Level Three
                           gives operator Level One and Two privileges plus access to tools (password       Templates and symbols can be user defined
                           administration) and the ability to shutdown SmartGraphics.                       Trained graphics operators will have the ability to create a library of
                                                                                                            templates. These can be used as a foundation to create new maps for
                           Faster Emergency Response
                                                                                                            different sites. Symbols may be customised in shape, colour and size to fit
                           Any change in the status of a device is immediately displayed graphically
                                                                                                            demands of a variety of buildings.
                           on the monitor. In the event of an alarm, the SmartGraphics may be
                           configured to automatically print a map showing the location of the
                           incipient fire.
                           Conduct alarm and fault testing including isolating zones or devices
                           SmartGraphics allows an operator to conduct testing of the fire system.
                           System integrity and functionality of every zone and sensors can be tested.
                           Zones and sensors can also be isolated.



AUS / PAGE 34       CONTACT AMPAC                                 HOME               CONTENTS               SEARCH            ZOOM             PRINT           EXIT
   CONTROL PANELS FIREFINDER Conventional / Intelligent



                           SmartGraphics

                           ❚   Faster emergency response
                           ❚   Ability to conduct alarm and fault test including isolating zones or   Environment                                         PC based system
                                                                                                      PC Specifications                                    Pentium 3, 1Ghz processor,
                               devices
                                                                                                                                                          1GB hardrive space,
                           ❚   Separate logs for alarm, fault and isolate conditions
                                                                                                                                                          CDROM, and, parallel and
                           ❚   Password protected                                                                                                         serial ports
                           ❚   Site-specific information can be user-defined for each map               Monitor                                             17” or larger recommended
                           ❚   Supports multiple SmartGraphic systems and users                       Communications                                      RS232/RS485
                           ❚   Simple installation                                                    Baud rate                                           9600 to 38400
                           ❚   Based on “ModBus” protocol which is an industry-standard platform      Max distance                                        RS232:15mRS485: 1200m
                           ❚   Maps can be modified on site
                           ❚   Templates and symbols can be user-defined                                FireFinder SmartGraphics – License Package Only                         154-0073
                           ❚   Multiple communication protocol can be used-RS232, RS485, TCP/IP        FireFinder SmartGraphics – Complete System Package                      154-0074

                                                                                                       The cost of an Ampac SmartGraphics system is largely based upon the final number
                                                                                                       of Maps involved and the number of devices monitored and controlled or reported
                                                                                                       upon. Speak to your local Ampac office for a no obligation budgetary estimate.
                                                                                                       We are happy to deliver customised one on one SmartGraphics presentations to
                                                                                                       building managers or consultants to provide insight and knowledge of the solution
                                                                                                       features and its benefits.




AUS / PAGE 35       CONTACT AMPAC                                HOME              CONTENTS           SEARCH             ZOOM              PRINT             EXIT
   EMERGENCY WARNING SYSTEMS




Emergency Warning Systems


The Ampac EV3000 Occupant Warning and Intercom System is designed for the
purpose of enabling the orderly evacuation of occupants, from a building or structure,
in the event of an emergency.

The system comprises of two (2) sub-systems. The first being the Occupant Warning
System (OWS) and the other the Occupant Intercom System (OIS). While the Warning
and Intercom System have separate controls, they coexist in a panel that is logically
presented and aesthetically pleasing.

The Occupant Warning System makes use of speakers strategically placed around the
site, to broadcast ALERT, and/or EVACUATION signals or public address announcements.
The OWS may be automatically initiated or manually operated. When not used in an
emergency situation, the EV3000 can broadcast background music and/or general
paging announcements.

The Occupant Intercom System (OIS) consists of front panel control at the Emergency
Control Panel (ECP) and Warden Intercom Phones (WIP) that are strategically placed
throughout the building. Communication is only possible between the WIP and ECP.

For larger sites, multiple control panels may be networked.




AUS / PAGE 36                  CONTACT AMPAC                                 HOME        CONTENTS   SEARCH   ZOOM   PRINT   EXIT
    EMERGENCY WARNING SYSTEMS




Emergency Warning Systems


❚   Modular system design – can be easily customised to meet special requirements
❚   Discrete front panel control – ‘natural’ style layout easy to locate zones
❚   Amplifiers available: 40, 120, 240 & 480-watts – choice of amplifiers to suit your need
❚   Visual output for hearing impaired or noisy environments
❚   Common or individual fire alarm inputs – an “all call” or staged evacuation may be
    configured
❚   2-wire Warden Intercom Phones (WIP) – monitored for open and short circuit
❚   Common or zoned background music inputs – non-emergency input gives EV3000
    the flexibility to fit most applications including shopping centres, hospitals, etc
❚   Monitoring of speaker circuits – monitoring for short or open circuit
❚   Monitoring of Visual Warning indicators – monitoring for short or open circuit
❚   Automatic volume control incorporating ambient noise sensing microphone – ideal
    for applications where the ambient noise levels are different at various times of day
❚   Fail safe volume override output – used as a control to shutdown all non-emergency
    facilities offered by the EV3000 and to override attenuated volume controls located
    in the field
❚   Stand-by signal generators – provides 100% backup of emergency tones for greater
    reliability
❚   Stand-by microphone amplifiers – provides 100% backup of emergency public
    address for greater reliability
❚   Automatic changeover to stand-by amplifier – may be configured in the event an
    active amplifier is faulty
❚   Digital paging console – attractive remote paging console with seven (7) segment
    digital display and keypad gives operator quick and easy access to paging zones
❚   Networked system – expands EV3000 features to include master / sub panel
    configuration, and remote paging console
❚   Optic Fibre Interface – the optional Optic Fibre interface allows the EV3000 to be
    networked over optic fi bre cables




AUS / PAGE 37                   CONTACT AMPAC                                 HOME          CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel



                                                                            Mechanical
                                                                            Material                           1.6mm Mild Steel
                                                                            Finish                             Powder Coated Arch White
                                                                            Dimensions                         10U 700H x 625W x 240D mm (SEC P only)
                                                                                                               12U 900H x 650W x 290D mm
                                                                                                               16U 1200H x 700W x 375D mm
                                                                                                               29U 1800H x 700W x 375D mm
                                                                            Approvals                          SSL – AS2220.89
                                                                            Signals                            Compliant with AS1670.4:2004

                                                                            Electrical
                                                                            Power Supply                       6.5, 13, 19.5 or 26 A mps @ 24 VDC
                                                                            Communication                      RS485 @ 9600 bps
                                                                            EWS Zones                          144 max
                                                                            EIS Zones                          288 max
                EV3000 12U                        EV3000 16U                Paging Console                     8 max (recommended)
                                                                            ECP’s                              12 max (recommended)
                                                                            Visual Warning
                                                                            Option 1                           EV3000 Visual Outputs Maximum of 8 pairs per visual circuit
                                                                                                               (for Xenon 208-0011). Not T3 compliant
                                                                            Option 2                           EV3000 Visual Outputs Maximum of 40 pairs per visual circuit
                                                                                                               (for LED 208-0063). T3 compliant
                                                                                                               Note: The LED visual pairs require the Ampac 4210-0031 Visual
                                                                                                               Driver Kit fitted


                                                                              EV3000 Emergency Control Panel
                                                                              12U MECP                                                                           105-0001
                                                                              16U MECP                                                                           105-0002
                                                                              29U MECP                                                                           105-0003
                                                                              29U Double Cabinet MECP                                                            105-0007
                                                                              10U SECP                                                                           105-0004
                                                                              12U SECP                                                                           105-0005
                EV3000 29U                   EV3000 29U Double Rack           16U SECP                                                                           105-0006
                                                                              29U SECP                                                                           105-0009




AUS / PAGE 38                CONTACT AMPAC                       HOME   CONTENTS             SEARCH            ZOOM            PRINT             EXIT
   EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons



                         40 Watt Power Amplifier

                         ❚   A modular power amplifier that is rated at 40 watts
                         ❚   Multi-channel audio input supports Alert tone, Evacuation tone, Public   Voltage                            24 VDC
                                                                                                      Quiescent current                  58mA
                             Address, and background music
                                                                                                      Max current                        3400mA
                         ❚   Continuous monitoring of amplifier and 100 volt speaker circuit           Max output power                   40 Watts
                         ❚   Overload protection with Automatic                                       Output voltage                     100 VAC RMS
                         ❚   Easily plugs into an Ampac EV3000 amplifier frame                         Freq. Response                     150Hz to 12kHz (±1dB)
                         ❚   Can fit up to 8 amplifiers per frame                                       Distortion                         Max 1% at full load
                                                                                                                                         (typical 0.5%)
                                                                                                      Sensitivity                        +5dB <200Kohm balanced)
                                                                                                                                         (1.4VRMS)
                                                                                                      Overload                           100 VRMS + 10%
                                                                                                      Weight                             675 grams

                                                                                                       40 Watt Power Amplifier                               154-0075




                         120 Watt Power Amplifier

                         ❚   A modular power amplifier that is rated at 120 watts
                         ❚   Multi-channel audio input supports Alert tone, Evacuation tone, Public   Voltage                            24 VDC
                                                                                                      Quiescent current                  175mA
                             Address, and background music
                                                                                                      Max current                        8100mA
                         ❚   Continuous monitoring of amplifier and 100 volt speaker circuit           Max output power                   120 Watts
                         ❚   Overload protection with Automatic                                       Output voltage                     100 VAC RMS
                         ❚   Easily plugs into an Ampac EV3000 amplifier frame                         Freq. Response                     210Hz to 14.5kHz (±1dB)
                         ❚   Can fit up to 4 amplifiers per frame                                       Distortion                         < 0.2% at full load
                                                                                                      Signal to Noise                    77 dB
                                                                                                      Overload                           100 VRMS + 10%
                                                                                                      Weight                             1160 grams

                                                                                                       120 Watt Power Amplifier                              154-0077




AUS / PAGE 39      CONTACT AMPAC                               HOME              CONTENTS             SEARCH              ZOOM   PRINT      EXIT
   EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons



                         240 Watt Power Amplifier

                         ❚   24v DC supply
                         ❚   Mother board address strapping (120 address positions)               Voltage                            24 VDC
                                                                                                  Quiescent current                  350mA
                         ❚   Continuous fault monitoring
                                                                                                  Max current                        16200mA
                         ❚   Volume override output                                               Max output power                   240 Watts
                         ❚   Test tone input                                                      Output voltage                     100 VAC RMS
                         ❚   Data selectable 4 channel input (balanced)                           Freq. Response                     210Hz to 14.5kHz (±1dB)
                         ❚   Tone generator synchronisation input                                 Distortion                         < 0.2% at full load
                         ❚   Indication (power on - green, power shutdown - yellow, amp or line   Signal to Noise                    77 dB
                             fault - red, overload - red)                                         Overload                           100 VRMS + 10%
                         ❚   Minimum cable size 2.5mm²                                            Weight                             2320 grams

                                                                                                   240 Watt Power Amplifier                              154-0001




                         480 Watt Power Amplifier

                         ❚   24v DC supply
                         ❚   Mother board address strapping (120 address positions)               Voltage                            24 VDC
                                                                                                  Quiescent current                  700mA
                         ❚   Continuous fault monitoring
                                                                                                  Max current                        32400mA
                         ❚   Volume override output                                               Max output power                   480 Watts
                         ❚   Test tone input                                                      Output voltage                     100 VAC RMS
                         ❚   Data selectable 4 channel input (balanced)                           Freq. Response                     210Hz to 14.5kHz (±1dB)
                         ❚   Tone generator                                                       Distortion                         < 0.2% at full load
                         ❚   Indication (power on - green, power shutdown - yellow, amp or line   Signal to Noise                    77 dB
                             fault - red, overload - red)                                         Overload                           100 VRMS + 10%
                         ❚   Minimum cable size 4mm²                                              Weight                             4640 grams



                                                                                                   480 Watt Power Amplifier                              154-0002




AUS / PAGE 40      CONTACT AMPAC                              HOME              CONTENTS          SEARCH              ZOOM   PRINT      EXIT
   EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons



                         Emergency Alarm Initiating Device (EAID)

                         ❚   Connects to S004 WIP
                         ❚   2 wires for WIP & EAID
                         ❚   Compatible with 219-0015




                                                                                            Emergency Alarm Initiating Device (EAID)                     213-0068




                         Warden Intercom Phone – 2 Wire (S0004)

                         ❚   2 Wire WIP/EAID wiring
                         ❚   High quality WIP audio                                        Operating Voltage                           27 VDC (line driven)
                                                                                           Line Voltage                                On hook - 25 VDC max
                         ❚   Complies with AS4428.4
                                                                                                                                       Off hook - 14 VDC max
                         ❚   Suitable for models manufactured after July 2010              Current draw                                On hook - 5 mA max
                                                                                                                                       Off hook - 35 mA max
                                                                                           Line Impedance                              360 ohm balanced
                                                                                           Line Level                                  0 dB (± 3dB)
                                                                                           Cabling                                     2 wire - 2.5mm² max.
                                                                                           Dimensions                                  215H x 85W x 62D mm
                                                                                           Weight                                      380 grams

                                                                                            Warden Intercom Phone – 2 Wire (S0004)                       219-0015
                                                                                            WIP Enclosure Metal Surface Mounted                          291-0054




AUS / PAGE 41      CONTACT AMPAC                              HOME              CONTENTS   SEARCH              ZOOM           PRINT       EXIT
   EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons



                         Warden Intercom Phone – 3 Wire

                         ❚   The WIP is installed remote to the ECP
                         ❚   Provides intercommunication between users at the WIP and              Operating Voltage                        27 VDC (line driven)
                                                                                                   Line Voltage                             On hook - 25 VDC max
                             Emergency Control Panel
                                                                                                                                            Off hook - 14 VDC max
                         ❚   This feature is only available when the Emergency Warning Intercom    Current draw                             On hook - 5 mA max
                             facility has been incorporated in the control panel                                                            Off hook - 35 mA max
                         ❚   Made of high impact red ABS plastic                                   Line Impedance                           360 ohm balanced
                         ❚   Compatible with most EV3000 systems manufactured before July 2010     Line Level                               0 dB (± 3dB)
                                                                                                   Cabling                                  3 wire - 2.5mm² max.
                                                                                                   Dimensions                               215H x 85W x 62D mm
                                                                                                   Weight                                   380 grams

                                                                                                    Warden Intercom Phone – 3 Wire                            219-0007
                                                                                                    WIP Enclosure Metal Surface Mounted                       291-0054




                         Remote Paging Console

                         ❚   Provides a point to initiate a non-emergency voice announcement via
                             the EV3000                                                            Size                                     80H x 300W x 220D mm
                                                                                                   Supply voltage                           12 VDC
                         ❚   Provides a pre-announcement tone
                                                                                                   Current                                  400 mA
                         ❚   Easy keypad operation to broadcast voice announcements to selected    Communication                            RS 485
                             zones, or group of zones                                              Weight                                   1160 grams
                         ❚   Connects to EV3000 via RS485
                         ❚   Derives power from the EV3000 panel                                    Remote Paging Console                                     154-0005




AUS / PAGE 42      CONTACT AMPAC                             HOME              CONTENTS            SEARCH              ZOOM         PRINT      EXIT
   EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons



                         Fibre Optic Network Interface for EV3000

                         The fibre modem network interface kit offers the user a method of
                         interconnecting two (2) or more EV3000 Emergency Warning and                 Supply Voltage                               12 VDC
                                                                                                      Quiescent Current                            300 mA
                         Intercom System (EWIS) using fibre optic cable as an alternative to copper.
                                                                                                      Input Ports Available                        RS422
                         The modems convert hardwired data and audio, to a common fibre optic                                                       Emergency P.A.
                         compatible output.                                                                                                        Warden Intercom Phone Audio
                                                                                                      Max. Distance                                5 km
                         The fibre optic modems are full duplex and have 4-channels to carry both      Cabling                                      2-core multimode fibre
                         data and two (2) audio signals. Two (2) channels are required – emergency    Fibre Connector                              ST Standard
                         public address and warden intercom audio signals.                            Optical Data
                                                                                                      Wavelength                                   850nm
                                                                                                      Mode                                         Multimode
                                                                                                      Emitter type                                 LED
                                                                                                      Operating Temperature                        0°C to +55°C
                                                                                                      Humidity                                     0 to 95% relative,
                                                                                                                                                   noncondensing
                                                                                                      Size                                         L104 x W144 x D25 mm

                                                                                                       Remote Paging Console                                         154-0005




                          Combined Strobe for EV3000 (Surface Mount)

                          Item pictured is 208-0066 Indoor. The IP65 model uses the deep base to       Combined Strobe for EV3000 (Indoor)                           208-0066
                          achieve an outdoor solution where required.                                  Combined Strobe for EV3000 (IP65 Outdoor)                     208-0065




AUS / PAGE 43      CONTACT AMPAC                              HOME               CONTENTS             SEARCH              ZOOM          PRINT         EXIT
   EMERGENCY WARNING SYSTEMS Speakers



                       Ceiling Speaker – 100mm Recessed

                       ❚   100 mm recessed ceiling speaker
                       ❚   Operates with 100 volt speaker line                             Rated Power                                 5 watts
                                                                                           Line Voltage                                100 Volt
                       ❚   Capacitor fitted for line monitoring
                                                                                           Frequency R esponse                         100 Hz to 20 kHz
                       ❚   Five (5) power output settings                                  SPL                                         96 dB (1 watt @ 0.5m)
                       ❚   Safety cover to protect terminals                               Speaker Tap (watt)                          0.33, 0.66, 1.25, 2.5, 5
                       ❚   Facility to secure field cabling to speaker housing              Cut-out size                                85 mm Diameter
                       ❚   Optional low profile grill available                             Dimensions                                  100 x 105 Hmm
                                                                                           Weight                                      800 grams

                                                                                            Ceiling Speaker – 100mm Recessed                                 218-0008
                                                                                            Low Profile Grill                                                 218-0003




                       Ceiling Speaker – 200mm Recessed

                       ❚   200 mm recessed ceiling speaker
                       ❚   Operates with 100 volt speaker line                             Rated Power                                 5 watts
                                                                                           Line Voltage                                100 Volt
                       ❚   Capacitor fitted for line monitoring
                                                                                           Frequency R esponse                         100 Hz to 20 kHz
                       ❚   Five (5) power output settings                                  SPL                                         96 dB (1 watt @ 0.5m)
                       ❚   Safety cover to protect terminals                               Speaker Tap (watt)                          0.33, 0.66, 1.25, 2.5, 5
                       ❚   Facility to secure field cabling to speaker housing              Cut-out size                                190 mm Diameter
                       ❚   Optional low profile grill available                             Dimensions                                  200 x 75 Hmm
                                                                                           Weight                                      1 kg

                                                                                            Ceiling Speaker – 200mm Recessed                                 218-0009
                                                                                            Low Profile Grill                                                 218-0021




AUS / PAGE 44    CONTACT AMPAC                               HOME               CONTENTS   SEARCH           ZOOM               PRINT       EXIT
   EMERGENCY WARNING SYSTEMS Speakers



                       Ceiling Speaker – 100mm One-Shot

                       ❚   100 mm quick-fit recessed ceiling speaker
                       ❚   Operates with 100 volt speaker line                              Rated Power                                 5 watts
                                                                                            Line Voltage                                100 Volt
                       ❚   Capacitor fitted for line monitoring
                                                                                            Frequency R esponse                         100 Hz to 15 kHz
                       ❚   Five (5) power output settings                                   SPL                                         98 dB (1 watt @ 0.5m)
                       ❚   Safety cover to protect terminals                                Speaker Tap (watt)                          0.33, 0.66, 1.25, 2.5, 5
                       ❚   Facility to secure field cabling to speaker housing               Cut-out size                                140 mm Diameter
                       ❚   Speaker grill incorporated with speaker                          Dimensions                                  155 x 110 Hmm
                                                                                            Weight                                      850 grams

                                                                                             Ceiling Speaker – 100mm One-Shot (White)                         218-0026
                                                                                             Ceiling Speaker – 100mm One-Shot (Black)                         218-0031
                                                                                             Ceiling Speaker – 200mm One-Shot (White)                         218-0032




                       Surface Speaker – 100mm

                       ❚   Custom designed speaker and transformer assembly engineered to
                           meet Australian Fire Evacuation Standards                        Driver                                      100mm (4”) dual cone
                                                                                            Power taps                                  0.33, 0.66, 1.25, 2.5, 5W
                       ❚   High degree of speech intelligibility
                                                                                            SPL 1W @ 1m                                 90dB @ 1kHz (+/- 2dB)
                                                                                            Frequency response                          100Hz-15kHz
                                                                                            Connection                                  4 way terminal block + 22uF
                                                                                                                                        bipolar capacitor

                                                                                             Surface Speaker – 100mm                                          218-0022




AUS / PAGE 45    CONTACT AMPAC                               HOME               CONTENTS    SEARCH           ZOOM            PRINT          EXIT
   EMERGENCY WARNING SYSTEMS High Efficiency Speakers



                        EasyFit Ceiling Speakers

                        ❚   In four useful sizes: 4”, 5”, 6.5”, 8”
                        ❚   Choice of power rating: 5W, 10W, 15W, & 30W
                        ❚   Wide bandwidth for music reproduction
                        ❚   Wide dispersion for speech intelligibility
                        ❚   Simple output-level selection
                        ❚   Easily flush-mounted in ceilings or bulkheads
                        ❚   Dependable rota-clamp fixing system
                        ❚   Blends in with virtually all interiors


                                                           4 Inch 5 Watt               5 Inch 5 Watt                 6 Inch 10 Watt               8 Inch 15 Watt                 8 Inch 30 Watt
                        Driver                             4”                          5”                            6.5”                         8”                             8”
                        Maximum/rated power                8W/5W                       8W/5W                         15W/10W                      22W/15W                        45W/30W
                        Power taps                         5, 2.5, 1.25, 0.66, 0.33W   5, 2.5, 1, 0,5, 0.33W         10, 5, 2.5, 1.25W            15, 10, 5, 2.5, 1.25W          30, 15, 7.5, 3.75W
                        Frequency Range                    100Hz - 15kHz               50Hz - 17kHz                  60Hz - 20kHz                 50Hz - 17kHz                   50Hz - 17kHz
                        Axial sensitivity 1W/1m/1kHz       94dB SPL                    97dB SPL                      91dB SPL                     93dB SPL                       93dB SPL
                        Opening Angle( -6dB)               144° / 93° at 1kHz / 4kHz   170° at 1kHz                  170° at 1kHz                 165° at 1kHz                   100° at 1kHz
                        Ceiling cutout diameter            140mm                       170mm                         195mm                        238mm                          238mm
                        Overall dimensions                 170mm x 110mm               202mm x 90mm                  220mm x 115mm                273mm x 103mm                  273mm x 115mm
                        Safety                             acc to EN 60065             acc to EN 60065               acc to EN 60065              acc to EN 60065                acc to EN 60065




