TOF ICPMS all (DOC) by nuhman10

VIEWS: 37 PAGES: 26

									                                                               1




ICPMS Bibliographies: Time of Flight ICPMS (TOF-ICPMS)
compiled by C.B. Douthitt
updated 5/2007
isotopems@gmail.com
Journal Articles and Book Chapters
Talks, Posters and Short Courses presented at Conferences

The following document is a comprehensive bibliography of all publications pertinent to TOF-ICP-MS. This
document will be upgraded periodically. If readers have any corrections or additions, please email them to me.
Within each list, publications are ordered from the youngest to the oldest, and within years they are ordered
alphabetically.

* indicates that one or more of the authors was employed by the MS manufacturer; the underlining indicates the
author’s employment status at time of the last update (currently employed vs. formerly employed)

All articles use data from the Leco model Renaissance unless otherwise noted
¶ indicates home made instruments from Prof. Hieftje’s laboratory

Journal Articles and Book Chapters



 Journal Articles. Book Chapters, Theses

                                             2007
Cizdziel J., 2007, Determination of lead in blood by laser ablation ICP-TOF-MS analysis of blood spotted and dried on
          filter paper: a feasibility study. Anal Bioanal Chem. 388, 603-611
Samuel Duwe and Hector Neff,, 2007, Glaze and slip pigment analyses of Pueblo IV period ceramics from east-
          central Arizona using time of flight-laser ablation-inductively coupled plasma-mass spectrometry (TOF-
          LA-ICP-MS) . Journal of Archaeological Science, 34, 403-414
Gustavsson I. and M. Granfors, 2007, Determination of Trace Elements in Steel, nickel-base Alloy and Zircaloy
          Using Time of Flight Inductively Coupled Plasma Mass Spectrometry. Metallurgical Analysis, 27, 8-12
          Chinese (from CEPS)
Shulan Liu, 2007, Study of pre-evaporation and matrix effects on multi-elemental analysis by ICP-TOFMS.. Ph.D.
          Thesis, Queens University, Chemistry
                                             2006
Forsgard N., Nilsson E., Andersson M., and J. Petterson, 2006, Investigation of matrix effects in boron determination
       using organic solvents as modifiers for liquid chromatography coupled to ICP-MS. Journal of Analytical
       Atomic Spectrometry, 211, 305-310 Leco Renaissance

Huang C. and D. Beauchemin, 2006, A simple method based on IC-ICP-MS to determine conditional stability
       constants. . Journal of Analytical Atomic Spectrometry, 211, 317-320 Leco Renaissance
                                                               2




Infante H.G, Van Campenhout K., Blust R., and F.C. Adams, 2006, Anion-exchange high performance liquid
       chromatography hyphenated to inductively coupled plasma-isotope dilution-time-of-flight mass spectrometry
       for speciation analysis of metal complexes with metallothionein isoforms in gibel carp (Carassius auratus
       gibelio) exposed to environmental metal pollution. J. Chromatogr. A, in press.

Liu S. and D. Beauchemin, 2006, The effect of pre-evaporation on ion distributions in inductively coupled plasma
       mass spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy, 61, 157-163 [GBC]

McClenathan D.M., Wetzel W.C., Lorge S.E., and G.M. Hieftje, 2006, Effect of the plasma operating frequency on the
       figures of merit of an inductively coupled plasma time-of-flight mass spectrometer
       J. Anal. At. Spectrom., 21, 160

Sturgeon R.E., Willie S.N. and Z. Mester, 2006, UV/spray chamber for generation of volatile phot -induced products
       having enhanced sample introduction efficiency. JAAS, 21, 263-265 GBC

Wang W., Liu X., Zhao L., Guo D., Tian X., and F. Adams, 2006, Effectiveness of leaded petrol phase-out in Tianjin,
       China based on the aerosol lead concentration and isotope abundance ratio. Science of the Total
       Environment, 364, 175-187

Zhao, G Jerkiewicz, 2006, Electrochemically formed passive layers on titanium — Preparation and biocompatibility
       assessment in Hank's balanced salt solution Can. J. Chem./Rev. can. Chi, 84, 1132-1145


                                             2005
Ludke C., Skole J., Taubner K., and M. Kriews, 2005, Trace metal analysis in arctic aerosols by an inductively
         coupled plasma-time of flight-mass spectrometer combined with an inductively heated vaporizer.
         Spectrochimica Acta B: Atomic Spectroscopy, 60, 1412-1422 [ISAS home made]
McClenathan D.M. and G.M. Hieftje, 2005, Use of rapid gas-flow modulation for improved performance in inductively
         coupled plasma time-of-flight mass spectrometry. J. Anal. At. Spectrom., 20, 1318
Olivo G.R., Chang F. and T.K. Kyser, 2006, Formation of the auriferous and barren North Dipper veins in the Sigma
       Mine Val d’Or, Canada: constrainsts from structural, mineralogical, fluid inclusion, and isotopic data.
       Economic Geology, 101, 607-631
Ramirez-Molina C., Heudi O., Pullen M., and P.S. Marshall, 2005, Study of bradykinin metabolism by rat lung tissue
          membranes and rat kidney brush border membranes by HPLC with inductively coupled plasma - mass
          spectrometry and orthogonal acceleration time-of-flight mass spectrometry. Journal of Peptide Science,
          12, 220-226 GBC
Scadding C.J., Watling R.J. and A.G. Thomas , 2005, The potential of using laser ablation inductively coupled plasma
          time of flight mass spectrometry (LA-ICP-TOF-MS) in the forensic analysis of micro debris. Talanta, 67, 414-
          424 [GBC]
Willie S., Mester Z. and R.E. Sturgeon, 2005, Isotope ratio precision with transient sample introduction using ICP
          orthogonal acceleration time-of-flight mass spectrometry. Journal of Analytical Atomic Spectrometry, 20
          [GBC]
Yang L., Willie S. and R.E. Sturgeon, 2005, Ultra-trace determination of mercury in water by cold-vapor generation
          isotop dilution mass spectrometry. Journal of Analytical Atomic Spectrometry, [GBC]

                                             2004
                                                              3



REVIEW P. B. Armentrout, 2004, Fundamentals of ion-molecule chemistry. Journal of Analytical Atomic
         Spectrometry, 19,
Jitaru P., Goenaga Infante H. and F.C. Adams, 2004, Simultaneous multi-elemental speciation analysis of
         organometallic compounds by solid-phase microextraction and multicapillary gas chromatography
         hyphenated to inductively coupled plasma-time-of-flight-mass spectrometry. Journal of Analytical Atomic
         Spectrometry, 18, X
Campenhout K., Infante H.G., Adams F., and R. Blust, 2004, Induction and bnding of Cd, Cu and Zn to mtallothionein
         in carp (Cyprinus carpio) Using HPLC-ICP-TOFMS. Toxicological Sciences, 80, 276-287
         REVIEW McClenathan D.M., Ray S.J., Wetzel W.C., and G.M. Hieftje, 2004, Plasma source TOFMS,
         Analytical Chemistry, 76, 159A-166A
Moberg M., Nilsson E.M., Homstrom S.J.M., Lundstrom U., Pettersson J., and K.E. Markides, 2004, Fingerprinting
         metal-containing biomolecules after reductive displacmeent of ionr by gallium and subsequent column -
         switched LC-ICP-MS analysis applied on siderophores. Analytical Chemistry, 76, 2618-2622

                                            2003
Arnason J.G. and B.A. Fletcher, 2003, A 40+ year record of Cd, Hg, Pb, and U deposition in sediments of Patroon
        Reservoir, Albany County, NY, USA. Environmental Pollution, 123, 383-391 [Elan DRC]
Abrankó L., Stefánka Z. and P. Fodor, 2003, Possibilities and limits of the simultaneous determination of As, Bi, Ge,
        Sb, Se, and Sn by flow injection–hydride generation–inductively coupled plasma–time-of-flight mass
        spectrometry (FI–HG–ICP–TOFMS). Analytica Chimica Acta, X
REVIEW Balcerzak M., An overview of analytical applications of time of flight -mass spectrometric (TOF-MS)
        analyzers and an inductively coupled plasma-TOF-MS technique. Anal. Sci., 19, 979-1989
Benkhedda K., Dimitrova B., Infante H.G., Ivanova E., and F.C. Adams, 2003, Simultaneous on-line preconcentration
        and determination of Pt, Rh and Pd in urine, serum and road dust by flow inje ction combined with
        inductively coupled plasma time-of-flight mass spectrometry. Journal of Analytical Atomic Spectrometry,
        18, X
Bings N.H. and Z. Stefánka, 2003, Development of a tungsten filament electrothermal vaporizer for inductively
        coupled plasma time-of-flight mass spectrometry and its possibilities for the analysis of human whole blood
        and serum. Journal of Analytical Atomic Spectrometry, 18, X
Bings N.H., Stefánka Z. and S.R. Mallada, 2003, Flow injection electrochemical hydride generation indu ctively
        coupled plasma time-of-flight mass spectrometry for the simultaneous determination of hydride forming
        elements and its application to the analysis of fresh water samples. Analytica Chimica Acta, 478, X
Kozlov B., Saint A. and A. Skroce, 2003, Elemental fractionation in the formation of particulates, as observed by
        simultaneous isotopes measurement using laser ablation ICP-oa-TOFMS Journal of Analytical Atomic
        Spectrometry, 18, X [GBC]
Skrzydlewska E., Balcerzak M. and Frank Vanhaecke, 2003, Determination of chromium, cadmium and lead in food-
        packaging materials by axial inductively coupled plasma time-of-flight mass spectrometry. Analytica
        Chimica Acta, 479, 191-202
Wehmeier S., Ellam R. and J. Feldmann, 2003, Isotope ratio determination of antimon y from the transient signal of
        trimethylstibine by GC-MC-ICP-MS and GC-ICP-TOF-MS. Journal of Analytical Atomic Spectrometry,
        18, 1001- 1007

