									Montageanleitung
Assembly Instructions
LVP-25-Z20-5-CA
MICRO-EPSILON MESSTECHNIK
GmbH & Co. KG
Königbacher Strasse 15
D-94496 Ortenburg
Tel. +49/85 42/1 68-0
Fax +49/85 42/1 68-90
e-mail: info@micro-epsilon.de
www.micro-epsilon.de
Zertifiziert nach DIN EN ISO 9001: 2008
Certified acc. to DIN EN ISO 9001: 2008
                                                                                           Inhalt

            1.    Einführung .................................................................................................................................. 5

            2.    Technische Daten ....................................................................................................................... 6

            3.    DIP-Schalter ................................................................................................................................ 7




                                                                                                                                                                                             Deutsch
            3.1   Einstellen der DIP-Schalter ................................................................................................................................ 7
            3.2   DIP - Schalterstellung für Zugstangenanschluss .............................................................................................. 8

            4.    Spannungsversorgung, Sensor und Signalausgabe ............................................................... 9
            4.1   Verdrahtung........................................................................................................................................................ 9
            4.2   Versorgung und Signal ...................................................................................................................................... 9
            4.3   Sensor .............................................................................................................................................................. 10
            4.4   Signalverhalten, Anschluss .............................................................................................................................. 11

            5.    Kalibrierung des Messsystems ............................................................................................... 12

            6.    Anforderungen an das Messobjekt ......................................................................................... 13




LVP-25-Z20-5-CA
LVP-25-Z20-5-CA
Einführung

                  1.      Einführung
                  Die vorliegende Montageanleitung beschreibt die Inbetriebnahme des Spannhubsensors LVP-25-Z20-5-CA
                  mit der analogen Auswerteelektronik MSC7210-U (Spannungsausgang 2 ... 10 VDC) beziehungsweise
                  MSC7210-I (Stromausgang 4 ... 20 mA).

                  i    Weitere Informationen finden Sie in der Betriebsanleitung der Serie „induSENSOR LDR“.

                                                  5,8




                                                                                                                                Deutsch
                                                                                              3-pol. Anschlusskabel
                                          90°
                                                                                              mit Abschirmung
                                             4                                                ø1,8 mm / AWG 28




                                                           45°
                               ø19,85
                                ø18




                                0,3x45°                                  0,3x45°                    ø13
                                                          38
                                    5                                                                     5,5
                                          ø11,5




                                                                                                 ø11,5
                                                                                ø10
                                                                 ø8


                                                                      Messhülse
                                                        Welle ø8 und ø10, (ferromagnetisch)
                                                        nicht im Lieferumfang enthalten

                  Abb. 1: Maßzeichnung LVP-25-Z20-5-CA, Maße in mm, nicht maßstabsgetreu

LVP-25-Z20-5-CA                                                                                                       Seite 5
Technische Daten

                   2.       Technische Daten
                   Modell                        LVP-25-Z20-5-CA-AC
                   Artikel-Nr.                   2617008
                   Messprinzip                   LVP
                   Messbereich                   25 mm
                   Target (Im Lieferumfang)      Art.-Nr. 0482218 für Wellendurchmesser 8 mm
                                                 Art.-Nr. 0482219 für Wellendurchmesser 10 mm
                   Auflösung                     0,01 mm
                   Linearität                    typisch ±1 % d.M. (0,25 mm)
                   Dynamik                       150 Hz (-3 dB)
                   Sensorgehäuse                 Edelstahl
                   Temperaturstabilität Sensor   < ±0,01 % d.M, / °C
                   Temperaturbereich Sensor      -40 °C ... +150 °C
                   Schutzart Sensor              IP 67
                   Medium                        Luft, Öl
                   Elektronik                    Serie MSC7210
                   d.M. = des Messbereichs




LVP-25-Z20-5-CA                                                                                 Seite 6
DIP-Schalter

                  3.                       DIP-Schalter
                  3.1                      Einstellen der DIP-Schalter
                  Vor Anschluss des Spannhubsensors LVP-25-Z20-5-CA an die Auswerteelektronik müssen Sie die DIP-Schal-
                  ter auf der MSC7210 korrekt einstellen.

                  i    Der Spannhubsensor kann mit Zugstangenanschlüssen ø8 beziehungsweise ø10 betrieben werden!

                       Führen Sie für den Zugstangenanschluss ø8 und ø10 den unter Kap. 2.2 beschriebenen Einstellvor-




                                                                                                                                                                                                                               Deutsch
                       gang durch.
                  Die ordnungsgemäße Funktion des Sensors ist nur bei korrekter Einstellung der DIP-Schalter gewährleistet.

                  i    Andernfalls sind Abweichungen zu den technischen Daten des Systems (zum Beispiel Linearität, Tem-
                       peraturstabilität) möglich!
                            Beachten Sie beim Einstellvorgang die Wertigkeit des jeweiligen DIP - Schalters (2-1, bzw. 4-3-2-1)
                            sowie die Schalterstellung.
                  In Abb. 2 ist ersichtlich auf welcher Seite sich die Schalterstellung „ON“ befindet.

                  SCREW-PAD-3
                                                                                                           2 1
                                                                                                     J1
                  X4                       GND                          Ub

                                                                                                                  GAIN
                                           IN                           FB-
                                  Top
                            R4




                                           R                             Q                                  ON
                                           RC                          FB+                     R53
                       FREQUENZ            Out                           Q
                                                                                               Top
                             ON
                       1




                                                                                                           2 1                        4 3 2 1
                                                                                                     J3




                                                                                                                              J2




                                                                                                                                                      PHASE
                                                                                                                       TEST
                       2
                       3




                                                                                                            ON                                  ON
                                                J6        J5      J7
                       4




                       J4

                                                                                          R2         20k
                                                                                                 3
                                                                                          1           3
                                                                  Output




                                                                                                                              Prim+
                                                                           Shield




                                                                                                              Shield
                                        Power




                                                                                                                                               Sec+
                                                           Ognd




                                                                                     R1
                                                 Pgnd




                                                                                                                                       Prim-




                                                                                                 3
                                  X1                                                10k                     X2
                                                                                                                                                                   SCREW-PAD-3




                                                        Riacon 07                         1           3                       Riacon 07
                                                                                                 3                                                            X4

                                                                                          1            3
                                                                                          R3         20k

                                                                                                                                                                                 Abb. 2: Sensor Controller MSC7210
                                   RIA07-05                                                                  RIA07-04




LVP-25-Z20-5-CA                                                                                                                                                                                                      Seite 7
DIP-Schalter

                  3.2             DIP - Schalterstellung für Zugstangenanschluss

                   Frequenz
                                                                                   DIP - Schalterstellung für    DIP - Schalterstellung für
                                                            J2                     Zugstangenanschluss ø8       Zugstangenanschluss ø10




                             ON
                   4 3 2 1
                                                                 4 3 2 1
                                                                                     Schalter J2 (Phase)           Schalter J2 (Phase)




                                                                           PHASE
                                                                      ON
                                                                                        1            OFF             1            ON
                             J4
                                                                                        2            OFF             2            OFF
                                                                                        3            ON              3            OFF

                  Abb. 3: Verstärkerelektronik, DIP - Schalter für                      4            OFF             4            ON
                  Phase (J2) und Frequenz (J4)                                      Schalter J4 (Frequenz)       Schalter J4 (Frequenz)
                                                                                        1            OFF             1            OFF
                                                                                        2            ON              2            OFF
                                                                                        3            ON              3            ON
                                                                                        4            OFF             4            OFF

                                                     Gain                          DIP - Schalterstellung für    DIP - Schalterstellung für
                                                   J1 2 1                          Zugstangenanschluss ø8       Zugstangenanschluss ø10

                                                       ON
                                                                                      Schalter J1 (Gain)            Schalter J1 (Gain)
                                                     Test                               1            ON              1            ON
                                                   J3 2 1
                                                                                        2            OFF             2            OFF
                                                       ON
                                                                                       Schalter J3 (Test)           Schalter J3 (Test)

                  Abb. 4: Verstärkerelektronik, DIP - Schalter für                      1            OFF             1            OFF
                  Gain (J1) und Test (J3)                                               2            ON              2            ON


LVP-25-Z20-5-CA                                                                                                                          Seite 8
Spannungsversorgung, Sensor und Signalausgabe

                     4.           Spannungsversorgung, Sensor und Signalausgabe
                     Der minimale Biegeradius des Versorgungs- und Ausgangskabels PC710-6/4 (erhältlich als Zubehör) be-
                     trägt 24 mm. Alle Anschlüsse für Spannungsversorgung / Sensoren / Signalausgabe befinden sich auf der
                     Elektronik (siehe Abb. 5).
                     Kabeleigenschaften: Außendurchmesser Kabel: 3,0 ... 5,0 mm
                                              Anschlussdraht:                0,08 ... 0,25 mm 2
                     4.1          Verdrahtung




