; Product Dimensions - SOLAR LOLINE ELECTRIC BOOST 511340 _WITH
Documents
Resources
Learning Center
Upload
Plans & pricing Sign in
Sign Out
Your Federal Quarterly Tax Payments are due April 15th Get Help Now >>

Product Dimensions - SOLAR LOLINE ELECTRIC BOOST 511340 _WITH

VIEWS: 44 PAGES: 1

  • pg 1
									                                                                                         PIPE LENGTHS:
                                                                                                                                                                                                                         Solar Water Heater Aspect
                                                                                         The maximum recommended combined length of the solar cold and solar                                                                Southern Hemisphere
                                          INDOOR AND                                     hot pipes between the solar storage tank and solar collectors with bends is:
                                        OUTDOOR MODEL                                                                                                                                                                                 NORTH
                                                                                                  Maximum recommended pipe length and number of 90° bends                                               *                                       Recommended
                                                                                                                                                                                                                  would be reduced                     aspect
                                                                                                                      1 or 2 Collectors                                          3 Collectors                     approx 5% at N.E.
                                                 Rheem
                                                                                                 Pipe size                                                                                                        and N.W. point
                                                                                                                 Pipe Length           90° Bends                   Pipe Length              90° Bends
HOT WATER
                                                                                                                                                                                                                               NW                    NE
OUTLET                                                                                              DN15         40 metres                      20                 30 metres                    20
                                            RHEEM
                                            511340                                                  DN20              NR                        NR                 40 metres                    20
                                                                                                                                                                                                                                      45° 45°
                             T&PR
                             VALVE                                                                * For each additional 90° bend, reduce the maximum total pipe
                                                                                                                                                                                                                         W                                E
                                                                                                   length by 0.5 metres.
                                                                                                  * For each additional metre of pipe length, reduce the number of
                   1640
                          1357                                 ELECTRICAL                          90° bends by two.
                                                               CABLE ENTRY                        * Note: One 90° elbow is equal to two 90° bends.
SOLAR HOT
(FROM COLLECTOR)                                                                            LEGEND




                                                                                                                                                                                                                                                                511340 NPT200 With Collectors From 2007/06 Manufacture REV-AD (A3)
                                                                                                                                                                                        0
                                                                                                                                                                                     210
INLET                                                                                            STOP COCK                                                                                                                               S
                                  561                                                            NON RETURN VALVE
                                                                  623
                                                                                                 DUAL CHECK VALVE
COLD WATER                                                              SOLAR COLD               PRESSURE LIMITING VALVE (IF REQUIRED)
INLET                                                                   (TO COLLECTOR)
                                                                73                               COLD WATER RELIEF VALVE (IF REQUIRED)
                            73                                          OUTLET
                                                                                                 UNION
                                             Ø638
                                                                                                 CIRCULATOR                                                                193
                                                                                           SNR
                                                                                                                                                                                 7
                                                                                                 SOLAR NON RETURN VALVE
                                            RHEEM                                                BLEED VALVE
                                            511340                                                                                                                                                          HOT WATER FLOW
                                                                                                 DIRECTION OF FLOW
                                                                  678
                                                                                                 TUNDISH
                                 32°
                                                                                           HOT WATER CONNECTION:- RP               3
                                                                                                                                       4 /20.
                                                                                                                                                                                                                              Rheem




                                                                                           COLD WATER CONNECTION:- RP                  3
                                                                                                                                           4 /20.
                                  880
                                                                                           SOLAR HOT (FROM COLLECTOR) CONNECTION:-
                                                         320                               DN15 COMPRESSION FITTING.                                                                                                       RHEEM
                                                                                           (SOLAR HOT WATER INLET TO TANK: RP                        3
                                                                                                                                                         4 /20).
                                                                                                                                                                                                                           511340
       NOTES:
       N1. SOLAR COLLECTORS MUST BE INSTALLED                                              SOLAR COLD (TO COLLECTOR) CONNECTION:-
         - ORIENTATED TOWARD THE EQUATOR                                                   DN15 COMPRESSION FITTING.
                                                                                           (SOLAR COLD WATER OUTLET FROM TANK: RP                                  3
         - WITH AN ANGLE OF INCLINATION EQUAL                                                                                                                          4 /20).                              SNR
          TO THE LOCAL LATITUDE ANGLE, BUT NOT                                                                                         1
           LESS THAN 10°.                                                                  T&PR VALVE CONNECTION:- RP                   2   /15.
         - IN A POSITION FREE OF SHADE.                                                                                                                                COLD WATER
                                                                                           STORAGE VOLUME:- 325 LITRES.
       N2. A MINIMUM OF 900mm SHOULD BE LEFT                                                                                                                            INLET PIPE
         IN FRONT OF THE SOLAR STORAGE TANK                                                BOOST VOLUME:- 200 LITRES.
         FOR ACCESS, SERVICING AND SOLAR STORAGE
         TANK REMOVAL.                                                 RHEEM WATER HEATERS
                                                                 SOLAR LOLINE ELECTRIC BOOST 511340
                                                                 (WITH 2xNPT 200 SOLAR COLLECTORS)

								