Docstoc

Walmart Re-Paint

Document Sample
Walmart Re-Paint Powered By Docstoc
					Walmart Re-Paint

PREFERRED PAINTERS
PO BOX 1191
LAKE CITY, FL 32056 1191




                 Prepared By:

                 COREY J COUTURE
                 Sales Representative
                 swrep6668@sherwin.com
SCHEDULE
Exterior Finishes
   Ferrous Metal: Gloss
      First Coat: B66W00310 - Pro Industrial Pro-Cryl® Universal Primer Off White
      Second Coat: B66W00651 - Pro Industrial 0 VOC Acrylic Semi-Gloss Extra White
   Ferrous Metal: Gloss Factory Painted Sinage at Auto Ctr Overhead Door
      First Coat: B66W00651 - Pro Industrial 0 VOC Acrylic Semi-Gloss Extra White
      Second Coat: B66W00651 - Pro Industrial 0 VOC Acrylic Semi-Gloss Extra White
  Ferrous metal: Gloss Roof mounted equip framing
      First Coat: B67W00400 - EPOLN RIP OFF WHT A
      Second Coat: B62W00800 - Epolon II Multi Mil Epoxy Ultra White
      Third Coat: B62W00800 - Epolon II Multi Mil Epoxy Ultra White
  PreFinished Metal Trim: Low Sheen
      Second Coat: B71W00211 - Bond-Plex Waterbased Acrylic Coating Extra White/Tint Base
      First Coat: B71W00211 - Bond-Plex Waterbased Acrylic Coating Extra White/Tint Base
  Galvanized Trim
      First Coat: B66W00310 - Pro Industrial Pro-Cryl® Universal Primer Off White
      Second Coat: B66W00651 - Pro Industrial 0 VOC Acrylic Semi-Gloss Extra White
      Third Coat: B66W00651 - Pro Industrial 0 VOC Acrylic Semi-Gloss Extra White
  Non-Ferrous Galvanized Metal: Semi-Gloss
      Second Coat: B66W00651 - Pro Industrial 0 VOC Acrylic Semi-Gloss Extra White
      First Coat: B66W00310 - Pro Industrial Pro-Cryl® Universal Primer Off White
      Third Coat: B66W00651 - Pro Industrial 0 VOC Acrylic Semi-Gloss Extra White
  Concrete Unit Masonry: Elastomeric Coating
      First Coat: A24W00100 - Loxon® Conditioner Guide-Coat White
      Second Coat: A05W00451 - ConFlex XL High Build Coating Extra White
  Concrete Masonry Unit: A-100 Option
      First Coat: A24W00100 - Loxon® Conditioner Guide-Coat White
      Second Coat: A06W00151 - A-100® Exterior Latex Flat Extra White
  Exterior Insulation
      First Coat: A06W00151 - A-100® Exterior Latex Flat Extra White
      First Coat: A06W00151 - A-100® Exterior Latex Flat Extra White
  Fibered Cement Siding
      First Coat: A24W00300 - Loxon Concrete And Masonry Int/Ext Latex Primer White
  Exposed Timber: Semi-Transparent
      First Coat: A15T00005 - WoodScapes® Exterior Polyurethane Semi-Transparent Stain Clear Base
      Second Coat: A15T00005 - WoodScapes® Exterior Polyurethane Semi-Transparent Stain Clear Base
  Gypsum Board: Flat
      First Coat: B42W00041 - Exterior Latex Wood Primer White
      Second Coat: A06W00151 - A-100® Exterior Latex Flat Extra White
  Concrete Pavement ( Markings and Graphics)
      First Coat: 0.0TM2160 - SetFast® Acrylic Latex Traffic Marking Paint White
  Composite Sectional Overhead Door: Gloss
      First Coat: B51W00050 - PrepRite® Bonding Primer Off White
      Second Coat: B66W00211 - DTM Acrylic Coating Semi-Gloss Extra White/Tint Base


Interior Finishes
    Ferrous Metal: Gloss
      First Coat: B66W00310 - Pro Industrial Pro-Cryl® Universal Primer Off White
      Second Coat: B21W00251 - ProMar® 200 Interior Latex Gloss Extra White
      Third Coat: B21W00251 - ProMar® 200 Interior Latex Gloss Extra White
  Ferrous Metal: Semi-Gloss
     First Coat: B66W00310 - Pro Industrial Pro-Cryl® Universal Primer Off White
     Second Coat: B31W00651 - ProGreen 200 Low VOC Interior Latex Semi-Gloss Extra White
     Third Coat: B31W00651 - ProGreen 200 Low VOC Interior Latex Semi-Gloss Extra White
  Ferrous Metal: Eggshel Dryfall over Primed Overhead Structure
     First Coat: B42W00002 - Waterborne Acrylic Dry Fall Eg-Shel White
  Ferrous Metal: Eggshel Dryfall over Un-Primed Overhead Structure
     First Coat: B66W00310 - Pro Industrial Pro-Cryl® Universal Primer Off White
     Second Coat: B42W00002 - Waterborne Acrylic Dry Fall Eg-Shel White
  Ferrous Metals: S/G Hollow Metal Door Frames
     First Coat: B67W00400 - EPOLN RIP OFF WHT A
     Second Coat: B67W00400 - EPOLN RIP OFF WHT A
  Galvanized Metal: Egg-Shell Dryfall Ductwork (Exposed)
     First Coat: B66W00310 - Pro Industrial Pro-Cryl® Universal Primer Off White
     Second Coat: B42W00002 - Waterborne Acrylic Dry Fall Eg-Shel White
  Concrete Unit Masonry: Gloss
     First Coat: B25W00025 - PrepRite® Block Filler White
     Second Coat: B21W00251 - ProMar® 200 Interior Latex Gloss Extra White
  Gypsum Board: Gloss
     First Coat: B28W00600 - ProGreen 200 Low VOC Interior Latex Primer White
     Second Coat: B21W00251 - ProMar® 200 Interior Latex Gloss Extra White
     Third Coat: B21W00251 - ProMar® 200 Interior Latex Gloss Extra White
  Gypsum Board: SemiGloss
     First Coat: B28W00600 - ProGreen 200 Low VOC Interior Latex Primer White
     Second Coat: B31W00651 - ProGreen 200 Low VOC Interior Latex Semi-Gloss Extra White
     Third Coat: B31W00651 - ProGreen 200 Low VOC Interior Latex Semi-Gloss Extra White
  Gypsum Board: Eggshel
     First Coat: B28W00600 - ProGreen 200 Low VOC Interior Latex Primer White
     Second Coat: B20W00651 - ProGreen 200 Low VOC Interior Latex Eg-Shel Extra White
     Third Coat: B20W00651 - ProGreen 200 Low VOC Interior Latex Eg-Shel Extra White
  Wood: SemiGloss
     First Coat: B28W00600 - ProGreen 200 Low VOC Interior Latex Primer White
     Second Coat: B31W00651 - ProGreen 200 Low VOC Interior Latex Semi-Gloss Extra White
     Third Coat: B31W00651 - ProGreen 200 Low VOC Interior Latex Semi-Gloss Extra White
  Wood: SemiGloss Exposed Laminated Wood Roof Structure
     First Coat: B51W00020 - PrepRite® ProBlock® Interior Exterior Latex Primer Sealer White
     Second Coat: B31W00651 - ProGreen 200 Low VOC Interior Latex Semi-Gloss Extra White
     Third Coat: B31W00651 - ProGreen 200 Low VOC Interior Latex Semi-Gloss Extra White
  Wood: Transparent Finish
     First Coat: B26V00043 - Wood Classics® FastDry Sanding Sealer Clear
  Concrete Floors: Egg-Shell
     First Coat: A32W00151 - Porch & Floor Enamel Extra White
     Second Coat: A32W00151 - Porch & Floor Enamel Extra White
END OF SECTION
Data Pages
                    Protective                                                    PRO-CRYL®
                       &                                                   UNIVERSAL PRIMER
                     Marine
                    Coatings                                                                                             B66-310 SERIES

  Revised 9/09                                                                                                                          1.23

                   PRODUCT DESCRIPTION                                                        RECOMMENDED USES
PRO-CRYL UNIVERSAL PRIMER is an advanced technology,                    For use over prepared steel in industrial environments.
                                                                        • Interior and exterior
self cross-linking acrylic primer. It is rust inhibitive and designed   • Barrier coating
for both construction and maintenance applications. It can be used      • Shop or field application
as a primer under water-based or solvent-based high performance         • As a substitute for solvent based, universal primers
topcoats.                                                               • Can be used as a dryfall coating under certain environmental
                                                                          conditions (see Application Bulletin)
• Rust inhibitive
• Flash rust / early rust resistant                                     Can be used in a variety of applications, including:
• Low odor, low VOC                                                     • Railings                       • Storage tank exteriors
• Single component                                                      • Machinery                      • Bar joists
                                                                        • Structural steel               • Piping
• Early moisture resistant                                              • Steel decking                  • Rail cars
• Fast dry                                                              • Marine vessels
• Low temperature application                                           • Suitable for use in USDA inspected facilities
• Outstanding application characteristics                               • Conforms to AWWA D102-03 OCS #3
                                                                        • Acceptable for use in high performance architectural applications.
                PRODUCT CHARACTERISTICS                                               PERFORMANCE CHARACTERISTICS
Finish:                     Low sheen
                                                                        Substrate*: Steel
Color:                      Off White, Gray, Red Oxide                  Surface Preparation*: SSPC-SP10
Volume Solids:              39% ± 2%                                    System Tested*:
Weight Solids:              53% ± 2%                                      1 ct. Pro-Cryl Universal Primer @ 3.0 mils (75 microns)

VOC (EPA Method 24):        Unreduced: <100g/L; <0.83 lb/gal              1 ct. Sher-Cryl High Performance Acrylic @ 3 mils (75 microns)
                                                                        *unless otherwise noted below
          Recommended Spreading Rate per coat:
                                      Minimum         Maximum           Test Name                 Test Method               Results
 Wet mils (microns)                    5.0 125          10 250          Adhesion                  ASTM D4541                500 psi
 Dry mils (microns)                    2.0 50          4.0 100          Corrosion                 ASTM D5894, 10
 ~Coverage sq ft/gal (m2/L)           156 3.8         312 7.6                                                               Passes
                                                                        Weathering                cycles, 3,360 hours
 Theoretical coverage sq ft/gal                                         Direct Impact
 (m2/L) @ 1 mil / 25 microns dft     624 15.3                                                      ASTM D2794               >140 in. lbs.
                                                                        Resistance
    NOTE: Brush or roll application may require multiple coats to
   achieve maximum film thickness and uniformity of appearance.          Dry Heat
                                                                                                   ASTM D2485               200°F (93°C)
                                                                        Resistance
    Drying Schedule @ 6.0 mils wet (150 microns):                                                  ASTM D522, 180°
                                                                        Flexibility                                         Passes
                   @ 40°F/4.5°C      @ 77°F/25°C     @ 120°F/49°C                                  bend, 1/4" mandrel
                                      50% RH                            Moisture
 To touch:            2 hour         40 minutes       20 minutes                                   ASTM D4585, 100°F
                                                                        Condensation                                        Excellent
 To handle:           8 hours         2 hours           1 hour                                     (38°C), 1,250 hours
                                                                        Resistance
 To recoat:          16 hours         4 hours          2 hours          Pencil Hardness            ASTM D3363               H
 To cure:            45 days          30 days          14 days          Salt Fog                   ASTM B117, 1,250
 Drying time is temperature, humidity, and film thickness dependent.                                                         Passes
                                                                        Resistance                 hours
 Shelf Life:                       36 months, unopened
                                   Store indoors at 40°F (4.5°C) to
                                   100°F (38°C)
                                                                        Provides performance comparable to products formulated to federal
 Flash Point:                      >200°F (93°C), PMCC, mixed           specification: AA50557 and Paint Specification: SSPC-Paint 23.
 Reducer/Clean Up:                 Water




                                                   www.sherwin-williams.com/protective                                   continued on back
                       Protective                                                              PRO-CRYL®
                          &                                                             UNIVERSAL PRIMER
                        Marine
                       Coatings                                                                                                                B66-310 SERIES

                                                        PRODUCT INFORMATION                                                                                        1.23

                     RECOMMENDED SYSTEMS                                                                   SURFACE PREPARATION
                                                 Dry Film Thickness / ct.
                                                  Mils        (Microns)            Surface must be clean, dry, and in sound condition. Remove all
Steel / Aluminum / Galvanized:                                                     oil, dust, grease, dirt, loose rust, and other foreign material to
1 ct.    Pro-Cryl Universal Primer                 2.0-4.0      (50-100)           ensure adequate adhesion.

Acceptable topcoats for:                                                           Do not use hydrocarbon solvents for cleaning.
Light Service:
1-2 cts. Metalatex Semi-Gloss                      1.5-4.0      (38-100)           Refer to product Application Bulletin for detailed surface prepara-
 or      Industrial Enamel HS                      2.0-4.0      (50-100)           tion information.
 or      Industrial Urethane Alkyd                 2.0-4.0      (50-100)
                                                                                   Minimum recommended surface preparation:
Moderate Service:                                                                    Iron & Steel:       SSPC-SP2
1-2 cts. Sher-Cryl High Performance                                                  Aluminum:           SSPC-SP1
         Acrylic                                   2.0-4.0      (50-100)             Galvanizing:        SSPC-SP1
 or      DTM Acrylic Coating                       2.5-4.0      (63-75)                                     Surface Preparation Standards
                                                                                                         Condition of      ISO 8501-1    Swedish Std.
 or      Steel-Master 9500                         2.0-3.0      (50-75)                                  Surface           BS7079:A1     SIS055900       SSPC    NACE
 or      Hydrogloss                                2.0-4.0      (50-100)           White Metal                             Sa 3          Sa 3            SP 5    1
                                                                                   Near White Metal                        Sa 2.5        Sa 2.5          SP 10   2
 or      Pro Industrial 0 VOC Acrylic              2.5-4.0      (63-100)           Commercial Blast                        Sa 2          Sa 2            SP 6    3
                                                                                   Brush-Off Blast                         Sa 1          Sa 1            SP 7    4
 or      Pro Industrial Multi-Surface                                              Hand Tool Cleaning Rusted Rusted
                                                                                                       Pitted &
                                                                                                                           C St 2
                                                                                                                           D St 2
                                                                                                                                         C St 2
                                                                                                                                         D St 2
                                                                                                                                                         SP 2
                                                                                                                                                         SP 2
                                                                                                                                                                 -
                                                                                                                                                                 -
         Acrylic                                   1.5-2.0      (38-50)            Power Tool Cleaning Rusted Rusted       C St 3        C St 3          SP 3    -
                                                                                                       Pitted &            D St 3        D St 3          SP 3    -

Severe Service
1-2 cts. Waterbased Tile Clad Epoxy                2.5-4.0      (63-75)
                                                                                                                        TINTING
 or      Poly-Lon HP Polyurethane                  2.0-3.0      (50-75)            Do not tint.
 or      Hi-Solids Polyurethane                    3.0-4.0      (75-100)
 or      Acrolon 218 HS                            3.0-6.0      (75-150)                                 APPLICATION CONDITIONS
 or      Waterbased Acrolon 100                    2.0-4.0      (50-100)           Temperature:                         40°F (4.5°C) minimum, 120°F (49°C)
                                                                                                                        maximum
Steel:                                                                                                                  (air, surface, and material)
1 ct.    Zinc-Clad XI                              3.0-4.0      (75-100)                                                At least 5°F (2.8°C) above dew point
1 ct.    Pro-Cryl Universal Primer                 2.0-4.0      (50-100)           Relative humidity:                   85% maximum
1-2 cts. Sher-Cryl High Performance
         Acrylic                                   2.0-4.0      (50-100)           Refer to product Application Bulletin for detailed application information.

                                                                                                          ORDERING INFORMATION
                                                                                   Packaging:                           1 (3.78L) and 5 (18.9L) gallon containers
                                                                                   Weight per gallon:                   10.79 ± 0.2 lb 1.3 Kg/L

                                                                                                            SAFETY PRECAUTIONS
                                                                                   Refer to the MSDS sheet before use.

                                                                                   Published technical data and instructions are subject to change without notice.
                                                                                   Contact your Sherwin-Williams representative for additional technical data and
The systems listed above are representative of the product's use,                  instructions.
other systems may be appropriate.
                                                                                                                     WARRANTY
                                                                                   The Sherwin-Williams Company warrants our products to be free of manufactur-
                               DISCLAIMER                                          ing defects in accord with applicable Sherwin-Williams quality control procedures.
The information and recommendations set forth in this Product Data Sheet are       Liability for products proven defective, if any, is limited to replacement of the defec-
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        tive product or the refund of the purchase price paid for the defective product as
Such information and recommendations set forth herein are subject to change and    determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
pertain to the product offered at the time of publication. Consult your Sherwin-   OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
Williams representative to obtain the most recent Product Data Information and     STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
Application Bulletin.                                                              CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.


                                                             www.sherwin-williams.com/protective
                      Protective                                                         PRO-CRYL®
                         &                                                        UNIVERSAL PRIMER
                       Marine
                      Coatings                                                                                                   B66-310 SERIES

  Revised 9/09                                        APPLICATION BULLETIN                                                                       1.23

                    SURFACE PREPARATIONS                                                         APPLICATION CONDITIONS
                                                                              Temperature:                   40°F (4.5°C) minimum, 120°F (49°C)
Surface must be clean, dry, and in sound condition. Remove all                                               maximum
oil, dust, grease, dirt, loose rust, and other foreign material to                                           (air, surface, and material)
ensure adequate adhesion.                                                                                    At least 5°F (2.8°C) above dew point

Do not use hydrocarbon solvents for cleaning.                                 Relative humidity:             85% maximum

Iron and Steel:                                                                                  APPLICATION EQUIPMENT
Minimum surface preparation is Hand Tool Cleaning per SSPC-
SP2. Remove all oil and grease from the surface per SSPC-SP1.                 The following is a guide. Changes in pressures and tip sizes may
For better performance, use Commercial Blast Cleaning per                     be needed for proper spray characteristics. Always purge spray
SSPC-SP6.                                                                     equipment before use with listed reducer. Any reduction must be
                                                                              compliant with existing VOC regulations and compatible with the
Aluminum:                                                                     existing environmental and application conditions.
Remove all oil, grease, dirt, oxide and other foreign material per
SSPC-SP1.                                                                     Reducer/Clean Up: .........Water

Galvanizing                                                                   Airless Spray
The surface should be weathered for 6 months prior to painting.                 Pressure.........................2000 psi
Remove all oil and grease per SSPC-SP1. Rusty galvanizing re-                   Hose...............................1/4" ID
quires a minimum of Hand Tool Cleaning per SSPC-SP2.                            Tip ...................................015" - .019"
                                                                                Filter ...............................60 mesh
Previously Painted Surfaces:                                                    Reduction .......................Not recommended
If in sound condition, clean the surface of all foreign material.
Smooth, hard or glossy coatings and surfaces should be dulled by              Conventional Spray
abrading the surface. Apply a test area, allowing paint to dry one             Gun ................................Binks 95
week before testing adhesion. If adhesion is poor, or if this products         Fluid Nozzle ...................66
attacks the previous finish, removal of the previous coating may be             Air Nozzle.......................63PB
necessary. If paint is peeling or badly weathered, clean surface to            Atomization Pressure .....60 psi
sound substrate and treat as a new surface as above.                           Fluid Pressure ................25 psi
                                                                               Reduction .......................As needed up to 5% by volume

                                                                              Brush
                                                                                Brush..............................Nylon/Polyester
                                                                                Reduction .......................Not recommended

                                                                              Roller
                                                                               Cover .............................3/8" woven solvent resistant core
                                                                               Reduction .......................As needed up to 5% by volume



                                                                              If specific application equipment is not listed above, equivalent
                                                                              equipment may be substituted.



                     Surface Preparation Standards
                   Condition of    ISO 8501-1   Swedish Std.
                   Surface         BS7079:A1    SIS055900      SSPC    NACE
White Metal                        Sa 3         Sa 3           SP 5    1
Near White Metal                   Sa 2.5       Sa 2.5         SP 10   2
Commercial Blast                   Sa 2         Sa 2           SP 6    3
Brush-Off Blast                    Sa 1         Sa 1           SP 7    4
                    Rusted
Hand Tool Cleaning Pitted & Rusted C St 2
                                   D St 2
                                                C St 2
                                                D St 2
                                                               SP 2
                                                               SP 2
                                                                       -
                                                                       -
Power Tool Cleaning Rusted Rusted C St 3
                    Pitted &       D St 3
                                                C St 3
                                                D St 3
                                                               SP 3
                                                               SP 3
                                                                       -
                                                                       -

                                                         www.sherwin-williams.com/protective                                      continued on back
                       Protective                                                             PRO-CRYL®
                          &                                                            UNIVERSAL PRIMER
                        Marine
                       Coatings                                                                                                              B66-310 SERIES

                                                        APPLICATION BULLETIN                                                                                    1.23

                   APPLICATION PROCEDURES                                                                    PERFORMANCE TIPS
Surface preparation must be completed as indicated.                                Stripe coat all crevices, welds, and sharp edges to protect against
                                                                                   early failure in these areas.
Mixing Instructions: Mix paint thoroughly to a uniform consistency
with low speed power agitation prior to use.                       When using spray application, use a 50% overlap with each pass
                                                                   of the gun to avoid holidays, bare areas, and pinholes. If necessary,
Apply paint at the recommended film thickness and spreading cross spray at a right angle
rate as indicated below:
                                                                                   Spreading rates are calculated on volume solids and do not include
          Recommended Spreading Rate per coat:                                     an application loss factor due to surface profile, roughness or po-
                                                                                   rosity of the surface, skill and technique of the applicator, method
                                            Minimum            Maximum
                                                                                   of application, various surface irregularities, material lost during
 Wet mils (microns)                          5.0 125             10 250            mixing, spillage, overthinning, climatic conditions, and excessive
 Dry mils (microns)                          2.0 50             4.0 100            film build.
 ~Coverage sq ft/gal (m2/L)                 156 3.8            312 7.6
 Theoretical coverage sq ft/gal
 (m2/L) @ 1 mil / 25 microns dft     624 15.3                                      Excessive reduction of material can affect film build, appearance,
                                                                                   and adhesion.
    NOTE: Brush or roll application may require multiple coats to
   achieve maximum film thickness and uniformity of appearance.
                                                                                   Do not use hydrocarbon solvents for cleaning.
     Drying Schedule @ 6.0 mils wet (150 microns):
                                                                                   Application of coating above maximum or below minimum
                      @ 40°F/4.5°C        @ 77°F/25°C        @ 120°F/49°C          recommended spreading rate may adversely affect coating
                                           50% RH                                  performance.
 To touch:               2 hour            40 minutes          20 minutes
 To handle:              8 hours            2 hours              1 hour            Refer to Product Information sheet for additional performance
 To recoat:             16 hours            4 hours             2 hours            characteristics and properties.
 To cure:               45 days             30 days             14 days
  Drying time is temperature, humidity, and film thickness dependent.               Pro-Cryl can be used as a dryfall coating in certain environmental
                                                                                   conditions. Test product before each application. Test by spray-
                                                                                   ing 15-25 feet toward paint container. All material should readily
                                                                                   wipe clean. Temperature and humidity will affect ability to dryfall.
                                                                                   Hot surface will cause overspray to bond to surface. Always clean
                                                                                   overspray immediately from hot surfaces.




                                                                                   Refer to Product Information sheet for additional performance
                                                                                   characteristics and properties.

                                                                                                           SAFETY PRECAUTIONS
                    CLEAN UP INSTRUCTIONS                                          Refer to the MSDS sheet before use.

Clean spills and spatters immediately with soap and warm water.                    Published technical data and instructions are subject to change without notice.
Clean hands and tools immediately after use with soap and warm                     Contact your Sherwin-Williams representative for additional technical data and
water. After cleaning, flush spray equipment with Mineral Spirits                   instructions.
to prevent rusting of the equipment. Follow manufacturer's safety
recommendations when using Mineral Spirits.
                                                                                                                    WARRANTY
                              DISCLAIMER                                           The Sherwin-Williams Company warrants our products to be free of manufacturing
                                                                                   defects in accord with applicable Sherwin-Williams quality control procedures.
The information and recommendations set forth in this Product Data Sheet are       Liability for products proven defective, if any, is limited to replacement of the de-
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        fective product or the refund of the purchase price paid for the defective product
Such information and recommendations set forth herein are subject to change and    as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
pertain to the product offered at the time of publication. Consult your Sherwin-   OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
Williams representative to obtain the most recent Product Data Information and     STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
Application Bulletin.                                                              CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

                                                           www.sherwin-williams.com/protective
                                                                                                                                            113.03

                   PRO
                    INDUSTRIAL™
                                                                                                  0 VOC ACRYLIC
                                                                                                   B66-600 SERIES
                                                                                                   B66-650 SERIES
                                                                                                                                                 GLOSS
                                                                                                                                            SEMI-GLOSS
                                                                                                   B66-660 SATIN                                  SATIN


          CHARACTERISTICS                                                           SPECIFICATIONS
                                               Steel:                                                  Concrete/Masonry:
 Pro Industrial 0 VOC Acrylic is an am-        2 cts.  Pro Industrial 0 VOC Acrylic                    2 cts.   Pro Industrial 0 VOC Acrylic
 bient cured, single component acrylic         Steel*:                                                 Drywall
 coating. It is designed for interior and      1 ct.   Pro Industrial Pro-Cryl                         1 ct.    ProGreen 200 Int. Latex Primer
 exterior industrial and commercial appli-             Universal Primer                                2 cts.   Pro Industrial 0 VOC Acrylic
 cations                                       or      DTM Acrylic Primer/Finish                       Galvanizing:
 • Chemical resistant                          or      Kem Bond HS                                     2 cts.   Pro Industrial 0 VOC Acrylic
 • Superior color and gloss retention          or      Zinc Clad Primer                                Prefinished Siding: (Baked-on
 • Outstanding early moisture resistance       2 cts.  Pro Industrial 0 VOC Acrylic                             finishes)
 • Flash rust/early rust resistant             Aluminum:                                               1 ct.    DTM Bonding Prime
 • Suitable for use in USDA inspected fa-      2 cts.  Pro Industrial 0 VOC Acrylic                    2 cts.   Pro Industrial 0 VOC Acrylic
   cilities                                    Aluminum:                                               Wood, exterior:
 • Low odor                                    1 ct.   DTM Wash Primer                                 1 ct.    A-100 Exterior Wood Primer
 • Fast dry                                    2 cts.  Pro Industrial 0 VOC Acrylic                    2 cts.   Pro Industrial 0 VOC Acrylic
 • HAPS free                                   Concrete Block:                                         Wood, interior:
                                               1 ct.   Heavy Duty Block Filler                         1 ct.    PrepRite Classic Latex Primer
                                               2 cts.  Pro Industrial 0 VOC Acrylic                    2 cts.   Pro Industrial 0 VOC Acrylic
                                               * Application of coating to unprimed steel may cause pinpoint rusting. Safety Colors, Deep Base, and Ultradeep
 Color:                  most colors           colors require a prime coat for maximum durability, adhesion, and corrosion protection.
 Recommended Spread Rate per ct:
   Wet mils:  6.0 - 12.0
                                               System Tested: (unless otherwise indicated)                                As of 09/22/08, Complies with:
   Dry mils:  2.5 - 4.0                                                                                              OTC           Yes LEED® CIv2.0        Yes
   Coverage:  140 - 225 sq ft/gal              Substrate:                 Steel
                                                                                                                     SCAQMD        Yes LEED® NCv2.2        Yes
              approximate                      Surface Preparation:       SSPC-SP10
                                                                                                                     CARB          Yes LEED® CSv2.0        Yes
 Note: Brush or roll application may require   Finish:    2 cts. Pro Industrial 0 VOC Acrylic                        MPI Spec #     No LEED® H              No
 multiple coats to achieve maximum film                                                                              NAHB           No
 thickness and uniformity of appearance.
 Drying Schedule @ 7.0 mils wet 50% RH:        Adhesion:                                               Humidity Resistance with Pro-Cryl
              @ 50°F @ 77°F @ 120°F            Method: ASTM D4541                                                Primer:
   To touch:    1 hr   30 min 5 min            Result:   1386 psi                                      Method: ASTM D4585, 1500 hours
   Tack free:  8 hrs    5 hrs 15 min                                                                   Result:   Rating 10 per ASTM D714
   To recoat: 8 hrs     5 hrs 15 min           Corrosion Weathering over Pro-Cryl                                for blistering
   To cure:   30 days 30 days 30 days                    Primer:                                                 Rating 10 per ASTM D1654
 Drying and recoat times are temperature,      Method: ASTM D5894, 1500 hours, 5                                 for corrosion
 humidity, and film thickness dependent.                 cycles
 Finish:    Gloss, Semi-Gloss and Satin        Result:   Rating 10, per ASTM D714                      Pencil Hardness:
 Flash Point:          499°F, Seta Flash                 for blistering                                Method: ASTM D3363
 Tinting with BAC or EnviroToner:                        Rating 9 per ASTM D1654                       Result:   2B
 Base             oz/gal        Strength                 for corrosion
 Extra White        0-4            100%                                                                Salt Fog Resistance with Pro-Cryl
 Deep Base         8-12            100%        Direct Impact Resistance:                                         Primer:
 Ultradeep Base 8-12               100%        Method: ASTM D2794                                      Method: ASTM B117, 1500 hours
               B66W611                         Result:   >160 in. lb                                   Result:   Rating 10 per ASTM D714
      (may vary by color and gloss)                                                                              for blistering
 VOC (EPA Method #24):                         Dry Heat Resistance:                                              Rating 9 per ASTM D1654
   Unreduced                 0 g/L; trace      Method: ASTM D2485                                                for corrosion
 Volume Solids:                  35 ± 2%       Result:   250°F
 Weight Solids:                  44 ± 2%                                                               Thermal Cycling:
 Weight per Gallon:      9.51 lb/gal ±2%       Flexibility:                                            Method: ASTM D2246, 5 cycles
                                               Method: ASTM D522, 180° bend,                           Result:  Passes
                                                            1/8" mandrel
                                               Result:      Passes
12/2008                                                www.sherwin-williams.com                                                       continued on back
113.03
PRO INDUSTRIAL™
0 VOC ACRYLIC
B66-600 SERIES                             GLOSS
B66-650 SERIES                        SEMI-GLOSS
B66-660 SERIES                              SATIN

   SURFACE PREPARATION                                     SURFACE PREPARATION                                               APPLICATION
  Surface must be clean, dry, and in sound               Wood                                                   Refer to the MSDS sheet before use
  condition. Remove all oil, dust, grease,               Surface must be clean, dry and sound.
  dirt, loose rust, and other foreign mate-              Prime with recommended primer. No                      Temperature:               50°F minimum
  rial to ensure adequate adhesion.                      painting should be done immediately af-                                         120°F maximum
                                                         ter a rain or during foggy weather. Knots                            (Air, surface, and material)
  Safety Colors, Deep Base, and Ultradeep
                                                         and pitch streaks must be scraped,                               At least 5°F above dew point
  colors require a prime coat for maximum
                                                         sanded and spot primed before full coat                Relative humidity:         85% maximum
  durability, adhesion, and corrosion pro-
  tection.                                               of primer is applied. All nail holes or small
  Do not use hydrocarbon solvents for                    openings must be properly caulked.                     The following is a guide. Changes in pres-
  cleaning.                                                                                                     sures and tip sizes may be needed for
                                                         Pre-Finished Siding:                                   proper spray characteristics. Always
  Iron & Steel                                           Remove oil, grease, dirt, oxides, and                  purge spray equipment before use with
  Minimum surface preparation is Hand                    other contaminants from the surface by                 listed reducer. Any reduction must be
  Tool Clean per SSPC-SP2. Remove all                    cleaning per SSPC-SP1 or water blast-                  compatible with the existing environmen-
  oil and grease from surface per SSPC-                  ing per NACE Standard RP-01-72. Always                 tal and application conditions.
  SP1. For better performance, use Com-                  checks for compatibility of the previously
  mercial Blast Cleaning per SSPC-SP6.                   painted surface with the new coating by                Reducer/Clean Up                              Water
  Primer recommended for best perfor-                    applying a test patch of 2 - 3 square feet.
  mance.
                                                         Allow to dry thoroughly for 1 week before              Airless Spray
  Aluminum                                               checking adhesion. DTM Bonding Primer                  Pressure ................................ 1500 psi
  Remove all oil, grease, dirt, oxide and                is required.                                           Hose ........................................ 1/4" ID
  other foreign material per SSPC-SP1.                                                                          Tip .................................. .017" - .021"
                                                         Previously Painted Surfaces                            Filter ..................................... 60 mesh
  Galvanizing                                            If in sound condition, clean the surface               Reduction .............. Not recommended
  The surface should be weathered for 6                  of all foreign material. Smooth, hard or
  months prior to painting. Remove all oil               glossy coatings and surfaces should be                 Conventional Spray
  and grease per SSPC-SP1. Rusty galva-                  dulled by abrading the surface. Apply a                Gun ...................................... Binks 95
  nizing requires a minimum of Hand Tool                 test area, allowing paint to dry one week              Fluid Nozzle ................................... 66
  Cleaning per SSPC-SP2. Prime area the                  before testing adhesion. If adhesion is                Air Nozzle .................................. 63PB
  same day as cleaned with Pro-Cryl.                     poor, additional abrasion of the surface               Atomization Pressure ................ 50 psi
                                                         and/or removal of the previous coating                 Fluid Pressure ..................... 15-20 psi
  Concrete and Masonry
                                                         may be necessary. Retest surface for ad-               Reduction .. As needed up to 12½%by volume
  For surface preparation, refer to SSPC-
  SP13/NACE 6 or ICRI 03732, CSP 1-3.                    hesion. If paint is peeling or badly weath-
  Surfaces should be thoroughly cleaned                  ered, clean surface to sound substrate                 Brush
  and dry. Surface temperatures must be                  and treat as a new surface as above.                   Brush ....................... Nylon / polyester
  at least 55°F before filling. If required for                                                                 Reduction .............. Not recommended
  a smoother finish, use Heavy Duty Block                  CLEANUP INFORMATION
  Filler, B42W46. Filler must be thoroughly                                                                     Roller
  dry before topcoating per manufacturer's                                                                      Cover ................................ 3/8" woven
                                                         Clean spills and spatters immediately with
  recommendations.                                                                                              Reduction ............. Not recommended
                                                         soap and warm water. Clean hands and
  Weathered masonry and soft or porous                                                                          If specific application equipment is listed
  cement board must be brush blasted or                  tools immediately after use with soap and
                                                         warm water. After cleaning, flush spray                above, equivalent equipment may be
  power tool cleaned to remove loosely ad-                                                                      substituted.
  hering contamination and to get to a hard,             equipment with Mineral Spirits to prevent
  firm surface. Apply one coat Loxon Con-                rusting of the equipment. Follow
  ditioner, following label recommenda-                  manufacturer's safety recommendations
  tions.                                                 when using Mineral Spirits.
                                                         NOTE: If coating is allowed to "set-up", Re-
                                                         ducer #54, R7K54, may be required for
                                                         cleaning. Follow manufacturer's safety rec-
                                                         ommendations when using Reducer #54.
 The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such
 information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams
 representative to obtain the most recent Product Data Sheet.
                        Industrial                                                                                                        4.64
                        &                                                                    EPOLON™ II
                        Marine                                                           MULTI-MIL EPOXY
                        Coatings                                   PART A             B62-800                                              SERIES
                                                                   PART B             B62V800                                            HARDENER

                                          PRODUCT INFORMATION                                                                      Revised 5/05

                      PRODUCT DESCRIPTION                                                        RECOMMENDED USES
  EPOLON II MULTI-MIL EPOXY is a high performance, interior/               For use over prepared surfaces such as:
  exterior, VOC compliant, high build, self-priming, two compo-            • Steel                      • Concrete
  nent, catalyzed polyamide epoxy. Dries to an extra tough, semi-          • Galvanized                 • Masonry
  gloss finish with maximum resistance to: alkali, abrasion,               Use on:
  substrate corrosion, moisture, severe weather conditions,                • Structural steel    • Masonry surfaces • Tank exteriors
  and industrial environments.                                             • Paper mills         • Piping            • Refineries
  • Long term durability                                                   • Bridges             • Power plants
  • Chemical resistant                                                      • Suitable for use   in USDA inspected facilities
  • Long pot life                                                          Not intended for architectural applications.
                                                                           Conforms to AWWA D102-03 OCS #5
                   PRODUCT CHARACTERISTICS                                                PERFORMANCE CHARACTERISTICS
 Finish:                        Semi-Gloss                                 System Tested: (unless otherwise indicated)
                                                                           Substrate:                 Steel
 Color:                         Wide range of colors available             Surface Preparation:       SSPC-SP10
                                                                           2 cts.     Epolon II Multi-Mil @ 5.0 mils dft/ct
 Volume Solids:                 67% ± 2%, ASTM D2697, mixed,
                                may vary by color                          Abrasion Resistance:
                                                                           Method: ASTM D4060, CS17 wheel, 1000 cycles, 1 kg load
 Weight Solids:                 81% ± 2%, ASTM D2369, mixed,               Result:    106 mg loss
                                may vary by color                          Adhesion:
                                                                           Method: ASTM D3359, Method A
 VOC (EPA Method 24):           Unreduced:         <280 g/L; 2.33 lb/gal   Result:    5A, 100% Retention
                                Reduced 6%:        <312 g/L; 2.60 lb/gal   Method: ASTM D4541
                                                                           Result:    1200 psi
 Mix Ratio:                     1:1 by volume
                                                                           Corrosion Weathering (with 1 ct Epolon II Primer):
 Recommended Spreading Rate per coat:                                      Method: ASTM D5894, 1008 hours, 3 cycles
   Wet mils:          4.5 - 9.0                                            Result:    Rating 10, per ASTM D714 for blistering
   Dry mils:          3.0 - 6.0                                                       Rating 10 per ASTM D1654 for corrosion
   Coverage:          180 - 365 sq ft/gal approximate                      Dry Heat Resistance:
 NOTE: Brush or roll application may require multiple coats to achieve     Method: ASTM D2485
 maximum film thickness and uniformity of appearance.                      Result:    250°F; intermittent 275°F
                                                                           Flame Spread Rating:
 Drying Schedule @ 4.0 mils wet @ 50% RH: (ASTM D1640)
                 @ 50°F         @ 77°F       @ 120°F                       Method: ASTM E84, Tunnel Test
   To touch:     4 hours        3 hours      1 hour                        Result:    Class A on noncombustible surfaces
   To handle:    16 hours       8 hours      3 hours                       Moisture Condensation Resistance:
   To recoat:                                                              Method: ASTM D4585, 100°F, 1500 hours
     minimum: 24 hours          18 hours     8 hours                       Result:    Rating 10 per ASTM D610 for rusting
     maximum: 6 months          6 months     6 months                                 Rating 10 per ASTM D714 for blistering
   To cure:      7 days         7 days       7 days                        Pencil Hardness:
                                                                           Method: ASTM D3363
 Pot Life:           4 hours            4 hours           1 hour           Result:    3H
                                                                           Prohesion:
 Sweat-in-Time: 15 minutes              none              none
 If maximum recoat time is exceeded, abrade surface before recoating.      Method: ASTM G53, 1500 hours
 Drying time is temperature, humidity, and film thickness dependent.       Result:    Rating 10 per ASTM D610 for rusting
                                                                                      Rating 10 per ASTM D714 for blistering
 Shelf Life:                    24 months, unopened                        Salt Fog Resistance:
                                Store indoors at 40°F to 100°F.            Method: ASTM B117, 1500 hours
                                                                           Result:    Rating 10 per ASTM D610 for rusting
 Flash Point:                   110°F, PMCC, mixed                                    Rating 10 per ASTM D714 for blistering
 Reducer/Clean Up:              Reducer #145, R7K145
                                                                           Epoxy coatings may darken or yellow following application and curing.


