					     APPENDIX 3-VI

NOISE MODELLING METHODS
EnCana FCCL Ltd.                                                   -i-                                  Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                        Appendix 3-VI
Phases 1E, 1F and 1G                                                                                              October 2009

                                                  TABLE OF CONTENTS

SECTION                                                                                                                            PAGE

1  INTRODUCTION......................................................................................................... 1 
   1.1  NOISE TERMINOLOGY..................................................................................................2 
   1.2  NOISE LEVELS ...............................................................................................................2 
   1.3  NOISE PREDICTION METHODS ...................................................................................2 
        1.3.1   Addition of Noise Levels ..................................................................................3 
        1.3.2   Attenuation of Noise in the Environment .........................................................3 

2  NOISE MODELLING................................................................................................. 10 
   2.1  MODEL SELECTION.....................................................................................................10 
   2.2  NOISE MODELLING LIMITATIONS..............................................................................10 
   2.3  SCIENTIFIC UNCERTAINTY ........................................................................................11 
   2.4  MODEL CONFIGURATION...........................................................................................12 

3  SOURCE-SPECIFIC MODEL DATA......................................................................... 13 

4  SPECTRAL RESULTS, HUNTER/TRAPPER CABIN A ........................................... 35 

5  PERMISSIBLE SOUND LEVEL CALCULATIONS.................................................... 38 

6  REFERENCES.......................................................................................................... 40 

7  GLOSSARY .............................................................................................................. 41 

8  ABBREVIATIONS ..................................................................................................... 44 


                                                       LIST OF TABLES

Table 1              Summary of Noise Levels Associated With Common Activities..............................2 
Table 2              Noise Model Configuration Parameters.................................................................12 
Table 3              Sound Power Level at Octave Band Centre Frequency for Baseline Case
                     Outdoor Area Emission Sources ...........................................................................14 
Table 4              Sound Power Level at Octave Band Centre Frequency for Baseline Case
                     Building Sound Emission Sources.........................................................................14 
Table 5              Sound Power Level at Octave Band Centre Frequency for Sulphur
                     Recovery Facility Sound Emission Sources ..........................................................21 
Table 6              Sound Power Level at Octave Band Centre Frequency for Plant 11-16
                     Sound Emission Sources.......................................................................................22 
Table 7              Sound Power Level at Octave Band Centre Frequency for Application
                     Case Outdoor Area Emission Sources ..................................................................23 
Table 8              Sound Power Level at Octave Band Centre Frequency for Application
                     Case Building Sound Emission Sources ...............................................................23 
Table 9              Baseline Case Building Wall and Roof Height Summary ......................................32 
Table 10             Application Case Building Wall and Roof Height Summary ..................................33 
Table 11             Noise Source Ranking at Critical Receptor – Hunter/Trapper Cabin A.................35 
Table 12             Permissible Sound Levels at Hunter/Trapper Cabins A, B and Christina
                     Lake Lodge ............................................................................................................38 
Table 13             Permissible Sound Levels at Conklin ....................................................................39 




                                                              Volume 3
EnCana FCCL Ltd.                                       - ii -                            Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                         Appendix 3-VI
Phases 1E, 1F and 1G                                                                               October 2009

                                            LIST OF FIGURES

Figure 1      Addition of Multiple Sources of Noise ......................................................................4 
Figure 2      Effect of Distance in Attenuating Noise Levels........................................................5 
Figure 3      Effect of Distance in Attenuating Roadway Noise Levels........................................7 
Figure 4      Effects of Obstacles on the Attenuation of Sound ...................................................8 




                                                   Volume 3
EnCana FCCL Ltd.                              -1-                      Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                       Appendix 3-VI
Phases 1E, 1F and 1G                                                             October 2009


1           INTRODUCTION

               EnCana FCCL Ltd. (EnCana) as operator for FCCL Partnership has been
               developing and operates a commercial scheme for the recovery of bitumen from
               the McMurray Formation at Christina Lake located in Section 16, Township 76,
               Range 6, West of the Fourth Meridian (W4M). This scheme, including the use of
               in-situ Steam Assisted Gravity Drainage (SAGD) extraction well pairs and an on-
               site plant, operates under approvals issued by the Energy Resources Conservation
               Board (ERCB), No. 8591 and Alberta Environment (AENV), No. 48522-00-09.
               The Christina Lake Thermal Project (CLTP) is located about 20 km southeast of
               the community of Conklin, Alberta.

               The original application for the CLTP was submitted to AENV and the ERCB
               formally known as Alberta Energy and Utilities Board in March 1998. In 2000,
               the CLTP was approved by the ERCB and AENV for production of 70,000 bbl/d
               (11,200 m³/d) of bitumen over three phases of development (Phases 1, 2 and 3)
               each with a separate plant site.

               Through a series of approval amendments the CLTP has been approved by the
               ERCB and AENV for a production of 98,800 bbl/d (15,709 m³/d) of bitumen
               through the construction, operation and reclamation of Phases 1A, 1B, 1C and
               1D. The amendments have involved expanding the original CLTP plant site
               instead of building three separate plant sites as originally proposed. Incremental
               production capacity originally envisioned from Phases 2 and 3 will still occur
               within the development area in a staged approached, increasing production at the
               Phases 1A and 1B site by 40,000 bbl/d (6,360 m³/d) per phase via addition of
               Phases 1C and 1D. Overall surface disturbance has been reduced by combining
               the originally proposed three-phase (Phases 1, 2 and 3) into one larger expanded
               plant at a central location (Phases 1A to 1D).

               The Christina Lake Thermal Expansion Project, Phases 1E, 1F and 1G (the
               Project) involves modifications and additions to the existing Christina Lake
               Phases 1A to 1D facilities to increase oil treating capacity to 218,800 bbl/d
               (34,789 m³/d). This amendment involves expanding the approved Christina Lake
               facilities at the Phase 1 site by building three additional 40,000 bbl/d
               (6,360 m³/d) phases, namely 1E, 1F and 1G. This will bring the cumulative
               production to 218,800 bbl/d (34,789 m³/d) and total of 23 Once Through Steam
               Generators (OTSGs) for Phases 1A to 1G (Expanded CLTP).

               In addition to the central plant modifications up to 19 well pads and 141 well
               pairs will be added. As well, up to 12 remote water disposal wells (located in
               Township 77, Range 3, W4M) and up to 11 saline water source wells on four



                                            Volume 3
EnCana FCCL Ltd.                                          -2-              Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                           Appendix 3-VI
Phases 1E, 1F and 1G                                                                 October 2009

                   well pads (located in Township 75, Range 6, W4M) will be added. Other
                   supporting infrastructure modifications which are not part of the ERCB scheme
                   such as diluent pipelines and Enbridge storage terminal tank, road upgrades,
                   utilities, offices and camps will be applied for separately as appropriate.


1.1            NOISE TERMINOLOGY

                   An introduction to the concepts and theories used in the assessment of outdoor
                   acoustics is provided in Appendix 3-VI. The key concepts and terms for noise
                   evaluation are included in Section 7.


1.2            NOISE LEVELS

                   Noise levels from common sources are provided in Table 1 to provide a reference
                   when comparing the noise levels predicted for the Project. The noise levels listed
                   in the table represent average values and may vary from one situation to the next.

Table 1           Summary of Noise Levels Associated With Common Activities
                                                                           Noise Level
                               Activity
                                                                             [dBA]
 lawnmower                                                                 88 to 93 at 5 ft
 portable hair dryer                                                       77 to 86 at 1 ft
 vacuum cleaner                                                            78 to 85 at 5 ft
 food blender                                                              76 to 81 at 3 ft
 microwave oven                                                            56 to 58 at 3 ft
 schools, libraries, churches, hospitals, nursing homes                    60 to 65
 dehumidifier                                                              58 to 60 at 5 ft
 rustling leaves in wind                                                   55 to 58
 summer nighttime insects                                                  50 to 54 in open field
 whispered speech                                                          40
 average rural sound level at night                                        35
Source: (Cowan 1994).



1.3            NOISE PREDICTION METHODS

                   Two basic acoustic principals are the key to the evaluation of noise levels
                   expected from the Project. The first deals with the addition of multiple noise
                   sources. The second concept deals with the attenuation of noise levels in the
                   environment.




                                                      Volume 3
EnCana FCCL Ltd.                              -3-                      Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                       Appendix 3-VI
Phases 1E, 1F and 1G                                                             October 2009

1.3.1       Addition of Noise Levels

               Since noise levels are measured on a logarithmic scale, the combined effect of
               multiple sources is calculated accordingly.

               The following formula is used to combine multiple sources:


                                 ⎛ dBA1     dBA2    dBA3        dBAn
                                                                            ⎞
                   dBA = 10 × log⎜10 10 + 10 10 + 10 10 + K + 10 10         ⎟
                                 ⎜                                          ⎟
                                 ⎝                                          ⎠

               The effects of additional noise sources on ambient noise levels are illustrated in
               Figure 1. If the sound emitted from a single facility results in noise levels of
               40 dBA, then the emissions from two facilities would result in noise levels of
               43 dBA. Therefore, a doubling of the sound emissions would result in a 3 dBA
               increase in the noise levels. When the emissions from a third facility are added,
               the noise level increases to 44.8 dBA.


1.3.2       Attenuation of Noise in the Environment

               There are several factors that can mitigate noise emissions in the environment.
               These mitigating factors are referred to as noise attenuation. The most important
               factor for noise attenuation is the distance between the source and the receptor.

               As distance increases, noise levels decrease. For facilities, the noise levels at
               increased distances can be calculated using the following formula (EUB 2007):

                               L(R2) = L(R1) – 20 Log10(R2/R1)

               The effect of distance on noise levels is illustrated in Figure 2. The figure
               illustrates that a doubling of the distance from a facility results in a 6 dBA
               reduction in the noise levels. Therefore, increasing the distance from 500 to
               1,000 m will drop the noise level from 40 to 34 dBA. Increasing the distance
               another 500 m from 1,000 to 1,500 m would decrease the noise level from
               34 to 30.5 dBA.




                                            Volume 3
                      CHRISTINA LAKE
          THERMAL EXPANSION PROJECT
                 PHASES 1E, 1F AND 1G

ADDITION OF MULTIPLE SOURCES
          OF NOISE



                         FIGURE: 1
          40 dBA




500 m




                             34 dBA




        1,000 m




                                               30.5 dBA




                   1,500 m

                                                              CHRISTINA LAKE
                                                  THERMAL EXPANSION PROJECT
                                                         PHASES 1E, 1F AND 1G

                                      EFFECT OF DISTANCE IN ATTENUATING
                                                 NOISE LEVELS



                                                                 FIGURE: 2
EnCana FCCL Ltd.                              -6-                        Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                         Appendix 3-VI
Phases 1E, 1F and 1G                                                               October 2009

               Noise from a roadway acts in a slightly different manner. The noise from a
               roadway is emitted along the entire length. As distance increases, the noise
               levels decrease at a slower rate than from a facility.

               The amount that the noise decreases can be calculated using the following
               formula (OE 1989, 1999):

                           L(R2) = L(R1) – 10 (1+α) Log10(R2/R1)


                           dBALp(R2) = dBALp(R1) – 10 × (1 + α) × log (R1/R2)

               In the above formula, the alpha term (α) is added to account for the nature of the
               ground surface between the road and the receptor. For paved or concrete
               surfaces, α is equal to zero. Therefore, a doubling of the distance from a paved
               or concrete roadway would result in a 3 dBA reduction in the noise levels
               (Figure 3). In most rural situations, the ground between the road and the receptor
               is softer, and covered with different surfaces such as gravel, fill or vegetation. In
               these situations, α would be larger than zero (typically in the range of 0.6). With
               the same doubling of distance, the noise level drops from 40 to 35.2 dBA when
               the ground between the roadway and receptor is soft.

               Several other environmental factors will result in attenuation of emitted sounds.
               These include the absorption of sound by air, the effect of barriers or hills on
               noise levels, and the effect of trees and ground on the emitted noise.

               As sound passes through the atmosphere it collides with air molecules,
               converting some of the energy into heat. This transfer of energy results in a
               decrease in the sound energy. The amount of energy that the atmosphere absorbs
               varies with weather conditions and the frequency of sound. Low frequency
               sounds (those not readily detected by the human ear) are relatively unaffected by
               the atmosphere. The mid-range frequency sounds, which are most readily
               detected by the human ear, can lose significant energy to the atmosphere.

