									                                 CITY OF LAKE FOREST
                               SPECIFICATIONS FOR A
         HEIL DUMP BODY, SNO-KING TRIP EDGE SNOW PLOW, SWENSON SPREADER
               & COMPONENT TECHNOLOGY CENTRAL HYDRAULIC SYSTEM

COMPLIANCE TO SPECIFICATIONS: The bidder shall indicate their compliance by checking "Yes" or
"No" for each item specified. Any space not checked shall be interpreted as non-compliance and will result in
disqualification of the bid. If "No" is checked, then the bidder must include a detailed type description of each
exception with an explanation on the enclosed exception page.

BODY SPECIFICATIONS:                                                                  MEET SPECIFICATIONS

MAKE & MODEL:

HEIL MODEL LESI-1034 DURAMAX DUMP BODY - "NO EXCEPTIONS"                                  YES____ NO____

DIMENSIONS:

10’ long                                                                                   YES____    NO____
84‖ inside width                                                                           YES____    NO____
96‖ outside width                                                                          YES____    NO____
38‖ high front bulkhead                                                                    YES____    NO____
14" high sides                                                                             YES____    NO____
20" high tailgate                                                                          YES____    NO____
3 yard capacity sides                                                                      YES____    NO____
4 yard capacity ends                                                                       YES____    NO____

MATERIAL:

Sides - 10 gauge Hi-Ten steel                                                              YES____    NO____
Front Head - 10 gauge. Hi-Ten steel                                                        YES____    NO____
Tailgate - 10 gauge Hi-Ten steel                                                           YES____    NO____
Floor - 3/16" Hi-Ten steel                                                                 YES____    NO____
Understructure - Crossmemberless                                                           YES____    NO____
           Two deep flared longitudinals                                                   YES____    NO____
            8‖ fully boxed                                                                 YES____    NO____
           ―I-beam lonitudinals not acceptable‖                                            YES____    NO____
Longitudinals - 3/16‖ Hi-Ten steel                                                         YES____    NO____
Front Corner Post - 10 gauge Hi-Ten steel                                                  YES____    NO____
Rear Corner Post - 10 gauge Hi-Ten steel                                                   YES____    NO____
Rear Apron - 10 gauge Hi-Ten steel                                                         YES____    NO____

SIDES:

Sides constructed of 10 gauge Hi-Ten steel                                                 YES____ NO____




                                                         1
BODY SPECIFICATIONS:                                                                      MEET SPECIFICATIONS

SIDES:

All exposed bends to be 1‖ radius                                                            YES____   NO____
Front corner post to be 3‖ deep and to have an aerodynamic design.                           YES____   NO____
―No side braces permitted‖                                                                   YES____   NO____
Top rail to be box section 3-3/4‖ wide x 5-1/2‖ tall                                         YES____   NO____
Top rail section to be enclosed with flanged formed into floor bevel plate for a             YES____   NO____
 ―double wall‖ construction.
Top rail centerbend to fold back at 20 degrees at top and bottom to bend back at             YES____ NO____
 35 degrees from horizontal.
No seams visible to outside or bottom of top rail.                                           YES____ NO____

TAILGATE:

Tailgate constructed of 10 gauge Hi-Ten steel                                                YES____   NO____
All horizontal bracing, including top rail, to be dirt shedding using large radius die.      YES____   NO____
―No center vertical braces‖                                                                  YES____   NO____
Minimum 1/2‖ flame cut offset upper tailgate hinge                                           YES____   NO____
Quick release upper tailgate pins by using the unique helical grooved operating              YES____   NO____
 device.
Device operates by turning the interlocking lever to withdraw the pins on each side          YES____ NO____
 from there normal operating position to lower tailgate.
Like wise to return the tailgate to the closed position, just rotate the lever to            YES____ NO____
 reposition the pin and lock it into place.
―Single lever in middle of tailgate not acceptable‖                                          YES____ NO____
Minimum 3/4‖ lower tailgate pin incorporated in lower vertical tailgate brace for            YES____ NO____
 added strength.
Minimum 1/4‖ diameter proof coil spreader chains                                             YES____   NO____
1/2‖ lower latch assembly                                                                    YES____   NO____
1/2‖ plate flame cut lower pin cradle                                                        YES____   NO____
Complete tailgate latching assembly reinforced with a 1/4‖ backing plate for                 YES____   NO____
 added strength.
100% fully solid welded construction                                                         YES____ NO____

