Schneider Electric 24th_Navinesh

Document Sample
Schneider Electric 24th_Navinesh Powered By Docstoc
					Intelligent Solutions to improve the efficiency
of your power distribution network


Navinesh Chaudary
Regional Manager
Asia Pacific Operation Divion



24th March 2011
FIJI
HOLIDAY INN
Renewable Energy & Energy Efficiency technology &
financing workshop
What is Efficiency ??
What is Efficiency ???




                               Do more with LESS !!




 Comparison of what is actually produced or performed with what can be
 achieved with the same consumption of resources (money, time, labor,
 etc.).
Efficiency in your power
network
 • Financial           • Downtime reduction        • Energy Efficiency


Reduce :
                        Increase availability
 Installation costs
                        Reduce costs associated
   - save space
                        with fault-finding and
   - save time
                        trouble-shooting
 Base product costs
 Running costs
 Upgrading costs




                                   SAVE COST
                                    BE GREEN
Savings are available today…

 100%
                                                                                  • Up to 8% per year is lost without
                                                                                  monitoring and maintenance program
                                                                                  • Up to 12% per year is lost without
                 installation (10 to 15%)
                  Efficient devices and




                                                                                  regulation and control systems
                                            automation (5 to 15%)
                                             Optimized usage via




  70%
   Consumption




                                                                    Monitoring & Maintenance
                                                                            (2 to 8 %)


                                                                                                               Time
 … but savings can be lost
 quickly…
 ● Unplanned, unmanaged shutdowns of equipment and processes
 ● Lack of automation and regulation (motors, heating)
 ● No continuity of behaviours


100%
                                                                                      Up to 8% per year is
                                                                                      lost without
                                                                                      monitoring and
              Efficient devices
               and installation




                                                                                      maintenance
                                  Optimized usage
                                   via automation




70%                                                                                   program
Consumption




                                                                                      Up to 12% per year
                                                                                      is lost without
                                                    Monitoring & Maintenance          regulation and
Energy




                                                                                      control systems


                                                                               Time
Efficiency solutions
from Schneider Electric

     • Intelligent switching/protection solutions
     • Protection co-ordination
     • Power factor correction
     • Harmonic mitigation
     • VSDs
     • Efficient Power Distribution - Busduct
     • Integration solutions
                                         Intelligent Switching/Protection Solutions


Intelligent Switching and Protection

                                       The „ Energy Efficiency ‟
                                       Circuit Breaker




                Masterpact NT/NW

                                         Compact NSX
                          Intelligent Switching/Protection Solutions



Meet 4 needs …. with 1
solution
Compact and Masterpact

    Protection & safety
    Measurement
    Diagnostics
    Communication
                                             Intelligent Switching/Protection Solutions




1.        Protection & safety
   Improved discrimination with the
    Multi9 miniature circuit breaker range
    ….. 30% cost savings
   Intelligent Co-ordination
   Advanced protection ...
         - ground fault
         - advanced motor protection
         - ZSI : zone sel. Interlocking
   Torque limiting screws
    – Compact NSX
                                                                Intelligent Switching/Protection Solutions


Optimisation of installation solutions
 - cost & functionality


                                         Continuity of                         Cost of
                Customer needs           electrical                            the
                                         energy supply                         electrical
                                                                               installation



                                                                                   Constraint
              Totally co-ordinated
                                                                                   Limitation
              Schneider protection   Discrimination as a    Economical association of
                     devices         standard in the        circuit-breakers through
                                     circuit-breaker ranges Cascading


   • Discrimination / selectivity - guarantees continuity of supply
   • Cascading - optimizes the solution & reduces cost
   • Reflex tripping / current limitation - reduces the stress on the installation
   • Ics = Icu
                                                          Intelligent Switching/Protection Solutions




2.            Measurement
Measurement through integrated trip units
Accurate measurement of electrical parameters
     ● Current,
                               – Power factor,
     ● Voltage,
                               – Energy-KWH,
     ● Frequency,
                               – THD


The FDM - Front Display Module

     Simple ‘plug & play’ device
       –    access to all the micrologic information on
           the front of the switchboard
       –   no tools, no parameter setting
                                           Intelligent Switching/Protection Solutions




2.   Measurement
             Real time monitoring of events
             Local or remote control of circuit breakers
             Signaling of all events and alarms
             Scheduling of maintenance jobs
             Metering and indication of I,U, P, Fq
             Power quality metering, harmonics
             Remote indication of breaker status and position
             Display of settings and measurements on a supervisory
              system
             Programming of alarms, maintenance indicators
                                                         Intelligent Switching/Protection Solutions




3.         Diagnostics
   The "Ready" LED… trip unit ‘Ready’ for protection
    Continuous testing without interrupting system operation

   SDx module - Fault origin identification module
         - Thermal fault indication
         - Prealarm (configurable)
   upto 12 Alarms can be defined
   History and diagnostics files
    –   Temperature
    –   Time stamped event history
                   Intelligent Switching/Protection Solutions



3.   Diagnostics
                                                                  Intelligent Switching/Protection Solutions




4.            Communication
                                                                              Internet
                                                           Firewall


A new communication architecture
“Plug and play”                           Ethernet
                                                                                            RSU, RCU
                                                                                          ION Enterprise
                                                                                            TAC Vista
                                          (TPC/IP/Modbus)
●   communication with the FDM and/or the
                                                             MPS 100
    Modbus interface without any parameter
                                                      EGX 400
    setting
                                                  Modbus
●   use simple RJ45 connectors
                                                                  Modbus IFM interface
●   flexible easily-upgradeable architecture
                                                                            FDM
                                     Masterpact

                                                                                                    Power
                                                                                                    Logic


                                                                                                  Sepam
                                                     Intelligent Switching/Protection Solutions


Conformity to international standards

For the entire range, from circuit breakers to all accessories
IEC / AS
  ● IEC 60947-1-2-3: general - circuit breakers -
    switch-disconnectors
  ● IEC 60947-4: Motor contactors and starters
  ● IEC 60947-5.1 and following: control-circuit
    devices and switching elements; automatic
    control components
Specific
  ● UL / CSA with Compact NSFs and Compact
    NSGs
Marine classification companies
  ● Bureau Veritas, Lloyd's Register of Shipping,
    Det Norske Veritas, etc.
Machines
  ● CNOMO (machine-tools)
  ● EN 60204 / NFC 79-130 (Electrical equipment
    of industrial machines)
                                                                        Intelligent Switching/Protection Solutions


Helps to save the planet

Meets sustainable development requirements

 Eco Conception                         Eco Production                          End of life

Conforms to the RoHS                   Produced on non-polluting          The materials have been
environmental directive                 sites, in conformity with           chosen for treatment,
Can be integrated without               ISO 14001                           recycling and recovery
restriction in a device or                                                  under optimum
                                       Its packaging meets the
installation directly governed by                                           conditions, in accordance
                                        environmental
these regulations                                                           with the European
                                        requirements specified in
                                        the EEC94/62/EC
                                                                            WEEE regulations
                                        directive                          Designed to facilitate
                                                                            removal and recycling at
                                                                            end of life
                                                        Power Quality




What is Power Factor?
                                   power supply authority

   kVAR                             kvar      kW
   Reactive
   Power
                         invoice


              kVA
    kW        Apparent
    Active    Power
    Power

                                           kVA


                                                     end user
                          load
                                    kvar      kW
                                                                             Power Quality



Power Factor Correction
                                                         kvar       kW   Power
                                            invoice                      supply
 Capacitor bank connected to the
                                                                         authority
electrical system

 Utility supplies only KW with less               savings
or no KVAR
                                                      kvar
 Apparent power consumed is
minimised                              Capacitor
                                         bank
 PF is enhanced (increase in
efficiency)                                                   kVA
 System losses are reduced

 Supply capacity is enhanced                                            end user
                                         load
                                                       kvar     kW
                                                                                         Power Quality



Power factor correction




             VARPACT Function Plates

             •   pre-wired assembly, ready to be
                 installed in your switchboard.
             •   100% tested before dispatch.


                        VARSET Automatic PFC Banks
                              ●   Complete packaged solution ready to install
                              ●   Available in wall-mounted and floor-standing version
                              ●   Modular system design – Components
LOOSE                         ●   in IP31 and IP54 versions
COMPONENTS
                                                            Power Quality




Power Quality and Harmonics
          Harmonic disturbances are caused by non-
          linear loads.

          Most electronic loads draw harmonic currents
          and hence induce harmonic voltages in
          electrical networks, e.g. :

             ● Power electronic equipment (rectifier, inverter,
               speed controller, dimmer)
             ● fluorescent lighting
             ● welding machines
             ● data processing equipment (computers &
               peripherals)
                                                                       Power Quality


Effects of harmonics in
electrical systems
                    Effects on installations
                       ● accelerated aging of certain equipment
                         (by heating, vibrations)
                       ● electromagnetic disturbances
                       ● motor overconsumption
                       ● damage capacitor banks
                       ● overloads in the neutral conductor
 Downtime & maintenance

  Efficiency, quality &             Extra costs in terms of equipment, energy
  System capacity                    and productivity


Harmonics are a circumstance of progress and they effect almost every
business in today’s environment…
                                                               Power Quality


Active Harmonic Filtering
solution
Electronic injection of harmonics to cancel source harmonics

Fast response active filters can provide better mitigation

Use of current transformers to measure load current

            Is                   CT
      ~
                       Ia
                                              Z

                        AHF
                                         Load
                                                                Power Quality


Accusine - Active Harmonic
Filters
         Dynamic current injection for harmonic cancellation
         and power factor correction
         C-tick approved, UL & CSA approved
         Filters to the 50th harmonic
         Filters entire network or specific loads depending on
         installation point
          Real time control algorithms
            ● Responds instantly to inrush situations
              (40 micro-sec)
            ● Full response in 8 msec for steady state situations
         IGBT based power electronic technology
                                                                            Power Quality


Accusine - Active Harmonic
Filters                                             Order
                                                               AS off

                                                               % I fund
                                                                           AS on

                                                                           % I fund
                                         At VFD     Fund       100.000%    100.000%
                                        terminals   3            0.038%      0.478%

                                                    5           31.660%      0.674%

     AccuSine                                       7           11.480%      0.679%

     injection                                      9           0.435%       0.297%

                                                    11          7.068%       0.710%

                                                    13          4.267%       0.521%

                                                    15          0.367%       0.052%

                                                    …

                                                    …
                                       Source
                                                    41          0.588%       0.120%
                                       current      43          1.281%       0.337%

                                                    45          0.259%       0.347%

                                                    47          0.427%       0.769%

                                                    49          1.348%       0.590%

The result is a waveform with reduced harmonic      % THD(I)      35.28%      2.67%

content as seen by the upstream electrical system
                                                         Efficient Motor Control



Where are the costs?
 Motor Life cycle cost (average 15 years)
Beyond the initial investment, the key point
is efficient motor   control


                   Energy
                    97%
                 Installation
                 & Maintenance : 2%             1 x Large Motor can
                                                          =
          Investment : 1%                      1 x Month’s Energy Bill
                                   Efficient Motor Control

How to optimise your
installation ?
 use a variable speed     drive
to control your motor

  up to 10% of savings
  ● use the right motor with the
    highest efficiency

   up to 50% of savings
                            Efficient Motor Control




Where to find the savings:




                      Primary target
                                                       Efficient Motor Control


Benefits of using variable
speed drives
• Savings in electricity costs of 15 to over 50% are
  achievable

• Enhanced control performance

• Less mechanical devices = less maintenance

• Reduction of noise pollution

• Reduced mechanical stress (water hammer,
  cavitations, ...)

• Process regulation with PID regulator

• Dedicated quadratic motor control functions

• Very quick return on investment: between 9 and 24
  months

 ECO2 the energy saving simulation tool
                                                            Efficient Power Distribution




 Optimisation of Power Distribution
                      •   Easy & Quick installation
                      •   Lower losses
                      •   Reduction of raw material usage
                      •   High short-circuit withstand, type tested

Busbar                •   Lower voltage drop
trunking              •   Compact & Small dimensions
systems
                      •   100% Reusability of standard elements
                      •   Halogen-free
save
                            - No PVC, No emission of toxic fumes in event of fire
time &
cost                        - Compliance with RoHS directives limiting use of
                              toxic substances
    Integrated EMCS – Engineered
    Solution                                         Reporting by:-
                                                     • GHG - CO2 emission
                                                     • By department / tenant
                Electrical System                                                       Mechanical System

                                                                           Remote WEB
                                                                           Interface



                                        Electrical                                    BMS
                                         System                                     Mechanical
 Branch                                                                              System         VSD
 Circuit    Tenant     House
Monitoring Services   Services




                                 Generator
                                  System
                                                                                           Water, Air, Gas
                                                        ION Enterprise                       Systems
                                                                                    WAGES
                                                                                    System
                                          UPS
                                         System

                                                              WASTE
                                                             Monitoring

				