               Barriers and hills can also attenuate sound in the environment. As the sound
               waves “bend” around obstructions, they lose a great deal of energy. This
               phenomenon explains the use of barriers along major highways in urban areas.
               This also explains why people do not usually hear sounds from sources that are
               behind hills. The amount of attenuation afforded by an obstruction is a function
               of the amount the sound waves bend. Therefore, the attenuation is greatest close
               to the source, and is less effective at greater distances. Figure 4 illustrates how
               hills can attenuate industrial sounds.



                                            Volume 3
               40 dBA




50 m




                                      37 dBA



       Pavement or concrete

              100 m




                                      35.2 dBA



        Soft ground or soil

              100 m



                                                        CHRISTINA LAKE
                                            THERMAL EXPANSION PROJECT
                                                   PHASES 1E, 1F AND 1G

                              EFFECT OF DISTANCE IN ATTENUATING
                                   ROADWAY NOISE LEVELS



                                                           FIGURE: 3
            55 dBA




500 m




            35 dBA




500 m


                             CHRISTINA LAKE
                 THERMAL EXPANSION PROJECT
                        PHASES 1E, 1F AND 1G

        EFFECTS OF OBSTACLES ON
        THE ATTENUATION OF SOUND



                                FIGURE: 4
EnCana FCCL Ltd.                              -9-                        Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                         Appendix 3-VI
Phases 1E, 1F and 1G                                                               October 2009

               The next type of attenuation is the effect of trees on noise levels. Since trees are
               not solid they do not act the same as a barrier. However, a stand of trees can
               afford a good deal of attenuation if they are sufficiently deep and tall. The
               degree of attenuation is a function of the frequency of the noise, the trees species,
               the extent of trees and whether there are any edge effects. In evaluating noise for
               the Project, trees were not considered due to the additional uncertainty added to
               the modelling. This is expected to result in a conservative assessment since there
               are substantial stands of trees between the site and some receptors.

               The final method of environmental attenuation deals with the interaction of
               sounds with the ground. The degree of attenuation varies with the weather
               conditions and the ground absorption. This attenuation has been incorporated in
               the model used to calculate the attenuation for all sources of noise for the Project.

               In addition to environmental attenuation from distance, ground obstructions, trees
               and other natural features, anthropogenic features can also reduce sound levels.
               Project buildings, weather enclosures, exhaust mufflers and other similar
               components reduce the amount of noise effects from facilities. Noise-reducing
               components can be designed to increase reductions in noise emissions beyond
               what would otherwise result (e.g., addition of extra insulation to structures).




                                            Volume 3
EnCana FCCL Ltd.                              - 10 -                     Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                         Appendix 3-VI
Phases 1E, 1F and 1G                                                               October 2009


2           NOISE MODELLING

2.1         MODEL SELECTION

               In selecting a prediction model to evaluate noise levels due to sound emitted
               from the Project, the following key conditions were considered:

                    •   can the model evaluate the various source types present at the site;
                    •   can the model predict the necessary environmental noise indicators;
                    •   does the model have a basis that is scientifically sound, and is in
                        keeping with the current standards regarding environmental sound; and
                    •   is the model suitable to predict noise in accordance with ERCB
                        Directive 038: Noise Control (EUB 2007).

               The Computer Aided Noise Attenuation (CadnaA) prediction model (developed
               by DataKustik 2006) was identified as appropriate for assessing the noise effects
               associated with the Project. The algorithms used by the model are consistent
               with ERCB directives. The model was used to determine the hourly equivalent
               continuous sound level (Leq) generated by the Application Case activities at the
               selected sensitive receptors. It was also used to indicate where noise from the
               Project may occur in the areas surrounding the site, for each key operating
               scenario.

               The model has the capability to simulate emission sources such as roads,
               railways, airports and industrial facilities, which are represented as a series of
               point, line and area sources. Each source type can be characterized by entering
               noise emissions in terms of total noise or as the frequency components of the
               emission. Other parameters such as building dimensions and equipment
               enclosure noise attenuation ratings also define the nature of noise emissions. The
               CadnaA model also accounts for noise attenuation related to meteorological
               (prevailing wind) conditions, ground cover and physical barriers, either natural
               (terrain based) or anthropogenic.


2.2         NOISE MODELLING LIMITATIONS

               The modelling of outdoor noise attenuation is conducted using standard
               algorithms and assumptions that tend to simplify the acoustic environment.
               Noise, whether natural or anthropogenic, is normally variable over time. The
               algorithms and the Leq indicator account for that variability, but do not predict it.
               The variation of noise sources over time can be addressed in the CadnaA model



                                            Volume 3
EnCana FCCL Ltd.                             - 11 -                     Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                        Appendix 3-VI
Phases 1E, 1F and 1G                                                              October 2009

               in many ways, depending on the noise source being assessed and the level of
               detail required.

               The quality and relevance of predictions from the noise model is dependant on
               the data inputs. For the assessment, noise sources were established with field
               measurements of similar equipment or vendor sound emission data where
               available to ensure the accuracy of sources. Where spectral data was not
               available, typical spectrum data from acoustical literature was used to provide
               representative data.

               The CadnaA model was designed to predict outdoor noise in accordance with
               International Organization for Standardization (ISO) 9613 (1 and 2):
               Attenuation of Sound During Propagation Outdoors (ISO 1996) as well as
               several international and European acoustic standards. The ISO 9613 method
               predicts noise attenuation to within ±3 dBA. Supplier literature and third-party
               publications do not verify this level of accuracy for the CadnaA model. To
               validate that the CadnaA model meets the ISO standard, an independent study
               was completed that verified the model calculates the ISO method correctly and
               that simulations of outdoor noise levels match field measurements of a known
               source to within ±3 dBA (Drew et al. 2005).


2.3         SCIENTIFIC UNCERTAINTY

               As indicated in Section 2.2, the modelling of outdoor noise attenuation is
               conducted using standard algorithms and assumptions that tend to simplify the
               acoustic environment. Normal variation of noise sources is addressed in the
               modelling depending on the noise source being assessed and the level of detail
               required.

               The quality and relevance of predictions from the noise model is dependant on
               the data inputs. Sound emissions and site data used for the assessment were
               established with a high level of professional care to provide simulations that were
               representative of the site, yet conservative. The conservatism helps address
               uncertainties in the data and predictions.

               The CadnaA model used for the assessment predicted noise levels in accordance
               with International Organization for Standardization 9613 (1 and 2): Attenuation
               of Sound During Propagation Outdoors (ISO 1996). The ISO 9613 method
               predicts noise attenuation to within ±3 dBA.




                                            Volume 3
EnCana FCCL Ltd.                                            - 12 -                            Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                              Appendix 3-VI
Phases 1E, 1F and 1G                                                                                    October 2009

2.4              MODEL CONFIGURATION

                      Table 2 lists the configuration of the calculation parameters used to complete
                      noise modelling for the Project.

Table 2               Noise Model Configuration Parameters
        Parameter                  Model Setting                                   Description/Notes
                                           (a)              all sources and attenuators are treated as required by the cited
 standards                  ISO 9613 only
                                                            standard
                                                            building enclosures with indoor noise sources were modelled as
                                                            structures with one horizontal area source (roof) and four
                            steam generator stack;          vertical area sources along the sides; hence, directivity of the
 source directivity         vertical/building sources       source emission and the barrier effect of the unit itself were
                            applied to larger structures    included
                                                            note the design process is not sufficiently advanced to warrant
                                                            application of directionality to smaller sources such as air inlets
 ground absorption                   0.4                    area is comprised of boreal forest
 temperature/humidity       10°C/70% Relative Humidity      average summer conditions for the area
                                                            the propagation conditions in the ISO standard are valid for wind
                            default ISO 9613 –
 wind conditions                                            speeds between 4 and 18 km/hr; all points are considered
                            moderate inversion condition
                                                            downwind
                            no terrain considered           terrain in the area is relatively flat as no obvious ridges or
 terrain
                            (conservative scenario)         natural barriers were identified in the field study
                                                            one order reflection is taken into account as mirror image
 reflections                           1                    sources from reflecting structures (e.g., pre-engineered metal
                                                            building)
(a)
      Source: (ISO 1996).



                      The ERCB Directive 038 lists meteorological parameter ranges to use for noise
                      modelling (EUB 2007). These include temperatures between 0 to 25°C, relative
                      humidity between 70 to 90% and wind speeds between 5.0 to 7.5 km/hr. Wind
                      directions and ground cover as noted by ERCB Directive 038 are consistent with
                      site conditions entered into the model.




                                                           Volume 3
EnCana FCCL Ltd.                             - 13 -                   Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                      Appendix 3-VI
Phases 1E, 1F and 1G                                                            October 2009


3           SOURCE-SPECIFIC MODEL DATA

               Tables 3 through 6 list the sound emission spectra for the existing and approved
               sources associated with the CLTP (Baseline Case). Tables 7 and 8 list the sound
               emission spectra for the Project (Application Case) noise sources.

               For all buildings, the total sound power levels (Lw) used in the model are
               provided. These values were used to calculate the noise emissions from building
               walls and roofs. Tables 9 and 10 summarize the building wall and roof heights
               used in the model.




                                            Volume 3
EnCana FCCL Ltd.                                                                    - 14 -                                               Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                                         Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                               October 2009

Table 3              Sound Power Level at Octave Band Centre Frequency for Baseline Case Outdoor Area Emission
                     Sources
                                                                                Sound Power Level at Octave Band Centre Frequency
                                                                                                                                                           Overall
           Tag Number                      Source Name                                             [Hz], [dBA]
                                                                    31.5      63     125     250       500     1,000   2,000   4,000        8,000    [dB]       [dBA]
                –                  transformer                      32        51        63         65     71      68       64       59        50      83         74
                –                  vapour recovery unit ejector     41        57        70         80     89      95       99      102       103     107        107
                –                  well pads                        57        64        68         67     66      58       50       39        31      97         73
                                   glycol air cooler inlet          69        80        90        90      93      94       91       89        75     112         99
 E524A
                                   glycol air cooler outlet         68        79        88         89     92      93       90       88        73     111         98
                                   inlet vapour air cooler inlet    75        88        97        101    101     100       95       94        88     120        107
 AC-4060A/B
                                   inlet vapour air cooler outlet   65        78        87         91     90      90       85       84        78     109         96
                                   glycol air cooler inlet          71        84        92         96     96      95       90       89        83     115        102
 AC-7150 A/B/C/D/E/F/G/H
                                   glycol air cooler outlet         65        78        87         91     90      90       85       84        78     109         96
– = Not available.