Epoxy              4.64                                                                                                       continued on back
                          Industrial                                                                                                                  4.64
                          &                                                                         EPOLON™ II
                          Marine                                                                MULTI-MIL EPOXY
                          Coatings                                     PART A                B62-800                                                  SERIES
                                                                       PART B                B62V800                                                HARDENER

                                             PRODUCT INFORMATION
                      RECOMMENDED SYSTEMS                                                             SURFACE PREPARATION
 Steel:                                                                         Surface must be clean, dry, and in sound condition. Remove
 1 ct.    Epolon II Rust Inhibitive Primer @ 2.0 - 4.0 mils dft                 all oil, dust, grease, dirt, loose rust, and other foreign material
 1-2 cts. Epolon II Multi-Mil Epoxy @ 3.0 - 6.0 mils dft/ct                     to ensure adequate adhesion.

                                                                                Refer to product Application Bulletin for detailed surface prepa-
 Steel:                                                                         ration information.
 1 ct.    Epolon II Rust Inhibitive Primer @ 2.0 - 4.0 mils dft
 1 ct.    Epolon II Multi-Mil Epoxy @ 3.0 - 6.0 mils dft/ct                     Minimum recommended               surface preparation:
 1-2 cts. Acrolon 218 HS Polyurethane @ 3.0 - 6.0 mils dft/ct                     Iron & Steel:                    SSPC-SP6/NACE 3, 2 mil profile
                                                                                  Galvanizing:                     SSPC-SP1
 Steel:                                                                           Concrete & Masonry:              SSPC-SP13/NACE 6, or ICRI
 2 cts.     Epolon II Multi-Mil Epoxy @ 3.0 - 6.0 mils dft/ct                                                      03732, CSP 1-3
                                                                                                                  TINTING
 Steel:
                                                                                Tint Part A with Blend-A-Color Toner at 200% strength. Five
 1 ct.    Zinc Clad II Plus @ 3.0 - 5.0 mils dft
                                                                                minutes minimum mixing on a mechanical shaker is required
 1-2 cts. Epolon II Multi-Mil Epoxy @ 3.0 - 6.0 mils dft/ct                     for complete mixing of color.

 Galvanized:                                                                                          APPLICATION CONDITIONS
 1-2 cts. Epolon II Multi-Mil Epoxy @ 3.0 - 6.0 mils dft/ct
                                                                                Temperature:                       50°F minimum, 120°F maximum
 Masonry:                                                                                                          (air, surface, and material)
 1 ct.  Kem Cati-Coat HS @ 10.0 - 20.0 mils dft                                                                    At least 5°F above dew point
                                                                                Relative humidity:                 85% maximum
 2 cts. Epolon II Multi-Mil Epoxy @ 3.0 - 6.0 mils dft/ct
                                                                                Refer to product Application Bulletin for detailed application
                                                                                information.
                                                                                                        ORDERING INFORMATION
                                                                                Packaging:
                                                                                  Parts A and B:                   1 and 5 gallon containers

                                                                                Weight per gallon:                 11.9 ± 0.2 lb
                                                                                                                   mixed, may vary with color

                                                                                                        SAFETY PRECAUTIONS
                                                                                Refer to the MSDS sheet before use.

                                                                                Published technical data and instructions are subject to
                                                                                change without notice. Contact your Sherwin-Williams repre-
 The systems listed above are representative of the product's                   sentative for additional technical data and instructions.
 use. Other systems may be appropriate.




                              DISCLAIMER                                                                        WARRANTY
                                                                                The Sherwin-Williams Company warrants our products to be free of manufactur-
The information and recommendations set forth in this Product Data Sheet are    ing defects in accord with applicable Sherwin-Williams quality control procedures.
based upon tests conducted by or on behalf of The Sherwin-Williams Company.     Liability for products proven defective, if any, is limited to replacement of the
Such information and recommendations set forth herein are subject to change     defective product or the refund of the purchase price paid for the defective
and pertain to the product offered at the time of publication. Consult your     product as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUAR-
Sherwin-Williams representative to obtain the most recent Product Data Infor-   ANTEE OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR
mation and Application Bulletin.                                                IMPLIED, STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUD-
                                                                                ING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
                      Industrial                                                                                                    4.64A
                      &                                                                     EPOLON™ II
                      Marine                                                            MULTI-MIL EPOXY
                      Coatings                                PART A                 B62-800                                            SERIES
                                                              PART B                 B62V800                                          HARDENER

                                        APPLICATION BULLETIN                                                                      Revised 5/05

                     SURFACE PREPARATION                                                       APPLICATION CONDITIONS
 Surface must be clean, dry, and in sound condition. Remove            Temperature:                             50°F minimum, 120°F maximum
 all oil, dust, grease, dirt, loose rust, and other foreign material                                            (air, surface, and material)
 to ensure adequate adhesion.                                                                                   At least 5°F above dew point

 Iron & Steel (atmospheric service)                                    Relative humidity:                       85% maximum
 Remove all oil and grease from surface by Solvent Cleaning
 per SSPC-SP1. Minimum surface preparation is Commercial
 Blast Cleaning per SSPC-SP6/NACE 3. For better perform-
 ance, use Near White Metal Blast Cleaning per SSPC-SP10/
 NACE 2. Blast clean all surfaces using a sharp, angular abra-                                  APPLICATION EQUIPMENT
 sive for optimum surface profile (2 mils). Prime any bare steel
 the same day as it is cleaned.                                        The following is a guide. Changes in pressures and tip sizes
                                                                       may be needed for proper spray characteristics. Always purge
 Galvanized Steel                                                      spray equipment before use with listed reducer. Any reduction
 Allow to weather a minimum of six months prior to coating.            must be compliant with existing VOC regulations and com-
 Remove all oil and grease from surface by Solvent Cleaning            patible with the existing environmental and application condi-
 per SSPC-SP1 (recommended solvent is VM&P Naphtha).                   tions.
 When weathering is not possible, or the surface has been
 treated with chromates or silicates, first Solvent Clean per          Reducer/Clean Up ........... Reducer #145, R7K145
 SSPC-SP1 and apply a test patch. Allow paint to dry at least
 one week before testing adhesion. If adhesion is poor, brush          Airless Spray
 blasting per SSPC-SP7 is necessary to remove these treat-               Pressure ......................        2700 - 3000 psi
 ments. Rusty galvanizing requires a minimum of Hand Tool                Hose ............................      3/8" ID
 Cleaning per SSPC-SP2, prime the area the same day as                   Tip ................................   .017" - .021"
 cleaned.                                                                Filter .............................   60 mesh
                                                                         Reduction .....................        As needed up to 6% by volume
 Concrete and Masonry
 For surface preparation, refer to SSPC-SP13/NACE 6, or ICRI           Conventional Spray
 03732, CSP 1-3. Surfaces should be thoroughly clean and                Gun ............................... Binks 95
 dry. Concrete and mortar must be cured at least 28 days @              Fluid Nozzle .................. 68
 75°F. Remove all loose mortar and foreign material. Surface            Air Nozzle ...................... 68PB
 must be free of laitance, concrete dust, dirt, form release            Atomization Pressure .. 50 psi
 agents, moisture curing membranes, loose cement and hard-              Fluid Pressure ............. 20 psi
 eners. Fill bug holes, air pockets and other voids with                Reduction ..................... As needed up to 6% by volume
 ArmorSeal Crack Filler. Weathered masonry and soft or po-
 rous cement board must be brush blasted or power tool                 Brush
 cleaned to remove loosely adhering contamination and to get             Brush ............................ Nylon/Polyester or Natural Bristle
 to a hard, firm surface. Laitance must be removed by etching            Reduction ..................... As needed up to 6% by volume
 with a 10% muriatic acid solution and thoroughly neutralized
 with water.                                                           Roller
 Brick must be allowed to weather for one year prior to surface         Cover ............................ 3/8" - 1/2" woven with phenolic core
 preparation and painting.                                              Reduction ..................... As needed up to 6% by volume

                                                                       If specific application equipment is not listed above, equiva-
                                                                       lent equipment may be substituted.




Epoxy             4.64A                                                                                                        continued on back
                          Industrial                                                                                                             4.64A
                          &                                                                         EPOLON™ II
                          Marine                                                                MULTI-MIL EPOXY
                          Coatings                                     PART A                B62-800                                                  SERIES
                                                                       PART B                B62V800                                                HARDENER

                                              APPLICATION BULLETIN
                     APPLICATION PROCEDURES                                                               PERFORMANCE TIPS
 Surface preparation must be completed as indicated.                            Stripe coat all crevices, welds, and sharp angles to prevent
                                                                                early failure in these areas.
 Mix contents of each component thoroughly with power agita-
 tion. Make certain no pigment remains on the bottom of the
 can. Then combine one part by volume of Part A with one part                   When using spray application, use a 50% overlap with each
 by volume of Part B. Thoroughly agitate the mixture with power                 pass of the gun to avoid holidays, bare areas, and pinholes. If
 agitation. Allow the material to sweat-in as indicated. Re-stir                necessary, cross spray at a right angle.
 before using.

 If reducer solvent is used, add only after both components                     Spreading rates are calculated on volume solids and do not
 have been thoroughly mixed, after sweat-in.                                    include an application loss factor due to surface profile, rough-
                                                                                ness or porosity of the surface, skill and technique of the ap-
 Apply paint at the recommended film thickness and spread-                      plicator, method of application, various surface irregularities,
 ing rate as indicated below:                                                   material lost during mixing, spillage, overthinning, climatic
 Recommended Spreading Rate per coat:                                           conditions, and excessive film build.
   Wet mils:          4.5 - 9.0
   Dry mils:          3.0 - 6.0                                                 Excessive reduction of material can affect film build, appear-
   Coverage:          180 - 365 sq ft/gal approximate                           ance, and adhesion.
 NOTE: Brush or roll application may require multiple coats to achieve
 maximum film thickness and uniformity of appearance.                           Do not apply the material beyond recommended pot life.

 Drying Schedule @ 4.0 mils wet @ 50% RH: (ASTM D1640)                          Do not mix previously catalyzed material with new.
                 @ 50°F         @ 77°F       @ 120°F
   To touch:     4 hours        3 hours      1 hour                             In order to avoid blockage of spray equipment, clean equip-
   To handle:    16 hours       8 hours      3 hours
   To recoat:                                                                   ment before use or before periods of extended downtime with
     minimum: 24 hours          18 hours     8 hours                            Reducer #145, R7K145.
     maximum: 6 months          6 months     6 months
   To cure:      7 days         7 days       7 days                             Not intended for architectural applications.
 Pot Life:             4 hours             4 hours            1 hour
                                                                                Quik-Kick Epoxy Accelerator is acceptable for use. See data
 Sweat-in-Time: 15 minutes                 none               none              page 4.99 for details.
 If maximum recoat time is exceeded, abrade surface before recoating.
 Drying time is temperature, humidity, and film thickness dependent.            Refer to Product Information sheet for additional performance
                                                                                characteristics and properties.
 Application of coating above maximum or below minimum
 recommended spreading rate may adversely affect coating
 performance.

                      CLEAN UP INSTRUCTIONS                                                              SAFETY PRECAUTIONS
 Clean spills and spatters immediately with Reducer #145,                       Refer to the MSDS sheet before use.
 R7K145. Clean tools immediately after use with Reducer #145,
 R7K145. Follow manufacturer's safety recommendations                           Published technical data and instructions are subject to
 when using any solvent.                                                        change without notice. Contact your Sherwin-Williams repre-
                                                                                sentative for additional technical data and instructions.

                              DISCLAIMER                                                                        WARRANTY
                                                                                The Sherwin-Williams Company warrants our products to be free of manufactur-
The information and recommendations set forth in this Product Data Sheet are    ing defects in accord with applicable Sherwin-Williams quality control procedures.
based upon tests conducted by or on behalf of The Sherwin-Williams Company.     Liability for products proven defective, if any, is limited to replacement of the
Such information and recommendations set forth herein are subject to change     defective product or the refund of the purchase price paid for the defective
and pertain to the product offered at the time of publication. Consult your     product as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUAR-
Sherwin-Williams representative to obtain the most recent Product Data Infor-   ANTEE OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR
mation and Application Bulletin.                                                IMPLIED, STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUD-
                                                                                ING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
                      Protective                                                                          BOND-PLEX
                         &                                               WATERBASED ACRYLIC COATING
                       Marine
                      Coatings                                                                                            B71-200 SERIES


     Revised 9/09                                                                                                                        1.27

                     PRODUCT DESCRIPTION                                                        RECOMMENDED USES
Bond-Plex WB Acrylic is a single component, waterborne acrylic,           For use over pre-finished siding in industrial environments such as:
adhesion promoting coating formulated for direct application to pre-      • Fluorocarbons (Kynar)
finished metal siding. Suitable for interior or exterior use.              • Polyester Polymers
                                                                          • Silicone Polyesters
•   Outstanding early moisture resistance
•   Outstanding exterior durability and gloss retention                   For use in markets such as:
•   Eliminates the use of a primer over pre-finished siding                • General Industrial, Petro-Chem, Power, Water
•   Fast dry                                                              • Food and beverage
•   Low odor, low VOC                                                     • Pharmaceutical
•   Very good mar resistance                                              • When a low sheen finish is required to match existing coil coated
•   Outstanding application characteristics                                 metal siding.
                                                                          • Suitable for use in USDA inspected facilities (except Aluminum).
                  PRODUCT CHARACTERISTICS                                 • Acceptable for use in high performance architectural applications.

Finish:                        White & Colors (Low Sheen)                               PERFORMANCE CHARACTERISTICS
                               Aluminum (Gloss)
Color:                         Wide range of colors available             Substrate*: Pre-Finished Siding
Volume Solids:                 Extra White        Aluminum                Surface Preparation*: SSPC-SP1
 (may vary by color)           41% ± 2%           37% ±2                  System Tested*:
Weight Solids:                 55.0% ± 2%         39.0% ± 2%               1 ct. Bond-Plex WB Acrylic @ 2-4 mils (50-100 microns)
                                                                          *unless otherwise noted below
VOC: (EPA 24)                 <100 g/L; 0. 83 lb/gal   <200g/L; 1.67
                               lb/gal (unreduced)                         Test Name                 Test Method           Results
           Recommended Spreading Rate per coat:                           Adhesion                  ASTM D4541            300 psi minimum
                                         Minimum         Maximum                                                          Rating 10 per ASTM
                                                                                                     ASTM D5894,
          White & Colors                                                  Corrosion                                       D610 for rusting ;
                                                                                                     5 cycles, 1,680
    Wet mils (microns)                   4.8 (120)        10.0 (250)      Weathering1                                     Rating10 per ASTM
                                                                                                     hours
    Dry mils (microns)                   2.0 (50)          4.0 (100)                                                      D714 for blistering
    ~Coverage sq ft/gal (m2/L)          164 (4.0)          329 (8.0)                                                      Direct: 160 in. lbs.
                                                                          Direct Impact
             Aluminum                                                                                ASTM D2794           Reverse: 160 in.
                                                                          Resistance
    Wet mils (microns)                   5.0 (125)        11.0 (275)                                                      lbs.
    Dry mils (microns)                   2.0 (50)          4.0 (100)      Dry Heat
                                                                                                     ASTM D2485           200°F (94°C)
    ~Coverage sq ft/gal (m2/L)          148 (3.6)         296 (7.3)       Resistance
    Theoretical coverage sq ft/gal                                                                   ASTM D522, 180°
    (m2/L) @ 1 mil / 25 microns dft     640 (15.7)                        Flexibility                                     Passes
                                                                                                     bend, 1/4" mandrel
       NOTE: Brush or roll application may require multiple coats to
      achieve maximum film thickness and uniformity of appearance.                                                         Rating 10 per ASTM
                                                                          Humidity                   ASTM D4585, 500      D610 for rusting ;
       Drying Schedule @ 5.0 mils wet (125 microns):                      Resistance1                hours                Rating 8 per ASTM
                      @ 50°F/10°C      @ 77°F/25°C      @ 120°F/49°C                                                      D714 for blistering
                                        50% RH                            Pencil Hardness            ASTM D3363           2B
    To touch:          1.5 hours        45 minutes       20 minutes                                                       Rating 9 per ASTM
    To handle:          6 hours          4 hours          2 hours         Salt Fog                   ASTM B117, 500       D610 for rusting ;
    To recoat:          8 hours          4 hours           2 hours        Resistance1                hours                Rating 10 per ASTM
    To cure:            14 days           7 days           5 days                                                         D714 for blistering
    Drying time is temperature, humidity, and film thickness dependent.                               ASTM D2246, 5        Rating 10 per ASTM
                                                                          Thermal Cycling
    Shelf Life:                       36 months, unopened                                            cycles               D714 for blistering
                                      (Aluminum - 12 months, unopened)
                                      Store indoors at 40°F (4.5°C) to
                                      100°F (38°C)                        Provides performance comparable to SSPC-Paint 23.
    Flash Point:                      >200°F (93°C) PMCC                  Footnotes
    Reducer/Clean Up:                 Water                               1
                                                                            with 1 ct. DTM Bonding Primer
                                                       www.sherwin-williams.com/protective                                continued on back
                       Protective                                                                                        BOND-PLEX
                          &                                                    WATERBASED ACRYLIC COATING
                        Marine
                       Coatings                                                                                                                B71-200 SERIES


                                                        PRODUCT INFORMATION                                                                                        1.27

                     RECOMMENDED SYSTEMS                                                                   SURFACE PREPARATION
                                              Dry Film Thickness / ct.
                                                Mils       (Microns)               Surface must be clean, dry, and in sound condition. Remove all
Prefinished Siding:                                                                 oil, dust, grease, dirt, loose rust, and other foreign material to
                                                                                   ensure adequate adhesion.
Fluorocarbon, Silicon Polyester, Polyester Polymers:
1-2 cts. Bond-Plex WB Acrylic        2.0-4.0 (50-100)                              Do not use hydrocarbon solvents for cleaning.
 or                                                                                Refer to product Application Bulletin for detailed surface prepara-
1 ct.    DTM Bonding Primer          2.0-5.0 (50-125)                              tion information.
1-2 cts. Bond-Plex WB Acrylic        2.0-4.0 (50-100)                              Minimum recommended surface preparation:
                                                                                      Prefinished Siding:      SSPC-SP1
                                                                                      Previously Painted:     SSPC-SP1
                                                                                                            Surface Preparation Standards
Previously Painted, Hard, Slick or Glossy Surfaces:                                                      Condition of      ISO 8501-1    Swedish Std.
1-2 cts. Bond-Plex WB Acrylic        2.0-4.0 (50-100)                                                    Surface           BS7079:A1     SIS055900       SSPC    NACE
                                                                                   White Metal                             Sa 3          Sa 3            SP 5    1
 or                                                                                Near White Metal                        Sa 2.5        Sa 2.5          SP 10   2
                                                                                   Commercial Blast                        Sa 2          Sa 2            SP 6    3
1 ct.    DTM Bonding Primer          2.0-5.0 (50-125)                              Brush-Off Blast                         Sa 1          Sa 1            SP 7    4
1-2 cts. Bond-Plex WB Acrylic        2.0-4.0 (50-100)                              Hand Tool Cleaning Rusted Rusted
                                                                                                       Pitted &
                                                                                                                           C St 2
                                                                                                                           D St 2
                                                                                                                                         C St 2
                                                                                                                                         D St 2
                                                                                                                                                         SP 2
                                                                                                                                                         SP 2
                                                                                                                                                                 -
                                                                                                                                                                 -
                                                                                   Power Tool Cleaning Rusted Rusted
                                                                                                       Pitted &
                                                                                                                           C St 3
                                                                                                                           D St 3
                                                                                                                                         C St 3
                                                                                                                                         D St 3
                                                                                                                                                         SP 3
                                                                                                                                                         SP 3
                                                                                                                                                                 -
                                                                                                                                                                 -
Always check compatibility of the previously painted surface with
the new coating by applying a test patch of 2-3 square feet. Allow                                                      TINTING
to dry thoroughly for 1 week before checking adhesion.
                                                                                   Tint with EnviroToner Colorants only at 100% strength. Five minutes
                                                                                   minimum mixing on a mechanical shaker is required for complete
                                                                                   mixing of color.
The systems listed above are representative of the product's use,
                                                                                   Do not use Blend-A-Color colorants.
other systems may be appropriate.
                                                                                   Do not tint the Aluminum.

                                                                                                         APPLICATION CONDITIONS
                                                                                   Temperature:                         50°F (10°C) minimum, 120°F (49°C)
                                                                                                                        maximum
                                                                                                                        (air, surface, and material)
                                                                                                                        At least 5°F (2.8°C) above dew point
                                                                                   Relative humidity:                   85% maximum
                                                                                   Refer to product Application Bulletin for detailed application information.

                                                                                                          ORDERING INFORMATION
                                                                                   Packaging:                           1 gallon (3.78L) and 5 gallon (18.9L)
                                                                                                                        containers
                                                                                   Weight:                              White:   10.9 ± 0.2 lb/gl           1.3 kg/L
                                                                                                                        Aluminum: 8.6 ± 0.2 lb/gl           1.0 kg/L

                                                                                                            SAFETY PRECAUTIONS
                                                                                   Refer to the MSDS sheet before use.

                                                                                   Published technical data and instructions are subject to change without notice.
                                                                                   Contact your Sherwin-Williams representative for additional technical data and
                                                                                   instructions.


                                                                                                                     WARRANTY
                               DISCLAIMER                                          The Sherwin-Williams Company warrants our products to be free of manufactur-
The information and recommendations set forth in this Product Data Sheet are       ing defects in accord with applicable Sherwin-Williams quality control procedures.
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        Liability for products proven defective, if any, is limited to replacement of the defec-
Such information and recommendations set forth herein are subject to change and    tive product or the refund of the purchase price paid for the defective product as
pertain to the product offered at the time of publication. Consult your Sherwin-   determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
Williams representative to obtain the most recent Product Data Information and     OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
Application Bulletin.                                                              STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
                                                                                   CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
                                                            www.sherwin-williams.com/protective
                      Protective                                                                               BOND-PLEX
                         &                                                    WATERBASED ACRYLIC COATING
                       Marine
                      Coatings                                                                                                    B71-200 SERIES


  Revised 9/09                                        APPLICATION BULLETIN                                                                         1.27

                    SURFACE PREPARATIONS                                                          APPLICATION CONDITIONS

Surface must be clean, dry, and in sound condition. Remove all                 Temperature:                   50°F (10°C) minimum, 120°F (49°C)
                                                                                                              maximum
oil, dust, grease, dirt, loose rust, and other foreign material to                                            (air, surface, and material)
ensure adequate adhesion.                                                                                     At least 5°F (2.8°C) above dew point

                                                                               Relative humidity:             85% maximum
Do not use hydrocarbon solvents for cleaning.
                                                                                                  APPLICATION EQUIPMENT
Pre-Finished Siding:
(Fluorocarbon, Silicone Polyester, and Polyester Polymers)
                                                                               The following is a guide. Changes in pressures and tip sizes may
Remove oil, grease, dirt, oxides, and other contaminants from the
                                                                               be needed for proper spray characteristics. Always purge spray
surface by cleaning per SSPC-SP1 or water blasting per NACE
                                                                               equipment before use with listed reducer. Any reduction must be
Standard RP-01-72 (caution: excessive blasting pressure may
                                                                               compliant with existing VOC regulations and compatible with the
cause warping, use caution). Always check for compatibility of
                                                                               existing environmental and application conditions.
the previously painted surface with the new coating by applying a
test patch of 2 - 3 square feet. Allow to dry thoroughly for 1 week
                                                                               Reducer/Clean Up: .........Water
before checking adhesion.
                                                                               Airless Spray
                                                                                 Pressure.........................2400 psi
Previously Painted Surfaces:
                                                                                 Hose...............................1/4" - 3/8" ID
Remove oil, grease, dirt, oxides, and other contaminants from the
                                                                                 Tip ...................................017" - .019"
surface by cleaning per SSPC-SP1 or water blasting per NACE
                                                                                 Filter ...............................60 mesh
Standard RP-01-72 (caution: excessive blasting pressure may
                                                                                 Reduction .......................As needed up to 10% by volume
cause warping, use caution). Always check for compatibility of
the previously painted surface with the new coating by applying a
                                                                               Conventional Spray
test patch of 2 - 3 square feet. Allow to dry thoroughly for 1 week
                                                                                Gun ................................Binks 95
before checking adhesion.
                                                                                Fluid Nozzle ...................66
                                                                                Air Nozzle.......................63PB
                                                                                Atomization Pressure .....60 psi
                                                                                Fluid Pressure ................25 psi
                                                                                Reduction .......................As needed up to 10% by volume

                                                                               Brush
                                                                                 Brush..............................Nylon / Polyester
                                                                                 Reduction .......................Not recommended
                                                                               Roller
                                                                                 Cover .............................1/4" woven solvent resistant core
                                                                                 Reduction .......................Not recommended



                                                                               If specific application equipment is not listed above, equivalent
                                                                               equipment may be substituted.




                     Surface Preparation Standards
                   Condition of    ISO 8501-1   Swedish Std.
                   Surface         BS7079:A1    SIS055900      SSPC    NACE
White Metal                        Sa 3         Sa 3           SP 5    1
Near White Metal                   Sa 2.5       Sa 2.5         SP 10   2
Commercial Blast                   Sa 2         Sa 2           SP 6    3
Brush-Off Blast                    Sa 1         Sa 1           SP 7    4
                    Rusted
Hand Tool Cleaning Pitted & Rusted C St 2
                                   D St 2
                                                C St 2
                                                D St 2
                                                               SP 2
                                                               SP 2
                                                                       -
                                                                       -
Power Tool Cleaning Rusted Rusted C St 3
                    Pitted &       D St 3
                                                C St 3
                                                D St 3
                                                               SP 3
                                                               SP 3
                                                                       -
                                                                       -

                                                         www.sherwin-williams.com/protective                                       continued on back
                       Protective                                                                                      BOND-PLEX
                          &                                                    WATERBASED ACRYLIC COATING
                        Marine
                       Coatings                                                                                                              B71-200 SERIES


                                                        APPLICATION BULLETIN                                                                                    1.27

                   APPLICATION PROCEDURES                                                                    PERFORMANCE TIPS
Surface preparation must be completed as indicated.                                Stripe coat all crevices, welds, and sharp angles to prevent early
                                                                                   failure in these areas.
Mixing Instructions: Mix paint thoroughly to a uniform consistency
with low speed power agitation prior to use.                       When using spray application, use a 50% overlap with each pass
                                                                   of the gun to avoid holidays, bare areas, and pinholes. If necessary,
Apply paint at the recommended film thickness and spreading
                                                                   cross spray at a right angle
rate as indicated below:

          Recommended Spreading Rate per coat:                                     During the early stages of drying, the coating is sensitive to rain,
                                                                                   dew, high humidity, and moisture condensation. Plan painting
                                            Minimum            Maximum
                                                                                   schedules to avoid these influences during the first 16-24 hours
       White & Colors
                                             4.8 (120)         10.0 (250)          of curing.
 Wet mils (microns)
 Dry mils (microns)                          2.0 (50)           4.0 (100)
                                                                                   Spreading rates are calculated on volume solids and do not include
 ~Coverage sq ft/gal (m2/L)                 164 (4.0)           329 (8.0)
                                                                                   an application loss factor due to surface profile, roughness or po-
          Aluminum
                                             5.0 (125)         11.0 (275)          rosity of the surface, skill and technique of the applicator, method
 Wet mils (microns)
                                                                                   of application, various surface irregularities, material lost during
 Dry mils (microns)                          2.0 (50)           4.0 (100)
                                                                                   mixing, spillage, overthinning, climatic conditions, and excessive
 ~Coverage sq ft/gal (m2/L)                 148 (3.6)          296 (7.3)
 Theoretical coverage sq ft/gal                                                    film build.
 (m2/L) @ 1 mil / 25 microns dft     640 (15.7)
    NOTE: Brush or roll application may require multiple coats to                  Excessive reduction of material can affect film build, appearance,
   achieve maximum film thickness and uniformity of appearance.                     and adhesion.

     Drying Schedule @ 5.0 mils wet (125 microns):                                 Do not use hydrocarbon solvents for cleaning. When clean-
                       @ 50°F/10°C        @ 77°F/25°C        @ 120°F/49°C          ing the surface per SSPC-SP1, use only an emulsifying industrial
                                           50% RH                                  detergent, followed by a thorough water rinse.
 To touch:              1.5 hours          45 minutes          20 minutes
 To handle:              6 hours            4 hours             2 hours            Always check compatibility of the previously painted surface with
 To recoat:              8 hours            4 hours              2 hours           the new coating by applying a test patch of 2-3 square feet. Allow
 To cure:                14 days             7 days              5 days            to dry thoroughly for 1 week before checking adhesion.
  Drying time is temperature, humidity, and film thickness dependent.
Application of coating above maximum or below minimum
recommended spreading rate may adversely affect coating
performance.
                                                                                   Refer to Product Information sheet for additional performance
                                                                                   characteristics and properties.

                                                                                                           SAFETY PRECAUTIONS
                                                                                   Refer to the MSDS sheet before use.
                    CLEAN UP INSTRUCTIONS
Clean spills and spatters immediately with soap and warm water.                    Published technical data and instructions are subject to change without notice.
Clean hands and tools immediately after use with soap and warm                     Contact your Sherwin-Williams representative for additional technical data and
water. After cleaning, flush spray equipment with Mineral Spirits                   instructions.
to prevent rusting of the equipment. Follow manufacturer's safety
recommendations when using Mineral Spirits.                                                                         WARRANTY
                                                                                   The Sherwin-Williams Company warrants our products to be free of manufacturing
                              DISCLAIMER                                           defects in accord with applicable Sherwin-Williams quality control procedures.
                                                                                   Liability for products proven defective, if any, is limited to replacement of the de-
The information and recommendations set forth in this Product Data Sheet are       fective product or the refund of the purchase price paid for the defective product
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
Such information and recommendations set forth herein are subject to change and    OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
pertain to the product offered at the time of publication. Consult your Sherwin-   STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
Williams representative to obtain the most recent Product Data Information and     CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Application Bulletin.

                                                           www.sherwin-williams.com/protective
                                                                                                                                108.20
                                      MASONRY
                                      COATING SYSTEMS
                                       OATING YSTEMS
                             Concrete Solutions. Solid Results.




     As of 09/22/08, Complies with:
                                                                            LOXON® CONDITIONER
OTC           Yes LEED® CIv2.0        No
SCAQMD
CARB
              Yes LEED® NCv2.2
              Yes LEED® CSv2.0
                                      No
                                      No                                                                 A24-100 SERIES
MPI Spec #     No LEED® H             No
NAHB           No



         CHARACTERISTICS                                      SPECIFICATION                               SURFACE PREPARATION
  Loxon® Conditioners are 100% acrylic             Concrete, Stucco, Block                               WARNING! Removal of old paint by sand-
  emulsion conditioners that will penetrate        1 ct. Loxon Conditioner                               ing, scraping or other means may gener-
  and seal interior and exterior surfaces          2 cts. Appropriate architectural topcoat              ate dust or fumes that contain lead. Expo-
  and bond light chalk to the surface. These              within 7 days                                  sure to lead dust or fumes may cause brain
  sealers allow new concrete, stucco, and                                                                damage or other adverse health effects,
  other cementitious surfaces to be coated         For maximum resistance to efflores-                   especially in children or pregnant women.
  prior to a 30 day cure, and will adhere to       cence, you must topcoat with Loxon                    Controlling exposure to lead or other haz-
  new or existing concrete with a pH of 6 to       Masonry Coating. Other topcoats can                   ardous substances requires the use of
  13.                                              be used, but first apply Loxon Ma-                    proper protective equipment, such as a
                                                   sonry Primer as an intermediate coat                  properly fitted respirator (NIOSH approved)
  Color:      Clear and Guide Coat White           for best protection against efflores-                 and proper containment and cleanup. For
  Coverage:              200-300 sq ft/gal         cence.                                                more information, call the National Lead
  Drying Time, @ 77°F, 50% RH:                                                                           Information Center at 1-800-424-LEAD (in
  Drying and recoat times are temperature,                      APPLICATION                              US) or contact your local health authority.
  humidity and film thickness dependent.                                                                 New and Previously Painted
    Touch:                      30 minutes         Do not build a surface glaze.                         Remove all surface contamination (peel-
    Tack free:                       1 hour        Do not apply to a damp surface.                       ing paint, heavy chalk, efflorescence,
    Recoat:                         3 hours        Do not apply over heavy chalk.                        laitance, concrete dust, etc.) by washing
  Flash Point:              >200°F, PMCC           Do not apply if the surface temperature is            or pressure washing with an appropriate
  Finish:                 0-10 units @ 85°         below 50°F, when rain is expected within              cleaner, rinse thoroughly and allow to
  Tinting with Blend-A-Color:                      3 hours, or when the relative humidity is             dry. Existing peeled or checked paint
  Guide-Coat White up to 1 oz.          N/A        90% or more.                                          should be scraped and sanded to a sound
  Vehicle Type:                      Acrylic                                                             surface.
                  A24W100                          No reduction necessary.
  VOC:                  93 g/L; 0.78 lb/gal        Brush                                                 Concrete, Stucco, Block
  Volume Solids:                   19 ± 2%         Use a nylon/polyester or foam brush.                  All new surfaces must cure for at least 7
  Weight Solids:                   26 ± 2%         Roller                                                days. Remove all dirt, dust, grease, oil,
  Weight per Gallon:                  9.1 lb       Use a 3/8" to 3/4" nap synthetic cover.               loose particles, laitance, foreign material,
                                                   Spray—Airless                                         and form release and curing agents.
                                                   Pressure ........................ 700-1000 psi
                                                   Tip ................................. .015" - .019"   Mildew
                                                                                                         Remove before painting by washing with
                                                                                                         a solution of 1 part liquid bleach and 3
                                                                                                         parts water. Apply the solution and scrub
                                                                                                         the mildewed area. Allow the solution to
                                                                                                         remain on the surface for 10 minutes.
                                                                                                         Rinse thoroughly with water and allow the
                                                                                                         surface to dry before painting. Wear pro-
                                                                                                         tective eyewear, waterproof gloves, and
                                                                                                         protective clothing. Quickly wash off any
                                                                                                         of the mixture that comes in contact with
                                                                                                         your skin. Do not add detergents or am-
                                                                                                         monia to the bleach/water solution.