                                            2002
Benkhedda K., Infante H. and F.C. Adams, 2002, Inductively coupled plasma mass spectrometry for trace analysis
        using flow injection on-line preconcentration and time-of-flight mass spectrometry. trends in analytical
        chemistry, 21, 332-342
Bings N.H., 2002, Direct determination of metals in lubricating oils by laser ablation coupled to inductively coupled
        plasma time-of-flight mass spectrometry. Journal of Analytical Atomic Spectrometry, 17, X
REVIEW Bouyssiere B., Szpunar J and R. Lobinski, 2002, Gas chromatography with inductively coupled plasma mass
                                                               4



          spectrometric detection in speciation analysis. Spectrochimica Acta Part B., 57, 805-828
Ferrarello C.N., Encinar J.R., Centineo G., García Alonso J.I., de la Campa M.R.F., and A. Sanz-Medel, 2002,
          Comparison of three different ICP-MS instruments in the study of cadmium speciation in rabbit liver
          metallothionein-1 using reversed-phase HPLC and post-column isotope dilution analysis , Journal of
          Analytical Atomic Spectrometry, 17, 1024-1029
Goenaga Infante H., Van Campenhout K., Blust R., and F.C. Adams, 2002, Inductively coupled plasma time -of-flight
          mass spectrometry coupled to high-performance liquid chromatography for multi-elemental speciation
          analysis of metalloproteins in carp cytosols. Journal of Analytical Atomic Spectrometry, 17, 79-87
Goenaga Infante H., Van Campenhout K., Schaumlöffel D., Blust R., and F.C. Adams, 2003, Multi-element speciation
          of metalloproteins in fish tissue using size-exclusion chromatography coupled with ICP-isotope dilution-
          time-of-flight-mass spectrometry. The Analyst, X
Hoffmann E., Lüdke C., Skole J., Stephanowitz H., Wollbrandt J., and W. Becker, 2002, New methodical and
          instrumental developments in laser ablation inductively coupled plasma mass spectrometry. Spectrochimica
          Acta Part B: Atomic Spectroscopy, 57, 1535-1545 [ISAS home made instrument]
Leach A.N. and G.M. Hieftje, 2002, Factors affecting the production of fast transient signals in single shot laser
          ablation inductively coupled plasma mass spectrometry. Appl.Spectrosc. 56, 62-69
Leach A.N. and G.M. Hieftje, 2002, Identification of alloys using single shot laser ablation inductively coupled plasma
          time-of-flight mass spectrometry. Journal of Analytical Atomic Spectrometry, 17,
Leenaers J., Van Mol W., Infante H.G., and F. C. Adams, 2002, Gas chromatography-inductively coupled plasma-time-
          of-flight mass spectrometry as a tool for speciation analysis of organomercury compounds in environmental
          and biological samples. of Analytical Atomic Spectrometry, 17,
Peláez MV., Costa-Fernández J.M. and A. Sanz-Medel, 2002, Critical comparison between quadrupole and time-of-
          flight inductively coupled plasma mass spectrometers for isotope ratio measurements in elemental
          speciation. Journal of Analytical Atomic Spectrometry, 17,
REVIEW Thomas R., 2002, Spectroscopy tutorial: a beginner's guide to ICP-MS, Part VIII --- mass analyzers: time-of-
          flight technology. Spectroscopy, 17, 36-41
Westphal C.S., McLean J.A., Acon B.W., Allen L.A., and A. Montaser 2002, Axial inductively coupled plasma time-
          of-flight mass spectrometry using direct liquid sample introduction.           Journal of Analytical Atomic
          Spectrometry, 17,

                                             2001
* Axelsson B-O., Jörnten-Karlsson M., Michelsen P., and F. Abou-Shakra, 2001, The potential of inductively coupled
        plasma mass spectrometry detection for high-performance liquid chromatography combined with accurate
        mass measurement of organic pharmaceutical compounds . Rapid Communications in Mass Spectrometry,
        15, 375-385 [Platform]
Baena J.R., Gallego M., Valcárcel M., Leenaers J., and F. C. Adams, 2001, Comparison of three coupled gas
         chromatographic detectors (MS, MIP-AES, ICP-TOFMS) for organolead speciation analysis. Analytical
         Chemistry, 73, 3927-3934
Barbastea M., Halicz L., Galy A., Medina B., Emteborg H., Adams F.C., and R. Lobinski, 2001, Evaluation of the
        accuracy of the determination of lead isotope ratios in wine by ICP MS using quadrupole, multicollector
        magnetic sector and time-of-flight analyzers. Talanta, 54, 307-317
Benkhedda K., Infante H.G., Ivanova E., and F.C.Adams, 2001, Determination of sub -parts-per-trillion levels of rare
       earth elements in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow
       injection on-line sorption preconcentration in a knotted reactor. Journal of Analytical At omic Spectrometry,
       16, 995-1001
                                                                5



Bleiner D. and D. Günther, 2001, Theoretical description and experimental observation of aerosol transport processes
         in laser ablation inductively coupled plasma mass spectrometry, Journal of Analytical A tomic Spectrometry,
         16, 449-456
Diegor W., 2001, Evaluation of a water-jacketed spray chamber using time-of-flight inductively coupled plasma mass
        spectrometry (TOF-ICP-MS). Journal of Analytical Atomic Spectrometry, 16, 1196 -1201
Evans R.D., Hintelman H. and P.J. Dillon, 2001, Measurement of high precision isotope ratios for mercury from coals
        using transient signals. Journal of Analytical Atomic Spectroscopy, 16, 1064-1069
Feldmann J., Haas K., Naëls L., and S. Wehmeier, 2001, Investigations into biovolatilisation of metal(loids) in the
       environment by using GC-ICP-TOF-MS. pp. 361- 369 in Plasma Source Mass Spectrometry: the New
       Millenium (Selected papers from the 7th Intl Conference on Plasma Source Mass Spectrometry, 9/10-15/2000,
       U. Durham, Durham, UK), editors G. Holland and S.D. Tanner, Royal Society of Chemistry Special
       Publications 267, 428 pp.
Granfors M. and I. Gustavsson, 2001, Determination of trace and ultra-trace elements in wet-digested steel samples
         using inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS). Journal of Analytical
         Atomic Spectrometry, 16, 1439-1441
Guzowski Jr J.P. and G.M.Hieftje, 2001, Characteristics of a rf-only hexapole ion-guide interface for plasma-source
       time-of-flight mass spectrometry. Journal of Analytical Atomic Spectrometry, in press [home made ICPMS]
Haas K., Feldmann J., Wennrich R., and H-J. Stärk, 2001, Species-specific isotope-ratio measurements of volatile tin
         and antimony compounds using capillary GC-ICP-time-of-flight-MS. Fresenius Journal of Analytical
         Chemistry, 370, 587-596.
Heisterkamp M. and F.C. Adams, 2001, Gas chromatography-inductively coupled plasma-time-of-flight mass
         spectrometry for the speciation analysis of organolead compounds in environmental water samples,
         Fresenius J. Anal. Chem., 370, 597-605.
Hieftje G.M., Ray S.J. , Guzowski J.P., Leach A.M., McLenathan D.M., Solyom D.A., Wetzel W.C., and O.A. Gron,
          2001, All the ions all the time: dream or reality?, in Holland G. and S.D. Tanner (eds.), Plasma Source Mass
          Spectrometry - The New Millenium, RSC, Cambridge, 73
Hieftje G.M. , Barnes J.H., Gron O.A., Leach A.M., McClenathan D.M., Ray S.J., Solyom D.A., Wetzel W.C., Denton
          M.B., and D.W. Koppenaal, 2001, Evolution and revolution in instrumentation for plasma -source mass
          spectrometry. Pure and Applied Chemistry, 73, 1579-1588
Infante H.G., Heisterkamp M., Benkhedda K., Van Campenhout K., Blust R., amd F.C. Adams, 2001, ICP-TOF-MS for
         rapid simultaneous multi-element analysis in fast transient signals. Spectra. Anal., 220, 23-31
Infante H.G., Heisterkamp H., van Campenhout K., Tian X., Blust R., and F.C. Adams, 2001, Time-of-flight inductively
         coupled plasma mass spectrometry for ultratrace speciation analysis of organometallic compounds. pp. 369-
         379 in Plasma Source Mass Spectrometry: the New Millenium (Selected papers from the 7th Intl Conference
         on Plasma Source Mass Spectrometry, 9/10-15/2000, U. Durham, Durham, UK), editors G. Holland and S.D.
         Tanner, Royal Society of Chemistry Special Publications 267, 428 pp.
Leach A.M. and G.M. Hieftje, 2001, Standardless semiquantitative analysis of metals using single -shot laser ablation
        inductively coupled plasma time-of-flight mass spectrometry. Analytical Chemistry, 73, 2959-2967
Leach A.M. and G.M. Hieftje, 2001, Use of an ion guide collision cell to improve analytical performance of an
        inductively coupled plasma time-of-flight mass spectrometry. International Journal of Mass Spectrometry,
        212, 49-63
                                                               6



McClenathan D.M., Ray S.J. and G.M. Hieftje, 2001, Novel flow injection strategies for study and control of matrix
       interferences by inductively coupled plasma time-of-flight mass spectrometry. Journal of Analytical Atomic
       Spectrometry, 16, 987-990
Mester Z., Sturgeon R.E., Lam J.W., Maxwell P.S., and L. Péter, 2001, Speciation without chromatography. Part I.
        Determination of tributyltin in aqueous samples by chloride generat ion, headspace solid-phase
        microextraction and inductively coupled plasma time of flight mass spectrometry. Journal of Analytical
        Atomic Spectroscopy, 16, 1313-1316 [GBC]
Ray S.J. and G.M.Hieftje, 2001, Mass analyzers for inductively coupled plasma time-of-flight mass spectrometry.
          Journal of Analytical Atomic Spectrometry, 16, 1206-
Solyom D.A., Gron O.A., Barnes IV J.H., and G.M. Hieftje, 2001, Analytical capabilities of an inductively coupled
        plasma Mattauch-Herzog mass spectrometer. Spectrochimica Acta Part B: Atomic Spectroscopy, 56, 1717-
        1729
Svantesson E., Pettersson J. and K.E. Markides, 2002, The use of inorganic elemental standards in the quantification
        of proteins and biomolecular compounds by inductively coupled plasma spectrometry. Journal of
        Analytical Atomic Spectroscopy, 17, 491-496
Willie S.N. and R.E. Sturgeon, 2001, Determination of transition and rare earth elements in seawater by flow injection
         inductively coupled plasma time-of-flight mass spectrometry. Spectrochimica Acta Part B: Atomic
         Spectroscopy, 56, 1707-1716 [GBC]