Table 4              Sound Power Level at Octave Band Centre Frequency for Baseline Case Building Sound Emission
                     Sources
                                                                                    Sound Power Level at Octave Band Centre Frequency
    Tag                                                                                                                                                    Overall
                                  Source Name                                                          [Hz], [dBA]
   Number
                                                                      31.5         63     125     250      500     1,000   2,000   4,000     8,000   [dB]       [dBA]
       –         air compressor building (CK-531A)                     51          72      81      92       98       99      95      92        85    107         103
       –         air compressor building (CK-531B)                     51          72      81      92       98       99      95      92        85    107         103
                 diluent pump building roof (P-303A/B)                 46          60      71      80       88       92      92      87        78     98          97
       –         diluent pump building wall (P-303A/B)                 51          64      76      85       93       97      96      92        83    103         101
                 diluent pump building ventilation fan                 27          42      55      69       73       75      73      67        63     83          79
                 glycol boiler building roof                           56          82     100      96     100       100     100      91        81    117         107
       –
                 glycol boiler building wall                           65          91     109    105      108      109      109    100         90    126         115
                 induced gas flotation pump building roof              56          69      82      91     102      104      102      92        78    109         107
                 induced gas flotation pump building wall              63          76      89      98     109      111      109      99        86    116         114
       –         induced gas flotation pump building ventilation
                                                                         35        50        63     77     81       83      81      75        71      91             87
                 fan
                 induced gas flotation pump building louvre              35        48        61     70     81       83      81      72        58      89          87
                 east pump building roof                                 60        73        84     98    102      103     100      93        82     112         107
       –         east pump building wall                                 67        79        91    105    109      109     107      99        89     118         114
                 east pump building ventilation fan                      27        42        55     69     73       75      73      67        63      83          79
       –         east pump building louvre                               36        49        60     75     78       79      77      69        59      88          84



                                                                               Volume 3
EnCana FCCL Ltd.                                                           - 15 -                                            Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                             Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                   October 2009

Table 4          Sound Power Level at Octave Band Centre Frequency for Baseline Case Building Sound Emission
                 Sources (continued)
                                                                           Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                       Overall
                                Source Name                                                   [Hz], [dBA]
  Number
                                                                   31.5   63     125     250      500     1,000   2,000   4,000   8,000   [dB]    [dBA]
               west pump building roof                              60    64      80      82       90       93      91      87      75    103       97
               west pump building west wall                         67    70      87      89       97     100       98      94      82    110      104
      –
               west pump building ventilation fan                   27    42      55      69       73       75      73      67      63     83       79
               west pump building louvre                            38    42      58      61       68       71      69      65      53     81       75
               sap compressor unit roof                             40    47      58      67       68       70      65      59      42     83       74
               sap compressor unit wall                             47    54      65      74       76       77      72      67      49     90       81
      –        sap compressor cooler unit roof                      68    80      89      89       93       93      90      88      74    111       98
               sap compressor cooler unit wall                      69    80      89      89       93       93      90      88      74    112       99
               sap compressor unit ventilation fan                  27    42      55      69       73       75      73      67      63     83       79
      –        worker’s camp                                        51    73      70      70       76       78      77      67      62    100       83
               once through steam generator building stack          74    78      82      88       82       80      79      74      54    114       91
               once through steam generator building roof           70    82      92    102      107       109     108    104       94    118      114
               once through steam generator building wall           74    86      95    106      110      113      111    107       98    121      117
   B-1725      once through steam generator building ventilation
                                                                   35     50         63    77     81       83      81      75      71      91          87
               fan
               once through steam generator building louvre        48     60        70    81      85       87      86      82      72      96          92
               once through steam generator building stack
                                                                   74     78         82    88     82       80      79      74      54     114          91
               (B-101)
               once through steam generator building stack
                                                                   70     73         70    79     77       76      76      72      56     110          84
               (B-102)
               once through steam generator/make-up water
                                                                   82     94        103   114    118      121     119     115     106     129      125
               treatment building roof
               once through steam generator/make-up water
                                                                   83     94        104   115    119      122     120     116     107     130      126
               treatment building wall
  BU-0101      once through steam generator/make-up water
                                                                   36     51         64    78     82       84      82      76      72      92          88
               treatment building air conditioning unit
               once through steam generator/make-up water
                                                                   31     46         59    73     77       79      77      71      67      87          83
               treatment building ventilation fan
               once through steam generator/make-up water
                                                                   48     60         70    81     85       87      86      82      72      96          92
               treatment building louvre
               make-up water treatment building (addition) roof    39     53        65    75      81       86      85      80      71      92          90
               make-up water treatment building (addition) wall    40     54        66    76      82       88      86      82      72      93          91
  BU-0101
  (addition)   make-up water treatment building (addition)
                                                                   31     46         59    73     77       79      77      71      67      87          83
               ventilation fan




                                                                          Volume 3
EnCana FCCL Ltd.                                                     - 16 -                                            Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                       Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                             October 2009

Table 4          Sound Power Level at Octave Band Centre Frequency for Baseline Case Building Sound Emission
                 Sources (continued)
                                                                     Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                 Overall
                               Source Name                                              [Hz], [dBA]
  Number
                                                             31.5   63     125     250      500     1,000   2,000   4,000   8,000   [dB]    [dBA]
               make-up water treatment building (addition)
  BU-0101                                                    48     60        70    81      85       87      86      82      72      96          92
               louvre
  (addition)
 (continued)   produced water treatment warm lime softener
                                                             57     70        82    91      99      103     103      98      89     109      108
               building roof
               produced water treatment warm lime softener
                                                             58     72        84    93     101      105     104      99      90     111      109
               building wall
               produced water treatment warm lime softener
                                                             35     50        63    77      81       83      81      75      71      91          87
  BU-0106      building ventilation fan
               produced water treatment warm lime softener
                                                             32     45        57    66      75       78      78      73      64      84          83
               building louvre
               recycle oil pump building roof                49     62        75    84      93       96      96      91      81     102      101
               recycle oil pump building wall                49     62        75    84      93       96      96      91      81     102      101
               recycle oil pump building ventilation fan     35     50        63    77      81       83      81      75      71      91       87
  BU-0107
               recycle oil pump building louvre              23     36        49    58      67       70      70      65      55      76       75
               production building roof                      68     75        95   107     106      115     106     100      93     120      117
               production building wall                      73     79        99   111     111      120     110     105      97     124      121
               production building ventilation fan           35     50        63    77      81       83      81      75      71      91       87
  BU-0301
               production building louvre                    41     48        68    80      79       88      79      73      66      93       90
               gravity separator building roof               54     62        77    88      89       88      86      81      72     101       94
               gravity separator building wall               59     67        82    93      94       93      91      86      77     106       99
               gravity separator building ventilation fan    27     42        55    69      73       75      73      67      63      83       79
  BU-0302
               gravity separator building louvre             30     38        53    64      65       65      63      57      48      77       71
               pump building roof                            43     56        68    77      85       89      88      84      75      95       93
               pump building wall                            49     62        74    83      91       95      94      90      81     101       99
  BU-0319      pump building ventilation fan                 27     42        55    69      73       75      73      67      63      83       79
               deoiling building roof                        63     79        86   101     105      105     105     101      92     115      111
               deoiling building wall                        64     81        88   102     106      107     107     103      94     116      113
               deoiling building ventilation fan             35     50        63    77      81       83      81      75      71      91       87
  BU-1001
               deoiling building louvre                      36     52        59    74      78       78      78      74      65      88       84
               deoiling building roof                        63     79        86   101     105      105     105     101      92     115      111
               deoiling building wall                        64     81        88   102     106      107     107     103      94     116      113
               deoiling building ventilation fan             34     49        62    76      80       82      80      74      70      90       86
  BU-1002
               deoiling building louvre                      36     53        60    74      78       79      79      75      66      88       85
               water/oil recycle pump building roof          51     64        77    86      95       98      98      93      83     104      103




                                                                    Volume 3
EnCana FCCL Ltd.                                                        - 17 -                                            Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                          Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                October 2009

Table 4       Sound Power Level at Octave Band Centre Frequency for Baseline Case Building Sound Emission
              Sources (continued)
                                                                        Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                    Overall
                             Source Name                                                   [Hz], [dBA]
  Number
                                                                31.5   63     125     250      500     1,000   2,000   4,000   8,000   [dB]    [dBA]
            water/oil recycle pump building wall                 54    68      80      89       98      101     101      96      86    107      106
  BU-1005   water/oil recycle pump building ventilation fan      29    44      57      71       75       77      75      69      65     85       81
            water/oil recycle pump building louvre               29    43      55      64       73       76      76      71      61     82       81
            deoiling area chemical lab building air
                                                                29     44        57    71      75       77      75      69      65      85          81
  BU-1007   conditioning unit
            deoiling area lab building ventilation fan          30     45        53    65      61       70      69      65      58      79       74
            regeneration waste pump building                    50     63        75    84      93       96      96      91      82     102      101
  BU-1009
            regeneration waste pump building ventilation fan    20     35        48    62      66       68      66      60      56      76       72
            regeneration waste pump building roof               51     65        77    86      95       98      98      93      83     104      103
            regeneration waste pump building wall               56     69        82    91     100      103     103      98      88     109      108
  BU-1010   regeneration waste pump building ventilation fan    24     39        52    66      70       72      70      64      60      80       76
            regeneration waste pump building louvre             29     42        55    64      72       76      75      70      61      82       80
            produced water treatment building roof              57     71        83    92     100      104     103      99      89     110      108
            produced water treatment building wall              57     70        83    92     100      104     103      98      89     110      108
            produced water treatment building ventilation fan   34     49        62    76      80       82      80      74      70      90       86
  BU-1501
            produced water treatment building louvre            29     42        54    63      72       75      75      70      61      81       80
            warm lime softener building roof                    46     59        72    81      89       93      92      87      78      99       97
            warm lime softener building wall                    48     61        74    83      91       95      95      90      80     101      100
            warm lime softener building ventilation fan         35     50        63    77      81       83      81      75      71      91       87
            warm lime softener building louvre                  20     33        46    55      64       67      67      62      52      73       72
  BU-1701
            steam generator stack (B-2100/B-2200/B-
                                                                74     78        82    88      82       80      79      74      54     114          91
            2300/B-2400)
            steam generator building roof                       73     81        89    90      91       93      91      85      73     114          98
            steam generator building wall                       73     81        89    90      91       93      90      85      73     114          98
            steam generator building ventilation fan            34     49        62    76      80       82      80      74      70      90          86
            steam generator building louvre                     43     56        56    69      75       76      75      67      54      87          81
  BU-2001   steam generator air inlet (E-2135/E-2235/E-
                                                                69     84        88    97     100      101      94      83      66     115      105
            2335/E-2435)
            boiler feed water charge pump/steam separator
                                                                71     84        95   103     108      106     101     104      87     118      112
            building roof
            boiler feed water charge pump/steam separator
                                                                70     82        93   101     107      104     100     103      85     117      111
            building wall
  BU-2003
            boiler feed water charge pump/steam separator
                                                                35     50        63    77      81       83      81      75      71      91          87
            building ventilation fan




                                                                       Volume 3
EnCana FCCL Ltd.                                                           - 18 -                                            Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                             Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                   October 2009

Table 4          Sound Power Level at Octave Band Centre Frequency for Baseline Case Building Sound Emission
                 Sources (continued)
                                                                           Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                       Overall
                                Source Name                                                   [Hz], [dBA]
  Number
                                                                   31.5   63     125     250      500     1,000   2,000   4,000   8,000   [dB]    [dBA]
               boiler feed water charge pump/steam separator
                                                                   44     57        67    76      81       78      74      77      60      91          85
  BU-2003      building louvre
 (continued)   boiler feed water charge pump/steam separator
                                                                   71     84        95   103     108      106     101     104      87     118      112
               building roof
               boiler feed water charge pump/steam separator
                                                                   72     85        96   104     110      107     102     105      88     120      114
               building wall
               boiler feed water charge pump/steam separator
                                                                   31     46        59    73      77       79      77      71      67      87          83
               building ventilation fan
  BU-2004
               boiler feed water charge pump/steam separator
                                                                   45     58        68    77      82       79      75      78      60      92          86
               building louvre
               boiler feed water booster pump/steam separator
                                                                   58     71        84    94     102      106     106     101      90     112      110
               building roof
               boiler feed water booster pump/steam separator
                                                                   61     74        87    96     105      108     108     103      93     114      113
               building wall
               boiler feed water booster pump/steam separator
                                                                   31     46        59    73      77       79      77      71      67      87          83
               building ventilation fan (194-PF-E)
  BU-2007
               boiler feed water booster pump/steam separator
                                                                   27     42        55    69      73       75      73      67      63      83          79
               building ventilation fan (154-PF-E)
               boiler feed water booster pump/steam separator
                                                                   38     51        64    73      81       85      84      79      70      91          89
               building louvre
               steam area chemical lab building air conditioning
                                                                   29     44        57    71      75       77      75      69      65      85          81
               unit
               steam area chemical lab building ventilation fan    30     45        53    65      61       70      69      65      58      79          74
  BU-2008
               steam generator stack (B-2500/B-2600/B-
                                                                   74     78        82    88      82       80      79      74      54     114          91
               2700/B-2800)
               steam generator building roof                       73     81        89    90      91       93      91      85      73     114          98
               steam generator building wall                       73     81        89    90      91       93      91      85      73     114          98
               steam generator building ventilation fan            34     49        62    76      80       82      80      74      70      90          86
  BU-2501      steam generator building louvre                     43     56        56    69      75       76      75      67      54      87          81
               steam generator air inlet (E-2535/E-2635/E-
                                                                   69     84        88    97     100      101      94      83      66     115      105
               2735/E-2835)
               free water knock out/treater building ventilation
  BU-4001                                                          34     49        62    76      80       82      80      74      70      90          86
               fan
               free water knock out/treater building ventilation
                                                                   31     46        59    73      77       79      77      71      67      87          83
  BU-4002      fan
               desand/decant pump building roof                    37     51        63    72      79       84      83      78      69      90          88




                                                                          Volume 3
EnCana FCCL Ltd.                                                          - 19 -                                            Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                            Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                  October 2009

