Docstoc

SLOT WALL BRACKET

Document Sample
SLOT WALL BRACKET Powered By Docstoc
					SLOT WALL BRACKET




SLOT UP AND DOWN WALL BRACKET                   For 2 fluorescent lamp TC-TEL 26/32/42W Gx24q-3/4             Art.S.3945

SLOT UP AND DOWN WALL BRACKET                   For 2 metal halide lamp HIT-CRI 70W G12                      Art.S.3946                    03



SLOT UP AND DOWN WALL BRACKET                   For 2 metal halide lamp HIT-CRI 150W G12                     Art.S.3948           (Ta=15°C)

SLOT DOWN WALL BRACKET                          For 2 fluorescent lamp TC-TEL 26/32/42W Gx24q-3/4            Art.S.3935
                                                                                                                                           03
SLOT DOWN WALL BRACKET                          For 2 metal halide lamp HIT-CRI 70W G12                      Art.S.3936
                                                                                                                                           03
SLOT DOWN WALL BRACKET                          For 2 metal halide lamp HIT-CRI 150W G12                     Art.S.3938

N.B.: USE UV STOP LAMPS ONLY

TECHNICAL INFORMATION

 Body in die-cast/extruded aluminium.                                                               Minimum distance between fitting and
                                                                                            0,5 m   lighted surface = 0,5m
 Tempered glass diffuser.
 Stainless steel screws.
 Pre-phosphochromatation treatment and powder paint with high corrosion resistance.
 Lampholders in compliance with European Standards.
 Cable connection with fast-in system.
 Pre-wired for double switch-on.
 CLASS I        IP 65
INSTALLATION INSTRUCTION

 Remove the fixation plate (A) unscrewing the screws (B).
 Open the fitting and remove rings and glassess (C).
 Install the fixation plate to the wall with 3 screws (not supplied) following drawing 1.
 Connect the supply cable (Ømin=9mm - Ømax=10mm) to the power point connector (supplied) following the scheme.
           1=LIFE FOR DOWN LAMP                 2=LIFE FOR UPPER LAMP (only for S.3946 and for S.3948)  3=NEUTRAL
 Connect the power point connector with the plug connector (pre-installed on the fitting).
 Insert the fitting on the fixation plate and lock the screws (B).
 Insert the correct lamps and adjust the reflectors as on your request (+/- 20°).
 Close the fitting re-installing glasses and rings (C)..
RECOMMENDATIONS

 Do not exceed the maximum wattage-see internal label.
 The fitting must be earthed.
 Disconnect the power before maintenance.
 Use          HAR          cable.
 In case of glass damage, replace it before using the fitting.
 Do not enter with single wires into the power point connector.
NOTE
        The fitting is suitable to the mounting on normal flammable surfaces.

 Installation should be carried out by a suitably qualified person in accordance with good
 electrical practice and the appropriate national wiring regulations.

 Is very important to follow these instructions to, enable the fitting to be installed correctly.
 Please retain for information.                                                                             ISTRSLOTPARE REV.3 06/02
SLOT / MINISLOT / MICROSLOT ACCESSORIES
                                                                                                                        RING
                       RING                                               RING
                                                                         GLASS                                          GLASS +
                       GLASS                                              ACCESSORY                                     ACCESSORY




                       GLASS                                              ACCESSORY                                     GLASS +
                                                                                                                        ACCESSORY
                                                                          GLASS
                       RING                                               RING
                                                                                                                        RING
                       Pic. A                                      Pic. B                           Pic. C

SLOT ACCESSORY

 EXTENSIVE LENS                                                    Art. S.3901
 ELLIPSOIDAL LENS                                                  Art. S.3902
 RED FILTER                                                        Art. S.3906
 BLUE FILTER                                                       Art. S.3907
 YELLOW FILTER                                                     Art. S.3908
 GREEN FILTER                                                      Art. S.3909

MINISLOT ACCESSORY

 EXTENSIVE LENS                                                    Art. S.3911
 ELLIPSOIDAL LENS                                                  Art. S.3912
 RED FILTER                                                        Art. S.3916
 BLUE FILTER                                                       Art. S.3917
 YELLOW FILTER                                                     Art. S.3918
 GREEN FILTER                                                      Art. S.3919

MICROSLOT ACCESSORY

 EXTENSIVE LENS                                                    Art. S.3991
 ELLIPSOIDAL LENS                                                  Art. S.3992
 RED FILTER                                                        Art. S.3996
 BLUE FILTER                                                       Art. S.3997
 YELLOW FILTER                                                     Art. S.3998
 GREEN FILTER                                                      Art. S.3999

 Tempered glass diffuser

INSTALLATION INSTRUCTIONS

 Open the fitting and remove the ring and the glass (Pic. A).
 Place the accessory in the seat of the gasket (Pic. B).
 Install glass + accessory leaving the accessory in the internal side of fitting (Pic. C).
 Close the fitting.

REMARKS

 Disconnect the power before maintenance.
 In case of glass damage, replace it before using the fitting.

 Is very important to follow these instructions to, enable the fitting to be installed correctly.
 Please retain for information.