FRONT HEAD:

Front head constructed of 10 gauge Hi-Ten steel                                              YES____ NO____
1/4 cab shield to be integral part of front head panel.                                      YES____ NO____
"Weld on cab shields not acceptable."                                                        YES____ NO____

FLOOR:

Floor constructed of 3/16‖ Hi-Ten steel                                                      YES____ NO____
84‖ inside width                                                                             YES____ NO____
Bevel plates floor to side bracing incorporated in top rail                                  YES____ NO____



                                                              2
BODY SPECIFICATIONS:                                                                    MEET SPECIFICATIONS

SUB-FRAME:

Crossmemberless                                                                            YES____ NO____
―Crossmembers not acceptable‖                                                              YES____ NO____
Two deep flared longitudinals fabricated of 3/16‖ Hi-Ten steel and are                     YES____ NO____
 8‖ fully boxed.
―I-beam or C-Channel longitudinals are not acceptable‖                                     YES____ NO____

PAINT:

Body painted one color to match cab.                                                       YES____ NO____

HOIST:

HEIL MODEL LESI-1520-SF DURAMAX HOIST - "NO EXCEPTIONS"                                    YES____ NO____

Single cylinder dual support scissor hoist                                                 YES____   NO____
―Direct lift or telescopic hoist unacceptable‖                                             YES____   NO____
NTEA class 40 Type I                                                                       YES____   NO____
Rating of 16.7 tons capacity                                                               YES____   NO____
Double acting                                                                              YES____   NO____
Power up-power down                                                                        YES____   NO____
5‖ diameter cylinder                                                                       YES____   NO____
20‖ Stroke                                                                                 YES____   NO____
Vickers DPH900-1100 chrome plated piston cylinder                                          YES____   NO____
Full length formed subframe                                                                YES____   NO____
Safety body prop                                                                           YES____   NO____
50 degree dump angle                                                                       YES____   NO____

DUMP BODY OPTIONS SPECIFICATIONS:                                                       MEET SPECIFICATIONS

Lindco Model 2430PHD mud flaps mounted behind rear wheels.                                 YES____ NO____
Koneta black polymer splash guards frame mounted in front of rear wheels.                  YES____ NO____
Removable 30‖ stakes down each side & in the rear of the body.                             YES____ NO____

LIGHTING AND WIRING SPECIFICATIONS:                                                     MEET SPECIFICATIONS

Heil electronic back up alarm                                                              YES____   NO____
All LED Lights and reflectors conform to FMVSS108                                          YES____   NO____
LED Stop, tail & turn lights recessed in rear corner post                                  YES____   NO____
Truck-Lite Model 60122Y amber LED strobes with grommet and pigtail                         YES____   NO____
recessed in the following areas on each side:
One (1) set recessed in boxes on each rear corner post for a total of two (2) lights.      YES____   NO____
All strobes must be boxed in on their back sides.                                          YES____   NO____
Velvac Model 055052 trailer plug mounted at rear.                                          YES____   NO____
Electric brake controller mounted in cab.                                                  YES____   NO____
LESI or approved equal Sealed Wiring System                                                YES____   NO____
Velvac Model 055060 weather tight junction box mounted at rear of truck.                   YES____   NO____
                                                           3
LIGHTING AND WIRING SPECIFICATIONS:                                                    MEET SPECIFICATIONS