Table 4       Sound Power Level at Octave Band Centre Frequency for Baseline Case Building Sound Emission
              Sources (continued)
                                                                          Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                      Overall
                              Source Name                                                    [Hz], [dBA]
  Number
                                                                  31.5   63     125     250      500     1,000   2,000   4,000   8,000   [dB]    [dBA]
            desand/decant pump building wall                       42    56      67      76       84       88      87      83      74     94       92
  BU-4004   desand/decant pump building ventilation fan            25    40      53      67       71       73      71      65      61     81       77
            desand/decant pump building louvre                     17    30      42      51       58       63      62      57      49     69       67
  BU-4005   inlet degasser building ventilation fan                31    46      59      73       77       79      77      71      67     87       83
            treater area chemical lab building air conditioning
                                                                  29     44        57    71      75       77      75      69      65      85          81
            unit
  BU-4006
            treater area chemical lab building ventilation fan    30     45        53    65      61       70      69      65      58      79       74
            crude flash drum building roof                        47     61        72    81      87       93      91      87      79      98       96
            crude flash drum building wall                        49     63        74    84      89       95      93      89      81     101       99
            crude flash drum building ventilation fan             31     46        59    73      77       79      77      71      67      87       83
  BU-5001
            crude flash drum building louvre                      25     38        51    60      68       72      71      66      57      78       76
            diluent pump building roof                            60     73        87    96     103      108     107     103      93     113      112
            diluent pump building wall                            62     76        89    98     106      110     109     105      95     116      114
            diluent pump building ventilation fan (154-PF-E)      27     42        55    69      73       75      73      67      63      83       79
  BU-6001   diluent pump building ventilation fan (194-PF-E)      29     44        57    71      75       77      75      69      65      85       81
            diluent pump building louvre                          39     52        64    73      82       85      85      80      71      91       90
            recycle oil pump building roof                        46     60        72    81      89       93      92      88      78      99       97
            recycle oil pump building wall                        49     62        74    83      91       95      95      90      81     101      100
            recycle oil pump building ventilation fan             27     42        55    69      73       75      73      67      63      83       79
  BU-6003
            recycle oil pump building louvre                      25     38        50    59      68       71      71      66      57      77       76
            lease automatic custody transfer building roof        57     67        81    97     107      111     108      98      87     115      114
            lease automatic custody transfer building wall        58     68        81    98     108      112     109      99      87     116      115
            lease automatic custody transfer building
                                                                  27     42        55    69      73       75      73      67      63      83          79
            ventilation fan (154-PF-E)
  BU-6005
            lease automatic custody transfer building
                                                                  29     44        57    71      75       77      75      69      65      85          81
            ventilation fan (194-PF-E)
            lease automatic custody transfer building louvre      35     47        44    68      78       81      77      66      52      86       84
            slop area lab building air conditioning unit          29     44        57    71      75       77      75      69      65      85       81
  BU-6006
            slop area lab building ventilation fan                30     45        53    65      61       70      69      65      58      79       74
            glycol heater building wall                           73     81        87    86      90       93      96      96      90     114      101
  H-7100    glycol heater building heater blower                  61     71        72    75      81       85      88      89      84     103       93
            glycol heater building roof                           62     76        88    97     106      109     109     104      95     115      114
            glycol heater building wall                           65     78        90   100     108      111     112     106      97     118      116
  BU-7101   glycol heater building ventilation fan (124-PF-E)     20     35        48    62      66       68      66      60      56      76       72
            glycol heater building ventilation fan (194-PF-E)     31     46        59    73      77       79      77      71      67      87       83




                                                                         Volume 3
EnCana FCCL Ltd.                                                              - 20 -                                            Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                                Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                      October 2009

Table 4              Sound Power Level at Octave Band Centre Frequency for Baseline Case Building Sound Emission
                     Sources (continued)
                                                                              Sound Power Level at Octave Band Centre Frequency
    Tag                                                                                                                                         Overall
                                  Source Name                                                    [Hz], [dBA]
   Number
                                                                      31.5   63     125     250      500     1,000   2,000   4,000   8,000   [dB]    [dBA]
  BU-7101
                glycol heater building louvre                         38     52        64    73      82       85      85      80      70      91          90
 (continued)
                glycol heater building wall                           73     81        87    86      90       93      96      96      90     114      101
   H-7200       glycol heater building heater blower                  61     71        72    75      81       85      88      89      84     103       93
                instrument air package building roof                  54     56        74    87      91       85      88      88      82     101       96
                instrument air package building wall                  57     59        77    90      94       88      91      91      85     104       99
                instrument air package building ventilation fan       29     44        57    71      75       77      75      69      65      85       81
   BU-7220
                steam blowdown/storm water pond pump
                                                                      44     57        70    79      87       91      90      85      76      97          95
                building roof
                steam blowdown/storm water pond pump
                                                                      46     59        72    81      89       93      92      87      78      99          97
                building wall
   BU-7701
                steam blowdown/storm water pond pump
                                                                      27     42        55    69      73       75      73      67      63      83          79
                building ventilation fan
   BU-7801      25kV switch gear building air conditioning unit       26     41        54    68      72       74      72      66      62      82          78
   BU-7802      motor control centre building air conditioning unit   27     42        55    69      73       75      73      67      63      83          79
   BU-7803      motor control centre building air conditioning unit   27     42        55    69      73       75      73      67      63      83          79
   BU-7804      motor control centre building air conditioning unit   27     42        55    69      73       75      73      67      63      83          79
   BU-7806      motor control centre building air conditioning unit   27     42        55    69      73       75      73      67      63      83          79
   BU-7807      motor control centre building air conditioning unit   26     41        54    68      72       74      72      66      62      82          78
   BU-7809      motor control centre building air conditioning unit   26     41        54    68      72       74      72      66      62      82          78
   BU-7814      electrical building air conditioning unit             26     41        54    68      72       74      72      66      62      82          78
   BU-7815      electrical building air conditioning unit             26     41        54    68      72       74      72      66      62      82          78
   BU-7817      electrical building air conditioning unit             26     41        54    68      72       74      72      66      62      82          78
   BU-7818      electrical building air conditioning unit             26     41        54    68      72       74      72      66      62      82          78
   BU-7823      electrical building air conditioning unit             26     41        54    68      72       74      72      66      62      82          78
   BU-7824      electrical building air conditioning unit             26     41        54    68      72       74      72      66      62      82          78
– = Not available.




                                                                             Volume 3
EnCana FCCL Ltd.                                                           - 21 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                            Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                  October 2009

Table 5              Sound Power Level at Octave Band Centre Frequency for Sulphur Recovery Facility Sound Emission
                     Sources
                                                                            Sound Power Level at Octave Band Centre Frequency
                                                                                                                                            Overall
      Tag Number                         Source Name                                           [Hz], [dBA]
                                                                   31.5     63       125   250    500     1,000   2,000   4,000   8,000   [dB]   [dBA]
                          compressor after cooler inlet            66       79       87    91      91       90      85     84       78    110     97
       AC-8825A/B
                          compressor after cooler outlet           62       75       83    87      87       86      81     80       74    106     93
                          lean amine cooler inlet                  67       80       88    92      92      91       86     85       79    111     98
         AC-8874
                          lean amine cooler outlet                 62       75       84    88      88       87      82     81       75    107     94
                          amine regenerator o/h condenser inlet    68       82       90    93      92       91      86     85       79    113     98
         AC-8862
                          amine regenerator o/h condenser outlet   63       76       85    89      88       88      83     82       76    107     94
                          age regenerator o/h condenser intlet     69       82       90    93      92       91      86     85       79    113     98
         AC-8902
                          age regenerator o/h condenser outlet     63       76       85    89      88       88      83     82       76    107     94
                          lean age cooler inlet                    67       80       88    92      92       91      86     85       79    111     98
         AC-8888
                          lean age cooler outlet                   63       76       85    89      88       88      83     82       76    107     94
             –            sulphur train A and B                    73       86       97    99      99       98      94     92       87    118    105
                          process glycol cooler inlet              57       71       78    82      81       80      75     73       67    101     87
       AG8975A/B
                          process glycol cooler outlet             52       65       74    78      78       77      73     72       66     97     84
        K8912A/B          combustion air blower/motor              59       75       85    89      92       91      89     86       76    106     97
                          age and amine building roof              61       74       87    96     104     108     108     103       94    114    112
                          age and amine building wall              57       71       83    92     101     104     104      99       90    110    108
             –            age and amine building ventilation fan   35       50       63    77      81      83       81     75       71     91     87
                          age and amine building louvre            32       45       57    66      75      78       78     73       64     84     83
                          utility building roof                    48       61       74    83      92      95       95     90       80    101    100
                          utility building wall                    46       59       72    81      90      93       93     88       78     99     98
             –            utility building ventilation fan         35       50       63    77      81      83       81     75       71     91     87
                          utility building louvre                  24       37       50    59      68      71       71     66       56     77     76
                          compressor package A and B roof          61       75       86    92      97     102     106     104       98    111    109
        K8815A/B
                          compressor package A and B wall          63       77       87    93      99     103     107     105       99    113    111
– = Not available.




                                                                          Volume 3
EnCana FCCL Ltd.                                                          - 22 -                                               Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                               Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                     October 2009

Table 6        Sound Power Level at Octave Band Centre Frequency for Plant 11-16 Sound Emission Sources
                                                                       Sound Power Level at Octave Band Centre Frequency
  Tag                                                                                                                                           Overall
                          Source Name                                                     [Hz], [dBA]
 Number
                                                           31.5   63        125     250       500     1,000    2,000   4,000      8,000   [dB]       [dBA]
           aerial glycol cooler inlet                      61     77        87       92       94        94       92      89         78    109         100
 AC735
           aerial glycol cooler outlet                     60     76        86       91       93        92       91      87         77    108          99
           1 stage reciprocating compressor roof           45     57        71       79       86        90       93      89         80     97          96
           1 stage reciprocating compressor building
                                                           43     54        68       77       83       87      90       86         77      95             94
           wall
 K740      1 stage reciprocating compressor building
                                                           35     50        63       77       81       83      81       75         71      91             87
           ventilation fan
           1 stage reciprocating compressor building
                                                           26     37        51       59       66       70      73       69         60      78             77
           louvre
           regenerative desiccant dryer building roof      49     62        75       80       83       86      82       74         64      96             90
           regenerative desiccant dryer building wall      49     62        74       80       83       85      82       73         63      96             89
 D755      regenerative desiccant dryer building
                                                           35     50        63       77       81       83      81       75         71      91             87
           ventilation fan
           regenerative desiccant dryer building louvre    34     47        59       64       68       70      66       58         48      81          74
           screw compressor                                54     67        78       85       93       97      99       96         90     105         103
           screw compressor ventilation fan                27     42        55       69       73       75      73       67         63      83          79
 K780A     screw compressor louvre                         34     47        59       64       68       70      66       58         48      81          74
           booster compressor utility cooler inlet         57     73        83       88       90       90      88       85         74     105          96
           booster compressor utility cooler outlet        57     73        84       88       90       90      88       85         75     105          96
           reciprocating compressor                        50     61        75       82       90       94      96       93         83     101         100
           reciprocating compressor ventilation fan        27     42        55       69       73       75      73       67         63      83          79
           reciprocating compressor louvre                 34     47        59       64       68       70      66       58         48      81          74
 K790A     reciprocating compressor utility cooler 1 and
                                                           57     73        83       88       90       90      88       85         74     105             96
           2 inlet
           reciprocating compressor utility cooler 1 and
                                                           55     71        81       86       88       88      86       83         72     103             94
           2 outlet
           4 stage centrifugal compressor and motors
                                                           51     65        76       85       92       96      98       93         86     103         102
           building roof
           4 stage centrifugal compressor and motors
                                                           49     63        74       83       90       94      96       91         84     101         100
           building wall
 K790B
           4 stage centrifugal compressor and motors
                                                           27     42        55       69       73       75      73       67         63      83             79
           building ventilation fan
           4 stage centrifugal compressor and motors
                                                           33     47        58       66       74       78      79       75         68      85             83
           building louvre
 TFXXX     4,160 V utility transformer                     32     51        63       65       71       68      64       59         50      83             74
 TF701     480 V utility transformer                       32     51        63       65       71       68      64       59         50      83             74
 TF702     4,160 V utility transformer                     32     51        63       65       71       68      64       59         50      83             74




                                                                        Volume 3
EnCana FCCL Ltd.                                                                  - 23 -                                              Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                                      Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                            October 2009

Table 7              Sound Power Level at Octave Band Centre Frequency for Application Case Outdoor Area Emission
                     Sources
                                                                                 Sound Power Level at Octave Band Centre Frequency
                                                                                                                                                        Overall
          Tag Number                       Source Name                                              [Hz], [dBA]
                                                                     31.5    63        125     250     500     1,000   2,000   4,000      8,000   [dB]       [dBA]
                –                  transformer                        32     51        63      65       71      68      64       59        50      83          74
                                   inlet vapour air cooler inlet      68     82        90      94       94      93      88       87        81     113         100
 AC-4060C
                                   inlet vapour air cooler outlet     65     78        87      91       90      90      85       84        78     110          97
                                   glycol air cooler inlet            71     84        92      96       96      95      90       89        83     115         102
 AC-7150 J/K/L/M
                                   glycol air cooler outlet           65     78        87      91       90      90      85       84        78     109             96
                                   glycol air cooler inlet            74     87        95      99       99      98      93       92        86     118         105
 AC-7350 A/B/C/D/E/F/G/H
                                   glycol air cooler outlet           65     78        87      91       90      90      85       84        78     109          96
– = Not available.