                                              2000
* Bandura D.R., Baranov V.I. and S.D. Tanner, 2000, Effect of collisional damping and reactions in a dynamic
        reaction cell on the precision of isotope ratio measurements. Journal of Analytical Atomic Spectrometry,
        15, 921-928 [Elan 6100 DRC]
Benkhedda K., Infante H.G., Ivanova E., and F.C. Adams, 2000, Trace metal analysis of natural waters and biological
       samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow
       injection on-line adsorption preconcentration using a knotted reactor. Journal of Analytical At omic
       Spectroscopy, 15, 1349-,
Bings N., Costa Fernandez J.M., Guzowski J.P., Jr., Leach A.M., and G.M.Hieftje, 2000, Time-of-flight mass
         spectrometry as a tool for speciation analysis. Spectrochimica Acta Part B: Atomic Spectroscopy, 55, 765-
         776.
Bleiner D., Hametner K. and D. Günther, 2000, The optimization of a laser ablation -inductively coupled plasma "time
         of flight" mass spectrometry system for short trans ient signal acquisition. Fresenius Journal of Analytical
         Chemistry, 368, 37-44
Bleiner D., Plotnikov A., Vogt C., Wetzig K., and D. Günther, 2000, Depth profile analysis of various titanium based
         coatings on steel and tungsten carbide using laser ablatio n inductively coupled plasma - "time of flight"
         mass spectrometry. Fresenius Journal of Analytical Chemistry, 368, 221-226
Broekaert J.A.C., 2000, Mass spectrometry with plasma sources at atmospheric pressure - state-of-the-art and some
        developmental trends. Fresenius Journal of Analytical Chemistry, 368, 15-22.
Centineo G., Montes Bayón M., and A. Sanz-Medel, 2000, Flow injection analysis with inductively coupled plasma
        time-of-flight mass spectrometry for the simultaneous determination of elements forming hydrides and its
        application to urine. Journal of Analytical Atomic Spectroscopy, 15, xx,
                                                               7



Costa-Fernández J.M., Bings N.H., Leach A.H., and G.M. Hieftje, 2000, Rapid simultaneous multielemental speciation
        by capillary electrophoresis coupled to inductively coupled plasma time-of-flight mass spectrometry.
        Journal of Analytical Atomic Spectroscopy, 15, 1063-1068
Emteborg H., Tian X., Ostermann M., Berglund M., and F. C. Adams, 2000, Isotope ratio and isotope dilution
        measurements using axial inductively coupled plasma time of flight mass spectrometry. Journal of
        Analytical Atomic Spectroscopy, 15(03),
Guilhaus M., 2000, Essential elements of time-of-flight mass spectrometry in combination with the inductively
         coupled plasma ion source. Spectrochimica Acta Part B: Atomic Spectroscopy, 55, 1511-1525
Ferrarello C.N., Montes Bayón M., Fernández de la Campa R. and A. Sanz-Medel, 2000, Multi-elemental speciation
          studies of trace elements associated with metallothionein-like proteins in mussels by liquid chromatography
          with inductively coupled plasma time-of-flight mass spectrometric detection. Journal of Analytical Atomic
          Spectroscopy, 15 1558-1563
Haas K., Feldmann J., Wennrich R., and , H-J. Staerk, 2001, Species-specific isotope-ratio measurements of volatile tin
         and antimony compounds using capillary GC-ICP-time-of-flight MS. Fresenius’ Journal of Analytical
         Chemistry, 370, 587-596
Leach A.M., Heisterkamp M., Adams F.C., and G.M. Hieftje, 2000, Gas chromatography inductively coupled plasma
        time-of-flight mass spectrometry for the analysis of organometallic compounds. Journal of Analytical
        Atomic Spectroscopy, 15, 151-155.
Leach A.M. and G.M. Hieftje, 2000, Methods for shot-to-shot normalization in laser ablation with an inductively
        coupled plasma time-of-flight mass spectrometer. Journal of Analytical Atomic Spectroscopy, 15, 1121-1124
Mester Z., Sturgeon R.E., Lam J.W., Maxwell P.S., and L. Péter, 2001, Speciation without chromatography. Part I.
        Determination of tributyltin in aqueous samples by chloride generation, headspace solid-phase
        microextraction and inductively coupled plasma time of flight mass spectrometry Journal of Analytical
        Atomic Spectroscopy, 15, 1313-1316 [GBC]
*REVIEW Myers D.P., Ray S.J. and G.M. Hieftje, 2000, Inorganic time-of-flight mass spectrometry. pp. 447-506 in
       Inorganic Mass Spectrometry, eds. Barshick M., Duckworth D. and S. Smith, Marcel Dekker.
       Sturgeon R.E., Lam J.W.H. and A. Saint, 2000, Analytical characteristics of a commercial ICP orthogonal
       acceleration time-of-flight mass spectrometer (ICP-TOFMS). Journal of Analytical Atomic Spectroscopy, 15,
       607-616 [GBC]


                                    1999
Abou Shakra F., 1999, The determination of arsenic in seawater by Platform ICP-HEX-MS. pp. 120-132 in Plasma
         Source Mass Spectrometry New Developments and Applications (Selected papers from the 6th Intl
         Conference on Plasma Source Mass Spectrometry, 9/13-18/98, U. Durham, Durham, UK), editors G. Holland
         and S.D. Tanner, Royal Society of Chemistry Special Publications 241, 299 pp. [Platform]
Cotter R.J., 1999, The new time-of-flight mass spectrometry, Anal. Chem., 71, 445A
         Emteborg, H., Tian, X., and F.C. Adams, 1999, Quality assurance of arsenic, lead, tin and zinc in copper
         alloys using axial inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS). Journal of
         Analytical Atomic Spectroscopy, 14, 1567-1572
Fraser A.W., 1999, The advantage of using time-of-flight inductively coupled plasma mass spectrometry (TOF-ICP-
         MS) for the analysis of microsamples, in Extended Abstracts from the Mini-symposium held in conjunction
         with the International Mineralogical Association (IMA), Commission on Ore Mineralogy (COM) Short
         Course, Pretoria, SA, 9/13-16/1999, editors Reimold and Cloete, 137 pp.
Mahoney P. P., Ray S. J., Li G., and G.M. Hieftje, 1999, Preliminary investigation of electrothermal vaporization sample
                                                              8



         introduction for inductively coupled plasma time-of-flight mass spectrometry. Anal. Chem., 71, 1378-1383
Russo R.E. et al., 1999, Appl. Phys. A 69 (Suppl.), S895-7
Tian X., Emteborg H., and F.C. Adams, 1999, Analytical performance of axial inductively coupled plasma time of flight
         mass spectrometry (ICP-TOFMS) Journal of Analytical Atomic Spectroscopy, 14, 1807-1814
Vanhaecke F., Moens L., Dams R., Allen L., and S. Georgitis, 1999, Evalu ation of the isotope ratio performance of an
         axial time-of-flight ICP mass spectrometer. Analytical Chemistry, 71, 3297-3303.
Vors E. et al., 1999, Appl Phys. A69 (Suppl.) S165-6
Weck R. A., 1999, ICP TOF MS - forward looking and significant for practical use. LaborPraxis, 23, 26, (German)



                                    1998
* Allen L., Georgitis S., Myers D.P., and K. Brushwyler, 1998, Trace element analysis of metals by laser ablation
        inductively coupled plasma time-of-flight mass spectrometry. Phys. Status Solidi A: 167(2), 357.




                                    1997
Hieftje G.M., Myers D.P., Li G., Mahoney P., Burgoyne T.W., Ray S.J., and J. Guzowski, 1997, Toward the next
         generation of atomic mass spectrometers. Journal of Analytical A tomic Spectroscopy, 12, 287-292
Mahoney P., Guzowski J.P., Jr., Ray S.J., and G.M. Hieftje, 1997, Electrospray ionization time-of-flight mass
         spectrometer for elemental analysis. Applied Spectroscopy, 51, 1464-1470
Mahoney P.P.; Ray S.J., Hieftje G.M., and G.M. Li, 1997, Continuum background reduction in orthogonal-acceleration
         time-of-flight mass spectrometry with continuous ion sources. Journal of the American Society of Mass
         Spectrometry, 8, 125-131
Mahoney P.P., Ray S.J. and G.M. Hietfje, 1997, Time-of-flight mass spectrometry for elemental analysis. Applied
         Spectroscopy, 51, 16A-28A.



                                    1996
Hieftje. G.M., 1996, The future of plasma spectrochemical instrumentation. Journal of Analytical Atomic
         Spectroscopy, 11, 613-621.
Mahoney P., Li G. and G.M. Hieftje, 1995, Laser ablation-inductively coupled plasma mass spectrometry with a time-
         of-flight mass analyzer. Journal of Analytical Atomic Spectroscopy, 11, 401-405.

                                    1995
Myers D.P., Li G., Mahoney P.P., and G.M. Hieftje, 1995, An inductively coupled plasma-time-of-flight mass
         spectrometer (ICP-TOFMS) for elemental analysis. Part II. Optimization and characteristics Journal of the
         American Society of Mass Spectrometry, 6, 400-410
Myers D. P.; Mahoney P.P., Li G., and G.M. Hieftje, 1995, Isotope ratios and abundance sensitivity obtained with an
         inductively coupled plasma-time-of-flight mass spectrometer. Journal of the American Society of Mass
         Spectrometry, 6, 920-927.
Myers D.P., Ray S.J. and G.M. Hieftje, 1995, An inductively coupled plasma time-of-flight mass spectrometer for
         elemental analysis. Part III. Analytical performance. Journal of the American Society of Mass
         Spectrometry, 6, 411-420
Yang P., Myers D.P., Li G., and G.M. Hieftje, 1995, Constant-fraction discrimination/boxcar integrator for plasma
         source time-of-flight mass spectrometry. Applied Spectroscopy, 49, 660-664.
                                                              9




                                    1994
Myers D.P., Li G., Yang P., and G.M. Hieftje, 1994, An inductively coupled plasma-time-of-flight mass spectrometer
       (ICP-TOFMS) for elemental analysis. Part I. Optimization and characteristics. Journal of the American
       Society of Mass Spectrometry, 5, 1008-1016

                                    1993
Myers, D. P.and G.M. Hieftje, 1993, Preliminary design considerations and characteristics of an inductively coupled
        plasma-time-of-flight mass spectrometer. Microchemical Journal, 48, 259-277.
                                                                   10