                                                                                                                Ceiling Speaker, Easyfit 5w 4” - EVAC                                       218-0041
                                                                                                                Ceiling Speaker, Easyfit 5w 5” - Brilliant White                            218-0042
                                                                                                                Ceiling Speaker, Easyfit 5w 5” White                                        218-0043
                                                                                                                Ceiling Speaker, Easyfit 10w 6.5”                                           218-0044
                                                                                                                Ceiling Speaker, Easyfit 15w 8” White                                       218-0045
                                                                                                                Ceiling Speaker, Easyfit 30w 8” White                                       218-0046




AUS / PAGE 46     CONTACT AMPAC                              HOME                 CONTENTS                     SEARCH              ZOOM               PRINT               EXIT
   EMERGENCY WARNING SYSTEMS Speakers



                       Horn Speaker – 10 Watt

                       ❚   10 watt Flared horn speaker
                       ❚   Operates with 100 volt speaker line                 Rated Power                       10 watts
                                                                               Line Voltage                      100 Volt
                       ❚   Capacitor fitted for line monitoring
                                                                               Frequency R esponse               250 Hz to 13 kHz
                       ❚   Five (5) power output settings                      SPL                               105 dB (1 watt @ 1m)
                       ❚   High SPL performance                                Speaker Tap (watt)                1.25, 2.5, 5, 7.5, 10
                       ❚   Weatherproof construction                           Dispersion angle                  110°
                       ❚   Mounting bracket supplied                           Material                          UV stabilised plastic
                                                                               IP Rating                         IP65
                                                                               Dimensions                        150 Dia x 190 Dmm
                                                                               Weight                            1.4 kg

                                                                                Horn Speaker – 10 Watt                                 218-0028




                       Horn Speaker – 20 Watt

                       ❚   20 watt Flared horn speaker
                       ❚   Operates with 100 volt speaker line                 Rated Power                       15 watts
                                                                               Line Voltage                      100 Volt
                       ❚   Capacitor fitted for line monitoring
                                                                               Frequency R esponse               270 Hz to13 kHz
                       ❚   Five (5) power output settings                      SPL                               108 dB (1 watt @ 1m)
                       ❚   High SPL performance                                Speaker Tap (watt)                2.5, 5, 7.5, 10, 15, 20
                       ❚   Weatherproof construction                           Dispersion angle                  110°
                       ❚   Mounting bracket supplied                           Material                          UV stabilised plastic
                                                                               IP Rating                         IP65
                                                                               Dimensions                        200 Dia x 290 Dmm
                                                                               Weight                            1.5 kg

                                                                                Horn Speaker – 15 Watt                                 218-0007




AUS / PAGE 47    CONTACT AMPAC                               HOME   CONTENTS   SEARCH            ZOOM    PRINT      EXIT
   EMERGENCY WARNING SYSTEMS High Efficiency Speakers



                        Horn Speaker – 10 Watt / 20 Watt

                        ❚   10W & 20W Models available
                        ❚   IP66 Rated                                                                                                       10 Watt              20 Watt
                                                                                                  Rated input                                100V                 100V
                        ❚   Emergency Evacuation System ready
                                                                                                  Power handling                             10W                  20W
                        ❚   Wide dispersion for speech intelligibility                            Power taps                                 10, 7.5, 5, 2.5,     20, 15. 10,
                        ❚   Screwdriver adjustable power tapping                                                                             1.25                 7.5, 5W
                        ❚   Loop in / Loop out wiring                                             SPL at Rated Power (10W @ 1m)              119 dB               124 dB
                                                                                                  SPL at Rated Power (1W @ 1m)               108 dB               110 dB
                                                                                                  Frequency Range (-10dB)                    300Hz - 13kHz        9kHz
                                                                                                  Dispersion Angle(-6dB)                     140°@1kHz            90°@1kHz
                                                                                                  Weight                                     1.3KG                2.1KG

                                                                                                   Horn Speaker – 10 Watt                                           218-0047
                                                                                                   Horn Speaker – 20 Watt                                           218-0048




                        Speaker Attenuator

                        ❚   Operates in conjunction with an Emergency Warning System (EWS)
                        ❚   Attenuates the sound level of speakers in the circuit during normal   Rated Power                                40 or 100 watts
                                                                                                  Speaker L ine Voltage                      100 Volt
                            operation of the EWS
                                                                                                  Attentuation                               0, 5.7, 9.8, 16, 20, 26.3dB, ∞
                        ❚   7-step attenuator setting including ‘OFF’ position                    Override Relay Operating Voltage           24 VDC
                        ❚   Switched 24 VDC (fail-safe operation) enables attenuation control     Material                                   White UV stabilised plastic
                        ❚   Screw driver terrminals for easy wiring                               Dimensions                                 S uits single gang wall box
                                                                                                                                             (Australian)
                                                                                                  Weight                                     300 g

                                                                                                   Speaker Attenuator – 40 Watt 100V                                225-0002
                                                                                                   Speaker Attenuator – 100 Watt 100V                               225-0003




AUS / PAGE 48     CONTACT AMPAC                                 HOME            CONTENTS          SEARCH             ZOOM            PRINT       EXIT
    DETECTORS




Orbis
Conventional Detectors
Orbis is a range of conventional detectors which has been developed with sophisticated
technology previously only found in intelligent detectors. Orbis is a range with modern
styling and incorporates a mounting base wihich saves installation time.



❚ Automatic drift compensation with DirtAlert® warning
❚ Patented FasTest® which reduces the time taken to test detectors
❚ SensAlert® uses a flashing LED to indicate that the sensor is not operating correctly
❚ StartUp™ for fast commissioning
❚ Attractive and compact design
❚ Electrically compatible with Series 60 and Series 65
❚ Wide voltage and operating temperature ranges
❚ Algorithms for transient rejection
❚ Flashing LED option
❚ 360° visibility of LEDs
❚ Insect resistant




AUS / PAGE 49                   CONTACT AMPAC                                    HOME     CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   DETECTORS    ORBIS Conventional



                          Orbis Optical Smoke Detector

                          The Orbis Optical Smoke Detector works using the well established light
                          scatter principle, however, the sensing technology is radically different   Operating voltage                       8.5 to 33 VDC
                                                                                                     Quiescent current                       65μA at 24 VDC
                          in design from previous optical detectors and significantly reduces false
                                                                                                     Alarm current                           40mA at 24 VDC
                          alarms.                                                                    Remote output                           1.2kΩ to -ve supply
                                                                                                     Size                                    97Dia x 31H mm
                          ❚   Responds well to slow-burning, smouldering fires                        Operating temperature                   -40°C to +70°C (no icing)
                          ❚   Performs well in black and white smoke                                 Relative humidity                       0 to 98% (non condensing)
                          ❚   Extra confirmation of smoke before alarm signal is given                IP rating                               IP23D (EN60529)
                          ❚   Reduced incidence of false alarms                                      Weight                                  75 grams
                          ❚   Sensing chamber keeps out dust and other airborne contaminants
                          ❚   Operates over a broad range of voltages at extremes of temperature      Orbis Optical Smoke Detector                                 201-0512

                          Approvals: AS7240.7/CSIRO




                          Orbis Multisensor Detector

                          The Orbis Multisensor Detector benefits from the same false alarm
                          reduction technology as the optical detector. It is a thermally enhanced   Operating voltage                       8.5 to 33 VDC
                                                                                                     Quiescent current                       65μA at 24 VDC
                          smoke detector and so will not give an alarm from heat alone.
                                                                                                     Alarm current                           40mA at 24 VDC
                                                                                                     Remote output                           1.2kΩ to -ve supply
                          ❚   Responds well to fast-burning, flaming fires                             Size                                    97Dia x 42H mm
                          ❚   Reduced incidence of false alarms                                      Operating temperature                   -40°C to +70°C (no icing)
                          ❚   Increased reliability of detection                                     Relative humidity                       0 to 98% (non condensing)
                          ❚   Sensing chamber keeps out dust and other airborne contaminants         IP rating                               IP23D (EN60529)
                          ❚   Operates over a broad range of voltages at extremes of temperature     Weight                                  80 grams

                          Approvals: AS7240.7/CSIRO                                                   Orbis Multisensor Detector                                   201-0514




AUS / PAGE 50       CONTACT AMPAC                               HOME              CONTENTS           SEARCH            ZOOM          PRINT          EXIT
   DETECTORS    ORBIS Conventional



                          Orbis Heat Detector

                          The Orbis Heat Detector monitors temperature by using a single
                          thermistor network which provides a voltage output proportional to the       Operating voltage                 8.5 to 33 VDC
                                                                                                       Quiescent current                 65μA at 24 VDC
                          external air temperature. There are seven classes of heat detectors in the
                                                                                                       Alarm current                     40mA at 24 VDC
                          Orbis range designed to suit a wide variety of operating conditions.         Remote output                     1.2kΩ to -ve supply
                                                                                                       Size                              97Dia x 36H mm
                          ❚   Can be used for applications where smoke detectors are unsuitable        Operating temperature             -40°C to +70°C (no icing)
                          ❚   Ideal in environments that are dirty or smoky under normal conditions    Relative humidity                 0 to 98% (non condensing)
                          ❚   Reduced incidence of false alarms                                        IP rating                         IP23D (EN60529)
                          ❚   Increased reliability of detection                                       Weight                            70 grams

                          Approvals: AS7240.5/CSIRO                                                     Orbis Heat Detector
                                                                                                        BR/“A” type                                            201-0500
                                                                                                        A2S/“B” type                                           201-0504
                                                                                                        201-0508 CR/“C” type                                   201-0508
                                                                                                        CS/“D” type                                            201-0510




                          TimeSaver Base

                          The TimeSaver Base is a completely new design that provides installers
                          with an open working area with fixing holes shaped to allow a simple          Size                              100Dia x 8H mm
                                                                                                       IP rating                         IP23D (EN60529)
                          mounting procedure.
                                                                                                       Weight                            60 grams

                          ❚   Grouped terminals to make wiring easy
                                                                                                         TimeSaver Base                                        201-0540
                          ❚   Two fixing centres
                          ❚   LED alignment mark
                          ❚   Cable stripping guide
                          ❚   Detector locking mechanism

                          Approvals: AS7240/CSIRO




AUS / PAGE 51       CONTACT AMPAC                               HOME               CONTENTS            SEARCH             ZOOM   PRINT          EXIT
   DETECTORS    ORBIS Conventional



                          TimeSaver LX Base

                          The TimeSaver LX Base has the same design as the standard TimeSaver Base
                          with the addition of a diode. It is used in systems which house active EOL      Size                             100Dia x 8H mm
                                                                                                          Operating temperature            -40°C to +70°C
                          monitoring for head removal.
                                                                                                          Humidity                         0 to 98%
                                                                                                          IP rating                        IP23D (EN60529)
                          ❚   Grouped terminals to make wiring easy                                       Weight                           60 grams
                          ❚   Two fixing centres
                          ❚   LED alignment mark                                                            TimeSaver LX Base                                201-0545
                          ❚   Cable stripping guide
                          ❚   Continuity link for voltage testing of zone wiring prior to commissioning
                          ❚   Detector locking mechanism
                          ❚   Other devices continue to work during unauthorised removal of
                              detectors

                          Approvals: AS7240/CSIRO




                          TimeSaver Relay Base

                          The TimeSaver Relay Base incorporates a single pole voltage-free change-
                          over contact for switching external equipment. When the detector changes        Size                             100Dia x 8H mm
                                                                                                          Operating temperature            -40°C to +70°C
                          to the alarm state, the relay is energised, causing the contact to change
                                                                                                          Humidity                         0 to 98%
                          state. The contact will remain in this condition until the detector is reset.   IP rating                        IP23D (EN60529)
                                                                                                          Weight                           60 grams
                          ❚   Grouped terminals to make wiring easy
                          ❚   Two fixing centres                                                             TimeSaver Relay Base                             201-0539
                          ❚   LED alignment mark
                          ❚   Cable stripping guide
                          ❚   Continuity link for voltage testing of zone wiring prior to commissioning
                          ❚   Detector locking mechanism
                          ❚   Capable of switching up to 30V at 1A

                          Approvals: AS7240/CSIRO




AUS / PAGE 52       CONTACT AMPAC                                HOME              CONTENTS               SEARCH            ZOOM   PRINT         EXIT
   DETECTORS    ORBIS Conventional



                          Ampac Duct Sampling Unit

                          The Ampac Duct Sampling Unit is designed to monitor levels of smoke in       ❚ The cover of the duct smoke detector is monitored to ensure working
                          air ducts operating in air speeds of 0.5 to 20 meters per second.              integrity and if removed, causes a fault to appear at the fire alarm
                                                                                                         control panel
                          The duct smoke detector can be fitted to any wall of a ventilation duct       ❚ Easily accessible wire clamping terminals ensure secure and fast
                          and has two tubes that extend into the duct through punched holes.             termination
                          The perforated sampling tube is placed in the airflow upstream of the         ❚ Clear cover hence the alarm LED on the detector is visible at all times
                          exhaust tube which causes a pressure differential in the duct detector. Air   ❚ Unique self-sealing test port allows the dispensing of test smoke via a
                          is sucked up the sampling tube, across the detector and exhausted back         needle into the duct smoke detector to be tested without the need to
                          into the air duct.                                                             remove the cover
                                                                                                       ❚ Sampling pipes available in 4 lengths
                                                                                                       ❚ Weather resistant enclosure

                                                                                                       Approvals: C-tick, AS1603-13


                                                                                                       Housing                                           Grey - ABS
                                                                                                       Cover                                             Transparent - ABS
                                                                                                       Dimension                                         115H x 340W x 60D mm
                                                                                                       Temperature Range                                 0 to +60°C
                                                                                                       Humidity                                          Up to 85%, no condensation
                                                                                                       Weight                                            5.5 kg
                          Using the 360mm sampling pipe supplied, an air duct of up to 560mm
                          can be monitored. For duct widths greater than 560mm, three other              Duct Sampling Unit fitted with Ampac Orbis Detector Base              214-0052
                          lengths of sampling pipe are available:                                        Sampling Pipe 300 to 760mm                                           214-0060
                                                                                                         Sampling Pipe 760 to 1500mm                                          214-0061
                          1. For duct width 300 to 760mm                                                 Sampling Pipe 1500 to 3000mm                                         214-0062
                          2. For duct width 760 to 1500mm                                                Orbis Photo Optical Head                                             201-0512
                          3. For duct width 1500 to 3000mm                                             Note: The detector head is sold separately to the duct sampling unit

                          ❚ Volt free normally opened or closed non-latching relay contact. Relay
                            energises when detector is in alarm (Available only with Ampac Orbis
                            option)
                          ❚ Both sampling and exhaust pipes are fitted to the back box without
                            the need for tools making installation easier




AUS / PAGE 53       CONTACT AMPAC                               HOME              CONTENTS             SEARCH               ZOOM               PRINT              EXIT
   DETECTORS




XP95
Intelligent Detectors
The XP95 range of intelligent fire detectors is advanced in design, improved in performance
and has unique features that benefit the installer and end user. The range features smoke
detectors (ionisation and optical), standard and high temperature heat detectors and a
multisensor. Beam detectors, flame detectors, manual call points, audio visual signalling
devices, interface units and isolators complete the range. XP95 has a ‘central intelligence’
system where all the decisions are made by the control panel.



Features

❚ Alarm Flag for fast alarm reporting
❚ Alarm Address for fast location of alarm
❚ XPERT card addressing
❚ Electronics-free base
❚ Easy installation
❚ Elegant design
❚ Insect Resistant




AUS / PAGE 54                   CONTACT AMPAC                                    HOME          CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   DETECTORS    XP95 Intelligent



                           XP95 Ionisation Smoke Detector

                           The XP95 Ionisation Smoke Detector uses a low activity radioactive foil
                           to detect fires by irradiating the air in the smoke chambers and causing    Voltage                                   17-28 VDC
                                                                                                      Quiescent current                         280μA at 24 VDC
                           a current flow. If smoke enters the chamber, the current flow is reduced
                                                                                                      Alarm current                             2.0mA at 24 VDC
                           leading to an alarm.                                                       Size inc base                             100Dia x 50H mm
                                                                                                      Operating temperature                     -20°C to +60°C (no icing)
                           ❚   Responds well to fast-burning, flaming fires                             Relative humidity                         0 to 95% (non condensing)
                           ❚   Designed to operate in a variety of environments                       IP rating                                 IP23D
                           ❚   Minimal effects from temperature, humidity, atmospheric pressure        Weight inc base                           161 grams
                           ❚   Well protected against electromagnetic interference over a wide
                               frequency range                                                         XP95 Ionisation Smoke Detector (White)                         201-0002
                                                                                                       XP95 Ionisation Smoke Detector (Black)                         201-0091
                           Approvals: AS1603.2




                           XP95 Optical Smoke Detector

                           The XP95 Optical Smoke Detector works using the light scatter principle
                           and is ideal for applications where slow-burning or smouldering fires are   Voltage                                   17-28 VDC
                                                                                                      Quiescent current                         340μA at 24 VDC
                           likely.
                                                                                                      Alarm current                             4mA at 24 VDC
                                                                                                      Size inc base                             100Dia x 50H mm
                           ❚ Responds well to slow-burning, smouldering fires                          Operating temperature                     -20°C to +60°C (no icing)
                           ❚ Well suited for bedrooms and escape routes                               Relative humidity                         0 to 95% (non condensing)
                           ❚ Unaffected by wind or atmospheric pressure                                IP rating                                 IP23D
                                                                                                      Weight inc base                           157 grams
                           Approvals: AS1603.2                                                        Sensitivity                               0.12db/m

                                                                                                       XP95 Optical Smoke Detector (White)                            201-0003
                                                                                                       XP95 Optical Smoke Detector (Black)                            201-0092




AUS / PAGE 55       CONTACT AMPAC                               HOME              CONTENTS            SEARCH            ZOOM            PRINT         EXIT
   DETECTORS    XP95 Intelligent



                           XP95 Heat Detector

                           The XP95 Heat Detector monitors temperature by using a single
                           thermistor network which provides a count output proportional to the             Voltage                                      17-28 VDC
                                                                                                            Quiescent current                            250-270μA at 24 VDC
                           external air temperature. The XP95 range features two Heat Detectors,
                                                                                                            Alarm current                                2mA at 24 VDC
                           standard and high emperature. The standard heat detector is classified            Size inc base                                100Dia x 50H mm
                           as an A2S device and will report an alarm at 55°C. The high temperature          Operating temperature                        A2S: -20°C to +70°C (no icing)
                           detector, classified as a CS device, will report an alarm at 90°C.                                                             CS: -20°C to +120°C (no icing)
                                                                                                            Relative humidity                            0 to 95% (non condensing)
                           ❚ Ideal in environments that are dirty or smoky under normal conditions          IP rating                                    IP53
                           ❚ Well suited for warehouses, loading bays and car parks                         Weight inc base                              157 grams
                           ❚ Unaffected by wind or atmospheric pressure
                                                                                                             XP95 Heat Detector Standard – BR (Type A)                            201-0001
                           Approvals: AS1603.1                                                               XP95 Heat Detector Standard – AS (Type B)                            201-0001




                           XP95 Intelligent Detector Base

                           All detectors in the XP95 range fit the Intelligent Detector Base. It is a low
                           insertion force base with stainless steel contacts for the detector terminals.   Size                                         100Dia x 8H mm
                                                                                                            Operating temperature                        -20°C to +60°C (no icing)
                                                                                                            Relative humidity                            0 to 95% (non condensing)
                           ❚ XPERT addressing                                                               Weight                                       55 grams
                           ❚ One way fit of detector
                           ❚ Locking feature to prevent unauthorised removal                                 XP95 Intelligent Detector Base (White)                               201-0004
                                                                                                             XP95 Intelligent Detector Base (Black)                               201-0093
                           Approvals: AS1603:Pt1&2




AUS / PAGE 56       CONTACT AMPAC                                 HOME               CONTENTS               SEARCH              ZOOM            PRINT           EXIT
   DETECTORS    XP95 Intelligent



                           XP95 Isolating Base
                                                                                                          Voltage                                   17-28 VDC
                           The new style Isolating Base senses and detects short-circuit faults on        Quiescent current                         47μA (non isolating)
                           XP95 loops and spurs.                                                                                                    4mA (isolating)
                                                                                                          Size                                      100Dia x 24H mm
                           ❚ Up to 20 devices may be installed between isolating bases                    Operating temperature                     -20°C to +60°C (no icing)
                           ❚ High brightness LED                                                          Relative humidity                         0 to 95% (non condensing)
                                                                                                          Weight                                    100 grams

                                                                                                           XP95 Isolating Base                                            201-0125




                           Blank XPERT Card                                                               Pre-addressed XPERT Card

                           A universal address card supplied with all bases. Using a coding guide, pips   Pre-addressed XPERT cards are supplied with pips already removed.
                           are removed to set the address of the inserted detector.
                                                                                                          ❚ Saves time and increases accuracy during commissioning
                           ❚   Simplifies and speeds up installation and commissioning                     ❚ Pre-numbered 1-126
                           ❚   Uses patented, proven technology
                           ❚   Address remains the same, no matter how often detectors are replaced        Blank XPERT Card                                         38531-771-AMP
                           ❚   Flexibility to create any address                                           Pre-addressed XPERT Card 1-126                                 201-0013




AUS / PAGE 57       CONTACT AMPAC                                HOME               CONTENTS              SEARCH              ZOOM          PRINT          EXIT
   DETECTORS    XP95 Intelligent



                           Ampac Duct Sampling Unit

                           The Ampac Duct Sampling Unit is designed to monitor levels of smoke in       ❚ Easily accessible wire clamping terminals ensure secure and fast
                           air ducts operating in air speeds of 0.5 to 20 meters per second.              termination
                                                                                                        ❚ Clear cover hence the alarm LED on the detector is visible at all times
                           The duct smoke detector can be fitted to any wall of a ventilation duct       ❚ Unique self-sealing test port allows the dispensing of test smoke via a
                           and has two tubes that extend into the duct through punched holes.             needle into the duct smoke detector to be tested without the need to
                           The perforated sampling tube is placed in the airflow upstream of the           remove the cover
                           exhaust tube which causes a pressure differential in the duct detector. Air   ❚ Sampling pipes available in 4 lengths
                           is sucked up the sampling tube, across the detector and exhausted back       ❚ Weather resistant enclosure
                           into the air duct.
                                                                                                        Approvals: C-tick, AS1603-13


                                                                                                        Housing                                           Grey - ABS
                                                                                                        Cover                                             Transparent - ABS
                                                                                                        Dimension                                         115H x 340W x 60D mm
                                                                                                        Temperature Range                                 0 to +60°C
                                                                                                        Humidity                                          Up to 85%, no condensation
                                                                                                        Weight                                            5.5 kg

                                                                                                          Duct Sampling Unit fitted with Apollo XP95 Detector Base              214-0051
                                                                                                          Sampling Pipe 300 to 760mm                                           214-0060
                           Using the 360mm sampling pipe supplied, an air duct of up to 560mm             Sampling Pipe 760 to 1500mm                                          214-0061
                           can be monitored. For duct widths greater than 560mm, three other              Sampling Pipe 1500 to 3000mm                                         214-0062
                           lengths of sampling pipe are available:                                        XP95 Photo Optical Head                                              201-0003
                                                                                                          Discovery 0.5% Head                                                  201-0094
                           1. For duct width 300 to 760mm
                                                                                                        Note: The detector head is sold separately to the duct sampling unit
                           2. For duct width 760 to 1500mm
                           3. For duct width 1500 to 3000mm

                           ❚ Both sampling and exhaust pipes are fitted to the back box without
                             the need for tools making installation easier
                           ❚ The cover of the duct smoke detector is monitored to ensure working
                             integrity and if removed, causes a fault to appear at the fire alarm
                             control panel




AUS / PAGE 58       CONTACT AMPAC                                HOME              CONTENTS             SEARCH               ZOOM               PRINT              EXIT
    DETECTORS




Discovery
Intelligent Detectors
Discovery is a range of high-specification, intelligent fire detectors developed to meet
the requirements of sophisticated systems while providing engineers with an additional
dimension in fire protection capability. Discovery has a ‘distributed intelligence system’
where decisions are made in the detector head as well as at the control panel. Drift
compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty
environments reducing false alarms.