Table 8              Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
                     Sources
                                                                             Sound Power Level at Octave Band Centre Frequency
    Tag                                                                                                                                                 Overall
                                Source Name                                                     [Hz], [dBA]
   Number
                                                                    31.5    63        125     250     500     1,000    2,000   4,000     8,000    [dB]       [dBA]
                make-up water treatment building (addition)
                                                                    54      67        80      89       98      101     101       96        86     107         106
                roof
 BU-0101        make-up water treatment building (addition)
 (addition)                                                         59      72        85      94      102      106     105      100        91     112         110
                wall
                make-up water treatment building (addition)
                                                                    31      46        59      73       77       79      77       71        67      87             83
                ventilation fan
                produced water treatment building roof              57      71        83      92      100      104     103       99        89     110         108
                produced water treatment building wall              57      70        83      92      100      104     103       98        89     110         108
                produced water treatment building ventilation
 BU-0861                                                            34      49        62      76       80       82      80       74        70      90             86
                fan
                produced water treatment building louvre            29      42        54      63       72       75      75       70        61      81             80
                water/recycle oil pump building roof                51      64        77      86       95       98      98       93        83     104         103




                                                                             Volume 3
EnCana FCCL Ltd.                                                          - 24 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                           Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                 October 2009


Table 8        Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
               Sources (continued)
                                                                      Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                       Overall
                             Source Name                                                 [Hz], [dBA]
  Number
                                                              31.5   63       125   250      500    1,000    2,000   4,000     8,000   [dB]       [dBA]
            water/recycle oil pump building wall              54     68       80     89      98      101      101         96    86     107         106
            water/recycle oil pump building ventilation fan   29     44       57     71      75       77       75         69    65      85             81
 BU-0862
            water/recycle oil pump building louvre            29     43       55     64      73       76       76         71    61      82             81
            deoiling building roof                            63     79       86    101     105      105      105     101       92     115         111
            deoiling building wall                            64     81       88    102     106      107      107     103       94     116         113
 BU-0863    deoiling building ventilation fan                 35     50       63     77      81       83       81         75    71     91              87
            deoiling building louvre                          36     52       59     74      78       78       78         74    65      88             84
            deoiling area chemical lab building ventilation
                                                              30     45       53     65      61       70       69         65    58      79             74
 BU-0864    fan
            warm lime softener building roof                  48     61       74     83      91       95       95         90    80     101         100
            warm lime softener building wall                  48     61       74     83      91       95       95         90    80     101         100
            warm lime softener building ventilation fan       35     50       63     77      81       83       81         75    71     91              87
 BU-0865
            warm lime softener building louvre                20     33       46     55      64       67       67         62    52     73              72
            make-up water treatment building roof             59     72       85     94     103      106      106     101       91     112         111
            make-up water treatment building wall             59     72       85     94     103      106      106     101       91     112         111
            make-up water treatment building ventilation
 BU-0867                                                      31     46       59     73      77       79       77         71    67      87             83
            fan
            deoiling building roof                            63     79       86    101     105      105      105     101       92     115         111
            deoiling building wall                            64     81       88    102     106      107      107     103       94     116         113
            deoiling building ventilation fan                 35     50       63     77      81       83       81         75    71     91              87
 BU-0868
            deoiling building louvre                          36     52       59     74      78       78       78         74    65      88             84
            warm lime softener building roof                  46     59       72     81      89       93       92         87    78      99             97
            warm lime softener building wall                  48     61       74     83      91       95       95         90    80     101         100
            warm lime softener building ventilation fan       35     50       63     77      81       83       81         75    71     91              87
 BU-0869
            warm lime softener building louvre                20     33       46     55      64       67       67         62    52     73              72
            produced water treatment building roof            57     71       83     92     100      104      103         99    89     110         108




                                                                      Volume 3
EnCana FCCL Ltd.                                                          - 25 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                           Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                 October 2009


Table 8        Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
               Sources (continued)
                                                                      Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                       Overall
                             Source Name                                                 [Hz], [dBA]
  Number
                                                              31.5   63       125   250      500    1,000    2,000   4,000     8,000   [dB]       [dBA]
            produced water treatment building wall            57     70       83     92     100      104      103         98    89     110         108
            produced water treatment building ventilation
                                                              34     49       62     76      80       82       80         74    70      90             86
 BU-0871    fan
            produced water treatment building louvre          29     42       54     63      72       75       75         70    61      81             80
            regeneration water pump building roof             51     65       77     86      95       98       98         93    83     104         103
            regeneration water pump building wall             56     69       82     91     100      103      103         98    88     109         108
            regeneration water pump building ventilation
                                                              20     35       48     62      66       68       66         60    56      76             72
 BU-0872    fan
            regeneration water pump building louvre           29     42       55     64      72       76       75         70    61      82             80
            deoiling building roof                            63     79       86    101     105      105      105     101       92     115         111
            deoiling building wall                            64     81       88    102     106      107      107     103       94     116         113
            deoiling building ventilation fan                 35     50       63     77      81       83       81         75    71     91              87
 BU-1003
            deoiling building louvre                          36     52       59     74      78       78       78         74    65      88             84
            water/oil recycle pump building roof              51     64       77     86      95       98       98         93    83     104         103
            water/oil recycle pump building wall              54     68       80     89      98      101      101         96    86     107         106
 BU-1006    water/oil recycle pump building ventilation fan   29     44       57     71      75       77       75         69    65      85             81
            water/oil recycle pump building louvre            29     43       55     64      73       76       76         71    61      82             81
            deoiling area lab building ventilation fan        30     45       53     65      61       70       69         65    58     79              74
 BU-1008
            warm lime softener building roof                  48     61       74     83      91       95       95         90    80     101         100
            warm lime softener building wall                  52     66       77     86      93       98       96         92    84     104         102
 BU-1801    warm lime softener building ventilation fan       35     50       63     77      81       83       81         75    71     91              87
            warm lime softener building louvre                20     33       46     55      64       67       67         62    52     73              72




                                                                      Volume 3
EnCana FCCL Ltd.                                                        - 26 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                         Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                               October 2009


Table 8        Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
               Sources (continued)
                                                                    Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                     Overall
                            Source Name                                                [Hz], [dBA]
  Number
                                                            31.5   63       125   250      500    1,000    2,000   4,000     8,000   [dB]       [dBA]
            produced water treatment building roof          57     71       83     92     100      104      103         99    89     110         108
            produced water treatment building wall          57     70       83     92     100      104      103         98    89     110         108
            produced water treatment building ventilation
 BU-1901                                                    34     49       62     76      80       82       80         74    70      90             86
            fan
            produced water treatment building louvre        29     42       54     63      72       75       75         70    61     81              80
            boiler feed water charge pump/steam
                                                            71     84       95    103     108      106      101     104       87     118         112
            separator building roof
            boiler feed water charge pump/steam
                                                            73     86       97    105     110      108      103     106       89     120         114
            separator building wall
            boiler feed water charge pump/steam
                                                            35     50       63     77      81       83       81         75    71      91             87
            separator building ventilation fan
 BU-2005
            boiler feed water charge pump/steam
                                                            44     57       67     76      81       78       74         77    60      91             85
            separator building louvre
            boiler feed water booster pump/steam
                                                            62     75       88     98     105      110      109     104       94     115         114
            separator building roof
            boiler feed water booster pump/steam
                                                            65     78       91    100     108      112      111     106       97     118         116
            separator building wall
            boiler feed water booster pump/steam
                                                            29     44       57     71      75       77       75         69    65      85             81
            separator building ventilation fan (194-PF-E)
            boiler feed water booster pump/steam
 BU-2007                                                    31     46       59     73      77       79       77         71    67      87             83
            separator building ventilation fan (194-PF-E)
            boiler feed water booster pump/steam
                                                            27     42       55     69      73       75       73         67    63      83             79
            separator building ventilation fan (154-PF-E)
            boiler feed water booster pump/steam
                                                            38     51       64     73      81       85       84         79    70      91             89
            separator building louvre
            steam area chemical lab building ventilation
                                                            30     45       53     65      61       70       69         65    58      79             74
            fan
 BU-2009
            boiler feed water charge pump/steam
                                                            71     84       95    103     108      106      101     104       87     118         112
            separator building roof




                                                                    Volume 3
EnCana FCCL Ltd.                                                          - 27 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                           Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                 October 2009


Table 8        Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
               Sources (continued)
                                                                      Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                       Overall
                             Source Name                                                 [Hz], [dBA]
  Number
                                                              31.5   63       125   250      500    1,000    2,000   4,000     8,000   [dB]       [dBA]
            boiler feed water charge pump/steam
                                                              73     86       97    105     110      108      103     106       89     120         114
            separator building wall
            boiler feed water charge pump/steam
                                                              35     50       63     77      81       83       81         75    71      91             87
            separator building ventilation fan
 BU-3003
            boiler feed water charge pump/steam
                                                              44     57       67     76      81       78       74         77    60      91             85
            separator building louvre
            boiler feed water charge pump/steam
                                                              71     84       95    103     108      106      101     104       87     118         112
            separator building roof
            boiler feed water charge pump/steam
                                                              73     86       97    105     110      108      103     106       89     120         114
            separator building wall
            boiler feed water charge pump/steam
                                                              35     50       63     77      81       83       81         75    71      91             87
            separator building ventilation fan
 BU-3004
            boiler feed water charge pump/steam
                                                              44     57       67     76      81       78       74         77    60      91             85
            separator building louvre
            boiler feed water booster pump/steam
                                                              59     73       85     94     103      106      106     101       91     112         111
            separator building roof
            boiler feed water booster pump/steam
                                                              62     75       88     97     105      109      109     104       94     115         114
            separator building wall
            boiler feed water booster pump/steam
 BU-3007                                                      31     46       59     73      77       79       77         71    67      87             83
            separator building ventilation fan
            boiler feed water booster pump/steam
                                                              36     50       62     71      80       83       83         78    68      89             88
            separator building louvre
            steam area chemical lab building ventilation
 BU-3008                                                      30     45       53     65      61       70       69         65    58      79             74
            fan
            chelant injection package building ventilation
 BU-3098                                                      24     39       52     66      70       72       70         64    60      80             76
            fan
            sulphite injection package building ventilation
                                                              24     39       52     66      70       72       70         64    60      80             76
            fan
 BU-3099    steam generator stack (B-3100/B-3200/B-
                                                              74     78       82     88      82       80       79         74    54     114             91
            3300/B-3400)
            steam generator building roof                     73     81       89     90      91       93       91         85    73     114             98




                                                                      Volume 3
EnCana FCCL Ltd.                                                            - 28 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                             Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                   October 2009


