					Safety light barrier                                      SMB series
single beam
Type 4 according EN61496
Multiple beams




         EC type examination certificate




Ideals for protection of                   SMB choice
•   Access                                 •   Safety outputs by 2 integrated relays
•   Access with muting                     •   Very short response time
•   Perimeter                              •   Very improtant signal margin
                                           •   Automatic or manual restart
                                           •   EDM function integrated
Few applications • • •                     •   TEST function integrated
On machines such as:                       •   Power supply:
•   palettiser and depalettiser                24, 48, 110, 230 VAC or 24 VDC
•   assembler                              •   Laser tool for mechanical alignment
•   welding                                •   Very large range of accessories:
                                               posts, mirrors…




                                                                                ET224C
                                                                                       0403
     JAYSENSOR
TECHNICAL CHARACTERISTICS
Detection characteristics                                                                          Operating caracteristics
•   Range 0 to 40 m.                                                                               •    Protection function:
•   Smallest detectable object = 27 mm.                                                                 The NO contacts open when the beam is obstructed.
•   Beam divergergence: ≤ ± 2°.                                                                         Response time after the beam obstruction: 0,015s
•   Immunity against ambient light up to 30 000 lux.                                               •    Restart after beam obstructed and restored:
                                                                                                        2 types of receivers:
Mechanical and climatic caracteristics                                                                  • automatic restart (SMBC 5A*model) the contacts
•   Aluminium housing IP 65.                                                                            close after the beam has been restored. (closing
•   Mounting with T grooves on housing sides.                                                           time: 0,1s)
•   Plug in connectors.                                                                                 • start interlock (SMBC 5B*model) (on power
•   Screw terminal connectors.                                                                          switched ON) and restart interlock (after beam
•   Operating temperature: - 20°C to 50°C.                                                              restored), this function is also known as « manual
•   Weight: emitter SMBT        : 1.6 kg                                                                restart ». After obstructing then reestablishing the
               receiver SMBR : 1,75 kg                                                                  beam, the NO contacts stay open. We must then
                                                                                                        shortcircuit momentarily the 2 pins (for example with a
Electrical characteristics                                                                              push-button) to restart, that means closing the 2
Power supply                                                                                            output contacts (response time: 0,05s after releasing
• 24, 48, 110 or 230VAC +10 %, - 20%                                                                    the push-button).
• 24VDC ± 20%                                                                                      •    Periodical test function (test) : simulates a beam
• Maximum consumption (for emitter + receiver):                                                         obstruction (intrusion):
   6VA (AC) ou 130mA (DC).                                                                              • function done by the opening of a link between 2
Outputs                                                                                                 pins in the emitter.
• 2 safety relays with guided contacts                                                                  • the SMB is permanently self-checked (Type 4), thus
• 2 NO contacts protected by fuses (open contacts when the beam                                         the test function is not necessary. Nevertheless, this
    is broken or the equipment is not powered up)                                                       function allows a control of the whole safety stopping
•   Switching power: (on resistive load)                                                                chain of the machine.
              max.: 2A / 250VAC                                                                    •    External Device Monitoring(EDM): with the manual
              min.: 50mA/6V/6W                                                                          restart models
                                                                                                        See figure below.
Indicators: on front panel
•   Emitter : 2 LEDs
    • Power supply ON (green)
    • test (red, ON if test contact is open)
•   Receiver : 2 LEDs
                                                                 (*)
    • signal (green): ON: beam established, sufficient signal
                                                                        (*)
                        blinking: beam established, insufficient signal
    • Output (red) : ON if contacts S1 and S2 are open
    (*) in both cases, the contacts S1 and S2 are closed



WIRING DIAGRAM
            FUS
                                                                                                                                            Power supply
                                                                                                                                               circuit

                                                                                               K1                      (2)
                                                                                               (3)

                      Transmitter                                                   Receiver
                         SMBT                1                                       SMBR                    1               5
                 1
        Test                               L+                            L+                                                           K1
                     Con-                                                                                    S1              S2
                     nect.       Connector                    Connector               Connector
                     XT2           XT1                          XR1                     XR2
                                       N-                            N-                                                               K2
                 2
                                                2                           2        3         4       K1     2              6
                                                                                                       (1)
                                                                          Restart                                                            Dangerous
                                                                          (on restart                  K2         K1                  (2)
                                                                          interlock                    (1)                                  movement of
                                                                          models)                                                           the machine
                                                                                     On B model



(1) Safety feedback function: restarting is possible only if the power contactors K1 and K2 are at rest.
(2) Voltage suppressor adapted to the voltage and contactor type. Increases the life of contacts S1 and S2 and limits the interface emissions.
(3) This contactor arrangement is implemented to avoid short circuits on the safety wires. If used with a 24 VDC configuration, K1 must be connected to the common line.
INSTALLATION
•      Perimeter protection - access protection
                 Detection beams
                                                                 The European standard pr EN 999 describes the installation conditions: height
                                S                                of beams and installation distances to the danger zone.