❚ Rejection of transient signals
❚ Flashing LED option
❚ Five response modes for ease of optimisation to changing environments
❚ Drift compensation to ensure constant sensitivity
❚ Four bytes of non-volatile memory for user data
❚ Alarm flag for fast alarm reporting
❚ Conventional alarm facility during control panel processor fault
❚ 360° visibility in alarm
❚ Compatible with XP95 systems
❚ Insect resistant




AUS / PAGE 59                      CONTACT AMPAC                                  HOME        CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   DETECTORS    APOLLO DISCOVERY Intelligent



                          Discovery Heat Detector

                          The Discovery Heat Detector, distinguishable by the low airflow resistant
                          case, uses a single thermistor to sense the air temperature around the       Voltage                                       17-28 VDC
                                                                                                       Quiescent current                             500μA at 24 VDC
                          detector.
                                                                                                       Alarm current                                 3.4mA at 24 VDC
                                                                                                       Size inc base                                 100Dia x 50H mm
                          ❚   Ideal in environments that are dirty or smokey under normal conditions   Operating temperature                         0°C to +80°C (no icing)
                          ❚   Well suited for warehouses, loading bays and car parks                   Relative humidity                             0 to 95% (non condensing)
                          ❚   Unaffected by wind or atmospheric pressure                                IP rating                                     IP53
                          ❚   Remote test feature                                                      Weight inc base                               160 grams

                          Approvals: AS1603.1                                                            Discovery Heat Detector (Type CR)                                 201-0089
                                                                                                         Discovery Heat Detector (Type CS)                                 201-0090




AUS / PAGE 60       CONTACT AMPAC                               HOME              CONTENTS             SEARCH            ZOOM                PRINT          EXIT
   DETECTORS    APOLLO DISCOVERY Intelligent



                          Discovery Multisensor Detector

                          The Discovery Multisensor Detector comprises optical smoke and
                          thermistor temperature sensors whose respective outputs can be split             Voltage                                     17-28 VDC
                                                                                                           Quiescent current                           500μA at 24 VDC
                          to deliver specific smoke or thermal actions respectively. This capability
                                                                                                           Alarm current                               3.5mA at 24 VDC
                          can aid early Alarm warning routines and other advanced detection                Size inc base                               100Dia x 58H mm
                          techniques.                                                                      Operating temperature                       -20°C to +60°C (no icing)
                                                                                                           Relative humidity                           0 to 95% (non condensing)
                          ❚   Ideal for a wide range of applications                                       IP rating                                   IP43
                          ❚   Highly immune to false alarms                                                Weight inc base                             160 grams
                          ❚   Well suited for environments such as hotel bedrooms
                          ❚   Unaffected by wind or atmospheric pressure                                      Discovery Multisensor Detector                                    201-0094
                          ❚   Well suited for sensitive environments
                          ❚   Heat only, optical only options
                          ❚   Remote test feature

                          Approvals: AS1603.1



                                                        Mode                Smoke Sensitivity         Temperature Sensitivity          Response Type              Minimum Time to
                                                                              (grey smoke)                  (relative)                                            Alarm (seconds)
                                Multisensor
                                                                         % per m        % per ft
                                 Detector                 1                1.1            0.35                 High                      Multisensor                      20
                                Operating                 2                2.1             0.7          No response to heat               Optical                         30
                                                          3                2.8             0.9                  Low                      Multisensor                      20
                                  Modes                   4                4.2             1.4                 High                      Multisensor                      20
                                                          5               No response to smoke                See text                    Heat A1                         30




AUS / PAGE 61       CONTACT AMPAC                                HOME              CONTENTS                SEARCH               ZOOM          PRINT           EXIT
   DETECTORS    APOLLO DISCOVERY Intelligent



                          Discovery Carbon Monoxide Detector

                          The Discovery Carbon Monoxide (CO) Detector is good at detecting deep-
                          seated fires. Please note that CO detectors do not detect smoke particles        Voltage                                     17-28 VDC
                                                                                                          Quiescent current                           500μA at 24 VDC
                          or heat and are not universal replacements for smoke detectors.
                                                                                                          Alarm current                               3.5mA at 24 VDC
                                                                                                          Size inc base                               100Dia x 50H mm
                          ❚   Enhanced detection capability                                               Operating temperature                       0°C to +50°C (no icing)
                          ❚   Early response to hot fires                                                  Relative humidity                           15 to 95% (non condensing)
                          ❚   Ideal for smouldering fires                                                  IP rating                                   IP43
                          ❚   Less susceptible to false alarms caused by steam than smoke alarms          Weight inc base                             160 grams
                          ❚   Five response modes                                                         Cell life (max)                             7 years

                          Approvals: AS1603.14                                                             Discovery Carbon Monoxide Detector                                  201-0102




                                                       Mode         Alarm Threshold         Minimum Time to Alarm            Typical Application
                                                                         (ppm)                    (seconds)

                                                         1                30                         60                      Sleeping with no ambient CO
                                  Relative
                                                         2                45                         30                      General use fast response such as supplementary
                              Performance of                                                                                 protection in atria
                               Detectors in              3                45                         60                      General use and sleeping risk with some low-level CO
                                                                                                                             (such as from light smoking or an unventilated gas fire)
                                 Test Fires
                                                         4                60                         30                      General smoking area and supplementary detection of
                                                                                                                             deep seated fires such as laundry rooms
                                                         5                75                         30                      Supplementary use in kitchen or boiler room




AUS / PAGE 62       CONTACT AMPAC                               HOME             CONTENTS                 SEARCH           ZOOM             PRINT             EXIT
   DETECTORS    APOLLO DISCOVERY Intelligent



                          Discovery Intelligent Detector Base

                          All detectors in the Discovery range fit the Intelligent Detector Base. It is
                          a low insertion force base with stainless steel contacts for the detector      Size                                            100Dia x 8H mm
                                                                                                         Operating temperature                           -20°C to +60°C (no icing)
                          terminals. XPERT cards are supplied with all bases.
                                                                                                         Relative humidity                               0 to 95% (non condensing)
                                                                                                         Weight                                          55 grams
                          ❚ XPERT addressing
                          ❚ One way fit                                                                     Discovery Intelligent Detector Base                                 201-0004
                          ❚ Locking feature to prevent unauthorised removal

                          Approvals: AS1603.1&2




                          Discovery Isolating Base

                          The new style Isolating Base senses and detects short-circuit faults on
                          loops and spurs.                                                               Voltage                                         17-28 VDC
                                                                                                         Quiescent current                               47μA (non isolating)
                                                                                                                                                         4mA (isolating)
                          ❚ Up to 20 devices may be installed between isolating bases                    Size                                            100Dia x 24H mm
                          ❚ High brightness LED                                                          Operating temperature                           -20°C to +60°C (no icing)
                                                                                                         Relative humidity                               0 to 95% (non condensing)
                                                                                                         Weight                                          100 grams

                                                                                                           Discovery Isolating Base                                            201-0125




AUS / PAGE 63       CONTACT AMPAC                                 HOME               CONTENTS            SEARCH              ZOOM                PRINT          EXIT
   DETECTORS    APOLLO DISCOVERY Intelligent



                          Blank XPERT Card                                                               Pre-addressed XPERT Card

                          A universal address card supplied with all bases. Using a coding guide, pips   Pre-addressed XPERT cards are supplied with PIPs already removed.
                          are removed to set the address of the inserted detector.
                                                                                                         ❚ Saves time and increases accuracy during commissioning
                          ❚   Simplifies and speeds up installation and commissioning                     ❚ Pre-numbered 1-126
                          ❚   Uses patented, proven technology
                          ❚   Address remains the same, no matter how often detectors are replaced        Blank XPERT Card                                        38531-771-AMP
                          ❚   Flexibility to create any address                                           Pre-addressed XPERT Card 1-126                                201-0013




AUS / PAGE 64       CONTACT AMPAC                               HOME              CONTENTS               SEARCH           ZOOM             PRINT         EXIT
   DETECTORS    BEAM DETECTORS Conventional



                         Beam Smoke – FIRERAY 2000

                         The FIRERAY 2000 is a conventional infrared optical beam smoke detector.
                         It is an End to End type beam detector and is thus less susceptible to stray   Operating range                       10-100 metres
                                                                                                        Operating voltage                     10.2VDC to 30VDC
                         reflections since any reflection goes back towards the transmitter. As a
                                                                                                        Fire relay contacts                   Norm open volt free 2A @ 30VDC
                         result projected Optical Beams can operate within narrower gaps than                                                 Resistive
                         reflective types.                                                               Fault relay contacts                  Norm closed volt free 2A @ 30VDC
                                                                                                                                              Resistive
                         ❚   Separate transmitter and receiver                                          Condition                             Alarm condition: fire relay closing
                         ❚   Range 10 to 100 metres                                                                                           May be latching or non-latching
                         ❚   Low current consumption                                                    Operating temperature                 -20°C to +55°C (no icing)
                         ❚   Automatic drift compemsation                                               Relative humidity                     0-90% (non condensing)
                         ❚   3 x selectable sensitivity threshold levels                                IP rating                             IP50
                         ❚   Low level control unit
                                                                                                         Beam Smoke – FIRERAY 2000                                    220-0004
                         ❚   Optional electronic alignment tool

                         Approvals: AS1603-7, EN54-12 and UL268




AUS / PAGE 65      CONTACT AMPAC                                  HOME            CONTENTS              SEARCH                 ZOOM   PRINT          EXIT
   DETECTORS    BEAM DETECTORS Conventional



                         Beam Smoke – FIRERAY 5000 Motorised Beam System

                         The FIRERAY 5000 Optical Beam Smoke Detectors can be used to provide
                         ‘wide area’ smoke detection. They are usually used in situations where           Operating distance (separation)                8-100 metres
                                                                                                          Cable length – system controller to detector
                         it is impractical, inappropriate or not cost effective (installation, wiring
                                                                                                          (2 core screened fire resistant)                100 metres
                         and maintenance) to use traditional point-type detectors. It also enables        Operating voltage (to system controller)       14VDC to 28VDC
                         coverage of a large area, at minimal cost. Optical beam smoke detectors          Operating temperature                          -10°C to +55°C (no icing)
                         are also ideally suited for situations that might include high ceilings, dusty   Relative humidity                              93% (non condensing)
                         and dirty environments, or environments that experience temperature              IP rating                                      IP54
                         extremes.
                                                                                                           FIRERAY 5000 Motorised Beam System
                         ❚   Up to 4 optical beam detectors per system controller                          System Controller, Detector and Reflector                                  220-0008
                         ❚   Easy fit system                                                                Additional Detector and Reflector                                          220-0009
                         ❚   Ground level control                                                          Single Reflector <50m                                                      220-0007
                                                                                                           3 x Reflector Long Range 100m Kit                                          220-0010
                         ❚   Laser assisted alignment
                                                                                                           Universal Bracket                                                         220-0011
                         ❚   Auto-optimise beam alignment                                                  1 Prism Plate                                                             220-0012
                         ❚   Contamination compensation                                                    4 Prism Plate                                                             220-0013
                         ❚   Building shift compensation                                                   Universal Ceiling Mount                                                   220-0014

                         Approvals: AS7240-12, EN54-12 and UL268




AUS / PAGE 66      CONTACT AMPAC                                 HOME               CONTENTS              SEARCH             ZOOM              PRINT            EXIT
   DETECTORS




Orbis
Marine Conventional Detectors
Orbis Marine conventional fire detectors offer a wealth of features to save time, enhance
reliability and reduce false alarms within the marine environment. These include drift
compensation and DirtAlert, a feature that warns service engineers via a flashing yellow
LED that detectors need maintenance; and patented FasTest, a procedure that takes just
four seconds to test smoke detectors and confirm that they are functioning correctly.



❚ Approved for use in marine environments
❚ Modern, low profile design
❚ TimeSaver Base for fast installation
❚ Transient rejection for false alarm reduction
❚ High humidity tolerance up to 98%RH
❚ Wide operating temperature -40˚C to +70˚C




AUS / PAGE 67                    CONTACT AMPAC                                 HOME       CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   DETECTORS    ORBIS Marine Conventional



                          Orbis Marine Optical Smoke Detector

                          The Orbis Marine Optical Smoke Detector works on the well established
                          light scatter principle. However, the sensing technology is radically      Operating voltage                            8.5 to 33 VDC
                                                                                                     Quiescent current                            65μA at 24 VDC
                          different in design from previous optical detectors and significantly
                                                                                                     Alarm current                                40mA at 24 VDC
                          reduces false alarms.                                                      Remote output                                1.2kΩ to -ve supply
                                                                                                     Size                                         97Dia x 31H mm
                          ❚   Responds well to slow-burning, smouldering fires                        Operating temperature                        -40°C to +70°C (no icing)
                          ❚   Performs well in black and white smoke                                 Relative humidity                            0 to 98% (non condensing)
                          ❚   Extra confirmation of smoke before alarm signal is given                IP rating                                    IP23D (EN60529)
                          ❚   Reduced incidents of false alarms                                      Weight                                       75 grams
                          ❚   Sensing chamber keeps out dust and other airborne contaminants
                          ❚   Operates over a broad range of voltages at extremes of temperature      Orbis Marine Optical Smoke Detector                           201-0501 MAR

                          Approvals: EN54-7/LPCB




                          Orbis Marine Multisensor Detector

                          The Orbis Marine Multisensor Detector benefits from the same false alarm
                          reduction technology as the optical detector. It is a thermally enhanced   Operating voltage                            8.5 to 33 VDC
                                                                                                     Quiescent current                            65μA at 24 VDC
                          smoke detector and so will not give an alarm from heat alone.
                                                                                                     Alarm current                                40mA at 24 VDC
                                                                                                     Remote output                                1.2kΩ to -ve supply
                          ❚   Responds well to fast-burning, flaming fires                             Size                                         97Dia x 42H mm
                          ❚   Reduced incidence of false alarms                                      Operating temperature                        -40°C to +70°C (no icing)
                          ❚   Increased reliability of detection                                     Relative humidity                            0 to 98% (non condensing)
                          ❚   Sensing chamber keeps out dust and other airborne contaminants         IP rating                                    IP23D (EN60529)
                          ❚   Operates over a broad range of voltages at extremes of temperature     Weight                                       80 grams

                          Approvals: EN54-7/LPCB                                                      Orbis Marine Multisensor Detector                         ORB-OH-43001-MAR




AUS / PAGE 68       CONTACT AMPAC                              HOME              CONTENTS            SEARCH            ZOOM               PRINT          EXIT
   DETECTORS    ORBIS Marine Conventional



                          Orbis Marine Heat Detector

                          The Orbis Marine Heat Detector uses a single thermistot to sense the air
                          temperature around the detector. There are five classes of heat detectors    Operating voltage                       8.5 to 33 VDC
                                                                                                      Quiescent current                       65μA at 24 VDC
                          in the Orbis Marine range designed to suit a wide variety of operating
                                                                                                      Alarm current                           40mA at 24 VDC
                          conditions.                                                                 Remote output                           1.2kΩ to -ve supply
                                                                                                      Size                                    97Dia x 36H mm
                          ❚   Can be used for applications where smoke detectors are unsuitable       Operating temperature                   -40°C to +70°C (no icing)
                          ❚   Ideal in environments that are dirty or smoky under normal conditions   Relative humidity                       0 to 98% (non condensing)
                          ❚   Reduced incidences of false alarms                                      IP rating                               IP23D (EN60529)
                          ❚   Increased reliability of detection                                      Weight                                  70 grams

                          Approvals: EN54-5/LPCB                                                       Orbis Heat Detector
                                                                                                       A1R Standard                                             201-0512 MAR
                                                                                                       BR Standard                                              201-0514 MAR
                                                                                                       BS Standard                                              201-0515 MAR
                                                                                                       CR Standard                                              201-0516 MAR
                                                                                                       CS Standard                                              201-0517 MAR




                          Orbis Marine TimeSaver Base

                          The Orbis Marine TimeSaver Base is a completely new design that provides
                          installers with an open working area with fixing holes shaped to allow a     Size                                    100Dia x 8H mm
                                                                                                      IP rating                               IP23D (EN60529)
                          simple mounting procedure.
                                                                                                      Weight                                  60 grams

                          ❚ Grouped terminals to make wiring easy
                                                                                                        Orbis Marine TimeSaver Base                             201-0528 MAR
                          ❚ Two fixing centres
                          ❚ LED alignment mark
                          ❚ Cable stripping guide
                          ❚ Continuity link for voltage testing of zone wiring prior to
                            commissioning
                          ❚ Detector locking mechanism

                          Approvals: EN54/LPCB



AUS / PAGE 69       CONTACT AMPAC                                HOME              CONTENTS           SEARCH            ZOOM          PRINT          EXIT
   DETECTORS




Orbis IS
Intrinsically Safe
Conventional Detectors
Orbis IS is a range of conventional detectors which have been developed from the standard
Orbis smoke and heat detectors. Orbis IS is a range with modem styling and is electronically
compatible with Apollo Series 60 intrinsically safe conventional detectors. Orbis IS is
a demonstration of Apollo’s commitment to the market for high quality conventional
detectors for use in small to medium size installations. In developing this range, Apollo has
put ease of installation and reliability in dally operation at the forefront of considerations.



❚ TimeSaver Base
❚ Patented FasTest enabling functional testing in four seconds
❚ DirtAlert indicates limit of drift compensation
❚ Tolerates extreme uperating conditions: -40˚C to +70˚C
❚ False alarm reduction
❚ Flashing LED option




AUS / PAGE 70                    CONTACT AMPAC                                     HOME           CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   DETECTORS    ORBIS IS Intrinsically Safe Conventional



                           Orbis IS Optical Smoke Detector

                           The Orbis IS Optical Smoke Detector works using the light scatter principle,
                           and is ideal for applications where slow burning or smouldering fires are              Operating voltage                           8.5 to 33 VDC
                                                                                                                 Quiescent current                           65μA at 24 VDC
                           likely.
                                                                                                                 Alarm current                               40mA at 24 VDC
                                                                                                                 Remote output                               1.2kΩ to -ve supply
                           ❚   Reduces false alarms                                                              Size                                        97Dia x 31H mm
                           ❚   Recommended for early warning of fire in most areas                                Operating temperature                       -40°C to +70°C (no icing)
                           ❚   Improved sensitivity to black smoke                                               Relative humidity                           0 to 98% (non condensing)
                           ❚   Compensation for slow changes in sensitivity                                      IP rating                                   IP23D (EN60529)
                           ❚   Algorithms for reliability of alarm                                               Weight                                      75 grams

                           Approvals: EN54-7/LPCB                                                                  Orbis IS Optical Smoke Detector     Apollo Item No.     ORB-OP-52027-APO
                                                                                                                                                       Ampac Item No.               201-0604




                           Orbis IS Multisensor Detector

                           The Orbis IS Multisensor Detector benefits from the same false alarm
                           reduction technology as the optical detector. It is a thermally enhanced              Operating voltage                           8.5 to 33 VDC
                                                                                                                 Quiescent current                           65μA at 24 VDC
                           smoke detector and so will not give an alarm from heat alone.
                                                                                                                 Alarm current                               40mA at 24 VDC
                                                                                                                 Remote output                               1.2kΩ to -ve supply
                           ❚   Reduces false alarms                                                              Size                                        97Dia x 42H mm
                           ❚   Sensitive to fast burning, flaming fires                                            Operating temperature                       -40°C to +70°C (no icing)
                           ❚   Improved sensitivity to black smoke                                               Relative humidity                           0 to 98% (non condensing)
                           ❚   Compensation for slow changes in sensitivity                                      IP rating                                   IP23D (EN60529)
                           ❚   Algorithms for reliability of alarm                                               Weight                                      80 grams

                           Approvals: EN54-7/LPCB                                                                  Orbis IS Multisensor Detector       Apollo Item No.     ORB-OH-53027-APO
                                                                                                                                                       Ampac Item No.               201-0605




                           Please check www.apollo-fire.co.uk on a regular basis for up-to-date approvals information.