Table 8        Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
               Sources (continued)
                                                                        Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                         Overall
                             Source Name                                                   [Hz], [dBA]
  Number
                                                                31.5   63       125   250      500    1,000    2,000   4,000     8,000   [dB]       [dBA]
            steam generator building wall                       73     81       89     90      91       93       90         85    73     114             98
            steam generator building ventilation fan            34     49       62     76      80       82       80         74    70     90              86
            steam generator building louvre                     43     56       56     69      75       76       75         67    54     87              81
 BU-3101    steam generator air inlet (E-3135/E-3235/E-
                                                                69     84       88     97     100      101       94         83    66     115         105
            3335/E-3435)
            steam generator stack (B-3160/B-3260/B-
                                                                74     78       82     88      82       80       79         74    54     114             91
            3360/B-3460)
            steam generator building roof                       73     81       89     90      91       93       91         85    73     114             98
            steam generator building wall                       73     81       89     90      91       93       90         85    73     114             98
            steam generator building ventilation fan            34     49       62     76      80       82       80         74    70     90              86
            steam generator building louvre                     43     56       56     69      75       76       75         67    54     87              81
 BU-3102    steam generator air inlet (E-3185/E-3285/E-
                                                                69     84       88     97     100      101       94         83    66     115         105
            3385/E-3485)
            steam generator stack (B-3500/B-3550/B-
                                                                74     78       82     88      82       80       79         74    54     114             91
            3600/B-3650)
            steam generator building roof                       73     81       89     90      91       93       91         85    73     114             98
            steam generator building wall                       73     81       89     90      91       93       90         85    73     114             98
            steam generator building ventilation fan            34     49       62     76      80       82       80         74    70     90              86
 BU-3103    steam generator building louvre                     43     56       56     69      75       76       75         67    54     87              81
            steam generator air inlet (E-3525/E-3575/E-
                                                                69     84       88     97     100      101       94         83    66     115         105
            3625/E-3675)
            free water knock out/treater building ventilation
 BU-4003                                                        34     49       62     76      80       82       80         74    70      90             86
            fan
            free water knock out/treater area chemical lab
                                                                30     45       53     65      61       70       69         65    58      79             74
 BU-4007    building ventilation fan
            desand/decant pump building roof                    37     51       63     72      79       84       83         78    69      90             88




                                                                        Volume 3
EnCana FCCL Ltd.                                                            - 29 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                             Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                   October 2009


Table 8        Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
               Sources (continued)
                                                                        Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                         Overall
                             Source Name                                                   [Hz], [dBA]
  Number
                                                                31.5   63       125   250      500    1,000    2,000   4,000     8,000   [dB]       [dBA]
            desand/decant pump building wall                    42     56       67     76      84       88       87         83    74      94             92
 BU-4008    desand/decant pump building ventilation fan         25     40       53     67      71       73       71         65    61      81             77
            desand/decant pump building louvre                  17     30       42     51      58       63       62         57    49      69             67
 BU-4009    inlet degasser building ventilation fan             31     46       59     73      77       79       77         71    67     87              83
            free water knock out/treater building ventilation
 BU-4010                                                        34     49       62     76      80       82       80         74    70      90             86
            fan
            free water knock out/treater building ventilation
 BU-4011                                                        34     49       62     76      80       82       80         74    70      90             86
            fan
            treater area chemical lab building ventilation
                                                                30     45       53     65      61       70       69         65    58      79             74
 BU-4012    fan
            crude flash drum building roof                      50     63       75     84      93       96       96         91    82     102         101
            crude flash drum building wall                      53     67       79     88      96      100       99         94    85     106         104
            crude flash drum building ventilation fan           31     46       59     73      77       79       77         71    67      87             83
 BU-5002
            crude flash drum building louvre                    25     38       51     60      68       72       71         66    57      78             76
            diluent pump building roof                          60     73       87     96     103      108      107     103       93     113         112
            diluent pump building wall                          62     76       89     98     106      110      109     105       95     116         114
            diluent pump building ventilation fan
                                                                27     42       55     69      73       75       73         67    63      83             79
            (154-PF-E)
 BU-6001    diluent pump building ventilation fan
                                                                29     44       57     71      75       77       75         69    65      85             81
            (194-PF-E)
            diluent pump building louvre                        39     52       64     73      82       85       85         80    71      91             90
            diluent pump building roof                          60     73       86     95     104      107      107     102       92     113         112
            diluent pump building wall                          63     76       88     97     106      109      109     104       95     115         114
            diluent pump building ventilation fan               29     44       57     71      75       77       75         69    65     85              81
 BU-6002
            diluent pump building louvre                        37     50       63     72      81       84       84         79    69      90             89
            lease automatic custody transfer building roof      59     72       68     93     103      106      101         91    77     111         109




                                                                        Volume 3
EnCana FCCL Ltd.                                                          - 30 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                           Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                 October 2009


Table 8        Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
               Sources (continued)
                                                                      Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                       Overall
                             Source Name                                                 [Hz], [dBA]
  Number
                                                              31.5   63       125   250      500    1,000    2,000   4,000     8,000   [dB]       [dBA]
            lease automatic custody transfer building wall    60     73       69     94     104      107      102         92    78     112         110
            lease automatic custody transfer building
 BU-6003                                                      27     42       55     69      73       75       73         67    63      83             79
            ventilation fan
            lease automatic custody transfer building
                                                              35     47       44     68      78       81       77         66    52      86             84
            louvre
            slop area chemical lab building ventilation fan   30     45       53     65      61       70       69         65    58     79              74
 BU-6004
            lease automatic custody transfer building roof    35     45       58     74      84       87       84         74    63      92             90
            lease automatic custody transfer building wall    35     45       58     74      84       87       84         74    63      92             90
            lease automatic custody transfer building
                                                              27     42       55     69      73       75       73         67    63      83             79
            ventilation fan (154-PF-E)
            lease automatic custody transfer building
 BU-6005                                                      29     44       57     71      75       77       75         69    65      85             81
            ventilation fan (194-PF-E)
            lease automatic custody transfer building
                                                              35     47       44     68      78       81       77         66    52      86             84
            louvre
            recycle oil pump building roof                    46     60       72     81      89       93       92         88    78      99             97
            recycle oil pump building wall                    49     62       74     83      91       95       95         90    81     101         100
            recycle oil pump building ventilation fan         27     42       55     69      73       75       73         67    63      83             79
 BU-6006
            recycle oil pump building louvre                  25     38       50     59      68       71       71         66    57      77             76
            glycol heater building roof                       64     77       90     99     108      111      111     106       96     117         116
            glycol heater building wall                       67     80       93    102     110      114      113     108       99     120         118
            glycol heater building ventilation fan (124-PF-
                                                              20     35       48     62      66       68       66         60    56      76             72
            E)
 BU-7101
            glycol heater building ventilation fan (194-PF-
                                                              31     46       59     73      77       79       77         71    67      87             83
            E)
            glycol heater building louvre                     38     52       64     73      82       85       85         80    70      91             90
 BU-7102    glycol heater building ventilation fan            31     46       59     73      77       79       77         71    67      87             83




                                                                      Volume 3
EnCana FCCL Ltd.                                                           - 31 -                                           Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                                                            Appendix 3-VI
Phases 1E, 1F and 1G                                                                                                                  October 2009


Table 8        Sound Power Level at Octave Band Centre Frequency for Application Case Building Sound Emission
               Sources (continued)
                                                                       Sound Power Level at Octave Band Centre Frequency
   Tag                                                                                                                                        Overall
                             Source Name                                                  [Hz], [dBA]
  Number
                                                               31.5   63       125   250      500    1,000    2,000   4,000     8,000   [dB]       [dBA]
            glycol heater building wall                        73     81       87     86      90       93       96         96    90     114         101
 H-7300     glycol heater building heater blower               61     71       72     75      81       85       88         89    84     103             93
            glycol circulation pump building roof              62     75       88     97     106      109      109     104       94     115         114
            glycol circulation pump building wall              65     78       91    100     109      112      112     107       97     118         117
            glycol circulation pump building ventilation fan
                                                               31     46       59     73      77       79       77         71    67      87             83
 BU-7103    (194-PF-E)
            glycol circulation pump building louvre            38     51       64     73      81       85       84         80    70      91             89
            instrument air package building roof               51     53       71     84      88       82       85         85    79      98             93
            instrument air package building wall               54     56       74     87      91       85       88         88    82     101             96
            instrument air package building ventilation fan    29     44       57     71      75       77       75         69    65      85             81
 BU-7221    instrument air package building louvre             34     37       55     67      71       66       69         68    63      81             76
            steam blowdown/storm water pond pump
                                                               44     57       70     79      87       91       90         85    76      97             95
            building roof
            steam blowdown/storm water pond pump
                                                               46     59       72     81      89       93       92         87    78      99             97
            building wall
            steam blowdown/storm water pond pump
 BU-7702                                                       20     35       48     62      66       68       66         60    56      76             72
            building ventilation fan
            steam blowdown/storm water pond pump
                                                               20     34       46     55      64       67       67         62    52      73             72
            building louvre
 BU-7834    emergency generator building ventilation fan       27     42       55     69      73       75       73         67    63      83             79
 BU-7835    emergency generator building ventilation fan       27     42       55     69      73       75       73         67    63      83             79




                                                                       Volume 3
EnCana FCCL Ltd.                                        - 32 -                    Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                  Appendix 3-VI
Phases 1E, 1F and 1G                                                                        October 2009

Table 9         Baseline Case Building Wall and Roof Height Summary
                                                                                     Wall and Roof Height
   Tag Number                                 Building Name
                                                                                              [m]
          –       air compressor building (CK-531A)                                          3
          –       air compressor building (CK-531B)                                          3
          –       diluent pump building (P-303A/B)                                           4
          –       glycol boiler building                                                    12
          –       induced gas flotation pump building                                       12
          –       east pump building                                                        12
          –       west pump building                                                        12
          –       sap compressor unit                                                       12
                  once through steam generator building stack                               27
 B-1725
                  once through steam generator building                                      6
                  once through steam generator building stack (B-101)                       25.9
 BU-0101          once through steam generator building stack (B-102)                       15.2
                  once through steam generator/make-up water treatment building              9.7
 BU-0101
                  make-up water treatment building addition                                  9.9
 (addition)
 BU-0106          produced water treatment warm lime softener building                       8.6
 BU-0107          recycle oil pump building                                                  7.7
 BU-0301          production building                                                       14
 BU-0302          gravity separator building                                                 8.7
 BU-0319          pump building                                                              4
 BU-1001          deoiling building                                                          7.3
 BU-1002          deoiling building                                                          7.3
 BU-1005          water/oil recycle pump building                                            5
 BU-1007          deoiling area chemical lab building                                        3
 BU-1009          regeneration waste pump building                                           3
 BU-1010          regeneration waste pump building                                           6
 BU-1501          produced water treatment building                                          8
 BU-1701          warm lime softener building                                                8.1
                  steam generator stack (B-2100/B-2200/B-2300/B-2400)                       27
 BU-2001
                  steam generator building                                                   9
 BU-2003          boiler feed water charge pump/steam separator building                     4.4
 BU-2004          boiler feed water charge pump/steam separator building                     8.4
 BU-2007          boiler feed water booster pump/steam separator building                    7
 BU-2008          steam area chemical lab building                                           3
                  steam generator stack (B-2500/B-2600/B-2700/B-2800)                       27
 BU-2501
                  steam generator building                                                   9
 BU-4001          free water knock out/treater building                                     11
 BU-4002          free water knock out/treater building                                     11
 BU-4004          desand/decant pump building                                                5
 BU-4005          inlet degasser building                                                   12
 BU-4006          treater area chemical lab building                                         3
 BU-5001          crude flash drum building                                                  8




                                                    Volume 3
EnCana FCCL Ltd.                                             - 33 -    Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                       Appendix 3-VI
Phases 1E, 1F and 1G                                                             October 2009


Table 9              Baseline Case Building Wall and Roof Height Summary (continued)
                                                                          Wall and Roof Height
    Tag Number                                     Building Name
                                                                                   [m]
 BU-6001               crude flash drum building                                  5.8
 BU-6003               recycle oil pump building                                  5
 BU-6005               lease automatic custody transfer building                  5.3
 BU-6006               slop area lab building                                     3
 H-7100                glycol heater building                                     6
 BU-7101               glycol heater building                                     8.4
 H-7200                glycol heater building                                     6
 BU-7220               instrument air package building                            4.7
 BU-7701               steam blowdown/storm water pond pump building              4
 BU-7801               25k V switch gear building                                 4
 BU-7802               motor control centre building                              4
 BU-7803               motor control centre building                              4
 BU-7804               motor control centre building                              4
 BU-7806               motor control centre building                              4
 BU-7807               motor control centre building                              4
 BU-7809               motor control centre building                              4
 BU-7814               electrical building                                        4
 BU-7815               electrical building                                        4
 BU-7817               electrical building                                        3
 BU-7818               electrical building                                        3
 BU-7823               electrical building                                        4
 BU-7824               electrical building                                        4
– = Not available.