9/2008                                                     www.sherwin-williams.com                                               continued on back
108.20


LOXON® CONDITIONER
A24-100 SERIES

 SURFACE PREPARATION                                           CAUTIONS
Priming                                      For interior and exterior use.
For better performance on masonry,           Protect from freezing.
Loxon Masonry Primer (exterior) or
PrepRite® Masonry Primer (interior)          Loxon Conditioners must be topcoated
will provide a hiding coat with excellent    within 7 days or the surface may need to
film build. Both can be applied to new or    be recleaned.
existing concrete with a pH of 6 to 13.
                                             CAUTION contains CRYSTALLINE SILICA. Use only
                                             with adequate ventilation. To avoid overexposure,
 CLEANUP INFORMATION                         open windows and doors or use other means to
                                             ensure fresh air entry during application and drying. If
                                             you experience eye watering, headaches, or dizzi-
Clean spills and spatters immediately with   ness, increase fresh air, or wear respiratory protection
soap and warm water. Clean hands and         (NIOSH approved) or leave the area. Adequate ven-
tools immediately after use with soap and    tilation required when sanding or abrading the dried
                                             film. If adequate ventilation cannot be provided wear
warm water. Flush spray equipment after      an approved particulate respirator (NIOSH approved).
cleaning with mineral spirits to prevent     Follow respirator manufacturer’s directions for respi-
rusting of the equipment. Follow             rator use. Avoid contact with eyes and skin. Wash
                                             hands after using. Keep container closed when not in
manufacturer's safety recommendations        use. Do not transfer contents to other containers for
when using mineral spirits.                  storage. FIRST AID: In case of eye contact, flush
                                             thoroughly with large amounts of water. Get medical
                                             attention if irritation persists. If swallowed, call Poison
                                             Control Center, hospital emergency room, or physi-
                                             cian immediately. DELAYED EFFECTS FROM LONG
                                             TERM OVEREXPOSURE. Abrading or sanding of the
                                             dry film may release crystalline silica which has been
                                             shown to cause lung damage and cancer under long
                                             term exposure. WARNING: This product contains
                                             chemicals known to the State of California to cause
                                             cancer and birth defects or other reproductive harm.
                                             DO NOT TAKE INTERNALLY. KEEP OUT OF THE
                                             REACH OF CHILDREN.
                                             HOTW           09/22/2008 A24W00100               14 00




                                             The information and recommendations
                                             set forth in this Product Data Sheet are
                                             based upon tests conducted by or on
                                             behalf of The Sherwin-Williams Com-
                                             pany. Such information and recommen-
                                             dations set forth herein are subject to
                                             change and pertain to the product offered
                                             at the time of publication. Consult your
                                             Sherwin-Williams representative to obtain
                                             the most recent Product Data Sheet.
                                                                                                                                   102.33
                                       MASONRY
                                       COATING SYSTEMS
                             Concrete Solutions. Solid Results.
                                                                                                           CONFLEX XL
As of 09/18/2008, Complies with:
                                                                                             SMOOTH ELASTOMERIC
OTC            Yes LEED® CIv2.0 N/A
SCAQMD
CARB
               Yes LEED® NCv2.2 N/A
               Yes LEED® CSv2.0 N/A
                                                                                              HIGH BUILD COATING
MPI Spec #
NAHB
                No LEED® H
               N/A
                                 N/A
                                                                                                  A5-400 SERIES
          CHARACTERISTICS                           PHYSICAL PROPERTIES                                   SURFACE PREPARATION
 ConFlex XL High Build Coating is an             Wind-Driven Rain Test .............. Passes             WARNING! Removal of old paint by sand-
 elastomeric coating that provides excel-          ASTM D6904-03                                         ing, scraping or other means may gener-
 lent flexibility, durability, and weather re-     1 ct Loxon Primer at 3.2 mils dft                     ate dust or fumes that contain lead. Ex-
 sistance. This product will protect against       2 cts ConFlex XL at 6.0-7.5 mils dft/ct               posure to lead dust or fumes may cause
 wind-driven rain when used on tilt-up, pre-     Water Vapor Permeance ..... 13.4 perms                  brain damage or other adverse health ef-
                                                   Based on ASTM D1653                                   fects, especially in children or pregnant
 cast, or poured-in-place concrete, CMU,
                                                   1 ct ConFlex XL at 9.4 mils dft,                      women. Controlling exposure to lead or
 and stucco.
                                                   14 day cure @ 77°F & 50% RH                           other hazardous substances requires the
 This may be applied to a surface with a         Elongation ..................................... 350%   use of proper protective equipment, such
 pH of 6 to 12.                                    ASTM D2370                                            as a properly fitted respirator (NIOSH ap-
                                                   1 ct ConFlex XL at 9.4 mils dft,                      proved) and proper containment and
 Color:                         Most colors        14 day cure @ 77°F & 50% RH                           cleanup. For more information, call the
 Two coat system, brush, roller, or              Tensile Strength ......................... 350 psi      National Lead Information Center at 1-
 spray applied, coverage per coat:                 ASTM D2370                                            800-424-LEAD (in US) or contact your
                         100-125 sq ft/gal         1 ct ConFlex XL at 9.4 mils dft,                      local health authority.
   13.0 - 16.0 mils wet; 6.0 - 7.5 mils dry        14 day cure @ 77°F & 50% RH
 1 coat system, spray applied,                   Freeze - Thaw Resistance ......... Passes               Remove all surface contamination by
                                                   Based on ASTM D2243                                   washing with an appropriate cleaner,
 coverage per coat:
                                                 Low Temperature Flexibility ..... Passes                rinse thoroughly and allow to dry. Exist-
                            50-60 sq ft/gal
                                                   ASTM D522 - Method B @ 10°F                           ing peeled or checked paint should be
  27.0 - 32.0 mils wet; 13.0 - 15.0 mils dry                                                             scraped and sanded to a sound surface.
 Can be applied up to 40 mils wet.                                                                       Glossy surfaces should be sanded dull.
 Coverage will vary with the substrate
                                                           SPECIFICATIONS
                                                                                                         Stains from water, smoke, ink, pencil,
 and the texture.                                                                                        grease, etc. should be sealed with the
                                                 A total dry film thickness of 12 - 15 mils
 Drying Time, @ 77°F, 50% RH:                                                                            appropriate primer/sealer.
                                                 of topcoat and a surface with 10 or less
 temperature and humidity dependent              pinholes per square foot is required                    Concrete, Stucco
   Touch:                           4 hours      for a waterproofing system.                             Pressure clean to remove all dirt, dust,
   Recoat:                        24 hours       Concrete, Stucco                                        grease, oil, loose particles, laitance, for-
 Flash Point:                           N/A      1 ct. Loxon Concrete & Masonry Primer                   eign material, peeling and defective coat-
 Finish:                 0-10 units @ 85°        1-2 cts ConFlex XL High Build Coating                   ings, chalk, form release agents, mois-
 Tinting with Blend-A-Color:                     Concrete Block, CMU, Split-face Block                   ture curing membranes, etc. Remove all
 Base              oz/gal         Strength       1 ct. Loxon Block Surfacer                              mildew. Allow the surface to dry thor-
 Extra White Base 0-5                 100%       2 cts ConFlex XL High Build Coating                     oughly. Concrete and mortar must be
 Deep Base          4-12              100%       (2 coats recommended due to the typical                 cured at least 7 days at 75°F. On tilt-up
 Ultradeep          4-12              100%              porosity of these surfaces)                      and poured-in-place concrete, commer-
 Vehicle Type:                       Acrylic     Previously Coated                                       cial detergents and sandblasting may be
                                                 After power washing, apply 1 coat of                    necessary to remove sealers, release
               A05W00451
                                                 Loxon Conditioner to tie any chalk to the               compounds, and to provide an anchor
 VOC (less exempt solvents):
                                                 surface.                                                pattern. Fill bugholes, air pockets, cracks,
                        48 g/L; 0.40 lb/gal
                                                                                                         and other voids with an elastomeric patch
 Volume Solids:                    47 ± 2%       The substrate and its condition will de-                or sealant.
 Weight Solids:                    62 ± 2%       termine the application procedure. To                   Masonry surfaces must be dry, 15% or
 Weight per Gallon:                  11.4 lb     minimize pinholes:                                      less of water, and within a pH range of 6
                                                 • 2 coat application with overnight drying              to 12. If the pH is above 12, prime the
 Mildew Resistant
                                                   between coats                                         surface first with Loxon Primer or Loxon
 This coating contains agents which inhibit
                                                 • Spray application with backrolling                    Surfacer.
 the growth of mildew on the surface of
 this coating film.                              • Power rolling

12/2009                                                  www.sherwin-williams.com                                                 continued on back
102.33

CONFLEX XL
SMOOTH ELASTOMERIC
HIGH BUILD COATING
A5-400 SERIES
 SURFACE PREPARATION                             SURFACE PREPARATION                                               CAUTIONS
Sealing and Patching—After cleaning             of 1/2". In deep openings, the depth of the       For exterior use only.
the surface thoroughly, prime any bare          Sealant should be controlled with a closed        Protect from freezing.
surface with Loxon Acrylic Primer, apply        cell, “non-gassing” type backer rod. The          Non-photochemically reactive.
an elastomeric patch or sealant if needed,      backer rod should be about 1/8" wider than        Not for use on horizontal surfaces (floors,
allow to dry, then topcoat.                     the opening. Do not apply more than 1/4"          roofs, decks, etc.) where water will collect.
To improve the performance consider:            in depth in one application. If the opening       Not for use on overhead horizontal surfaces
• Use caution when preparing the sub-           is 1/4" or greater, for maximum perfor-           (under sides of balconies, soffits, etc.)
   strate to create a uniform surface.          mance, prevent 3 point adhesion with              Not for use below grade. Will not withstand
• Patch cracks, crevices, and openings          backer rods or bond breaker tape. Three           hydrostatic pressure.
   with an elastomeric patch or sealant         point adhesion problems occur in cracks
• Stripe coat all inside and outside cor-       when the sealant adheres to the walls and         CAUTION contains CRYSTALLINE SILICA, ZINC.
   ners and edges with 1 coat of ConFlex        the bottom of a crack, and a significant          Use only with adequate ventilation. If you experience
                                                                                                  eye watering, headaches, or dizziness, increase fresh
   XL High Build Coating Smooth.                amount of flexibility is lost. Two point ad-      air, or wear respiratory protection (NIOSH approved)
To repair openings and cracks:                  hesion - wall to wall in a crack - using          or leave the area. Adequate ventilation required when
No greater than 1/32" wide:                     backer rods or bond breaker tape offers           sanding or abrading the dried film. If adequate ventila-
                                                                                                  tion cannot be provided wear an approved particulate
Apply one coat of Loxon Acrylic Primer and      the maximum flexibility and performance.          respirator (NIOSH approved). Follow respirator
follow with 1 or 2 coats of ConFlex XL High                                                       manufacturer’s directions for respirator use. Avoid
Build Coating.                                             APPLICATION                            contact with eyes and skin. Wash hands after using.
From 1/32" up to 1/16" wide:                                                                      Keep container closed when not in use. Do not transfer
                                                Apply at temperatures between 50°F and            contents to other containers for storage. FIRST AID: In
Bridge over voids and small cracks up to        100°F. Do not reduce.                             case of eye contact, flush thoroughly with large amounts
1/16" wide with an elastomeric patch or         Brush - Use a nylon/polyester brush.              of water. Get medical attention if irritation persists. If
sealant. The product must be feathered          Avoid over-brushing which causes air
                                                                                                  swallowed, call Poison Control Center, hospital emer-
                                                                                                  gency room, or physician immediately. DELAYED
to zero at the edges using a brush, knife,      bubbles.                                          EFFECTS FROM LONG TERM OVEREXPOSURE.
or trowel, to prevent the repaired area from    Roller - Use a ½" to 1½" nap synthetic            Abrading or sanding of the dry film may release crys-
telegraphing through the subsequent fin-        roller cover. Avoid rapid rolling which
                                                                                                  talline silica which has been shown to cause lung
ishes. Do not apply more than 1/4" in depth                                                       damage and cancer under long term exposure. WARN-
                                                causes bubbling.                                  ING: This product contains chemicals known to the
in one application.                             Spray—Airless                                     State of California to cause cancer and birth defects or
From 1/16" to 3/8" wide:                        Pressure, minimum ............... 2300 psi        other reproductive harm. DO NOT TAKE INTER-
Cracks and voids between 1/16" and 3/8"         Tip, minimum ............................ .021"
                                                                                                  NALLY. KEEP OUT OF THE REACH OF CHILDREN.
                                                                                                  HOTW          02/25/2008        A05W00451         12 00
wide should be opened to a sound sur-
face. Flush out the opening to remove all
dust. If dust is still evident, seal the sur-     CLEANUP INFORMATION
face with Loxon Conditioner to bind the
dust to the surface.                            Clean spills and spatters immediately with
Fill the opening with an elastomeric patch      soap and warm water. Clean hands and
or sealant; provide a small crest over the      tools immediately after use with soap and         The information and recommendations
opening to allow for shrinkage. The prod-       warm water. After cleaning, flush spray           set forth in this Product Data Sheet are
uct must be feathered to zero at the edges      equipment with mineral spirits to prevent         based upon tests conducted by or on
using a brush, knife, or trowel, to prevent     rusting of the equipment. Follow                  behalf of The Sherwin-Williams Com-
the repaired area from telegraphing             manufacturer's safety recommendations             pany. Such information and recommen-
through the subsequent finishes. Do not         when using mineral spirits.                       dations set forth herein are subject to
apply more than 1/4" in depth in one appli-                                                       change and pertain to the product offered
cation. Allow this to cure 24 hours. The                                                          at the time of publication. Consult your
depth of the opening should be 1/2 the                                                            Sherwin-Williams representative to obtain
width of the joint, with a maximum depth                                                          the most recent Product Data Sheet.
                                                                                                                       102.02

                                                                                                                 A-100®
     As of 09/29/09, Complies with:                                                  EXTERIOR LATEX FLAT
OTC           Yes LEED® CIv2.0        N/A
SCAQMD
CARB
              Yes LEED® NCv2.2
              Yes LEED® CSv2.0
                                      N/A
                                      N/A                                                A6-100 SERIES
MPI Spec #     10 LEED® H             N/A
NAHB          N/A


          CHARACTERISTICS                                  SPECIFICATIONS                        SURFACE PREPARATION

  A-100 Exterior Latex Flat is our best           Standard latex primers cannot be used         WARNING! Removal of old paint by sand-
  quality exterior flat finish. This product is   below 50°F. See specific primer label for     ing, scraping or other means may gener-
  recommended for use on aluminum, vi-            that product’s application conditions.        ate dust or fumes that contain lead. Ex-
  nyl, and wood siding, clapboard, shakes,                                                      posure to lead dust or fumes may cause
  shingles, plywood, masonry, and metal           Aluminum & Aluminum Siding1                   brain damage or other adverse health ef-
  down to a surface and air temperature of        2 cts. A-100 Exterior Latex Flat              fects, especially in children or pregnant
  35°F.                                           Concrete Block, CMU, Split face Block         women. Controlling exposure to lead or
                                                  1 ct. Loxon Block Surfacer                    other hazardous substances requires the
  Color:                      Most colors         2 cts. A-100 Exterior Latex Flat              use of proper protective equipment, such
  Coverage:           350 - 400 sq ft/gal         Brick                                         as a properly fitted respirator (NIOSH ap-
                @ 4 mils wet; 1.2 mils dry        1 ct. Loxon Conditioner2                      proved) and proper containment and
  Drying Time, @ 50% RH:                          2 cts. A-100 Exterior Latex Flat              cleanup. For more information, call the
  temperature and humidity dependent              Cement Composition Siding/Panels              National Lead Information Center at 1-
                 @ 35-45°F      @ 45°F +          1 ct. Loxon Concrete & Masonry Primer2        800-424-LEAD (in US) or contact your
  Touch:          2 hour           2 hours        or     Loxon Conditioner2                     local health authority.
  Recoat:       24-48 hours        4 hours        2 cts. A-100 Exterior Latex Flat
  Flash Point:                         N/A        Galvanized Steel1                             Remove all surface contamination by
  Finish:                 0-5 units @ 85°         2 cts. A-100 Exterior Latex Flat              washing with an appropriate cleaner,
  Tinting with Blend-A-Color:                     Stucco, Cement, Concrete                      rinse thoroughly and allow to dry. Scrape
  Base            oz/gal         Strength         1 ct. Loxon Concrete & Masonry Primer2        and sand peeled or checked paint to a
  Extra White       0-6              100%         2 cts. A-100 Exterior Latex Flat              sound surface. Sand glossy surfaces dull.
  Light Yellow     4-12              100%         Plywood                                       Seal stains from water, smoke, ink, pen-
  Deep Base        4-12              100%         1 ct. Exterior Latex Wood Primer              cil, grease, etc. with the appropriate
  Ultradeep Base 4-12                100%         2 cts. A-100 Exterior Latex Flat              primer/sealer.
  Vehicle Type:                     Acrylic       Vinyl Siding
               A06W00151                          2 cts. A-100 Exterior Latex Flat              Aluminum and Galvanized Steel
  VOC (less exempt solvents):                     Wood                                          Wash to remove any oil, grease, or other
                       49 g/L; 0.41 lb/gal        1 ct. Exterior Oil-Based Wood Primer          surface contamination. All corrosion must
  Volume Solids:                  34 ± 2%         2 cts. A-100 Exterior Latex Flat              be removed with sandpaper, steel wool,
  Weight Solids:                  52 ± 2%                                                       or other abrading method.
                                                  1
  Weight per Gallon:                11.3 lb           On large expanses of metal siding, the
                                                      air, surface, and material temperatures   Cement Composition Siding/Panels
  Mildew Resistant                                    must be 50°F or higher.                   Remove all dirt, dust, grease, oil, loose
  This coating contains agents which inhibit
                                                  2
                                                      Not for use at temperatures under 50°F.   particles, laitance, foreign material, and
  the growth of mildew on the surface of              See specific primer label for that        peeling or defective coatings. Allow the
  this coating film.                                  product’s application conditions.         surface to dry thoroughly. If the surface
                                                                                                is new, test it for pH, if the pH is higher
                                                  1 ct.    Loxon Block Surfacer                 than 8, prime with Loxon Concrete &
                                                  1 ct.    Loxon Conditioner                    Masonry Primer.
                                                  1 ct.    Loxon Concrete & Masonry Primer
                                                  1 ct.    Exterior Latex Wood Primer
                                                  1 ct.    All Surface Enamel Latex Primer
                                                  1 ct.    Exterior Oil-Based Wood Primer

                                                  HOTW       10/07/2009    A27W00051   19 00


12/2009                                                   www.sherwin-williams.com                                       continued on back
102.02

A-100®
EXTERIOR LATEX FLAT
A6-100 SERIES

 SURFACE PREPARATION                          SURFACE PREPARATION                                                    CAUTIONS
Masonry, Concrete, Cement, Block             Mildew                                                For exterior use only.
All new surfaces must be cured accord-       Remove before painting by washing with                Protect from freezing.
ing to the supplier’s recommendations—       a solution of 1 part liquid bleach and 3              Non-photochemically reactive.
usually about 30 days. Remove all form       parts water. Apply the solution and scrub
release and curing agents. Rough sur-        the mildewed area. Allow the solution to                                   LABEL CAUTIONS
                                                                                                   CAUTION contains CRYSTALLINE SILICA and ZINC.
faces can be filled to provide a smooth      remain on the surface for 10 minutes.                 Use only with adequate ventilation. To avoid overex-
surface. If painting cannot wait 30 days,    Rinse thoroughly with water and allow the             posure, open windows and doors or use other means
allow the surface to cure 7 days and prime   surface to dry before painting. Wear pro-             to ensure fresh air entry during application and drying.
the surface with Loxon Acrylic Primer.       tective eyewear, waterproof gloves, and               If you experience eye watering, headaches, or dizzi-
                                                                                                   ness, increase fresh air, or wear respiratory protection
Cracks, voids, and other holes should be     protective clothing. Quickly wash off any             (NIOSH approved) or leave the area. Adequate ven-
repaired with an elastomeric patch or        of the mixture that comes in contact with             tilation required when sanding or abrading the dried
sealant.                                     your skin. Do not add detergents or am-               film. If adequate ventilation cannot be provided wear
                                                                                                   an approved particulate respirator (NIOSH approved).
Steel                                        monia to the bleach/water solution.                   Follow respirator manufacturer’s directions for respi-
Rust and mill scale must be removed                                                                rator use. Avoid contact with eyes and skin. Wash
using sandpaper, steel wool, or other                                                              hands after using. Keep container closed when not in
abrading method. Bare steel must be
                                                         APPLICATION                               use. Do not transfer contents to other containers for
                                                                                                   storage. FIRST AID: In case of eye contact, flush
primed the same day as cleaned.                                                                    thoroughly with large amounts of water. Get medical
Stucco                                       When the air temperature is at 35°F, sub-
                                                                                                   attention if irritation persists. If swallowed, call Poison
                                             strates may be colder; prior to painting,             Control Center, hospital emergency room, or physi-
Remove any loose stucco, efflorescence,
                                             check to be sure the air, surface, and                cian immediately. DELAYED EFFECTS FROM LONG
or laitance. Allow new stucco to cure at     material temperature are above 35°F                   TERM OVEREXPOSURE. Abrading or sanding of the
least 30 days before painting. If painting   and at least 5°F above the dew point.                 dry film may release crystalline silica which has been
cannot wait 30 days, allow the surface to    Avoid using if rain or snow is expected               shown to cause lung damage and cancer under long
dry 5-7 days and prime with Loxon Ma-                                                              term exposure. WARNING: This product contains
                                             within 2-3 hours.                                     chemicals known to the State of California to cause
sonry Primer. Repair cracks, voids, and      Do not apply at air or surface tempera-               cancer and birth defects or other reproductive harm.
other holes with an elastomeric patch or     tures below 35°F or when air or surface               DO NOT TAKE INTERNALLY. KEEP OUT OF THE
sealant.                                     temperatures may drop below 35°F within               REACH OF CHILDREN.
                                             48 hours.                                             HOTW           07/26/2007           A06W00151        05 00
Vinyl
Clean the surface thoroughly by scrub-       No reduction necessary.
bing with warm, soapy water. Rinse thor-     Brush
oughly.                                      Use a nylon/polyester brush.
                                             Roller
Wood, Plywood, Composition Board
                                             Use a 3/8" - 3/4" nap synthetic cover.
Sand any exposed wood to a fresh sur-
                                             Spray—Airless
face. Patch all holes and imperfections      Pressure ................................ 2000 psi
with a wood filler or putty and sand         Tip ................................... .015"-.019"
smooth. All patched areas must be                                                                  The information and recommendations
primed.
Caulking
                                               CLEANUP INFORMATION                                 set forth in this Product Data Sheet are
                                             Clean spills, spatters, hands and tools               based upon tests conducted by or on
Gaps between windows, doors, trim, and                                                             behalf of The Sherwin-Williams Com-
                                             immediately after use with soap and warm
other through-wall openings can be filled    water. After cleaning, flush spray equip-             pany. Such information and recommen-
with the appropriate caulk after priming     ment with mineral spirits to prevent rust-            dations set forth herein are subject to
the surface.                                 ing of the equipment.                                 change and pertain to the product offered
                                             Follow manufacturer’s safety recommen-                at the time of publication. Consult your
                                             dations when using mineral spirits.                   Sherwin-Williams representative to obtain
                                                                                                   the most recent Product Data Sheet.
                                                                                                                                    108.11
                                      MASONRY
                                      COATING SYSTEMS
                                       OATING YSTEMS
                             Concrete Solutions. Solid Results.
                                                                                                                              LOXON®
     As of 09/22/08, Complies with:
                                                                                                              ACRYLIC PRIMER
OTC
SCAQMD
CARB
              Yes LEED® CIv2.0
              Yes LEED® NCv2.2
              Yes LEED® CSv2.0
                                      No
                                      No
                                      No
                                                                                                                  A24W300
MPI Spec #      3 LEED® H             No
NAHB


         CHARACTERISTICS                              PHYSICAL PROPERTIES                                     SURFACE PREPARATION
  Loxon Acrylic Primer is an acrylic coat-         Flexibility .................................... Passes   WARNING! Removal of old paint by sand-
  ing specifically engineered for exterior,          ASTM D522 - Method B, 180° bend,                        ing, scraping or other means may gener-
  above-grade, masonry surfaces requiring            1/8" mandrel                                            ate dust or fumes that contain lead. Ex-
  a high performance primer. It is highly          Alkali Resistance ....................... Passes          posure to lead dust or fumes may cause
  alkali and efflorescence resistant. It rein-       Based on ASTM D1308                                     brain damage or other adverse health ef-
                                                   Mildew Resistance ..................... Passes
  forces the performance of exterior latex                                                                   fects, especially in children or pregnant
                                                     ASTM D3273/D3274
  paints and can be used on concrete, con-                                                                   women. Controlling exposure to lead or
  crete block, brick, and stucco. This may                                                                   other hazardous substances requires the
  be applied to a surface with a pH of 6 to                   SPECIFICATION                                  use of proper protective equipment, such
  13.                                                                                                        as a properly fitted respirator (NIOSH ap-
                                                   Must be topcoated within 14 days.                         proved) and proper containment and
  Color:                               White                                                                 cleanup. For more information, call the
                                                   Concrete, Stucco, Block                                   National Lead Information Center at 1-
  Coverage:                    200 sq ft/gal
                                                   1 ct. Loxon Acrylic Primer                                800-424-LEAD (in US) or contact your lo-
                 @ 8 mils wet; 3.2 mils dry        2 cts. Appropriate latex topcoat                          cal health authority.
  Coverage on porous & rough stucco 80             Spray and backroll on porous & rough
  square feet per gallon                           stucco to achieve required film build and                 Concrete/Stucco/Block
  Drying Time, @ 77°F, 50% RH:                     a pin-hole free surface.                                  All new surfaces must cure for at least 7
  Drying and recoat times are temperature,                                                                   days. Remove all form release and cur-
  humidity and film thickness dependent.                        APPLICATION                                  ing agents. Pressure clean (minimum
    Touch:                           4 hours                                                                 2100 psi) to remove all dirt, dust, grease,
    Recoat:                         24 hours       Apply at temperatures above 50°F.                         oil, loose particles, laitance, foreign ma-
  Flash Point:                           N/A       No reduction necessary.                                   terial, peeling and defective coatings,
                                                   Do not paint in direct sun or on a hot sur-               chalks, etc. Allow the surface to dry be-
  Finish:                  0-10 units @ 85°
                                                   face.                                                     fore proceeding. Repair cracks, voids,
  Tinting - For best color development, use
                                                   May be applied to damp but not to wet                     and other holes with ConSeal™ Patches
  the recommended "P"-shade primer. If
                                                   surfaces.                                                 and Sealants.
  desired, up to 4 oz per gallon of Blend-A-
                                                   Brush
  Color Toner can be used to approximate
                                                   Use a quality nylon/polyester brush.                      Mildew
  the topcoat color. Check color before use.
                                                   Roller                                                    Remove before painting by washing with
  Vehicle Type:                       Acrylic                                                                a solution of 1 part liquid bleach and 3
                                                   Use a quality 1/2" to 1-1/2" nap synthetic
                  A24W300                          roller cover.                                             parts water. Apply the solution and scrub
  VOC:                   97 g/L; 0.81 lb/gal       Spray—Airless                                             the mildewed area. Allow the solution to
  Volume Solids:                    40 ± 2%        Pressure ...................... 2000-2700 psi             remain on the surface for 10 minutes.
  Weight Solids:                    54 ± 2%        Tip ............................................. .019"   Rinse thoroughly with water and allow the
                                                   Reduction ................................... none        surface to dry before painting. Wear pro-
  Weight per Gallon:                  10.8 lb
                                                   Spray—Conventional                                        tective eyewear, waterproof gloves, and
                                                   Air Pressure ........................ 40-60 psi           protective clothing. Quickly wash off any
                                                   Fluid Pressure ........................... 20 psi         of the mixture that comes in contact with
                                                   Cap/Tip ................................... 704/FX        your skin. Do not add detergents or am-
                                                   Reduction ............... up to 1 pint/gallon             monia to the bleach/water solution.
                                                   Spray and backroll on porous & rough
                                                   stucco to achieve required film build and
                                                   a pin-hole free surface.


4/2009                                                     www.sherwin-williams.com                                                   continued on back
108.11

LOXON®
ACRYLIC PRIMER
A24W300

 SURFACE PREPARATION                                           CAUTIONS
Caulking                                     For exterior use only.
Gaps between windows, doors, trim, and       Protect from freezing.
other through-wall openings can be filled    Non-photochemically reactive.
with the appropriate caulk after priming
                                                                  LABEL CAUTIONS
the surface.                                 CAUTION contains CRYSTALLINE SILICA, ZINC.
                                             Use only with adequate ventilation. To avoid overex-
                                             posure, open windows and doors or use other means
 CLEANUP INFORMATION                         to ensure fresh air entry during application and drying.
                                             If you experience eye watering, headaches, or dizzi-
                                             ness, increase fresh air, or wear respiratory protection
Clean spills and spatters immediately with   (NIOSH approved) or leave the area. Adequate ven-
soap and warm water. Clean hands and         tilation required when sanding or abrading the dried
tools immediately after use with soap and    film. If adequate ventilation cannot be provided wear
warm water. After cleaning, flush spray      an approved particulate respirator (NIOSH approved).
                                             Follow respirator manufacturer’s directions for respi-
equipment with mineral spirits to prevent    rator use. Avoid contact with eyes and skin. Wash
rusting of the equipment. Follow             hands after using. Keep container closed when not in
manufacturer's safety recommendations        use. Do not transfer contents to other containers for
                                             storage. FIRST AID: In case of eye contact, flush
when using mineral spirits.                  thoroughly with large amounts of water. Get medical
                                             attention if irritation persists. If swallowed, call Poison
                                             Control Center, hospital emergency room, or physi-
                                             cian immediately. DELAYED EFFECTS FROM LONG
                                             TERM OVEREXPOSURE. Abrading or sanding of the
                                             dry film may release crystalline silica which has been
                                             shown to cause lung damage and cancer under long
                                             term exposure. WARNING: This product contains
                                             chemicals known to the State of California to cause
                                             cancer and birth defects or other reproductive harm.
                                             DO NOT TAKE INTERNALLY. KEEP OUT OF THE
                                             REACH OF CHILDREN.
                                             HOTW 09/24/2008                A24W00300          23 00




                                             The information and recommendations
                                             set forth in this Product Data Sheet are
                                             based upon tests conducted by or on
                                             behalf of The Sherwin-Williams Com-
                                             pany. Such information and recommen-
                                             dations set forth herein are subject to
                                             change and pertain to the product offered
                                             at the time of publication. Consult your
                                             Sherwin-Williams representative to obtain
                                             the most recent Product Data Sheet.
                                                                                                                          105.23
                                                WOODSCAPES® HOUSE STAIN
                                                                                EXTERIOR POLYURETHANE
OTC
     As of 09/22/08, Complies with:
              Yes LEED® CIv2.0        No                                        SEMI-TRANSPARENT STAIN
SCAQMD        Yes LEED® NCv2.2        No
CARB
MPI Spec #
              Yes LEED® CSv2.0
               No LEED® H
                                      No
                                      No                                                      A15T5
NAHB           No


         CHARACTERISTICS                               SPECIFICATIONS                                  APPLICATION
  WoodScapes® House Stain Exterior              Wood, Plywood                              When the air temperature is at 35°F, sub-
  Polyurethane Semi-Transparent pro-            2 cts. WoodScapes House Stain Exte-        strates may be colder; prior to painting,
  vides a long lasting, mildew resistant film          rior Polyurethane Semi-Transpar-    check to be sure the air, surface, and
  with excellent penetration for protecting            ent                                 material temperature are above 35°F
  most exterior wood surfaces. This prod-                                                  and at least 5°F above the dew point.
  uct can be applied at air, surface, and ma-                                              Avoid using if rain or snow is expected
                                                 Two coats are necessary to achieve
  terial temperatures as low as 35°F.
                                                 the selected color. Wait the appro-       within 2-3 hours.
                                                 priate recoat time for the first coat     Do not apply at air or surface tempera-
  Color: Semi-Transparent stain colors
  Coverage:                                      to dry.                                   tures below 35°F or when air or surface
    Rough/porous:      100-200 sq ft/gal                                                   temperatures may drop below 35°F within
    Smooth:                 350 sq ft/gal       Important: All stains tend to lap (dark    48 hours.
  Drying Time, @ 77°F, 50% RH:                  lines where two freshly coated areas
  temperature and humidity dependent            overlap). To minimize lapping:             Brush
    Touch:                       1 hour         • Do not stain in direct sun or on a hot   No reduction necessary. Use a
    Recoat:                     4 hours            surface.                                nylon\polyester brush.
  Drying Time @ 50% RH:                         • Stain from a dry area into the adjoin-
  temperature and humidity dependent                                                       Roller
                                                   ing wet stain area.                     No reduction necessary. Use a 3/8" - 3/4"
                @ 35-45°F      @ 45°F+
  Touch:          2 hour        2 hours         • Stain up and down vertical siding and    nap synthetic or lambswool roller cover.
  Recoat:      24-48 hours      5 hours            across horizontal siding.
                                                                                           Spray—Airless
  Air and surface temperatures must not drop
                                                                                           Pressure ................................ 2000 psi
  below 35°F for 48 hours after application.
  When applying a second coat, it must be ap-                                              Tip ................................... .015"-.017"
  plied within 30 days of the first coat.                                                  Reduction .... as needed up to 1 pt/gal
  Finish:                   0 units @ 85°                                                  Spray—Conventional
  Flash Point:                         N/A                                                 Air Pressure .............................. 40 psi
  Tinting with Blend-A-Color:
  Base              oz/gal       Strength                                                  Fluid Pressure ........................... 20 psi
  Clear Base        ½-4             100%                                                   Cap/Tip ................................... 704/FX
  Must be tinted for use, do not exceed 4                                                  Reduction .... as needed up to 1 pt/gal
  oz/gal of tinting color.
  Vehicle Type:              Polyurethane                                                  For the best performance, and to achieve
                   A15T5                                                                   the warranty protection, apply two coats.
  VOC (total):
                        79 g/L; 0.66 lb/gal
  VOC (less exempt solvents):                                                              When applying a second coat, it must be
                       492 g/L; 4.11 lb/gal                                                applied within 30 days of the first coat.
  Volume Solids:                   8 ± 2%
  Weight per Gallon:                 8.5 lb                                                After 30 days, test the absorbency of the
                                                                                           wood by sprinkling water on the surface.
  Mildew Resistant                                                                         If the water does not bead up and pen-
  This product contains agents which in-                                                   etrates into the wood quickly, the wood is
  hibit the growth of mildew on the surface                                                ready to refinish. If the water beads up or
  of this paint film.                                                                      does not penetrate, allow the wood to
                                                                                           weather longer and test for absorbency
                                                                                           again.