AUS / PAGE 71       CONTACT AMPAC                                   HOME                CONTENTS                 SEARCH              ZOOM            PRINT          EXIT
   DETECTORS    ORBIS IS Intrinsically Safe Conventional



                           Orbis IS Heat Detector

                           The Orbis IS Heat Detector monitors temperature by using a single
                           thermistor network which provides a voltage output proportional to the                Operating voltage                             8.5 to 33 VDC
                                                                                                                 Quiescent current                             65μA at 24 VDC
                           external air temperature. There are seven classes of heat detectors in the
                                                                                                                 Alarm current                                 40mA at 24 VDC
                           Orbis IS range designed to suit a wide variety of operating conditions.               Remote output                                 1.2kΩ to -ve supply
                                                                                                                 Size                                          97Dia x 36H mm
                           ❚   Can be used for applications where smoke detectors are unsuitable                 Operating temperature                         -40°C to +70°C (no icing)
                           ❚   Ideal in environments that are dirty or smoky under normal conditions             Relative humidity                             0 to 98% (non condensing)
                           ❚   Reduced incidences of false alarms                                                IP rating                                     IP23D (EN60529)
                           ❚   Increased reliability of detection                                                Weight                                        70 grams

                           Approvals: EN54-5/LPCB                                                                  Orbis IS Heat Detector
                                                                                                                   A2S Standard 50°C MAT Static          Apollo Item No.     ORB-HT-51147-APO
                                                                                                                                                         Ampac Item No.               201-0601
                                                                                                                   BR Standard 65°C MAT Rate-of-Rise     Apollo Item No.     ORB-HT-51149-APO
                                                                                                                                                         Ampac Item No.               201-0600
                                                                                                                   BS Standard 65°C MAT Static           Apollo Item No.     ORB-HT-51151-APO
                                                                                                                                                         Ampac Item No.
                                                                                                                   CR Standard 80°C MAT Rate-of-Rise     Apollo Item No.     ORB-HT-51153-APO
                                                                                                                                                         Ampac Item No.               201-0602
                                                                                                                   CS Standard 80°C MAT Static           Apollo Item No.     ORB-HT-51155-APO
                                                                                                                                                         Ampac Item No.               201-0603
                           MAT     Maximum Application Temperature




                           Please check www.apollo-fire.co.uk on a regular basis for up-to-date approvals information.



AUS / PAGE 72       CONTACT AMPAC                                   HOME                CONTENTS                 SEARCH             ZOOM               PRINT          EXIT
   DETECTORS    ORBIS IS Intrinsically Safe Conventional



                           Orbis IS TimeSaver Base

                           The Orbis IS TimeSaver Base is a completely new design that provides
                           installers with an open working area with fixing holes shaped to allow a               Size                                 100Dia x 8H mm
                                                                                                                 IP rating                            IP23D (EN60529)
                           simple mounting procedure.
                                                                                                                 Weight                               60 grams

                           ❚   Grouped terminals to make wiring easy
                                                                                                                    Orbis IS TimeSaver Base      Apollo Item No.        ORB-50018-APO
                           ❚   Two fixing centres                                                                                                 Ampac Item No.               201-0606
                           ❚   LED alignment mark
                           ❚   Detector locking mechanism

                           Approvals: EN54/LPCB




                           Galvanic Barrier

                           The Galvanic Barrier is installed in the safe area and ensures system
                           integrity

                           ❚ Ideal for conventional hazardous areas
                           ❚ Enables compliance with the ATEX directive
                                                                                                                    Galvanic Barrier             Apollo Item No.            29600-378
                           Approvals: EN54-5/LPCB                                                                                                Ampac Item No.              333-0004




                           Please check www.apollo-fire.co.uk on a regular basis for up-to-date approvals information.



AUS / PAGE 73       CONTACT AMPAC                                   HOME                CONTENTS                 SEARCH                ZOOM   PRINT          EXIT
   DETECTORS    ORBIS IS Intrinsically Safe Conventional



                           DIN-Rail Interface Enclosures

                           DIN-Rail Interface Enclosures are available and can be used for housing
                           intrinsically safe (IS) barriers or DIN-Rail mounted interfaces. A multi-
                           purpose label that features a section for use with IS systems is supplied. For
                           non-IS systems, the part referring to IS can simply be removed.

                           ❚ Allows multiple interfaces to be housed together
                           ❚ IP67                                                                                  DIN-Rail Interface Enclosure – 4 units              29600-239




                           Please check www.apollo-fire.co.uk on a regular basis for up-to-date approvals information.



AUS / PAGE 74       CONTACT AMPAC                                   HOME                CONTENTS                 SEARCH              ZOOM               PRINT   EXIT
   DETECTORS




XP95 IS
Intrinsically Safe
Intelligent Detectors
XP95 Intrinsically Safe (IS) detectors are a development of the well established intelligent
XP95 range from Apollo. XP95 IS detectors feature all the benefits of the standard range,
but are developed specifically for use in hazardous areas. The addresses of XP95 IS detectors
are set by means of the patented XPERT card.




AUS / PAGE 75                   CONTACT AMPAC                                    HOME          CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   DETECTORS    XP95 Intrinsically Safe Intelligent



                            XP95 IS Ionisation Smoke Detector




                                                                                                                                     }                     {
                            The XP95 IS Ionisation Smoke Detector uses a low activity radioactive foil
                            to detect fires by irradiating the air in the smoke chambers and causing               Voltage                                       14-22 VDC
                                                                                                                  Quiescent current                             Current is dependant
                            a current flow. If smoke enters the chamber, the current flow is reduced
                                                                                                                  Alarm current                                 on the type of
                            leading to an alarm.                                                                  Remote o/p current                            safety barrier used
                                                                                                                  Size inc base                                 100Dia x 50H mm
                            ❚   Detects super heating and flaming combustibles                                     Operating temperature                         -20°C to +40°C
                            ❚   Dual chamber technology                                                           Humidity                                      0 to 95% relative humidity
                            ❚   Wind resistant smoke inlets                                                       IP rating                                     IP43
                            ❚   Transient voltage protection                                                      Weight inc base                               161 grams
                            ❚   Fine gauze insect protection
                            ❚   Lockable security fitting                                                            XP95 IS Ionisation Smoke Detector     Apollo Item No.              55000-540
                            ❚   Must be connected to a suitable safety barrier and protocol translator                                                    Ampac Item No.                201-0103

                            Approvals:




                            XP95 IS Optical Smoke Detector




                                                                                                                                     }                     {
                            The XP95 IS Optical Smoke Detector works using the light scatter principle
                            and is ideal for applications where slow-burning or smouldering fires are              Voltage                                       14-22 VDC
                                                                                                                  Quiescent current                             Current is dependant
                            likely.
                                                                                                                  Alarm current                                 on the type of
                                                                                                                  Remote o/p current                            safety barrier used
                            ❚   Detects a wide range of fires                                                      Size inc base                                 100Dia x 50H mm
                            ❚   Insensitive to wind                                                               Operating temperature                         -20°C to +40°C
                            ❚   Transient voltage protection                                                      Humidity                                      0 to 95% relative humidity
                            ❚   Fine gauze insect protection                                                      IP rating                                     IP43
                            ❚   Simple construction allows detection chamber to be cleaned                        Weight inc base                               157 grams
                            ❚   Lockable security fitting
                            ❚   Must be connected to a suitable safety barrier and protocol translator              XP95 IS Optical Smoke Detector        Apollo Item No.              55000-640
                                                                                                                                                          Ampac Item No.                201-0104
                            Approvals:

                            Please check www.apollo-fire.co.uk on a regular basis for up-to-date approvals information.



AUS / PAGE 76       CONTACT AMPAC                                    HOME                CONTENTS                 SEARCH             ZOOM               PRINT          EXIT
   DETECTORS    XP95 Intrinsically Safe Intelligent



                            XP95 IS Heat Detector




                                                                                                                                     }         {
                            The XP95 IS Heat Detector operates by measuring heat levels with a
                            single thermistor network which gives a count output proportional to the              Voltage                           14-22 VDC
                                                                                                                  Quiescent current                 Current is dependant
                            external air temperature.
                                                                                                                  Alarm current                     on the type of
                                                                                                                  Remote o/p current                safety barrier used
                            ❚   Rate of rise and fixed temperature alarm point                                     Size inc base                     100Dia x 50H mm
                            ❚   Single thermistor technology                                                      Operating temperature             -20°C to +40°C
                            ❚   Transient voltage protection                                                      Humidity                          0 to 95% relative humidity
                            ❚   Resettable operation                                                              IP rating                         IP53
                            ❚   Lockable security fitting                                                          Weight inc base                   157 grams
                            ❚   Must be connected to a suitable safety barrier and protocol translator
                                                                                                                    XP95 IS Heat Detector     Apollo Item No.              55000-440
                            Approvals: EN54-5/LPCB                                                                                            Ampac Item No.                201-0105




                            XP95 IS Mounting Base

                            The XP95 IS Mounting Base has been designed to accept only IS products.
                            This ensures that standard detectors cannot inadvertently be fitted into an            Size                              100Dia x 8H mm
                                                                                                                  Operating temperature             -20°C to +40°C
                            intrinsically safe system. XPERT cards are supplied with all bases.
                                                                                                                  Humidity                          0 to 95% relative humidity
                                                                                                                  Weight                            55 grams
                            ❚   Wide cable entry
                            ❚   Contains no electronic parts                                                        XP95 IS Mounting Base     Apollo Item No.              45681-215
                            ❚   One way only’ fit                                                                                              Ampac Item No.                201-0106
                            ❚   Low insertion force
                            ❚   Large terminations
                            ❚   Lockable security fitting
                            ❚   White finish
                            ❚   Must be connected to a suitable safety barrier and protocol translator

                            Approvals:


                            Please check www.apollo-fire.co.uk on a regular basis for up-to-date approvals information.



AUS / PAGE 77       CONTACT AMPAC                                    HOME                CONTENTS                 SEARCH             ZOOM   PRINT          EXIT
   DETECTORS    XP95 Intrinsically Safe Intelligent



                            XP95 IS Manual Call Point – Standard




                                                                                                                                       }                   {
                            The XP95 IS Manual Call Point is based on the standard waterproof model.
                            It features an ‘interrupt’ facility to provide fast response to an alarm.             Voltage                                       14-22 VDC
                                                                                                                  Quiescent current                             Current is dependant
                                                                                                                  Alarm current                                 on the type of
                            ❚   Waterproof                                                                                                                      safety barrier used
                            ❚   Red alarm LED                                                                     Size inc base                                 124H x 124W x 60D mm
                            ❚   Wide cable entry                                                                  Operating temperature                         0°C to +40°C
                            ❚   Large terminations                                                                Humidity                                      0 to 95% relative humidity
                            ❚   Manual Call Points must be connected to a suitable safety barrier and             IP rating                                     IP65
                                protocol translator                                                               Weight inc base                               400 grams

                            Approvals:                                                                              XP95 IS Manual Call Point – Standard
                                                                                                                    Without Flap – Red                     Apollo Item No.             55100-940
                                                                                                                                                           Ampac Item No.               201-0107




                            XP95 IS Protocol Translator and Galvanic Barrier

                            The Protocol Translator and Galvanic Barrier are installed in the safe area
                            ensuring integrity of communication between control equipment and                     Voltage                                       19-28 VDC
                                                                                                                  Size                                          110H x 20W x 92.5D mm
                            field devices and safety within the limits of BASEEFA approvals.
                                                                                                                  Operating temperature                         -20°C to +60°C
                                                                                                                  Humidity                                      0 to 95% relative humidity
                            ❚   Enables IS detectors to be connected to a standard loop driver                    Weight                                        100 grams
                            ❚   Loop powered
                            ❚   DIN-Rail mounting                                                                   XP95 IS Protocol Translator
                            ❚   Maximum of 20 XP95 IS devices per channel                                           Single Channel                         Apollo Item No.             55000-855
                            ❚   Translators must be connected to detectors via a suitable safety barrier                                                   Ampac Item No.               201-0108
                                                                                                                    Dual Channel                           Apollo Item No.             55000-856
                            Approvals:                                                                                                                     Ampac Item No.              55000-856
                                                                                                                    Galvanic Barrier                       Apollo Item No.             29600-098
                                                                                                                                                           Ampac Item No.              29600-098



                            Please check www.apollo-fire.co.uk on a regular basis for up-to-date approvals information.



AUS / PAGE 78       CONTACT AMPAC                                    HOME                CONTENTS                 SEARCH               ZOOM            PRINT           EXIT
   DETECTORS    XP95 Intrinsically Safe Intelligent



                            DIN-Rail Interface Enclosures

                            DIN-Rail Interface Enclosures are available and can be used for housing
                            intrinsically safe (IS) barriers or DIN-Rail mounted interfaces. A multi-
                            purpose label that features a section for use with IS systems is supplied. For
                            non-IS systems, the part referring to IS can simply be removed.

                            ❚ Allows multiple interfaces to be housed together
                            ❚ IP67

                                                                                                                    DIN-Rail Interface Enclosure – 4 units              29600-239




                            Please check www.apollo-fire.co.uk on a regular basis for up-to-date approvals information.



AUS / PAGE 79       CONTACT AMPAC                                    HOME                CONTENTS                 SEARCH              ZOOM               PRINT   EXIT
   DETECTORS




Flame Detectors
Specialist Intelligent Detectors
Flame detectors are effective inprotecting areas where flaming fires may be expected.
There is a choice of detection techniques - Ultra Violet and Infra-red, or a combination of
both. UV Flame Detectors are generally used in engine rooms, factories and warehouse
applications. Infra-red Flame Detectors are able to tolerate dirtier environments which
may block UV radiation and are generally used in applications such as waste handling,
colour printing and paper manufacturing.



❚ Detects a wide range of open fires
❚ Insensitive to wind
❚ Transient voltage protection
❚ Three types of detector
❚ Lockable security fitting
❚ White finish




AUS / PAGE 80                    CONTACT AMPAC                                     HOME       CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   DETECTORS    Flame Detectors



                          Intelligent Base Mounted UV Flame Detector

                          The Intelligent Base Mounted UV Flame Detector is designed to protect
                          internal areas where open fires may be expected. The detector has a single   Operating voltage
                                                                                                      Quiescent current
                          UV sensor with a narrow spectral response in order to discriminate
                                                                                                      Alarm current
                          between flames and most spurious sources of radiation.                       Remote output
                                                                                                      Size
                          ❚   Responds to stationary flames with no flicker                             Operating temperature
                          ❚   Sensitive to UV radiation emitted by flames during combustion            Relative humidity
                          ❚   Compact flame detector which can fit into Discovery or XP95 bases         IP rating
                          ❚   Loop-powered                                                            Weight
                          ❚   Increased reliability of detection
                                                                                                       Intelligent Base Mounted UV Flame Detector              55000-022
                          Approvals:                                                                   Base Mounted Flame Detector Bracket                     29600-458




                          Intelligent Base Mounted UV IR² Flame Detector

                          The Intelligent Base Mounted UV IR² Flame Detector is designed to protect
                          areas where open flaming fires may be expected. The detector has              Operating voltage
                                                                                                      Quiescent current
                          a UV and dual IR sensors responding to different wavelengths in order to
                                                                                                      Alarm current
                          discriminate between flames and spurious sources of radiation.               Remote output
                                                                                                      Size
                          ❚ Responds to stationary flames with no flicker                               Operating temperature
                          ❚ Sensitive to UV and low-frequency flickering IR radiation emitted by       Relative humidity
                            flames during combustion                                                   IP rating
                          ❚ Compact flame detector which can fit into Discovery or XP95 bases           Weight
                          ❚ Loop-powered
                          ❚ False alarms due to electrical discharges from lightning or arc welding    Intelligent Base Mounted UV IR² Flame Detector          55000-023
                            and flickering sunlight are minimised                                       Base Mounted Flame Detector Bracket                     29600-458

                          Approvals:




AUS / PAGE 81       CONTACT AMPAC                               HOME              CONTENTS            SEARCH            ZOOM             PRINT          EXIT
   DETECTORS    Flame Detectors



                          Intelligent Base Mounted IR³ Flame Detector

                          The Intelligent Base Mounted IR³ Flame Detector is designed to protect
                          areas where open flaming fires may be expected. The detector has three IR     Operating voltage
                                                                                                      Quiescent current
                          sensors that respond to different IR wavelengths in order to discriminate
                                                                                                      Alarm current
                          between flames and spurious sources of radiation.                            Remote output
                                                                                                      Size
                          ❚ Responds to stationary flames with no flicker                               Operating temperature
                          ❚ Sensitive to low-frequency flickering IR radiation emitted by flames        Relative humidity
                            during combustion                                                         IP rating
                          ❚ Compact flame detector which can fit into Discovery or XP95 bases           Weight
                          ❚ Loop-powered
                          ❚ False alarms due to factors such as flickering sunlight are avoided by a    Intelligent Base Mounted IR³ Flame Detector          55000-024
                            combination of filters and signal processing techniques                     Base Mounted Flame Detector Bracket                  29600-458

                          Approvals:




AUS / PAGE 82       CONTACT AMPAC                               HOME              CONTENTS            SEARCH            ZOOM             PRINT       EXIT
   DETECTORS    Flame Detectors



                          Intelligent Dual IR Flame Detector

                          The Intelligent Dual Infra-Red (IR²) Flame Detector is designed for use in
                          areas where flaming fires may be expected. The detector has two sensors         Operating voltage
                                                                                                        Quiescent current
                          which respond to different IR wavelengths to discriminate between flames
                                                                                                        Alarm current
                          and spurious sources of radiation. Applications include aircraft hangars,     Remote output
                          coal handling and paper manufacturing plants and woodworking                  Size
                          environments.                                                                 Operating temperature
                                                                                                        Relative humidity
                          ❚   Sensitive to flickering IR radiation                                       IP rating
                          ❚   Detects through films of oil, dust, water and ice                          Weight
                          ❚   Responds to flickering flames, including those invisible to the naked eye
                          ❚   Compatible with Discovery and XP95 protocols                               Intelligent IR² Flame Detector                     55000-280
                          ❚   Remote optical self-test function                                          Intelligent Flameproof IR² Flame Detector          55000-295
                          ❚   90° field of view
                          ❚   Up to 40m coverage

                          Approvals:




                          Intelligent Triple IR Flame Detector

                          The Intelligent Triple IR Flame Detector (IR³) is designed to protect areas
                          where open flaming fires may be expected. It is sensitive to lowfrequency,      Operating voltage
                                                                                                        Quiescent current
                          flickering infra-red radiation emitted by flames during combustion.
                                                                                                        Alarm current
                                                                                                        Remote output
                          ❚   Loop-powered                                                              Size
                          ❚   Sensitive to flickering IR radiation                                       Operating temperature
                          ❚   Detects through films of oil, dust, water and ice                          Relative humidity
                          ❚   Responds to flickering flames, including those invisible to the naked eye   IP rating
                          ❚   False alarms due to lighting or flickering sunlight are minimised          Weight
                          ❚   Compatible with Discovery and XP95 protocols
                                                                                                         Intelligent IR³ Flame Detector                     55000-020
                          Approvals:                                                                     Intelligent Flameproof IR³ Flame Detector          55000-021




AUS / PAGE 83       CONTACT AMPAC                               HOME               CONTENTS             SEARCH             ZOOM             PRINT    EXIT
   DETECTORS    Flame Detectors



                          Flame Detector Bracket

                          The Flame Detector Bracket is an optional accessory for the Intelligent
                          Flame Detectors. It is a stainless steel mounting bracket adjustable in two
                          axis. Not suitable for Base Mounted Flame Detectors.

                          ❚ Allows flame detector to be moved to desired position

                                                                                                         Flame Detector Bracket                                                     29600-203




                          Flame Detector Bracket

                          The Flame Detector Bracket is an optional accessory for the Intelligent
                          Flame Detectors. It is a stainless steel mounting bracket adjustable in two
                          axis.

                          ❚ Allows flame detector to be moved to desired position

                                                                                                         Flame Detector Bracket                                                     29600-458

                                                                                                        Note: this Item Code is for the bracket only. See page 84 for mounting box choices.




                          Flame Detector Weather Shield

                          The Flame Detector Weather Shield protects the device from inclement
                          conditions.

                          ❚ Protects against water ingress
                          ❚ Protects sensor from direct sunlight

                                                                                                         Flame Detector Weather Shield                                              29600-206




AUS / PAGE 84       CONTACT AMPAC                               HOME               CONTENTS             SEARCH               ZOOM               PRINT              EXIT
   DETECTORS    Flame Detectors



                          Deckhead Mounting Boxes

                          The Deckhead Mounting Box gives extra protection to devices to be fitted
                          in areas where there is the possibility of moisture or condensation
                          ingressing through the rear of the of the base. The new version is suitable
                          for a wider range of detector bases as well as Apollo’s AV bases.

                          ❚   Protects against water ingress
                          ❚   Improved performance                                                       NEW!! Deckhead Mounting Box                                  45681-217
                          ❚   Available in polycarbonate or metal                                        Metal Deckhead Mounting Box                                  29600-131
                          ❚   Polycarbonate Deckhead Mounting Box 45681-217 also fits Apollo              (has access ports threaded to fit PG16 glands)
                                                                                                         Metal Deckhead Mounting Box                                  29600-139
                              Audio Visual bases
                                                                                                         (has access ports threaded to fit M20 components)
                                                                                                         Deckhead Adaptor (for use with 29600-196 -
                                                                                                         converts cable glands from PG16 to M20)                      27249-005




                          Detector Base – Mounting Block

                          ❚ The mounting block is recommended for use when detectors are
                            installed on uneven surfaces                                                Size                                        100Dia x 28H mm
                                                                                                        Weight                                      35 grams
                          ❚ The mounting block ensures the correct fit with the base and the
                            detector, improves reliability and ensures that the mounting tags on the
                            base are not over tightened                                                  Detector Base – Mounting Block                                201-0101
                          ❚ Used with Base Mounted Flame Detector




AUS / PAGE 85       CONTACT AMPAC                               HOME              CONTENTS              SEARCH            ZOOM            PRINT             EXIT
   HIGH SENSITIVITY DETECTION SYSTEM




FastSense
High Sensitivity Detection System
FastSense is an aspirating system that adopts laser technology making it extremely
sensitive, thus providing the earliest warning to the slightest traces of smoke. FastSense
is available in 3 models: FastSense 25, FastSense 100, FastSense PLUS. The FastSense
25 accommodates sampling pipe up to 25 metres in length while the FastSense 100
and FastSense PLUS has total sampling pipe capacity of 100 metres and 200 metres
respectively.