All bolts, washers, nuts and screws must be stainless                                     YES____   NO____
All wiring will be one piece                                                              YES____   NO____
All connections will terminate in the rear junction box for all add on lighting           YES____   NO____
Seven wire sealed trailer harness from cab junction box to rear corner junction box.      YES____   NO____
All connections into rear junction box will have electrical eyelet connectors             YES____   NO____
 soldered to them.
All electrical connections done by equipment installer must be soldered and               YES____ NO____
 heat shrinked.
TST Model 131-0011 High Amp Breaker, Type III switchable breaker, flush                   YES____ NO____
mounted on truck firewall.
Grote 64931 spreader light mounted on drivers side rear                                   YES____ NO____
Body up light                                                                             YES____ NO____

TRAILER HITCH AND OTHER ITEMS SPECIFICATIONS:                                          MEET SPECIFICATIONS

5/8‖ pintle plate with two (2) B46, 3/4" ―D‖ rings.                                       YES____   NO____
PH20, 20 ton capacity pintle hook                                                         YES____   NO____
Plate must be recessed into the frame rails with gussets to frame on the backside.        YES____   NO____
Chassis S/T/T lights mounted on each side of pintle plate                                 YES____   NO____
Buyers Model B2800A front tow hooks                                                       YES____   NO____
Buyers Model B2800A rear tow hooks                                                        YES____   NO____

CENTRAL HYDRAULIC SYSTEM SPECIFICATIONS:                                               MEET SPECIFICATIONS

Pump Mounting Kit:

Pump to be mounted to engine with factory style brackets and steel machined pulleys       YES____ NO____
designed for a particular truck make and model and engine size.
Kit to be complete with all spacers, bolts, pulleys and brackets (idler if required)      YES____ NO____
necessary for factory style installation.
Mount kit to have ―A‖ mount pilot as part of factory bracket.                             YES____ NO____
Cast Aluminum mounting brackets acceptable for Isuzu diesel.                              YES____ NO____

C.W. MILLS EQUIPMENT INC. COMPANY MODELS – “NO EXCEPTIONS”                                YES____ NO____

Hydraulic Gear Pump:

Pump shall be of the cast iron gear design.                                               YES____ NO____
Pump shall be capable of 12-20 GPM and 3000 PSI at 2000 RPM.                              YES____ NO____
Unit shall have internal Teflon coated brass wear plates, and heavy-duty internal         YES____ NO____
 journal bushings.
Pump shall be capable of mounting directly to clutch via tapered shaft and bracket.       YES____ NO____
Clutch shall be a minimum of 90 foot-pounds and be activated by a lighted rocker          YES____ NO____
 switch mounted in the dash.
Electric clutch shall be an 8-groove serpentine design.                                   YES____   NO____
Pump body shall be a 3 section bolt-together body.                                        YES____   NO____
2 piece or aluminum pumps are not acceptable.                                             YES____   NO____
Commercial Intertech P315 series no exceptions.                                           YES____   NO____
                                                         4
CENTRAL HYDRAULIC SYSTEM SPECIFICATIONS:                                             MEET SPECIFICATIONS

Hydraulic Control Valve:

The valve shall be no more than 14.5 inches in length and will include the Hoist,       YES____ NO____
Plow and Spreader functions.
The Hoist and Plow valves will consist of ―Bolt-On‖ directional elements.               YES____   NO____
Each directional element will include an adjustable ―Meter-In‖ flow control.            YES____   NO____
The Spreader valves will be proportional cartridge type.                                YES____   NO____
All valve components shall be removed from the manifold without disturbing the          YES____   NO____
plumbing.
The manifold will allow for sealed mounting to a valve enclosure plate.                 YES____   NO____
All ports will be thru the mounting plate side of the manifold.                         YES____   NO____
The Inlet and Auger ports will be #12 SAE. The Tank port will be #16 SAE.               YES____   NO____
The Hoist and Spinner ports will be #10 SAE.                                            YES____   NO____
The Plow ports will be #8 SAE.                                                          YES____   NO____
All ports will allow the use of standard ORB to JIC fittings.                           YES____   NO____
The manifold will include a pilot controlled inlet un-loader for open center use.       YES____   NO____
The valve can provide a ―power beyond‖ option.                                          YES____   NO____
The power beyond option will be field convertible by adding a plug.                     YES____   NO____

