Documents
Resources
Learning Center
Upload
Plans & pricing Sign in
Sign Out

Abb Fig

VIEWS: 18 PAGES: 2

									Montageanleitung MANET Schiebetür                     Mounting instructions for MANET sliding door
Variante III - COMPACT                                Variant III - COMPACT
Schiebetüranlage an Wand / an Glas                    Sliding door fixed to wall / fixed to glass
                                                                                                                   Ansichtseite: innen
                                                                                                                   View from inside
Benötigte Werkzeuge:                                  Necessary tools for mounting:
                                                                                                                                            3           3                         3
Inbusschlüssel SW 4                                   4 mm A/F Allan key                                            1
Inbusschlüssel SW 5                                   5 mm A/F Allan key
Kreuzschlitzschraubendreher (mittlere Größe)          Cross-head screwdriver (medium-size)
Hakenschlüssel Art.-Nr.: 21.138 (nur bei Montage      Hook wrench Art. No.: 21.138 (only required for
an Glas)                                              fixing to glass)                                                                      4                  2             3           1

Schraubenempfehlung bei Montage an Wand:              Recommended fixings for wall installation:
(Nach Wandbeschaffenheit und Dübelart bauseits)       (Depending on type and condition of wall and anchor /
Senkschraube M6 x Länge-A2/A4 bzw.                    wall plug components provided by others)
Senkholzschraube Ø 6 x Länge-A2/A4                    Countersunk screw M6 x length-A2/A4 or countersunk
                                                      wood screw Ø 6 mm x length-A2/A4
                                                                                                                                   Schiebetür
                                                                                                                                   Sliding door
Schritt 1:                                            Step 1:
Montage an Wand:                                      Fixing to wall:
Klemmhalter (3) nach Maßplanung an Wand an-           Mark position of clamp mounting (3) on wall as per
zeichnen, Dübellöcher mit Dübeln einbringen und       dimensioned diagram. Drill anchor holes and provide
Klemmhalter (3) verschrauben.                         anchors/wall plugs. Secure clamp mounting (3).

Montage an Glas:                                      Fixing to glass:
Klemmhalter (3.8) mit Punkthalter, bestehend aus      Secure clamp mounting (3.8) with single-point fixing
Klemmscheibe (3.9), Klemmring (3.1), Kegelhülse       comprising clamping washer (3.9), clamping collar
(3.2) mit Gewindeeinsatz und Schraube (3.3) am        (3.1), tapered bush (3.2) with threaded insert and
Glas verschrauben (Inbusschlüssel SW = 4 mm und       screw fastener (3.3) to glass (using 4 mm Allan key
Hakenschlüssel Art.-Nr. 21.138 / max. 15 Nm).         and hook wrench Art. No. 21.138 / max. tightening
Abschließend den Deckel (3.4) in die Kegelhülse       torque 15 Nm).                                                                                              5
einclipsen.                                           Then clip cover (3.4) into tapered bush.                                                                         Abb./Fig. A


Schritt 2:                                            Step 2:
Die Klemmhalterbacke (3.6) mit dem Aushebeschutz      Pre-assemble the clamp mounting jaw (3.6) with anti-
(3.5) mittels der Schraube (3.7) vormontieren.        lift device (3.5) using screw (3.7).
Klemmhalterbacke (3.6) hierbei lose nach unten hän-   Allow the clamp mounting jaw (3.6) to hang down                                                                       3.2
                                                                                                                         2                                    3.1
gen lassen. Laufrohr (2) einlegen, Klemmhalterbacke   loose. Insert tubular track rail (2), rotate clamp                                                                          3.4
(3.6) wieder nach oben drehen und Klemmhalter (3)     mounting jaw (3.6) up again and secure clamp
positionsrichtig endmontieren.                        mounting (3) in the correct position.