All FastSense detectors incorporate the patented artificial intelligence software
ClassiFire. ClassiFire continually monitors the environment and internal contamination,
then adjusts the sensitivity of the detector for optimum performance. The
FastLearn feature is automatically initiatedon power up facilitating quick set-up on
commissioning.

FastSense detectors when networked can be programmed from a single nominated
point and when used in conjunction with an Apollo Protocol Interface Card, provides
control and indication at the Ampac FireFinder Fire Alarm Control Panel. Up to 126
detectors can be installed on a network data bus. A Remote Display Unit (RDU) provides
bar-graph and smoke density status indication of its associated detector. It is installed
on a FastSense network data bus.

A FastSense PLUS detector fitted with a command module will offer the single point
programming function of a networked system. FastSense 25 and FastSense100 are both
supplied with an easy to install docking station. The docking station is available with or
without the pipe exhaust port.

A range of sampling pipes and fittings complement the FastSense detector.




AUS / PAGE 86                   CONTACT AMPAC                                  HOME          CONTENTS   SEARCH   ZOOM   PRINT   EXIT
    HIGH SENSITIVITY DETECTION SYSTEM




FastSense
High Sensitivity Detection System
❚   Advanced Laser Technology
❚   ClassiFire Artificial Intelligence software
❚   Patented ‘Wastegate’ system
❚   In-built bar-graph and smoke level display; and programming
    (Available only with the FastSense PLUS)
❚   Apollo Protocol Interface Card Interface (APIC) provides portal for indication and
    control of FastSense detectors at Ampac’s FireFinder Fire Alarm Control Panel
❚   PC based remote software
❚   Remote Display Unit (RDU)
❚   SenseNet graphical display and control
❚   FastSense Matrix system
❚   PipeCalculator installation design software
❚   Extensive range of fittings




AUS / PAGE 87                    CONTACT AMPAC                                  HOME     CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   HIGH SENSITIVITY DETECTION SYSTEM FastSense



                                                                          FASTSENSE Models                               25           100            PLUS
                                                                          Voltage                                      27 VDC        27 VDC         27 VDC
                                                                          Quiescent current                            250mA         400mA          400mA

                                                                          Dimensions (mm)
                                                                          Height                                         215           220            372
                                                                          Width                                          140           300            427
                                                                          Depth                                           85           90             95

                                                                          Relay Outputs (All normally open 1 Amp)
                                                                          Fire 1                                       Optional      Optional        Fitted
                                                                          Fire 2                                       Optional      Optional        Fitted
                                                                          Pre-Alarm                                    Optional      Optional        Fitted
                                                                          Auxiliary                                    Optional      Optional        Fitted
                                                                          Fault                                        Optional      Optional        Fitted
                FastSense 25                   FastSense 100
                                                                          No. of Pipe Inlets                             1              2              4
                                                                          Max. Pipe Length                              25m           100m           200m
                                                                          Sensitivity Range
                                                                          Minimum                                        25%             25%          25%
                                                                          Maximum                                       0.03%           0.03%        0.03%
                                                                          Data Bus                                      1.2km           1.2km        1.2km
                                                                          IP Rating                                      IP50            IP50         IP50
                                                                          Operating temperature                                     -10°C to +60°C
                                                                          Humidity                                            0 to 90% non-condensing
                                                                          Weight                                        1.7kg            3.8kg        5.2kg

                                                                          Approvals                                                 AS1603.8



                                                                            FastSense 25 detector & docking station                                           230-0001
                                                                            FastSense 100 detector & docking station                                          230-0002
                                                                            FastSense PLUS detector                                                           230-0011
            FastSense PLUS                                                  FastSense PLUS detector + command module                                          230-0012




AUS / PAGE 88                  CONTACT AMPAC                   HOME   CONTENTS            SEARCH             ZOOM          PRINT             EXIT
   HIGH SENSITIVITY DETECTION SYSTEM FastSense



                         FastSense Apollo Protocol Interface Card

                         ❚   The Apollo Protocol Interface Card (APIC) provides the interface
                             between the FastSense detector and the Ampac FireFinder Fire Alarm       FastSense Apollo Protocol Interface Card                       230-0041
                             Control Panel (FACP)
                         ❚   Only one (1) APIC is required in a stand-alone or networked FastSense
                             configuration
                         ❚   Up to 126 networked FastSense detectors can be interfaced with the
                             FACP through the use of the APIC. The operator has control; and can
                             interrogate the status of each detector
                         ❚   Two (2) sets of 8-way DIP switches provide the facilities for correct
                             addressing
                         ❚   Power to the APIC is derived from the host FastSense detector via
                             interconnecting ribbon cable




                         FastSense Air Heater Box

                         ❚   The FastSense Air Heater Box should be used in applications where
                             the ambient temperature is below 0° centigrade                          Voltage                                     230 VAC
                                                                                                     Quiescent current                           1 Amp
                         ❚   The air heater box warms the sampled air before it arrives to the
                                                                                                     Dimension                                   265H x 138W x 160D mm
                             FastSense detector thus minimising the problems with surface            Weight                                      3.2 kg
                             condensation and ensuring components are operating within the
                             specified temperature tolerances                                          FastSense Air Heater Box                                       230-0042




AUS / PAGE 89      CONTACT AMPAC                               HOME              CONTENTS            SEARCH              ZOOM            PRINT         EXIT
   HIGH SENSITIVITY DETECTION SYSTEM FastSense



                         FastSense Wire Burn / Overload Unit

                         ❚   The Wire Burn / Overload Unit is used to provide a consistent method
                             of testing the FastSense detector                                      Voltage                                         230 VAC
                                                                                                    Quiescent current                               1 Amp
                         ❚   Special wire (230-0045) should be used inconjunction with the Wire
                                                                                                    Dimension                                       115H x 145W x 22D mm
                             Burn / Overload Unit to ensure consistent smoke source when testing    Weight 4 kg
                             the FastSense detector
                                                                                                     FastSense Wire Burn / Overload Unit                                   230-0044
                                                                                                     FastSense 100m Wire for Burn / Overload Unit                          230-0045




AUS / PAGE 90      CONTACT AMPAC                              HOME              CONTENTS            SEARCH              ZOOM           PRINT              EXIT
   HIGH SENSITIVITY DETECTION SYSTEM FastSense



                         SenseNet

                         SenseNET is a Windows based program that provides central management         The proprietary SenseNET operates on a dedicated communications bus.
                         and monitoring of up to 126 detectors.                                       Apart from the Control Unit and Command Module, other devices can also
                                                                                                      operate and communicate on this communications bus. These devices
                         The computer running the SenseNET program can communicate with a             include:
                         network of FastSense detectors, via a SenseNET control unit or Command
                         Module.                                                                      1. Contact Monitor – Ideal for alarm and fault status of third party
                                                                                                         products to be monitored. The Contact Monitor can accommodate
                         While the SenseNET control unit is an external desk-topstand-alone device       four (4 ) alarm, fault and two (2) additional inputs.
                         that provides the interface betweenthe computer and the network of           2. Remote Display Unit (RDU) – The bar graph (10 levels) and smoke
                         FastSense detectors, the Command Module is normally installed in a              levels (6 levels expressed as obscuration/ metre) of a FastSense
                         specific FastSense detector. This nominated FastSense detector will also be      detector can be remotely displayed using the RDU. Fire, Pre-Alarm,
                         featured with a larger LCD display to facilitate menu navigation.               Auxiliary and Fault status are also displayed.

                         The SenseNET graphics displays maps, produces warningsounds and
                         spoken instruction message which may beunique to each detector.
                                                                                                       SenseNET control unit c/w power supply                        230-0031
                         Detectors may be grouped togetherin zones, and represented by a zone
                                                                                                       SenseNET contact monitor                                      230-0032
                         map thus allowing alarms and faults to be quickly and easily located.         SenseNET software CD + dongle                                 230-0033
                                                                                                       SenseNET Remote Display Unit 19” board                        230-0034
                         SenseNET has the ability to scan all detectors on the communications          SenseNET Remote Display relay board                           230-0035
                         bus and read configuration settings. This feature is called SiteScanTM. To     SenseNET single RDU wall enclosure                            230-0036
                         facilitate installation and commissioning global changes may be executed
                         over the SenseNET communications bus.

                         Detector to detector communication uses standard RS485 protocol.
                         Maximum distance between detectors is 1.2 kilometres.




AUS / PAGE 91      CONTACT AMPAC                              HOME              CONTENTS              SEARCH           ZOOM             PRINT         EXIT
   HIGH SENSITIVITY DETECTION SYSTEM FastSense



                                                               Fittings

                                                               The FastSense TM detectors are complemented by a range of
                                                               light grey fittings intended to ensure that the system will suit
                                                               most applications. ‘The Clever Alternative’ extends beyond the
                                                               detectors and includes fittings with unique features. These
                                                               features include:

                                                               ❚   Pipes, printed with red markings, have ‘bell’ ends for easy fit to the next
                                                                   pipe, thus saving time and material (less need for coupling for pipe
                                                                   joins).
                                                               ❚   T-piece is available with friction or lock fitting.
                                                               ❚   The friction fit sampling points are aesthetically designed and have an
                                                                   easy fit ‘finger twist’ lock nut.
                                                               ❚   Resilient snap-on conduit saddle clips and collars, are a boon for
                                                                   installers.
                                                               ❚   Sampling kits are available with either friction or locking TPiece and
                                                                   also includes a one (1) metre sampling tube and sampling point.
                                                               ❚   Sampling pipe plug available for extending sampling point whilst
                                                                   being unobtrusive.




AUS / PAGE 92      CONTACT AMPAC             HOME   CONTENTS   SEARCH             ZOOM            PRINT            EXIT
   HIGH SENSITIVITY DETECTION SYSTEM FastSense



                                                               Fittings

                                                                FastSense Grey Fittings – 25mm
                                                                Pipe (4 metre length)                                      230-0061
                                                                Pipe coupling – standard                                   230-0062
                                                                Pipe coupling IP65 “Press Fit”                             230-0063
                                                                Small 90° bend – standard                                  230-0065
                                                                Small 90° bend IP65 “Press Fit”                            230-0066
                                                                Large 90° bend – standard                                  230-0067
                                                                End cap 25mm                                               230-0068
                                                                Sleeve adaptor 27– 25mm Grey FastSense25/100             ENC1457-A
                                                                Sleeve adaptor 27–25mm Black FastSense PLUS              ENC1458-A
                                                                Solvent Cement – 250mL                                     230-0088
                                                                Pipe clip - saddle type                                    230-0072
                                                                Pipe clip - collar type                                    230-0073
                                                                Pipe clip mounting rail (fits up to 4 pipes)                230-0074
                                                                Pipe clip - metal ring with 6mm thread                     230-0075
                                                                Pipe clip stand off support – M8 x 60mm stud                230-0087
                                                                Sampling Hole Pipe Labels – 200 per roll                   230-0121
                                                                Sampling Point Kits
                                                                Sampling Point Kit 10mm – friction fit                     230-0081
                                                                Sampling Point Kit 10mm – locking                         230-0082
                                                                Sampling Point Kit 8mm - friction fit                      230-0083
                                                                Sampling Point Kit 8mm - locking                          230-0084
                                                                Sampling Point Fittings
                                                                Sampling Point T Piece (friction fit) -10mm tube          ENC1468-A
                                                                Lock Fitting for ENC1468-A – 10mm tube                     230-0096
                                                                Sampling Point T Piece (friction fit) - 8mm tube          ENC1470-A
                                                                Lock Fitting for ENC1470-A – 8mm tube                      230-0095
                                                                Tube – 10mm (1metre length) natural                        230-0111
                                                                Tube – 10mm (100 metre roll) natural                       230-0112
                                                                Tube – 8mm (1metre length) natural                         230-0113
                                                                Tube – 8mm (100 metre roll) natural                        230-0114
                                                                Sampling Point Head (friction fit) - 10mm tube            ENC1466-A
                                                                Sampling Point Head (friction fit) - 8mm tube             ENC1467-A
                                                                Sampling Point Labels “Red”                                LAB1549
                                                                Sampling Point Bulkhead Fitting - 10mm tube                230-0099
                                                                Sampling Point Bulkhead Fitting - 8mm tube                 230-0100
                                                                Sampling Point Plug for Bulkhead Fitting                 ENC1451-A
                                                                Sampling Point Plug - 10mm tube                          ENC1452-A
                                                                Sampling Point Plug - 8mm tube                           ENC1453-A



AUS / PAGE 93      CONTACT AMPAC             HOME   CONTENTS   SEARCH            ZOOM             PRINT           EXIT
   INTERFACES




XP95/Discovery
Intelligent Interfaces
Apollo manufactures a comprehensive range of interfaces for intelligent systems which
enable fire protection systems to be engineered simply and effectively without the
need for custom-designed equipment. There are a variety of interfaces available to suit
a number of individual applications.

Standard Interfaces with Isolators are fitted with bi-directional short-circuit isolators
so that they are unaffected by a single short circuit on either loop input or output.
However, the Input/Output Unit and Output Unit with isolator are exceptions to this.
The removal of loop power to these interfaces will cause a ‘set’ relay to ‘reset’.

DIN-Rail Interfaces feature enclosures that clip to standard 35mm DIN-Rails or are
screwed to the base of a larger enclosure. They enable fire system designers to
determine the functions required and create multi-purpose interfaces for individual
sites.

Optimum protection can be provided when using the built-in isolator models.



❚ Easy to install
❚ Well protected
❚ Modular design
❚ A neat solution




AUS / PAGE 94                   CONTACT AMPAC                                   HOME       CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   INTERFACES   AMPAC INPUT/OUTPUT DEVICES Intelligent



                         Single Input Device (SID)

                         The Single Input Device is an addressable loop device for use on the
                         Apollo XP95 or Discovery protocol and provides a single monitored         Voltage                                          17-28 VDC
                                                                                                   Quiescent current                                1.82mA at 24 VDC
                         input.
                                                                                                   Max current                                      2.37mA at 24 VDC
                                                                                                   Monitored input                                  20k normal 500 - 15k closed
                         ❚   Interfaces a switch input to an Apollo addressable loop               Size – enclosure                                 132H x 82W x 55D mm
                         ❚   Loop powered                                                          Size – DIN chassis                               77H x 57W x 40D mm
                         ❚   One monitored input                                                   Operating temperature                            -20°C to +60°C (no icing)
                         ❚   Only one address used                                                 Humidity                                         0 to 95% relative humidity
                         ❚   Enclosure or DIN-Rail chassis mount                                   IP rating – enclosure                            IP55
                         ❚   Status indicators can be switched on and off                           Weight – enclosure                               155 grams
                                                                                                   Weight – DIN chassis                             75 grams

                                                                                                    Single Input Device (SID) – Boxed                                   201-0300
                                                                                                    Single Input Device (SID) – DIN mount                               201-0350




                         Single Input/Output Device (SIOD)

                         The Single Input/Output Device is an addressable loop device for use on
                         the Apollo XP95 or Discovery protocol and provides a single monitored     Voltage                                          17-28 VDC
                                                                                                   Quiescent current                                1.74mA at 24 VDC
                         input and a voltage free relay output.
                                                                                                   Max current                                      6.84mA at 24 VDC
                                                                                                   Relay contact rating                             1A at 24 VDC clean changeover
                         ❚   Interfaces a switch input and a relay output to addressable loop      Monitored input                                  20k normal 500 - 15k closed
                         ❚   Loop powered                                                          Size – enclosure                                 132H x 82W x 55D mm
                         ❚   One monitored input                                                   Size – DIN chassis                               77H x 57W x 40D mm
                         ❚   Single relay with clean changeover contact                            Operating temperature                            -20°C to +60°C (no icing)
                         ❚   Only one address used                                                 Humidity                                         0 to 95% relative humidity
                         ❚   Enclosure or DIN-Rail chassis mount                                   IP rating – enclosure                            IP55
                         ❚   Status indicators can be switched on and off                           Weight – enclosure                               155 grams
                                                                                                   Weight – DIN chassis                             75 grams

                                                                                                    Single Input/Output Device (SIOD) – Boxed                           201-0301
                                                                                                    Single Input/Output Device (SIOD) – DIN mount                       201-0351




AUS / PAGE 95      CONTACT AMPAC                               HOME              CONTENTS          SEARCH            ZOOM             PRINT            EXIT
   INTERFACES   AMPAC INPUT/OUTPUT DEVICES Intelligent



                         Three Input Device (3ID)

                         The Three Input Device is a versatile loop-powered three monitored input
                         unit device for use on the Apollo XP95 or Discovery protocol.              Voltage                                         17-28 VDC
                                                                                                    Quiescent current                               1.45mA at 24 VDC
                                                                                                    Max current                                     3.54mA at 24 VDC
                         ❚   Interfaces three switch inputs to addressable loop                     Monitored input                                 20k normal 500 - 15k closed
                         ❚   Loop powered                                                           Size – enclosure                                200H x 150W x 60D mm
                         ❚   Three monitored inputs                                                 Size – DIN chassis                              98H x 72W x 40D mm
                         ❚   Only one address used                                                  Operating temperature                           -20°C to +60°C (no icing)
                         ❚   Enclosure or DIN-Rail chassis mount                                    Humidity                                        0 to 95% relative humidity
                         ❚   Status indicators can be switched on and off                            IP rating – enclosure                           IP41
                                                                                                    Weight – enclosure                              500 grams
                                                                                                    Weight – DIN chassis                            125 grams

                                                                                                     Three Input Device (3ID) – Boxed                                   201-0308
                                                                                                     Three Input Device (3ID) – DIN mount                               201-0358




                         Three Input/Output Device (3IOD)

                         The Three Input/Output Device is a versatile loop-powered unit for use
                         on the Apollo XP95 or Discovery protocol. It provides three monitored      Voltage                                         17-28 VDC
                                                                                                    Quiescent current                               2.06mA at 24 VDC
                         inputs and three voltage free relay outputs.
                                                                                                    Max current                                     19.23mA at 24 VDC
                                                                                                    Relay contact rating                            1A at 24 VDC clean changeover
                         ❚   Interfaces three switch inputs and three relay outputs to              Monitored input                                 20k normal 500 - 15k closed
                             addressable loop                                                       Size – enclosure                                200H x 150W x 60D mm
                         ❚   Loop powered                                                           Size – DIN chassis                              98H x 72W x 40D mm
                         ❚   Three fault monitored input                                            Operating temperature                           -20°C to +60°C (no icing)
                         ❚   Three relays with clean changeover contact                             Humidity                                        0 to 95% relative humidity
                         ❚   Only one address used                                                  IP rating – enclosure                           IP41
                         ❚   Enclosure or DIN-Rail chassis mount                                    Weight – enclosure                              500 grams
                                                                                                    Weight – DIN chassis                            125 grams
                         ❚   Status indicators can be switched on and off
                                                                                                     Three Input/Output Device (3IOD) – Boxed                           201-0309
                                                                                                     Three Input/Output Device (3IOD) – DIN mount                       201-0359




AUS / PAGE 96      CONTACT AMPAC                               HOME               CONTENTS          SEARCH            ZOOM             PRINT           EXIT
   INTERFACES   AMPAC INPUT/OUTPUT DEVICES Intelligent



                         Three Input/Output Device (3IOD) EP – Externally Powered

                         The Three Input/Output Device EP is an externally powered unit device
                         for use on the Apollo XP95 or Discovery protocol. Using an external        Voltage                                        17-28 VDC
                                                                                                    Quiescent current – loop                       1.51mA at 24 VDC
                         24VDC power supply, each device draws a minimum amount of loop
                                                                                                    Quiescent current – external                   5.08mA at 24 VDC
                         current and provides three monitored inputs and three voltage free relay   Max current – loop                             7.20mA at 24 VDC
                         outputs.                                                                   Max current – external                         19.55mA at 24 VDC
                                                                                                    Relay contact rating                           1A at 24 VDC clean changeover
                         ❚   Interfaces three switch inputs and three relay outputs to              Monitored input                                20k normal 500 - 15k closed
                             addressable loop                                                       Size – enclosure                               200H x 150W x 60D mm
                         ❚   Externally powered                                                     Size – DIN chassis                             98H x 72W x 40D mm
                         ❚   Three fault monitored input                                            Operating temperature                          -20°C to +60°C (no icing)
                         ❚   Three relays with clean changeover contact                             Humidity                                       0 to 95% relative humidity
                                                                                                    IP rating – enclosure                          IP41
                         ❚   Only one address used
                                                                                                    Weight – enclosure                             500 grams
                         ❚   Enclosure or DIN-Rail chassis mount                                    Weight – DIN chassis                           125 grams
                         ❚   Status indicators can be switched on or off
                                                                                                     Three Input/Output Device (3IOD) EP – Boxed                      201-0310
                                                                                                     Three Input/Output Device (3IOD) EP – DIN mount                  201-0360




AUS / PAGE 97      CONTACT AMPAC                               HOME               CONTENTS          SEARCH             ZOOM           PRINT            EXIT
   INTERFACES   AMPAC INPUT/OUTPUT DEVICES Intelligent



                         Loop Powered Zone Interface Device (LZID)

                         AMPAC’s Loop Powered Zone Interface Device (LZID) is designed to
                         connect to the analogue loops in any of AMPAC’s addressable range of fire   Operating Voltage                              16Vdc – 27Vdc
                                                                                                    Zone Voltage (Loop Voltage ≥21V)               17 – 22Vdc
                         alarm control panels (FACP’s).
                                                                                                    End Of Line Values                             3K3Ω       6K2Ω       10uF
                                                                                                    Quiescent Current (EOL Fitted, Zone
                         ❚   Single Conventional Zone Input                                         oltage = 22V and no detector load              12mA         9mA    6mA
                         ❚   Apollo XP95 & Discovery protocol                                       Alarm Current (remote LED not fitted)           28.5mA       28.5mA 28.5mA
                         ❚   Supports up to 40 conventional detectors                               Alarm Current (remote LED fitted)               32mA         32mA   32mA
                         ❚   Remote LED Output                                                      No LZID’s / Loop                               12 x 250mA Loop
                         ❚   Short Circuit Isolation                                                                                               24 x 500mA Loop
                         ❚   Programmable EOL (3K3Ω, 6K2Ω or 10uF)                                  No. Detectors / Zone                           40 Max
                                                                                                    Operating temperature                          0°C to +70°C
                                                                                                    Dimensions
                                                                                                    DIN Mount                                      98 (L) x 72.5 (W) x 40mm (D)
                                                                                                    Enclosed / Boxed                               200 (L) x 150 (W) x 60mm (D)
                                                                                                    Weight
                                                                                                    DIN Mount                                      140g
                                                                                                    Enclosed / Boxed                               460g