The valve functions will include:

Section 1:
Hoist Up/Down, 3 position – 4 way, (3 way optional) solenoid operated, manual           YES____ NO____
override, 500 PSI ―A‖ port relief on down side and sub plate mounted. The Hoist
function will be rated a nominal flow of 30 GPM.
Section 2:
Plow Up/Down, 3 position – 3 way, (4 way optional) solenoid operated, manual            YES____ NO____
override, 2000 PSI ―B‖ port relief on up side, sub plate mounted. The plow
functions will be rated a nominal flow of 12 GPM. (Solenoid operated, manual
override, zero leakage poppet holding valve with Plow float capabilities optional)
Section 3:
Plow Left/Right, 3-postion – 4 way, solenoid operated, manual override and sub          YES____ NO____
plate mounted. The plow functions will be rated a nominal flow of 12 GPM.
(Crossover relief optional)
Section 4:
Auger Speed, proportional electrical, pressure compensated flow control. 0-16           YES____ NO____
GPM flow range with manual override.
Section 5:
Spinner Speed, proportional electrical, pressure compensated flow control.              YES____ NO____
0-16 GPM flow range with manual override.
All Coils 12VDC encapsulated with DIN 43650 connections.                                YES____ NO____
Main relief to be pilot operated nominally rated for 30 GPM and 3500 PSI.               YES____ NO____

COMPONENT TECHNOLOGY MODEL SG04090021 – “NO EXCEPTIONS”                                 YES____ NO____




                                                        5
CENTRAL HYDRAULIC SYSTEM SPECIFICATIONS:                                           MEET SPECIFICATIONS

Hydraulic Reservoir:

Reservoir shall be 15-gallon minimum capacity with the breather cap mounted             YES____ NO____
 to an inspection lid.
Inspection lid shall also provide for an in tank mounted return line filter.            YES____   NO____
Return filter shall be capable of 30 GPM and have a 10 micron element.                  YES____   NO____
Return filter must have a 1‖ NPT port and come with a filter condition gauge.           YES____   NO____
Breather cap fill neck must be screened.                                                YES____   NO____
Reservoir shall be complete with a sight temperature gauge and a magnetic drain         YES____   NO____
 plug.
Suction port will allow for installation of a 1 ¼‖ NPT 25 GPM suction screen.           YES____   NO____
Suction screen will have a 3 to 5 PSI by-pass spring.                                   YES____   NO____
Reservoir must be constructed of ―304‖ Stainless Steel.                                 YES____   NO____
As an integral part of the reservoir, there shall be an area for mounting of the        YES____   NO____
 hydraulic stack valve.
Valve must be sealed from the weather and have a removable lid for inspection           YES____ NO____
 while the dump body is in the lowered position.
Hose connections shall be made via bulkhead connectors on the bottom side of            YES____ NO____
 the reservoir.
Reservoir must be capable of mounting on either side of the truck frame.                YES____ NO____

COMPONENT TECHNOLOGY MODEL SG03060016 – “NO EXCEPTIONS”                                 YES____ NO____

SPREADER CONTROL SYSTEM:

STORMGUARD MODEL AS3 - "NO EXCEPTIONS"                                                  YES____ NO____

CONTROL SYSTEM:

STORMGUARD MODEL SG10 STAND ALONE SYSTEM- "NO EXCEPTIONS" YES____ NO____

WIRING HARNESSES:

