AQUA-GARD by gjjur4356

VIEWS: 24 PAGES: 2

									                                                                                                    AQUA-GARDTM


DESCRIPTION      Sansin Aqua GuardTM is a clear, water protection product for new and existing above ground
concrete and masonry substrates. Unlike regular sealers Sansin Aqua-Guard™ penetrates and bonds to the
substrate, allowing it to breath while protecting the concrete and masonry from water and contaminants entering
the substrate.



                                                                         PACKAGING
APPLICATIONS                                                             Available in 1US gallon containers
    •   Brick and Stucco Walls
    •   Concrete block buildings
    •   Concrete Structures, Roof tiles                                  COVERAGE
    •   Concrete Slabs and sills, etc.                                       •   Full saturation should be achieved.
                                                                             •   Will cover approximately 40-200sq.ft. per
                                                                                 gallon dependant on porosity of the
PRODUCT BENEFITS                                                                 substrate.
    •   Clear, will not discolor
    •   Can be custom tinted
                                                                         PREPARATION
    •   Odorless
    •   Penetrates deep into the substrate                                   •   Test Area: Pretest a hidden area. Check if
                                                                                 surface has been pretreated. Appearance
    •   Prevents freeze-thaw damage
                                                                                 of a white residue after drying indicates a
    •   Reduces efflorescence, splitting & cracking
                                                                                 pretreated surface.
    •   Protects reinforcing steel from erosion
    •   Reduces dusting
    •   Breathable                                                       WORKING PROCEDURE
    •   Keeps the substrate cleaner                                          •   Apply by sprayer, brush or roller
                                                                             •   Do not dilute
                                                                             •   Do not apply in heat of day or direct sunlight
CHARACTERISTICS
                                                                             •   One coat application
                                                                             •   Can be applied at any temperature above
    •   Coloring ...................................................
                                                                                 freezing (ideal temperature between 15-
    •   Odor ........................................................
                                                                                 20˚C)
    •   Form .............................................. Liquid
                                                                             •   Clean surface before application
    •   Specific Gravity (g/cm3)
                                                                             •   Apply liberally until the surface is saturated,
    •   Density (lbs/gall)
                                                                                 do not allow to puddle.
    •   pH,...........................................................
                                                                             •   DO     NOT      SPILL      ON     ALUMINIUM
    •   Viscosity, @Zahn 4 @21°C ....................                            WINDOWS ETC.
    •   Solvents...................................................          •   Allow 28 days for new concrete to cure
    •   Freezing Point .........................................                 before treatment.
    •   Diluent .....................................................        •   See Directions For Use
    •   Cleanup ...................................................
    •   Drying Time (To touch) @ 20ºC (68ºF)...
        ...................................Do not allow to dry           STORAGE
    •   Coverage(Depending on coating                                        •   Close container lightly
        appearance and thickness) .....................                      •   Store in cool dry
        ................................. 100-200 sqft/ Usgal                •   Avoid exposure to sunlight
    •   Shelf life…………………………Looses                                           •   Do not reuse container
        strength slowly over time                                            •   Do not allow freezing
    •   VOC(g/l) ...........................................0 g/l            •   Rinse container thoroughly before disposal




                                                                                                            Aqua Gard Page 1 of 2
                                                      or implied, are made as to the result to be obtained
SAFETY See Material Safety Data Sheet                 if not used in accordance with the published
                                                      Directions for Use. The Sansin Corporation does
                                                      not assume any legal responsibility for use or
WARNING TO USERS                                      reliance on same. This information must on no
                                                      account be used as a substitute for necessary field
Do not use metal containers.                          tests, which alone can ensure that the product is
                                                      suitable for the expected use. Before using any
The information contained in this document is given   product, read its label.
in good faith based on our current knowledge. The
use of the product is beyond the control of The
Sansin Corporation, and no guarantees, expressed


                                                                                         September 2009




                                                                                       Aqua Gard Page 2 of 2

								
To top