                                                                                                     Loop Powered ZID (DIN Mount)                                        4210-0004
                                                                                                     Loop Powered ZID (Enclosed)                                         4210-0005




AUS / PAGE 98      CONTACT AMPAC                              HOME             CONTENTS             SEARCH             ZOOM                PRINT          EXIT
   INTERFACES   XP95/DISCOVERY Intelligent



                          Input/Output Unit with Isolator

                          The Input/Output unit with Isolator provides a voltage free, single, pole,
                          change-over relay output, a single, monitored switch input and an            Voltage                                      17-28vdc
                                                                                                       Quiescent current                            1.2mA at 24vdc
                          unmonitored, non-polarised opto-coupled input.
                                                                                                       Max current                                  3.5mA at 24vdc
                                                                                                       Relay contact                                1A at 30vdc
                          ❚   It can report fault, switch open and switch closed levels                Opto input                                   35vdc max
                          ❚   Three visible LEDs                                                       Monitored input voltage                      9-11vdc
                          ❚   Loop powered                                                             Operating temperature                        -20°C to +70°C (no icing)
                          ❚   Voltage free                                                             Relative humidity                            0 to 95% (non condensing)
                          ❚   Capable of switching up to 1A at 30V                                     IP Rating                                    IP54
                          ❚   Built-in short circuit isolator (fitted on 55000-847)                     Size                                         150W x 90H x 48D mm
                                                                                                       Weight                                       240 grams
                          Approvals: AS4428.1
                                                                                                        Input/Output Unit with Isolator                             55000-847-AMP
                                                                                                        Input/Output Unit (no Isolator)                                   201-0007




                          Zone Monitor with Isolator

                          The Zone Monitor with Isolator powers and controls the operation of a
                          zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery    Voltage                                      17-28vdc
                                                                                                       Quiescent current                            4mA + detector load
                          or XP95 Loop.
                                                                                                       Alarm current                                11mA at 24vdc
                                                                                                       EOL resistor value                           5.1k ¹⁄₃ watt
                          ❚ Loop powered                                                               Maximum capacitor on zone terminals          50µF
                          ❚ Visible LED                                                                Zone voltage                                 19V ± 1V
                          ❚ Built-in short circuit isolator (fitted on 55000-845)                       Operating temperature                        -20°C to +70°C (no icing)
                                                                                                       Relative humidity                            0 to 95% (non condensing)
                          Approvals: AS4428.1                                                          IP Rating                                    IP54
                                                                                                       Size                                         150W x 90H x 48D mm
                                                                                                       Weight                                       230 grams

                                                                                                        Discovery/XP95 Zone Monitor with Isolator                         201-0126
                                                                                                        Discovery/XP95 Zone Monitor (no Isolator)                         201-0012




AUS / PAGE 99      CONTACT AMPAC                                  HOME              CONTENTS           SEARCH             ZOOM            PRINT            EXIT
   INTERFACES    XP95/DISCOVERY Intelligent



                           Sounder Control Unit with Isolator

                           The XP95 Sounder Control Unit with Isolator is used to control the
                           operation of a zone of conventional sounders and report their status to    Voltage                                       17-28vdc
                                                                                                      Quiescent current                             1.95mA at 24vdc
                           the control panel.
                                                                                                      Loop current max                              4.5mA
                                                                                                      External supply                               9-32vdc 1.25A
                           ❚ Allows sounders to be operated continuously or be pulsed or be           External quiescent current                    3mA at 32vdc
                             pulsed, 1 second on 1 second off                                          External current max                          47mA + load
                           ❚ May be synchronized when in pulsed operation                             Sounder circuit load max                      1A at 30vdc
                                                                                                      Operating temperature                         -20°C to +70°C (no icing)
                           Approvals: AS4428.1                                                        Relative humidity                             0 to 95% (non condensing)
                                                                                                      IP Rating                                     IP54
                                                                                                      Size                                          150W x 90H x 48D mm
                                                                                                      Weight                                        240 grams

                                                                                                       Sounder Control Unit with Isolator                           55000-852-AMP
                                                                                                       Sounder Control Unit (no Isolator)                                 201-0010




                           Three Channel Input/Output Unit with Isolator

                           The Three Channel Input/Output unit with Isolator provides three voltage
                           free, single pole, change-over relay outputs, and three monitored switch   Voltage                                       17-28vdc
                                                                                                      Quiescent current                             3mA at 24vdc
                           inputs.
                                                                                                      Max current                                   7.5mA at 24vdc
                                                                                                      Relay contact                                 1A at 30vdc
                           ❚ Supervises one or more normally-open switches on each of                 Monitored input voltage                       9-11vdc
                             the three inputs                                                         Operating temperature                         -20°C to +70°C (no icing)
                           ❚ Loop powered                                                             Relative humidity                             0 to 95% (non condensing)
                           ❚ Capable of switching up to 30V at 1A on each of the three outputs        IP Rating                                     IP54
                           ❚ Built-in short circuit isolator                                          Size                                          250W x 175H x 75D mm
                                                                                                      Weight                                        621 grams
                           Approvals: AS4428.1
                                                                                                       Three Channel Input/Output Unit with Isolator                55000-588-AMP
                                                                                                       Three Channel Input/Output Unit (no Isolator)                      201-0115




AUS / PAGE 100      CONTACT AMPAC                               HOME               CONTENTS           SEARCH             ZOOM               PRINT          EXIT
   AUDIO VISUAL SIGNALLING




Audio Visual
Signalling
Ampac offers a wide range of Intelligent Audio Visual (AV) signalling devices for use in
conjunction with its range of intelligent and conventional detectors and control panels.
A versatile and functional range offering a huge choice for any application.

❚ Sounder Bases combine an alarm sounder and detector base

❚ Beacon Bases combine an alarm beacon and detector base

❚ Sounder Beacon Bases combine an alarm sounder, beacon and detector base

❚ Sounders are used to provide an audible indication of an alarm

❚ Beacons are used to provide an visual flashing indication of an alarm

❚ Sounder/Beacons are used to provide an audible and flashing indication of an alarm




AUS / PAGE 101                 CONTACT AMPAC                                  HOME         CONTENTS   SEARCH   ZOOM   PRINT   EXIT
   AUDIO VISUAL SIGNALLING       XP95/DISCOVERY INTELLIGENT SOUNDER BASES



                        Integrated Sounder Base

                        The Integrated Sounder Base comprises a base sounder with integral
                        mounting base and is for use with Discovery or XP95 ranges. It is    Voltage (polarity sensitive)             17-28 VDC
                                                                                             Quiescent current                        1.2mA
                        designed for indoor use.
                                                                                             Max current (sounder operated)           5mA
                                                                                             Max sounder output                       92dB(A)
                        ❚   Two volume ranges – via DIP switch setting                       Operating temperature                    -20°C to +60°C (no icing)
                        ❚   Synchronisation of ‘alert’ and ‘evacuate’ tones                  Relative humidity                        0 to 95% (non condensing)
                        ❚   Individual and group addressing                                  IP rating                                IP21D
                        ❚   Unique acoustic self-test                                        Size                                     115Dia x 38H mm
                        ❚   Integrated base                                                  Weight                                   140 grams
                        ❚   Isolator option is available
                                                                                              Integrated Base Sounder                                       201-0110
                        Approvals: AS1670.4                                                   White Cap                                                     201-0114




AUS / PAGE 102    CONTACT AMPAC                                  HOME         CONTENTS       SEARCH            ZOOM           PRINT          EXIT
   AUDIO VISUAL SIGNALLING       XP95/DISCOVERY INTELLIGENT SOUNDER BEACON BASES



                        Sounder Beacon Base

                        The Sounder Beacon Base is a loop-powered sounder and beacon
                        combined with a standard Intelligent Mounting Base. It is used to signal a   Voltage (polarity sensitive)             17-28 VDC
                                                                                                     Quiescent current                        300µA
                        fire alarm in enclosed areas. The Sounder Beacon Base can be used either
                                                                                                     Max current (sounder operated)           8mA
                        with a detector fitted or with a cap for operation as a stand-alone alarm     Max sounder output                       91dB(A)
                        device.                                                                      Operating temperature                    -20°C to +60°C (no icing)
                                                                                                     Relative humidity                        0 to 95% (non condensing)
                        ❚   Two volume ranges via DIP switch                                         IP rating                                IP21D
                        ❚   Beacon flash rate as per AS1670.4                                         Size                                     115Dia x 38H mm
                        ❚   Synchronisation of ‘alert’ and ‘evacuate’ tones                          Weight                                   160 grams
                        ❚   Synchronisation of beacon flash
                        ❚   Individual and group addressing                                           Sounder Beacon Base                                           201-0116
                        ❚   Unique acoustic and beacon self test                                      White Cap                                                     201-0114
                        ❚   Enables DDA compliance

                        Approvals: AS1670.4




AUS / PAGE 103    CONTACT AMPAC                                  HOME           CONTENTS             SEARCH            ZOOM           PRINT          EXIT
   AUDIO VISUAL SIGNALLING      XP95/DISCOVERY INTELLIGENT SOUNDERS


                        NEW
                        Intelligent Open-Area Sounder (Sonos)

                        The Intelligent Open-Area Sounder has been designed for use in open
                        areas and can be connected to any Discovery or XP95 system.           Voltage (polarity sensitive)                   17-28 VDC
                                                                                              Quiescent current                              333µA
                                                                                              Max current (sounder operated)                 5mA
                        ❚   Self-test fault monitoring                                        Max sounder output                             88-96dB(A) ±3dB(A)
                        ❚   Choice of tones                                                   Operating temperature                          -10°C to +55°C (no icing)
                        ❚   Group addressing and synchronisation of alarm                     Relative humidity                              0 to 95% (non condensing)
                        ❚   Weatherproof IP65                                                 IP rating                                      IP65
                        ❚   Comes with Isolating Base as standard                             Size                                           104Dia x 95.5H mm
                        ❚   Loop powered                                                      Weight                                         225 grams

                        Approvals: LPCB EN54-3/LPCB                                            Intelligent Open Area Sounder (Red) Sonos                           205-0100
                                                                                               Intelligent Open Area Sounder (White) Sonos                         205-0101




AUS / PAGE 104    CONTACT AMPAC                              HOME            CONTENTS         SEARCH            ZOOM             PRINT              EXIT
   AUDIO VISUAL SIGNALLING      XP95/DISCOVERY INTELLIGENT BEACONS



                        Loop-Powered Beacon

                        The Loop-Powered Beacon is a local-area beacon designed for indoor use.
                        The beacon has been developed as a supplement to sounders for use in            Voltage (polarity sensitive)                   17-28 VDC
                                                                                                        Quiescent current                              150µA
                        situations where there is a risk that sounders will not be heard.
                                                                                                        Max current (beacon operated)                  3mA
                                                                                                        Flash rate                                     1Hz
                        ❚   High intensity LED – more reliable than xenon beacons                       Operating temperature                          -20°C to +60°C (no icing)
                        ❚   Automatic LED check                                                         Relative humidity                              0 to 95% (non condensing)
                        ❚   Lockable                                                                    IP rating                                      IP23D
                        ❚   Wide angle of visibility                                                    Size                                           115Dia x 38H mm
                        ❚   Enables DDA compliance                                                      Weight                                         140 grams
                        ❚   Synchronised flash
                        ❚   Can be used with Discovery or XP95                                            Loop-Powered Beacon (Red)                                         201-0118
                                                                                                          Loop-Powered Beacon (Clear Lens/Red Flash) Standard Flash        55000-878
                        Approvals: AS1670.4                                                               Loop-Powered Beacon (Amber) Standard Flash                       55000-879




                        NEW
                        Intelligent Open-Area Beacon (Sonos)

                        The Intelligent Open-Area Beacon has been developed for use in situations
                        where there is a risk that sounders will not be heard. It is weatherproof and   Voltage (polarity sensitive)                   17-28 VDC
                                                                                                        Quiescent current                              333µA
                        can be used outside.
                                                                                                        Max current (beacon operated)                  3.1mA
                                                                                                        Flash rate                                     1Hz
                        ❚   Self-test fault monitoring                                                  Operating temperature                          -10°C to +55°C (no icing)
                        ❚   Weatherproof IP65                                                           Relative humidity                              0 to 95% (non condensing)
                        ❚   Group addressing                                                            IP rating                                      IP65
                        ❚   Synchronisation of alarm                                                    Size                                           104Dia x 97.5H mm
                        ❚   Comes with Isolating Base as standard                                       Weight                                         205 grams
                        ❚   Loop powered
                                                                                                          Intelligent Open Area Beacon (Red) Sonos                           208-0100
                        Approvals: AS1670.4                                                               Intelligent Open Area Beacon (Clear) Sonos                         208-0101




AUS / PAGE 105    CONTACT AMPAC                                HOME              CONTENTS               SEARCH             ZOOM             PRINT             EXIT
   AUDIO VISUAL SIGNALLING      XP95/DISCOVERY INTELLIGENT SOUNDER/BEACONS


                        NEW
                        Intelligent Open-Area Sounder Beacon

                        The Intelligent Open-Area Sounder Beacon has been designed for use in
                        open areas and can be connected to any Discovery or XP95 system.        Voltage (polarity sensitive)                 17-28 VDC
                                                                                                Quiescent current                            333µA
                                                                                                Max current (sounder/beacon operated)        8mA
                        ❚   Gives two functions at one point                                    Max sounder output                           100dB(A)
                        ❚   Self-test fault monitoring                                          Flash rate                                   1Hz
                        ❚   Choice of tones                                                     Operating temperature                        -10°C to +55°C (no icing)
                        ❚   Group addressing and synchronisation of alarm                       Relative humidity                            0 to 95% (non condensing)
                        ❚   Comes with Isolating Base as standard                               IP rating                                    IP65
                        ❚   Loop powered                                                        Size                                         104Dia x 97.5H mm
                                                                                                Weight                                       260 grams
                        Approvals: AS1670.4
                                                                                                 Intelligent Open Area Sounder Beacon (Red) Sonos                  205-0102
                                                                                                 Intelligent Open Area Sounder Beacon (Clear) Sonos                205-0103




AUS / PAGE 106    CONTACT AMPAC                              HOME            CONTENTS           SEARCH            ZOOM             PRINT              EXIT
   AUDIO VISUAL SIGNALLING      AMPAC STROBES



                        ASL-86 Strobe

                        ❚   Red or Amber Lens
                        ❚   High intensity output                                      Voltage                                      24 VDC
                                                                                       Current                                      140mA
                        ❚   ABS / Polycarbonate / Acrylic construction
                                                                                       Rating                                       10 Watts
                        ❚   Combined Red & Amber surface mount unit available          Size inc base                                100Dia x 88H mm
                                                                                       Flash rate                                   75 per minute
                                                                                       Operating temperature                        -20°C to + 60°C
                                                                                       IP rating                                    IP65
                                                                                       Weight – strobe                              182 grams
                                                                                       Weight – combined unit                       719 grams

                                                                                        ASL-86 Strobe (Red)                                           208-0007
                                                                                        ASL-86 Strobe (Amber)                                         208-0008
                                                                                        ASL-86 Strobe (Red & Amber) Combined Unit                     208-0011




AUS / PAGE 107    CONTACT AMPAC                             HOME            CONTENTS   SEARCH           ZOOM            PRINT             EXIT
   AUDIO VISUAL SIGNALLING      AMPAC STROBES (Conventional)



                        Sonos Low Current Visual Warning Device

                        The SONOS Low Current Visual Warning strobes are general purpose LED
                        strobes for fire, security and industrial applications. The strobes come with    Operating voltage                           17 – 60 VDC
                                                                                                        Current drain                               5mA
                        the flexibility of individual Red, Amber and Clear strobes or combined
                                                                                                        Operating Temperature                       -25°C to +70°C
                        Red/Amber strobe units complete with either a flush or surface mounting          IP Rating Shallow                           IP21
                        plate. The strobes utilises a full faced, translucent case which provides a     IP Rating Deep                              IP65
                        much larger lens area and a greater spread of light. The strobes are suitable   Colour Base                                 White
                        for use with AMPAC’s EV3000 system (both single and combined) and               Colour Lens                                 Red, Amber, Clear
                        AMPAC’s fire panels (Single only). Simple ‘twist and click’ insertion avoids     Approvals                                   C-tick
                        wiring andconnection problems.
                                                                                                         Sonos Low Current Visual Warning Device (Red)                  208-0060
                        ❚   Low current consumption                                                      Sonos Low Current Visual Warning Device (Amber)                208-0061
                        ❚   Simple ‘twist and click’ insertion                                           Sonos Low Current Visual Warning Device (Clear)                208-0062
                                                                                                         Sonos Low Current Visual Warning Device (Deep Base Only)       208-0064
                        ❚   Red, Amber and Clear options
                        ❚   Quick connect/disconnect
                        ❚   IP65 weather proof options (deep base units) for indoor
                            and outdoor use




                        Combined Strobe for EV3000

                        Due to its low current draw the Sonos strokes can be connected in larger         Combined Strobe for EV3000                                     208-0063
                        volumes onto the EV3000 visual output circuits.




AUS / PAGE 108    CONTACT AMPAC                                HOME              CONTENTS               SEARCH            ZOOM            PRINT            EXIT
   AUDIO VISUAL SIGNALLING     AMPAC STROBES (Conventional)



                        Combined Strobe for EV3000 (Surface Mount)

                        Item pictured is 208-0066 Indoor. The IP65 model uses the deep base to       Combined Strobe for EV3000 (Indoor)                                208-0066
                        achieve an outdoor solution where required.                                  Combined Strobe for EV3000 (IP65 Outdoor)                          208-0065




                        Strobe Sign Plate

                        Mounts directly behind the Single Red Sonos Strobe. Used outside the
                        main building entrance which leads fire fighters to the fire indicator panel   Fixing                                       Directly behind the Sonos Model
                                                                                                                                                 Strobe / Beacons
                        location. Outdoor strobes should always use the deep base.
                                                                                                    Material                                     Painted metal 1mm
                                                                                                    Size                                         120mm W X 160mm H

                                                                                                     Strobe Sign Plate                                                  207-0042




AUS / PAGE 109    CONTACT AMPAC                              HOME              CONTENTS             SEARCH               ZOOM         PRINT             EXIT
   AUDIO VISUAL SIGNALLING      AMPAC BELLS



                        Fire Alarm Bell 150mm

                        ❚   Motorised mechanism
                        ❚   Low current consumption                                          Voltage                                    24 VDC
                                                                                             Operating current                          25mA
                        ❚   Red finish with FIRE lettering
                                                                                             Size (without back box)                    150Dia x 56D mm
                        ❚   Suitable for indoor use                                          Sound Level                                92 dB @ 3m
                        ❚   Back box available – 206-0006                                    Operating temperature                      -10°C to +55°C (no icing)
                                                                                             Weight                                     764 grams

                                                                                              Bell 150mm                                                     206-0012



                        Fire Alarm Bell 200mm

                        ❚   Red finish with FIRE lettering
                        ❚   Solenoid actuating mechanism                                     Voltage                                    19-27 VDC
                                                                                             Operating current                          100mA
                        ❚   Suitable for indoor use
                                                                                             Size (without back box)                    200Dia x 70D mm
                        ❚   Back box available – 206-0006                                    Sound Level                                85 dB @ 3m
                                                                                             Operating temperature                      -20°C to +70°C (no icing)
                                                                                             Weight                                     1.25kg

                                                                                              Bell 200mm 24Vdc                                               206-0001



                        Bell Back Box

                        ❚   Allows surface mounting of bell
                        ❚   Screw thread conduit entry and protection for wiring terminals   Material                                   Aluminium cast
                                                                                             Finish                                     Red
                        ❚   Red finish
                                                                                             Depth                                      40 mm
                        ❚   Weather seal                                                     Weight                                     270 grams

                                                                                              Bell Back Box for 206-0012 and 206-0001                        206-0006




AUS / PAGE 110    CONTACT AMPAC                              HOME              CONTENTS      SEARCH             ZOOM            PRINT      EXIT
   AUDIO VISUAL SIGNALLING      AMPAC KEY HOLDERS



                        Key Holder – D2

                        ❚   Provides a visible place to locate a key used for emergency access
                        ❚   Red finish                                                            Size                               100Dia x 32D mm
                                                                                                 Finish                             Red
                        ❚   Instructions on glass
                                                                                                 Weight                             130 grams
                        ❚   Break glass operation similar to a manual call point
                        ❚   Suitable for indoor use
                                                                                                  Key Holder – D2                                     215-0003
                                                                                                  Spare Glass – D2                                    215-0004




AUS / PAGE 111    CONTACT AMPAC                               HOME              CONTENTS         SEARCH              ZOOM   PRINT      EXIT
   AUDIO VISUAL SIGNALLING      AMPAC REMOTE INDICATORS



                        Fire Alarm Remote Indicator – Round

                        ❚   Detector activation indicator
                        ❚   5mm Red LED                                         Voltage                                         24 VDC
                                                                                Current at 24v                                  1.5mA
                        ❚   Compact size
                                                                                Size                                            74Dia x 16H mm
                        ❚   Modern styling                                      Weight                                          26 grams
                        ❚   For conventional or analogue detectors
                        ❚   Choice of legend                                     Remote Indicator – Blank                                        209-0001
                                                                                 Remote Indicator – Fire Alarm in Concealed Space                209-0004
                                                                                 Remote Indicator – Fire Alarm in Roof Space                     209-0005
                                                                                 Remote Indicator – Fire Alarm in Room                           209-0006
                                                                                 Remote Indicator – Fire Alarm in Duct                           209-0007
                                                                                 Remote Indicator – Fire Alarm in Cupboard                       209-0008
                                                                                 Remote Indicator – Fire Alarm Under Floor                       209-0009
                                                                                 Remote Indicator – Fire Alarm in Return Air                     209-0010
                                                                                 Remote Indicator – Fire Alarm in Exhaust Duct                   209-0011
                                                                                 Remote Indicator – Fire Alarm in Supply Air Duct                209-0012
                                                                                 Remote Indicator – Fire Alarm in Ceiling                        209-0013
                                                                                 Remote Indicator – Fire Alarm Above                             209-0014
                                                                                 Remote Indicator – Fire Alarm                                   209-0020
                                                                                 Remote Indicator – Detector Activated                           209-0023