The system shall include all necessary wiring and switching required to be fully        YES____ NO____
operational.
All wiring that will be exposed outside the vehicle cab shall be of weatherproof        YES____ NO____
TPE type.
Wiring and harness system should meet ISO rating IP68 and NEMA 6.                       YES____ NO____
The connectors should be zinc die cast E-coated, similar to a MIL spec connector.       YES____ NO____
Each should have three sealing points- the lock ring itself, a raised portion of the    YES____ NO____
molded plastic around each pin, and a viton O-ring that seals the whole connector.
The cable jacket should be TPE- thermoplastic elastomer, and molded to the              YES____ NO____
connectors. Connectors and harness should be rated and tested for a temperature range
from – 30C to + 70C.
Connectors should be tested to be water tight when submerged in 6’ of water for 24      YES____ NO____
hours, in 275’ of water for 1 hour, and when subjected to a 1000-psi pressure wash.


                                                        6
CENTRAL HYDRAULIC SYSTEM SPECIFICATIONS:                                                MEET SPECIFICATIONS

WIRING HARNESSES:

The connectors should be designed to have NO corrosion after 5000 hours in a                 YES____ NO____
35C salt spray.
Cabling should be rated excellent in its resistance to oxidation, heat, oil, low             YES____ NO____
temperature flexibility, weather, sun, ozone, abrasion, electrical priorities, flame,
water, acid, alkali, gasoline, benzol, toluol, degreaser solvents, alcohol, and weld slag.
Harnesses to include all necessary sensors and cables.                                       YES____ NO____

STORMGUARD TPE WIRING - "NO EXCEPTIONS"                                                      YES____ NO____

WIRING, HOSES AND FITTINGS:

LINDCO MODEL TMLS-5B-SV HOSE & FITTING KIT.                                                  YES____ NO____

All fittings must be JIC hydraulic fittings.                                                 YES____ NO____
―Pipe fittings not acceptable.‖                                                              YES____ NO____
All hydraulic hoses must be protected with stainless steel hydraulic                         YES____ NO____
 hose sleeving.
This sleeving must run full length of each hose from fitting to fitting.                     YES____ NO____
All wiring will be routed in such a manner to prevent pinching and sharp corners.            YES____ NO____
All connections to valves and sensors will be made with high quality components and          YES____ NO____
 protected with dielectric grease.
All wiring of length will be tied up to prevent sagging.                                     YES____ NO____
Wire looms passing into the cab will be sealed to prevent the outside environment            YES____ NO____
 from entering the cab.
All hoses will be routed away from pinch points, areas of extreme heat and will              YES____ NO____
 be protected from sharp corners.
All necessary hoses and fittings must be included for proper operation of all                YES____ NO____
 components.
Front plow angling, lift cylinder, scraper hoses and all spreader hoses will all be          YES____ NO____
 equipped with quick couplers with dirt caps.
All spreader quick couplers will be installed through the pintle plate at the rear with      YES____ NO____
 a heavy duty steel guard above them for protection.

SNOW PLOW SPECIFICATIONS:                                                               MEET SPECIFICATIONS

SNO-KING 9’ POLYMER TRIP EDGE PLOW w/UNIVERSAL MOUNT                                         YES____ NO____
& 34” MOLDBOARD HEIGHT - “NO EXCEPTIONS”

ACCESSORIES:

Rubber snow deflector                                                                        YES____ NO____
Curb shoes                                                                                   YES____ NO____
Moldboard end markers                                                                        YES____ NO____




                                                          7
SALT SPREADER SPECIFICATIONS:                                                           MEET SPECIFICATIONS

MAKE AND MODEL:

SWENSON MODEL SADS - "NO EXCEPTIONS"                                                       YES____ NO____

GENERAL:

Spreader shall be constructed of 304 Stainless Steel                                       YES____ NO____
This under-tailgate spreader will be of bottom opening design.                             YES____ NO____
The entire unit will rigidly mount to the sides of the dump box with single pin
quick detachable hardware.                                                                 YES____ NO____
This mounting shall allow the dumping of materials without interference from
the spreader.                                                                              YES____ NO____
The overall spreader width shall not be over 96‖.                                          YES____ NO____
This unit will spread free flowing granular materials, abrasives and chemicals and
be factory adapted to accept automatic control system.                                     YES____ NO____