ICPMS Bibliographies: Time of Flight ICPMS (TOF-ICPMS)
compiled by C.B. Douthitt, 8/07

<chuck@isotopems@gmail.com

ndicates that one or more of the authors was employed by the MS manufacturer; the underlining indicates the
author’s employment status at time of the last update (currently employed vs. formerly employed)

All articles use data from the Leco model Renaissance unless otherwise noted
¶ indicates home made instruments from Prof. Hieftje’s laboratory




2.       Talks and Posters given at Conferences
                                       2007
GSA, Denver, 10/07
NEFF, Hector, Some Applications O f La-Tof-Icp-Ms In Archaeological Provenance Studies :

53rd Intl Conference Anal. Sciences and Spectroscopy (ICASS) and MC-ICPMS workshop, Peterborough, 6/24-
27/2007
T anner S., Baranov V., Bandura D., and O. Ornatsky, New reagents and instrument for multiplexed single particle bioassay
           with ICP-MS

CANAS 07, Konstanz, Germany, 3/18-21/2007
Dick et al., Comparative measurements …
Dick et al., O ptimization of a LA-ICP-TO FMS system
Kriews et al., Trace metal analysis
T hamm E., O ptimization criteria of ICP-TO F-MS



2007 European Winter Plasma Conference, Taormina, Italy, 2/19-23/2007
* Dudgeon J.V. et al., The application of laser ablation ICP-oTO F-MS to the analysis of archaeological artifacts
* Saint A. and C. Rivera, The O ptimass ICP-oTO F-MS: the next step in elemental trace analysis


                                       2006
Asia-Pacific Winter Conference on Plasma Spectrochemistry, Thailand, 11/27-12/1/2006
* Harvey T .M., Saint A.F., and E.J. Setiawan, Laser ablation sampling with the O ptimass 9500 ICP -O TO F MS: advantage s
          and selected applications GBC Optimass 9500
* Harvey T .M., Saint A.F., and E.J. Setiawan, Development and application of the O ptimass 9500 ICP -O TO F-MS GBC
          Optimass 9500
* Saint A.F., and W.J. Balsanke, Exploring the benefits of ICP-O TO F (orthogonal time of flight) fMS for a variety of multi -
          e le ment applications GBC Optimass 9500
                                                                       11



* Saint A.F., Dudgeon J.V. and W.J. Balsanek, Exploring the analytical utility of LA-ICPO FMS for he provenancing of
          archaeological materials GBC Optimass 9500
Watling R.J. et al., ICP-MS and crime scene investigation -just how far can we go? GBC Optimass 9500

33rd FACSS, Lake Buena Vista, FL, 9/24-28/2006
Burger S., Riciputi L.R., Bostick D.A., and D.C. Duckworth, Characterization O f Nuclear Materials Using Time -O f-Flight ICP-
           MS GBC Optima 8000
* Balsanek W. and A. Saint, Exploring the Benefits of ICP- oTO F (orthogonal time of flight) MS for a Variety of Multi -
           Ele ment Applications GBC Optimass 9500
* Dudgeon J., Balsanek W., Neff H., and A. Saint, Exploring the An alytical Utility of LA-ICP-TO FMS for the Provenancing of
           Archaeological Materials GBC Optimass 9500
Holcombe J., Removing some analytical limits using ETV-ICP(TO F)MS
?, Exploring the Benefits of ICP- oTO F (orthogonal time of flight) MS for a Variety of Mul ti-Element Applications



Int Congress on Analytical Sciences ICAS-2006, Moscow, Russia, 6/25-30/2006
Dimitrova-Kolvea B., Ivanova E., Benkhedda K., and F. Adams, Determination of trace elements in natural waters by inductively
         coupled plasma time of flight mass spectrometry after flow injection preconcentration in a knotted reactor



34 th International Symposium on Environmental Analytical Chemistry (ISEAC34), Hamburg, Germany 6/4 -8/2006
* Lindemann T ., Hinrichs J., Reipke J. and B. Spence, Application of ICP-MS as a tool for environmental monitoring
Mihucz V.G., Muranszky G., Ovari M., Steffan I., T atar E., Virag I., Zaray G., and M. Zeiner, Determination of platinum in
         human u rine by sector field inductively coupled plasma mass spectrometry (SF-ICPMS)
Muranszky G., Ovari M., Virag I. and G. Zaray, Chemical characterization of 10 fractions of urban aerosol

54th ASMS, Seattle, WA, 5/28-6/1/2006
Baranov V.I., Bandura D.R., T anner S.D., and O.I. Ornatsky, Novel mass spectrometry based flow cytometer [home ma de T OF-
ICPMS]

39th Annual Convention of the German Society for Mass Spectrometry, 20th ICP-MS Users Meeting; 7th
Symposium on Mass Spectrometric Procedure for Trace Element Analysis, Mainz, Germany, 3/5 -8/2006
Dick D., Kriews M., Miller H., Ludke C., Hoffmann E, and J. Skole, Performance of a newly developed ICP-TO F MS for trace
          me tal analysis in envi ronmental samples [ISAS design]
Kriews M., Ludke C., T aubner K. and J. Skole, Trace metal analysis in Arctic aerosols by an inductively coupled plasma -time
          of flight-mass spectrometer combined with an inductively heated vaporizer [ISAS design]

10 th ISMAS Triennial International Symposium on Mass Spectrometry
Balcerzak M., Multi-elemental analysis of packaging materials by ICP-TO FMS

2006 Winter Conference on Plasma Spectrochemistr, Tucson, AZ, 1/8-14/2005
Agarwal Y., Speciation, supercritical fluid extraction of uranium and simultaneous on line determination by inductively coupl ed plasma
           time of flight mass spectrometry
Bartle E. and R.J. Watling, Provenance determination and authentication of oriental ceramics.
Bings N., Kiera A.F. and S.S-Lehr, New developments in plasma source time-of-flight mass spectrometry for elemental analysis.
Kreschollek T .E. and J.A. Holcombe, Multiplexed ET V-ICP (T OF)MS: a fast platform for elemental analysis.
May C., Dehnhardt M., Zilles K., and J.S. Becker, T HE DEVELOPMENT OF LA -ICP-MS FOR T HE PROVENANCE
           EST ABLISHMENT OF GLASS EVIDENCE
Rogers D., Ray S.J., and G.M. Hieftje, A DUAL SOURCE INDUCT IVELY COUPLED PLASMA/ELECT ROSPRAY IO NIZAT ION
           T IME-OF-FLIGHT MASS SPECT ROMET ER FOR RAPID SPECIAT ION AND MET ALLOMIC ANALYSIS
Rowland A.M. and J.A. Holcombe, USE OF ET V-ICP (T OF)MS FOR ISOT OPIC ANALYSIS AND T HERMAL SEPARAT ION OF
           ISOBARS.
Scadding C., Watling R.J. and A. T homas, FORENSIC ANALYSIS OF MICRO CRIME SCENE DEBRIA
T anner M. and D. Gunther, IN T ORCH LASER ABLAT ION ICP -T OFMS.
                                                                    12



Watling R.J., APPLICAT IONS OF LASER ABLAT ION INDUCT IVELY COUPLED PLASMA MASS SPECT ROMET RY (LA -ICP-
         MS) IN CRIME SCENE INVEST IGAT IONS.
Wetzel W., Shelby D. and G.M. Hieftje OVERCOMING ANALYT E-OXIDE INT ERFERENCES IN INDUCT IVELY COUPLED
         PLASMA T IME-OF-FLIGHT MASS SPECT ROMET RY.




                                       2005
GSA, Salt Lake City, 11/15-19/2005
Knott J.R., Wojcicki A.M., Montanez I.P., and H. Neff, Solution and time of flight laser ablation ICP-MS measurement
of minor and trace elements: an example from Death Valley, California [GBC]

32nd FACSS, Quebec City, Quebec, Canada, 10/9-13/2005
Bings N.H. and S. Schmidt -Lehr, New developments in plasma source time-of-flight mass spectrometry for elemental analysis of fast
           transient signals
Holcombe J. and G. Ertas, T he analytical utility of optimized time resolved ET V-ICP(T OF)MS data collection
Liu S. and D. Beauchemin, Effect of methanol and sodium dodecyl-suflate on radial profiles of ion abundance in inductively coupled
           plasma mass spectrometry
Willie S., Mester Z. and R. Sturgeon, Isotope ratio precision with transient sample introduction using ICP -oa-T OFMS

4th International Conf on Instrumental Methods of Analysis: Modern Trends and Applications, Iraklion, Greece,
10/2-6/2006
Jitaru P., and F.C. Adams, Speciation analysis of mercury in ancient Antarctic ice by SPME in combination with
            multicapillary GC hyphenated to ICP-time -of-flight-MS

22nd IGES, Perth, Australia,m 9/19-23/2005
Kyser K., Elemental distributions in minerals and soils by microwave-assisted continuous leach on-line with
inductively        coupled         plasma        time       of        flight       mass        spectrometry

CSI XXXIV, Antwerp, Holland, Sept 4-9, 2005
T. Kreschollek and J.A. Holcombe, Low background rapid sample introduction for ETV-ICP-TOF-MS

CANAS, Freiberg, Germany, 3/6-10/2005
Bings N.HY., Status und Trends der Plasama -Fluzzeit-Massenspekrometrie in der Elementanlaytik zur Detektion
        transienter Signale
Maitusch J., As-Spoezes-Analytik: von der Extraktion bis zur Detektion [ICP-TO FMS]

Pittcon 2005, Orlando, Florida, 2/27-3/42005
Park S.H., Bostick D.A. and D.C. Duckworth, Electrochemically modulated separations performed on -line with ICP
time-of-flight mass spectrometry with separation and preconcentration of plutonium [Optimass 8000]

Trace elements Conference, Hamilton, NZ, 2/17-18/2005
* Saint A.F., Development of ICP TOF from theory to reality [GBC]

European Winter Conference on Plasma Spectroscopy, Budapest, Hungary, 1/30-2/3/2005
Abranko L. and P. Fodor, Investigation of the similarity of ground water samples based on multivariate statistical
evaluation of trace element chemistry data obtained by ICP-TOFMS
Bings N.H. and J. Skole, Characterization of a new orthogonal ICP-TOFMS system [ISAS home made]