AUS / PAGE 112    CONTACT AMPAC                              HOME    CONTENTS   SEARCH            ZOOM             PRINT            EXIT
   AUDIO VISUAL SIGNALLING      AMPAC REMOTE INDICATORS



                        Indicator / Buzzer & Indicator / Buzzer with Mute

                        ❚   Alarm activation indicator and buzzer
                        ❚   10mm red flashing LED                                Indicator / Buzzer
                                                                                Voltage                                         24 VDC
                        ❚   Buzzer (with mute facility)
                                                                                Current at 24v                                  27mA
                        ❚   Modern styling                                      LED flash rate                                   45 per minute
                                                                                Buzzer                                          3.8kHz @ 114dBA
                                                                                Size                                            70H x 110W x 10D mm
                                                                                Weight                                          64g

                                                                                Indicator / Buzzer with Mute
                                                                                Voltage                                         24 VDC
                                                                                Current at 24v                                  43mA
                                                                                LED flash rate                                   45 per minute
                                                                                Buzzer                                          3.8kHz @ 114dBA
                                                                                Size                                            70H x 110W x 10D mm
                                                                                Weight                                          89g

                                                                                 Flashing Indicator / Buzzer                                     209-0017
                                                                                 Flashing Indicator / Buzzer with Mute Switch                    209-0016




AUS / PAGE 113    CONTACT AMPAC                              HOME    CONTENTS   SEARCH               ZOOM           PRINT          EXIT
   AUDIO VISUAL SIGNALLING      AMPAC ALARM ACKNOWLEDGEMENT FACILITY (AAF)



                        Alarm Acknowledgement Facility

                        The Alarm Acknowledgment Facility (AAF) is a loop powered addressable
                        device that helps reduce the costly consequence of an unwanted alarm.   Operating Voltage                              21 to 28 VDC (loop powered)
                                                                                                Quiescent Current                              900μA at 24VDC
                                                                                                Alarm Current                                  <8mA at 24VDC
                        ❚   Loop Powered Addressable Device                                     Address Setting                                1 to 126
                        ❚   Built in Short Circuit Isolator                                     Dimension                                      Single gang Clipsal plate
                        ❚   Easy configuration of Acknowledge and Investigate periods            Material                                       High impact ABS (white)
                        ❚   Event logging of AAF sequence                                       Weight                                         45 grams
                        ❚   Allows a group of detectors to be assigned to a nominated AAF
                        ❚   Aesthetically pleasing single gang Clipsal 2000 wall plate           Alarm Acknowledgement Facility – Vertical                            226-0002
                        ❚   Investigate status displayed at FACP and all associated LCDA’s       Alarm Acknowledgement Facility – Horizontal                          226-0004
                        ❚   Audible warning is 75dB @ 1m from the built in buzzer
                        ❚   On board visual indication for “polling”, Fire and Fault status
                        ❚   Remote ‘Hush’ button input terminals available

                        Approvals: AS7240 and AS4428




AUS / PAGE 114    CONTACT AMPAC                               HOME              CONTENTS        SEARCH              ZOOM          PRINT               EXIT
   AUDIO VISUAL SIGNALLING      KLAXON SONOS SOUNDER BEACON



                        Sonos Sounder Beacon

                        A general purpose electronic sounder beacon for fire, security and
                        industrial applications. Deep base units have weatherproof protection to   Audibility at 1m (tone dependent)            Up to 106dB (A)
                                                                                                   Tones                                        32
                        IP65 and can be used in all locations both indoors and outdoors. A full
                                                                                                   Voltage                                      17-60V DC
                        faced, translucent sounder case rather than a separate add-on beacon       Current                                      4-45mA (sounder)
                        gives a much larger lens area and a greater spread of light.                                                            5mA (beacon)
                                                                                                   IP Rating                                    IP65 (deep base)
                        ❚   Simple `First Fix` installation – TimeSaver base                       Operating temperature                        -25°C to +70°C
                        ❚   Quick connect/disconnect                                               Weight                                       215 grams (shallow base)
                        ❚   Tone and volume can be preset or adjusted off-base                                                                   250 grams (deep base)
                        ❚   Weatherproof to IP65 (deep base units)
                        ❚   Low current LED beacon                                                  Red Lens Sonos LED Beacon, shallow base                      18-980500-AMP
                        ❚   Sounder and beacon can be controlled separately                         Red Lens Sonos LED Beacon, deep base                         18-980501-AMP
                                                                                                    Clear Lens Sonos LED Beacon, shallow base, red LEDs          18-980607-AMP
                                                                                                    Clear Lens Sonos LED Beacon, deep base, red LEDs             18-980608-AMP
                        Approvals: EN54-3/LPCB




AUS / PAGE 115    CONTACT AMPAC                              HOME               CONTENTS           SEARCH             ZOOM             PRINT              EXIT
   AUDIO VISUAL SIGNALLING      ELECTRONIC SOUNDERS



                        Vector Sounder

                        ❚ AS1670.4 – signal only
                        ❚ Externally powered - low current consumption                              Operating voltage                          8 to 35 VDC
                                                                                                    Supply current Evac                        15mA @ 24VDC
                        ❚ Volume control adjustment
                                                                                                    Supply current Alert                       8 mA @ 24VDC
                        ❚ Built-in synchronising circuitry with sounders on the same circuit        Signal output                              AS1670.4 – signal only
                        ❚ Can be installed as a sounder base for Apollo detectors or a surface      Max. Output level                          91 dBA @ 1 metre with detector
                          mount sounder when used in conjunction with the optional lid              Evac                                       93 dBA @ 1 metre with lid
                        ❚ Low profile                                                                Volume control                             -30dBA
                        ❚ Available as standard with an XP95 universal base fitted (complete with    IP rating                                  IP42
                          opto - interface board) so the sounder can be controlled via the remote   Temperature range                          -20 to + 70°C
                          LED output of the XP95 detector                                           Construction                               ABS
                                                                                                    Dimension (mm)                             106Ø x 35h (Sounder & lid only)
                        Approvals: AS1670.4
                                                                                                     Vector Sounder                                                    205-0077
                                                                                                     Vector Sounder Lid                                                205-0017




                        Vantage Sounder

                        ❚   Selectable signals to AS1670.4
                        ❚   High output level – up to 100 dB                                        Voltage                                    12 to 35 VDC
                                                                                                    Volume setting                             Low         Med       High
                        ❚   3 selectable output levels
                                                                                                    Current (mA @ 27VDC )                      7           12        19
                        ❚   Low current consumption for rated output                                Sound Output (dB @ 1m)                     85          95        100
                        ❚   2 or 3 wire configuration                                                Signals                                    AS1670.4
                        ❚   Automatic signal changeover facility                                    Size (shallow base)                        94 Dia x 85 H mm
                        ❚   Excellent lateral sound dispersion                                      Size (deep base)                           93 Dia x 102 H mm
                        ❚   Built-in synchronising circuitry                                        Temperature range                          -20°C to +70°C
                        ❚   Surface mounted                                                         Humidity                                   0 to 95%
                        ❚   Quick-fit deep base option                                               IP Rating (shallow)                        IP43
                        ❚   Head to base locking                                                    IP Rating (deep)                           IP65
                                                                                                    Weight                                     193 grams (deep base +5g)
                        Approvals: AS1670.4
                                                                                                     Vantage Sounder Red with Shallow Base                             205-0062
                                                                                                     Vantage Sounder White with Shallow Base                           205-0063
                                                                                                     Deep Base Only Red                                                205-0064
                                                                                                     Deep Base Only White                                              205-0065


AUS / PAGE 116    CONTACT AMPAC                              HOME              CONTENTS             SEARCH             ZOOM           PRINT           EXIT
   AUDIO VISUAL SIGNALLING      ELECTRONIC SOUNDER/BEACONS



                        Vantage Combi

                        ❚   Signals to AS1670.4
                        ❚   High brightness LED strobe                                       Voltage                                  18 to 35 VDC
                                                                                             Volume setting                           Low         Med       High
                        ❚   High output level – up to 100dB
                                                                                             Current (mA @ 27VDC )                    11          18        30
                        ❚   3-level selectable sound output levels                           Sound Output (dB @ 1m)                   85          95        100
                        ❚   Low current consumption less than 70mA                           Signal                                   AS1670.4
                        ❚   2 or 3-wire configuration                                         Flash rate                               1 per sec
                        ❚   Automatic signal changeover facility                             Size (shallow)                           93 Dia x 90 H mm
                        ❚   ABS plastic – available in red or white                          Size (deep)                              93 Dia x 107 H m
                        ❚   Excellent lateral sound dispersion                               Temperature range                        -20°C to +70°C
                        ❚   Built-in synchronising circuitry                                 Humidity                                 0 to 95%
                        ❚   Surface mounted                                                  IP Rating (shallow)                      IP43
                                                                                             Weight                                   221 grams (deep base +5g)
                        ❚   Quick-fit lockable base (both shallow and deep base)

                        Approvals: AS1670.4                                                   Vantage Combi Red with Shallow Base                           205-0066
                                                                                              Vantage Combi White with Shallow Base                         205-0067
                                                                                              Deep Base Only Red                                            205-0064
                                                                                              Deep Base Only White                                          205-0065




AUS / PAGE 117    CONTACT AMPAC                              HOME                 CONTENTS   SEARCH           ZOOM            PRINT         EXIT
   ANCILLARIES              POWER SUPPLIES



                                    MultiAmp PSU

                                    The MultiAmp PSU is a general purpose regulated power supply unit.
                                                                                                             Mains Supply                           190 – 264 VAC
                                                                                                             Operating Voltage                      27.5 VDC ± 0.2 VDC
                                    ❚   Available in 2A and 3A versions
                                                                                                             Supply Current                         2A Current limited (2Amp Version)
                                    ❚   Fault Relay Output                                                                                          3A Current limited (3Amp Version)
                                    ❚   Fault indicator and Resettable Buzzer                                Operating Temperature                  0°C to +40°C
                                    ❚   Earth monitoring                                                     Relative Humidity                      25% - 75%
                                    ❚   Available in ABS (BX1)                                               Battery Capacity:
                                    ❚   Available in Metal cabinets (BX10) shallow and deep versions         BX1 and BX10                           2 x 7Ahr 12V Sealed Lead Acid
       MultiAmp PSU ABS                                                                                      BX10 Deep Cabinet                      2 x 12Ahr 12V Sealed Lead Acid
                                    ❚   2.5mm² cable terminals
                                                                                                             Maximum Charge Current                 400mA (2A) 600mA (3A)
                                    A set of two 7Ahr batteries may be housed in the BX1 and BX10 standard   Fault Relay                            NO,C,NC
                                                                                                                                                    Contact rating: 1A @ 30VDC
                                    cabinet and a set of two 12Ahr batteries in the BX10 deep cabinet.
                                                                                                             Dimensions:
                                    (Maximum size based on Ampac battery specifications)                      ABS Cabinet (BX1)                      300mm (H) x 360mm (W) x 100mm (D)
                                                                                                             Metal Cabinet (BX10)                   300mm (H) x 360mm (W) x 100mm (D)
                                    The unit incorporates temperature sensing and compensation whereby a     Metal Cabinet (BX10 DEEP)              300mm (H) x 360mm (W) x 200mm (D)
                                    change in ambient temperature adjusts the battery charging voltage.
                                                                                                              MultiAmp PSU 2A AS/EN Version (ABS BX1)                         4510-2110
                                    The power supply will signal a Low Batt fault at 21.3 VDC.                MultiAmp PSU 3A AS/EN Version (ABS BX1)                         4510-2120
                                                                                                              MultiAmp PSU 2A AS/EN Version (Metal BX10)                      4510-2210
                                    Approvals: Complies with AS4428/AS7240                                    MultiAmp PSU 3A AS/EN Version (Metal BX10)                      4510-2220
       MultiAmp PSU Metal                                                                                     MultiAmp PSU 2A AS/EN Version (Metal BX10 Deep Cabinet)         4510-2310
                                                                                                              MultiAmp PSU 3A AS/EN Version (Metal BX10 Deep Cabinet)         4510-2320
                                                                                                              BX10 Surround                                                  ENC3016-A




AUS / PAGE 118                CONTACT AMPAC                               HOME               CONTENTS        SEARCH              ZOOM         PRINT            EXIT
   ANCILLARIES   POWER SUPPLIES



                         FastSense Power Supply Unit

                         ❚   2A power supply (incorporating battery charger)
                         ❚   Status indication – “POWER ON”, “BATTERY HIGH”, “BATTERY LOW”,        Operating voltage                            240 VAC
                                                                                                   Output voltage                               27 VDC
                             “BATTERY FAIL”
                                                                                                   Max output current                           2 Amps @ 27.6 VDC
                         ❚   Battery test facility                                                 Battery capacity:
                         ❚   Termination for power supply output – Clearly labelled and adequate   FastSense 25 & FastSense 100 versions        7 Ah
                             amount of room to terminate                                           FastSense PLUS version                       12 Ah
                         ❚   Panel knockouts – top, side and rear of cabinet                       Dimensions:
                         ❚   Optional 6A power supply / battery charger may be fitted to the        FastSense 25 & FastSense 100 versions        300 H x 350 W x 130 D mm
                             FastSense PLUS version                                                FastSense PLUS version                       320 H x 500 W x 160 D mm
                                                                                                   Material                                     1.6 mm Mild steel
                                                                                                   Finish                                       Powder coated Oyster Grey

                                                                                                    FastSense PSU – FastSense 25 & FastSense 100 versions             216-0065
                                                                                                    FastSense PSU – FastSense PLUS version                            216-0066




AUS / PAGE 119     CONTACT AMPAC                              HOME             CONTENTS            SEARCH             ZOOM             PRINT            EXIT
   ANCILLARIES   Manual Call Points – Conventional



                          Manual Call Point – ACP-04

                          ❚ Double terminal, wire protected connectors for independent input and
                            output connections when looping to other devices                       Current Rating                                 3A @ 12/24 VDC
                                                                                                                                                  1.5A @ 48 VDC
                          ❚ Protective film prevents glass from splintering when broken
                                                                                                   Size                                           H 88 x W 88 mm
                          ❚ Open or close circuit operation                                                                                       D 59 mm – surface mounted
                          ❚ 20 mm conduit entries                                                                                                 D 27 mm – flush mounted
                          ❚ Testing and resetting the unit with key supplied                       Switch Type                                    Single pole micro
                          ❚ High reliability micro-switch operation                                Cable termination                              6 x 2.5mm2 screw
                          ❚ Manufactured from high impact plastic and resistant to heat            In-Line Resistor                               470Ω (N/O operation only)
                          ❚ 470Ω in-line resistor                                                  Material                                       High impact ABS
                                                                                                   Operating Temperature                          -5°C to +70°C
                                                                                                   Humidity                                       0 – 95% non-condensing
                                                                                                   IP rating                                      IP 24D
                                                                                                   Weight                                         153 grams

                                                                                                    Manual Call Point – ACP-04 Red                                     213-0060
                                                                                                    Manual Call Point – ACP-04 Yellow                                  213-0061
                                                                                                    Manual Call Point – ACP-04 White                                   213-0062
                                                                                                    Manual Call Point – ACP-04 Green                                   213-0063
                                                                                                    Manual Call Point – ACP-04 Protective Cover                        213-0057
                                                                                                    Manual Call Point – ACP-04 Glass                                   213-0058




AUS / PAGE 120     CONTACT AMPAC                             HOME              CONTENTS            SEARCH            ZOOM              PRINT            EXIT
   ANCILLARIES   Manual Call Points



                          Manual Call Point – Conventional FP2

                          ❚   Re-setable operation
                          ❚   No broken glass or frangible element to replace                Contact rating                              5A @ 30 VDC
                                                                                                                                         10A @ 250 VAC
                          ❚   Tested by actual operation
                                                                                             Size (surface mount)                        87H x 87 W x 54 D mm
                          ❚   Fluorescent band indicates call point has been operated        Size (flush mount)                           87H x 87 W x 16 D mm
                          ❚   Open or closed circuit operation                               Switch type                                 Single pole
                          ❚   Surface and Flush mountable                                    Material                                    High impact ABS
                          ❚   Transparent lift up cover available                            Operating Temperature                       -10°C to +70°C
                                                                                             IP rating                                   IP44
                                                                                             Weight                                      200 grams

                                                                                              FP2 Red                                                           213-0021
                                                                                              FP2 White                                                         213-0022
                                                                                              FP2 Protective Cover                                              213-0023




                          Manual Call Point – Conventional Weatherproof

                          ❚ Suitable for outdoor use                                         Contact rating                              5A @ 24 VDC
                          ❚ Hermetically sealed switches                                     Size                                        110H x 110W x 65Dmm
                          ❚ Back box supplied                                                Switch type                                 Single Pole
                                                                                             Material                                    High Impact ABS
                                                                                             Temperature range                           -10°C to +70°C
                                                                                             IP rating                                   IP67
                                                                                             Weight                                      200 g

                                                                                              Manual Call Point – Conventional Weatherproof                     213-0041




AUS / PAGE 121     CONTACT AMPAC                                HOME              CONTENTS   SEARCH              ZOOM           PRINT          EXIT
   ANCILLARIES   Manual Call Points



                          XP95 Manual Call Point

                          The XP95 Manual Call Point is compliant with EN54-11. The address of each
                          call point is set at the commissioning stage by means of a seven segment    Voltage                                           17-28 VDC
                                                                                                      Quiescent current                                 100μA at 24VDC
                          DIL switch. The device features plug and play terminal connections and a
                                                                                                      Alarm current                                     4mA
                          resettable element.                                                         Address method                                    7 segment DIL switch
                                                                                                      Size (surface mount)                              93H x 89W x 59.5D mm
                          ❚   Plug-and-play terminal connectors for fast wiring                       Operating temperature                             -20°C to +60°C (no icing)
                          ❚   Allows wiring continuity testing before fitting                          Relative humidity                                 0-95% (non condensing)
                          ❚   Isolated version available                                              IP rating                                         IP45
                          ❚   Reports an alarm in under 0.2 seconds                                   Weight                                            190 grams
                          ❚   Resettable element
                                                                                                       XP95 Manual Call Point (Surface)                                             213-0050
                          Approvals: AS1670.1 and EN54-11                                              XP95 Manual Call Point with Isolator (Surface)                               213-0051
                                                                                                       XP95 Manual Call Point Protective Cover                                      213-0064




                          Intelligent Waterproof Manual Call Point

                          The Intelligent Waterproof Manual Call Point has been designed for use
                          outdoors and in places where moisture can occur.                            Voltage                                           17-28 VDC
                                                                                                      Quiescent current                                 230μA
                                                                                                      Alarm current                                     2mA
                          ❚   Plug and play terminal connections for fast wiring                      Address method                                    7 segment DIL switch
                          ❚   Allow wiring continuity testing before fitting                           Size (surface mount)                              87H x 87W x 54D mm
                          ❚   Isolated version available                                              Operating temperature                             -20°C to +70°C (no icing)
                          ❚   Resettable element                                                      Relative humidity                                 0-95% (non condensing)
                                                                                                      IP rating                                         IP67
                          Approvals: AS1670.1 and EN54-11                                             Weight                                            400 grams

                                                                                                       Intelligent Waterproof Manual Call Point                                     213-0066
                                                                                                       Intelligent Waterproof Manual Call Point with Isolator                       213-0067




AUS / PAGE 122     CONTACT AMPAC                                 HOME              CONTENTS           SEARCH             ZOOM              PRINT                EXIT
   ANCILLARIES   Manual Call Points



                          XP95 Intrinsically Safe Manual Call Point

                          The XP95 IS Manual Call Point is based on the standard weatherproof model.
                          It features an ‘interrupt’ facility to provide fast response to an alarm.    Voltage                                       14 to 22 VDC
                                                                                                       Quiescent current                             230uA
                                                                                                       Alarm current                                 2mA
                          ❚ Reports an alarm in under 0.2 seconds                                      Address method                                7 segment DIL switch
                          ❚ Waterproof                                                                 Size                                          124H x 124W x 60D mm
                          ❚ IP67                                                                       Operating temperature                         -20°C to +60°C (no icing)
                                                                                                       Humidity                                      0 to 95%
                          Approvals: AS1670.1 and EN54-11                                              IP rating                                     IP67
                                                                                                       Weight                                        400 grams
                                                                                                       Classification                                 E Ex ia IIc T5

                                                                                                        XP95 Intrinsically Safe Manual Call Point                           55100-940




AUS / PAGE 123     CONTACT AMPAC                               HOME              CONTENTS              SEARCH             ZOOM               PRINT          EXIT
   ANCILLARIES   Fittings



                            Wall Boxes

                            ❚ Used for flush mounting devices such as manual call points
                              and sounders                                                  Size           Metal               72H x 72W x 47D mm
                                                                                                           Plastic             72H x 72W x 35D mm
                            ❚ Suitable for MCP models ACP-01 & FP2
                                                                                            Weight         Metal               153 grams
                            ❚ Suitable for ‘Vara’ sounder                                   Plastic                            47 grams

                                                                                             Wall Box Metal                                         268-0002
                                                                                             Wall Box Plastic                                       268-0009




AUS / PAGE 124      CONTACT AMPAC                               HOME             CONTENTS   SEARCH              ZOOM   PRINT         EXIT
   ANCILLARIES   Occupant Warning Systems



                         Amplified Sound System – EV20

                         ❚   Single zone amplified sound system for occupant warning
                         ❚   Signals to AS1670.4                                             Voltage                                  27 VDC
                                                                                             Quiescent current                        41mA
                         ❚   Open and short circuit speaker line monitoring and protection
                                                                                             Max current                              650mA
                         ❚   Manual control / isolation facility                             Max output power                         20 Watts
                         ❚   Volt free Fire Alarm Control Panel input (latching)             Output voltage                           100 VAC RMS
                         ❚   Adjustable volume control                                       Signals                                  AS1670.4
                         ❚   Automatic changeover between tones                              Size - main board                        180L x 82W x 55H mm
                         ❚   Fault output                                                    Size - controls                          90L x 35W x 40H mm
                         ❚   P.A. microphone input (optional)                                Tone timeout                             0, 30, 60, 120, 180, 240
                         ❚   Verbal messaging (optional)                                                                              or 300 secs
                                                                                             Weight                                   690 grams
                         Approvals: AS1670.4
                                                                                              Amplified Sound System – EV20                                  222-0020
                                                                                              Verbal Message                                                222-0026
                                                                                              EV20/60/120 Microphone Upgrade Kit                            222-0007