HOPPER:

Rigid .25‖ one piece end plates will be continuously welded to a 7 gauge auger trough.     YES____ NO____
The unit will have a 7 gauge three point hinged bottom that, when released, exposes
the entire length of the auger for easy clean out.                                         YES____ NO____
This hinged bottom shall be held in place by two heavy duty cam locks with a lift
handle for convenient one man operation.                                                   YES____ NO____
The anti—flow cover over the discharge opening is manufactured of 10 gauge steel
and removable without use of tools.                                                        YES____ NO____
The 7 gauge cover/back plate will be a one piece hinged integral part of the unit
which may be raised when spreading and lowered when dumping.                               YES____ NO____
This cover shall be capable of being locked in either the raised or lowered position
by two (2) simple captivated latches.                                                      YES____ NO____

FEED MECHANISM:

The six (6) inch (nominal) heavy duty auger shall consist of 3/8‖ flighting which is
welded to a 2‖ ERW pipe size tube.                                                         YES____ NO____
This auger shall have continuous and reverse flighting to the discharge port for more
uniform dump body emptying and shall be supported by 1.25‖ shafting ends.                  YES____ NO____
The auger shafts will be supported in sealed, self-aligning precision single row
radial bearing with grease fittings.                                                       YES____ NO____
The drive end bearing shall attach to a removable 7 gauge end plate.                       YES____ NO____
The discharge port shall be located on the left side of the trough.                        YES____ NO____

SPINNER:

The spinner shall consist of a disc and six (6) vanes formed into a single polyurethane
unit, resulting in a flat trajectory and a uniform spreading pattern from four (4) to
forty (40) feet.                                                                           YES____ NO____
The spinner assembly shall be adjustable allowing for variable spreading pattern left,
center or right.                                                                           YES____ NO____
                                                         8
SALT SPREADER SPECIFICATIONS:                                                         MEET SPECIFICATIONS

SPINNER:

This will be accomplished by sliding the hinged frame sideways on the shaft so that
the point at which the material hits the spinner disc is varied.                         YES____ NO____
The entire spinner assembly shall be easily removed by pulling two pins and
uncoupling two hydraulic ―quick disconnects‖ hoses.                                      YES____ NO____
The spinner speed and auger feed rate shall be both variable through the dual flow
control valve located in the cab.                                                        YES____ NO____
The spinner disc will be mounted directly onto the hydraulic motor shaft by means
of a cast iron spinner hub.                                                              YES____ NO____
The spinner assembly will be linked to the truck frame with a universally mounted
parallel arm to keep the spinner horizontal to the road at all dump box angles.          YES____ NO____
A spinner shield shall be provided to prevent material from striking the truck.          YES____ NO____

POWER TRAIN:

There shall be two separate hydraulic ―orbital type‖ motors capable of delivering high
torque at low speeds to power both the spinner and the auger.                            YES____ NO____
The independent spinner motor shall mount directly to the spinner disc eliminating any
power loss by transmission.                                                              YES____ NO____
The auger shall be driven by a direct drive hydraulic motor coupled to the auger.        YES____ NO____
The hydraulic motor will mount directly into the auger pipe by a non-corrosive
sleeve and a .5‖ grade 5 bolt.                                                           YES____ NO____
The hydraulic motor shall mount directly to the end plate.                               YES____ NO____

PAINTING:

All metal parts shall be millscale and oil removed by means of a high pressure
chemical cleaner prior to painting.                                                      YES____   NO____
These surfaces will be primed with a rust preventative primer.                           YES____   NO____
The paint will be a high quality, high solid, lead free Enamel.                          YES____   NO____
All painting shall be done in conjunction with good commercial practice.                 YES____   NO____