9/2008                                               www.sherwin-williams.com                                            continued on back
105.23
WOODSCAPES® HOUSE STAIN
EXTERIOR POLYURETHANE
SEMI-TRANSPARENT STAIN
A15T5
  SURFACE PREPARATION                            SURFACE PREPARATION                              CLEANUP INFORMATION
                                                                                                Clean spills, spatters, hands and tools
 WARNING! Removal of old paint by sand-         Apply appropriate patching material to          immediately after use with soap and warm
 ing, scraping or other means may gener-        cracks, nail holes, or other surface im-        water. After cleaning, flush spray equip-
 ate dust or fumes that contain lead. Expo-     perfections. Filled areas will take the stain   ment with mineral spirits to prevent rust-
 sure to lead dust or fumes may cause brain     differently than bare wood.                     ing of the equipment. Follow
 damage or other adverse health effects,                                                        manufacturer's safety recommendations
 especially in children or pregnant women.      Caulk around windows, doors, and other          when using mineral spirits.
 Controlling exposure to lead or other haz-     openings with an appropriate caulk. The
 ardous substances requires the use of          stain will appear different over caulk.                          CAUTIONS
 proper protective equipment, such as a         Consider using a caulk that is a color simi-    Maintenance clean by using a non-
 properly fitted respirator (NIOSH approved)    lar to the stain color.                         chlorinated bleach alternative.
 and proper containment and cleanup. For                                                        For exterior use only.
 more information, call the National Lead       Smooth or Rough Wood Siding and                 Do not use on composition board.
 Information Center at 1-800-424-LEAD (in       Plywood. Sand any exposed, deterio-             Do not use on roofs.
 US) or contact your local health authority.    rated wood to a fresh surface.                  Do not apply at temperatures below 35°F.
                                                                                                Not for use on horizontal surfaces, such as
 Remove all existing paint and replace any      Mill Glaze is a glossy finish on new,           a roof, or floor, where water may collect.
 deteriorated substrate. Although this can      smooth sawn wood or on the peaks of             Use DeckScapes Waterborne Semi-
 be applied over earlier semi-transparent       some textured wood. This must be re-            Transparent Deck Stain for exterior wood
 stains, some of the old color may be vis-      moved by sanding to allow the stain to          deck floors.
 ible through this semi-transparent film.       penetrate.                                                       LABEL CAUTIONS
                                                                                                Use only with adequate ventilation. To avoid overex-
 Remove all surface contamination by            Pressure Treated Wood                           posure, open windows and doors or use other means
 washing with an appropriate cleaner to                                                         to ensure fresh air entry during application and drying.
                                                Test the absorbency of the wood by sprin-       If you experience eye watering, headaches, or dizzi-
 remove all dirt, air pollution, chalk, etc.,   kling water on the surface. If the water        ness, increase fresh air, or wear respiratory protection
 especially in areas not exposed to direct      penetrates into the wood quickly, the           (NIOSH approved) or leave the area. Avoid contact
 weathering such as under eaves and             wood is ready to finish. If the water beads     with eyes and skin. Wash hands after using. Keep
 porch ceilings. Rinse and allow the sur-                                                       container closed when not in use. Do not transfer
                                                up or does not penetrate, allow the wood        contents to other containers for storage. FIRST AID: In
 face to dry. If after cleaning, the surface    to weather several weeks and test for           case of eye contact, flush thoroughly with large amounts
 still appears dirty, suspect mildew.           absorbency again. Prepare the surface           of water. Get medical attention if irritation persists. If
                                                                                                swallowed, call Poison Control Center, hospital emer-
                                                like any other wood surface.                    gency room, or physician immediately. WARNING:
 Remove mildew before painting by wash-
                                                Due to the green tone of many brands of         This product contains chemicals known to the State of
 ing with a solution of 1 pint liquid bleach                                                    California to cause cancer and birth defects or other
                                                pressure treated lumber, the color of the
 and 1 gallon water. Apply the solution                                                         reproductive harm. DO NOT TAKE INTERNALLY.
                                                stain may look different from the color
 and scrub the mildewed area. Allow the                                                         KEEP OUT OF THE REACH OF CHILDREN.
                                                selected. Check the color on a test area        HOTW 08/13/2008               A15T00005          14 00
 solution to remain on the surface for 10
 minutes. Rinse thoroughly with water and       prior to staining the entire project.           The information and recommendations
 allow the surface to dry before painting.                                                      set forth in this Product Data Sheet are
 Wear protective eyewear, waterproof                                                            based upon tests conducted by or on
 gloves, and protective clothing. Quickly                                                       behalf of The Sherwin-Williams Company.
 wash off any of the mixture that comes in                                                      Such information and recommendations
 contact with your skin. Do not add deter-                                                      set forth herein are subject to change and
 gents or ammonia to the bleach/water                                                           pertain to the product offered at the time
 solution.                                                                                      of publication. Consult your Sherwin-Wil-
                                                                                                liams representative to obtain the most
 Maintenance clean by using a non-                                                              recent Product Data Sheet.
 chlorinated bleach alternative.
                                                                                                                                 108.10
                                      Formulated for use with the
                             Color-Prime™ System
                                                                                                                           A-100®
     As of 09/22/08, Complies with:                                                 EXTERIOR LATEX PRIMER
OTC           Yes LEED® CIv2.0        No
SCAQMD        Yes LEED® NCv2.2        No                                                 B42W41 ............White and Tinting Base
CARB          Yes LEED® CSv2.0        No                                                 B42W43 ................... Deep Tinting Base
MPI Spec #     No LEED® H             No
NAHB           No


         CHARACTERISTICS                                      SPECIFICATION                               SURFACE PREPARATION
  A-100 Exterior Latex Primer is recom-            Wood, Plywood, Composition Board,                     Warning! Removing or disturbing old
  mended for use on exterior wood and ply-         Cement Composition Panels, Masonry,                   paint from interior or exterior surfaces by
  wood siding and trim, masonry, and ce-           Cement, Stucco                                        sanding, scraping, abrading or other
  ment composition panels, as a spot               1 ct. A-100 Exterior Latex Primer                     means may produce dust, debris or
  primer or overall primer, down to a sur-         2 cts. Exterior latex or alkyd topcoat                fumes that contain lead. Exposure to lead
  face and air temperature of 35°F.                Must be topcoated within 14 days.                     dust, debris or fumes may cause brain
                                                                                                         damage or other adverse health effects,
  Color:        White and custom colors                         APPLICATION                              especially in children and pregnant
  Coverage:             350 - 400 sq ft/gal                                                              women. Structures built before1978
                @ 4 mils wet; 1.4 mils dry         When the air temperature is at 35°F, sub-             should be tested by a licensed inspector
  Drying Time, 50% RH:                             strates may be colder; prior to painting,             prior to removing or disturbing old paint.
  Drying and recoat times are temperature,         check to be sure the air, surface, and                For more information, call the National
  humidity and film thickness dependent.           material temperature are above 35°F                   Lead Information Center at 1-800-424-
                     35-45°F 45-60°F 60°F+         and at least 5°F above the dew point.                 LEAD (in U. S.) or contact your local
   Touch hrs:          2          2        1       Avoid using if rain or snow is expected               health authority.
   Recoat hrs:       24-48        24       4       within 2-3 hours.
  Air and surface temperatures must not drop       Air and surface temperatures must not                 Remove all surface contamination by
  below 35°F for 48 hours after application.       drop below 35°F for 48 hours after appli-             washing with an appropriate cleaner,
  Flash Point:                          N/A        cation.                                               rinse thoroughly and allow to dry. Scrape
  Finish:                 0-10 units @ 85°                                                               and sand peeled or checked paint to a
  Tinting with Blend-A-Color:                      Apply at temperatures above 35°F.                     sound surface. Sand glossy surfaces dull.
  Base             oz/gal         Strength         No reduction necessary.                               Seal stains from water, smoke, ink, pen-
  White              0-4              100%         Brush                                                 cil, grease, etc. with the appropriate
  Deep Base         4 - 10            100%         Use a nylon/polyester brush.                          primer/sealer.
  For best color development, use the rec-         Roller
  ommended “P”-shade primer. If desired,           Use a 3/8" - 3/4" nap synthetic cover.                Wood, Plywood, Exterior Drywall
  Blend-A-Color Toner can be used to ap-           Spray—Airless                                         Sand any exposed wood to a fresh sur-
  proximate the topcoat color. Check color         Pressure ................................ 2000 psi    face. Patch all holes and imperfections
  before use.                                      Tip ................................... .019"-.021"   with a wood filler, putty, or exterior grade
  Vehicle Type:                      Acrylic                                                             spackle and sand smooth.
                B42W00041                                                                                On woods that present potential tannin
  VOC (less exempt solvents):
                                                     CLEANUP INFORMATION                                 bleeding, such as redwood and cedar,
                         87 g/L; 0.72 lb/gal                                                             A-100 Exterior Latex Primer can be used.
  Volume Solids:                   36 ± 2%         Clean spills and spatters immediately with            Care must be taken to determine if tan-
  Weight Solids:                   52 ± 2%         soap and warm water. Clean hands and                  nins will be activated by the water in the
  Weight per Gallon:                11.2 lb        tools immediately after use with soap and             coating. To test for bleeding, coat a 4 foot
                                                   warm water. After cleaning, flush spray               by 4 foot section with the primer. If no
  Mildew Resistant                                 equipment with mineral spirits to prevent             bleeding is evident within 4 hours, pro-
  This coating contains agents which inhibit       rusting of the equipment. Follow                      ceed with complete priming. If bleeding
  the growth of mildew on the surface of           manufacturer's safety recommendations                 occurs, use A-100® Exterior Oil Stain
  this coating film.                               when using mineral spirits.                           Blocking Primer.




9/2008                                                     www.sherwin-williams.com                                                continued on back
108.10

A-100®
EXTERIOR LATEX PRIMER
B42W41 ................ White and Tinting Base
B42W43 ................ Deep Tinting Base


 SURFACE PREPARATION                                               CAUTIONS
Masonry Surfaces:                                For exterior use only.
All new surfaces must be cured accord-           Protect from freezing.
ing to the supplier’s recommendations—           Non-photochemically reactive.
usually about 30 days. Remove all form           Not for use on horizontal surfaces, such
release and curing agents. If painting can-      as a roof, deck, or floor, or where water
not wait 30 days or if the pH of the sur-        may collect.
face is greater than 9, allow the surface        On large expanses of prefinished metal
to cure 7 days and prime the surface with        siding, the air, surface, and material tem-
Loxon® Masonry Primer*.                          peratures must be 50°F or higher.
Repair cracks, voids, and other holes with
ConSeal™ Patches and Sealants*.                                       LABEL CAUTIONS
                                                 CAUTION contains CRYSTALLINE SILICA, ZINC.
Cement Composition Siding/Panels                 Use only with adequate ventilation. To avoid overex-
                                                 posure, open windows and doors or use other means
Clean thoroughly. Do not pressure wash,          to ensure fresh air entry during application and drying.
the pressure may damage the panels.              If you experience eye watering, headaches, or dizzi-
Masonry, Concrete, Cement                        ness, increase fresh air, or wear respiratory protection
Rough surfaces can be filled with Loxon          (NIOSH approved) or leave the area. Adequate ven-
                                                 tilation required when sanding or abrading the dried
Block Surfacer to provide a smooth sur-          film. If adequate ventilation cannot be provided wear
face.                                            an approved particulate respirator (NIOSH approved).
Stucco                                           Follow respirator manufacturer’s directions for respi-
Remove any loose stucco, efflorescence,          rator use. Avoid contact with eyes and skin. Wash
                                                 hands after using. Keep container closed when not in
or laitance.                                     use. Do not transfer contents to other containers for
* Do not use at temperatures below 50°F          storage. FIRST AID: In case of eye contact, flush
                                                 thoroughly with large amounts of water. Get medical
Mildew                                           attention if irritation persists. If swallowed, call Poison
                                                 Control Center, hospital emergency room, or physi-
Remove before painting by washing with           cian immediately. DELAYED EFFECTS FROM LONG
a solution of 1 part liquid bleach and 3         TERM OVEREXPOSURE. Abrading or sanding of the
parts water. Apply the solution and scrub        dry film may release crystalline silica which has been
the mildewed area. Allow the solution to         shown to cause lung damage and cancer under long
                                                 term exposure. WARNING: This product contains
remain on the surface for 10 minutes.            chemicals known to the State of California to cause
Rinse thoroughly with water and allow the        cancer and birth defects or other reproductive harm.
surface to dry before painting. Wear pro-        DO NOT TAKE INTERNALLY. KEEP OUT OF THE
tective eyewear, waterproof gloves, and          REACH OF CHILDREN.
                                                 HOTW 09/18/2008                B42W00041          28 00
protective clothing. Quickly wash off any
of the mixture that comes in contact with
your skin. DO NOT ADD DETERGENTS                 The information and recommendations
OR AMMONIA TO THE BLEACH/WA-                     set forth in this Product Data Sheet are
TER SOLUTION.                                    based upon tests conducted by or on
                                                 behalf of The Sherwin-Williams Com-
Caulking
                                                 pany. Such information and recommen-
Fill gaps between windows, doors, trim,
                                                 dations set forth herein are subject to
and other through-wall openings with an
                                                 change and pertain to the product offered
appropriate caulk after priming the sur-
                                                 at the time of publication. Consult your
face.
                                                 Sherwin-Williams representative to obtain
                                                 the most recent Product Data Sheet.
                         Traffic                           SETFAST® ACRYLIC LATEX
                           &                                                    TRAFFIC MARKING PAINT
                          Zone
                        Products                                                                  TM2160
                                                                                                  TM2161
                                                                                                                                WHITE
                                                                                                                     LEAD FREE YELLOW

     Revised 9/09                                                                                                                   10.01

                      PRODUCT DESCRIPTION                                                    RECOMMENDED USES
SETFAST ACRYLIC LATEX TRAFFIC MARKING PAINT is a con-                    • For marking parking lots, curbs, and other areas when very fast
ventional dry (non-heated application) water based paint intended        dry times are not critical, and water based or low VOC coatings
for use in marking parking lots, airports, and roads. TM2160, and        are required or desired.
TM2161 conform to current VOC regulations, and may be used for
general applications where specific specification compliance is not        • Water based paints are required in areas with VOC regulations
required. The product dries to no pickup in less than 60 minutes         in effect and are recommended for asphalt surfaces less than one
when properly applied under most environmental conditions.               year old (see Surface Preparation for new asphalt).

•    Water clean up                                                      • Parking lots                   • Municipalities
•    Fast drying                                                         • Striping contractors           • Shopping centers
•    High visibility                                                     • Plant maintenance              • Streets and highways
•    Ready to use
•    Glass beads can be added for making reflective markings

                   PRODUCT CHARACTERISTICS                                           PERFORMANCE CHARACTERISTICS
Finish:                        Flat

Color:                         White, Yellow                              Test Name               Test Method         Results
                                                                          Bleed Resistance        ASTM D969           8 minimum
Volume Solids:                 50%, minimum                               Bleed Ratio             ASTM D969           0.96 minimum
                                                                                                  Fed. Std. 595       6 CIELAB maxi-
Weight Solids:                 70%, minimum                               Color (yellow)
                                                                                                  #33538              mum
                                                                          Dry No Pickup           ASTM D711           45 min. at 50% RH
VOC (EPA Method 24):           <100 g/L; 0.83 lb/gal
                                                                          Dry Opacity             Fed. Mtd. 141c @
                                                                                                                       0.92 minimum
                                                                          (Contrast Ratio)        5 mils wet
           Recommended Spreading Rate per coat:
                                                                          Flash Point             ASTM D3278           145°F (63°C)
    Approximately 320 lineal feet of standard 4" stripe per gallon
                                                                          Flexibility             ASTM D522            pass
                                         Minimum          Maximum         Fineness of Grind       ASTM D1210           3 Hegman min.
    Wet mils (microns)                  15.0 375                          Freeze-Thaw
    Dry mils (microns)                   7.5 188                                                  ASTM D2243           5 cycles minimum
                                                                          Stability
    ~Coverage sq ft/gal (m2/L)           110 2.7                          Reflectance
    Theoretical coverage sq ft/gal                                                                ASTM E97             84% minimum
    (m2/L) @ 1 mil / 25 microns dft      800 19.6                         (white only)
           NOTE: Brush or roll application for small areas only.                                                       400 cycles mini-
                                                                          Scrub Resistance        ASTM D2486
                                                                                                                       mum
    If the asphalt is insufficiently cured, applying a thin coat
    (approximately 1/2 the recommended dft) generally reduces the         Viscosity               ASTM D562            75 to 85 KU
    extent of lifting and cracking.                                       Volatile Organic        ASMT D3960           95 grams/liter; 0.79
                                                                          Compounds               excluding water      lbs/gallon
      Drying Schedule @ 15.0 mils wet (375 microns):
                               @ 77°F/25°C
                                50% RH
    To touch:                  60 minutes
    No traffic pickup after:    60 minutes
    Drying time is temperature, humidity, and film thickness dependent.                     COMPOSITION INFORMATION
    Shelf Life:                       12 months, unopened                Total Solids:                        50% minimum by volume
                                      Store indoors at 40°F (4.5°C) to                                        70% minimum by weight
                                      100°F (38°C)
    Flash Point:                      145°F (63°C), PMCC                 Pigment Weight Percent:              54% minimum
    Reducer/Clean Up:                 Water
                                                                         Vehicle Type:                        Acrylic Latex Polymer



                                                       www.sherwin-williams.com/protective                             continued on back
                          Traffic                                SETFAST® ACRYLIC LATEX
                            &                                                               TRAFFIC MARKING PAINT
                           Zone
                         Products                                                                                 TM2160
                                                                                                                  TM2161
                                                                                                                                                      WHITE
                                                                                                                                           LEAD FREE YELLOW

                                                        PRODUCT INFORMATION                                                                                      10.01

                     RECOMMENDED SYSTEMS                                                                   SURFACE PREPARATION

Cured Asphalt, Concrete, Brick, and other Surfaced                                 Surface must be clean, dry, and in sound condition. Remove all
Highways:                                                                          oil, dust, grease, dirt, loose rust, and other foreign material to
                                                                                   ensure adequate adhesion.
1 ct.      Setfast Acrylic Latex Traffic Marking Paint
           @ 15 mils (375 microns) wet, 7.5 mils (188 microns)                     Refer to product Application Bulletin for detailed surface prepara-
           dft, approximately 320 lineal feet of standard 4" stripe                tion information.
           per gallon
                                                                                   Minimum recommended surface preparation:
                                                                                     Concrete:                    Cured, clean, dry, sound
The systems listed above are representative of the product's use,                    Asphalt:                     Cured, clean, dry, sound
other systems may be appropriate.                                                    Brick:                       Cured, clean, dry, sound
                                                                                                            Surface Preparation Standards
                                                                                                         Condition of      ISO 8501-1    Swedish Std.
                                                                                                         Surface           BS7079:A1     SIS055900       SSPC    NACE
                                                                                   White Metal                             Sa 3          Sa 3            SP 5    1
                                                                                   Near White Metal                        Sa 2.5        Sa 2.5          SP 10   2
                                                                                   Commercial Blast                        Sa 2          Sa 2            SP 6    3
                                                                                   Brush-Off Blast                         Sa 1          Sa 1            SP 7    4
                                                                                   Hand Tool Cleaning Rusted Rusted
                                                                                                       Pitted &
                                                                                                                           C St 2
                                                                                                                           D St 2
                                                                                                                                         C St 2
                                                                                                                                         D St 2
                                                                                                                                                         SP 2
                                                                                                                                                         SP 2
                                                                                                                                                                 -
                                                                                                                                                                 -
                                                                                   Power Tool Cleaning Rusted Rusted
                                                                                                       Pitted &
                                                                                                                           C St 3
                                                                                                                           D St 3
                                                                                                                                         C St 3
                                                                                                                                         D St 3
                                                                                                                                                         SP 3
                                                                                                                                                         SP 3
                                                                                                                                                                 -
                                                                                                                                                                 -


                                                                                                                        TINTING
                                                                                   Do not tint.

                                                                                                         APPLICATION CONDITIONS
                                                                                   Temperature:                         50°F (10°C) minimum, 110°F (43°C)
                                                                                                                        maximum
                                                                                                                        (air, surface, and material)
                                                                                                                        At least 5°F (2.8°C) above dew point
                                                                                   Relative humidity:                   85% maximum

                                                                                   Refer to product Application Bulletin for detailed application information.

                                                                                                          ORDERING INFORMATION
                                                                                   Packaging:                           5 gallon (18.9L) containers

                                                                                   Weight:
                                                                                               White:                   13.04 ± 0.2 lbs/gal ; 1.56 Kg/L
                                                                                               Yellow:                  13.25 ± 0.2 lbs/gal ; 1.59 Kg/L

                                                                                                            SAFETY PRECAUTIONS
                                                                                   Refer to the MSDS sheet before use.

                                                                                   Published technical data and instructions are subject to change without notice.
                                                                                   Contact your Sherwin-Williams representative for additional technical data and
                                                                                   instructions.


                                                                                                                     WARRANTY
                                                                                   The Sherwin-Williams Company warrants our products to be free of manufactur-
                               DISCLAIMER                                          ing defects in accord with applicable Sherwin-Williams quality control procedures.
The information and recommendations set forth in this Product Data Sheet are       Liability for products proven defective, if any, is limited to replacement of the defec-
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        tive product or the refund of the purchase price paid for the defective product as
Such information and recommendations set forth herein are subject to change and    determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
pertain to the product offered at the time of publication. Consult your Sherwin-   OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
Williams representative to obtain the most recent Product Data Information and     STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
Application Bulletin.                                                              CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

                                                            www.sherwin-williams.com/protective
                        Traffic                                 SETFAST® ACRYLIC LATEX
                          &                                                          TRAFFIC MARKING PAINT
                         Zone
                       Products                                                                         TM2160
                                                                                                        TM2161
                                                                                                                                        WHITE
                                                                                                                             LEAD FREE YELLOW

  Revised 9/09                                        APPLICATION BULLETIN                                                                     10.01

                    SURFACE PREPARATIONS                                                         APPLICATION CONDITIONS
                                                                              Temperature:                  50°F (10°C) minimum, 110°F (43°C)
Surface must be clean, dry, and in sound condition. Remove all                                              maximum
oil, dust, grease, dirt, loose rust, and other foreign material to                                          (air, surface, and material)
ensure adequate adhesion.                                                                                   At least 5°F (2.8°C) above dew point

Surfaces should be clean, dry and free from loose or peeling paint.           Relative humidity:            85% maximum
Do not apply when air or surface temperatures are below 50°F
(10°C), or when the relative humidity exceeds 85%, or when the                                   APPLICATION EQUIPMENT
temperature falls below the dew point.
                                                                              The following is a guide. Changes in pressures and tip sizes may
The presence of concrete sealers or efflorescence on new concrete              be needed for proper spray characteristics. Always purge spray
may interfere with adhesion and should be removed by extended                 equipment before use with listed reducer. Any reduction must be
weathering, etching, or abrasive blasting.                                    compliant with existing VOC regulations and compatible with the
                                                                              existing environmental and application conditions.
Most previously painted lines may be repainted without additional
surface preparation, provided the old paint is still tightly adhered to       Reducer/Clean Up ...........Water
the surface. However, multiple layers of paint will eventually peel
and require removal.                                                          Airless Spray Line Striping Equipment
                                                                                Pressure.........................1800 - 2700 psi
New asphalt surfaces should ideally be allowed to age several                   Hose...............................1/4" - 3/8" ID
months before striping. Latex paint will not bleed on most asphalt              Tip ...................................015" - .019"
surfaces; however, shrinkage of the paint film during curing can                 Filter ...............................60 mesh
cause new asphalt to lift or crack. Exceeding the recommended                   Reduction .......................As needed up to 12½% by volume
film thickness will increase the tendency to cause asphalt lifting.
Placing an inconspicuous test stripe to determine if a new asphalt            Conventional Spray Line Striping Equipment
surface has cured sufficiently to paint is recommended.                         Gun ................................Binks 21 (Bleeder)
                                                                               Fluid Nozzle ...................#68
If it is necessary to paint new asphalt surfaces, do not exceed an             Air Nozzle.......................Internal mix, #709
application rate of 8 mils (200 microns) wet (approximately 200 sq             Atomization Pressure .....20 - 80 psi
ft/gal / 4.9 m2/L). Special care should be given to laps and edges             Fluid Pressure ................30 - 60 psi
of stencils to prevent excessive film thickness.                                Reduction .......................As needed up to 12½% by volume

                                                                              Brush, small areas only
                     Surface Preparation Standards
                   Condition of    ISO 8501-1   Swedish Std.                    Brush..............................Nylon/polyester
                   Surface         BS7079:A1    SIS055900      SSPC    NACE     Reduction .......................As needed up to 12½% by volume
White Metal                        Sa 3         Sa 3           SP 5    1
Near White Metal                   Sa 2.5       Sa 2.5         SP 10   2
Commercial Blast                   Sa 2         Sa 2           SP 6    3
Brush-Off Blast                    Sa 1         Sa 1           SP 7    4      Roller, small areas only
                    Rusted
Hand Tool Cleaning Pitted & Rusted C St 2
                                   D St 2
                                                C St 2
                                                D St 2
                                                               SP 2
                                                               SP 2
                                                                       -
                                                                       -       Cover .............................3/8" woven with solvent resistant core
Power Tool Cleaning Rusted Rusted C St 3
                    Pitted &       D St 3
                                                C St 3
                                                D St 3
                                                               SP 3
                                                               SP 3
                                                                       -
                                                                       -       Reduction .......................As needed up to 12½% by volume

                                                                              NOTE: Fluid and atomization pressures are dependent on environ-
                                                                              mental conditions. Use the lowest pressures necessary to achieve
                                                                              a "flat line".

                                                                              Although intended for spray application, small areas may be painted
                                                                              by brush or roller.

                                                                              If the striping machine is also used for solvent based paint, care
                                                                              must be taken to avoid solvent contamination.
                                                                              If specific application equipment is not listed above, equivalent
                                                                              equipment may be substituted.


                                                         www.sherwin-williams.com/protective                                     continued on back
                         Traffic                                SETFAST® ACRYLIC LATEX
                           &                                                                TRAFFIC MARKING PAINT
                          Zone
                        Products                                                                                 TM2160
                                                                                                                 TM2161
                                                                                                                                                    WHITE
                                                                                                                                         LEAD FREE YELLOW

                                                        APPLICATION BULLETIN                                                                                  10.01

                   APPLICATION PROCEDURES                                                                    PERFORMANCE TIPS
                                                                   Spreading rates are calculated on volume solids and do not include
Surface preparation must be completed as indicated.                an application loss factor due to surface profile, roughness or po-
                                                                   rosity of the surface, skill and technique of the applicator, method
Mixing Instructions: Mix paint thoroughly to a uniform consistency of application, various surface irregularities, material lost during
with low speed power agitation prior to use.                       mixing, spillage, overthinning, climatic conditions, and excessive
                                                                   film build.
Apply paint at the recommended film thickness and spreading
rate as indicated below:                                           Excessive reduction of material can affect film build, appearance,
                                                                   and adhesion.
          Recommended Spreading Rate per coat:
 Approximately 320 lineal feet of standard 4" stripe per gallon                    In order to avoid blockage of spray equipment, clean equipment
                                                                                   before use or before periods of extended downtime with water.
                                            Minimum            Maximum
 Wet mils (microns)                        15.0 375                                Asphalt surfaces generally require aging prior to painting.
 Dry mils (microns)                         7.5 188
                                                                                   If the asphalt is insufficiently cured, applying a thin coat (approxi-
 ~Coverage sq ft/gal (m2/L)                 110 2.7
                                                                                   mately 1/2 the recommended dft) generally reduces the extent of
 Theoretical coverage sq ft/gal
 (m2/L) @ 1 mil / 25 microns dft      800 19.6                                     lifting and cracking.
        NOTE: Brush or roll application for small areas only.                      Check adhesion by applying a test strip to determine the readiness
 If the asphalt is insufficiently cured, applying a thin coat                       for painting.
 (approximately 1/2 the recommended dft) generally reduces the
 extent of lifting and cracking.                                                   The coating may be made into reflective paint by dropping on glass
                                                                                   beads while the paint is still wet.
    Drying Schedule @ 15.0 mils wet (375 microns):
                                @ 77°F/25°C                                        Painted surfaces can become slippery when wet. Traffic paints are
                                 50% RH                                            not intended for use as floor paints, and should not be used to paint
                                                                                   large areas subject to pedestrian traffic. For instance, painting an
 To touch:                      60 minutes
                                                                                   entire traffic stall is not recommended.
 No traffic pickup after:        60 minutes
  Drying time is temperature, humidity, and film thickness dependent.               Do not paint on wet surfaces.

Application of coating above maximum or below minimum Do not paint when the relative humidity is above 85%.
recommended spreading rate may adversely affect coating
performance.
                                                        Do not paint when the temperature is below 50°F (10°C).

                                                                                   Cool, damp conditions will prolong the drying time.



                                                                                   Refer to Product Information sheet for additional performance
                                                                                   characteristics and properties.

                                                                                                           SAFETY PRECAUTIONS
                    CLEAN UP INSTRUCTIONS                                          Refer to the MSDS sheet before use.

Clean spills and spatters immediately with soap and warm water.                    Published technical data and instructions are subject to change without notice.
Clean hands and tools immediately after use with soap and warm                     Contact your Sherwin-Williams representative for additional technical data and
water. After cleaning, flush spray equipment with mineral spirits                   instructions.
to prevent rusting of the equipment. Follow manufacturer's safety
recommendations when using mineral spirits.
                                                                                                                    WARRANTY
                              DISCLAIMER                                           The Sherwin-Williams Company warrants our products to be free of manufacturing
                                                                                   defects in accord with applicable Sherwin-Williams quality control procedures.
The information and recommendations set forth in this Product Data Sheet are       Liability for products proven defective, if any, is limited to replacement of the de-
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        fective product or the refund of the purchase price paid for the defective product
Such information and recommendations set forth herein are subject to change and    as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
pertain to the product offered at the time of publication. Consult your Sherwin-   OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
Williams representative to obtain the most recent Product Data Information and     STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
Application Bulletin.                                                              CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

                                                           www.sherwin-williams.com/protective
                                                                                                                               108.21
                                                                                                  PREPRITE®
                                                                                              BONDING PRIMER
     As of 09/22/08, Complies with:
                                                                            INTERIOR/EXTERIOR
OTC
SCAQMD
CARB
              Yes LEED® CIv2.0
              Yes LEED® NCv2.2
              Yes LEED® CSv2.0
                                      Yes
                                      Yes
                                      Yes
                                                                   ADHESION PROMOTING PRIMER
MPI Spec #
NAHB
               17 LEED® H
              Yes
                                      Yes
                                                                                     B51W50
         CHARACTERISTICS                                     APPLICATION                               SURFACE PREPARATION

  PrepRite Bonding Primer - Adhesion            Apply at temperatures above 50°F                      WARNING! Removal of old paint by sand-
  Promoting Primer is a high quality,           No reduction necessary                                ing, scraping or other means may gener-
  waterborne, acrylic, primer. Designed for     Brush                                                 ate dust or fumes that contain lead. Expo-
  coating hard, slick, glossy surfaces with     Use a nylon/polyester brush                           sure to lead dust or fumes may cause brain
  minimal surface preparation.                  Roller                                                damage or other adverse health effects,
  Because of the exceptional adhesion of        Use a 3/8" - 3/4" synthetic roller cover              especially in children or pregnant women.
  this product, sanding may not be neces-       Spray—Airless                                         Controlling exposure to lead or other haz-
  sary for most clean, paintable surfaces.      Pressure ................................ 2400 psi    ardous substances requires the use of
  Sanding or dulling with an abrasive           Tip ................................. .017" - .019"   proper protective equipment, such as a
  cleaner is recommended on glossy, hard                                                              properly fitted respirator (NIOSH approved)
  surfaces for maximum adhesion.                Use on these surfaces:                                and proper containment and cleanup. For
  PrepRite Bonding Primer can be top-           Old, glossy paint                                     more information, call the National Lead
  coated with oil/alkyd, latex, epoxy, ure-     Galvanized Metal                                      Information Center at 1-800-424-LEAD (in
  thane, and lacquer topcoats.                  Aluminum                                              US) or contact your local health authority.
  This can be used on most interior sur-        Steel (for repaint)
  faces as well as many small, exterior, ar-    Copper                                                PrepRite Bonding Primer Exterior/Interior
  chitectural details such as hard, glossy,     Drywall (previously painted)                          Adhesion Promoting Primer is extremely
  prefinished doors or shutters.                Tile                                                  sensitive to hydrocarbon containing sol-
  Color:                               White    Glass                                                 vents such as mineral spirits. When
  Coverage:              350 - 400 sq ft/gal    Glazed Block                                          cleaning the surface use only a water-
                 @ 4 mils wet; 1.7 mils dry     Porcelain                                             based emulsifying detergent.
  Drying Time, @ 77°F, 50% RH:                  Formica
  Drying and recoat times are temperature,      PVC                                                   Remove all surface contamination by
  humidity and film thickness dependent.        Fiberglass                                            washing with an appropriate cleaner,
     Touch:                      40 minutes     Ceramic Tile                                          rinse thoroughly and allow to dry. Exist-
     Recoat:                         4 hours    Vinyl                                                 ing peeled or checked paint should be
  Finish:                                Flat   Plastic                                               scraped and sanded to a sound surface.
  Flash Point:                           N/A    Masonry (previously painted)                          Because of the exceptional adhesion of
  Tinting - For best color development, use     Concrete (previously painted)                         this product, sanding may not be neces-
  the recommended "P"-shade primer. If                                                                sary for most clean, paintable surfaces.
  desired, up to 4 oz per gallon of Blend-A-                                                          Sanding or dulling with an abrasive
  Color Toner can be used to approximate                   EXTERIOR USE                               cleaner is recommended on glossy, hard
  the topcoat color. Check color before use.                                                          surfaces for maximum adhesion. Stains
  Vehicle Type:                       Acrylic   PrepRite Bonding Primer is recom-                     from water, smoke, ink, pencil, grease,
                   B51W50                       mended for adhesion promotion on                      etc. should be sealed with the appropri-
  VOC:                   42 g/L; 0.35 lb/gal    small exterior architectural projects                 ate primer/sealer.
  Volume Solids:                  43% ± 2%      and details.
  Weight Solids:                  57% ± 2%
  Weight per Gallon:                  11.1 lb   When priming larger exterior surfaces
                                                where maximum adhesion is needed,
  Always check for compatibility and adhe-      use DTM Bonding Primer.
  sion to the surface with the new coating      DTM Bonding Primer is recommended
  by appying a test patch of 2 - 3 square       for siding, Butler™ Buildings, and
  feet. Allow to dry thoroughly for 1 week      Kynar™.
  before checking adhesion.

9/2008                                                  www.sherwin-williams.com                                               continued on back
108.21
PREPRITE®
BONDING PRIMER
INTERIOR/EXTERIOR
ADHESION PROMOTING PRIMER
B51W50
 SURFACE PREPARATION                             SURFACE PREPARATION                                           CAUTIONS
Aluminum, Copper, and Galvanized                Mildew                                       Not for use on floors.
Wash to remove any oil, grease, or other        Remove before painting by washing with       Do not use this product in areas fre-
surface contamination. All corrosion must       a solution of 1 part liquid bleach and 3     quently subjected to water, e.g.: in show-
be removed with sandpaper, steel wool,          parts water. Apply the solution and scrub    ers, on countertops, etc.
or other abrading method.                       the mildewed area. Allow the solution to     For large exterior surfaces such as sid-
                                                remain on the surface for 10 minutes.        ing, use DTM Bonding Primer.
Ceramic Tile/ Glazed Block and Brick/           Rinse thoroughly with water and allow the    Do not use on wood due to problems with
Porcelain                                       surface to dry before painting. Wear pro-    flexibility.
After removing all surface contamination,       tective eyewear, waterproof gloves, and
the surface should be scuff sanded or           protective clothing. Quickly wash off any                         LABEL CAUTIONS
                                                                                             CAUTION contains CRYSTALLINE SILICA. Use only
scrubbed with an abrasive cleaner to dull       of the mixture that comes in contact with    with adequate ventilation. To avoid overexposure,
the surface for best adhesion.                  your skin. Do not add detergents or am-      open windows and doors or use other means to
                                                monia to the bleach/water solution.          ensure fresh air entry during application and drying. If
Glass                                                                                        you experience eye watering, headaches, or dizzi-
                                                                                             ness, increase fresh air, or wear respiratory protection
Apply PrepRite Bonding Primer directly
to glass that has been thoroughly
                                                 CLEANUP INFORMATION                         (NIOSH approved) or leave the area. Adequate ven-
                                                                                             tilation required when sanding or abrading the dried
cleaned. CAUTION: Any opaque coat-                                                           film. If adequate ventilation cannot be provided wear
ing will block light, which then causes an      Clean spills and spatters immediately with   an approved particulate respirator (NIOSH approved).
                                                soap and warm water. Clean hands and         Follow respirator manufacturer’s directions for respi-
increase in the surface temperature of the                                                   rator use. Avoid contact with eyes and skin. Wash
glass. Dark colors will get hotter than light   tools immediately after use with soap and    hands after using. Keep container closed when not in
colors. In tightly fitted glass, any increase   warm water. After cleaning, flush spray      use. Do not transfer contents to other containers for
                                                equipment with mineral spirits to prevent    storage. FIRST AID: In case of eye contact, flush
in the temperature of the glass will cause                                                   thoroughly with large amounts of water. Get medical
some expansion of the glass, which may          rusting of the equipment. Follow manu-       attention if irritation persists. If swallowed, call Poison
cause it to shatter.                            facturers safety recommendations when        Control Center, hospital emergency room, or physi-
                                                using mineral spirits.                       cian immediately. DELAYED EFFECTS FROM LONG
                                                                                             TERM OVEREXPOSURE. Abrading or sanding of the
Plastic/Vinyl/PVC/Fiberglass/ Formica                                                        dry film may release crystalline silica which has been
After removing all surface contamination,                                                    shown to cause lung damage and cancer under long
the surface should be scuff sanded or                                                        term exposure. WARNING: This product contains
                                                                                             chemicals known to the State of California to cause
scrubbed with an abrasive cleaner to dull                                                    cancer and birth defects or other reproductive harm.
the surface for best adhesion.                                                               DO NOT TAKE INTERNALLY. KEEP OUT OF THE
                                                                                             REACH OF CHILDREN.
                                                                                             HOTW 09/22/2008                B51W00050          08 00
Steel
Rust and mill scale must be removed
using sandpaper, steel wool, or other
abrading method. Bare steel must be                                                          The information and recommendations
primed the same day as cleaned with a                                                        set forth in this Product Data Sheet are
rust-inhibiting primer. PrepRite Bonding                                                     based upon tests conducted by or on
Primer does not contain any rust inhibi-                                                     behalf of The Sherwin-Williams Com-
tors, do not use on bare steel.                                                              pany. Such information and recommen-
                                                                                             dations set forth herein are subject to
                                                                                             change and pertain to the product offered
                                                                                             at the time of publication. Consult your
                                                                                             Sherwin-Williams representative to obtain
                                                                                             the most recent Product Data Sheet.
                      Protective                                   DTM ACRYLIC COATING
                         &
                       Marine
                      Coatings                                                                      B66-100 SERIES
                                                                                                    B66-200 SERIES
                                                                                                                                      GLOSS
                                                                                                                               S EMI -G LOSS

     Revised 9/09                                                                                                                            1.25

                     PRODUCT DESCRIPTION                                                        RECOMMENDED USES
DTM ACRYLIC COATING is a 100% acrylic, water reducible, corro-           For use over prepared:
sion resistant coating for light to moderate industrial use. Designed    • Steel          • Galvanizing     • Wood
for new construction or maintenance use and can be used directly         • Aluminum       • Concrete        • Masonry
over prepared substrates.                                                • Drywall        • Zinc rich primers
                                                                         • Water treatment plants
•    Chemical resistant              • Corrosion resistant
                                                                         Examples:
•    Fast dry                        • Low odor, Low VOC
                                                                         • Buildings       • Equipment        • New Construction
•    Flash rust/early rust resistant                                     • Machinery       • Piping           • Select Marine Structures
•    Interior/exterior use                                               • Power plants • Structural Steel • Water treatment plants
•    Single component                                                    • Storage Tank Exteriors
•    Outstanding application characteristics                             • Suitable for use in USDA inspected facilities
                                                                         • Conforms to AWWA D102-03 OCS #3
                  PRODUCT CHARACTERISTICS                                • Acceptable for use in high performance architectural applications.
Finish:                        Gloss or Semi-Gloss                                     PERFORMANCE CHARACTERISTICS
Color:                         Wide range of colors including
                               safety colors                             Substrate*: Steel
Volume Solids:                 38% ± 2%, may vary by color               Surface Preparation*: SSPC-SP10
Weight Solids:                 50% ± 2%, may vary by color               System Tested*:
                                                                          1 ct. DTM Acrylic Coating @ 3.0 mils (75 microns)
VOC (EPA Method 24):           <250 g/L; 2.08 lb/gal                      *unless otherwise noted below


                                                                         Test Name                  Test Method              Results
           Recommended Spreading Rate per coat:                                                      ASTM D4060, CS17
                                                                         Abrasion
                                        Minimum          Maximum         Resistance
                                                                                                     wheel, 1000 cycles,     107 mg loss
    Wet mils (microns)                   6.5 (165)       10.0 (250)                                  1kg load
    Dry mils (microns)                   2.5 (63)         4.0 (100)      Accelerated                 ASTM D4587, QUV-A,
                                                                                                                             Passes
                                                                         Weathering                  5,000 hours
    ~Coverage sq ft/gal (m2/L)          155 (3.8)        250 (6.1)
    Theoretical coverage sq ft/gal                                       Adhesion                    ASTM D4541              >500 psi
    (m2/L) @ 1 mil / 25 microns dft     608 (14.9)                                                                           Rating 9 per ASTM
       NOTE: Brush or roll application may require multiple coats to     Corrosion                   ASTM D5894, 15          D610 for rusting ;
      achieve maximum film thickness and uniformity of appearance.        Weathering                  cycles, 5,040 hours     Rating10 per ASTM
                                                                                                                             D714 for blistering
       Drying Schedule @ 8.0 mils wet (200 microns):                     Direct Impact
                                                                                                     ASTM D2794              >160 in. lbs.
                      @ 50°F/10°C      @ 77°F/25°C      @ 110°F/43°C     Resistance
                                        50% RH                           Dry Heat Resistance         ASTM D2485              300°F (149°C)
    To touch:          1.5 hours          1 hour         30 minutes      Exterior Durability         1 year, 45° South       Excellent
    Tack free:          6 hours          4 hours          2 hours                                    ASTM D522, 180°
                                                                         Flexibility                                         Passes
    To recoat:          6 hours          4 hours          2 hours                                    bend, 1/8" mandrel
    To cure:            30 days          30 days          30 days        Moisture
                                                                                                     ASTM D4585, 100°F
    Drying time is temperature, humidity, and film thickness dependent.   Condensation                                        Passes
                                                                                                     (38°C), 300 hours
                                                                         Resistance (2 coats)
    Shelf Life:                       36 months, unopened
                                      Store indoors at 40°F (4.5°C) to   Pencil Hardness             ASTM D3363              2B
                                      100°F (38°C)                       Salt Fog Resistance         ASTM B117, 500 hours    Excellent
    Flash Point:                      >200°F (93°C), PMCC                                                                    Flame Spread
    Reducer/Clean Up:                 Water                              Flame Spread Rating         ASTM E84-91a            Index - 5 ; Smoke
                                                                                                                             Density Index - 0


                                                                         Provides performance comparable to products formulated to fed-
                                                                         eral specification: AA50570, and Paint Specification: SSPC-Paint
                                                                         23 and 24.


                                                       www.sherwin-williams.com/protective                                  continued on back
                       Protective                                          DTM ACRYLIC COATING
                          &
                        Marine
                       Coatings                                                                                   B66-100 SERIES
                                                                                                                  B66-200 SERIES
                                                                                                                                                          GLOSS
                                                                                                                                                     SEMI-GLOSS

                                                        PRODUCT INFORMATION                                                                                        1.25

                     RECOMMENDED SYSTEMS                                                                   SURFACE PREPARATION
                                                 Dry Film Thickness / ct.
                                                  Mils        (Microns)            Surface must be clean, dry, and in sound condition. Remove all
Steel:                                                                             oil, dust, grease, dirt, loose rust, and other foreign material to
                                                                                   ensure adequate adhesion.
1 ct.    DTM Acrylic Primer/Finish                2.5-5.0       (63-125)
 or      Kem Bond HS                              2.0-5.0       (63-125)           Do not use hydrocarbon solvents for cleaning.
 or      Zinc Clad Primer                         3.0-5.0       (75-125)           Refer to product Application Bulletin for detailed surface preparation in-
 or      ProCryl Primer                           2.0-4.0       (50-100)           formation.
2 cts.   DTM Acrylic Coating                      2.5-4.0       (63-100)           Minimum recommended surface preparation:
                                                                                   * Iron & Steel:               SSPC-SP2
Steel:                                                                                Aluminum:                  SSPC-SP1
                                                                                      Galvanizing:               SSPC-SP1
2 cts. DTM Acrylic Coating*                     2.5-4.0     (63-100)                  Concrete & Masonry:        SSPC-SP13/NACE6 or ICRI 03732, CSP 1-3
(Application of coating on unprimed bare steel may cause pinpoint rusting.)           Wood:                      Dry and sanded smooth. Primer required.
                                                                                   *Safety Colors, Deep Base, and Ultradeep colors require a prime coat
Aluminum:                                                                          of DTM Acrylic Primer/Finish, B66W1, for maximum durability, adhesion,
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)           and corrosion protection.
                                                                                                            Surface Preparation Standards
                                                                                                         Condition of      ISO 8501-1    Swedish Std.
Aluminum:                                                                                                Surface           BS7079:A1     SIS055900       SSPC    NACE
                                                                                   White Metal                             Sa 3          Sa 3            SP 5    1
1 ct. DTM Wash Primer                             0.7-1.3       (18-32)            Near White Metal                        Sa 2.5        Sa 2.5          SP 10   2
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)           Commercial Blast                        Sa 2          Sa 2            SP 6    3
                                                                                   Brush-Off Blast                         Sa 1          Sa 1            SP 7    4
                                                                                   Hand Tool Cleaning Rusted Rusted        C St 2        C St 2          SP 2    -
Galvanizing:                                                                                           Pitted &            D St 2        D St 2          SP 2    -
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)           Power Tool Cleaning Rusted Rusted
                                                                                                       Pitted &
                                                                                                                           C St 3
                                                                                                                           D St 3
                                                                                                                                         C St 3
                                                                                                                                         D St 3
                                                                                                                                                         SP 3
                                                                                                                                                         SP 3
                                                                                                                                                                 -
                                                                                                                                                                 -

Concrete Block:
1 ct. Heavy Duty Block Filler                     10.0-18.0     (250-450)                                               TINTING
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)           Tint with Blend-A-Color Toner or EnviroToner at 100% tint strength, using
                                                                                   the respective tinting formula pages. Better performance will be achieved
                                                                                   with EnviroToners. Five minutes minimum mixing on a mechanical shaker
Concrete/Masonry:                                                                  is required for complete mixing of color.
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)           Tinting with Blend-A-Color can affect the flash/early rust resistance of the
                                                                                   coating.
Drywall:
1 ct. PrepRite 200 Latex Primer                   1.0-1.5       (25-38)                                  APPLICATION CONDITIONS
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)
                                                                                   Temperature:                         50°F (10°C) minimum, 110°F (43°C) maxi-
Prefinished Siding: (Baked-on finishes)                                                                                   mum
                                                                                                                        (air, surface, and material)
1 ct. DTM Bonding Primer                          2.0-5.0       (50-125)                                                At least 5°F (2.8°C) above dew point
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)           Relative humidity:                   85% maximum

Wood, exterior:                                                                    Refer to product Application Bulletin for detailed application information.
1 ct. A-100 Exterior Oil Wood Primer              1.5           (38)
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)                                  ORDERING INFORMATION
Wood, interior:                                                                    Packaging:                           1 (3.78L) and 5 gallon (18.9L) containers
1 ct. PrepRite Wall & Wood Primer                 1.5           (38)               Weight:                              10.2 ± 0.2 lb/gl       1.22 Kg/L
2 cts. DTM Acrylic Coating                        2.5-4.0       (63-100)                                                May vary by color.
*Safety Colors, Deep Base, and Ultradeep colors require a prime coat of
DTM Acrylic Primer/Finish, B66W1, for maximum durability, adhesion, and                                     SAFETY PRECAUTIONS
corrosion protection.                                                              Refer to the MSDS sheet before use.

                                                                                   Published technical data and instructions are subject to change without notice.
                                                                                   Contact your Sherwin-Williams representative for additional technical data and
The systems listed above are representative of the product's use,
                                                                                   instructions.
other systems may be appropriate.
                                                                                                                     WARRANTY
                               DISCLAIMER                                          The Sherwin-Williams Company warrants our products to be free of manufactur-
The information and recommendations set forth in this Product Data Sheet are       ing defects in accord with applicable Sherwin-Williams quality control procedures.
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        Liability for products proven defective, if any, is limited to replacement of the defec-
Such information and recommendations set forth herein are subject to change and    tive product or the refund of the purchase price paid for the defective product as
pertain to the product offered at the time of publication. Consult your Sherwin-   determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
Williams representative to obtain the most recent Product Data Information and     OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
Application Bulletin.                                                              STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
                                                                                   CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
                                                            www.sherwin-williams.com/protective
                      Protective                                        DTM ACRYLIC COATING
                         &
                       Marine
                      Coatings                                                                          B66-100 SERIES
                                                                                                        B66-200 SERIES
                                                                                                                                             GLOSS
                                                                                                                                      S EMI -G LOSS

  Revised 9/09                                        APPLICATION BULLETIN                                                                      1.25

                    SURFACE PREPARATIONS                                                        APPLICATION CONDITIONS
                                                                             Temperature:                    50°F (10°C) minimum, 110°F (43°C)
Surface must be clean, dry, and in sound condition. Remove all                                               maximum
oil, dust, grease, dirt, loose rust, and other foreign material to                                           (air, surface, and material)
ensure adequate adhesion.                                                                                    At least 5°F (2.8°C) above dew point
Do not use hydrocarbon solvents for cleaning.
                                                                             Relative humidity:              85% maximum
Iron & Steel
Minimum surface preparation is Hand Tool Clean per SSPC-SP2.                                    APPLICATION EQUIPMENT
Remove all oil and grease from surface per SSPC-SP1. For better
performance, use Commercial Blast Cleaning per SSPC-SP6.                     The following is a guide. Changes in pressures and tip sizes may
                                                                             be needed for proper spray characteristics. Always purge spray
*Safety Colors, Deep Base, and Ultradeep colors require a prime
                                                                             equipment before use with listed reducer. Any reduction must be
coat of DTM Acrylic Primer/Finish, B66W1, for maximum durability,
                                                                             compliant with existing VOC regulations and compatible with the
adhesion, and corrosion protection.
                                                                             existing environmental and application conditions.
Aluminum
                                                                             Reducer/Clean Up ...........Water
Remove all oil and grease per SSPC-SP1. Self-priming.
                                                                             Airless Spray
Galvanizing
                                                                               Pressure.........................1500 psi
The surface should be weathered for 6 months prior to painting.
                                                                               Hose...............................1/4" ID
Remove all oil and grease per SSPC-SP1. Self-priming.
                                                                               Tip ...................................017" - .021"
                                                                               Filter ...............................60 mesh
Concrete and Masonry
                                                                               Reduction .......................As needed up to 12½% by volume
For surface preparation, refer to SSPC-SP13/NACE 6 or ICRI
03732, CSP 1-3. Surfaces should be thoroughly cleaned and dry.
                                                                             Conventional Spray
Surface temperatures must be at least 55°F (13°C) before filling.
                                                                              Gun ................................Binks 95
Use Heavy Duty Block Filler. Filler must be thoroughly dry before
                                                                              Fluid Nozzle ...................66
topcoating per manufacturer's recommendations.
                                                                              Air Nozzle.......................63PB
                                                                              Atomization Pressure .....50 psi
Wood
                                                                              Fluid Pressure ................15-20 psi
Surface must be clean, dry and sound. Prime with recommended
                                                                              Reduction .......................As needed up to 12½% by volume
primer. No painting should be done immediately after a rain or
during foggy weather. Knots and pitch streaks must be scraped,
                                                                             Brush
sanded and spot primed before full coat of primer is applied. All
                                                                               Brush..............................Nylon / polyester
nail holes or small openings must be properly caulked.
                                                                               Reduction .......................Not recommended
Previously Painted Surfaces
                                                                             Roller
If in sound condition, clean the surface of all foreign material.
                                                                              Cover .............................3/8" woven solvent resistant core
Smooth, hard or glossy coatings and surfaces should be dulled
                                                                              Reduction .......................Not recommended
by abrading the surface. Apply a test area, allowing paint to dry
one week before testing adhesion. If adhesion is poor, additional
abrasion of the surface and/or removal of the previous coating may
be necessary. Retest surface for adhesion. If paint is peeling or            If specific application equipment is not listed above, equivalent
badly weathered, clean surface to sound substrate and treat as a             equipment may be substituted.
new surface as above.

                     Surface Preparation Standards
                   Condition of    ISO 8501-1   Swedish Std.
                   Surface         BS7079:A1    SIS055900      SSPC   NACE
White Metal                        Sa 3         Sa 3           SP 5   1
Near White Metal                   Sa 2.5       Sa 2.5         SP10   2
Commercial Blast                   Sa 2         Sa 2           SP 6   3
Brush-Off Blast                    Sa 1         Sa 1           SP 7   4
                    Rusted
Hand Tool Cleaning Pitted & Rusted C St 2
                                   D St 2
                                                C St 2
                                                D St 2
                                                               SP 2
                                                               SP 2
                                                                      -
                                                                      -
Power Tool Cleaning Rusted Rusted C St 3
                    Pitted &       D St 3
                                                C St 3
                                                D St 3
                                                               SP 3
                                                               SP 3
                                                                      -
                                                                      -

                                                         www.sherwin-williams.com/protective                                      continued on back
                       Protective                                         DTM ACRYLIC COATING
                          &
                        Marine
                       Coatings                                                                                  B66-100 SERIES
                                                                                                                 B66-200 SERIES
                                                                                                                                                        GLOSS
                                                                                                                                                   SEMI-GLOSS

                                                        APPLICATION BULLETIN                                                                                    1.25

                   APPLICATION PROCEDURES                                                                    PERFORMANCE TIPS
                                                                                   Stripe coat all crevices, welds, and sharp angles to prevent early failure
Surface preparation must be completed as indicated.                                in these areas.
Mixing Instructions: Mix paint thoroughly to a uniform consistency When using spray application, use a 50% overlap with each pass of the
with low speed power agitation prior to use.                       gun to avoid holidays, bare areas, and pinholes. If necessary, cross spray
                                                                                   at a right angle
Apply paint at the recommended film thickness and spreading
rate as indicated below:                                   During the early stages of drying, the coating is sensitive to rain, dew, high
                                                                                   humidity, and moisture condensation. Plan painting schedules to avoid
          Recommended Spreading Rate per coat:                                     these influences during the first 16-24 hours of curing.
                                            Minimum            Maximum
                                                                                   Spreading rates are calculated on volume solids and do not include an
 Wet mils (microns)                          6.5 (165)         10.0 (250)          application loss factor due to surface profile, roughness or porosity of the
 Dry mils (microns)                          2.5 (63)           4.0 (100)          surface, skill and technique of the applicator, method of application, various
 ~Coverage sq ft/gal (m2/L)                 155 (3.8)          250 (6.1)           surface irregularities, material lost during mixing, spillage, overthinning,
 Theoretical coverage sq ft/gal                                                    climatic conditions, and excessive film build.
 (m2/L) @ 1 mil / 25 microns dft     608 (14.9)
                                                                                   Excessive reduction of material can affect film build, appearance, and
    NOTE: Brush or roll application may require multiple coats to                  adhesion.
   achieve maximum film thickness and uniformity of appearance.
                                                                                   Safety Colors, Deep Base, and Ultradeep colors require a prime coat of
     Drying Schedule @ 8.0 mils wet (200 microns):                                 DTM Acrylic Primer/Finish, B66W1, for maximum durability, adhesion, and
                       @ 50°F/10°C        @ 77°F/25°C        @ 110°F/43°C          corrosion protection.
                                           50% RH
                                                                                   Application temperature above 95°F (35°C) may cause dry spray, uneven
 To touch:              1.5 hours             1 hour           30 minutes          sheen, and poor adhesion.
 Tack free:              6 hours             4 hours            2 hours
 To recoat:              6 hours             4 hours            2 hours            Application temperature below 50°F (10°C) may cause poor adhesion and
 To cure:                30 days             30 days            30 days            lengthen the drying and curing time.
  Drying time is temperature, humidity, and film thickness dependent.
                                                                                   DTM Acrylic Coating is extremely sensitive to hydrocarbon containing sol-
                                                                                   vents. When cleaning the surface per SSPC-SP1, use only an emulsifying
Application of coating above maximum or below minimum industrial detergent followed by a water rinse.
recommended spreading rate may adversely affect coating
performance.
                                                                                   Do not use hydrocarbon solvents for cleaning.




                                                                                   Refer to Product Information sheet for additional performance
                                                                                   characteristics and properties.

                                                                                                           SAFETY PRECAUTIONS
                    CLEAN UP INSTRUCTIONS                                          Refer to the MSDS sheet before use.
Clean spills and spatters immediately with soap and warm water.
Clean hands and tools immediately after use with soap and warm                     Published technical data and instructions are subject to change without notice.
water. After cleaning, flush spray equipment with Mineral Spirits                   Contact your Sherwin-Williams representative for additional technical data and
to prevent rusting of the equipment. Follow manufacturer's safety                  instructions.
recommendations when using Mineral Spirits.
                                                                                                                    WARRANTY
                              DISCLAIMER                                           The Sherwin-Williams Company warrants our products to be free of manufacturing
The information and recommendations set forth in this Product Data Sheet are       defects in accord with applicable Sherwin-Williams quality control procedures.
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        Liability for products proven defective, if any, is limited to replacement of the de-
Such information and recommendations set forth herein are subject to change and    fective product or the refund of the purchase price paid for the defective product
pertain to the product offered at the time of publication. Consult your Sherwin-   as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
Williams representative to obtain the most recent Product Data Information and     OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
Application Bulletin.                                                              STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
                                                                                   CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
                                                           www.sherwin-williams.com/protective
                                                                                                                     101.40

                                                                                              PROMAR® 200
     As of 07/22/09, Complies with:                                               INTERIOR LATEX GLOSS
OTC           Yes LEED® CIv2.0        Yes
SCAQMD
CARB
               No LEED® NCv2.2
              Yes LEED® CSv2.0
                                      Yes
                                      Yes                                             B21W200 SERIES
MPI Spec #     54 LEED® H             Yes
NAHB          Yes


          CHARACTERISTICS                                   SPECIFICATIONS                      SURFACE PREPARATION
 ProMar 200 Interior Latex Gloss is our              Block                                     WARNING! Removal of old paint by sand-
 Professional Best quality product. This             1 ct. Loxon Block Surfacer                ing, scraping or other means may gener-
 product is recommended for interior                 2 cts. ProMar 200 Interior Latex Gloss    ate dust or fumes that contain lead. Expo-
 application on walls and trim of primed                                                       sure to lead dust or fumes may cause brain
 plaster, wallboard, wood, masonry, and              Drywall                                   damage or other adverse health effects,
 primed metal.                                       1 ct. ProMar 200 Latex Primer             especially in children or pregnant women.
                                                     2 cts. ProMar 200 Interior Latex Gloss    Controlling exposure to lead or other haz-
 Color:                                Most colors                                             ardous substances requires the use of
 To optimize hide and color developement,            Plaster                                   proper protective equipment, such as a
 always use the reccommended P-Shade primer          1 ct. Premium Wall & Wood Primer          properly fitted respirator (NIOSH approved)
 Coverage:          350 - 400 sq ft/gal                     Primer                             and proper containment and cleanup. For
              @ 4 mils wet; 1.5 mils dry             2 cts. ProMar 200 Interior Latex Gloss    more information, call the National Lead
 Drying Time, @ 77°F, 50% RH:                                                                  Information Center at 1-800-424-LEAD (in
   Touch:                        1 hour              Masonry                                   US) or contact your local health authority.
   Recoat:                      4 hours              1 ct. Loxon Concrete & Masonry Primer
 Drying and recoat times are temperature,            2 cts. ProMar 200 Interior Latex Gloss    Remove all surface contamination by
 humidity, and film thickness dependent                                                        washing with an appropriate cleaner,
 Finish:              60-80 units @ 60°              Wood                                      rinse thoroughly and allow to dry. Exist-
 Flash Point:                        N/A             1 ct. Premium Wall & Wood Primer          ing peeled or checked paint should be
 Tinting with Blend-A-Color:                                Primer                             scraped and sanded to a sound surface.
 Base            oz/gal        Strength              2 cts. ProMar 200 Interior Latex Gloss    Glossy surfaces should be sanded dull.
 Extra White       0-5             100%                                                        Stains from water, smoke, ink, pencil,
 Deep Base        4-12             100%                                                        grease, etc. should be sealed with the
 Luminous Base 0-5                 125%                                                        appropriate primer/sealer.
 Vehicle Type:              Vinyl Acrylic
              B21W00251                                                                        Drywall
 VOC (less exempt solvents):                                                                   Fill cracks and holes with patching paste/
                     148 g/L; 1.23 lb/gal                                                      spackle and sand smooth. Joint com-
 Volume Solids:                 37 ± 2%                                                        pounds must be cured and sanded
 Weight Solids:                 46 ± 2%                                                        smooth. Remove all sanding dust.
 Weight per Gallon:                9.8 lb
                                                                                               Masonry, Concrete, Cement, Block
                                                                                               All new surfaces must be cured accord-
                                                                                               ing to the supplier’s recommendations—
                                                                                               usually about 30 days. Remove all form
                                                                                               release and curing agents. Rough sur-
                                                                                               faces can be filled to provide a smooth
                                                                                               surface. If painting cannot wait 30 days,
                                                                                               allow the surface to cure 7 days and prime
                                                                                               the surface with Loxon Concrete & Ma-
                                                                                               sonry Primer.




12/2009                                                    www.sherwin-williams.com                                     continued on back
101.40

PROMAR® 200
INTERIOR LATEX GLOSS
B21W200 SERIES

 SURFACE PREPARATION                                         APPLICATION                                                CAUTIONS
Plaster                                         Apply at temperatures above 50°F.                     For interior use only.
Bare plaster must be cured and hard.            No reduction needed.                                  Protect from freezing.
Textured, soft, porous, or powdery plas-        Brush                                                 Non-photochemically reactive.
ter should be treated with a solution of 1      Use a nylon/polyester brush.
pint household vinegar to 1 gallon of wa-                                                                                  LABEL CAUTIONS
                                                Roller
ter. Repeat until the surface is hard, rinse                                                          CAUTION contains CRYSTALLINE SILICA. Use only
with clear water and allow to dry.              Use a 1/4" - 3/4" nap synthetic cover.                with adequate ventilation. To avoid overexposure,
                                                Spray—Airless                                         open windows and doors or use other means to
                                                                                                      ensure fresh air entry during application and drying. If
Wood                                            Pressure ................................ 2000 psi    you experience eye watering, headaches, or dizzi-
Sand any exposed wood to a fresh sur-           Tip ................................... .017"-.021"   ness, increase fresh air, or wear respiratory protection
                                                                                                      (NIOSH approved) or leave the area. Adequate ven-
face. Patch all holes and imperfections                                                               tilation required when sanding or abrading the dried
with a wood filler or putty and sand              CLEANUP INFORMATION                                 film. If adequate ventilation cannot be provided wear
smooth.                                                                                               an approved particulate respirator (NIOSH approved).
                                                                                                      Follow respirator manufacturer’s directions for respi-
                                                Clean spills and spatters immediately with            rator use. Avoid contact with eyes and skin. Wash
Mildew                                          soap and warm water. Clean hands and                  hands after using. Keep container closed when not in
Remove before painting by washing with          tools immediately after use with soap and             use. Do not transfer contents to other containers for
a solution of 1 part liquid bleach and 3                                                              storage. FIRST AID: In case of eye contact, flush
                                                warm water. After cleaning, flush spray               thoroughly with large amounts of water. Get medical
parts water. Apply the solution and scrub       equipment with mineral spirits to prevent             attention if irritation persists. If swallowed, call Poison
the mildewed area. Allow the solution to        rusting of the equipment. Follow                      Control Center, hospital emergency room, or physi-
remain on the surface for 10 minutes.           manufacturer's safety recommendations                 cian immediately. DELAYED EFFECTS FROM LONG
Rinse thoroughly with water and allow the                                                             TERM OVEREXPOSURE. Abrading or sanding of the
                                                when using mineral spirits.                           dry film may release crystalline silica which has been
surface to dry before painting. Wear pro-                                                             shown to cause lung damage and cancer under long
tective eyewear, waterproof gloves, and                                                               term exposure. WARNING: This product contains
protective clothing. Quickly wash off any                                                             chemicals known to the State of California to cause
                                                                                                      cancer and birth defects or other reproductive harm.
of the mixture that comes in contact with                                                             DO NOT TAKE INTERNALLY. KEEP OUT OF THE
your skin. Do not add detergents or am-                                                               REACH OF CHILDREN.
monia to the bleach/water solution.                                                                   HOTW           07/22/2009           B21W00251        13 00


Caulking
Gaps between walls, ceilings, crown
moldings, and other interior trim can be
filled with the appropriate caulk after prim-
ing the surface.

                                                                                                      The information and recommendations
                                                                                                      set forth in this Product Data Sheet are
                                                                                                      based upon tests conducted by or on
                                                                                                      behalf of The Sherwin-Williams Company.
                                                                                                      Such information and recommendations
                                                                                                      set forth herein are subject to change and
                                                                                                      pertain to the product offered at the time
                                                                                                      of publication. Consult your Sherwin-Wil-
                                                                                                      liams representative to obtain the most
                                                                                                      recent Product Data Sheet.
                                                                                                                       101.37
                                                                                  PROGREEN 200™
                                                                                       LOW VOC
      As of 09/22/08, Complies with:                                   INTERIOR LATEX SEMI-GLOSS
OTC             Yes LEED® CIv2.0 Yes
SCAQMD
CARB
                Yes LEED® NCv2.2Yes
                Yes LEED® CSv2.0 Yes                                             B31-600 SERIES
MPI Spec # 43, 52, 54 LEED® H       Yes
NAHB            Yes


         CHARACTERISTICS                                    SPECIFICATIONS                     SURFACE PREPARATION
  ProGreen 200 Low Odor Interior Latex             Block                                      WARNING! Removal of old paint by sand-
  Semi-Gloss is a durable, professional            1 ct. Loxon Block Surfacer                 ing, scraping or other means may gener-
  quality, interior vinyl acrylic finish, formu-   2 cts. ProGreen 200 Low VOC Interior       ate dust or fumes that contain lead. Expo-
  lated without silica, for use on walls, ceil-           Latex Semi-Gloss                    sure to lead dust or fumes may cause brain
  ings, and trim of primed plaster, wall-                                                     damage or other adverse health effects,
  board, wood, masonry, and primed                 Drywall                                    especially in children or pregnant women.
  metal.                                           1 ct. ProGreen 200 Low VOC Interior        Controlling exposure to lead or other haz-
  You can use this product, without typical               Latex Primer                        ardous substances requires the use of
  odor complaints, in occupied areas be-           2 cts. ProGreen 200 Low VOC Interior       proper protective equipment, such as a
  cause of the very low odor during appli-                Latex Semi-Gloss                    properly fitted respirator (NIOSH approved)
  cation and drying.                                                                          and proper containment and cleanup. For
                                                   Plaster                                    more information, call the National Lead
  Color:                    most colors            1 ct. Premium Wall & Wood Primer           Information Center at 1-800-424-LEAD (in
  Coverage:          350 - 400 sq ft/gal           2 cts. ProGreen 200 Low VOC Interior       US) or contact your local health authority.
              @ 4 mils wet; 1.6 mils dry                  Latex Semi-Gloss
  Drying Time, @ 77°F, 50% RH:                                                                Remove all surface contamination by
  Drying and recoat times are temperature,         Masonry                                    washing with an appropriate cleaner,
  humidity, and film thickness dependent.          1 ct. Loxon Concrete & Masonry Primer      rinse thoroughly and allow to dry. Scrape
    Touch:                           1 hour        2 cts. ProGreen 200 Low VOC Interior       and sand peeled or checked paint to a
    Recoat:                        4 hours                Latex Semi-Gloss                    sound surface. Sand glossy surfaces
  Finish:               25-35 units @ 60°                                                     dull. Seal stains from water, smoke, ink,
  Flash Point:                          N/A        Wood                                       pencil, grease, etc. with the appropriate
  Tinting with Blend-A-Color:                      1 ct. Premium Wall & Wood Primer           primer/sealer.
  Base             oz/gal        Strength          2 cts. ProGreen 200 Low VOC Interior
  Extra White        0-5             100%                 Latex Semi-Gloss                    Drywall
  Deep Base         4-12             100%                                                     Fill cracks and holes with patching paste/
  Vehicle Type:                Vinyl Acrylic       1 ct.    Premium Wall & Wood Primer        spackle and sand smooth. Joint com-
                B31W00651                          1 ct.    Loxon Concrete & Masonry Primer   pounds must be cured and sanded
  VOC (less exempt solvents):                      1 ct.    Loxon Block Surfacer              smooth. Remove all sanding dust.
                        46 g/L; 0.39 lb/gal        1 ct.    Pro Industrial Pro-Cryl Primer
  Volume Solids:                  42 ± 2%          1 ct.    ProMar 200 Latex Primer           Masonry, Concrete, Cement, Block
  Water Vapor Permeance                                                                       All new surfaces must be cured accord-
    ASTM E96 A                  4.4 perms                                                     ing to the supplier’s recommendations—
  Weight Solids:                  53 ± 2%                                                     usually about 30 days. Remove all form
  Weight per Gallon:                10.3 lb                                                   release and curing agents. Rough sur-
                                                                                              faces can be filled to provide a smooth
                                                                                              surface. If painting cannot wait 30 days,
                                                                                              allow the surface to cure 7 days and prime
                                                                                              the surface with Loxon Concrete & Ma-
                                                                                              sonry Primer.




12/2009                                                    www.sherwin-williams.com                                    continued on back
101.37
PROGREEN 200™
LOW VOC
INTERIOR LATEX SEMI-GLOSS
B31-600 SERIES

 SURFACE PREPARATION                                        APPLICATION                                               CAUTIONS
Plaster                                        Apply at temperatures above 50°F.                     For interior use only.
Bare plaster must be cured and hard.           No reduction needed.                                  Protect from freezing.
Textured, soft, porous, or powdery plas-       Brush                                                 Non-photochemically reactive.
ter should be treated with a solution of 1     Use a nylon/polyester brush.
pint household vinegar to 1 gallon of wa-      Roller                                                                 LABEL CAUTIONS
                                                                                                     Use only with adequate ventilation. To avoid overex-
ter. Repeat until the surface is hard, rinse   Use a 1/4" - 3/4" nap synthetic cover.                posure, open windows and doors or use other means
with clear water and allow to dry.             Spray—Airless                                         to ensure fresh air entry during application and drying.
                                               Pressure .............................. 2000 psi      If you experience eye watering, headaches, or dizzi-
Wood                                           Tip ................................... .017"-.021"   ness, increase fresh air, or wear respiratory protection
                                                                                                     (NIOSH approved) or leave the area. Avoid contact
Sand any exposed wood to a fresh sur-                                                                with eyes and skin. Wash hands after using. Keep
face. Patch all holes and imperfections          CLEANUP INFORMATION                                 container closed when not in use. Do not transfer
with a wood filler or putty and sand                                                                 contents to other containers for storage. FIRST AID:
                                                                                                     In case of eye contact, flush thoroughly with large
smooth.                                        Clean spills, spatters, hands and tools               amounts of water. Get medical attention if irritation
                                               immediately after use with soap and warm              persists. If swallowed, call Poison Control Center,
Mildew                                         water. After cleaning, flush spray equip-             hospital emergency room, or physician immediately.
Remove before painting by washing with                                                               WARNING: This product contains chemicals known
                                               ment with mineral spirits to prevent rust-            to the State of California to cause cancer and birth
a solution of 1 part liquid bleach and 3       ing of the equipment. Follow                          defects or other reproductive harm. DO NOT TAKE
parts water. Apply the solution and scrub      manufacturer’s safety recommendations                 INTERNALLY. KEEP OUT OF THE REACH OF
the mildewed area. Allow the solution to                                                             CHILDREN.
                                               when using mineral spirits.                           HOTW 09/22/2008              B31W00651          04 00
remain on the surface for 10 minutes.
Rinse thoroughly with water and allow the
surface to dry before painting. Wear pro-
tective eyewear, waterproof gloves, and
protective clothing. Quickly wash off any
of the mixture that comes in contact with
your skin. Do not add detergents or am-
monia to the bleach/water solution.

Caulking
Gaps between walls, ceilings, crown
moldings, and other interior trim can be
filled with the appropriate caulk after
priming the surface.

                                                                                                     The information and recommendations
                                                                                                     set forth in this Product Data Sheet are
                                                                                                     based upon tests conducted by or on
                                                                                                     behalf of The Sherwin-Williams Com-
                                                                                                     pany. Such information and recommen-
                                                                                                     dations set forth herein are subject to
                                                                                                     change and pertain to the product offered
                                                                                                     at the time of publication. Consult your
                                                                                                     Sherwin-Williams representative to ob-
                                                                                                     tain the most recent Product Data Sheet.
                      Protective                                   WATERBORNE ACRYLIC
                         &                                                   DRY FALL
                       Marine                                                                        B42W1             FLAT WHITE
                                                                                                     B42T1  CLEAR TINT BASE (FLAT)
                      Coatings                                                                       B42W2
                                                                                                     B42BW3
                                                                                                                   EG-SHEL WHITE
                                                                                                                       FLAT BLACK

     Revised 9/09                                                                                                                          3.01

                     PRODUCT DESCRIPTION                                                         RECOMMENDED USES
WATERBORNE ACRYLIC DRY FALL is a water based, high light                   For use over prepared interior ceilings, walls, and structural steel
reflective white coating (black also available) that falls dry in ten       in environments such as:
feet. Fallout can be swept up for easy cleanup of work area.
                                                                           •   Warehouses
•    High hiding                    •   Ten foot dry fallout               •   Industrial, commercial, and institutional buildings
•    Increases lighting efficiency   •   Easy cleanup                       •   Textile mills
•    High light reflectance          •   Low odor                           •   Manufacturing facilities
•    Flash rust resistance          •   Interior use                       •   Gymnasiums
                                                                           •   Suitable for use in USDA inspected facilities
                                                                           •   Acceptable for use in high performance architectural applications.

