Docstoc

EMO MICROPHONE COMBINERS INSTRUCTIONS FOR USE

Document Sample
EMO MICROPHONE COMBINERS INSTRUCTIONS FOR USE Powered By Docstoc
					                                                                   EMO MICROPHONE COMBINERS
                                                                         INSTRUCTIONS FOR USE

  CAUTION: UNDER NO CIRCUMSTANCES CONNECT THESE PRODUCTS TO ANY MAINS POWER SUPPLY.

  Models
           E345 SINGLE MICROPHONE SPLITTER (20-345)




  Can be modified to pass phantom power to input

  Outputs/Connections
  XLR type are connectors wired to IEC-268 Part 12 and BS5428 Part 5/3.

         Pin 1 – Gnd/Earth/0V
         Pin 2 – Signal positive/hot
         Pin 3 – Signal negative/cold

  E.M.O. Microphone Combiners combine two microphone level inputs to one microphone level output. Outputs A and B are
  transformer isolated from the input. The Direct Output is connected in parallel with the input XLR.

  Phantom Powering
  As standard, the unit will not pass phantom power to any of the inputs from the output. Although the unit leaves the fac-
  tory in this form, it is possible to allow this unit to pass phantom power from the output to one or both of the inputs. This
  is achieved by moving the header plugs adjacent to the “A” XLR (within the unit) to the desired settings. When the header
  plugs are placed on the two outer connections, the phantom is disabled. Swap the plug to the inner that is marked “A“ or
  “B” (on the rear of the p.c.b.) to allow phantom to be passed to “A” or “B”.

  Phase Reverse
  The phase reverse switch may be used by systems that may require a differential signal from a closely matched pair of
  microphones e.g. in public address noise cancellation scenarios.

  Technical Specification
  Frequency response:       20Hz to 20kHz +/- 0.25dB
  Input Level:              Maximum of +4dBm at 30Hz


  For further information or servicing please contact your local E.M.O. Dealer.




E.M.O. Systems, Crowther Road, Washington, NE38 0BW, UK. (Tel:+44 (0)191 418 1000), www.emosystems.co.uk
Our Policy is one of continuous development: all specifications and design details are subject to change without notice.           1

				