MOUNTING:

This spreader shall fasten to the side of the dump body using quick disconnect pins
for quick mounting and removal of spreader without use of special tools.                 YES____ NO____

LIFTGATE SPECIFICATIONS:                                                              MEET SPECIFICATIONS

TOMMYGATE MODEL 86-1650 LD TP DUMP THROUGH LIFTGATE                                      YES____ NO____

Tommy Gate 1600 lbs. Dump Body Liftgate, 83" W x 34" D Treadplate Platform,
Electric Hydraulics w/ Curbside Controls painted black.                                  YES____ NO____
Unit to be bolted to body for ease of removal.                                           YES____ NO____



                                                        9
SPECIAL EQUIPMENT SPECIFICATION NOTES:                                                MEET SPECIFICATIONS

DUE TO NEEDING SERVICE AND/OR PARTS ON VEHICLES AND/OR
EQUIPMENTS DURING A SNOW STORM OR ANY OTHER EMERGENCY
SITUATION THE CITY OF LAKE FOREST IS REQUESTING
THAT THE FOLLOWING ITEMS BE MET!

No alternate or optional quotes/bids on equipment will be accepted!                       YES____ NO____
Furnishing of an alternate or optional quote/bid will disqualify the entire bid!

Equipment contractor must be a factory authorized distributor for all equipment           YES____ NO____
furnished.

The equipment company must have a 24 hour emergency phone hot line for parts              YES____ NO____
during a snow storm.

A letter from the equipment dealer stating all warranties must be furnished in writing    YES____ NO____
at time of bid, for bid to be considered.

There will be a pre-construction meeting with the equipment installer at time of          YES____ NO____
chassis arrival to their facility.

There will be a final inspection with the equipment installer, within three weeks after   YES____ NO____
pre-construction meeting.

The same equipment company must furnish all equipment for the unit.                       YES____ NO____

Literature and parts manuals must be furnished on the following:                          YES___    NO____
Body & Hoist                                                                              YES____   NO____
Snow Plow                                                                                 YES____   NO____
Hydraulic Components                                                                      YES____   NO____
Equipment Warranty Letter                                                                 YES____   NO____

All requested items must be furnished with bid, for bid to be considered.                 YES____ NO____




                                                          10
                      Exceptions to Requested Bid Specifications
This Page must be filled out with a detailed list of exceptions to all items that you have checked ―NO‖ for
MEETING SPECIFICATIONS. Please make copies of this page and insert them into the bid, if more pages are
needed to list these items.

SPECIFICATION ITEM                        PAGE NUMBER                         EXCEPTION

___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
                                                    11
                          CITY OF LAKE FOREST
                               BID RESPONSE FORM
           COMPANY NAME:________________________________________________

           ADDRESS:_____________________________________________________

           CITY:_______________________ STATE:_____ ZIP CODE:___________

           PHONE NUMBER:_________________ FAX NUMBER:___________________

           PERSON EXECUTING THE CONTRACT:______________________________

           TITLE:_______________________________________________________



PRICE PER UNIT FOR REQUESTED EQUIPMENT:                          $___________

OPTION FOR 304 STAINLESS STEEL DUMP BODY, INCLUDING THE
FLOOR & TAILGATE HARDWARE. LONGMEMBERS WILL BE
CONSTRUCTED OF 3/16" COR-TEN STEEL:                              $___________

OPTION FOR COMPONENT TECHNOLOGY GL-400 SPREADER
CONTROL IN LIEU OF AS3:                                          $___________

NUMBER OF DAYS FOR COMPLETED UNIT TO BE DELIVERED TO THE CITY OF LAKE
FOREST, AFTER RECEIVING PURCHASE ORDER: ______ DAYS


SIGNATURE OF BIDDER:_____________________________ DATE:_________________

TITLE:___________________________________________

THE ABOVE AGREES TO HOLD THE ABOVE PRICING FOR NINETY (90) DAYS.