                                                                 The risk evaluation must take into consideration all the possible accessing
                                      h3          Danger
                                                                 methods which could be used to avoid obstructing a beam, in order to
                                                   zone
                                                                 calculate the number of beams needed.
                                h2


                           h1




            Number of                     Height h (mm) of different beams                              S (mm)
             beams                                  above ground                              minimum safety distance
               4                                 300, 600, 900, 1200                        S = 1600 (0,015 + t2) + 850
               3                                    300, 700, 1100                          S = 1600 (0,015 + t2) + 850
               2                                       400, 900                             S = 1600 (0,015 + t2) + 850
               1                                          750                               S = 1600 (0,015 + t2) + 1200
          t2 = stopping time of the dangerous movements of the machine (in seconds)



APPLICATION EXAMPLES
•      Access protection
                                                                                  Product name                       Qty     Reference
                                                                                  Safety light barrier                1      SMBC 5 ••
             SMBR                                                                 Special bracket                     2      SWE 004
                                                                                  2 beam post                         2      SWP 002
                           14 m max.
                                                                                  Mirror                              2      SWMR 01
                                            900

             SMBT
                                    400




•      3 beam perimeter protection

                                                                                  Product name                       Qty     Reference
                                                    (*)
                                                   S
                                                                                  Safety light barrier                3      SMBC 5 ••
                                                                                  Special bracket                     6      SWE 004
                                                                                  3 beam post                         2      SWP 003
                                                                                  Angle Post for mirrors              1      SWP 0A3
                                                                                  Mirror                              3      SWMR 01
    SWP00*
    Post for barrier                                SWP0A*
                                                    Angle Post




Height of beams: 300, 700. 1100
(*) S max = 34 m in this arrangment of posts
For a linear protection with no angle post, S max = 22 m si the SMB is correctly aligned



•      For other application configurations, please consult your agent.
DIMENSIONS
Connectors: cable glands for cable Ø 4,5 to 7mm (Ø 4,5 to 10 for XR2)




                           Led




                                                         For frontal mounting,                                  SWE 005 bracket
                                                         turn the bracket 90°




SELECTION GUIDE: ordering references
 •       Complete light barrier: transmitter + receiver + connectors
         (brackets to be ordered separately)


                                                                  Automatic restart                                               Manual Restart
                        24 VAC                                            SMBC 5AR                                                     SMBC 5BR
                        48 VAC                                            SMBC 5AS                                                     SMBC 5BS
                       110 VAC                                            SMBC 5AT                                                     SMBC 5BT
                       230 VAC                                            SMBC 5AU                                                     SMBC 5BU
                        24 VDC                                            SMBC 5A2                                                     SMBC 5B2


 •          Adjustable brackets (to be ordered separately)
            SWE 005                             Set of 2 ajustable brackets
            SWE 004                             1 special bracket for mounting on SWP posts
                                                (order 1 bracket for the transmitter and 1 bracket for the receiver)

 •          Others accessories (to be ordered separately)
            SMW 100                             2 front mirrors for vertical mounting of the housing
            SWMR 01                             Deviation mirror
                                                              (1)
            SWP 002                             2 beam post
                                                                     (2)
            SWP 0A2                             angle 2 beam post
                                                              (1)
            SWP 003                             3 beam post
                                                                      (2)
            SWP 0A3                             Angle 3 beam post                                                                        SWA 01P

            SWA 01P                             Laser tool for mechanical alignment
                                                                                                                                                   SWA 200
            SWA 200                             Portable infrared receiver for optical alignment
               (1)                                                              (2)
                     for SMB, mirror or detector                                      with special cover with holes, for the mirrors

The products described in this document are subject to change. Descriptions and characteristics are not contractually binding.
                                                                                                                                                                     JAYSENSOR – EA354B




                                                                                                                                                       Distributor
                                                             JAYSENSOR, a factory of ASTEEL DEVELOPPEMENT
                                                             176, rue Lavoisier - Montbonnot
                                                             F - 38334 SAINT ISMIER CEDEX
                                                             TEL       : +33 (0) 476 616 590
                                                             FAX       : +33 (0) 476 616 598
              JAYSENSOR                                      E-MAIL : jaysensor@asteel.fr
                                                             WEB       : www.jaysensor.asteel.fr

				
DOCUMENT INFO