Docstoc

SMART STAB SMART STAB

Document Sample
SMART STAB SMART STAB Powered By Docstoc
					 SMART STAB
        LM (1 Phase)
High correction speed
High efficiency
Soft start system
Smart system in order to avoid overvoltage during restart
Double overheat protection
Overload protection




 SMART STAB
        LY (3 Phase)
Independent stabilization per phase
Appropriate for balanced and unbalanced loads
High correction speed                                                                   ACE – ΠΩΛ 0122

Soft start system
Smart system in order to avoid overvoltage during restart
Double overheat protection
Voltmeter – indication lamps
Overload protection
Double overheat protection




         ACE is certified from TÜV Hellas according to EN ISO 9001 QA-Nr: 04100 30247
                                              SMART STAB LM
                                   TECHNICAL SPECIFICATIONS
POWER (KVA)                                           3,5                 5                 7,5            10           12
                      Voltage                                                        230 VAC
INPUT                 Variation                        160 - 270VAC                               160 - 260VAC
                      Frequency                                                       50 Hz
                      Voltage                                                        230 VAC
OUTPUT                Variation                                                        ±1%
                      Frequency                                                      of mains
DISTORTION            Added THD                                                       <1%
OVERLOAD                                             2 x Pnom for 1min, 5 x Pnom for 5sec, 7 x Pnom for 1sec
EFFICIENCY                                                                             >97%
TEMPERATURE                                                                        0 - 400C

                                          Transformer Overheat, Thermomagnetic internal circuit, Output interruption due to
PROTECTIONS
                                                   delayed stabilization, Soft Start, Overvoltage during start up

DIMENSIONS (mm)                                                               H: 220, L:360, W:450




                                              SMART STAB LY
                                   TECHNICAL SPECIFICATIONS
POWER (KVA)                                      7     12      15    18       22     30     36       44          60          72

                      Voltage                                                  400VAC, 3 Ph+ N
INPUT                 Variation                                                      −30, 15%
                      Frequency                                                       50Hz
                      Voltage                                                  400VAC, 3 Ph+ N
OUTPUT                Variation                                                       ±1%
                      Frequency                                                      of mains
DISTORTION            Added THD                                                       <1%
                                                                                                                                  ACE - ΠΩΛ 0122




OVERLOAD                                                2 x Pnom για 1min, 5 x Pnom για 5sec, 7 x Pnom για 1sec

EFFICIENCY                                                                            >97%

TEMPERATURE                                                                          0 - 400C

                                          Transformer Overheat, Thermomagnetic internal circuit, Output interruption due to
PROTECTIONS
                                                   delayed stabilization, Soft Start, Overvoltage during start up

DIMENSIONS (mm)                                             H: 800, W: 430, L: 530                   H: 1480, W: 820, L: 820



                                                 IDEAL FOR PROTECTION OF: