					Instructions for
Deep Fryers
Applicable to the following models:
Pension 1-94        [P1-94]                      Cantine 94                   [C-94]
Pension 1-94 Turbo [P1-94 T]                     Cantine 94 Turbo              [C-94 T]
Pension 2-94        [P2-94]                      Maxi 94                        [M-94]


Your model:
Please quote the details on this label
on all orders.

List of spare parts: see page 11



Your agent:




                              DECLARATION OF CONFORMITY
We,      manufacturer                Valentine Fabrique SA
                                     6, Avenue d’Epenex
                                     CH - 1024 ECUBLENS
                                     Tél.: +41 21 634 32 23          Fax: +41 21 635 90 66
hereby declare that these products comply with the following standards:
Machine Safety:           EN 60204-1 of 1992
Low Voltage Directive:    EN 60335-1 and EN 60335-2-37
EMC:                      EN 50081-1, 50082-1, EN 55011 and EN 55014
and comply with the Machine Safety Directives EN 89/392, Low Voltage Directive 73/23
as well as Electromagnetic Compatibility Directive 89 / 336 modified by Directive 92 / 31

Ecublens, 16 October 1995

Valentine Fabrique SA                            CEE Agent:

Name: M. F. Wenger                               Name: M. A. Holliday

Position: President                              Position: Director of Valentine Equipment LTD
                                                                       Reading RG1 8JS (GB)



Date de création: 13.11.95 par:LIE                 Date de modif.:                        Fichier DATA WORD IN

                      Fabrique SA                  Doc. No.:           IN-F94EA           Page No.:   1 / 13
                                     Table of contents
                                                                                                   Page No.:


1. Important note __________________________________________________________________ 3
1.1 Warnings_____________________________________________________________________________ 3
1.2 Inherent risks _________________________________________________________________________ 3
1.3 Periodic checks ________________________________________________________________________ 3
2. Technical specifications __________________________________________________________ 4
3. Installation_____________________________________________________________________ 4
3.1 Important precautions for installation ____________________________________________________ 4
3.2 Examples of installation ________________________________________________________________ 4
  3.2.1 Example of installation I (Fig. 1) ________________________________________________________________4
  3.2.2 Example of installation II (Fig. 2) _______________________________________________________________4
  3.2.3 Example of installation III (Fig. 3)_______________________________________________________________4
3.3 Cleaning (Fig. 4) ______________________________________________________________________ 4
4. Instructions for use ______________________________________________________________ 7
4.1 Filling with oil_________________________________________________________________________ 7
4.2 Starting up, cooking____________________________________________________________________ 7
4.3 How to save oil ________________________________________________________________________ 7
4.4 Conserving the oil______________________________________________________________________ 8
4.5 Servicing the deep fryer, changing the oil, cleaning __________________________________________ 8
5. Troubleshooting_________________________________________________________________ 9
5.1 Simple faults __________________________________________________________________________ 9
5.2 Complex faults ________________________________________________________________________ 9
5.3 Safety thermostat _____________________________________________________________________ 10
5.4 Safety switch _________________________________________________________________________ 10
5.5 Spare parts __________________________________________________________________________ 11
5.6 Wiring diagram ______________________________________________________________________ 11
5.7 Layout ______________________________________________________________________________ 13




Warning:
The information contained in these instructions for use may be modified without
warning. Valentine Fabrique SA cannot be held liable for any errors contained
in this document or for damage or injury resulting from use of this.



Date de création: 13.11.95 par:LIE               Date de modif.:                      Fichier DATA WORD IN

                      Fabrique SA                Doc. No.:         IN-F94EA           Page No.:   2 / 13
Dear Customer,
We congratulate you on your purchase of a Valentine deep fryer. This is a high quality
product renowned throughout Europe for over 50 years.

The instructions below take into account new legislation concerning product liability as well
as EU and international safety standards.


1. Important note

1.1 Warnings
Before using your deep fryer, please make sure you observe the following:

⇒      study and strictly follow the instructions given below

⇒      notify personnel on how to use the deep fryer correctly and draw their attention
       to inherent risks

Valentine Fabrique SA disclaims any liability for damage or injury caused by incorrect
use of the deep fryer and failure to comply with the operating instructions


1.2 Inherent risks                   • Hot oil can cause severe burns
                                       Avoid all direct contact with the body
                                     • Drain food well before frying
                                     • Never put water or ice in the oil. This will cause splashing and
                                       overflow of the pan
                                     • Do not put your face close to the hot oil when introducing foods
                                       into the pan
                                     • Keep away from steam and oil splashes
                                     • Never put anything other than food into the oil, for example gas
                                       cartridges, sealed tins, etc as this could cause explosion and
                                       splashes of burning oil
                                     • The deep fryer should not be operated without supervision. If
                                       start smoking, turn off (switch at position « 0 »)
                                     • The oil level should never fall below the "MIN" marker. If the
                                       level is too low (level with the heating element),
                                       the oil may catch fire
                                     • In the event of fire, do not use water to extinguish it
                                     • It is advisable to install a fire extinguisher near the deep fryer
                                       and have a fire blanket near at hand




1.3 Periodic checks
♦ Check regularly that the adjustable thermostat and the safety thermostat are operating
   properly (see 5.3)




Date de création: 13.11.95 par:LIE                   Date de modif.:                  Fichier DATA WORD IN

                      Fabrique SA                    Doc. No.:         IN-F94EA       Page No.:   3 / 13
2. Technical specifications
Model:                                       P1-94        P1-94 T           P2-94       C-94      C-94 T        M-94
Rating                               [kW]       7             11              14         14          22           21
3P+N+T conn. 400 V                     [A]     10             16              20         20          32           30
Frequency                            [Hz]    50 - 60       50 - 60          50 - 60    50 - 60    50 - 60       50 - 60


Capacity in litres                             6-8           7-9            2 x 6-8     15-18      15-18        25-28
Service thermostat                              1              1               2          1          1            1
Safety thermostat                               1              1               2          2          2            3
Timer                                           1              1               2          1          1            1


Output - frozen chips / h                     15 kg         23 kg            30 kg      30 kg      46 kg        45 kg
Output - unfrozen chips / h                   19 kg         29 kg            38 kg      38 kg      58 kg        56 kg


Leaktightness                                 IP X5         IP X5            IP X5      IP X5      IP X5         IP X5
Weight                               [kg]      28             28              46         41          41           58
Dimensions                           [cm]    25x57x80     25x57x80          40x57x80   40x57x80   40x57x80     60x57x80



3. Installation

3.1 Important precautions for installation
♦ The purchaser must have the deep fryer installed at his own cost by an approved dealer, in accordance with
  local regulations
♦ The voltage, frequency and current should comply with the information given on the rating plate on the deep
  fryer
♦ The deep fryer should in any case be connected to safety earth by the lead. The deep fryer is supplied with a
  hose cable 1,9 m in length
  Conductor colours:                         Earth :         yellow / green
                                                        Neutral:            blue
♦ In the case of the narrow format deep fryers P1-94 and P1-94T, there is a risk of tilting in the event of lateral
  impact. These models should be placed between 2 units or fixed at the sides
♦ Before connecting the power supply, set switch [E] to « 0 ». Never heat up without oil

3.2 Examples of installation
When cooking potato chips, a lot of steam is emitted. Proper extraction is therefore required.

3.2.1 Example of installation I (Fig. 1)
Wall plug [F] protected against vertical drops of water        or protected against splashes of water.

3.2.2 Example of installation II (Fig. 2)
Deep fryer positioned centrally against the stove, for example. Connecting bracket [H] with socket             or splash
protection.

3.2.3 Example of installation III (Fig. 3)
Junction box [J] with 4-pole 3P+N switch positioned above the deep fryer, with fixed cable. As this within the
steam flow path, the box should be leaktight.


3.3 Cleaning (Fig. 4)
When cleaning the floor and walls, the deep fryer can be pulled forwards [K]. The main lead should be quite
long.



Date de création: 13.11.95 par:LIE                        Date de modif.:                         Fichier DATA WORD IN

                      Fabrique SA                         Doc. No.:           IN-F94EA            Page No.:   4 / 13
      Fig. 1: Deep fryer positioned    Fig. 2: Deep fryer positioned in          Fig. 3: Deep fryer positioned
              against wall,                    centre (against stove)                    against wall,
             flush-mounted plug                                                           with junction box


A Extraction                                                        F Wall socket
B Wall or divider                                                   G Connecting lead 1,9 m
C Cover hooked onto edge of pan,                                    H Connecting bracket
  acts as a guard                                                   J Junction box with switch
D Rating plate with appliance number V, C and R                     K Deep fryer pulled forward for cleaning
E Switch                                                              walls and floors




                                            Fig. 4




Date de création: 13.11.95 par:LIE                Date de modif.:                           Fichier DATA WORD IN

                      Fabrique SA                 Doc. No.:            IN-F94EA             Page No.:   5 / 13
                                                                                   Fig. 5




                                                                    1   Cover
                                                                    2   Cooking chart
                                                                    3   Handle
                                                                    4   Rating plate
                                                                    5   Tray attachment
                                                                    6   Timer
                                                                    7   Yellow pilot lamp
                                                                    8   Clear pilot lamp
                                                                    9   Green pilot lamp
                             Detail of panels                      10   Switch
                                                                   11   Thermostat
                                                                   12   Door
                                                                   13   Slot for hooking on cover
                                                                   14   Heating element box
                                                                   15   Safety thermostat
                                                                   16   Heating element connection
                                                                   17   Connecting lead - 1,9 m
                                                                   18   Telescopic bar of heating element
                                                                   19   Level in basket
                                                                   20   Basket
                                                                   21   Cover hook
                                                                   22   Basket hook
                                                                   23   Draining tray
                                                                   24   Oil level
                                                                   25   Heating element coil
                                                                   26   Drainage cock button
                                                                   27   Filter
                                                                   28   Receptacle
                                                                   29   Thermostat probe




Date de création: 13.11.95 par:LIE              Date de modif.:                      Fichier DATA WORD IN

                      Fabrique SA               Doc. No.:         IN-F94EA           Page No.:   6 / 13
4. Instructions for use

4.1 Filling with oil
Lift cover [1] (see fig.5, p.6) by handle [3] ◊ The cover provides protection against oil spattering
and hook on by slots [13] onto the edges        behind
of the pan
Check that the heating coils [25] are all at ◊ The probe of the thermostat [29] should be between
the bottom                                     the heating coils. Never rest the heating element on
                                                      the probe
Fill the pan with ground-nut oil up to the oil ◊ Animal and vegetable fats that set when cold are not
level marker [24]                                recommended. If the use of fats cannot be avoided,
                                                      melt in a pan. Never melt blocks of solid fat on the
                                                      heating elements

After using each time, top up the oil level. If the oil level is too low, efficiency will be
lost and the oil will overheat.

4.2 Starting up, cooking
Turn the switch [10] to position «1»            ⇒ clear pilot lamp [8] lights up

Turn the thermostat button [11] to the ⇒ yellow pilot light comes on
required temperature, for example 180 o C
Wait for the green pilot lamp [9] to come ⇒ place directly in the heating element
on before immersing the basket in the oil
Set the cooking time on the timer [6], for ⇒ see cooking chart
example 3 minutes
As soon as the timer rings, lift the basket ⇒ Do not remove the basket from the pan, but shake
and place on the tray [23]                    horizontally on the tray. Then hook the back of the
                                                      basket [22] on the bottom of the cover [21]

The yellow pilot light will go out as soon as the thermostat cuts off the power.

Never overfill the basket,               ²                    • the oil cools down too quickly
always make sure the oil                                      • cooking takes too long
level is correct                     otherwise                • food becomes saturated with oil
        o
Temp. C Foods                               Minutes       Basket level
  190       frozen chips                    3 (1+1)               -1-
  160       blanching raw chips              4-6                  -3-
  190       cooking blanched chips           2-3                  -1-
  170       breaded meats                      3                  -2-
  170       frozen chicken legs              6-8                  -2-
  180       fish                             2-4                  -2-


4.3 How to save oil
∗ Do not leave deep fryer on before or after using (the fryer only takes 5 minutes to
   heat up). The high temperature destroys the oil also without food.
∗ Limit the temperature at 180 oC instead of 200 oC -> life time of oil plus 40 % !
∗ After each service, pass the oil through a microfilter (optional). This will retain even
   microscopic particles and can be reused many time over.




Date de création: 13.11.95 par:LIE           Date de modif.: 16.08.96                  Fichier DATA WORD IN

                      Fabrique SA            Doc. No.:            IN-F94EA             Page No.:    7 / 13
4.4 Conserving the oil
Filter oil after each use, while it is still warm.
Turn the switch [10] to position « 0 » and open the ⇒ Do not heat without oil!
door [12]. Open the valve by pulling hard on button
[26]. Let the oil run through to the filter [27] and into
                                                          ⇒ Remove, clean filter and tip oil back into
the receptacle [28]                                         the pan
After use, remove the cover from the edge of the ⇒ Cooking chart at back
pan and cover the deep fryer

4.5 Servicing the deep fryer, changing the oil, cleaning
The mechanical and electrical parts of the deep fryer do not required servicing. However,
thorough cleaning when oil is changed is strongly recommended. The oil should be replaced
as soon as it becomes dark brown in colour and starts to smoke (after about 20 to 50 hours'
use).
Waste oil must only be put into suitable containers and disposed of
according to local regulations.
Turn the switch [10] to position «0», and open the ⇒ let oil run out
door [12]. Remove the filter [27]. Empty the
                                                   ⇒ Replace
receptacle [28] and close the valve [26]
Pour boiling water containing detergent (soda, for ⇒ Leave for 10 to 30 minutes, wash the pan
example) into the pan to about 5 cm above the oil    and the heating element coil [25] using a
                                                     brush, lift up the heating element, turn and
level marker                                         place on the edge of the pan. Do not
                                                                    damage the probe of the thermostat with
                                                                    sharp or pointed tools
Clean the bottom part of the pan as well. Drain off ⇒ After cleaning, rinse the pan well with hot
water, wash the filter [27] and the receptacle [28]   water, as detergent residues are very
                                                                    harmful to the fresh oil used to refill the pan
Wipe the pan and the heating element with a dry ⇒ Replace the heating element in the correct
cloth. Close the valve [26] and refill the pan with position (right at the bottom with the
                                                    thermostat probe between the coils as
fresh oil to the level [24].                        described in point 4.1)



                        Unique advantages of your Valentine deep fryer:

                Higher performance due to ⇒ When the basket is immersed in the oil on the
                system dialogue (patented)  « green » light, the deep fryer continues to
                                                     heat without stopping and thus provides
                                                     maximum performance during peak times

                Programmed performance         ⇒ During quiet periods, the deep fryer works at
                (patented)                       half only, with consequent savings on oil and
                                                 electricity

                Super heating elements         ⇒ The extra long heating element made of
                                                 stainless steel does not burn the oil (surface
                                                                           o
                                                 temperature limited to 250 C)

                Thermostat                     ⇒ An ultra sensitive thermostat with fast
                                                 response     times    ensures     the correct
                                                 temperature. The probe of the thermostat is
                                                 located in the middle of the pan.




Date de création: 13.11.95 par:LIE              Date de modif.: 16.08.96                   Fichier DATA WORD IN

                      Fabrique SA               Doc. No.:          IN-F94EA                Page No.:   8 / 13
5. Troubleshooting

5.1 Simple faults

Faults                               Probable cause                            Solutions
Deep fryer does not heat up          ∗ No power                      ◊ Check fuses, plug and
                                                                       socket carefully
                                     ∗   Safety thermostat has       ◊ Reset by pressing the red
                                         triggered                     button with your finger
                                                                       (see 5.3)
                                                                     ◊ Check that the heating
                                     ∗   Safety switch has triggered   element is positioned
                                                                       correctly at the bottom of
                                                                       the pan (see 4.1)
Deep fryer does not get hot          ∗   One phase missing in        ◊ Check fuses
enough                                   power supply
Clear pilot lamp does not            ∗   Faulty bulb                 ◊ Change bulb
come on or flashes                   ∗   One phase missing in        ◊ Check fuses
                                         power supply
Yellow pilot lamp does not           ∗   Faulty bulb                 ◊ Change bulb
come on or flashes
Green pilot lamp does not            ∗ Faulty bulb                             ◊ Change bulb
come on or flashes


5.2 Complex faults

Faults                               Probable cause                            Solutions
 Pilot lamps are on but the          ∗ Faulty heating element                  ◊ Call After-Sales Service *
deep fryer does not heat up
Deep fryer does not get hot          ∗ Phase failure                           ◊ Call After-Sales Service *
enough                               ∗ Faulty element
Fuses blow on switching on           ∗ Short-circuit                           ◊ Call After-Sales Service *
Deep fryer triggers the circuit-     ∗ Moisture or faulty                      ◊ Call After-Sales Service *
breaker (FI)                           insulation in the electric
                                       circuit
Clear pilot lamp does not            ∗ Faulty switch                           ◊ Call After-Sales Service *
come on or flashes
Yellow pilot lamp does not           ∗ Faulty thermostat                       ◊ Call After-Sales Service *
come on or flashes
Green pilot lamp does not            ∗ Faulty thermostat                       ◊ Call After-Sales Service *
come on or flashes

* Important:
When calling the After Sales Service, please quote:                         - type of deep fryer
                                                                            - serial number
                                                                            - voltage, current and rating

You will find this information on page No 1 of this manual or on the rating plate
(see fig. 5 page 6).
You will save time and therefore additional costs.


Date de création: 13.11.95 par:LIE               Date de modif.: 16.08.96                  Fichier DATA WORD IN

                      Fabrique SA                Doc. No.:          IN-F94EA               Page No.:   9 / 13
5.3 Safety thermostat
The positive safety thermostat is located in the box of the heating element housing at the
back of the deep fryer (Fig 6).The red reset button projects from under the box.
                                                                               o
This is triggered:                   ∗ when the oil temperature exceeds 230 C
                                     ∗ when the capillary tube is damaged
                                     ∗ when the temperature falls below zero oC

or in the case of incorrect          ∗ when the appliance is heated without oil or the level is too
use:                                   low
                                     ∗ when the appliance is drained without releasing the switch
                                     ∗ when the heating element is not in the correct position at the
                                       bottom of the pan
                                     ∗ when the block of solid fat is melted directly on the heating
                                       element

To reset:
- Disconnect the deep fryer (switch in position « 0 »)
- Leave the deep fryer to cool down (to accelerate cooling, lift the heating element and rest
  it on the edge of the pan). Until the probe of the thermostat fixed to the heating element
  cools down, you cannot reset the safety thermostat
- Push the red button hard (you will hear a « click » when it engages)

5.4 Safety switch
As soon as the heating element is lifted more than 5 mm, the safety switch is actuated and
cuts off the power.

    Check that the heating element box is resting properly on the edge of the tank.




                                                                Fig. 6




Date de création: 13.11.95 par:LIE               Date de modif.: 16.08.96          Fichier DATA WORD IN

                      Fabrique SA                Doc. No.:          IN-F94EA       Page No.:   10 / 13
5.5 Spare parts
Only use original spare parts. When ordering spare parts, please quote the following in addition to the number
from the list below :
                                                              type of deep fryer                         Type
You will find this information on page No 1 of this           serial number                              No
manual.                                                       voltage, current and rating                U, I, P

Description         (LPGEN-01 \LP F94)            P1 P1 P2 C C M Item No                 Drwg            Feature      Man'r
                                                  94 94 94 94 94 94                      code
                                                     T        T
Pilot lamp E10 + clear lens + metal nut           1   1   2    1   1      1 3269+3270 H1,H4             250 V, 2 W    Valentine
(Lamp for switch) (no bulb)                                                 +3273
Pilot lamp E10 + yellow lens + metal nut          1   1   2    1   1      1 3269+3271 H2,H5             250 V, 2 W    Valentine
(Lamp for thermostat) (no bulb)                                             +3273
Pilot lamp E10 + green lens + metal nut           1   1   2    1   1      1 3269+3272 H3,H6             250 V, 2 W    Valentine
(Lamp for dialogue)    (no bulb)                                            +3273
Bulb E10 220/240V                                 3   3   6    3   3      3 0739                                      ERG
Positive safety thermostat probe ø4 mm            1   1   2    2   2      3 0705-02      S1,S2,S3     20 (4) A 400 V~ EGO

Safety switch XTD 22                              1   1   2    2   2      3 3278         S10,S11,     16 (4) A 400 V~ SAIA
                                                                                         S12
Main thermostat casing 46x50 probe 6x90/130       1   1   2    1   1      1 3201-02      S20,S21       16 (4) 400 V   EGO

Contactor 3 x 20 A                                             2   2        3252         K1,K2           3 x 20 A     TELEMECANIQUE
Contactor 3 x 25 A                                                        2 3251         K1,K2           3 x 25 A     TELEMECANIQUE
Switch 3P 46x46 4x10A screw connection            1       2    1          1 0719         S30,S31        10A, 400V     EGO
Main switch large 60x65 screw connection              1            1        0718         S30,S31        25A, 400V     EGO
Main connector nylon 20EDS                        1   1   1    1   1      1 3262         XT1             16 mm2       AWAG
Connector nylon 10E                               3   3   3    3   3      3 3257         XT10,XT11,       4 mm2       AWAG
                                                                                         XT12
Carbon resistor                                   1   1   2                 0742         R20,R21        120K, 2W      Philips


Sundry
Timer + button                                                              3190+0712-02
Button for thermostat, switch, timer                                        0712-02
Adjusting key for thermostat                                                0715
Cable for heating element 4 x 1,5 length 1.05 m                             3297-01
Oil cock : block with 2 springs                                             0663
           sliding part                                                     0665
           rod                                                              3172
           handle                                                           0670


Complete heating element set
Rectangular heating element 170x310 mm with junction box, thermostat, safety switch, cable 4x1,5 length 1.05 m

3x400V 7 kW                                       1       2    2          3 3101-02      R1.2,3+S1+S10, R4.5,6+S2+S11, R7,8,9+S3+S12
3x400V 11 kW (Turbo)                                  1            2        3105-02      R1.2,3+S1+S10, R4.5,6+S2+S11, R7,8,9+S3+S12



Baskets, filter
Basket P1-94 large             200x279x H120 mm   1   1                     3179
Basket P2 +C-94 small          160x268x H120 mm           2    2   2        3180
Basket C-94 large              358x273x H130 mm                1   1        3182
Basket M-94 small              255x268x H120mm                            2 3181
Basket M-94 large              545x273x H130 mm                           1 3183
Metal filter P-94 + NDU 200                       1   1   1                 3176
Metal filter C-94                                              1   1        0662
Metal filter C-94 pump + C-94                                             1 3376-01
Microfilter + telescopic support                                            8815         Option
Spare filter for microfilter                                                8823         Option


5.6 Wiring diagram

Date de création: 13.11.95 par:LIE                            Date de modif.: 16.08.96                        Fichier DATA WORD IN

                          Fabrique SA                         Doc. No.:            IN-F94EA                   Page No.:   11 / 13
                        Le thermostat de travail enclenche et déclenche en 2 cascades
                        Pin 11 du thermostat de travail = barre supérieure du corps de chauffe



                        Arbeitsthermostat schaltet in 2 Stufen
                        Kontakt 11 des Arbeitsthermostats = oberste Heizschlange


                        Mainthermostat cuts in 2 steps
                        Mainthermostat-contact 11 = uppest heating bar




Date de création: 13.11.95 par:LIE                  Date de modif.: 16.08.96            Fichier DATA WORD IN

                      Fabrique SA                   Doc. No.:          IN-F94EA         Page No.:   12 / 13
5.7 Layout




Date de création: 13.11.95 par:LIE   Date de modif.: 16.08.96      Fichier DATA WORD IN

                      Fabrique SA    Doc. No.:          IN-F94EA   Page No.:   13 / 13

				
DOCUMENT INFO
Shared By:
Categories:
Stats:
views:448
posted:3/22/2011
language:English
pages:13