                                       2004
                                                               13



Seventh International Conference, International Society for Trace Elemetn Research in Humans (ISTERH),
Bangkok, Thailand, 11/7-12/2004
Muantongchin M., Bakowska E. and J. Vinosky, Determination of the total non-dietary arsenic in urine by
        inductively coupled plasma mass spectrometry (ICP-MS) [Elan DRC]

31st Federation of Analytical Chemistry and Spectroscopy Societies, FACSS 2004, Portland, OR, 10/4-7/2004
Ertas G. and J.A. Holcombe, ETC-ICP-TOFMS: an ideal coupling of sample introduction and detection limit

Nordic Conference on Plasma Spectrochemistry June 6-9, 2004, Loen, Norway
Adams F., Speciation analysis of mercury in polar regions by capillary gas chromatography -inductively coupled
plasma time-of-flight mass spectrometry

17th International Symposium on the Forensic Sciences, Wellington, New Zealand, 3/28-4/2/2004
Bartle E., and R.J. Watling, The potential of TOF-ICP-MS as a provenance enhancement technique for isotope ratio
analysis of artifacts [GBC]

Pittcon 2004, Chicago, IL, 3/7-12/2004
* Allen L.A., Applications of axial time of flight ICP-MS for isotopic ratio analysis of solid materials using laser
ablation sample introduction
Dorn S.B. and G.M. Hieftje, LA-ICP-MS of silicon-based materials. Part 1: metal-halide-doped plastic-clad silica (pcs)
optical fibers. part 2: string-ribbon solar cells
* Kozlov B.N. and A. Saint, Resolution of millisecond events in plasma source using orthogonal time of flight ICP -
MS [GBC]
* Skroce A., McCrum M. and A. Saint, Study of metal ion concentrations in s eawater samples using orthogonal time
of flight ICP-MS [GBC]
* Skroce A., McCrum M. and A. Saint, New methods for the analysis of arsenic, selenium, iron and chromium in
difficult samples using orthogonal time of flight ICP-MS [GBC]

2004 Winter Conference on Plasma Spectrochemistry, Fort Lauderdale, FL, 1/5-10/2004
McClenathan D., Wetzel W.C. and G.M. Hiefje, Use of modulation techniques in inductively coupled plasma time -of-
flight mass spectrometry
Meija J., Beck T.L. and J.A. Caruso, Characterization of novel selenium volatiles utilizing GC-ICP-MS/GC-TOF-MS
and quantum chemistry modeling techniques
Wetzel W., McClenathan D and G.M. Hieftje, Investigation and alleviation of analyte -oxide interferences by
inductively coupled plasma time-of-flight mass spectrometry


                                     2003
GSA, Seattle, WA, 11/2003
Layton-Matthews D., Leybourne M. and J. Peter, A technique for determining selenium isotope ratios in geologic
        materials using a CHG-ICP-DRC-MS, with applications to Se-rich volcanic-hosted massive sulfide
        deposits of the Finlayson Lake District, Yukon [Elan DRC]

Ludke C., Hoffmann E., Skole J., Kriews M., and C. Piel, ETV-ICP=TOF-MS. A new tool for studying size classified
        atmospheric particles [ISAS home made]


         ISMS Conference, Edinburgh, UK
         Liljegren G., Nilsson , Pettersson J., and L. Nyholm, Electrochemically controlled solid -phase extraction
                                                    14



coupled to ICP-TOF MS

FACSS, Fort Lauderdale, FL, 10/19-23/2003
Allen L., Teffera S. and J. O'Kelley, Calibration strategies for direct quantitative elemental analys is of
deposited airborne particles using laser ablation ICP-TOFMS
Duckworth D.C., Park S.H., Bostick D.T., and P. Cable-Dunlap, Advanced nuclear forensic technologies for
uranium and plutonium sampling, separation, and analysis

ARGUS 2003 (Analytical Russian German Ukrainian Symposium) Hamburg, Germany, 8/31-9/05/03
Bings N.H., Status and trends in plasma source time-of-flight mass spectrometry for elemental analysis and
speciation

The 5th International Symposium on Speciation of Elements in Biological, Environmental and Toxicological
Sciences, Almunecar, Spain, 9/13-16/2003
Jitaur P., Infante H.G. and F.C. Adams, Multicapillary gas chromatography coupled to inductively coupled
plasma-time of flight-mass spectrometry for rapid mercury speciation analysis

18. ICP-MS Anwendertreffen, Berlin, Germany, 10/6-9/2003
Infante H.G., Van Campenhout K., Blust R., and F.C. Adams, Isotope dilution analysis with HPLC-ICP-
TOFMS for biomonitoring of metal aquatic pollution
Lüdke C., Hoffmann E., Skole J., and Jörg Wollbrandt, Auf dem Weg zur simultanen Mikroanalyse - erste
Anwendungen eines ICP-TOFMS [ISAS home made]

Mass Spectrometry in Homeland Security Workshop, Knoxville, TN, 9/16-18/2003
Duckworth D., The selectivity of plutonium and uranium studies by EMS-ICP-TOF-MS

ICASS 2003
Beauchemin D., Determination of isotope ratios from transient signals in ICP-MS

GAC/MAC, 5/25-28/2003, Vancouver, BC
Chang F.Y.Y., Olivo G.R. and T.K. Kyser, Characterization of auriferous and barren North Dipper Veins at the
Sigma Mine, Val d'Or, Quebec, based on structural, mineralogical, fluid inclusion and isotope results

Analytical Colloquium on Atom CANAS ’03, Constance, Germany, 3/23-27/2003
Hoffmann E., ICP-TOF-MS-systems-new innovations [ISAS home made]

2003 European Winter Conference on Plasma Spectrochemistry, Garmisch-Partenkirchen, Germany, 1/12-
17/2003
Benkheddda K., Infante H.G., Dimitrova B., Ivanova E., and F. Adams, Determination of platinum group
metals in clinical and environmental samples by flow injection combined with ICP-TOF-MS detection
Carrión M.C., Andrés J.R., Rubi J.A.M., and H. Emteborg, A determination of REE in geological samples by
ICP-TOFMS –A comparison between laser ablation with RVAC and ultrasonic nebulization
Feldmann J and D. Lyon, 2-D-mapping of trace elements in scrapie-infected and non-infected mice brain by
laser ablation ICP-MS
Infante H.G., Cuyckens F., Van Campenhout K., Blust R., ., Claeys M., and F.C. Adams, Characterization of
metal complexes with metallothioneins in the Cyprinus carpio tissue by reversed-phase HPLC with ICP-time-
of-flight-mass spectrometry and electrospray (ES)-mass spectrometry
Jitaru P., Goenaga Infante H. and F.C. Adams, Rapid determination of mercury species in environmental
samples by MCGC-ICP-TOFMS Following in situ ethylation and purge-and-trap injection
* Kozlov B. and A. Saint, Measurement of Isotope ratios with laser ablation ICP-OTOF-MS [GBC]
                                                             15



         * Lehmkaemper H. and L. Allen, Enhanced elemental and isotopic analysis capabilities using ICP-TOFMS
         Lüdke C., Hoffmann E., Skole J., and J. Wollbrandt, A new time of flight mass spectrometer combined with an
         ICP [ISAS home made]
         Park S.H., Van Berkel G.J. and D.C. Duckworth, Evaluation of electrochemically modulated separations
         coupled on-line with time-of-flight ICP-MS
         * Skroce A., Saint A. and M. McCrum, Trace element determination in natural waters using orthogonal time
         of flight ICP-MS [GBC]
         Skrzydlewska E. and M. Balcerzak, The application of ICP-TOF-MS technique to the determination of toxic
         elements in food-packaging materials
         Stefanka Z., Flow injection ICP time-of-flight mass spectrometry coupled to hydraulic high pressure
         nebulizer for the analysis of low volume biological samples




                                    2002
Workshop "Elementspeziation, Mainz, 10/17-18/2002
Boulyga S.F., Pickhardt C. and J.S. Becker, Application of laser ablation collision cell ICP-MS in comparison to
        instrumental neutron activation analysis for determination of trace elements in high-purity graphite
        [Platform]
Boulyga S.F., Pickhardt C., Becker J.S., Buddrus S., Przybylski M., and J.S. Becker, Determination of phosphorus,
        sulphur and iron in proteins using advanced ICP-MS techniques [Platform]

Workshop "Elementspeziation, Mainz, 10/17-18/2002
      Adams F., ICP-TOF-MS coupled with separation methods for elemental speciation

         29th Annual Meeting FACSS, 10/13-17/2002, Providence RI
         * Allen L.A., Elemental and isotopic analysis using ICP-TOFMS
         Wetzel W.C., Myers D.P., Leach A.M., and G.M. Hietfje, Design considerations for dual-reflectron time-of-
         flight mass spectrometer

         2nd Franco-Spanish Workshop on Bio-Inorganic Analytical Chemistry, Pau, France, 9/26-28/2002
         Goenaga Infante H., Multi-element speciation of metalloproteins in fish tissue using size-exclusion
         chromatography coupled "on-line" with ICP-isotope dilution-time-of-flight-mass spectrometry

         8th International Conference on Plasma Source Mass Spectrometry, University of Durham, UK, 9/8 -
         13/2002
         Infante H.G., Van Campenhout K., Schaumlöffel D., Blust R., and F.C. Adams, Multi-element speciation of
         metallo-proteins in fish tissue using size- exclusion chromatography coupled on-line with ICP-Isotope
         dilution time of flight mass spectrometry.
         Wehmeier S. and J. Feldmann, GC coupled to MC and TOF-ICP-MS for the determination of isotope ratios
         of volatile organometallic species

         CSI XXXIII, Granada, Spain, 9/7-12/2003
         Andres J.R., Emteborg H., Rubi J.A.M., and M. Carrion, Parameter optimization and application of isotope
         ratio measurements in geological samples using LA-ICP-TOFMS

         6th International Nickel Conference, Murmansk, Russia, 9/1-6/2002
         Kindness A., Sekaran C.N., and J. Feldmann, 2-D mapping of trace elements in soft tissues by laser
         ablation-ICP-TOF-MS
                                                    16