Schritt 3:                                            Step 3:                                                                     3.3
Türstopper (1) links und rechts auf Laufrohr (2)      Position door stops (1) for the left and right on the
vorfixieren, damit die Tür bei weiterer Montage        tubular track rail (2), pre-fix to ensure that the door
nicht von Laufrohr (2) rollen kann. (Inbusschlüssel   is unable to slip from the tubular track tube (2) as
SW = 4 mm).                                           installation proceeds. (Use 4 mm Allan key).
                                                                                                                                                                      3.9
Schritt 4:                                            Step 4:                                                           3.7                       3.5
Glas unterhalb Laufrohr (2) auf geeignete Unterlage   Position the glass on a suitable support below the tubular                     3.6
stellen. (Bodenluft 7 - 8 mm).                        track rail (2). Leave a gap to the floor of 7 to 8 mm.
                                                                                                                                                        3.8


DORMA-Glas                                                           800.52.147.6.32                                         Stand/Issue 06/04                                              Seite/Page 1/2
Schritt 5:                                               Step 5:
Schraubbolzen (4.1) durch Bohrungen des Rollenwa-        Insert stud screws (4.1) through the bores of the
gens (4) führen und Anlageringe (4.2) aufstecken.        carrier (4) and fit locating collars (4.2).


Schritt 6:                                               Step 6:                                                             4
Rollenwagen auf Laufrohr (2) aufsetzen und Anla-         Place the carrier on to the tubular track rail (2) and
                                                                                                                                                                           2
geringe mit den Glasbohrungen (4.2) in eine Flucht       bring the locating collars in line with the glass bores
bringen. Rollenwagen mittels Klemmring (4.3), Kegel-     (4.2). Secure the carrier to the glass by means of
hülse (4.4) und Schraube (4.5) (Inbusschlüssel SW =      clamping collar (4.3), tapered bush (4.4) and screw                         4.1
5 mm) am Glas verschrauben (max. 15 Nm). Mit dem         (4.5) using 5 mm Allan key (max. 15 Nm).                                                                                           4.7
Rollenwagenwerkzeug (4.7) die Schraubbolzen (4.1)        To tighten, counterhold the stud screws (4.1) using                                                         4.3
                                                                                                                     4.2
gegenhalten.                                             the carrier tool (4.7).                                                                               4.4
Abschließend die Deckel (4.6) in die Kegelhülsen
(4.4) einclipsen.                                                                                                                                        4.5


Schritt 7:                                               Step 7:
                                                                                                                       5.1                     4.6
Zunächst Bodenführung (5) durch Drehen des Einsat-       First adjust the floor guide (5) to the correct glass
zes (5.1) auf die richtige Glasblattdicke einstellen.    thickness by rotating the insert (5.1).
Bodenführung (5) an Anfangsposition der Schiebetür       Secure the floor guide (5) to the floor at the start
(in Schieberichtung) lotrecht unter dem Laufrohr         position of the sliding door (as seen in sliding
(2)/(Abb. A) mit den beigestellten Befestigungsmit-      direction) plumb below the tubular track rail (2)/(Fig.A)
teln auf den Fußboden schrauben (Kreuzschlitz-           with the fixings provided (using cross-head screwdriver                  5
schraubendreher mittlere Größe).                         of medium size).


Schritt 8:                                               Step 8:
Türstopper (1)/(Abb. A) links und rechts an Laufrohr     Secure door stops (1)/(Fig. A) left and right on the
(2)/(Abb. A) so endfixieren (Inbusschlüssel SW = 4 mm),   tubular track rail (2)/(Fig. A) using 4 mm Allan key
dass die Schiebetür immer in der Bodenführung (5)        so that the sliding door remains located in the floor
läuft. Korrekten Lauf der Schiebetür überprüfen.         guide (5) at all positions. Check that the sliding door
                                                         operates correctly.




DORMA-Glas                                                              800.52.147.6.32                                              Stand/Issue 06/04                         Seite/Page 2/2

								
To top