                   PRODUCT CHARACTERISTICS                                               PERFORMANCE CHARACTERISTICS
Finish:                        Flat or Eg-Shel                             • The bright, full-hiding, brilliant white shade of Waterborne Acrylic
                                                                             Dry Fall increases an area's lighting efficiency, which promotes
Color:                         Flat White, Eg-Shel White, Flat Black         safety and reduces eye strain due to dimly lit work stations. It
                               a wide range of colors available              helps improve employee productivity through better work area
                                                                             lighting due to its high light reflectance.
Volume Solids:                 41% ± 2%
                                                                           • The fast drying modified acrylic resin of this waterborne coating
(White)
                                                                             reduces the propensity to rust, bleed, and freckle when applied
Weight Solids:                 58% ± 2%                                      over small bare steel areas, previous coating nicks, and slight
(White)                                                                      rust.
VOC (calculated):              <100g/L; 0.83 lb/gal
                                                                           • The ten foot dry fallout characteristic reduces cleanup because
           Recommended Spreading Rate per coat:                              its overspray dust can be swept up, thereby limiting the extent
                                          Minimum          Maximum           of masking equipment and floor areas. Waterborne Acrylic Dry
                                                                             Fall dusts less than conventional alkyd dry fall products. This
    Wet mils (microns)                     7.0 175         11.0 275          helps diminish the nuisance from overspray on the applicator
    Dry mils (microns)                     3.0 75           4.5 112          and the amount of waste and dust to be cleaned up.
    ~Coverage sq ft/gal (m2/L)            135 3.3          225 5.5
    Theoretical coverage sq ft/gal                                         • Light Reflectance Value of the White is 83 ± 3%
    (m2/L) @ 1 mil / 25 microns dft     656 16.1
                                                                             Light Reflectance Value of the Black is 5 ± 3%
       NOTE: Brush or roll application may require multiple coats to
      achieve maximum film thickness and uniformity of appearance.
                                                                           Substrate*: Cold Rolled Steel
       Drying Schedule @ 7.0 mils wet (175 microns):                       Surface Preparation*: SSPC-SP1
                      @ 55°F/13°C        @ 77°F/25°C     @ 110°F/43°C      System Tested*:
                                          50% RH                            1 ct: Waterborne Acrylic Dryfall Flat @ 4.5 mils (112 microns) dft
    To touch:         45 minutes         30 minutes       20 minutes       *unless otherwise noted below
    To handle:          1 hour           45 minutes       30 minutes
    To recoat:         2 hours             1 hour           1 hour         Test Name                 Test Method             Results
    To cure:            2 days            4 hours          3 hours                                   ASTM D4060 CS10
    Dry fallout:      10-20 feet           10 feet          10 feet        Abrasion                                          122 mg loss
                                                                                                     wheel, 1000 cycles,
    Drying time is temperature, humidity, and film thickness dependent.     Resistance                                        (average)
                                                                                                     500 g load
    Shelf Life:                         36 months, unopened                Adhesion
                                                                                                      ASTM D4541             408 psi
                                        Store indoors at 40°F (4.5°C) to   (blasted steel)
                                        100°F (38°C).                                                 ASTM D522, 180°
    Flash Point:                        499°F (260°C), PMCC                Flexibility                                       Passes
                                                                                                      bend, 1/8" mandrel
    Reducer/Clean Up:
    Above 80°F (27°C):                  Water                                                                                Direct: 80 in. lbs.;
                                                                           Impact Resistance          ASTM D2794
    Below 80°F (27°C):                  60% denatured alcohol / 40%                                                          Reverse: 40 in. lbs.
                                        water




                                                       www.sherwin-williams.com/protective                                  continued on back
                       Protective                                        WATERBORNE ACRYLIC
                          &                                                        DRY FALL
                        Marine                                                                                   B42W1             FLAT WHITE
                                                                                                                 B42T1  CLEAR TINT BASE (FLAT)
                       Coatings                                                                                  B42W2
                                                                                                                 B42BW3
                                                                                                                               EG-SHEL WHITE
                                                                                                                                   FLAT BLACK

                                                        PRODUCT INFORMATION                                                                                        3.01

                     RECOMMENDED SYSTEMS                                                                   SURFACE PREPARATION
                                               Dry Film Thickness / ct.            Surface must be clean, dry, and in sound condition. Remove all
                                                  Mils       (Microns)             oil, dust, grease, dirt, loose rust, and other foreign material to
Steel, alkyd primer:                                                               ensure adequate adhesion.
1 ct.    Kem Bond HS                               2.0-5.0*     (50-125)           Refer to product Application Bulletin for detailed surface prepara-
                                                                                   tion information.
1-2 cts. Waterborne Acrylic Dry Fall               3.0-4.5      (75-112)
                                                                                   Do not use hydrocarbon solvents for cleaning.
Steel & Rusted Galvanized, acrylic primer:                                         Minimum recommended surface preparation:
1 ct.    DTM Acrylic Primer/Finish    2.5-5.0                   (63-125)           * Iron & Steel:       SSPC-SP2
                                                                                     Aluminum:           SSPC-SP1
1-2 cts. Waterborne Acrylic Dry Fall  3.0-4.5                   (75-112)             Galvanizing:        SSPC-SP1
                                                                                     Concrete & Masonry: SSPC-SP13/NACE 6, or ICRI
                                                                                                         03732, CSP1-3
Aluminum:                                                                          * Wood:               Clean, smooth, dust free
1-2 cts. Waterborne Acrylic Dry Fall               3.0-4.5      (75-112)             Previously Painted  SSPC-SP1
                                                                                   * Primer required
Galvanized Metal:                                                                                           Surface Preparation Standards
                                                                                                         Condition of      ISO 8501-1    Swedish Std.
1-2 cts. Waterborne Acrylic Dry Fall               3.0-4.5      (75-112)                                 Surface           BS7079:A1     SIS055900       SSPC    NACE
                                                                                   White Metal                             Sa 3          Sa 3            SP 5    1
                                                                                   Near White Metal                        Sa 2.5        Sa 2.5          SP 10   2
                                                                                   Commercial Blast                        Sa 2          Sa 2            SP 6    3
Concrete Block:                                                                    Brush-Off Blast                         Sa 1          Sa 1            SP 7    4
1 ct.    Heavy Duty Block Filler                   10.0-15.0 (250-375)             Hand Tool Cleaning Rusted Rusted
                                                                                                       Pitted &
                                                                                                                           C St 2
                                                                                                                           D St 2
                                                                                                                                         C St 2
                                                                                                                                         D St 2
                                                                                                                                                         SP 2
                                                                                                                                                         SP 2
                                                                                                                                                                 -
                                                                                                                                                                 -
1-2 cts. Waterborne Acrylic Dry Fall               3.0-4.5   (75-112)              Power Tool Cleaning Rusted Rusted
                                                                                                       Pitted &
                                                                                                                           C St 3
                                                                                                                           D St 3
                                                                                                                                         C St 3
                                                                                                                                         D St 3
                                                                                                                                                         SP 3
                                                                                                                                                         SP 3
                                                                                                                                                                 -
                                                                                                                                                                 -

Poured Concrete Walls, Interior:                                                                                        TINTING
1-2 cts. Waterborne Acrylic Dry Fall               3.0-4.5      (75-112)
                                                                                   Tint with EnviroToner Colorants only. White may be tinted with up
                                                                                   to 4 oz. per gallon. Clear Base may be tinted with up to 12 oz. per
Plaster and Wood, Interior:                                                        gallon. Five minutes minimum mixing on a mechanical shaker is
1 ct.    PrepRite Wall & Wood Primer               1.5-2.0      (40-50)            required for complete mixing of color.
1-2 cts. Waterborne Acrylic Dry Fall               3.0-4.5      (75-112)           Not controlled for tint strength.

Drywall:                                                                                                 APPLICATION CONDITIONS
1-2 cts. Waterborne Acrylic Dry Fall               3.0-4.5      (75-112)
                                                                                   Temperature:                         50°F (10°C) minimum, 110°F (43°C)
Previously Painted:                                                                                                     maximum
                                                                                                                        (air, surface, and material)
1-2 cts. Waterborne Acrylic Dry Fall               3.0-4.5      (75-112)                                                At least 5°F (2.8°C) above dew point
                                                                                   Relative humidity:                   75% maximum
                                                                                   Refer to product Application Bulletin for detailed application information.
*Steel Spec FD primers also acceptable.
                                                                                                          ORDERING INFORMATION
The systems listed above are representative of the product's use,                  Packaging:                           5 gallon (18.9L) containers
other systems may be appropriate.                                                  Weight:                              11.58 ± 0.2 lb, 1.4 Kg/L
                                                                                                                        may vary with color

                                                                                                            SAFETY PRECAUTIONS
                                                                                   Refer to the MSDS sheet before use.
                                                                                   Published technical data and instructions are subject to change without notice.
                                                                                   Contact your Sherwin-Williams representative for additional technical data and
                                                                                   instructions.

                               DISCLAIMER                                                                            WARRANTY
The information and recommendations set forth in this Product Data Sheet are       The Sherwin-Williams Company warrants our products to be free of manufactur-
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        ing defects in accord with applicable Sherwin-Williams quality control procedures.
                                                                                   Liability for products proven defective, if any, is limited to replacement of the defec-
Such information and recommendations set forth herein are subject to change and    tive product or the refund of the purchase price paid for the defective product as
pertain to the product offered at the time of publication. Consult your Sherwin-   determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
Williams representative to obtain the most recent Product Data Information and     OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
                                                                                   STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
Application Bulletin.                                                              CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

                                                             www.sherwin-williams.com/protective
                      Protective                                         WATERBORNE ACRYLIC
                         &                                                         DRY FALL
                       Marine                                                                           B42W1             FLAT WHITE
                                                                                                        B42T1  CLEAR TINT BASE (FLAT)
                      Coatings                                                                          B42W2
                                                                                                        B42BW3
                                                                                                                      EG-SHEL WHITE
                                                                                                                          FLAT BLACK

  Revised 9/09                                         APPLICATION BULLETIN                                                                   3.01

                    SURFACE PREPARATIONS                                                          APPLICATION CONDITIONS

Surface must be clean, dry, and in sound condition. Remove all                 Temperature:                  50°F (10oC) minimum, 110°F (43°C)
oil, dust, grease, dirt, loose rust, and other foreign material to                                           maximum
                                                                                                             (air, surface, and material)
ensure adequate adhesion.
                                                                                                             At least 5°F (2.8°C) above dew point
Do not use hydrocarbon solvents for cleaning.
                                                                               Relative humidity:            75% maximum
Iron & Steel
Minimum surface preparation is Hand Tool Clean per SSPC-SP2.                   NOTE: Dryfall characteristics will be adversely affected at tem-
Remove all oil and grease from surface by Solvent Cleaning per                 peratures below 77°F (25°C) or above 50% relative humidity.
SSPC-SP1. For better performance, use Commercial Blast Clean-
ing per SSPC-SP6/NACE 3, blast clean all surfaces using a sharp,                                  APPLICATION EQUIPMENT
angular abrasive for optimum surface profile (2 mils / 50 microns).
Prime any bare steel within 8 hours or before flash rusting occurs.             The following is a guide. Changes in pressures and tip sizes may
Primer required.
                                                                               be needed for proper spray characteristics. Always purge spray
Aluminum
                                                                               equipment before use with listed reducer. Any reduction must be
Remove all oil, grease, dirt, oxide and other foreign material by
Solvent Cleaning per SSPC-SP1.                                                 compliant with existing VOC regulations and compatible with the
Galvanized Steel                                                               existing environmental and application conditions.
Remove all oil, grease, dirt, oxide and other foreign material by Sol-
vent Cleaning per SSPC-SP1. When the surface has been treated                  Reducer/Clean Up:
with chromates or silicates, first Solvent Clean per SSPC-SP1 and                 Above 80°F (27°C) .........Water
apply a test patch. Allow paint to dry at least one week before test-            Below 80°F (27°C) .........60% denatured alcohol / 40% water
ing adhesion. If adhesion is poor, brush blasting per SSPC-SP7 is              Airless Spray
necessary to remove these treatments. Rusty galvanizing requires                 Pressure.........................2800
a minimum of Hand Tool Cleaning per SSPC-SP2, prime the area                     Hose...............................1/4" ID
the same day as cleaned.                                                         Tip ...................................017"-.019"
Concrete and Masonry                                                             Filter ...............................60 mesh
For surface preparation, refer to SSPC-SP13/NACE 6, or ICRI
                                                                                 Reduction .......................Not recommended
03732, CSP 1-3. Remove all loose mortar and foreign material.
Surface must be free of laitance, concrete dust, dirt, form release
agents, moisture curing membranes, loose cement and hardeners.                 Conventional Spray
Concrete and mortar must be cured at least 28 days @ 75°F (24°C).               Gun ................................Binks 95
On tilt-up and poured-in-place concrete, commercial detergents and              Fluid Nozzle ...................63C
abrasive blasting may be necessary. Fill bug holes, air pockets and             Air Nozzle.......................63PB
other voids with ArmorSeal Crack Filler. Primer required.                       Atomization Pressure .....60 psi
Brick must be allowed to weather for one year prior to surface                  Fluid Pressure ................50 psi
preparation and painting.                                                       Reduction .......................As needed up to 10% by volume
Drywall
Must be clean and dry. All nail heads must be set and spackled.                Brush
Joints must be taped and covered with joint compound. Spackled                   Brush..............................Not recommended
nail heads and tape joints must be sanded smooth and all dust
removed prior to the application of paint.
                                                                               Roller
Wood
Surface must be clean, dry and sound. Prime with recommended                    Cover .............................Not recommended
primer and paint as soon as possible. Knots and pitch streaks must
be scraped, sanded and spot primed before full coat of primer is ap-
plied. All nail holes or small openings must be properly caulked.              If specific application equipment is not listed above, equivalent
                                                                               equipment may be substituted.
                     Surface Preparation Standards
                   Condition of     ISO 8501-1   Swedish Std.
                   Surface          BS7079:A1    SIS055900      SSPC    NACE
White Metal                         Sa 3         Sa 3           SP 5    1
Near White Metal                    Sa 2.5       Sa 2.5         SP 10   2
Commercial Blast                    Sa 2         Sa 2           SP 6    3
Brush-Off Blast                     Sa 1         Sa 1           SP 7    4
Hand Tool Cleaning Rusted Rusted
                    Pitted &
                                    C St 2
                                    D St 2
                                                 C St 2
                                                 D St 2
                                                                SP 2
                                                                SP 2
                                                                        -
                                                                        -
Power Tool Cleaning Rusted Rusted
                    Pitted &
                                    C St 3
                                    D St 3
                                                 C St 3
                                                 D St 3
                                                                SP 3
                                                                SP 3
                                                                        -
                                                                        -
                                                          www.sherwin-williams.com/protective                                     continued on back
                       Protective                                        WATERBORNE ACRYLIC
                          &                                                        DRY FALL
                        Marine                                                                                   B42W1             FLAT WHITE
                                                                                                                 B42T1  CLEAR TINT BASE (FLAT)
                       Coatings                                                                                  B42W2
                                                                                                                 B42BW3
                                                                                                                               EG-SHEL WHITE
                                                                                                                                   FLAT BLACK

                                                        APPLICATION BULLETIN                                                                                    3.01

                   APPLICATION PROCEDURES                                                                    PERFORMANCE TIPS
                                                                                   When using spray application, use a 50% overlap with each pass
Surface preparation must be completed as indicated.                                of the gun to avoid holidays, bare areas, and pinholes. If necessary,
                                                                                   cross spray at a right angle.
Mixing Instructions: Mix paint thoroughly to a uniform consistency
with low speed power agitation prior to use.                       During the early stages of drying, the coating is sensitive to rain,
                                                                   dew, high humidity and moisture condensation. Plan painting
Apply paint at the recommended film thickness and spreading schedules to avoid these influences during the first 16-24 hours
rate as indicated below:
                                                                   of curing.
          Recommended Spreading Rate per coat:                                     Spreading rates are calculated on volume solids and do not include
                                            Minimum            Maximum             an application loss factor due to surface profile, roughness, or po-
 Wet mils (microns)                          7.0 175           11.0 275            rosity of the surface, skill, and technique of the applicator, method
 Dry mils (microns)                          3.0 75             4.5 112            of application, various surface irregularities, material lost during
 ~Coverage sq ft/gal (m2/L)                 135 3.3            225 5.5             mixing, spillage, overthinning, climatic conditions, and excessive
 Theoretical coverage sq ft/gal
                                                                                   film build.
 (m2/L) @ 1 mil / 25 microns dft     656 16.1
    NOTE: Brush or roll application may require multiple coats to
                                                                                   Reduction will have an adverse effect on the dryfall and flash rust
   achieve maximum film thickness and uniformity of appearance.                     characteristics of this coating.

     Drying Schedule @ 7.0 mils wet (175 microns):                                 Dryfall characteristics will be adversely affected at temperatures
                                                                                   below 77°F (25°C) or above 50% relative humidity.
                       @ 55°F/13°C        @ 77°F/25°C        @ 110°F/43°C
                                           50% RH
                                                                                   In order to avoid blockage of spray equipment, clean equipment
 To touch:             45 minutes          30 minutes          20 minutes          before use or before periods of extended downtime with water.
 To handle:              1 hour            45 minutes          30 minutes
 To recoat:             2 hours              1 hour              1 hour            Overspray landing on hot surfaces may adhere to these surfaces.
 To cure:                2 days             4 hours             3 hours            Immediately remove overspray from hot surfaces before adhe-
 Dry fallout:          10-20 feet            10 feet             10 feet           sion occurs. Note that surface temperatures can be higher than
  Drying time is temperature, humidity, and film thickness dependent.               air temperature.

                                                                                   Use EnviroToner Colorants only at the recommended levels.
Application of coating above maximum or below minimum
recommended spreading rate may adversely affect coating
performance.




                                                                                   Refer to Product Information sheet for additional performance
                                                                                   characteristics and properties.

                    CLEAN UP INSTRUCTIONS                                                                  SAFETY PRECAUTIONS
Clean spills and spatters immediately with soap and warm                           Refer to the MSDS sheet before use.
water. Clean tools immediately after use with soap and
warm water. After cleaning, flush spray equipment with Min-                         Published technical data and instructions are subject to change without notice.
eral Spirits, R1K4, to prevent rusting of equipment. Follow                        Contact your Sherwin-Williams representative for additional technical data and
manufacturer's safety recommendations when using any                               instructions.
solvent.
                                                                                                                    WARRANTY
                              DISCLAIMER                                           The Sherwin-Williams Company warrants our products to be free of manufacturing
The information and recommendations set forth in this Product Data Sheet are       defects in accord with applicable Sherwin-Williams quality control procedures.
based upon tests conducted by or on behalf of The Sherwin-Williams Company.        Liability for products proven defective, if any, is limited to replacement of the de-
Such information and recommendations set forth herein are subject to change and    fective product or the refund of the purchase price paid for the defective product
pertain to the product offered at the time of publication. Consult your Sherwin-   as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
Williams representative to obtain the most recent Product Data Information and     OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
Application Bulletin.                                                              STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
                                                                                   CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

                                                           www.sherwin-williams.com/protective
                                                                                                                                 107.10
                                  MASONRY                                                                    PREPRITE®
                                   COATING SYSTEMS
                                    OATING YSTEMS


                                                                                                           BLOCK FILLER
                          Concrete Solutions. Solid Results.




OTC
    As of 09/22/08, Complies with:
             Yes LEED® CIv2.0 Yes
                                                                                INTERIOR/EXTERIOR LATEX
SCAQMD       Yes LEED® NCv2.2Yes
CARB
MPI Spec #
             Yes LEED® CSv2.0 Yes
               4 LEED® H          Yes
                                                                                              B25W25
NAHB         Yes


        CHARACTERISTICS                                       APPLICATION                                   SURFACE PREPARATION

 • Allows topcoat on concrete block to          Masonry, Concrete, Cement, Block                           WARNING! Removal of old paint by sand-
                                                1 ct. PrepRite Block Filler                                ing, scraping or other means may gener-
   be smooth and uniform
                                                2 cts. Appropriate topcoat                                 ate dust or fumes that contain lead. Expo-
 • Effective on above-grade, unpainted                                                                     sure to lead dust or fumes may cause
   masonry surfaces                             Recommended Architectural Topcoats                         brain damage or other adverse health ef-
 Use on unpainted:                              A-100 Exterior Latex                                       fects, especially in children or pregnant
 • Masonry                                      Loxon Masonry Coating                                      women. Controlling exposure to lead or
 • Concrete                                     SuperPaint Exterior                                        other hazardous substances requires the
                                                Duration Exterior                                          use of proper protective equipment, such
 • Cement
                                                                                                           as a properly fitted respirator (NIOSH ap-
 • Flat Surfaced Concrete Block                 Classic 99 Interior                                        proved) and proper containment and
                                                Duration Home                                              cleanup. For more information, call the
 Color:                         Off White       ProClassic Interior                                        National Lead Information Center at 1-
 Coverage:               75-125 sq ft/gal       ProMar Interior                                            800-424-LEAD (in US) or contact your lo-
               @ 16 mils wet; 8 mils dry        SuperPaint Interior                                        cal health authority.
 Drying Time, @ 77°F, 50% RH:
                                                Recommended Industrial Topcoats                            Masonry, Concrete, Cement, Block
 temperature and humidity dependent             DTM Acrylic Enamel                                         Remove all surface contamination, form
   Touch:                         2 hours       Industrial Enamel                                          release agents, moisture curing mem-
   Recoat with latex based:     18 hours        Metalatex Semi-Gloss                                       branes, etc. by washing with an appro-
   Recoat with solvent based: 48 hours          Water Based Catalyzed Epoxy                                priate cleaner, rinse and allow to dry.
 Flash Point:                          N/A                                                                 Pressure wash the surface if needed.
                                                Apply at temperatures above 50°F.                          Remove existing peeled or checked
 Finish:                  0-5 units @ 85°
                                                No reduction necessary.                                    paint to a sound surface. Concrete and
 Vehicle Type:                Vinyl Acrylic                                                                mortar must be cured, generally 30 days,
              B25W00025                                                                                    at 75°F before painting.
                                                Brush - Use a nylon/polyester brush.
 VOC (less exempt solvents):
                                                Roller - Use a 3/8" to 1-1/2" nap cover.
                      45 g/L; 0.37 lb/gal                                                                  Complete removal of sealers, release
                                                Spray - Airless
 Volume Solids:                  48 ± 2%                                                                   compounds, and to provide a profile, tilt-
                                                Pressure .............................. 2300 psi           up and poured-in-place concrete could
 Weight Solids:                  68 ± 2%        Tip .............................................. .028"   require sandblasting or cleaning with
 Weight per Gallon:                13.5 lb      Reduction ... as needed up to 1 pt/gal                     commercial detergents. Do not apply to
                                                Remove all in-line and gun filters                         smooth, slick surfaces, peeling may
                                                                                                           result.
 PrepRite Block Filler meets or exceeds         Spray application may be backrolled to
 the criteria set forth by the U. S. Green      work material into the surface. All appli-                 Masonry surfaces must be dry before
 Building Council LEED-CI, Version 2.0                                                                     priming. Moisture content must be 15%
                                                cation methods may be squeegeed to
 and LEED-NC Version 2.2.                                                                                  or lower, and the pH between 6 and 9. If
                                                provide a very smooth surface.
 All results have been verified by our ISO                                                                 the pH is greater than 9, use Loxon Block
 9001 Laboratory.                                                                                          Surfacer in place of PrepRite Block Filler.

                                                                                                           For repairing exterior cracks, bugholes,
                                                                                                           air pockets, and other voids use
                                                                                                           ConSeal™ Patches and Sealants.


 9/2008                                                 www.sherwin-williams.com                                                     continued on back
107.10
PREPRITE®
BLOCK FILLER
INTERIOR/EXTERIOR LATEX
B25W25
  SURFACE PREPARATION                                        CAUTIONS
Mildew                                      Do not apply at temperatures below 50°F.
Remove before painting by washing with      Protect from freezing.
a solution of 1 part liquid bleach and 3
parts water. Apply the solution and scrub                        LABEL CAUTIONS
the mildewed area. Allow the solution to    CAUTION contains CRYSTALLINE SILICA. Use
                                            only with adequate ventilation. To avoid overexpo-
remain on the surface for 10 minutes.       sure, open windows and doors or use other means to
Rinse thoroughly with water and allow       ensure fresh air entry during application and drying.
the surface to dry before painting. Wear    If you experience eye watering, headaches, or dizzi-
protective eyewear, waterproof gloves,      ness, increase fresh air, or wear respiratory protection
                                            (NIOSH approved) or leave the area. Adequate
and protective clothing. Quickly wash off   ventilation required when sanding or abrading the dried
any of the mixture that comes in contact    film. If adequate ventilation cannot be provided wear
with your skin. Do not add detergents or    an approved particulate respirator (NIOSH approved).
                                            Follow respirator manufacturer’s directions for respi-
ammonia to the bleach/water solution.       rator use. Avoid contact with eyes and skin. Wash
                                            hands after using. Keep container closed when not in
                                            use. Do not transfer contents to other containers for
 CLEANUP INFORMATION                        storage. FIRST AID: In case of eye contact, flush
                                            thoroughly with large amounts of water. Get medical
Clean spills and spatters immediately       attention if irritation persists. If swallowed, call Poison
                                            Control Center, hospital emergency room, or physi-
with soap and warm water. Clean hands       cian immediately. DELAYED EFFECTS FROM LONG
and tools immediately after use with        TERM OVEREXPOSURE. Abrading or sanding of the
soap and warm water. After cleaning,        dry film may release crystalline silica which has been
                                            shown to cause lung damage and cancer under long
flush spray equipment with mineral spir-    term exposure. WARNING: This product contains
its to prevent rusting of the equipment.    chemicals known to the State of California to cause
Follow manufacturer's safety recom-         cancer and birth defects or other reproductive harm.
mendations when using mineral spirits.      DO NOT TAKE INTERNALLY. KEEP OUT OF THE
                                            REACH OF CHILDREN.
                                            HOTW        09/22/2008         B25W00025           25 00




                                            The information and recommendations
                                            set forth in this Product Data Sheet are
                                            based upon tests conducted by or on
                                            behalf of The Sherwin-Williams Com-
                                            pany. Such information and recommen-
                                            dations set forth herein are subject to
                                            change and pertain to the product offered
                                            at the time of publication. Consult your
                                            Sherwin-Williams representative to ob-
                                            tain the most recent Product Data Sheet.
                                                                                                                                 108.22
                                                                                        PROGREEN 200™
                                                                                                    LOW VOC
     As of 09/22/08, Complies with:                                                     INTERIOR LATEX PRIMER
OTC           Yes LEED® CIv2.0        Yes
SCAQMD
CARB
              Yes LEED® NCv2.2
              Yes LEED® SCv2.0
                                      Yes
                                      Yes                                                          B28W600
MPI Spec #     50 LEED® H             Yes
NAHB          Yes


         CHARACTERISTICS                                  SPECIFICATIONS                                 SURFACE PREPARATION
  ProGreen 200 Low Odor Interior Latex           This primer has been designed for use                  WARNING! Removal of old paint by sand-
  Primer is a durable, professional quality,     with the ProGreen 200 Interior Latex                   ing, scraping or other means may gener-
  interior vinyl acrylic primer for use on       topcoats providing a complete low odor/                ate dust or fumes that contain lead. Expo-
  walls and ceilings of plaster, wallboard,      low VOC system.                                        sure to lead dust or fumes may cause brain
  and masonry.                                   If desired, you can topcoat with any                   damage or other adverse health effects,
  You can use this product, without typical      Sherwin-Williams interior latex or oil                 especially in children or pregnant women.
  odor complaints, in occupied areas be-         architectural topcoat.                                 Controlling exposure to lead or other haz-
  cause of the very low odor during appli-                                                              ardous substances requires the use of
  cation and drying.                                         APPLICATION                                proper protective equipment, such as a
                                                                                                        properly fitted respirator (NIOSH approved)
  ProGreen 200 Low Odor Interior Latex           Use at temperatures above 50°F.                        and proper containment and cleanup. For
  Primer meets or exceeds the criteria set       No reduction necessary.                                more information, call the National Lead
  forth by the U. S. Green Building Council      Brush - Use a nylon/polyester brush.                   Information Center at 1-800-424-LEAD (in
  LEED-CI, Version 2.0 and LEED-NC Ver-          Roller - Use a 3/8" - 3/4" nap synthetic               US) or contact your local health authority.
  sion2.2. All results have been verified by     cover.
  our ISO 9001 Laboratory                        Spray - Airless                                        Remove all surface contamination by
                                                 Pressure ................................ 2000 psi     washing with an appropriate cleaner, rinse
  Color:                                White    Tip .................................... .017"-.021"   thoroughly and allow to dry. Existing
  Coverage:              350 - 400 sq ft/gal                                                            peeled or checked paint should be
                 @ 4 mils wet; 1.5 mils dry                                                             scraped and sanded to a sound surface.
  Drying Time, @ 77°F, 50% RH:
                                                   CLEANUP INFORMATION                                  Glossy surfaces should be sanded dull.
  Drying and recoat times are temperature,                                                              Stains from water, smoke, ink, pencil,
  humidity and film thickness dependent.         Clean spills and spatters immediately with             grease, etc. should be sealed with the
    Touch:                             1 hour    soap and warm water. Clean hands and                   appropriate primer/sealer.
    Recoat:                           4 hours    tools immediately after use with soap and
  Flash Point:                            N/A    warm water. Flush spray equipment after                Drywall
  Finish:                  0 - 5 units @ 85°     cleaning with mineral spirits to prevent               Fill cracks and holes with patching paste/
  Vehicle Type:                 Vinyl Acrylic    rusting of the equipment. Follow                       spackle and sand smooth. Joint com-
                 B28W00600                       manufacturer's safety recommendations                  pounds must be cured and sanded
  VOC (EPA Method 24):                           when using mineral spirits.                            smooth. Remove all sanding dust.
                          43 g/L; 0.36 lb/gal
  Volume Solids:                     39 ± 2%                                                            Masonry, Concrete, Cement, Block
  Water Vapor Permeance                                                                                 All new surfaces must be cured accord-
    ASTM E96 A                    3.9 perms                                                             ing to the supplier’s recommendations—
  Weight Solids:                     59 ± 2%                                                            usually about 30 days. Remove all form
  Weight per Gallon:                   12.4 lb                                                          release and curing agents. Masonry sur-
  Tinting - For best color development, use                                                             faces must be dry before priming. Mois-
  the recommended "P"-shade primer. If                                                                  ture content must be 15% or lower and
  desired, up to 4 oz per gallon of Blend-A-                                                            the pH between 5 and 9.
  Color Toner can be used to approximate                                                                Rough surfaces can be filled to provide a
  the topcoat color. Check color before use.                                                            smooth surface. If painting cannot wait 30
  Addition of Blend-A-Color Toner may in-                                                               days, allow the surface to cure 7 days and
  crease the VOC.                                                                                       prime the surface with PrepRite® Ma-
                                                                                                        sonry Primer.


9/2008                                                   www.sherwin-williams.com                                                continued on back
108.22
PROGREEN 200™
LOW VOC
INTERIOR LATEX PRIMER
B28W600

  SURFACE PREPARATION                                              CAUTIONS
 Plaster                                         For interior use only.
 Bare plaster must be cured and hard.            Protect from freezing.
 Textured, soft, porous, or powdery plas-        Non-photochemically reactive.
 ter should be treated with a solution of 1
 pint household vinegar to 1 gallon of                                    CAUTIONS
                                                 CAUTION contains CRYSTALLINE SILICA. Use only
 water. Repeat until the surface is hard,        with adequate ventilation. To avoid overexposure,
 rinse with clear water and allow to dry.        open windows and doors or use other means to
                                                 ensure fresh air entry during application and drying. If
 Mildew                                          you experience eye watering, headaches, or dizzi-
                                                 ness, increase fresh air, or wear respiratory protection
 Remove before painting by washing with          (NIOSH approved) or leave the area. Adequate ven-
 a solution of 1 part liquid bleach and 3        tilation required when sanding or abrading the dried
 parts water. Apply the solution and scrub       film. If adequate ventilation cannot be provided wear
                                                 an approved particulate respirator (NIOSH approved).
 the mildewed area. Allow the solution to        Follow respirator manufacturer’s directions for respi-
 remain on the surface for 10 minutes.           rator use. Avoid contact with eyes and skin. Wash
 Rinse thoroughly with water and allow the       hands after using. Keep container closed when not in
 surface to dry before painting. Wear pro-       use. Do not transfer contents to other containers for
                                                 storage. FIRST AID: In case of eye contact, flush
 tective eyewear, waterproof gloves, and         thoroughly with large amounts of water. Get medical
 protective clothing. Quickly wash off any       attention if irritation persists. If swallowed, call Poison
 of the mixture that comes in contact with       Control Center, hospital emergency room, or physi-
                                                 cian immediately. DELAYED EFFECTS FROM LONG
 your skin. Do not add detergents or am-         TERM OVEREXPOSURE. Abrading or sanding of the
 monia to the bleach/water solution.             dry film may release crystalline silica which has been
                                                 shown to cause lung damage and cancer under long
 Caulking                                        term exposure. WARNING: This product contains
                                                 chemicals known to the State of California to cause
 Gaps between walls, ceilings, crown             cancer and birth defects or other reproductive harm.
 moldings, and other interior trim can be        DO NOT TAKE INTERNALLY. KEEP OUT OF THE
 filled with the appropriate caulk after prim-   REACH OF CHILDREN.
                                                 HOTW 09/22/2008                B28W00600          05 00
 ing the surface.




                                                 The information and recommendations
                                                 set forth in this Product Data Sheet are
                                                 based upon tests conducted by or on
                                                 behalf of The Sherwin-Williams Com-
                                                 pany. Such information and recommen-
                                                 dations set forth herein are subject to
                                                 change and pertain to the product offered
                                                 at the time of publication. Consult your
                                                 Sherwin-Williams representative to obtain
                                                 the most recent Product Data Sheet.
                                                                                                                  101.26
                                                                             PROGREEN 200™
                                                                                      LOW VOC
    As of 09/22/08, Complies with:                                       INTERIOR LATEX EG-SHEL
OTC          Yes LEED® CIv2.0 Yes
SCAQMD
CARB
             Yes LEED® NCv2.2Yes
             Yes LEED® CSv2.0 Yes                                               B20-600 SERIES
MPI Spec #    52 LEED® H          Yes
NAHB         Yes


          CHARACTERISTICS                              SPECIFICATIONS                     SURFACE PREPARATION
 ProGreen 200 Low VOC Interior Latex             Block                                   WARNING! Removal of old paint by sand-
 Eg-Shel is a durable, professional qual-        1 ct. Loxon Block Surfacer              ing, scraping or other means may gener-
 ity, interior vinyl acrylic finish for use on   2 cts. ProGreen 200 Low VOC Interior    ate dust or fumes that contain lead. Expo-
 walls, ceilings, and trim of primed plas-              Latex Eg-Shel                    sure to lead dust or fumes may cause brain
 ter, wallboard, wood, masonry, and                                                      damage or other adverse health effects,
 primed metal.                                   Drywall                                 especially in children or pregnant women.
 You can use this product, without typical       1 ct. ProGreen 200 Low VOC Interior     Controlling exposure to lead or other haz-
 odor complaints, in occupied areas be-                 Latex Primer                     ardous substances requires the use of
 cause of the very low odor during appli-        2 cts. ProGreen 200 Low VOC Interior    proper protective equipment, such as a
 cation and drying.                                     Latex Eg-Shel                    properly fitted respirator (NIOSH approved)
                                                                                         and proper containment and cleanup. For
 Color:                      most colors         Masonry                                 more information, call the National Lead
 Coverage:            350 - 400 sq ft/gal        1 ct. Loxon Concrete & Masonry Primer   Information Center at 1-800-424-LEAD (in
               @ 4 mils wet; 1.7 mils dry        2 cts. ProGreen 200 Low VOC Interior    US) or contact your local health authority.
 Drying Time, @ 77°F, 50% RH:                           Latex Eg-Shel
 temperature and humidity dependent                                                      Remove all surface contamination by
   Touch:                           1 hour       Plaster                                 washing with an appropriate cleaner,
   Recoat:                        4 hours        1 ct. Premium Wall & Wood Primer        rinse thoroughly and allow to dry. Exist-
 Finish:               15-20 units @ 85°         2 cts. ProGreen 200 Low VOC Interior    ing peeled or checked paint should be
 Flash Point:                          N/A              Latex Eg-Shel                    scraped and sanded to a sound surface.
 Tinting with Blend-A-Color:                                                             Glossy surfaces should be sanded dull.
 Base             oz/gal        Strength         Wood                                    Stains from water, smoke, ink, pencil,
 Extra White        0-5             125%         1 ct. Premium Wall & Wood Primer        grease, etc. should be sealed with the
 Deep Base         4-12             100%         2 cts. ProGreen 200 Low VOC Interior    appropriate primer/sealer.
 Vehicle Type:                Vinyl Acrylic             Latex Eg-Shel
               B20W00651                                                                 Drywall
 VOC (less exempt solvents):                                                             Fill cracks and holes with patching paste/
                       40 g/L; 0.34 lb/gal                                               spackle and sand smooth. Joint com-
 Volume Solids:                  43 ± 2%                                                 pounds must be cured and sanded
 Water Vapor Permeance                                                                   smooth. Remove all sanding dust.
   ASTM E96 A                  4.0 perms
 Weight Solids:                  56 ± 2%                                                 Masonry, Concrete, Cement, Block
 Weight per Gallon:                11.0 lb                                               All new surfaces must be cured accord-
                                                                                         ing to the supplier’s recommenda-
                                                                                         tions—usually about 30 days. Remove
                                                                                         all form release and curing agents.
                                                                                         Rough surfaces can be filled to provide
                                                                                         a smooth surface. If painting cannot wait
                                                                                         30 days, allow the surface to cure 7 days
                                                                                         and prime the surface with Loxon Con-
                                                                                         crete & Masonry Primer.




12/2009                                              www.sherwin-williams.com                                     continued on back
101.26
PROGREEN 200™
LOW VOC
INTERIOR LATEX EG-SHEL
B20-600 SERIES

 SURFACE PREPARATION                                        APPLICATION                                               CAUTIONS
Plaster                                        Apply at temperatures above 50°F.                     For interior use only.
Bare plaster must be cured and hard.           No reduction needed.                                  Protect from freezing.
Textured, soft, porous, or powdery plas-       Brush                                                 Non-photochemically reactive.
ter should be treated with a solution of 1     Use a nylon/polyester brush.
pint household vinegar to 1 gallon of wa-      Roller                                                CAUTIONS
                                                                                                     Use only with adequate ventilation. To avoid overex-
ter. Repeat until the surface is hard, rinse   Use a 3/8" - 3/4" nap synthetic cover.                posure, open windows and doors or use other means
with clear water and allow to dry.             Spray—Airless                                         to ensure fresh air entry during application and drying.
                                               Pressure .............................. 2000 psi      If you experience eye watering, headaches, or dizzi-
Wood                                           Tip ................................... .017"-.021"   ness, increase fresh air, or wear respiratory protection
                                                                                                     (NIOSH approved) or leave the area. Avoid contact
Sand any exposed wood to a fresh sur-                                                                with eyes and skin. Wash hands after using. Keep
face. Patch all holes and imperfections          CLEANUP INFORMATION                                 container closed when not in use. Do not transfer
with a wood filler or putty and sand                                                                 contents to other containers for storage. FIRST AID:
                                                                                                     In case of eye contact, flush thoroughly with large
smooth.                                        Clean spills, spatters, hands and tools               amounts of water. Get medical attention if irritation
                                               immediately after use with soap and warm              persists. If swallowed, call Poison Control Center,
Mildew                                         water. After cleaning, flush spray equip-             hospital emergency room, or physician immediately.
Remove before painting by washing with                                                               WARNING: This product contains chemicals known
                                               ment with mineral spirits to prevent rust-            to the State of California to cause cancer and birth
a solution of 1 part liquid bleach and 3       ing of the equipment. Follow                          defects or other reproductive harm. DO NOT TAKE
parts water. Apply the solution and scrub      manufacturer’s safety recommendations                 INTERNALLY. KEEP OUT OF THE REACH OF
the mildewed area. Allow the solution to                                                             CHILDREN.
                                               when using mineral spirits.                           HOTW 09/22/2008              B20W00651          07 00
remain on the surface for 10 minutes.
Rinse thoroughly with water and allow the
surface to dry before painting. Wear pro-
tective eyewear, waterproof gloves, and
protective clothing. Quickly wash off any
of the mixture that comes in contact with
your skin. Do not add detergents or am-
monia to the bleach/water solution.