CSI XXXIII Presymposium on Sample Introduction in Atomic Spectrometry: New Strategies, Zaragoa,
Spain, 9/3-5/2003
Rodriquez P.F., Pelaez M.V., Fernandez J.M.C., Marchante-Gayon J.M., and A. Sanz-Medel, Evaluation of
the performance of quadrupole and time-of-flight inductively coupled plasma mass spectrometers in
combination with electrothermal vaporization sample introduction for multiisotope determination

16th IMSC Edinburgh, Scotland, 8/31-9/5/2003
Liljegren G., Nilsson E., Pettersson J., and L. Nyholm, Electrochemically controlled solid-phase extraction
coupled to ICP-MS

18th NASTEC, Naantali, Finland, 8/18-21/2002
Granfors M. and I. Gustavsson, Analysis of steel and metals using laser ablation inductively coupled
plasma time of flight mass spectrometry (LA-ICP-TOFMS)

11th Biennial National Atomic Spectroscopy Symposium, Loughborough University, UK, 7/8 -10/2002
Wehmeier S. and J. Feldmann, Biovolatilization of metal(loids) in anaerobic digestion of sewage sludge; an
application of CT-CF-ICP-TOF-MS

Nordic Plasma 2002, Nordic Conference on Plasma Spectrochemistry, Loen, Norway, 6/2 -5/2002
Adams F., Flow injection analysis combined with ICP time-of-flight mass spectrometry
Saint A., Skroce A. and M. McCrum, A new concept in orthogonal time of flight ICP-MS [GBC]

50th ICASS (International Conference on Analytical Sciences and Spectroscopy) and 4th EnviroAnalysis
Conference, Toronto, Canada, 5/27-31/2002
* Allen L., Teffera S. and J. O’Kelly, Elemental analysis of airborne particulate matter using ICP-TOFMS
with solution and direct solid sample introduction
Benkhedda K., Ivanova E., Goenaga Infante H., and F.C. Adams, Flow injection and time of flight inductively
coupled plasma mass spectrometry for environmental multi-element trace analysis

International Workshop on Progress in Analytical Chemistry in the Steel and Metal Industries,
Luxembourg, 5/14-16/2002
Grantor M. and I. Gustavsson, Analysis of steel and metals using laser ablation inductively coupled plasma
time of flight mass spectrometry (LA-ICP-TOFMS)

Pittcon 2002, New Orleans, LA, 3/17-22/2002
Adams F.C., Benkhedda K. and H.G. Infante, A powerful marriage: flow injection and ICP TOFMS
Guenther D., Bleiner D. and M. Guiloong, Insights in elemental composition of laser-induced aerosol
formation using ICP-TOFMS
Hieftje G.M., The advantages of speed and simultaneous extraction in PS -TOFMS

Seventh International Symposium on Hyphenated Techniques in Chromatography and Hyphenated
Chromatographic Analyzers, Brugge, Belgium 2/6-8/2002
Adams F. and H. Goenaga Infante, ICP-time-of-flight mass spectrometry: a fast transient detector for
environmental analysis
Goenaga Infante H., Van Campenhout K., Blust R., and F.C. Adams, Capabilities of high performance liquid
chromatography coupled to axial inductively coupled plasma time-of-flight mass spectrometry for multi-
elemental speciation studies of ultra-trace metals associated with metallothioneins in common carp
cytosols.
                                                            17



        Winter Plasma Conference on Plasma Spectrochemistry, Scottsdale, AZ, 1/4-8/02
        * Allen L., Applications of an inductively coupled plasma time of flight mass spectrometer
        Bings N.H., Using laser ablation time-of-flight mass spectrometry for the characterization of ancient
        gypsum objects
        Hieftje G.M., New knowledge and instrumentation for plasma-source mass spectrometry [home made]
        Infante H.G., van Campenhout K., Blust R., and F.C. Adams, Complementary high performance liquid
        chromatographic separations coupled with axial inductively coupled plasma time-of-flight mass
        spectrometry (ICP-TOFMS) for multi-element speciation of metallothionein isoforms in carp
        Longerich H., and W. Diegor, Evaluation of a water jacketed spray chamber using a time of flight-
        inductively coupled plasma-mass spectrometer (TOF-ICP-MS)
        McClenathan D.M., Wetzel W.C. and G.M. Hieftje, Effect of plasma operating frequency on the figures of
        merit of an inductively coupled plasma time-of-flight mass spectrometer
        SHORT COURSES, 2002 Winter Conference
        Time-of-Flight Mass Spectrometry for Elemental Analysis, Hieftje G.M.

Theory and operation of reaction cells for ICP-MS, Tanner S., Baranov V. and D. Bandura,

                                   2001
SPECS, Pittsburgh, PA, 11/12/2001
       Hieftje G.M., Evolution and revolution in instrumentation for plasma-source mass spectrometry

        Indiana University Chemistry Department Seminars, Bloomington, IN 10/23/01
        Wetzel W.C., Advances in elemental analysis by plasma-source time-of-flight mass spectrometry

        FACSS 2001, 28th Annual Conference of the Federation of Analytical Chemistry and Spectroscopy
        Societies, Detroit, MI USA 10/05-12/2001
        * Allen L. and R. Wolf, Elemental analysis of automatic glass for forensic comparison by LA -ICP-TOFMS
        Duan Y., New features in plasma source spectroscopy [home made]

        International Conference Instrumental Methods of Analysis Modern Trends and Applications, Ioannina,
        Greece, 9/5-8/2001
        Adams F., ICP time-of-flight mass spectrometry: a fast transient detector for environmental analysis
        Ivanova E., Benkjedda K., Goenaga Infante H., and F. Adams, The knotted reactor for on -line trace element
        preconcentration with ET-AAS and ICP-time-of-flight Mass Spectrometry

        18th Trent Meeting , 8/2001
        Shi Y., Precise measurement of lead isotope ratios in environmental samples by ICP-MS: A comparison
        between a quadrupole instrument and a time-of-flight ones

        Analysdargarna, Stockholm, Sweden, 6/11-14/2001
        Emteborg H., Inductively coupled plasma time of flight mass spectrometer (ICP-TOFMS) and laser ablation
        Granfors M., Analysis of steel using laser ablation Inductively coupled plasma time of flight mass
        spectrometer (ICP-TOFMS)

        49th ASMS, American Society of Mass Spectrometry, Chicago, IL, 5/27-31/2001
        McClenathan D.M. and G.M. Hieftje, Flow injection analysis as a means of detecting and overcoming
        interferences in inductively coupled plasma time-of-flight mass spectrometry
                                                     18



2001 GAC-MAC, St. John’s, NF, Canada, 5/27-30/2001
Guenther D. and C. Heinrich, Laser ablation-inductively coupled plasma-mass spectrometry: strategies to
analyze the elemental composition of individual micro-inclusions

2nd International Conference on Trace Element Speciation in Biomedical, Nutritional and Environmental
Sciences, Munich, Germany, 5/7-10/2001
Feldmann J., Haas K. and S. Wehmeyer, Determination of the isotope ratios of metal(loid)s in their volatile
species using GC-ICP-QMS and GC-ICP-TOFMS

SETAC Europe 11th Annual Meeting, Society of Environmental Toxicology and Chemistry Madrid, Spain
5/6-10/200
Van Campenhout K., Goenaga Infante H., Tian X., Adams F., and R. Blust, HPLC-ICP TOF MS for metal
speciation on metallothioneins in carp cytosols

2001 Tsukuba Seminar,
Hieftje G., Time-of-flight mass spectrometry in elemental analysis

Seminar Series Univ. of Antwerpen, Antwerp, Belgium, 3/13/2001
Bleiner D. and D. Günther, Sampling strategies of natural fluid inclusions using laser ablation -ICPTOFMS

CANAS ’01 (Colloquium Analytische Atomspektroskopie) Freiberg/Sachsen 3/11-15/2001
Bings N.H., Die Bestimmung von anorganischen Haupt-, Neben, und Spurenbestandteilen von Neu- uand
Gebrauchtölen mittels der Laser Ablation-ICP-flugzeitmassenspektrometrie
Hieftje G., New instrumentation and capabilities for plasma-source mass spectrometry
Mattusch J and R. Wennrich, Speziationsanalyse durch Kopplung von Flüssigchromatogrpahie mit ICP=-
TOFMS Detektion


52nd Pittcon, New Orleans, LA 3/04-09/2001
* McCrum M., Saint A. and S.D. Dowling, Deconvolution of isobaric interferences by simultaneous ICP
time-of-flight MS [GBC]
* McCrum M. and A. Saint, Factors influencing the optimiation of ICP time-of-flight MS for laser ablation
sampling [GBC]

The Opening Seminar, Trent University Institute for Mass Spectrometry, ON, 2/16/2001
McDowell D.C., Inductively-coupled plasma/time-of-flight mass spectrometry (ICP/TOFMS): Method
development for the determination of organo-lead, mercury, and tin compounds using capillary gas
chromatography (GC)

European Winter Conference on Plasma Spectrochemistry, Lillehammer, Norway, 2/4-8/2001
Bings N.H., ICP-TOF-MS for isotope ratio measurements and fast transient signals generated by laser
ablation
Bings N.H., Determination of inorganic major, minor and trace elements in oils by laser alblation ICP-TOFMS
Evans R.D., Hintelmann H. and P.J. Dillon, High precision isotope ratios on transient signals -is it possible?
Feldmann J., Haas K. and S. Wehmeier, Volatile metal(loid) species generated in municipal waste deposits
using GC-ICP-QMS and GC-ICP-TOFMS: How stable are these compounds during analysis? [Renaissance
Günther D. and D. Bleiner, Studies on the ablation cell and transfer tube efficiency with and without arc -
discharge in LA-ICP-MS
Hieftje G.M., McClenathan D. and S. Ray, Novel strategies for flow-injection methods by means of ICP-
TOFMS.
                                                              19



         Infante H.G., Tian X., van Campenhout K., Blust R. and F.C. Adams, Characterization of metal-binding
         proteins in carp cytosols using high performance liquid chromatography coupled to axial inductively
         coupled plasma time of flight mass spectrometry (ICP-TOFMS)
         * Nitschke F.R., Falter R., Maibusch R., and R.D. Wilken, Is it possible to observe species specific
         transformation processes of mercury species during microcosm experiments?




