Documents
Resources
Learning Center
Upload
Plans & pricing Sign in
Sign Out

Informal

VIEWS: 8 PAGES: 2

									ZAP03BE-230/400 Volt 4 Wire 5 Amp and 110 Volt
3 Wire 5 Amp are part of the new range of Watt/VA
Demand British Standard meters from Zaptronix.
 Designed specifically to meet the sophisticated
requirements of utilities.
                                                               Informal
A multitude of NEW features include:
   All the standard features are detailed on the flip side
   Event Logging
   Data Logging - per phase and input pulses                   Residential
   Flexible Time Of Use (TOU)
   Configurable I/O (4 outputs, 2 inputs)
   Isolated aux. Power supply for external interface devices
   OFGEM (UK) & COP certified
   IEC 61036, 61268
                                                               Commercial
   SABS 0142 certified & SABS Mark Approval
   MODBUS, Stark & MV90 compliant (pending)
   In field upgradable firmware
   Documentation, technical manual and user friendly
   software available on CD or from the internet:              Industrial
   www.zaptronix.co.za
Specifications
Electrical                                            Programmable features
3 Phase, 4 Wire, 230/400V, 5A &                       CT/VT ratio             : 25000 max., Compensation factor
3 Phase 3 Wire, 110V 5A IEC61036, 61268               Decimal point           : 0 to 3 & auto-ranging
Accuracy              : 1-5/6 Class 1, 2 resp.        Various display settings and sequences
Protection Class      : 2                             Demand                  : Thermal, Block, Sliding window - 2 to
Voltage range         : (230V) 184 to 275V ph-ntl                                5,10,15,20,30,60 (1 & 20 SW)
                        (110V) 88 to 132V ph-ph       Demand synch            : RTC (Line or Internal)orExternal
Frequency Range       : 40 to 60 Hz                   I/O configuration       : See below under I/O
Burden (phase)        : V 1.0W/2.0VA                  Password protection : 3levels
                         I 1.0VA                      Day Light Saving (DST)
Operating temp.       : -10 to 45°C                   Time of Use             : 4rates (2 banks), 96 daily switching
Calibration LEDs      : 5 pulses/Wh & VArh                                       cycles, 8 day types, 4 seasons, 24
NOTE:                                                                            holidays, 2 schedules,
S2 linked internally to neutral                       Data Logging            : per phase & inputs Watts in/out, Var
230V: Terminals 3, 6, 9, 11 linked                                               import/export, status tags. Maximum 4
110V: Terminals 3, 9, 5 linked                                                   channels, 4ch/30mininterval - 250 days
                                                      Power fail indicator : per phase
Diagnostics
Constant Self-Diagnostics displaying specific error   I/O interfacing
codes, includingPhaseLoss & Tamper indication         Maximum rating: 30Vdc 10mA
On-site installation check - Reverse polarity         10wayconnector inside terminal cover
                           - Cross wiring             O/p: energy pulses, EOI, integration period, MD reset
                                                      I/p: MD sync., EOI, water, gas pulses (programmable with
Communications                                        multiplier)
•   IEC61107Infra-red, serial & MODBUS                Standard 4 outputs, 2 inputs OR
•   Serial port/RS232 allowing modemhandshaking       Serial interface plus 3 outputs, 1 input OR
•   Daisy chaining via RS485 interface adapter        Modem interface plus 2 outputs
•   Remote communication via adapter for              Auxiliary supply - 6kVisolation, 5VDC, max. 100mA
     • Radio network Paknet (Fastnet)
     • GSM modem                                      Standard Features
     • PSTN (fixed telephone line)                    •Compact design: 110 x 120 x 75mm
                                                      •Manufactured under EN ISO9002
Display                                               •Accuracy,exceeds 0.5% Active & 1.0% Reactive
Large 8 digit LCD display incl. user friendly icons   •Display per phase - consumption & instantaneous demand
Digit size             : 9.0 x 4.5 mm                 •Four Quadrant metering, Engineeringvalues, Error Codes
Temp. rating           : -30 to 85°C                  •Optional protected upgradeable firmware
Life time              : >10 years
Mechanical                                            64
                                                                                                                0V
                                                                                                               +5V
                                                                                                                               GND1
                                                                                                                               5V100maMAX
                                                                                                                               GND2
Terminal Ø           : 4.5 mm                                                                                       C3
                                                            29                                                                 OUTPUT2
Footprint            : BS5685                                                                                       E3
                                                                                                                    C4         OUTPUT1
Terminal cover       : transparent                                           36
                                                                                                                                                       10
Weight               : 585 g                                                            120
                                                                                                                    E4
                                                                             FrontView                              C2
                                                                                                                               GND3
Meter may be DIN rail mounted                                                                                                  OUTPUT3
                                                                                                                    E2
Standard Registers                                                            20
                                                                                        80
                                                                                                                    A1         INPUT2                   1

Energy/Demand          : Per phase - Watts, VAr, VA        110                                      29
                                                                                                                    K1
                                                                                                                    A1         INPUT1
                                                                                   45
Frozen Billing Data    : Present plus 14 historical                                                                 K1
Event Logging          : Power up/Fail, MD. reset,               35                                                 C1         OUTPUT4

                         RTC fail, Battery fail,                                   Top View                         E1

                         Pwr. ON duration, Errors                                                            NOTE: SOMEGROUNDSARECOMMON


Engineering Data       : Volts, Amps, Frequency, PF                                                          T erminal       I/O                I/O T erminal
Miscellaneous Data     : Date, Time, F/W & H/W                                                                    1      O/P 4              O/P 1        6
                                                                                                                  2      I/P 1              O/P 2        7
                         Rev, CT/VT, Ratio, # of                                                                  3      I/P 2              G nd 2       8
                                                                               SideView
                         resets, Cal. Constants, SN    ElectricalConnectionDiagram                                4      O/P 3              O/P 3        4

                         ofInterrogation device                           1 2 3 4 5 6 7 8 9 11                    5
                                                                                                                  6
                                                                                                                         Gnd 3
                                                                                                                         O/P 1
                                                                                                                                            O/P 4
                                                                                                                                              I/P 1
                                                                                                                                                         1
                                                                                                                                                         2
Error Logging          : Missing & Phase Sequence                                                                 7      O/P 2                I/P 2      3
Default data           : Backup data under fault                      K       L K             LK         L        8      Gnd 2              G nd 3       5
                                                                      K       L K             L K        L
                                                                                                                  9      +5V                   +5V       9
                         Conditions
                                                       L1
                                                       L2
                                                       L3
                                                       N                                                         10      Gnd 1              G nd 1      10

								
To top