Caulking
Gaps between walls, ceilings, crown
moldings, and other interior trim can be
filled with the appropriate caulk after
priming the surface.

                                                                                                     The information and recommendations
                                                                                                     set forth in this Product Data Sheet are
                                                                                                     based upon tests conducted by or on
                                                                                                     behalf of The Sherwin-Williams Com-
                                                                                                     pany. Such information and recommen-
                                                                                                     dations set forth herein are subject to
                                                                                                     change and pertain to the product offered
                                                                                                     at the time of publication. Consult your
                                                                                                     Sherwin-Williams representative to ob-
                                                                                                     tain the most recent Product Data Sheet.
                                                                                                                                 108.04
                                       Formulated for use with the
                              Color-Prime™ System                                                              PREPRITE®
                                                                                                              PROBLOCK®
OTC
      As of 09/22/08, Complies with:
                 Yes LEED® CIv2.0      Yes
                                              INTERIOR/EXTERIOR LATEX PRIMER SEALER
SCAQMD           Yes LEED® NCv2.2      Yes
CARB             Yes LEED® CSv2.0
MPI Spec # 6, 39, 137 LEED® H
                                       Yes
                                        No
                                                                       B51 SERIES
NAHB             Yes


         CHARACTERISTICS                                   CHARACTERISTICS                                  SURFACE PREPARATION
  • Assures uniform appearance of top-              PrepRite ProBlock Interior Latex Primer                WARNING! Removal of old paint by sand-
    coats                                           meets or exceeds the criteria set forth by             ing, scraping or other means may gener-
  • Fast dry                                        the U. S. Green Building Council LEED-                 ate dust or fumes that contain lead. Expo-
  • Assures adhesion of the topcoat to
                                                    NC, Version 2.2 and CI Version 2.0.                    sure to lead dust or fumes may cause brain
    slick, glossy surfaces such as:
    • glossy paints                                 All results have been verified by our ISO              damage or other adverse health effects,
    • varnished or lacquered woodwork               9001 Laboratory.                                       especially in children or pregnant women.
  • Seals out:                                                                                             Controlling exposure to lead or other haz-
    • solvent sensitive stains - tar,                                                                      ardous substances requires the use of
       solvent based markers, etc.                                                                         proper protective equipment, such as a
    • minor dried water stains                                  APPLICATION                                properly fitted respirator (NIOSH approved)
  Use on interior:                                                                                         and proper containment and cleanup. For
  • Drywall              • Cured Plaster            When used outside, must be topcoated                   more information, call the National Lead
  • Ceiling Tiles        • Paneling                 within 14 days with architectural latex or             Information Center at 1-800-424-LEAD (in
  • PVC Piping           • Wall Laminate
                                                    oil finishes.                                          US) or contact your local health authority.
  Use on interior & exterior:
  • Galvanized Metal • Aluminum
  • Wood                 • Hardboard                Apply at temperatures above 50°F.                      Remove all surface contamination by
  • Previously Painted Surfaces                     Do not reduce for stain blocking.                      washing with an appropriate cleaner,
  Color:                              White         No reduction necessary.                                rinse thoroughly and allow to dry. Exist-
  Coverage:                    400 sq ft/gal        Brush - Use a nylon/polyester brush.                   ing peeled or checked paint should be
                 @ 4 mils wet; 1.4 mils dry         Roller - Use a 1/4" - 3/4" nap synthetic               scraped and sanded to a sound surface.
  Drying Time, @ 77°F, 50% RH:                      roller cover.                                          Glossy surfaces should be sanded dull.
  Drying and recoat times are temperature,          Spray—Airless
  humidity and film thickness dependent.            Pressure ................................ 2000 psi     Special recommendations - After prim-
    Touch:                      30 minutes          Tip .................................... .015"-.021"   ing stained areas, allow to dry 4 hours,
    Recoat as a primer                1 hour                                                               test a small area for bleeding by apply-
    Recoat as a stain sealer:       4 hours
                                                      CLEANUP INFORMATION                                  ing the topcoat before painting the entire
  Flash Point:                           N/A
  Finish:                  5-15 units @ 85°                                                                project. If the stain bleeds through, apply
  Tinting with Blend-A-Color:                       Clean spills and spatters immediately with             a second coat of primer and allow to dry
  Base              oz/gal        Strength          soap and warm water. Clean hands and                   overnight and retest before topcoating.
  White              0-4               100%         tools immediately after use with soap and
  Deep Base*        4 - 10             100%         warm water. After cleaning, flush spray                Fire restoration work - Thoroughly clean
  *Must be tinted before using.                     equipment with mineral spirits to prevent              the surface before applying to smoke
  Tinting - For best color development, use         rusting of the equipment. Follow                       stained areas. Apply one or two coats of
  the recommended "P"-shade primer. If              manufacturer's safety recommendations                  PrepRite ProBlock Latex Primer/Sealer
  desired, up to 4 oz per gallon of Blend-A-        when using mineral spirits.                            and test a small area for bleeding before
  Color Toner can be used to approximate                                                                   painting the entire surface.
  the topcoat color. Check color before use.
  Vehicle Type:                Acrylic Latex
                   B51W20
  VOC (less exempt solvents):
                          96 g/L; 0.80 lb/gal
  Volume Solids:                    36 ± 2%
  Weight Solids:                    52 ± 2%
  Weight per Gallon:                  11.1 lb



9/2008                                                     www.sherwin-williams.com                                                 continued on back
108.04
PREPRITE®
PROBLOCK®
INTERIOR/EXTERIOR LATEX PRIMER SEALER
B51 SERIES
 SURFACE PREPARATION                           SURFACE PREPARATION                                            CAUTIONS
General Priming - PrepRite ProBlock In-       Mildew - Remove before painting by            Protect from freezing.
terior/Exterior Latex Primer/Sealer can be    washing with a solution of 1 part liquid
topcoated in 1 hour in non-stain blocking     bleach and 3 parts water. Apply the solu-                          LABEL CAUTIONS
                                                                                            CAUTION contains CRYSTALLINE SILICA. Use only
applications.                                 tion and scrub the mildewed area. Allow       with adequate ventilation. To avoid overexposure,
                                              the solution to remain on the surface for     open windows and doors or use other means to
Spot priming - a nonuniform appearance        10 minutes. Rinse thoroughly with water       ensure fresh air entry during application and drying. If
may result, due to differences in holdout     and allow the surface to dry before paint-    you experience eye watering, headaches, or dizzi-
                                                                                            ness, increase fresh air, or wear respiratory protection
between primed and unprimed areas. To         ing. Wear protective eyewear, waterproof      (NIOSH approved) or leave the area. Adequate ven-
avoid this, prime the entire surface rather   gloves, and protective clothing. Quickly      tilation required when sanding or abrading the dried
than spot priming.                            wash off any of the mixture that comes in     film. If adequate ventilation cannot be provided wear
                                                                                            an approved particulate respirator (NIOSH approved).
                                              contact with your skin. DO NOT ADD DE-        Follow respirator manufacturer’s directions for respi-
Plaster - Must be cured, usually 30 days,     TERGENTS OR AMMONIA TO THE                    rator use. Avoid contact with eyes and skin. Wash
and hard. If painting cannot wait, allow      BLEACH/WATER SOLUTION.                        hands after using. Keep container closed when not in
the surface to dry 7 days and prime with                                                    use. Do not transfer contents to other containers for
                                                                                            storage. FIRST AID: In case of eye contact, flush
PrepRite Masonry Primer. Soft, porous,        Testing - On hard, slick, glossy, or other-   thoroughly with large amounts of water. Get medical
or powdery plaster should be treated with     wise hard to paint surfaces, after prepar-    attention if irritation persists. If swallowed, call Poison
a solution of 1 pint household vinegar to     ing the surface, apply a test area of this    Control Center, hospital emergency room, or physi-
                                                                                            cian immediately. DELAYED EFFECTS FROM LONG
1 gallon of water. Repeat until the sur-      primer, allow to dry properly and test for    TERM OVEREXPOSURE. Abrading or sanding of the
face is hard, rinse with water and allow      adhesion.                                     dry film may release crystalline silica which has been
to dry before painting.                                                                     shown to cause lung damage and cancer under long
                                                                                            term exposure. WARNING: This product contains
                                                                                            chemicals known to the State of California to cause
Wood - Sand any exposed wood to a                                                           cancer and birth defects or other reproductive harm.
fresh surface. Patch all holes and imper-                                                   DO NOT TAKE INTERNALLY. KEEP OUT OF THE
fections with a wood filler or putty and                                                    REACH OF CHILDREN.
                                                                                            HOTW 09/23/2008                B51W00020          20 00
sand smooth.

Tile - Tile, laminate, ceramic and plastic
tiles, and similar glossy surfaces, must
be free of all oil, grease, and soap resi-
due. Do not use this product in areas
subject to excessive water, e.g.: in show-
ers, around sinks, on counter tops.

Caulking - Fill gaps between walls, ceil-
ings, crown moldings, and other trim with                                                   The information and recommendations
the appropriate caulk after priming the                                                     set forth in this Product Data Sheet are
surface.                                                                                    based upon tests conducted by or on
                                                                                            behalf of The Sherwin-Williams Com-
                                                                                            pany. Such information and recommen-
                                                                                            dations set forth herein are subject to
                                                                                            change and pertain to the product offered
                                                                                            at the time of publication. Consult your
                                                                                            Sherwin-Williams representative to obtain
                                                                                            the most recent Product Data Sheet.
                   Uses:                         Features:
                                                                                                                      106.06
                   • Trim Packs/Molding          • Sands easily in 1 hour
                   • Doors/Windows               • Seals wood grain
                   • Paneling                    • High Build
                   • Railing/Furniture
                                                          WOOD CLASSICS®
                                                 • Finish coat in 1½ hours




                                                   FASTDRY SANDING SEALER
                                                                                                                   B26V43
         CHARACTERISTICS                                  SPECIFICATION                          SURFACE PREPARATION
 The Wood Classics System is designed            Suggested system:                              WARNING! Removal of old paint by sand-
 for use on architectural wood in commer-        Smoothness and Speed                           ing, scraping or other means may gener-
 cial, institutional, and residential new con-   1st: Wood Classics Stain (optional)            ate dust or fumes that contain lead. Expo-
 struction and also for refinishing.             2nd: Wood Classics FastDry Sanding             sure to lead dust or fumes may cause brain
 Wood Classics FastDry Sanding Sealer                 Sealer                                    damage or other adverse health effects,
 provides a high build surface and sands         3rd: Wood Classics FastDry Oil Varnish         especially in children or pregnant women.
 fast, easy, and effectively in 1 hour, giving                                                  Controlling exposure to lead or other haz-
 an extremely smooth surface for topcoat-        Shading finishes                               ardous substances requires the use of
 ing. The Sanding Sealer provides an al-         Up to 1 oz. of Wood Classics Stain or 1 oz     proper protective equipment, such as a
 ternative to the first coat of varnish in a 2   of Blend-A-Color Toner (or similar univer-     properly fitted respirator (NIOSH ap-
 coat system.                                    sal colorant) can be added to Wood Clas-       proved) and proper containment and
 Wood Classics FastDry Sanding Sealer            sics to shade the topcoats.                    cleanup. For more information, call the
 can be topcoated in 1½ hours with most                                                         National Lead Information Center at 1-800-
 clear alkyd topcoats.                           White or light colors                          424-LEAD (in US) or contact your local
                                                 When used over a white or very light           health authority.
 Color:                       Clear Amber        stain color, alkyd coatings, such as this
 Coverage:              350 - 500 sq ft/gal      product, will impart a slight yellow cast to   Wood must be dry and cleaned of dirt,
   3.5 - 4.5 mils wet; 1.0 - 1.2 mils dry        the final appearance.                          grease, wax, polish, and marks. Old fin-
 Drying Time, @ 77°F, 50% RH:                                                                   ishes in poor condition should be com-
 temperature and humidity dependent                                                             pletely removed and the surface treated
   To touch:                    20 minutes                                                      as a new surface.
   To sand:                         1 hours
   To topcoat:                 1-1/2 hours                                                      Sand wood to a smooth surface using
 Finish:                45-65 units @ 60°                                                       100-120 grit paper. Remove sanding dust
 Flash Point:                  52°F, PMCC                                                       with a vacuum or tack cloth.
 Shading with Wood Classics Stain:
 Base              oz/gal         Strength                                                      Avoid sanding wood that has only stain
 Clear              0-2                 N/A                                                     on it, sanding will remove some of the
 Tinting with Blend-A-Color Toner:                                                              stain creating an uneven appearance.
 Base              oz/gal         Strength
 Clear              0-1                 N/A                                                     New wood should be stored inside for a
 Vehicle Type:                                                                                  minimum of 24 hours prior to staining.
             Linseed Vinyl Toluene Alkyd                                                        Stain or varnish applied to wood that has
                  B26V43                                                                        not been dried thoroughly can exhibit
 VOC (less exempt solvents):                                                                    blotching, discoloration, or cracking.
                       522 g/L; 4.36 lb/gal
 Volume Solids:                    31 ± 2%
 Weight Solids:                    38 ± 2%
 Weight per Gallon:                   7.0 lb
 OTC Compliant in quarts




1/2005                                                 www.sherwin-williams.com                                         continued on back
106.06

WOOD CLASSICS®
FASTDRY SANDING SEALER
B26V43
              APPLICATION                                                 CAUTIONS
Be sure the temperature is above 50°F                    For interior use only.
and the humidity is below 85%.                           Do not use on floors.
                                                         Do not use under Polyurethane Varnish
Do not shake. Stir thoroughly and occa-                  or lacquers.
sionally during use.
                                                                           LABEL CAUTIONS
No reduction necessary.                                  CAUTION contains ALIPHATIC HYDROCARBONS.
                                                         Contents are FLAMMABLE. Vapors may cause flash
                                                         fires. Keep away from heat, sparks, and open flame.
Brush—Use a natural bristle brush. Brush                 During use and until all vapors are gone: Keep area
out evenly, avoid unnecessary brushing                   ventilated - Do not smoke - Extinguish all flames, pilot
                                                         lights, and heaters - Turn off stoves, electric tools and
into already coated areas. Avoid over-                   appliances, and any other sources of ignition. VAPOR
brushing which causes bubbling.                          HARMFUL. Use only with adequate ventilation. To
                                                         avoid overexposure, open windows and doors or use
Spray—Airless                                            other means to ensure fresh air entry during applica-
                                                         tion and drying. If you experience eye watering, head-
Pressure ................................ 2000 psi       aches, or dizziness, increase fresh air, or wear respi-
Tip .................................. .008" - .013"     ratory protection (NIOSH approved) or leave the area.
                                                         Avoid contact with eyes and skin. Wash hands after
                                                         using. Keep container closed when not in use. Do not
Spray—Conventional                                       transfer contents to other containers for storage. FIRST
Air Pressure .............................. 50 psi       AID: In case of eye contact, flush thoroughly with large
Fluid Pressure ..................... 10-20 psi           amounts of water for 15 minutes and get medical
Cap/Tip ................................... 704/FF       attention. For skin contact, wash thoroughly with soap
                                                         and water. In case of respiratory difficulty, provide
                                                         fresh air and call physician. If swallowed, call Poison
HVLP                                                     Control Center, hospital emergency room, or physi-
                                                         cian immediately. DELAYED EFFECTS FROM LONG
Unit ..................... Graco 3800 or 4900
                                                         TERM OVEREXPOSURE. Contains solvents which
Gun .............................................. 960   can cause permanent brain and nervous system dam-
Tip ................................... 1.4 -1.6 mm      age. Intentional misuse by deliberately concentrating
                                                         and inhaling the contents can be harmful or fatal.
                                                         WARNING: This product contains chemicals known
Allow to dry 1 hour then sand with 180 or                to the State of California to cause cancer and birth
finer grit sandpaper. Although not as ef-                defects or other reproductive harm. DO NOT TAKE
                                                         INTERNALLY. KEEP OUT OF THE REACH OF CHIL-
fective as sandpaper, steel wool and syn-                DREN
thetic abrasive pads may be used for very                HOTW 10/19/2004 B26V00043 04 00
light sanding.

Remove all sanding dust with a tack cloth
or vacuum.
                                                         The information and recommendations
                                                         set forth in this Product Data Sheet are
  CLEANUP INFORMATION                                    based upon tests conducted by or on
                                                         behalf of The Sherwin-Williams Com-
Clean spills, spatters, hands and tools                  pany. Such information and recommen-
immediately after use with mineral spirits.              dations set forth herein are subject to
Follow manufacturer’s safety recommen-                   change and pertain to the product offered
dations when using mineral spirits.                      at the time of publication. Consult your
                                                         Sherwin-Williams representative to obtain
                                                         the most recent Product Data Sheet.
                                                                                                                            107.08

                                                       PORCH & FLOOR ENAMEL
     As of 09/22/08, Complies with:                                                            INTERIOR/EXTERIOR
OTC           Yes LEED® CIv2.0        Yes
SCAQMD
CARB
              Yes LEED® NCv2.2
              Yes LEED® CSv2.0
                                      Yes
                                      Yes                                                        A32-100 SERIES
MPI Spec #     No LEED® H             Yes
NAHB          Yes


              DESCRIPTION                            CHARACTERISTICS                                 SURFACE PREPARATION
  Porch & Floor Enamel is a VOC compli-       Color:                    Most colors                 WARNING! Removal of old paint by sand-
  ant, waterborne coating designed for in-    Coverage:          350 - 400 sq ft/gal                ing, scraping or other means may gener-
  terior and exterior, wood and concrete,               @ 4.0 mils wet; 1.4 mils dry                ate dust or fumes that contain lead. Expo-
  porches and floors                          Drying Time, @ 77°F, 50% RH:                          sure to lead dust or fumes may cause brain
  Porch & Floor Enamel provides chemi-        Drying and recoat times are temperature,              damage or other adverse health effects,
  cal resistance to common household          humidity, and film thickness dependent.               especially in children or pregnant women.
  chemicals.                                    Touch:                            1 hour            Controlling exposure to lead or other haz-
                                                Recoat:                          4 hours            ardous substances requires the use of
  Use for:                                      Light Foot Traffic:             24 hours            proper protective equipment, such as a
  • Interior                                    Tables, Chairs and                                  properly fitted respirator (NIOSH approved)
  • Exterior                                    Heavy Foot Traffic                7 days            and proper containment and cleanup. For
  • Floors                                    Flash Point:                           N/A            more information, call the National Lead
  • Steps                                     Finish:        minimum 65 units at 60°                Information Center at 1-800-424-LEAD (in
                                              Tinting with Blend-A-Color:                           US) or contact your local health authority.
  Use on:                                     Base             oz/gal          Strength
  • Wood and Concrete Floors                  Extra White         0-5              100%             Concrete and Cement Floors
                                              Deep Base          4-12              100%             Concrete must be free of moisture as much
  Outstanding Features:                       Ultradeep          4-12              100%             as possible (moisture seldom drops be-
  • Excellent durability over interior and    Vehicle Type:          Styrenated Acrylic             low 15% in concrete). Test for moisture or
    exterior unprimed wood.                                 A32W00151                               dampness by taping the edges of a 2 foot
  • VOC less than 50 g/L                      VOC (less exempt solvents):                           by 2 foot plastic sheet on the bare surface
  • Excellent water and blister resistance                            45 g/L; 0.37 lb/gal           (an asphalt tile or other moisture impervi-
  • Meets ADA requirements for slip           Volume Solids:                    34 ± 2%             ous material will also do), sealing all of the
    resistance for floors.                    Weight Solids:                    43 ± 2%             edges. After 48 hours, inspect for mois-
                                              Weight per Gallon:                    9.7lb           ture, discoloration, or condensation on the
  • Chemical Resistance                                                                             concrete or the underside of the plastic. If
      household chemicals                                 APPLICATION                               moisture is present, the source must be
      motor oil                                                                                     located and the cause corrected prior to
      anti-freeze                             Stir thoroughly before use.                           painting.
      transmission fluid                      Apply at temperatures above 50°F.
      brake fluid                             No reduction necessary.                               All surfaces must be clean, dry and free
                                              Brush                                                 of grease, oil, paint, sealers, etc. To clean,
  • Excellent for floors and other surfaces   Use a nylon/polyester brush                           use H&C® Degreaser following label di-
  • Uniform gloss appearance                  Roller                                                rections, rinse thoroughly and allow the
  • Easy to apply                             Use a 3/8 to 3/4" 100% Polyester cover                surface to dry.
                                              Spray—Airless
  • Water clean-up                                                                                  Remove by washing with a solution of 1
                                              Pressure ................................ 2000 psi
                                                                                                    part liquid bleach and 3 parts water. Ap-
                                              Tip ................................... .017"-.021"
  Porch & Floor Enamel is not suitable                                                              ply the solution and scrub the mildewed
  for use on garage floors or surfaces                                                              area. Allow the solution to remain on the
  subject to automobile or truck traffic.     Concrete and Wood                                     surface for 10 minutes. Rinse thoroughly
                                              2 cts. Floor Enamel                                   with water and allow the surface to dry
                                              Steel                                                 before painting. Wear protective eyewear,
                                              1 ct. All Surface Enamel Latex Primer                 waterproof gloves, and protective cloth-
                                              2 cts. Floor Enamel                                   ing. Quickly wash off any of the mixture


9/2008                                                www.sherwin-williams.com                                                 continued on back
107.08

PORCH & FLOOR ENAMEL
INTERIOR/EXTERIOR
A32-100 SERIES

 SURFACE PREPARATION                               SURFACE PREPARATION                                              CAUTIONS
that comes in contact with your skin. Do          Wood (Interior and Exterior unprimed)            NOT SUITABLE FOR USE ON FLOORS
not add detergents or ammonia to the              Sand to remove any loose or deteriorated         WHERE THERE WILL BE AUTOMO-
bleach/water solution.                            surface wood and to obtain a proper sur-         BILE OR TRUCK TRAFFIC. NOT SUIT-
                                                  face profile. Patch all holes and imperfec-      ABLE FOR GARAGE FLOORS.
Scrape and sand existing peeled or                tions with a wood filler or putty and sand       Non-photochemically reactive.
checked paint to a sound surface.                 smooth.                                          Protect from freezing.
Sand glossy surfaces dull.
                                                  Steel                                                                   CAUTIONS
                                                                                                   Use only with adequate ventilation. To avoid overex-
Remove all form release agents, curing            Remove rust and mill scale using sand-           posure, open windows and doors or use other means
compounds, salts, efflorescence,                  paper, steel wool, or other abrading             to ensure fresh air entry during application and drying.
laitance, and other foreign matter by             method. Prime bare steel the same day            If you experience eye watering, headaches, or dizzi-
sandblasting, shotblasting, mechanical            as cleaned.                                      ness, increase fresh air, or wear respiratory protection
                                                                                                   (NIOSH approved) or leave the area. Avoid contact
scarification, or suitable chemical means.                                                         with eyes and skin. Wash hands after using. Keep
Refer to ASTM D4260. Rinse thoroughly             Slip Resistance                                  container closed when not in use. Do not transfer
to achieve a final pH between 7.0 and             Some surfaces may require a slip resis-          contents to other containers for storage. FIRST AID: In
                                                                                                   case of eye contact, flush thoroughly with large amounts
10.0. Allow to dry thoroughly prior to coat-      tant additive for safety. Add H&C                of water. Get medical attention if irritation persists. If
ing.                                              SharkGrip® Slip Resistant Additive to the        swallowed, call Poison Control Center, hospital emer-
Surfaces must offer sufficient profile to         final coat applied following label directions.   gency room, or physician immediately. WARNING:
achieve adequate adhesion. If the con-            This product should not be used in place         This product contains chemicals known to the State of
                                                                                                   California to cause cancer and birth defects or other
crete feels like 120-grit sandpaper, the          of a non-skid finish.                            reproductive harm. DO NOT TAKE INTERNALLY.
pores are open enough for this product to                                                          KEEP OUT OF THE REACH OF CHILDREN.
bond properly with the substrate. If the                                                           HOTW 09/22/2008               A32W00151          06 00
                                                    CLEANUP INFORMATION
surface does not have this texture, etch
the surface with H&C® Concrete Etching            Clean spills and spatters immediately with
Solution first, following label directions. For   soap and warm water. Clean hands and
very smooth surfaces (troweled surfaces           tools immediately after use with soap and
with no porosity) use H&C Concrete Etch-          warm water. After cleaning, flush spray
ing Solution at full strength. For smooth-        equipment with mineral spirits to prevent
troweled concrete with some porosity, 1           rusting of the equipment. Follow
part H&C Concrete Etching Solution to two         manufacturer's safety recommendations
parts water should be used. Rough tex-            when using mineral spirits.
tured concrete does not need to be etched.
Do not etch painted surfaces.
Because water will collect in low spots and
deposit etching and cleaning residue, it is                                                        The information and recommendations
recommended that the floor be vacuumed                                                             set forth in this Product Data Sheet are
to remove any remaining water.                                                                     based upon tests conducted by or on
If surface deterioration presents an un-                                                           behalf of The Sherwin-Williams Company.
acceptably rough surface, patch and re-                                                            Such information and recommendations
surface damaged concrete.                                                                          set forth herein are subject to change and
Fill all cracks, voids and bugholes with                                                           pertain to the product offered at the time
ArmorSeal® Crack Filler.                                                                           of publication. Consult your Sherwin-Wil-
                                                                                                   liams representative to obtain the most
                                                                                                   recent Product Data Sheet.
Material Safety Data Sheets
                                             MATERIAL SAFETY DATA SHEET
B66W310                                                                                                  DATE OF PREPARATION
19 00                                                                                                              Jan 10, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B66W310
PRODUCT NAME
  PRO INDUSTRIAL™ PRO-CRYL® Universal Acrylic Primer, Off White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient            Units                                 Vapor Pressure
                 1              112-34-5      2-(2-Butoxyethoxy)-ethanol
                                                     ACGIH TLV               Not Available                0.06 mm
                                                     OSHA PEL                Not Available
                  18              471-34-1    Calcium Carbonate
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          15    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction
                   9           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          10    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                  HMIS Codes
   INHALATION of vapor or spray mist.                                                                               Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                 Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                          Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

          EYES:   Flush eyes with large amounts of water for 15 minutes. Get medical attention.
          SKIN:   Wash affected area thoroughly with soap and water.
                  Remove contaminated clothing and launder before re-use.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.



                                                                                                                     page 1 of 4
B66W310




    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 10.82 lb/gal          1296 g/l
                         SPECIFIC GRAVITY 1.30
                            BOILING POINT 212 - 448 °F        100 - 231 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 60%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 8.7
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.74lb/gal  89g/l Less Water and Federally Exempt Solvents
                         0.32lb/gal  38g/l Emitted VOC




                                                                                                                                        page 2 of 4
B66W310




    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                              Ingredient Name
 112-34-5                             2-(2-Butoxyethoxy)-ethanol
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 5660 mg/kg
 471-34-1                             Calcium Carbonate
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available
 13463-67-7                           Titanium Dioxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
                          Zinc Compound                                                     5                   2.6
                          Glycol Ethers                                                     2
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
B66W310




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




    The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
    additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
    warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                         page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B66W651                                                                                                    DATE OF PREPARATION
08 00                                                                                                                Jan 10, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B66W651
PRODUCT NAME
  PRO INDUSTRIAL™ 0 VOC Acrylic Coating - Semi-Gloss, Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
                13            13463-67-7      Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

         EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
         SKIN:    Wash affected area thoroughly with soap and water.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.

   SECTION 5 — FIRE FIGHTING MEASURES

FLASH POINT                      LEL         UEL                FLAMMABILITY CLASSIFICATION
  Not Applicable                 N.A.        N.A.            Not Applicable
EXTINGUISHING MEDIA
  Carbon Dioxide, Dry Chemical, Alcohol Foam




                                                                                                                       page 1 of 3
B66W651


 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Required for long or repeated contact.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 9.52 lb/gal           1141 g/l
                         SPECIFIC GRAVITY 1.15
                            BOILING POINT 212 - 213 °F        100 - 100 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 63%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.0
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.00lb/gal   0g/l Less Water and Federally Exempt Solvents
                         0.00lb/gal   0g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.




                                                                                                                                        page 2 of 3
B66W651


 HAZARDOUS DECOMPOSITION PRODUCTS
   By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
   Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                              Ingredient Name
 13463-67-7                           Titanium Dioxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
   No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 3 of 3
                                             MATERIAL SAFETY DATA SHEET
B71W211                                                                                                    DATE OF PREPARATION
12 00                                                                                                                Jan 10, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B71W211
PRODUCT NAME
  BOND-PLEX Water Based Coating, Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
                20              471-34-1      Calcium Carbonate
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               15 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                 11            13463-67-7     Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                   1             1314-13-2    Zinc Oxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.




                                                                                                                       page 1 of 4
B71W211




    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.




                                                                                                                                        page 2 of 4
B71W211




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 10.89 lb/gal          1305 g/l
                         SPECIFIC GRAVITY 1.31
                            BOILING POINT 212 - 213 °F        100 - 100 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 58%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.0
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.36lb/gal  43g/l Less Water and Federally Exempt Solvents
                         0.15lb/gal  18g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                              Ingredient Name
 471-34-1                             Calcium Carbonate
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available
 13463-67-7                           Titanium Dioxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available
 1314-13-2                            Zinc Oxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.



                                                                                                                                        page 3 of 4
B71W211




    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
                          Zinc Compound                                                     2                   1.4
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




     The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
     additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
     warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                          page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
A24W100                                                                                                    DATE OF PREPARATION
17 00                                                                                                                Jan 10, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  A24W100
PRODUCT NAME
  LOXON® Masonry Coating Systems Conditioner, Guide Coat White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
               0.9            14464-46-1      Cristobalite
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL           0.05 mg/m3 as Resp. Dust
                   2           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

          EYES:   Flush eyes with large amounts of water for 15 minutes. Get medical attention.
          SKIN:   Wash affected area thoroughly with soap and water.
                  Remove contaminated clothing and launder before re-use.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.

   SECTION 5 — FIRE FIGHTING MEASURES



                                                                                                                       page 1 of 4
A24W100


 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 9.14 lb/gal           1094 g/l
                         SPECIFIC GRAVITY 1.10
                            BOILING POINT 212 - 500 °F        100 - 260 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 81%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.0
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.78lb/gal  93g/l Less Water and Federally Exempt Solvents
                         0.16lb/gal  19g/l Emitted VOC




                                                                                                                                        page 2 of 4
A24W100




    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 14464-46-1                            Cristobalite
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
   No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
A24W100




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




    The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
    additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
    warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                         page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
A5W451                                                                                                     DATE OF PREPARATION
14 00                                                                                                                 Jan 5, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  A5W451
PRODUCT NAME
  ConFlex XL™ High Build Coating, Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
                 8            14808-60-7      Quartz
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL            0.1 mg/m3 as Resp. Dust
                 0.1           14464-46-1     Cristobalite
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL           0.05 mg/m3 as Resp. Dust
                   3           12001-26-2     Mica
                                                     ACGIH TLV               3 mg/m3 as Resp. Dust
                                                     OSHA PEL                3 mg/m3 as Resp. Dust
                 13            13463-67-7     Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                   2             1314-13-2    Zinc Oxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.




                                                                                                                       page 1 of 4
A5W451




    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.




                                                                                                                                        page 2 of 4
A5W451




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 11.40 lb/gal          1366 g/l
                         SPECIFIC GRAVITY 1.37
                            BOILING POINT 212 - 500 °F        100 - 260 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 52%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.0
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.40lb/gal  48g/l Less Water and Federally Exempt Solvents
                         0.20lb/gal  24g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 14808-60-7                            Quartz
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 14464-46-1                            Cristobalite
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 12001-26-2                            Mica
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 1314-13-2                             Zinc Oxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.




                                                                                                                                        page 3 of 4
A5W451




    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
                          Zinc Compound                                                     2                   1.7
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
A6W151                                                                                                     DATE OF PREPARATION
13 00                                                                                                                 Jan 5, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  A6W151
PRODUCT NAME
  A-100® Exterior Flat Latex Paint, Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
               0.1            14464-46-1      Cristobalite
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL           0.05 mg/m3 as Resp. Dust
                 14            13463-67-7     Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                   2             1314-13-2    Zinc Oxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

         EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
         SKIN:    Wash affected area thoroughly with soap and water.
                  Remove contaminated clothing and launder before re-use.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.



                                                                                                                       page 1 of 4
A6W151




    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                               PRODUCT WEIGHT          11.35 lb/gal          1360 g/l
                               SPECIFIC GRAVITY        1.37
                                  BOILING POINT        212 - 213 °F          100 - 100 °C
                                  MELTING POINT        Not Available
                              VOLATILE VOLUME          65%
                             EVAPORATION RATE          Slower than ether
                                 VAPOR DENSITY         Heavier than air
                            SOLUBILITY IN WATER        N.A.
                                             pH        9.0



                                                                                                                                        page 2 of 4
A6W151


      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                          0.40lb/gal   49g/l Less Water and Federally Exempt Solvents
                          0.14lb/gal   17g/l Emitted VOC
      VOLATILE ORGANIC COMPOUNDS (VOC - As Applied)
                        <0.41 lb/gal <50 g/l Less Water and Federally Exempt Solvents

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 14464-46-1                            Cristobalite
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 1314-13-2                             Zinc Oxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.              CHEMICAL/COMPOUND                                                     % by WT                   % Element
                      Zinc Compound                                                         2                         1.7




                                                                                                                                        page 3 of 4
A6W151


 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




     The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
     additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
     warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                          page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
A24W300                                                                                                    DATE OF PREPARATION
24 00                                                                                                                 Jan 5, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  A24W300
PRODUCT NAME
  LOXON® Masonry Coatings System Exterior Acrylic Primer, White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
                 7            14808-60-7      Quartz
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL            0.1 mg/m3 as Resp. Dust
                 0.1           14464-46-1     Cristobalite
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL           0.05 mg/m3 as Resp. Dust
                   3           12001-26-2     Mica
                                                     ACGIH TLV               3 mg/m3 as Resp. Dust
                                                     OSHA PEL                3 mg/m3 as Resp. Dust
                 12            13463-67-7     Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                   1             1314-13-2    Zinc Oxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.




                                                                                                                       page 1 of 4
A24W300




    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.




                                                                                                                                        page 2 of 4
A24W300




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 10.76 lb/gal          1289 g/l
                         SPECIFIC GRAVITY 1.30
                            BOILING POINT 212 - 500 °F        100 - 260 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 59%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.5
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.80lb/gal  96g/l Less Water and Federally Exempt Solvents
                         0.36lb/gal  43g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 14808-60-7                            Quartz
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 14464-46-1                            Cristobalite
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 12001-26-2                            Mica
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 1314-13-2                             Zinc Oxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.




                                                                                                                                        page 3 of 4
A24W300




    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
                          Zinc Compound                                                     1                   1.1
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
A15T5                                                                                                                DATE OF PREPARATION
16 00                                                                                                                          Nov 28, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  A15T5
PRODUCT NAME
  WOODSCAPES® Semi-Transparent Polyurethane Exterior House Stain, Clear Base
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

        % by Weight          CAS Number       Ingredient            Units                                             Vapor Pressure
                  1           25498-49-1      Tripropylene Glycol Methyl Ether
                                                     ACGIH TLV             Not Available                              0.02 mm
                                                     OSHA PEL              Not Available
                   4              107-21-1    Ethylene Glycol
                                                     ACGIH TLV        100 MG/M3 CEILING (aerosol)                     0.12 mm
                                                     OSHA PEL          50 PPM CEILING
                   1            14807-96-6    Talc
                                                     ACGIH TLV           2 mg/m3 as Resp. Dust
                                                     OSHA PEL            2 mg/m3 as Resp. Dust

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                                HMIS Codes
   INHALATION of vapor or spray mist.                                                                                             Health 2
   EYE or SKIN contact with the product, vapor or spray mist.                                                               Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                                        Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
   Prolonged overexposure to solvent ingredients in Section 2 may cause adverse effects to the liver and urinary systems.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

          EYES:   Flush eyes with large amounts of water for 15 minutes. Get medical attention.
          SKIN:   Wash affected area thoroughly with soap and water.
                  Remove contaminated clothing and launder before re-use.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.