Table 10             Application Case Building Wall and Roof Height Summary
                                                                          Wall and Roof Height
    Tag Number                                     Building Name
                                                                                   [m]
  BU-0101              make-up water treatment building                          10
  BU-0861              produced water treatment building                          8
  BU-0862              water/recycle oil pump building                            7
  BU-0863              deoiling building                                          9
  BU-0864              deoiling area chemical lab building                        3.2
  BU-0865              warm lime softener building                                9.6
  BU-0867              make-up water treatment building                          10
  BU-0868              deoiling building                                          9
  BU-0869              warm lime softener building                                9.6
  BU-0871              produced water treatment building                          8
  BU-0872              regeneration water pump building                           4
  BU-1003              deoiling building                                          9
  BU-1006              water/oil recycle pump building                            7
  BU-1008              deoiling area lab building                                 3.2
  BU-1801              warm lime softener building                                9.6
  BU-1901              produced water treatment building                          8



                                                         Volume 3
EnCana FCCL Ltd.                                   - 34 -                   Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                            Appendix 3-VI
Phases 1E, 1F and 1G                                                                  October 2009


Table 10        Application Case Building Wall and Roof Height Summary
                (continued)
                                                                               Wall and Roof Height
   Tag Number                             Building Name
                                                                                        [m]
 BU-2005          boiler feed water charge pump/steam separator building             10.3
 BU-2007          boiler feed water booster pump/steam separator building             7
 BU-2009          steam area chemical lab building                                    3.2
 BU-3003          boiler feed water charge pump/steam separator building             10.3
 BU-3004          boiler feed water charge pump/steam separator building             10.3
 BU-3007          boiler feed water booster pump/steam separator building             7
 BU-3008          steam area chemical lab building                                    3.2
 BU-3098          chelant injection package building                                  4.5
 BU-3099          sulphite injection package building                                 5
 BU-3101          steam generator building                                            9.3
 BU-3102          steam generator building                                            9
 BU-3103          steam generator building                                            9
 BU-4003          free water knock out/treater building                              11
 BU-4007          free water knock out/treater area chemical lab building             3.2
 BU-4008          desand/decant pump building                                         5
 BU-4009          inlet degasser building                                             7.3
 BU-4010          free water knock out/treater building                              11
 BU-4011          free water knock out/treater building                              11
 BU-4012          treater area chemical lab building                                  3.2
 BU-5002          crude flash drum building                                          10.5
 BU-6001          diluent pump building                                               5.8
 BU-6002          diluent pump building                                               5.7
 BU-6003          lease automatic custody transfer building                           5.3
 BU-6004          slop area chemical lab building                                     3.2
 BU-6005          lease automatic custody transfer building                           5.3
 BU-6006          recycle oil pump building                                           6
 BU-7101          glycol heater building                                              8.4
 BU-7102          glycol heater building                                              4
 H-7300           glycol heater building                                              6
 BU-7103          glycol circulation pump building                                    8.4
 BU-7221          instrument air package building                                     4.7
 BU-7702          steam blowdown/storm water pond pump building                       2.8
 BU-7834          emergency generator building                                        5
 BU-7835          emergency generator building                                        5




                                                Volume 3
  EnCana FCCL Ltd.                                      - 35 -                         Noise Modelling Methods
  Christina Lake Thermal Expansion Project,                                                     Appendix 3-VI
  Phases 1E, 1F and 1G                                                                           October 2009


  4               SPECTRAL RESULTS, HUNTER/TRAPPER
                  CABIN A

                         Table 11 lists the spectral noise results at Hunter/Trapper Cabin A which is the
                         most critical noise receptor among all receptors. The results are ranked in
                         descending order for the first 50 sources with the greatest contribution.

  Table 11               Noise Source Ranking at Critical Receptor – Hunter/Trapper Cabin A
                                               Total     Predicted Sound Level at Octave Band Centre Frequency
            Equipment                                                           [Hz], [dB]
Ranking                           Tag ID       Level
              Name
                                               dBA      31.5   63    125   250   500   1,000   2,000   4,000   8,000
          once through
          steam
          generator/make-
   1                          BU-0101           23       8     13    12    18    18     14       0      0       0
          up water
          treatment
          building roof
          inlet vapour air
   2                          AC-4060A/B/C      23       0     13    15    17    16     15       1      0       0
          cooler inlet
          glycol air cooler
   3                          AC-7150J/K/L/M    21       0     12    13    15    15     14       1      0       0
          inlet
   4      worker’s camp                –        21       0     15     8     5    11     16      14      0       0
          steam generator
   5                          E-2135            20       0       9    7    14    16     15       0      0       0
          air inlet
          steam generator
   6                          E-2235            20       0       9    6    14    15     15       0      0       0
          air inlet
          steam generator
   7                          E-3135            20       0       8    6    14    15     15       0      0       0
          air inlet
          glycol air cooler   AC-
   8                                            20       0     10    12    14    13     12       0      0       0
          inlet               7150E/F/G/H
          combustion air
   9                          K-8912A           19       0       6    9    12    14     14       4      0       0
          blower/motor
          combustion air
  10                          K-8912B           19       0       6    9    12    14     14       4      0       0
          blower/motor
          combustion air
  11                          K-8912A           19       0       6    9    12    14     14       4      0       0
          blower/motor
          combustion air
  12                          K-8912B           19       0       6    9    12    14     14       4      0       0
          blower/motor
          steam generator
  13                          E-2335            19       0       9    6    13    14     13       0      0       0
          air inlet
          steam generator
  14                          E-2435            19       0       9    6    13    14     13       0      0       0
          air inlet
          steam generator
  15                          E-2535            18       0       8    5    12    13     12       0      0       0
          air inlet
          lean amine
  16                          AC-8874           18       0       7   10    13    12     11       0      0       0
          cooler outlet
          lean amine
  17                          AC-8874           18       0       7   10    13    12     11       0      0       0
          cooler outlet
          production
  18                          BU-0301           18       0       0    8    14     9     13       0      0       0
          building wall
          lean amine
  19                          AC-8874           18       0       8   10    12    12     11       0      0       0
          cooler inlet




                                                       Volume 3
  EnCana FCCL Ltd.                                       - 36 -                         Noise Modelling Methods
  Christina Lake Thermal Expansion Project,                                                      Appendix 3-VI
  Phases 1E, 1F and 1G                                                                            October 2009


  Table 11            Noise Source Ranking at Critical Receptor – Hunter/Trapper Cabin A
                      (continued)
                                                Total     Predicted Sound Level at Octave Band Centre Frequency
            Equipment                                                            [Hz], [dB]
Ranking                           Tag ID        Level
              Name
                                                dBA      31.5   63    125   250   500   1,000   2,000   4,000   8,000
          glycol boiler
  20                                   –         17       0     10    16     7     5      1       0      0       0
          building wall
          once through
  21      steam generator     B-1725             17       5       9    9    14     7      4       0      0       0
          building stack
          glycol air cooler   AC-7350
  22                                             17       0       8   10    12    11      8       0      0       0
          inlet               A/B/C/D/E/F/G/H
          compressor
  23                          AC-8825            17       0       8    9    11    11     10       0      0       0
          aftercooler inlet
          compressor
  24                          AC-8825            17       0       8    9    11    11     10       0      0       0
          aftercooler inlet
          steam generator
  25                          B-2100             16       4       8    8    13     6      3       0      0       0
          stack
          steam generator
  26                          B-2400             16       4       8    8    13     6      2       0      0       0
          stack
          steam generator
  27                          B-2300             16       4       8    8    13     6      2       0      0       0
          stack
          steam generator
  28                          B-2500             16       4       8    8    13     6      2       0      0       0
          stack
          steam generator
  29                          B-2600             16       4       8    8    13     6      2       0      0       0
          stack
          steam generator
  30                          BU-2001            16       0       6   10     9     9     10       0      0       0
          building roof
          steam generator
  31                          BU-2001            16       0       7    9     8     9     10       0      0       0
          building wall
          steam generator
  32                          B-2700             16       4       8    8    13     6      2       0      0       0
          stack
          steam generator
  33                          B-2800             16       4       8    8    13     6      2       0      0       0
          stack
          steam generator
  34                          B-3100             16       4       8    8    13     6      2       0      0       0
          stack
          steam generator
  35                          B-3200             16       4       8    8    13     6      2       0      0       0
          stack
          steam generator
  36                          BU-2501            16       0       6    9     8     9     10       0      0       0
          building roof
          steam generator
  37                          BU-2700            16       4       8    8    13     5      2       0      0       0
          stack
          steam generator
  38                          BU-3101            16       0       6    9     8     9     10       0      0       0
          building roof
          steam generator
  39                          E-2835             16       0       8    4    11    11      8       0      0       0
          air inlet
          lean amine
  40      condenser           AC-8862            16       0       5    7    11    10      8       0      0       0
          outlet
          steam generator
  41                          E-2635             16       0       8    4    10    10      8       0      0       0
          air inlet
          steam generator
  42                          E-2735             16       0       8    4    10    11      8       0      0       0
          air inlet
          production
  43                          BU-0301            16       0       0    5    12     7     10       0      0       0
          building wall




                                                        Volume 3
     EnCana FCCL Ltd.                                  - 37 -                         Noise Modelling Methods
     Christina Lake Thermal Expansion Project,                                                 Appendix 3-VI
     Phases 1E, 1F and 1G                                                                       October 2009


     Table 11            Noise Source Ranking at Critical Receptor – Hunter/Trapper Cabin A
                         (continued)
                                              Total     Predicted Sound Level at Octave Band Centre Frequency
                Equipment                                                      [Hz], [dB]
 Ranking                             Tag ID   Level
                  Name
                                              dBA      31.5   63    125   250   500   1,000   2,000   4,000   8,000
             glycol air cooler
    44                           AC-7150M      15       0       5    7    10    10      8       0      0       0
             outlet
             glycol air cooler
    45                           AC-7150J      15       0       5    7    10    10      8       0      0       0
             outlet
             glycol air cooler
    46                           AC-7150K      15       0       5    7    10    10      8       0      0       0
             outlet
             glycol air cooler
    47                           AC-7150L      15       0       5    7    10    10      8       0      0       0
             outlet
             glycol air cooler
    48                           AC-7150H      15       0       4    7    10     9      8       0      0       0
             outlet
             steam generator
    49                           BU-2501       15       0       7    8     8     8      9       0      0       0
             building wall
             steam generator
    50                           E-3535        15       0       6    3     9    10      9       0      0       0
             air inlet
– = Not available.




                                                      Volume 3
EnCana FCCL Ltd.                                         - 38 -                          Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                         Appendix 3-VI
Phases 1E, 1F and 1G                                                                               October 2009


5               PERMISSIBLE SOUND LEVEL CALCULATIONS

                    Permissible Sound Level (PSL) criteria for the identified receptors were
                    calculated using the detailed methodology set out in Directive 038 (EUB 2007).
                    Tables 12 and 13 detail the calculations for the Project.

Table 12           Permissible Sound Levels at Hunter/Trapper Cabins A, B and
                   Christina Lake Lodge
                         Basic Nighttime Sound Level [dBA]
                                               Dwelling Unit Density
                                                                                          Nighttime    Daytime
       Proximity to                          (# per ¼ section of land)
                                                                                            [dBA]       [dBA]
      Transportation              1 to 8                 9 to 160            >160
                                 Dwellings              Dwellings          Dwellings
 Category 1                          40                     43                 46           40           40
 Category 2                          45                     48                 61           n/a          n/a
 Category 3                          50                     53                 56           n/a          n/a
 Basic Sound Level (BSL)                                                                    40           40
                                 Daytime Adjustment
                                                                             Value        Nighttime    Daytime
                        Reason for Adjustment                              [dBA Leq]

 adjustment for nighttime hours (22:00 to 07:00)                                0             0          n/a
 adjustment for daytime hours (07:00 to 22:00)                                +10            n/a         10
 nighttime/daytime adjustment                                                                 0          10
                                 Class A Adjustment
                                                                             Value        Nighttime    Daytime
           Class                     Reason for Adjustment                 [dBA Leq]
                            seasonal adjustment (November 1 to
 A1                                                                             +5           n/a         n/a
                            March 31)
                            absence of both tonal and impulse/impact
 A2                                                                             +5           n/a         n/a
                            components
                            ambient monitoring adjustment depending
 A3                         on the difference between the BSL and           -10 to +10       0            0
                            the measured Leq.
 class adjustment = sum of A1, A2 and A3 (as applicable), but is not to exceed a
 maximum of 10 dBA Leq
 Total Class A Adjustments                                                                   0            0
                                 Class B Adjustment
                                                                             Value        Nighttime    Daytime
           Class                       Duration of Activity                [dBA Leq]

 B1                        1 day                                              +15           n/a          n/a
 B2                        1 week                                             +10           n/a          n/a
 B3                        ≤2 months                                           +5           n/a          n/a
 B4                        >2 months                                            0            0             0
 Class B adjustment = one of B1, B2, B3 or B4                                               n/a          n/a
 Class B adjustment                                                                          0             0
 Permissible Sound Level (PSL) (dBA)                                                        40           50
n/a = Not applicable.
Note: Shaded fields are selected values used in the PSL calculation.