                                    2000
2nd European Academy of Forensic Sciences Meeting, Cracow, Poland, 9/12-16/2000
Watling R.J., The application of time of flight LA-ICP-MS for the analysis of scene of crime debris

Sixth Rio Symposium on Atomic Spectrometry, Concepción-Pucón/Chile, 12/3-9/2000
Hieftje G.M., Recent advances in plasma-source TOFMS
Sturgeon R., Some applications of ICP-time-of-flight mass spectrometry [GBC]

Seminar Series, ETH Zurich, Switzerland, 11/30/2000
        Bleiner D. and D. Günther, Untersuchungen über die Signalstruktur in laser ablation -ICPMS

2 nd Aegean Analytical Chemistry Days International Training Workshop
        11/1-4/2000
Adams F., Time of flight inductively coupled plasma mass spectrometry and applications in environmental analysis

17th Trent Meeting , 10/2000
McDowell D., Determination of organometals using multicapillary GC coupled to ICP-TOF-MS

7th International Conference on Plasma Source Mass Spectrometry
(Durham Conference), Durham, UK, 9/10-15/2000
Bradford M., Svantesson E., Andersson M., Pettersson J., and K. Markides, Calibration methods and internal
          standards in time-of-flight ICP-MS: a preliminary investigation
de la Campa F., Ferrarello C.N. and A. Sanz-Medel, A comparison between quadrupole, double focussing and time of
          flight as detectors in the speciation of trace metals bound to metallothioneins
Feldmann J., Haas K., Naels L., and R. Wennrich, Investigations into biovolatilization of metal(loid)s in the
          environment by using GC-ICP-QMS and GC-ICP-TOF-MS
Infante H.G., Benkhedda K., Ivanova E., and F.C. Adams, Trace metal analysis of environmental and biological
          samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOF-MS) with flow
          injection on-line preconcentration using a knotted reactor and ultrasonic nebulization
* Maibusch R., The application of time of flight (TOF) ICP-MS to the analysis of transient signals
Tian X., Infante H.G., Emteborg H., and F.C. Adams, Inductively coupled plasma time-of-flight spectrometry (ICP-
          TOF-MS) for isotope ratio measurement

FACSS 2000, 27th Annual Conference of the Federation of Analytical
    Chemistry and Spectroscopy Societies, Nashville, TN, USA 9/24-
    29/2000
         * Allen L. and J. Fucsko, Elemental and isotopic analysis of packaging materials by ICP-TOF-MS
         Duan Y., Su Y. and Z. Jin, New developments in plasma source time-of-flight mass spectrometry [home
         made]
                                                     20



Guzowski J., Leach A.M. and G.M. Hieftje, Use of ion guides to improve the performance of inductigely
coupled plasma time-of-flight mass spectrometry [home made]
Leach A.M. and G.M. Hieftje, Getting the correct answers: semiquantitativ e analysis using single shot laser
ablation inductively coupled plasma time-of-flight mass spectrometry [home made]
McClenathan D.M., Ray S.M., Leach A.M., and G. M. Hieftje, Investigation of interferences in an
inductively coupled plasma time-of-flight mass spectrometer by flow injection [home made]
* Westphal C.S., McLean J.A., Acon B.W., Allen L.A., and A. Montaser, Inductively coupled plasma axial
time-of-flight mass spectrometry with a direct injection high efficiency nebulizer

4th Euroconference on Environmental Analytical Chemistry,
Visegrad, Hungary, 9/14-19/2000
Adams F., Heisterkamp M. and H Goenaga-Infante, ICP time-of-flight mass spectrometry as a fast transient
signal detector for environmental analysis
Benkhedda K., Goenaga Infante H., Ivanova E., and F.C.Adams, Trace metal analysis of natural water
samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow
injection on-line adsorption preconcentration using a knotted reactor
Bings N.H., Costa-Fernandez J.M, Leach A.M., and G.M. Hieftje, Time-of-flight mass spectrometery for
elemental speciation analysis [home made]
Leenaers J., Heisterkamp M., Slaets S., and F.C. Adams, Application of axial inductively coupled plasma
time-of-flight mass spectrometry in combination with capillary gas chromatography as a detection sysetem
for the speciation analysis of organmercury compounds in environmental samples

15th International Mass Spectrometry, Barcelona, Spain, 9/3-8/2000
Hieftje G.M., New instrumentation and capabilities in plasma-source mass spectrometry

5. Symposium Massenspektrometrische Verfahren der
Elementspurenanalyse zusammen mit dem 16. ICP-MS
Anwendertreffen, (5th Symposium Mass Spectrometric Techniques of
Trace Analysis" together with the"16th ICP-MS User Meeting") 9/18–
21/2000 Juelich, Germany
Adams F. and M. Heisterkamp, ICP TOF MS for elemental and speciation analysis
Bleiner D. and D. Guenther, Comparison of laser-induced aerosol transport efficiency of various ablation
cells in LA-ICP-TOFMS
* Falter R., Maibush R. and H. Lehmk(mper, Wo findet die TOF (time of flight) ICP-Massenspektrometrie
ideale Anwendung?
* Hass, K., St(rk H.-J., Wennrich R., Feldmann J., and R. Maibusch, Analyse von fl(chtigen
Organometall(oid)-Verbindungen in Umweltgasen mitttels CT-GC-ICP-TOF/MS

4th International Conference on the Analysis of Geological and
Environmental Materials (Geoanalysis 2000, Port ( Mousson, Lorraine, France, ) 8/30-
9/1, 2000,
* Falter R., Maibusch R. and H. Lehmkämper, A time of flight ICP-MS used for fast transient analysis.
* Kruger F.J., Allan L. and A. Fraser, Combined electron probe and LA -ICP-TOF-MS analysis of major and
trace elements in garnet, apatite and zircon
Motelica-Heino M., Krupp E., Pecheyran C., and O. F.X. Donard, Laser sources coupled to different ICP-MS
detectors (Q, TOF, MC) for environmental isotopic information

NASTEC 2000, Elements and their Compounds, Loen, Norway 8/18-23/2000
                                                     21



Emteborg H., Time of flight mass spectrometry in theory and practice

46th ICASS August 13-16, 2000
McDowell D. and H. Hintelmann, Method development for the analysis of organo -lead, mercury and tin
compounds using multicapillary GC with TOF ICP-MS,

31st International Geological Congress, Rio de Janeiro, Brazil, 8/6-
17/2000
Heinrich C.A. and D. Guenther, Microanalysis of minerals, fluid and melt inclusions by excimer laser-
abklation ICP mass spectrometry

10th Biennial National Atomic Spectroscopy Symposium (BNASS),
7/17-20/2000, Sheffield Hallam University, United Kingdom
Centineo G., Bayón M.M. and A. Sanz-Medel, Simultaneous determation of As, Bi, Ge, Hg, Sb, Se and Sn in
urine by flow injection-hydride generation-inductively coupled plasma-time-of-flight mass spectrometry (FI-
HG-ICP-TOFMS)
* Fucsko J., Allen L. and D.L. James, The use of time-of-flight ICP-MS for the analysis of transient signals
from various applications.

5th European Workshop on Laser-Ablation ICP-MS, ETH Zurich,
6/26-27/2000
REVIEW Donard O., Laser sources coupled to different ICP/MS detectors (Q, TOF, MC) for environmental
isotopic information

3rd Mediterranean Basin Conference on Analytical Chemistry, 6/4-
9/2000, Antalya, Turkey,
Sanz-Medel A., New tools for trace element speciation: capillary electrophoresis coupled to less common
ICP-MS (DF and TOF-ICP-MS)

22. Spektrometertagung: Year 2000: Turn of the Century in Atomic
Spectrometry and Element Analysis - Past, Present and Future,
Interlaken, Switzerland, 6/5-8/2000,
Hoffmann E., ICP-time of flight MS: advantages and limitations [home made]

3rd Biennial International Conference on Monitoring and
Measurements of the Environment: EnviroAnalysis 2000
Adams F., Tian X. and M. Heisterdamp, ICP time-of-flight mass spectrometry for elemental and speciation
analysis of environmental samples

Pittcon, 3/12-17/2000, New Orleans, LA
* Allen L., Analytical advantages of time-of-flight ICP-MS with transient sample introduction.
* Fucsko J., Cool plasma performance and simultaneous advantages of axial TOF-ICP-MS.
Hieftje G.M., TOFMS for elemental analysis -the wave of the future.
* Moore L., Factors influencing the optimization of iCP-TOFMS for laser ablation scanning. [GBC]
* Moore L., The measurement of isotope ratios to high precision using a ICP time-of-flight MS [GBC]

Sjunde Nordiska Anv(ndarm(tet I ICP-Teknikken och ICP-MS, Stora
Br(nnbo Kursgard, Sigtuna, Sweden, 2/2-3/2000
                                                               22



         * Emteborg H., Axial ICP time of flight mass spectrometry-in theory and in practice
         Pettersson J., Grundl(ggande begrepp inom ICP-MS

         Winter Plasma Conference, 1/10-15/2000, Fort Lauderdale, FL, USA
         Bings N.H., Costa-Fernandez J.M., Leach A.M. and G.M. Hieftje, Elemental speciation by capillary
         electrophoresis-inductively coupled plasma time-of-flight mass spectrometry.
         Bleiner D., Hametner K. and D. Guenther, Laser ablation-ICP-TOF-MS-do we really get more information?
         Emteborg H., Tian X. and F.C. Adams, Isotope ratio measurements by inductively coupled plasma time of
         flight mass spectrometry-accuracy, precision and application
         Evans R.D., Time of flight ICP-MS for measurement of fast transient signals from capillary electrophoresis
         * Fucsko J, Allen L, and S. Georgitis, Identification of contamination in plastic materials using laser ablation
         TOF-ICP-MS)
         Leach A.M., Costa-Fernandez J.M., Bings N.H., and G.M. Hieftje, Methods for shot-to-shot normaliziation in
         laser ablation using an inductively coupled plasma time-of-flight mass spectrometer.
         Tian X., Emteborg H., Barbaste M., Lobinski R., Galy A.J.B., and F.C. Adams, Accuracy and precision for
         isotope ratio measurements of lead isotope ratios in wines by inductively coupled plasma time of flight mass
         spectrometry
         Tye D., Caughlin B. and H.P. Longerich, Analysis of geological samples using time of flight -inductively
         coupled plasma-mass spectrometry (TOF-ICP-MS)
         * Venable J., Holcombe J.A., Allen L., Fucsko J., and S. Georgitis, Fundamentals and applications of
         electrothermal vaporization using a time of flight inductively coupled plasma mass spectrometer
         Watling J., The application of time-of-flight LA-ICP-MS to the analysis and interpretation of microscopic
         scene of crime evidence




