Pump Template.xls

Reviews
Shared by: RobbiePaul
Stats
views:
34
rating:
not rated
reviews:
0
posted:
7/1/2009
language:
English
pages:
0
CENTRIFUGAL PUMP DATA SHEET Company: Project: Rev Note: Service: Item No: Date: Reflux Pump RefluxPump 4/2/09 Ref: 020908-C Rev: TBD PROCESS AND PERFORMANCE DATA Fluid: Normal Capacity (gpm ) % Total Solids: Specific Gravity: Temperature (°F): HEAD Static (ft of Liquid) Pressure (ft of Liquid.) Friction (ft of Liquid.) Total (ft of Liquid.) Normal Suction Press (psig): NASH Available (ft of Liquid.) Included: Type: Standard: Jacket: Jacket Fluid: Nozzles Suction: Discharge: Casing Support: Baseplate: Lubrication: Oil Seal: Coupling: Coupling Guard: Foot Mounted Grouted Oil Reservoir Labyrinth Elastomeric OSHA APPROVED Single Mechanical Seal Double Tandem MFG type, mat'l code Flush Plan No. Seal Flush Seal Chamber Pump --- Total BHP Required: Motor ---- Type: Electricity --- Voltage: Electrical Area --- Class: Casing Impeller Shaft Shaft Sleeve Baseplate Gaskets Roughly equivalent to Goulds 3196 Vendor to Determine 460 I 316 SS or Better 316 SS or Better Flush Fluid Double Seal with Barrier Fluid: Enlarged Cylindrical Enlarged Tapered Stuffing Box Efficiency: HP: Hertz: Group: MATERIALS OF CONSTRUCTION Containment Shell Inner Sleeve Bearing Outer Sleeve Bearing Inner Magnet Outer Magnet Jacket 60 D RPM: Phase: Div: 3 II @ ANSI psig API °F Pusher Metal Bellows Rubber Bellows Centerline Mounted Stilt Mounted Oil Mist Lip Disc Carbon Steel Drip Lip Grease Magnetic Taper lock bore Stainless Steel Cartridge Mount Component Mount Seal Hardware Straight bore Other Rotating Ring: Stationary Ring: Seals/O-ring: Size Rating Face Seal End Suction ANSI Full Casing Motor In Line API Partial Casing 0.00 0.00 -51.9 Baseplate Other Coupling Self Priming Impeller: Rear Cover/Seal Chamber @ Casing Taps Vent: Drain: None psig Size Rating °F Facing Disc Canned Motor Open Mag Drive Semi Open Multistage Closed 0.00 Normal Discharge Press (psig): Pump Design Head (ft of Liquid.) MECHANICAL DETAILS Recessed Impeller Light Hydrocarbons 2.3 Design Capacity (gpm): 0.00 % TS Dissolved: 0.00 % TS Suspended: 0.70 Viscosity (cP): Vapor Pressure (psig): 30.3 SUCTION DISCHARGE 2.8 0.00 0.63 PID No: Area: TBD AREA3 Process Engineering Associates, LLC Data Sheet No.: Project No.: Max. Particle Size: 99.5 DIFFERENTIAL 0.00 0.00 0.00 0.00 0.00 0 Ft. Remarks: Selected 1700 RPM due to low NPSHa 4/2/2009 Pump Template.xls

Related docs
Inspection Report Template.xls
Views: 21  |  Downloads: 5
Registration Form Template.xls
Views: 570  |  Downloads: 13
Pump-Selection-Considerations
Views: 5  |  Downloads: 1
pump volumne consideration
Views: 47  |  Downloads: 0
posture pump
Views: 30  |  Downloads: 0
Pump
Views: 28  |  Downloads: 2
body pump
Views: 384  |  Downloads: 3
pump of the volumne
Views: 139  |  Downloads: 1
CENTRIFUGAL PUMP
Views: 173  |  Downloads: 5
PUMP SERIAL _
Views: 2  |  Downloads: 1
premium docs
Other docs by RobbiePaul
Department store
Views: 188  |  Downloads: 0
Amendment providing option to purchase
Views: 224  |  Downloads: 4
Patent for Cotton Gin info
Views: 175  |  Downloads: 1
Receipt of Application Screening Fee
Views: 287  |  Downloads: 5
Gamers
Views: 118  |  Downloads: 0
EMPLOYMENT AGREEMENT
Views: 875  |  Downloads: 90
New Markets Venture Capital
Views: 1640  |  Downloads: 168
Sample Executive Summary Eurosky
Views: 508  |  Downloads: 8
Disclosure Lead based paint hazards
Views: 257  |  Downloads: 2
Aerial Photograph of Missiles in Cuba _1962_
Views: 299  |  Downloads: 11
Business interest power to manage and control
Views: 175  |  Downloads: 0
Wyoming articles of incorporation
Views: 264  |  Downloads: 4
Sample Executive Summary govzone
Views: 359  |  Downloads: 1