                                                      Volume 3
EnCana FCCL Ltd.                                         - 39 -                         Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                                        Appendix 3-VI
Phases 1E, 1F and 1G                                                                              October 2009

Table 13           Permissible Sound Levels at Conklin
                         Basic Nighttime Sound Level [dBA]
                                                Dwelling Unit Density
                                                                                         Nighttime    Daytime
       Proximity to                           (# per ¼ section of land)
                                                                                           [dBA]       [dBA]
      Transportation               1 to 8                 9 to 160           >160
                                  Dwellings              Dwellings         Dwellings
 Category 1                           40                     43               46            43          43
 Category 2                           45                     48               61            n/a         n/a
 Category 3                           50                     53               56            n/a         n/a
 Basic Sound Level (BSL)                                                                    43          53
                                 Daytime Adjustment
                                                                             Value       Nighttime    Daytime
                        Reason for Adjustment                              [dBA Leq]

 adjustment for nighttime hours (22:00 to 07:00)                                   0         0          n/a
 adjustment for daytime hours (07:00 to 22:00)                               +10            n/a         10
 nighttime/daytime adjustment                                                                0          10
                                  Class A Adjustment
                                                                             Value       Nighttime    Daytime
           Class                      Reason for Adjustment                [dBA Leq]

                             seasonal adjustment (November 1 to
 A1                                                                           +5            n/a         n/a
                             March 31)
                             absence of both tonal and impulse/impact
 A2                                                                           +5            n/a         n/a
                             components
                             ambient monitoring adjustment depending
 A3                          on the difference between the BSL and         -10 to +10        0           0
                             the measured Leq.
 class adjustment = sum of A1, A2 and A3 (as applicable), but is not to exceed a
 maximum of 10 dBA Leq

 Total Class A Adjustments                                                                   0           0
                                  Class B Adjustment
                                                                             Value       Nighttime    Daytime
           Class                         Duration of Activity              [dBA Leq]

 B1                          1 day                                           +15            n/a         n/a
 B2                          1 week                                          +10            n/a         n/a
 B3                          ≤2 months                                        +5            n/a         n/a
 B4                          >2 months                                             0         0           0
 Class B adjustment = one of B1, B2, B3 or B4                                               n/a         n/a
 Class B adjustment                                                                          0           0
 Permissible Sound Level (PSL) [dBA]                                                        43          53
n/a = Not applicable.
Note: Shaded fields are selected values used in the calculation.




                                                      Volume 3
EnCana FCCL Ltd.                             - 40 -                 Noise Modelling Methods
Christina Lake Thermal Expansion Project,                                    Appendix 3-VI
Phases 1E, 1F and 1G                                                          October 2009


6           REFERENCES

            Cowan, P.J. 1994. Handbook of Environmental Acoustics. Van Nostrand Heinhold.
                   New York, NY. 180 pp.

            Datakustik. 2006.    Computer Aided Noise Abatement Model Version 3.6.
                   DataKustik GmbH. Munich, Germany.

            Drew, T., D. daSilva and C. Decock. 2005. Community Noise Models – Do They
                   Work? A Case Study. Alberta Acoustical Society 2005 Spring Conference,
                   Banff Alberta.

            EUB (Alberta Energy and Utilities Board). 2007. Directive 038: Noise Control
                  Directive.

            ISO (International Organization for Standardization). 1996. ISO 9613: Acoustics –
                    Attenuation of Sound During Propagation Outdoors Geneva, Switzerland.

            OE (Ontario Ministry of the Environment). 1989. ORNAMENT (Ontario Road
                  Noise Analysis Method for Environmental and Transportation). Technical
                  Document. Prepared by the Air and Noise Section, Environmental
                  Assessment and Approvals Branch, Ontario Ministry of the Environment.
                  Queens Printer for Ontario.

            OE. 1999. Environmental Noise Assessment in Land Use Planning – a Manual for
                  the Noise Assessment in Land Use Planning Course. Prepared by the Air
                  and Noise Section, Environmental Assessment and Approvals Branch,
                  Ontario Ministry of the Environment. Queens Printer for Ontario.




                                            Volume 3
 EnCana FCCL Ltd.                             - 41 -                    Noise Modelling Methods
 Christina Lake Thermal Expansion Project,                                       Appendix 3-VI
 Phases 1E, 1F and 1G                                                             October 2009


 7             GLOSSARY

Alberta Environment           Provincial ministry that looks after the following: establishes
(AENV)                        policies, legislation, plans, guidelines and standards for
                              environmental management and protection; allocates resources
                              through approvals, dispositions and licenses, and enforces those
                              decisions; ensure water infrastructure and equipment are maintained
                              and operated effectively; and prevents, reduces and mitigates floods,
                              droughts, emergency spills and other pollution-related incidents.

Anthropogenic                 Caused by human activity.

Ambient                       The conditions surrounding an organism or area.

Application Case              The Environmental Impact Assessment (EIA) case including the
                              Project that is the subject of the application, existing environmental
                              conditions, and existing and approved projects or activities.

Attenuation                   The process by which a compound is reduced in concentration over
                              time, through adsorption, degradation, dilution and/or
                              transformation.

Baseline Case                 The Environmental Impact Assessment case that includes existing
                              environmental conditions as well as existing and approved projects
                              or activities.

Boreal Forest                 The northern hemisphere, circumpolar, tundra forest type consisting
                              primarily of black spruce and white spruce with balsam fir, birch
                              and aspen.

“C-weighted” Decibel (or      A frequency-weighting in which the low frequencies are included
dBC)                          more than with A-weighting, making this unit useful in determining
                              potential for low frequency noise impacts.

dBA                           A decibel value which has been A-weighted, or filtered to match the
                              response of the human ear.

Decibel (dB)                  The standard unit of measure, in acoustics. A logarithmic ratio of
                              the measured pressure fluctuation and reference pressure.

Diluent                       A light liquid hydrocarbon added to bitumen to lower viscosity and
                              density. The thinning agent is used by the oil sands to make heavy
                              oil more fluid so it can be transported.




                                             Volume 3
 EnCana FCCL Ltd.                             - 42 -                    Noise Modelling Methods
 Christina Lake Thermal Expansion Project,                                       Appendix 3-VI
 Phases 1E, 1F and 1G                                                             October 2009


Energy Resources              An independent, quasi-judicial agency of the Government of Alberta,
Conservation Board            the EUB was created in February 1995 by the amalgamation of the
(ERCB)                        Energy Resources Conservation Board and the Public Utilities
                              Board. The purpose of the EUB is to ensure that the discovery,
                              development, and delivery of Alberta’s resources take place in a
                              manner that is fair, responsible and in the public interest.

Equivalent Noise Level        A logarithmic average of the measured or predicted noise levels over
(Leq)                         a given period of time. This type of average takes into account the
                              natural variability of sound.

Frequency                     The human ear does not respond to all frequencies in the same way.
                              Mid-range frequencies are most readily detected by the human ear,
                              while low and high frequencies are harder to hear. Environmental
                              noise levels are usually presented as “A-weighted” decibels (or
                              dBA), which incorporates the frequency response of the human ear.

Local Study Area (LSA)        Defines the spatial extent directly or indirectly affected by the
                              Project.

Low Frequency Noise           Where a clear tone is present below and inclusive of 250 Hz. Low
(LFN)                         frequency noise can be determined by subtracting the overall C-
                              weighted from the overall A-weighted sound level, or as the overall
                              C-weighted sound level by itself.

Muskeg                        A soil type comprised primarily of organic matter. Also known as
                              bog peat.

Noise                         The levels that can be heard or measured at a receptor.

Permissible Sound Level       The allowable overall A-weighted sound level of noise from energy
(PSL)                         industry sources, as specified by the EUB Noise Control Directive,
                              which may contribute to the sound environment of a residential
                              location.

Planned Development           The Planned Development Case includes the Application Case
Case (PDC)                    components and planned developments that have been publicly
                              disclosed at least six months prior to submission of the
                              Environmental Impact Assessment.

Receptor (Noise)              A location where measurements or predictions of noise levels are
                              made.




                                             Volume 3
 EnCana FCCL Ltd.                              - 43 -                    Noise Modelling Methods
 Christina Lake Thermal Expansion Project,                                        Appendix 3-VI
 Phases 1E, 1F and 1G                                                              October 2009


Regional Study Area           Defines the spatial extent related to the cumulative effects resulting
(RSA)                         from the Project and other regional developments.

Relative Humidity             The ratio of the amount of water vapour in the atmosphere to the
                              amount necessary for saturation at the same temperature. Relative
                              humidity is expressed in terms of percent and measures the
                              percentage of saturation.

Sound                         The acoustic energy generated by natural or anthropogenic sources,
                              including Project activities

Sound Power Level (Lw)        the level of sound power, expressed in decibel (dB) relative to a
                              stated reference value of 10-12 watts.

Sound Pressure Level (Lp)     The sound pressure at a given point quantified by:
                              Lp = 10 log10(prms/pref)2
                              Where prms is the root mean square, sound pressure and pref is the
                              reference rms sound pressure (dB re 20µPa). “Sound pressure” is
                              the difference between the instantaneous pressure at a fixed point in
                              a sound field, and the pressure at the same point with the sound
                              absent.

Volume                        A sound or noise expressed on a logarithmic scale, in units called
                              decibels (dB). Since the scale is logarithmic, a sound or noise that is
                              perceived as twice as loud as another will only be three decibels (3
                              dB) higher. A sound or noise with double the number of decibels
                              will be perceived as more than twice as loud. A three decibel (3 dB)
                              change is also the average threshold at which the human ear can
                              detect a change in volume.




                                             Volume 3
 EnCana FCCL Ltd.                             - 44 -            Noise Modelling Methods
 Christina Lake Thermal Expansion Project,                               Appendix 3-VI
 Phases 1E, 1F and 1G                                                     October 2009


 8           ABBREVIATIONS

°C                        Temperature in degrees Celsius
>                         More than
±                         Plus or minus
≤                         Less than or equal to
AENV                      Alberta Environment
bbl/d                     Barrels per day
BSL                       Basic Sound Level
BSL                       Basic sound level
CadnaA                    Computer Aided Noise Attenuation
CLTP                      Christina Lake Thermal Project
dB                        Decibel, a measure of sound power
dBA                       A-weighted Decibels
dBC                       C-weighted Decibels
e.g.                      For example
EIA                       Environmental Impact Assessment
EnCana                    EnCana FCCL Ltd.
ERCB                      Energy Resources Conservation Board
EUB                       Alberta Energy and Utilities Board
Hz                        Hertz
IL                        Insertion Loss
km                        Kilometre
km/hr                     Kilometres per hour
KV                        Kilovolt
kV                        Kilovolt
KW                        Kilowatt
Leq                       Equivalent continuous sound level
LFN                       Low Frequency Noise
LSA                       Local Study Area
Lw                        Sound Power Level
m                         Metre
m3/d                      Cubic metres per day
PDC                       Planned Development Case
PSL                       Permissible Sound Level
Rg                        Range
RSA                       Regional Study Area



                                             Volume 3
EnCana FCCL Ltd.                             - 45 -        Noise Modelling Methods
Christina Lake Thermal Expansion Project,                           Appendix 3-VI
Phases 1E, 1F and 1G                                                 October 2009

SAGD                     Steam Assisted Gravity Drainage
SRF                      Sulphur Recovery Facility