                         Amplified Sound System – EV40

                         ❚   Single zone amplified sound system for occupant warning
                         ❚   Signals to AS1670.4                                             Voltage                                  27 VDC
                                                                                             Quiescent current                        140mA
                         ❚   Open and short circuit speaker line monitoring and protection
                                                                                             Max current                              2.8A
                         ❚   Manual control / isolation facility                             Max output power                         40 Watts
                         ❚   Volt free Fire Alarm Control Panel input (latching)             Output voltage                           100 VAC RMS
                         ❚   Adjustable volume control                                       Signals                                  AS1670.4
                         ❚   Automatic changeover between tones                              Size - main board                        170L x 90W x 60H mm
                         ❚   Fault output                                                    Size - control card                      90L x 35W x 40H mm
                         ❚   P.A. microphone input (optional)                                Tone timeout                             0, 30, 60, 120, 150, 180, 210,
                         ❚   Verbal messaging (optional)                                                                              240, 270, 300, 360, 420, 480
                                                                                                                                      or 540 secs
                                                                                             Weight                                   900 grams
                         Approvals: AS1670.4
                                                                                              Amplified Sound System – EV40                                  222-0021
                                                                                              Verbal Message                                                222-0013
                                                                                              EV40 Microphone Upgrade                                       294-0001




AUS / PAGE 125     CONTACT AMPAC                              HOME              CONTENTS     SEARCH                ZOOM       PRINT       EXIT
   ANCILLARIES   Occupant Warning Systems



                         Amplified Sound System – EV60

                         ❚   Single zone amplified sound system for occupant warning
                         ❚   Signals to AS1670.4                                             Voltage                                  27 VDC
                                                                                             Quiescent current                        140mA
                         ❚   Open and short circuit speaker line monitoring and protection
                                                                                             Max current                              3.9A
                         ❚   Manual control / isolation facility                             Max output power                         60 Watts
                         ❚   Volt free Fire Alarm Control Panel input (latching)             Output voltage                           100 VAC RMS
                         ❚   Adjustable volume control                                       Signals                                  AS1670.4
                         ❚   Automatic changeover between tones                              Size - main board                        180L x 82W x 55H mm
                         ❚   Fault output                                                    Size - controls                          90L x 35W x 40H mm
                         ❚   P.A. microphone input (optional)                                Tone timeout                             0, 30, 60, 120, 180, 240 or
                         ❚   Verbal messaging (optional)                                                                              300 secs
                                                                                             Weight                                   2.75 kg
                         Approvals: AS1670.4
                                                                                              Amplified Sound System – EV60                                  222-0022
                                                                                              Verbal Message                                                222-0013
                                                                                              EV20/60/120 Microphone Upgrade Kit                            222-0007




                         Amplified Sound System – EV120

                         ❚   Single zone amplified sound system for occupant warning
                         ❚   Signals to AS1670.4                                             Voltage                                  27 VDC
                                                                                             Quiescent current                        260mA
                         ❚   Open and short circuit speaker line monitoring and protection
                                                                                             Max current                              8A
                         ❚   Manual control / isolation facility                             Max output power                         120 Watts
                         ❚   Volt free Fire Alarm Control Panel input (latching)             Output voltage                           100 VAC RMS
                         ❚   Adjustable volume control                                       Signals                                  AS1670.4
                         ❚   Automatic changeover between tones                              Size - main board                        170L x 210W x 85H mm
                         ❚   Fault output                                                    Size - controls                          90L x 35W x 40H mm
                         ❚   P.A. microphone input (optional)                                Tone timeout                             0, 30, 60, 120, 180, 240 or
                         ❚   Verbal messaging (optional)                                                                              300 secs
                                                                                             Weight                                   3.7 kg
                         Approvals: AS1670.4
                                                                                              Amplified Sound System – EV120                                 222-0023
                                                                                              Verbal Message                                                222-0013
                                                                                              EV20/60/120 Microphone Upgrade Kit                            222-0007




AUS / PAGE 126     CONTACT AMPAC                              HOME              CONTENTS     SEARCH              ZOOM         PRINT       EXIT
   ANCILLARIES   Electro-Magnetic Door Holders



                          ADH-01 – Electro-Magnetic Door Holder

                          ❚   Available in 24VDC with 50kg/50N holding force
                          ❚   Release switch on housing                                     Operating Voltage                           15 to 29 VDC
                                                                                            Operating Current                           55mA @ 24 VDC
                          ❚   Designed for surface mounted
                                                                                            Holding Force                               50kg
                          ❚   Adjustable door mounted keeper plate                          Housing                                     White High Temperature ABS
                          ❚   Separate screw terminals to maintain monitoring integrity     Operating Temperature                       -10° to +55° C
                          ❚   Rear and side cable access                                    Dimension (mm)                              100h x 100w x 50d
                                                                                            IP rating                                   IP 51
                                                                                            Weight                                      750 g
                                                                                            Approval                                    C-Tick

                                                                                             ADH-01 – Electro-Magnetic Door Holder, 50kg/50N holding force    212-0012




                          H1330 – Magnet

                          ❚   50kg/50N holding force
                          ❚   Retains fire doors in the open position                        Voltage                                     24 VDC
                                                                                            Quiescent current                           60mA at 24 VDC
                          ❚   In built residual magnetism release pin
                                                                                            Size exc anvil                              65H x 65W x 35D mm
                          ❚   Fail safe operation                                           Weight inc anvil                            420 grams

                                                                                             H1330 – Magnet, 50kg/50N holding force                           212-0002




AUS / PAGE 127     CONTACT AMPAC                                HOME             CONTENTS   SEARCH              ZOOM          PRINT            EXIT
   ANCILLARIES   Electro-Magnetic Door Holders



                          H1360 – Surface Mount

                          ❚   Retains fire doors in the open position
                          ❚   Cover in black ABS                                            Voltage                                    24 VDC
                                                                                            Quiescent current                          100mA at 24 VDC
                          ❚   Container in white aluminium
                                                                                            Size exc anvil                             95H x 95W x 40D mm
                          ❚   In built residual magnetism release pin                       Weight inc anvil                           700 grams
                          ❚   In built manual release switch
                          ❚   Fail safe operation                                            H1360 – Surface Mount, 50kg/50N holding force                    212-0003
                                                                                             H1360 – Surface Mount, 100kg/100N holding force                  212-0004




                          H1368 – Flush Mount

                          ❚   50kg/50N holding force
                          ❚   Retains fire doors in the open position                        Voltage                                    24 VDC
                                                                                            Quiescent current                          100mA at 24 VDC
                          ❚   Flush Mount
                                                                                            Size exc anvil                             120H x 76W x 41D mm
                          ❚   Cover in aluminium                                            Weight inc anvil                           650 grams
                          ❚   Housing in galvanised steel
                          ❚   In built residual magnetism release pin                        H1368 – Flush Mount, 50kg/50N holding force                      212-0006
                          ❚   Fail safe operation




                          H1369 – Floor Mount

                          ❚   50kg/50N holding force
                          ❚   Retains fire doors in the open position                        Voltage                                    24 VDC
                                                                                            Quiescent current                          60mA at 24 VDC
                          ❚   Black steel bracket, die-cast aluminium mounting
                                                                                            Size exc anvil                             100H x 110W x 80D mm
                          ❚   In built residual magnetism release pin                       Weight inc anvil                           946 grams
                          ❚   In built manual release switch
                          ❚   Fail safe operation                                            H1369 – Floor Mount, 50kg/50N holding force                      212-0001




AUS / PAGE 128     CONTACT AMPAC                                HOME             CONTENTS   SEARCH              ZOOM          PRINT            EXIT
   ANCILLARIES   Electro-Magnetic Door Holders



                          H1370 – Floor or Wall Mount

                          ❚   50kg/50N holding force
                          ❚   Retains fire doors in the open position                           Voltage                                   24 VDC
                                                                                               Quiescent current                         60mA at 24 VDC
                          ❚   Black steel bracket, aluminium support
                                                                                               Size exc anvil Base                       125H x 125W x 15D mm
                          ❚   In built residual magnetism release pin                          Arm 1370/15                               40Dia x 150H mm
                          ❚   In built manual release switch                                   Arm 1370/30                               40Dia x 300H mm
                          ❚   Fail safe operation                                              Weight inc anvil                          1.277 kg

                                                                                                H1370/15 – Floor or Wall Mount – 150mm arm                      212-0007
                                                                                                H1370/30 – Floor or Wall Mount – 300mm arm                      212-0008




                          H1351 – Anvil

                          ❚   Retains fire doors in the open position
                          ❚   Cushioned magnetic support for 50kg electromagnets               Size                                      65H x 64W x 48D mm
                                                                                               Weight                                    18 grams
                          ❚   Swivel adjustment
                                                                                                H1351 – Anvil                                                   212-0009




                          Remote Door Release

                          ❚   Remotely releases fire doors held open by electro magnetic door
                              holder                                                           Size                                      70H x 110W x 10D mm
                                                                                               Weight                                    68 grams

                                                                                                Remote Door Release                                             268-0003




AUS / PAGE 129     CONTACT AMPAC                                HOME            CONTENTS       SEARCH                ZOOM       PRINT          EXIT
   ANCILLARIES   Electro-Magnetic Door Holders



                          MultiAmp-DH

                          The MultiAmp-DH 250mA Door Holder Supply (DHS) provides up to
                          250mA of current at 24 VDC to operate door holders. The unit can operate      Mechanical
                                                                                                        Material                             High Impact ABS
                          as an “Automatic Door Release System” (ADRS) or respond to a secondary
                                                                                                        Finish                               White
                          control.                                                                      Dimension (mm)                       91H X 149W x 40D (Recessed)
                                                                                                                                             91H X 149W x 53D (Surface)
                          When configured as an ADRS, conventional detectors are installed and           Weight                               400g packed
                          connected directly to the DHS. The detection circuit is monitored for
                          alarm, open, or short circuit conditions. The presence of any one of these    Power Supply
                          conditions will deactivate supply to the door holders and cause doors to      Mains Supply Voltage                 230 VAC +/- 10% @ 47-63Hz
                          be released.                                                                  Door Holder Output Voltage           24 VDC @ 250mA
                                                                                                        Operating Temperature                -5° to +45° C
                                                                                                        Relative Humidity                    25% to 95%
                          Alternatively doors may be released by a switched VDC input to the DHS,
                          derived normally from a Fire Alarm Control Panel (FACP) or security system.   Zone Detection Circuit
                          The switched VDC input must be between 8 to 30VDC to release the              No of Zones                          1 (one), 2-wire system
                          doors.                                                                        Zone Monitoring                      Open and short-circuit
                                                                                                        Zone Current Load                    4.8mA max
                          ❚   Mains powered 240vAC supply                                               EOL Value                            3k3 ohm
                          ❚   On board conventional detection zone                                      No of detectors/circuit              40 (Max)
                          ❚   Switches off DH power in alarm condition or atlernatively remote
                              switched input can trigger the door to release                            Input
                                                                                                        Switched VDC Input                   Inactive state: 0 to 2 VDC
                                                                                                                                             Active state: 8 to 30 VDC

                                                                                                         MultiAmp-DH Flush Mount                                      4510-1100
                                                                                                         MultiAmp-DH Surface Mount                                    4510-1101




AUS / PAGE 130     CONTACT AMPAC                                HOME               CONTENTS             SEARCH             ZOOM      PRINT           EXIT
   ANCILLARIES   DOCUMENT CABINETS



                         Document Cabinets

                         AMPAC offers ABS and metal document cabinets designed to complement
                         the range of AMPAC’s fire control panels. The cabinets can hold in excess of   Colour                                   ABS – Cool Grey
                                                                                                                                                Metal – Oyster Grey
                         100 A4 sheets of fire and security information relevant to the premises.
                                                                                                                                                Metal – Arch White
                                                                                                       Dimensions                               ABS – 300H x 360W x 100Dmm
                         The cabinets are fitted with a lockable front door for security and comes                                               Metal – 295H x 356W x 92Dmm
                         complete with an internal key holder bracket to allow easy storage of         IP Rating                                IP30
                         security keys. Whilst the ABS cabinet is available only in cool grey, there   Weight                                   ABS – 1kg
                         is a choice of Oyster Grey or Arch White with the metal cabinet option.                                                Metal – 3kg
                                                                                                       Key Type                                 003 Key
                         ❚   Metal and ABS versions available
                         ❚   Metal version available in Oyster Grey or Arch White                       Document Cabinet ABS – Cool Grey                           4210-0010
                         ❚   Provides the facility to hold documents i.e. Operation and Maintenance     Document Cabinet Metal – Oyster Grey                       4210-0020
                             Manuals                                                                    Document Cabinet Metal – Arch White                        4210-0021
                         ❚   Lockable front door
                         ❚   Internal key holder bracket
                         ❚   Designed to complement the AMPAC range of enclosures




AUS / PAGE 131     CONTACT AMPAC                                HOME               CONTENTS            SEARCH           ZOOM            PRINT         EXIT
   ANCILLARIES             TEST EQUIPMENT



                                      Test Equipment

                                      ❚   Access poles are used with interchangeable heads that fit onto the end
                                          of the pole                                                              Telescopic pole – 6 metre                                           204-0001
                                      ❚   The equipment is suitable for use on a wide range of detectors           Extension pole – 1.3 metre                                          204-0002
                                      ❚   Poles are telescopic, nonconductive, toughened fibreglass                 Universal detector removal tool                                     204-0003
                                      ❚   Light weight and simple to use                                           Aerosol Smoke Dispenser                                             204-0004
                                                                                                                   Heat detector tester – cordless (head only)                         204-0017
                                                                                                                   Smoke detector test set – 8.2 metre                                 204-0009
                                                                                                                   Smoke detector test set – 6.7 metre                                 204-0010
     Telescopic Pole 204-0001                                                                                      Smoke & cordless heat test set – 4.5 metre                          204-0018
                                                                                                                   250ml can of smoke (test set use only)                              204-0014
                                                                                                                   150ml can of smoke (hand held)                                      204-0015
                                                                                                                   Can of smoke for CO detectors (test set use only)                   204-0020
                                                                                                                   Battery Baton for Cordless Tester                                   204-0021




 Aerosol Smoke Dispenser 204-0004             CO Test Can 204-0020            Cordless Heat Detector 204-0017              Head Removal Tool                    Smoke & Cordless Heat Test Set
                                           250ml Smoke Can 204-0014
                                           150ml Smoke Can 204-0015




AUS / PAGE 132                  CONTACT AMPAC                              HOME             CONTENTS              SEARCH             ZOOM              PRINT           EXIT
   ANCILLARIES   TEST EQUIPMENT



                         XP95 Test Set (Loop Manager Apollo)

                         The XP95 Test Set is a self-contained, portable test unit capable of
                         providing a number of useful functions in relation to individual detectors,    Apollo XP95 Test Set                   55000-870EUR
                         ancillary devices or complete circuits of analogue addressable devices in      Ampac XP95 Test Set                        204-0016
                         the Apollo intelligent ranges. The main function of the test set is to help
                         the engineer guarantee correct loop configuration before an active control
                         panel is installed.

                         ❚   User friendly LCD information display
                         ❚   Speedy commissioning
                         ❚   Option for hard copy of results
                         ❚   No unnecessary site visits
                         ❚   Significant cost reductions




                         Discovery Programmer

                         The Discovery Programmer is a portable test and configuration tool for
                         Discovery smoke and heat detectors.                                            Discovery Programmer                      53832-030

                         ❚   Look up the date of manufacture
                         ❚   Check the drift compensation value
                         ❚   Display and change the operating mode
                         ❚   Select/de-select LED flash mode
                         ❚   Tests detectors
                         ❚   Reads approval codes




AUS / PAGE 133     CONTACT AMPAC                               HOME              CONTENTS              SEARCH            ZOOM   PRINT   EXIT
   ANCILLARIES   TEST EQUIPMENT



                         Flame Sensor Test Unit and Case

                         The Flame Sensor Test Kit is a tool which is designed to test flame
                         detectors without the need of real flames.                             Flame Sensor Test Unit and Case                  29600-226

                         ❚   Mimics the characteristics of real flames




AUS / PAGE 134     CONTACT AMPAC                               HOME              CONTENTS     SEARCH            ZOOM             PRINT   EXIT
   ANCILLARIES   Sealed Rechargeable Lead-Acid Batteries



                          Sealed Rechargeable Lead-Acid Batteries

                          Ampac sells a comprehensive battery range for all applications requiring a
                          reliable rechargeable power source. The wide range of sizes coupled with     Voltage (nominal)                               12 VDC
                                                                                                       Capacity                                        Various
                          good cycling ability make them perfect for critical systems such as fire
                                                                                                       Operating temperature – charging                -15°C to +50°C (no icing)
                          alarm and emergency warning systems. Designed using VRLA technology,                                – discharging            -20°C to +60°C (no icing)
                          negating the need to add water, these batteries can be applied in many       Life expectancy – standby use                   3 to 5 years
                          critical systems requiring reliable reserve power. Available as 12V or for   Terminal                                        Quick disconnect or receptacle M5
                          very large systems 2 volt cells (x12).
                                                                                                        12 VOLT 1.2 AH SLA 50BP1.212                                            210-0008
                          Consideration should be given to the battery space available. If in doubt,    12 VOLT 3.0 AH 5LA 50BP312                                              210-0006
                          consult your local customer service office.                                     12 VOLT 7AH SLA 50BP712                                                 210-0016
                                                                                                        12 VOLT 12 AH SLA 50BP1212                                              210-0010
                                                                                                        12 VOLT 17AH SLA 50BP1712                                               210-0003
                          ❚   VRLA technology (Valve Regulated Lead-Acid)
                                                                                                        12 VOLT 26AH SLA 50BP2612                                               210-0012
                          ❚   No topping up
                                                                                                        12 VOLT 40AH SLA 50BP4012                                               210-0013
                          ❚   Wide capacity range                                                       12 VOLT 65AH 50BP6512                                                   210-0015
                          ❚   Can be operated in any position without leakage
                          ❚   Long operating life                                                       12 VOLT 90AH SLA 50BP9012                                               210-0002
                          ❚   Many capacities available                                                 BATT 12 VOLT 100AH E12V100                                              210-0009
                          ❚   2 volt cells – very large systems                                         12VOLT 120AH 50BP12012                                                  210-0022

                                                                                                        Extra large 12 Volt (consideration of battery cabinet space required)
                                                                                                        12V 160AH 50BP16012                                                     210-0017
                                                                                                        12 VOLT 230AH SLA 50BP23012                                             210-0011

                                                                                                        Extra large 12 Volt (consideration of battery cabinet space required)
                                                                                                        2 Volt Cells (12 x Cells are required)
                                                                                                        210-0018 2VOLT 250AH UPZ 2-250                                          210-0018
                                                                                                        210-0019 2VOLT 300AH UXL-330-2                                          210-0019
                                                                                                        210-0020 2VOLT 550AH UXL-550-2                                          210-0020




AUS / PAGE 135     CONTACT AMPAC                                HOME               CONTENTS            SEARCH             ZOOM              PRINT              EXIT
  CONTACT        Customer Service Offices



                             WESTERN AUSTRALIA                  NEW SOUTH WALES &                       SOUTH AUSTRALIA
                             7 Ledgar Road                      AUSTRALIAN CAPITAL TERRITORY            63 Grange Road
                             Balcatta                           Unit B 28-32 Egerton Street             Welland
                             Western Australia 6021             Silverwater                             South Australia 5032
                                                                New South Wales 2128
                             Telephone: +618 9201 6110                                                  Telephone: +618 8340 9519
                             Fax: +618 9201 6111                Telephone: +612 9648 4933               Fax: +618 8340 4218
                             Email: info@ampac.net              Fax: +612 9648 4932                     Email: info.sa@ampac.net
                             Mobile: 0406 383 072               Email: info.nsw@ampac.net               Mobile: 0400 835 969
                                                                Mobile: 0417 986 847
                             Contact:                                                                   Contact:
                             Neil Biggar                                                                Lester Gaskin
                                                                Contact:
                             Dave Thomas                                                                Daniel Tsiavlis
                                                                David Lehn
                             Lukasz Swietojanski                                                        Adam Richards
                                                                Wes McMillan
                                                                Stuart Chance
                             VICTORIA & TASMANIA                                                        NORTHERN TERRITORY
                             422 Johnston Street                                                        63 Grange Road
                                                                QUEENSLAND
                             Abbotsford                                                                 Welland
                                                                1/53 Parramatta Road,
                             Victoria 3067                                                              South Australia 5007
                                                                Underwood,
                             Telephone: +613 9416 4111          Queensland 4119                         Telephone: +618 8340 9519
                             Fax: +613 9416 4227                                                        Fax: +618 8340 4218
                                                                Telephone: +617 3208 9299
                             Email: info.vic@ampac.net                                                  Email: m.cavenagh@ampac.net
                                                                Fax: +617 3208 9355
                             Mobile: 0417 331 473                                                       Mobile: 0451 632 965
                                                                Email: info.qld@ampac.net
                             Contact:                           Mobile: 0438 909 584                    Contact:
                             Tom Stroumos                                                               Matt Cavenagh
                                                                Contact:
                             Nick Vangeli
                                                                Dave McIntosh
                             Ian Siemonek
                                                                Shane Croaker
                                                                Eli Kirwan




AUS / PAGE 136         CONTACT AMPAC                     HOME     CONTENTS              SEARCH   ZOOM         PRINT            EXIT
   CONTACT       Head Office & Administration




                                                                HEAD OFFICE & ADMINISTRATION

                                                                Ampac Technologies Pty Ltd
                                                                7 Ledgar Road
                                                                Balcatta
                                                                Western Australia 6021

                                                                Telephone:
                                                                +618 9242 3333
                                                                Fax:
                                                                +618 9242 3334
                                                                Email:
                                                                info@ampac.net
                                                                Web:
                                                                www.ampac.net




                                                                CLICK HERE TO VIEW CUSTOMER SERVICE OFFICES




                                                                As part of Ampac’s commitment to continuous improvement, specifications
                                                                may change without notice.
                                                                Version AUS/01-12-10

                                                                Planned, written, designed and produced by Right Angle • www.rightangle.co.uk




AUS / PAGE 137         CONTACT AMPAC          HOME   CONTENTS           SEARCH              ZOOM             PRINT           EXIT

								
To top