Document Sample
scope of work template
							Slip rings
modular transmission of current and signals


 Slip rings IST-SR085

                                     Description:
                                     In general slip rings are used to transmit po-     The construction is modular and offers the
                                     wer, signal or data from a stationary to a ro-     greatest flexibility in a variety of applications.
                                     tating platform. The transmission between
                                     the stator and rotor takes place via sliding
                                     contacts and is extremely reliable.

                                     Advantages:                                        Application areas for Slip Rings:
                                     • Rugged design for industrial use                 • Packaging machines
                                     • Modular system construction                      • Printing machines
                                     • Two-cavity system for load- and signal trans-    • Textile machines (spinning machines)
                                       mission                                          • Special purpose machines
                                     • Available in open or encapsulated design         • Robots and handling equipment
                                     • Protection rating for encapsulated model         • Machine tools ( jig grinding machines)
                                       IP 50 to IP 64                                   • Lifting platforms
                                     • Long service life                                • Cranes
                                     • Individually replaceable brush rings             • Cable reels
                                     • Replaceable rotors                               • Pipeline inspection systems
                                     • Load and signal channels can be combined           (down hole equipment)
                                       selectively                                      • Video surveillance (CCTV) equipment
                                     • Variable overall length depending on the         • Medical technology (Magnetic resonance
                                       number of channels                                 imaging – MRI)
                                     • Customer-specific modifications possible         • Fairground rides
                                                                                        • Off-shore technology



Modular construction:




                                     Stator ring with pick-off            Stator ring’ with pick-off
                                     spring for load-currents             spring for signal currents




                                     Insulator with slip ring        Insulator with slip rings
                                     for signal currents             for load currents

Technical Data:
 Dimensions:                         see drawing
 Overall length:                     dependent on number of transmission paths
 Bore diameter:                      up to ø 30 mm
 Current loading:                    max. 25 A (at 240 V AC)
 Voltage:                            400 V AC (dependent on load)
 Contact resistance load channel:    < 0,1 Ohm
                                     –
 Contact resistance signal channel   < 0,1 Ohm
                                     –6
 Insulation resistance at 500 VDC:   10 MΩ
 Dielectric strength:                1000 V eff. (60 sec.)
 Speed:                              max. 800 1/min
 Operating temperature:              0 ... 80 °C
 Protection rating:                  IP 50 up to IP 64 on request
Slip rings
modular transmission of current and signals


 Slip rings IST-SR085



Dimensions:                                                                                Klemmanschlüsse f. Last ohne
                                                                                            3
                                                                                           Drahtschutz, mit Berührungsschutz
Example type IST-SR085-2-3-V14                                                                         4
                                                                                                      Aderzuführung f. Last
                                                                                                      beidseitig möglich                                      10
                                                                                                                                                               Drehmomentstütze

                                                                                                                          5
                                                                                                                          Klemmanschluss                                     8 +0,1
                                                                                                                          Signalübertragung
                                    Anschlussschraube M5              5                                                  rotierender
                                     1
                                    für Lastübertragung                                                                    6
                                                                                                                         Anschlussring
                                                                                                                                                                                        5.5
                                                                                                                                                                                      R4
                                                             5




                                                                                                                                                                                              60.4
                     1
                           2




                                                                                                                                           30
                               3




                                                           ÿ 43.4




                                                                                                                                           5.5




                                                                                                                                                                                              44.4
             5
                 4




                                                                          9
                               85




                                                                                 14
                                                                                                  114.7
                                                                                                            *
                                                                                                                                                                        F7
                                                                                                                         Schutzkappe f.                            25
                 78.8                                                                                                     9
                                                                                                                         Anschlüsse
                                                                          * Overall length depends on the                                                          82
                                                                7      number 914
                                                                Gewindestift DINof transmission paths
                                                                                                                   8
                                                                                                                  Wartungsfenster
           Anschlussschraube M4
            2
           für Signalübertragung                                M6x10 4 mal




 1 Screw terminal M5 for load transmission                          4 Wire lead-in for load possible on both sides                       8 Window for maintenance
 2 Screw terminal M4 for signal transmission                        5 Terminal clamp for signal transmission                             9 Protective cover for connections
 3 Terminal clamp for load without wire protection,                 6 Rotating connection ring                                        10 Torque stop
   with shock-hazard touch protection                               7 4 x socket set screw DIN 914 M6 x 10




Additional ordering information:                                                                            Options on request:
• Operating voltage/ current, in each case continuous and transient                                         • Protection level up to IP 64
• For load transmission                                                                                     • Various connector and cable outlets
• Signal frequency                                                                                          • Various contact possibilities
• Signal type (e.g. angular sensor, strain-gauge, PT 100)                                                   • Various fixing options
• Speed                                                                                                     • Combinations with other components to create systems
• Bore diameter with tolerance specification                                                                • Encoders, air bushings, hydraulic bushings
• Design (modular or encapsulated and method of mounting)
• Mounting position
• Level of IP protection
• Rotor and stator connection type (e.g. connectors, cables,
  terminals)
• Description of the installation location and
  environmental conditions



Order code:                                  IST-SR085-XX-XX-XXX

 Type series                                                                                Version number
                                                                                            (will be allocated at time of ordering)
 Number of data channels
                                                                                            Number of power channels




                         Fritz Kübler GmbH Zähl- und Sensortechnik • Schubertstrasse 47 • D-78054 Villingen-Schwenningen
                         Phone +49 (0) 77 20-39 03-34 • Fax +49 (0) 77 20-215 54 • guenter.kahrs@kuebler.com • www.kuebler.com

						
Related docs
Other docs by nikeborome
DTU artefact
Views: 124  |  Downloads: 0
WCPT News March COPY
Views: 5  |  Downloads: 0
Minerals Not Rocks
Views: 93  |  Downloads: 0
UW Website Designers
Views: 1  |  Downloads: 0
feb web master
Views: 155  |  Downloads: 0
GURPS Metric
Views: 128  |  Downloads: 0