                                     1999
ISAS Annual Report, 1999
Feldmann I., Jakubowski N. and D. Stuewer, Application of a hexapole collision and reaction cell in ICP-M:
       assessment of a new tool [Platform]

Bleiner D. and D. Günther, Laser ablation ICP - time of flight-MS: which advantages for fluid inclusion analysis

8th Indian Society for Mass Spectrometry (ISMAS) Symposium on Mass
Spectrometry, Mumbai, India, 12/7 -9/99
Guilhaus M., Selby D. and V. Mynski, Orthogonal acceleration time-of-flight mass spectrometry at UNSW and
beyond [GBC]

38th Annual Eastern Analytical Symposium, Somerset, NJ, 11/14-19/1999
Hieftje G.M., Time-of-flight mass spectroscopy: now for elemental analysis

8th Beijing Conference and Exhibition on Instrumental Analysis, 10/ 25-
28/99, Beijing, PRC
* Hieftje G.M., Ray S.J. Guzowski J.P., Leach A.M., Bings N.H., and J.M. Costa-Fernandez, A new generation of
instrumentation and capabilities for atomic mass spectrometry

26th Annual Conference of the Federation of Analytical Chemistry and
Spectroscopy Societies (FACSS), 10/99, Vancouver, BC Canada
                                                                23



Adams F., Emteborg H., Tian X., and M. Heisterkamp, Inductively coupled plasma time -of-flight mass spectrometry
for elemental and ultra-trace speciation analysis
* Allen L., Enhanced instrumentation through multipurpose collaboration
* Allen L.A., Fucsko J. and S. Georgitis, Direct multielement micro -characterization of solid sample by laser ablation
time of flight ICP/MS
Caughlin B. and H.P. Longrich, Analysis of geological samples using time of flight-inductively coupled plasma-mass
spectrometry (TOF-ICP-MS)
Emteborg H., Tian, X., Berglund M., and F. Adams, Accuracy and precision of isotope ratio measurrement by
inductively coupled plasma time of flight mass spectrometry, ICP-TOF-MS
Guzowski J.P., Jr., Leach A.M., Costa-Fernandez J., Bailey R., and G. M. Hieftje, Use of a collision cell to improve the
performance of plasma-source TOFMS
Hieftje G., Buzowski J.P. Jr, Leach A.M., and J. Costa-Fernandez, Use of a collision cell to improve the performance of
plasma-source TOFMS.
Moore L. and G. Bercowy, ICP time-of-flight MS for bulk and feature analysis of geochemical samples with laser
ablation [GBC]
Moore L., Kremser D. and S. Shuttleworth, Laser ablation and ICP-TOF-MS: calibration and analysis of geological
materials [GBC]
Ray S., McClenathan D.M., Leach A.M., and G. M. Hieftje, Factors influencing measurement precision in plasma -
source time-of-flight mass spectrometry
Ray S., McClenathan D.M., Leach A.M., and G. M. Hieftje, Investigation o f matrix intterferences in an inductively-
coupled plasma time-of-flight mass analyzer
Sturgeon R. and J. Lam, Initial experiences with commercial ICP-time-of-flight mass spectrometry [GBC]


International Conference on Instrumental Methods of Analysis Modern
Trends and Applicaions IMA ’99, 9/19-22/99, Chalkidiki, Greeece
Adams F.C., Emteborg H., Heisterkamp M., and X. Tian, Inductively coupled plasma time -of-flight mass spectrometry
for elemental and ultra-trace speciation analysis.
Xian T., Emteborg H., Berglund M., and F.C. Adams, The application of inductively coupled plasma time -of-flight
mass spectrometry (ICP-TOF-MS) for elemental analysis

German ICPMS user meeting, in Dresden, Germany, 9/19-21/1999
Bleiner D., Hattendorf B., Hametner K., and D. Günther, Wieviele Isotope muss man messen, damit sich ein ICP-
TOFMS lohnt?
Plotnikov A., Bleiner D., Vogt C., and D. Günther, Depth profile analysis of various titanium coatings using LA -ICP-
TOFMS

Modern Approaches to Ore and Environmental Mineralogy, International
Mineralogical Association (IMA), Commission on Ore Mineralogy (COM)
Short Course. Pretoria, South Africa, 9/13-16/1999
Fraser A.W., The advantage of using time-of-flight inductively coupled plasma mass spectrometry (TOF-ICP-MS) for
the analysis of microsamples

5th International Conference on Laser Ablation COLA 99, Gottingen,
Germany, 6/19-23/99
* Falter R., Weck R., Georgitis S., Allen L., and J. Fucsko, A time of flight ICP-MS used for fast transient signals.

Werkgroep Atoomspectrometrie, Nieuwegein, Holland, 5/28/99
                                                               24



Vanhaecke F.,Welke voordelen biedt de time-of-flight (TOF) massaspectrometer in ICP-MS apparatuur?

10th International Symposium on Trace Elements in Man and Animal,
TEMA 10, Evian, France, 5/2-7/99
Emteborg H., Tian X. and F.C. Adams, Inductively coupled plasma time of flight mass spectrometry for trace element
and speciation analysis.

Etat de l’art en spectrometrie de masse, Groupement analytique Elf
Journee thematique, Elf Atomchem CRRA, 5/1/1999
* ?., Implications for time-of-flight mass spectrometry in GC/MS and ICP/MS

Colloquium Analytische Atomspektroskopie (CANAS '99), Konstanz,
Germany, 3/14-19/1999.
* Weck R., Georgitis S., Allen L., and J. Fucsko, Analysis of fast transient signals by time of flight ICP-MS

17th ANZMS Conference, Thredbo, Australia, 2/1 -4/99
* Davenport C. and L. Moore, Development and application of an ICP orthogonal acceleration time -of-flight MS
[GBC]
Guilhaus M., Inductively coupled plasma time of flight mass spectrometry [GBC]
* Stutchbury G., Allen L., Fucsko J., and S. Georgitis, Advantages in elemental analysis using an axial time of flight
inductively coupled plasma mass spectrometer

8th International Colloquium on          Solid                                 Sampling           with      Atomic
Spectrometry, Budapest, Hungary, 9/1 -5/98
* Fucsko J., Allen L. and S. Georgitis, The unique capabilities of TOF-ICP-MS with microsampling for solid material
analysis

10th International Symposium on Trace Elements in Man and Animal
(TEMA 10), Evian, France, May 2-7, 1999
Emteborg H., Inductively coupled plas ma time of flight spectrometry for trace element- and speciatin analysis

CANAS ’99, Colloquium Anal. Atomspectroskopie 3/14-19/99, Konstanz
Germany
* Weck R., Georgitis S., Allen L., and J. Fucsko, Analysis of fast transient signals by time of flight ICP-MS

15th Symposium of                      Analytical          Chemistry           in     Australia,         7/4-9/99,
Melbourne, Australia
* Stuchbury G., Elemental analysis using ICP - Time of Flight (TOF) MS

                                              1998
22. konference Mikroelementy, Rez u Prahy, 1998.
Cernohorsky T., TOF - ICP - MS nove moznosti v prvkove analyze

4. Symposium Massenspektrometrische Verfahren der Elementspurenanalyse, Mainz,
Germany 9/28–10/1/1998
Hoffmann E., Lüdke C., Wollbrandt J., and M. Rossberg, Ein neues Flugzeitmassenspektrometer für die ICP-MS
                                                               25



[home made]

1998 Winter Conference on Plasma Spectrochemistry, Scottsdale, AZ, 1/5-10/98
* Georgitis S., Myers D. and K. Brushwyler, Calibration strategies for axial TOF-ICP-MS

                                              1997

The 24th Annual Conference of the Federation of Analytical Chemistry and Spectroscopy
      Societies. 10/26-30/97, Providence, Rhode Island FACSS ’97
Allen L., Brushwyler K., Myers D., and S. Georgitis, Expanded capabilities for laser ablation solid sampling via ICP-
         TOFMS; fast transient signals
Bandura D., Davenport C. and R. Peile, Simultaneous multielement analysis by ICP-TOFMS [GBC]
Georgitis S., Brushwyler K., Myers D., and L. Allen, ICP-TOFMS with flow injection: Simultaneous mutielement
         analysis of transient signals
Hieftje G.M., Theoretical and experimental description of an on -axis energy discrimination time-of-flight mass
         spectrometer for ICP-MS
Myers D., Elemental analysis with ICP/TOFMS

XXX Colloquium Spectroscopicum Internationale, Melbourne, Australia, 9/21-25/1997
         * Bandura D. and R. Peile [GBC]



                                              1996

Federation of Analytical Chemistry and Spectroscopy Societies XXIII, 9/29-10/4/96, Kansas
      City, MO
Ray S.J., Myers D.P., Li G., Mahoney P.P., and G.M. Hietje, A novel on -axis time-of-flight mass analyzer for plasma-
         source mass spectrometry.\
44th ASMS Conference on Mass Spectrometry and Allied Topics, 5/12-16, Portland, OR
Hieftje G.M., Li G., Mahoney P., Myers D., and S. Ray, A second generation inductively coupled plasma -time-of-flight
          mass spectrometer.
211th ACS National Meeting, New Orleans, LA, 3/24-28/1996
Mahoney P.P.; Ray S.J.; Myers D.P., Li G., Yang P., and G.M. Hieftje, A plasma-source time-of-flight mass
      spectrometer for elemental analysis.



                                              1994
21st Annual Conference of the Federation of Analytical Chemistry and Spectroscopy Societies
(FACSS), 10/2-7/94, St. Louis, MO
Mahoney P.P., Myers D.P., Li G., Heintz M.J., and G.M. Hieftje, Precision and interferences in atomic time -of-flight
mass spectrometry.

3rd Rio Symposium on Atomic Spectrometry, 11/6-12/94, Caracas, Venezu
Hieftje G.M., Li G., Mahoney P.P., and D.P. Myers, Plasma source time-of-flight mass spectrometry for elemental
                                                           26



analysis.
Myers D.P., Mahoney P.P., Li G., and G.M. Hieftje, Toward higher sensitivity in atomic TOFMS

								
To top