                                                                                                                                  page 1 of 4
A15T5




    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                               PRODUCT WEIGHT          8.53 lb/gal           1021 g/l
                               SPECIFIC GRAVITY        1.03
                                  BOILING POINT        212 - 500 °F          100 - 260 °C
                                  MELTING POINT        Not Available
                              VOLATILE VOLUME          91%
                             EVAPORATION RATE          Slower than ether
                                 VAPOR DENSITY         Heavier than air
                            SOLUBILITY IN WATER        N.A.
                                             pH        9.5



                                                                                                                                        page 2 of 4
A15T5


      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         4.14lb/gal 496g/l Less Water and Federally Exempt Solvents
                         0.66lb/gal  79g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   No ingredient in this product is an IARC, NTP or OSHA listed carcinogen.
   Ethylene Glycol is considered an animal teratogen. It has been shown to cause birth defects in rats and mice at high doses when given in
      drinking water or by gavage. There is no evidence to indicate it causes birth defects in humans.
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 25498-49-1                            Tripropylene Glycol Methyl Ether
                                                                LC50 RAT                4HR             Not Available
                                                                LD50 RAT                                3200 mg/kg
 107-21-1                              Ethylene Glycol
                                                                LC50 RAT                4HR             Not Available
                                                                LD50 RAT                                4700 mg/kg
 14807-96-6                            Talc
                                                                LC50 RAT                4HR             Not Available
                                                                LD50 RAT                                Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
 107-21-1                 Ethylene Glycol                                                   4
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
A15T5




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




        The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
        additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
        warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                             page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B42W41                                                                                                               DATE OF PREPARATION
29 00                                                                                                                          Dec 23, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B42W41
PRODUCT NAME
  A-100® Exterior Latex Wood Primer, White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                          Vapor Pressure
                 1              107-21-1      Ethylene Glycol
                                                     ACGIH TLV              100 MG/M3 CEILING (aerosol)               0.12 mm
                                                     OSHA PEL                50 PPM CEILING
                 0.1           14808-60-7     Quartz
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL            0.1 mg/m3 as Resp. Dust
                 0.9           14464-46-1     Cristobalite
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL           0.05 mg/m3 as Resp. Dust
                   5           14807-96-6     Talc
                                                     ACGIH TLV                2 mg/m3 as Resp. Dust
                                                     OSHA PEL                 2 mg/m3 as Resp. Dust
                  15           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV               10 mg/m3 as Dust
                                                     OSHA PEL                10 mg/m3 Total Dust
                                                     OSHA PEL                 5 mg/m3 Respirable Fraction
                   2             1314-13-2    Zinc Oxide
                                                     ACGIH TLV               10 mg/m3 as Dust
                                                     OSHA PEL                10 mg/m3 Total Dust
                                                     OSHA PEL                 5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                                HMIS Codes
   INHALATION of vapor or spray mist.                                                                                             Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                               Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                                        Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
   Prolonged overexposure to solvent ingredients in Section 2 may cause adverse effects to the liver and urinary systems.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.



                                                                                                                                   page 1 of 4
B42W41


 CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.




                                                                                                                                        page 2 of 4
B42W41




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 11.17 lb/gal          1338 g/l
                         SPECIFIC GRAVITY 1.34
                            BOILING POINT 212 - 500 °F        100 - 260 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 64%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 8.8
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.72lb/gal  87g/l Less Water and Federally Exempt Solvents
                         0.28lb/gal  33g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
   Ethylene Glycol is considered an animal teratogen. It has been shown to cause birth defects in rats and mice at high doses when given in
      drinking water or by gavage. There is no evidence to indicate it causes birth defects in humans.
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 107-21-1                              Ethylene Glycol
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               4700 mg/kg
 14808-60-7                            Quartz
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 14464-46-1                            Cristobalite
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 14807-96-6                            Talc
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 1314-13-2                             Zinc Oxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.




                                                                                                                                        page 3 of 4
B42W41




    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
 107-21-1                 Ethylene Glycol                                                   1
                          Zinc Compound                                                     2                   1.7
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
TM2160                                                                                                               DATE OF PREPARATION
23 00                                                                                                                          Nov 30, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  TM2160
PRODUCT NAME
  SETFAST® Acrylic Latex Traffic Marking Paint, White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                          Vapor Pressure
                 2               67-56-1      Methanol
                                                     ACGIH TLV              200   PPM (Skin)                          92 mm
                                                     ACGIH TLV              250   PPM (Skin) STEL
                                                     OSHA PEL               200   PPM (Skin)
                                                     OSHA PEL               250   PPM (Skin) STEL
                  53              471-34-1    Calcium Carbonate
                                                     ACGIH TLV               10 mg/m3 as Dust
                                                     OSHA PEL                15 mg/m3 Total Dust
                                                     OSHA PEL                 5 mg/m3 Respirable Fraction
                   5           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV               10 mg/m3 as Dust
                                                     OSHA PEL                10 mg/m3 Total Dust
                                                     OSHA PEL                 5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                                HMIS Codes
   INHALATION of vapor or spray mist.                                                                                             Health 3*
   EYE or SKIN contact with the product, vapor or spray mist.                                                               Flammability 2
EFFECTS OF OVEREXPOSURE                                                                                                        Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   May cause nervous system depression. Extreme overexposure may result in unconsciousness and possibly death.
   Prolonged overexposure to solvent ingredients in Section 2 may cause adverse effects to the liver and urinary systems.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Headache, dizziness, nausea, and loss of coordination are indications of excessive exposure to vapors or spray mists.
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.




                                                                                                                                   page 1 of 4
TM2160




    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL            UEL           FLAMMABILITY CLASSIFICATION
   150 °F PMCC                       6.0            36.5       Combustible, Flash above 99 and below 200 °F
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   Application to hot surfaces requires special precautions.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   DOL Storage Class IIIA
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Contents are COMBUSTIBLE. Keep away from heat and open flame.
   Consult NFPA Code. Use approved Bonding and Grounding procedures.
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
     Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.
 OTHER PRECAUTIONS
   Intentional misuse by deliberately concentrating and inhaling the contents can be harmful or fatal.




                                                                                                                                        page 2 of 4
TM2160




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 13.32 lb/gal          1595 g/l
                         SPECIFIC GRAVITY 1.60
                            BOILING POINT 148 - 500 °F        64 - 260 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 45%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.2
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.75lb/gal  90g/l Less Water and Federally Exempt Solvents
                         0.46lb/gal  55g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
    Reports have associated repeated and prolonged overexposure to solvents with permanent brain and nervous system damage.
    IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
       inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
       significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
       paint."
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 67-56-1                               Methanol
                                                                   LC50 RAT               4HR               64000 ppm
                                                                   LD50 RAT                                 5630 mg/kg
 471-34-1                              Calcium Carbonate
                                                                   LC50 RAT               4HR               Not Available
                                                                   LD50 RAT                                 Not Available
 13463-67-7                            Titanium Dioxide
                                                                   LC50 RAT               4HR               Not Available
                                                                   LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
   Not Regulated for Transportation.
 Canada (TDG)
   Not Regulated for Transportation.




                                                                                                                                         page 3 of 4
TM2160


 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
 67-56-1                  Methanol                                                          2
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B51W50                                                                                                     DATE OF PREPARATION
11 00                                                                                                                Nov 30, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B51W50
PRODUCT NAME
  PrepRite® Interior/Exterior Bonding Primer, White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
                 9            14808-60-7      Quartz
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL            0.1 mg/m3 as Resp. Dust
                   4           12001-26-2     Mica
                                                     ACGIH TLV               3 mg/m3 as Resp. Dust
                                                     OSHA PEL                3 mg/m3 as Resp. Dust
                 12               471-34-1    Calcium Carbonate
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               15 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                   9           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.




                                                                                                                       page 1 of 4
B51W50




    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.




                                                                                                                                        page 2 of 4
B51W50




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 11.07 lb/gal          1325 g/l
                         SPECIFIC GRAVITY 1.33
                            BOILING POINT 212 - 213 °F        100 - 100 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 57%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.0
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.37lb/gal  44g/l Less Water and Federally Exempt Solvents
                         0.16lb/gal  19g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 14808-60-7                            Quartz
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 12001-26-2                            Mica
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 471-34-1                              Calcium Carbonate
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.




                                                                                                                                        page 3 of 4
B51W50




    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
   No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B66W211                                                                                                  DATE OF PREPARATION
21 00                                                                                                              Jan 10, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B66W211
PRODUCT NAME
  DTM ACRYLIC Semi-Gloss Acrylic Coating, Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient            Units                                 Vapor Pressure
                 4              111-77-3      2-(2-Methoxyethoxy)-ethanol
                                                     ACGIH TLV               Not Available                1 mm
                                                     OSHA PEL                Not Available
                  0.1           14464-46-1    Cristobalite
                                                     ACGIH TLV      0.025    mg/m3 as Resp. Dust
                                                     OSHA PEL        0.05    mg/m3 as Resp. Dust
                  16            13463-67-7    Titanium Dioxide
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          10    mg/m3 Total Dust
                                                     OSHA PEL           5    mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                  HMIS Codes
   INHALATION of vapor or spray mist.                                                                               Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                 Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                          Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

          EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
          SKIN:    Wash affected area thoroughly with soap and water.
                   Remove contaminated clothing and launder before re-use.
  INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:     Do not induce vomiting. Get medical attention immediately.




                                                                                                                     page 1 of 4
B66W211




    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 10.03 lb/gal           1201 g/l
                         SPECIFIC GRAVITY 1.21
                            BOILING POINT 212 - 500 °F         100 - 260 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 62%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                        pH 9.5
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         1.44lb/gal  172g/l Less Water and Federally Exempt Solvents
                         0.66lb/gal   79g/l Emitted VOC




                                                                                                                                        page 2 of 4
B66W211




    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 111-77-3                              2-(2-Methoxyethoxy)-ethanol
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               5500 mg/kg
 14464-46-1                            Cristobalite
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
                          Glycol Ethers                                                     4
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
B66W211




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




    The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
    additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
    warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                         page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B21W251                                                                                                              DATE OF PREPARATION
13 00                                                                                                                          Nov 30, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B21W251
PRODUCT NAME
  PROMAR® 200 Interior Latex Gloss Enamel, Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient            Units                                             Vapor Pressure
                 1            64742-54-7      Heavy Pariffinic Oil
                                                     ACGIH TLV           5   mg/m3 as Mist                            0.0004 mm
                                                     OSHA PEL            5   mg/m3 as Mist
                   3              112-34-5    2-(2-Butoxyethoxy)-ethanol
                                                     ACGIH TLV               Not Available                            0.06 mm
                                                     OSHA PEL                Not Available
                   3              107-21-1    Ethylene Glycol
                                                     ACGIH TLV        100    MG/M3 CEILING (aerosol)                  0.12 mm
                                                     OSHA PEL          50    PPM CEILING
                 0.1           14464-46-1     Cristobalite
                                                     ACGIH TLV      0.025    mg/m3 as Resp. Dust
                                                     OSHA PEL        0.05    mg/m3 as Resp. Dust
                  14           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          10    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                                HMIS Codes
   INHALATION of vapor or spray mist.                                                                                             Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                               Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                                        Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
   Prolonged overexposure to solvent ingredients in Section 2 may cause adverse effects to the liver and urinary systems.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.




                                                                                                                                   page 1 of 4
B21W251




    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.




                                                                                                                                        page 2 of 4
B21W251




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 9.77 lb/gal            1170 g/l
                         SPECIFIC GRAVITY 1.18
                            BOILING POINT 212 - 448 °F         100 - 231 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 62%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                        pH 9.5
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         1.23lb/gal  148g/l Less Water and Federally Exempt Solvents
                         0.54lb/gal   64g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
   Ethylene Glycol is considered an animal teratogen. It has been shown to cause birth defects in rats and mice at high doses when given in
      drinking water or by gavage. There is no evidence to indicate it causes birth defects in humans.
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 64742-54-7                            Heavy Pariffinic Oil
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 112-34-5                              2-(2-Butoxyethoxy)-ethanol
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               5660 mg/kg
 107-21-1                              Ethylene Glycol
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               4700 mg/kg
 14464-46-1                            Cristobalite
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.




                                                                                                                                        page 3 of 4
B21W251


    Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
        regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
 107-21-1                 Ethylene Glycol                                                   3
                          Glycol Ethers                                                     3
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B31W651                                                                                                  DATE OF PREPARATION
04 00                                                                                                              Nov 30, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B31W651
PRODUCT NAME
  ProGreen™ 200 Low VOC Interior Latex Semi-Gloss Paint, Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient            Units                                 Vapor Pressure
                 2              112-34-5      2-(2-Butoxyethoxy)-ethanol
                                                     ACGIH TLV               Not Available                0.06 mm
                                                     OSHA PEL                Not Available
                   4              471-34-1    Calcium Carbonate
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          15    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction
                  13           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          10    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                  HMIS Codes
   INHALATION of vapor or spray mist.                                                                               Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                 Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                          Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

          EYES:   Flush eyes with large amounts of water for 15 minutes. Get medical attention.
          SKIN:   Wash affected area thoroughly with soap and water.
                  Remove contaminated clothing and launder before re-use.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.



                                                                                                                     page 1 of 4
B31W651




    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                               PRODUCT WEIGHT          10.34 lb/gal          1238 g/l
                               SPECIFIC GRAVITY        1.24
                                  BOILING POINT        212 - 448 °F          100 - 231 °C
                                  MELTING POINT        Not Available
                              VOLATILE VOLUME          57%
                             EVAPORATION RATE          Slower than ether
                                 VAPOR DENSITY         Heavier than air
                            SOLUBILITY IN WATER        N.A.
                                             pH        9.3



                                                                                                                                        page 2 of 4
B31W651


      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.39lb/gal 46g/l Less Water and Federally Exempt Solvents
                         0.17lb/gal 20g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                              Ingredient Name
 112-34-5                             2-(2-Butoxyethoxy)-ethanol
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 5660 mg/kg
 471-34-1                             Calcium Carbonate
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available
 13463-67-7                           Titanium Dioxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
                          Glycol Ethers                                                     2
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
B31W651




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




    The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
    additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
    warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                         page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B42W2                                                                                                      DATE OF PREPARATION
16 00                                                                                                                Jan 10, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B42W2
PRODUCT NAME
  Waterborne Acrylic Dry Fall, Eg-Shel Brilliant White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
                11              471-34-1      Calcium Carbonate
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               15 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                 14            13463-67-7     Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

         EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
         SKIN:    Wash affected area thoroughly with soap and water.
                  Remove contaminated clothing and launder before re-use.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.

   SECTION 5 — FIRE FIGHTING MEASURES


                                                                                                                       page 1 of 4
B42W2


                                                                  FLAMMABILITY CLASSIFICATION
 FLASH POINT                         LEL           UEL         Not Applicable
   Not Applicable                    N.A.          N.A.           EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 10.54 lb/gal          1263 g/l
                         SPECIFIC GRAVITY 1.27
                            BOILING POINT 212 - 213 °F        100 - 100 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 59%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.5
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.58lb/gal  70g/l Less Water and Federally Exempt Solvents
                         0.26lb/gal  31g/l Emitted VOC




                                                                                                                                        page 2 of 4
B42W2




    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                              Ingredient Name
 471-34-1                             Calcium Carbonate
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available
 13463-67-7                           Titanium Dioxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
   No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
B42W2




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




    The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
    additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
    warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                         page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B25W25                                                                                                     DATE OF PREPARATION
32 00                                                                                                                Jan 10, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B25W25
PRODUCT NAME
  PrepRite® Interior/Exterior Latex Block Filler, White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
               0.2            14808-60-7      Quartz
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL            0.1 mg/m3 as Resp. Dust
                   4             1332-58-7    Kaolin
                                                     ACGIH TLV               2 mg/m3 as Resp. Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                 53               471-34-1    Calcium Carbonate
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               15 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction
                   1           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.




                                                                                                                       page 1 of 4
B25W25




    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.




                                                                                                                                        page 2 of 4
B25W25




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 13.49 lb/gal          1616 g/l
                         SPECIFIC GRAVITY 1.62
                            BOILING POINT 212 - 213 °F        100 - 100 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 52%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 8.7
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.37lb/gal  44g/l Less Water and Federally Exempt Solvents
                         0.18lb/gal  22g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 14808-60-7                            Quartz
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 1332-58-7                             Kaolin
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 471-34-1                              Calcium Carbonate
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.




                                                                                                                                        page 3 of 4
B25W25




    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
   No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B28W600                                                                                                  DATE OF PREPARATION
08 00                                                                                                              Jan 10, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B28W600
PRODUCT NAME
  ProGreen™ 200 Low Odor/Low VOC Interior Latex Primer, White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient            Units                                 Vapor Pressure
                 1              112-34-5      2-(2-Butoxyethoxy)-ethanol
                                                     ACGIH TLV               Not Available                0.06 mm
                                                     OSHA PEL                Not Available
                  28              471-34-1    Calcium Carbonate
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          15    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction
                  12           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          10    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                  HMIS Codes
   INHALATION of vapor or spray mist.                                                                               Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                 Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                          Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

          EYES:   Flush eyes with large amounts of water for 15 minutes. Get medical attention.
          SKIN:   Wash affected area thoroughly with soap and water.
                  Remove contaminated clothing and launder before re-use.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.



                                                                                                                     page 1 of 4
B28W600




    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                               PRODUCT WEIGHT          12.44 lb/gal          1490 g/l
                               SPECIFIC GRAVITY        1.50
                                  BOILING POINT        212 - 448 °F          100 - 231 °C
                                  MELTING POINT        Not Available
                              VOLATILE VOLUME          61%
                             EVAPORATION RATE          Slower than ether
                                 VAPOR DENSITY         Heavier than air
                            SOLUBILITY IN WATER        N.A.
                                             pH        8.8



                                                                                                                                        page 2 of 4
B28W600


      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.36lb/gal 43g/l Less Water and Federally Exempt Solvents
                         0.14lb/gal 17g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                              Ingredient Name
 112-34-5                             2-(2-Butoxyethoxy)-ethanol
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 5660 mg/kg
 471-34-1                             Calcium Carbonate
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available
 13463-67-7                           Titanium Dioxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
                          Glycol Ethers                                                     1
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
B28W600




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




    The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
    additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
    warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                         page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B20W651                                                                                                  DATE OF PREPARATION
08 00                                                                                                              Nov 30, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B20W651
PRODUCT NAME
  ProGreen™ 200 Low VOC Interior Latex Eg-Shel Paint, Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient            Units                                 Vapor Pressure
                 1              112-34-5      2-(2-Butoxyethoxy)-ethanol
                                                     ACGIH TLV               Not Available                0.06 mm
                                                     OSHA PEL                Not Available
                  14              471-34-1    Calcium Carbonate
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          15    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction
                  16           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV         10    mg/m3 as Dust
                                                     OSHA PEL          10    mg/m3 Total Dust
                                                     OSHA PEL            5   mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                  HMIS Codes
   INHALATION of vapor or spray mist.                                                                               Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                 Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                          Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

          EYES:   Flush eyes with large amounts of water for 15 minutes. Get medical attention.
          SKIN:   Wash affected area thoroughly with soap and water.
                  Remove contaminated clothing and launder before re-use.
  INHALATION:     If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:    Do not induce vomiting. Get medical attention immediately.



                                                                                                                     page 1 of 4
B20W651




    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                               PRODUCT WEIGHT          11.01 lb/gal          1319 g/l
                               SPECIFIC GRAVITY        1.32
                                  BOILING POINT        212 - 448 °F          100 - 231 °C
                                  MELTING POINT        Not Available
                              VOLATILE VOLUME          57%
                             EVAPORATION RATE          Slower than ether
                                 VAPOR DENSITY         Heavier than air
                            SOLUBILITY IN WATER        N.A.
                                             pH        9.3



                                                                                                                                        page 2 of 4
B20W651


      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.34lb/gal 40g/l Less Water and Federally Exempt Solvents
                         0.15lb/gal 18g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                              Ingredient Name
 112-34-5                             2-(2-Butoxyethoxy)-ethanol
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 5660 mg/kg
 471-34-1                             Calcium Carbonate
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available
 13463-67-7                           Titanium Dioxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
                          Glycol Ethers                                                     1
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
B20W651




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




    The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
    additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
    warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                         page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B51W20                                                                                                               DATE OF PREPARATION
22 00                                                                                                                           Jan 5, 2010

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B51W20
PRODUCT NAME
  PrepRite® ProBlock® Interior/Exterior Latex Primer/Sealer, White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                          Vapor Pressure
                 1              107-21-1      Ethylene Glycol
                                                     ACGIH TLV              100 MG/M3 CEILING (aerosol)               0.12 mm
                                                     OSHA PEL                50 PPM CEILING
                 0.4           14464-46-1     Cristobalite
                                                     ACGIH TLV         0.025 mg/m3 as Resp. Dust
                                                     OSHA PEL           0.05 mg/m3 as Resp. Dust
                   3           14807-96-6     Talc
                                                     ACGIH TLV                2 mg/m3 as Resp. Dust
                                                     OSHA PEL                 2 mg/m3 as Resp. Dust
                  17           13463-67-7     Titanium Dioxide
                                                     ACGIH TLV               10 mg/m3 as Dust
                                                     OSHA PEL                10 mg/m3 Total Dust
                                                     OSHA PEL                 5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                                HMIS Codes
   INHALATION of vapor or spray mist.                                                                                             Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                               Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                                        Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
   Prolonged overexposure to solvent ingredients in Section 2 may cause adverse effects to the liver and urinary systems.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.




                                                                                                                                   page 1 of 4
B51W20




    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL           UEL            FLAMMABILITY CLASSIFICATION
   Not Applicable                    N.A.          N.A.        Not Applicable
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.




                                                                                                                                        page 2 of 4
B51W20




    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 11.13 lb/gal          1333 g/l
                         SPECIFIC GRAVITY 1.34
                            BOILING POINT 212 - 500 °F        100 - 260 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 64%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.0
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.80lb/gal  96g/l Less Water and Federally Exempt Solvents
                         0.31lb/gal  38g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Crystalline Silica (Quartz, Cristobalite) is listed by IARC and NTP. Long term exposure to high levels of silica dust, which can occur only when
      sanding or abrading the dry film, may cause lung damage (silicosis) and possibly cancer.
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
   Ethylene Glycol is considered an animal teratogen. It has been shown to cause birth defects in rats and mice at high doses when given in
      drinking water or by gavage. There is no evidence to indicate it causes birth defects in humans.
 TOXICOLOGY DATA
 CAS No.                               Ingredient Name
 107-21-1                              Ethylene Glycol
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               4700 mg/kg
 14464-46-1                            Cristobalite
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 14807-96-6                            Talc
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available
 13463-67-7                            Titanium Dioxide
                                                                    LC50 RAT             4HR               Not Available
                                                                    LD50 RAT                               Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.




                                                                                                                                        page 3 of 4
B51W20




    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
 107-21-1                 Ethylene Glycol                                                   1
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
B26V43                                                                                                               DATE OF PREPARATION
08 00                                                                                                                          Nov 28, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  B26V43
PRODUCT NAME
  WOOD CLASSICS® FastDry Sanding Sealer, Clear
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

           % by Weight                CAS Number       Ingredient                  Units                         Vapor Pressure
                    18                 64742-89-8      Lt. Aliphatic Hydrocarbon Solvent
                                                                   ACGIH TLV         100    PPM                  53 mm
                                                                   OSHA PEL          100    PPM
                      18                64742-89-8     V. M. & P. Naphtha
                                                                   ACGIH TLV         300    PPM                  12 mm
                                                                   OSHA PEL          300    PPM
                                                                   OSHA PEL          400    PPM STEL
                      26                64742-88-7     Mineral Spirits
                                                                   ACGIH TLV         100    PPM                  2 mm
                                                                   OSHA PEL          100    PPM
                     0.8                   100-41-4    Ethylbenzene
                                                                   ACGIH TLV         100    PPM                  7.1 mm
                                                                   ACGIH TLV         125    PPM STEL
                                                                   OSHA PEL          100    PPM
                                                                   OSHA PEL          125    PPM STEL
                       2                  1330-20-7    Xylene
                                                                   ACGIH TLV         100    PPM                  5.9 mm
                                                                   ACGIH TLV         150    PPM STEL
                                                                   OSHA PEL          100    PPM
                                                                   OSHA PEL          150    PPM STEL

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                               HMIS Codes
   INHALATION of vapor or spray mist.                                                                                            Health 2*
   EYE or SKIN contact with the product, vapor or spray mist.                                                              Flammability 3
EFFECTS OF OVEREXPOSURE                                                                                                       Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   May cause nervous system depression. Extreme overexposure may result in unconsciousness and possibly death.
   Prolonged overexposure to solvent ingredients in Section 2 may cause adverse effects to the liver, urinary and reproductive systems.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Headache, dizziness, nausea, and loss of coordination are indications of excessive exposure to vapors or spray mists.
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.




                                                                                                                                    page 1 of 4
B26V43


 MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
 CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

    SECTION 4 — FIRST AID MEASURES

           EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
           SKIN:    Wash affected area thoroughly with soap and water.
                    Remove contaminated clothing and launder before re-use.
   INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
     INGESTION:     Do not induce vomiting. Get medical attention immediately.

    SECTION 5 — FIRE FIGHTING MEASURES

 FLASH POINT                         LEL            UEL           FLAMMABILITY CLASSIFICATION
   50 °F PMCC                        0.9            7.1        RED LABEL -- Flammable, Flash below 100 °F (38 °C)
 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode when exposed to extreme heat.
   Application to hot surfaces requires special precautions.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   DOL Storage Class IB
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Contents are FLAMMABLE. Keep away from heat, sparks, and open flame.
   During use and until all vapors are gone: Keep area ventilated - Do not smoke - Extinguish all flames, pilot lights, and heaters - Turn off
      stoves, electric tools and appliances, and any other sources of ignition.
   Consult NFPA Code. Use approved Bonding and Grounding procedures.
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.




                                                                                                                                        page 2 of 4
B26V43


   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.
 OTHER PRECAUTIONS
   Intentional misuse by deliberately concentrating and inhaling the contents can be harmful or fatal.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                        PRODUCT WEIGHT 6.95 lb/gal            833 g/l
                        SPECIFIC GRAVITY 0.84
                           BOILING POINT 200 - 395 °F         93 - 201 °C
                           MELTING POINT Not Available
                       VOLATILE VOLUME 71%
                      EVAPORATION RATE Slower than ether
                          VAPOR DENSITY Heavier than air
                     SOLUBILITY IN WATER N.A.
     VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                        4.52lb/gal  542g/l Less Water and Federally Exempt Solvents
                        4.52lb/gal  542g/l Emitted VOC

    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   Reports have associated repeated and prolonged overexposure to solvents with permanent brain and nervous system damage.
   Ethylbenzene is classified by IARC as possibly carcinogenic to humans (2B) based on inadequate evidence in humans and sufficient
      evidence in laboratory animals. Lifetime inhalation exposure of rats and mice to high ethylbenzene concentrations resulted in increases in
      certain types of cancer, including kidney tumors in rats and lung and liver tumors in mice. These effects were not observed in animals
      exposed to lower concentrations. There is no evidence that ethylbenzene causes cancer in humans.
 TOXICOLOGY DATA
 CAS No.                             Ingredient Name
 64742-89-8                          Lt. Aliphatic Hydrocarbon Solvent
                                                                 LC50 RAT               4HR             Not Available
                                                                 LD50 RAT                               Not Available
 64742-89-8                          V. M. & P. Naphtha
                                                                 LC50 RAT               4HR             Not Available
                                                                 LD50 RAT                               Not Available
 64742-88-7                          Mineral Spirits
                                                                 LC50 RAT               4HR             Not Available
                                                                 LD50 RAT                               Not Available
 100-41-4                            Ethylbenzene
                                                                 LC50 RAT               4HR             Not Available
                                                                 LD50 RAT                               3500 mg/kg
 1330-20-7                           Xylene
                                                                 LC50 RAT               4HR             5000 ppm
                                                                 LD50 RAT                               4300 mg/kg

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.




                                                                                                                                      page 3 of 4
B26V43




    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product may be hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Waste must be tested for ignitability to determine the applicable EPA hazardous waste numbers.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    1 Gallon and Less may be Classed as CONSUMER COMMODITY, ORM-D
    Larger Containers are Regulated as:
    UN1263, PAINT, 3, PG II, (ERG#128)
 DOT (Dept of Transportation) Hazardous Substances & Reportable Quantities
    Xylenes (isomers and mixture) 100 lb RQ
 Bulk Containers may be Shipped as (check reportable quantities):
    UN1263, PAINT, 3, PG II, (ERG#128)
 Canada (TDG)
    UN1263, PAINT, CLASS 3, PG II, (ERG#128)
 IMO
    UN1263, PAINT, CLASS 3, PG II, (10 C c.c.), EmS F-E, S-E

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                    CHEMICAL/COMPOUND                                                 % by WT            % Element
 100-41-4                   Ethylbenzene                                                      0.7
 1330-20-7                  Xylene                                                            2
                            Zinc Compound                                                     4                  0.5
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.

    SECTION 16 — OTHER INFORMATION

    This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
       MSDS contains all of the information required by the CPR.




      The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
      additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
      warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                           page 4 of 4
                                             MATERIAL SAFETY DATA SHEET
A32W151                                                                                                    DATE OF PREPARATION
08 00                                                                                                                Nov 28, 2009

   SECTION 1 — PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NUMBER
  A32W151
PRODUCT NAME
  Porch & Floor Enamel (Interior/Exterior Waterborne Formula), Extra White
MANUFACTURER'S NAME
  THE SHERWIN-WILLIAMS COMPANY
  101 Prospect Avenue N.W.
  Cleveland, OH 44115
Telephone Numbers and Websites
             Product Information     www.sherwin-williams.com
          Regulatory Information     (216) 566-2902
                                     www.paintdocs.com
                Medical Emergency (216) 566-2917
        Transportation Emergency* (800) 424-9300
  *for Chemical Emergency ONLY (spill, leak, fire, exposure, or accident)


   SECTION 2 — COMPOSITION/INFORMATION ON INGREDIENTS

       % by Weight           CAS Number       Ingredient               Units                                Vapor Pressure
                15            13463-67-7      Titanium Dioxide
                                                     ACGIH TLV              10 mg/m3 as Dust
                                                     OSHA PEL               10 mg/m3 Total Dust
                                                     OSHA PEL                5 mg/m3 Respirable Fraction

   SECTION 3 — HAZARDS IDENTIFICATION

ROUTES OF EXPOSURE                                                                                                    HMIS Codes
   INHALATION of vapor or spray mist.                                                                                 Health 1*
   EYE or SKIN contact with the product, vapor or spray mist.                                                   Flammability 0
EFFECTS OF OVEREXPOSURE                                                                                            Reactivity 0
        EYES: Irritation.
         SKIN: Prolonged or repeated exposure may cause irritation.
  INHALATION: Irritation of the upper respiratory system.

   In a confined area vapors in high concentration may cause headache, nausea or dizziness.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
   Redness and itching or burning sensation may indicate eye or excessive skin exposure.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
   None generally recognized.
CANCER INFORMATION
   For complete discussion of toxicology data refer to Section 11.

   SECTION 4 — FIRST AID MEASURES

          EYES:    Flush eyes with large amounts of water for 15 minutes. Get medical attention.
          SKIN:    Wash affected area thoroughly with soap and water.
                   Remove contaminated clothing and launder before re-use.
  INHALATION:      If affected, remove from exposure. Restore breathing. Keep warm and quiet.
    INGESTION:     Do not induce vomiting. Get medical attention immediately.

   SECTION 5 — FIRE FIGHTING MEASURES

FLASH POINT                         LEL           UEL           FLAMMABILITY CLASSIFICATION
  Not Applicable                    N.A.          N.A.       Not Applicable




                                                                                                                       page 1 of 4
A32W151


 EXTINGUISHING MEDIA
   Carbon Dioxide, Dry Chemical, Alcohol Foam
 UNUSUAL FIRE AND EXPLOSION HAZARDS
   Closed containers may explode (due to the build-up of pressure) when exposed to extreme heat.
   During emergency conditions overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately
      apparent. Obtain medical attention.
 SPECIAL FIRE FIGHTING PROCEDURES
   Full protective equipment including self-contained breathing apparatus should be used.
   Water spray may be ineffective. If water is used, fog nozzles are preferable. Water may be used to cool closed containers to prevent pressure
      build-up and possible autoignition or explosion when exposed to extreme heat.

    SECTION 6 — ACCIDENTAL RELEASE MEASURES

 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
     Remove all sources of ignition. Ventilate the area.
     Remove with inert absorbent.

    SECTION 7 — HANDLING AND STORAGE

 STORAGE CATEGORY
   Not Applicable
 PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
   Keep container closed when not in use. Transfer only to approved containers with complete and appropriate labeling. Do not take internally.
      Keep out of the reach of children.

    SECTION 8 — EXPOSURE CONTROLS/PERSONAL PROTECTION

 PRECAUTIONS TO BE TAKEN IN USE
   Use only with adequate ventilation.
   Avoid contact with skin and eyes. Avoid breathing vapor and spray mist.
   Wash hands after using.
   This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be present at hazardous levels
       only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2, the applicable limits for nuisance dusts are
       ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
   Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may
       cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other
       hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper
       containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local
       health authority.
 VENTILATION
   Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 is maintained below applicable exposure limits.
       Refer to OSHA Standards 1910.94, 1910.107, 1910.108.
 RESPIRATORY PROTECTION
   If personal exposure cannot be controlled below applicable limits by ventilation, wear a properly fitted organic vapor/particulate respirator
       approved by NIOSH/MSHA for protection against materials in Section 2.
   When sanding or abrading the dried film, wear a dust/mist respirator approved by NIOSH/MSHA for dust which may be generated from this
       product, underlying paint, or the abrasive.
 PROTECTIVE GLOVES
   Wear gloves which are recommended by glove supplier for protection against materials in Section 2.
 EYE PROTECTION
   Wear safety spectacles with unperforated sideshields.

    SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES

                         PRODUCT WEIGHT 9.64 lb/gal           1155 g/l
                         SPECIFIC GRAVITY 1.16
                            BOILING POINT 212 - 213 °F        100 - 100 °C
                            MELTING POINT Not Available
                        VOLATILE VOLUME 65%
                       EVAPORATION RATE Slower than ether
                           VAPOR DENSITY Heavier than air
                      SOLUBILITY IN WATER N.A.
                                       pH 9.0
      VOLATILE ORGANIC COMPOUNDS (VOC Theoretical - As Packaged)
                         0.37lb/gal  45g/l Less Water and Federally Exempt Solvents
                         0.13lb/gal  16g/l Emitted VOC




                                                                                                                                        page 2 of 4
A32W151




    SECTION 10 — STABILITY AND REACTIVITY

 STABILITY — Stable
 CONDITIONS TO AVOID
    None known.
 INCOMPATIBILITY
    None known.
 HAZARDOUS DECOMPOSITION PRODUCTS
    By fire: Carbon Dioxide, Carbon Monoxide
 HAZARDOUS POLYMERIZATION
    Will not occur

    SECTION 11 — TOXICOLOGICAL INFORMATION

 CHRONIC HEALTH HAZARDS
   IARC's Monograph No. 93 reports there is sufficient evidence of carcinogenicity in experimental rats exposed to titanium dioxide but
      inadequate evidence for carcinogenicity in humans and has assigned a Group 2B rating. In addition, the IARC summary concludes, "No
      significant exposure to titanium dioxide is thought to occur during the use of products in which titanium is bound to other materials, such as
      paint."
 TOXICOLOGY DATA
 CAS No.                              Ingredient Name
 13463-67-7                           Titanium Dioxide
                                                                  LC50 RAT               4HR               Not Available
                                                                  LD50 RAT                                 Not Available

    SECTION 12 — ECOLOGICAL INFORMATION

 ECOTOXICOLOGICAL INFORMATION
   No data available.

    SECTION 13 — DISPOSAL CONSIDERATIONS

 WASTE DISPOSAL METHOD
   Waste from this product is not hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261.
   Incinerate in approved facility. Do not incinerate closed container. Dispose of in accordance with Federal, State/Provincial, and Local
       regulations regarding pollution.

    SECTION 14 — TRANSPORT INFORMATION

 US Ground (DOT)
    Not Regulated for Transportation.
 Canada (TDG)
    Not Regulated for Transportation.
 IMO
    Not Regulated for Transportation.

    SECTION 15 — REGULATORY INFORMATION

 SARA 313 (40 CFR 372.65C) SUPPLIER NOTIFICATION
 CAS No.                  CHEMICAL/COMPOUND                                                 % by WT             % Element
   No ingredients in this product are subject to SARA 313 (40 CFR 372.65C) Supplier Notification.
 CALIFORNIA PROPOSITION 65
   WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
 TSCA CERTIFICATION
   All chemicals in this product are listed, or are exempt from listing, on the TSCA Inventory.




                                                                                                                                        page 3 of 4
A32W151




   SECTION 16 — OTHER INFORMATION

   This product has been classified in accordance with the hazard criteria of the Canadian Controlled Products Regulations (CPR) and the
      MSDS contains all of the information required by the CPR.




    The above information pertains to this product as currently formulated, and is based on the information available at this time. Addition of reducers or other
    additives to this product may substantially alter the composition and hazards of the product. Since conditions of use are outside our control, we make no
    warranties, express or implied, and assume no liability in connection with any use of this information.




                                                                                                                                                         page 4 of 4

				
DOCUMENT INFO