                                                                                                                                          Deutsch
                     Für den Anschluss der Sensoren und für die Verdrahtung des Ausgangs- und Versorgungskabels muss das
                     Gehäuse geöffnet werden.
                            Lösen Sie die Schrauben.
                            Führen Sie das nach Kap. 3.3 konfektionierte Sensorkabel durch die Kabelverschraubung
                            Isolieren Sie die Anschlusslitzen des Ausgangs- und Versorgungskabels ab. Montieren Sie passende
                            Aderendhülsen auf die Litzen und die Schirmung; verwenden Sie dazu eine geeignete Quetschzange.
                            Führen Sie das Ausgangs- und Versorgungskabel durch die vorgesehene Kabelverschraubung.
                            Verdrahten Sie die Anschlusslitzen im Controller.
                            Setzen Sie den Controller zusammen und ziehen Sie die Schrauben fest.
                     4.2          Versorgung und Signal

                                                                    Schraubklemme X1 Funktion
                                                                    Power                    Versorgungsspannung 18 ... 30 VDC
                                                                    Pgnd                     Masse (0 V)
                         Schirmung
                             Signal                                 Ognd                     Signal-Masse (0 V)
                      Signal-Masse
                             Masse                                                           MSC7210-U: Signal (2 ... 10 VDC)
                        Versorgung                                  Output
                                                                                             MSC7210-I: Signal (4 ... 20 mA)
                                                                    Shield                   Schirm Versorgungskabel
                     Abb. 5: Anschlussbelegung für Versorgung und Signal, Klemmleiste X1
LVP-25-Z20-5-CA                                                                                                                 Seite 9
Spannungsversorgung, Sensor und Signalausgabe


                     i     Verwenden Sie ausschließlich geschirmte Leitungen!

                     Für den Betrieb mehrerer Controller ist zu beachten:
                      - Die Schirme der Ausgangs-/Versorgungskabel müssen potentialfrei sein.
                      - Die Schirme der Ausgangs-/Versorgungskabel dürfen nicht elektrisch leitfähig miteinander verbunden
                        sein.
                      - Die Controllergehäuse dürfen nicht elektrisch leitfähig miteinander verbunden sein.
                     4.3       Sensor

                     Elektronikseitige Konfektionierung des Sensorkabels
                           Entfernen Sie den Kabelmantel des Sensorkabels auf einer Länge von circa 50 mm. Beschädigen Sie
                           nicht das Schirmgeflecht.
                           Verdrillen Sie das Schirmgeflecht leicht.
                           Schieben und schrumpfen Sie den 40 mm langen Schrumpfschlauch (Art.-Nr. 0181001) über das
                           Schirmgeflecht.
                           Isolieren Sie die 3 Litzen 6 mm weit ab und verzinnen Sie sie.
                           Schieben und schrumpfen Sie den 25 mm langen Schrumpfschlauch (Art.-Nr. 0182003) auf das Kabel.
                           Positionieren Sie den Schrumpfschlauch so, dass er die Anschlusslitzen 5 mm weit bedeckt.
                           Crimpen Sie die Aderendhülse (Art. Nr. 0325048) auf das freie Ende des Schirmgeflechts.




                                                                              Abb. 6: Fertiges Sensorkabel

LVP-25-Z20-5-CA                                                                                                        Seite 10
Spannungsversorgung, Sensor und Signalausgabe

                     4.4      Signalverhalten, Anschluss

                     Das Ausgangssignal steigt, wenn der Stößel eingeschoben wird. Wird die umgekehrte Wirkrichtung benö-
                     tigt (das heißt das Signal wird kleiner, wenn der Stößel eingeschoben wird), sind die Anschlüsse prim+ und
                     prim- zu tauschen.
                     Für die Einhaltung der EMV-Richtlinie darf ein selbstkonfektioniertes Sensorkabel nicht länger als 10 m
                     sein.
                                                                  Schraubklemme X2         Farbe der Litze (Sensorkabel)




                                                                                                                                      Deutsch
                                                                   Shield                Schirm Sensorkabel
                                                                   prim+                 braun
                                                       Schirmung   prim-                 weiß
                                                       Prim +
                                                       Prim -      sec+                  grün
                                                       sec +




                      Abb. 7: Anschlussbelegung für Sensor, Klemmleiste X2

                      i    An den Schirm des Sensorkabels ist eine weiße Aderendhülse angeschlossen.




LVP-25-Z20-5-CA                                                                                                            Seite 11
Kalibrierung des Messsystems

                      5.       Kalibrierung des Messsystems

                                                                                                -12,5     0 +12,5




                                                   Zugstange mit Targetring                             Sensor

                      Abb. 8: Kalibrierung Messsystem LVP-25-Z20-5-CA

                      1. Notieren Sie den Messwert wenn sich das Messobjekt (Zugstange mit Targetring) völlig ausserhalb des
                         Sensors befindet -> Offsetwert des Sensors.
                      2. Bewegen Sie nun das Messobjekt in den Sensor bis der Messwert mit dem unter 1. ermittelten Offset-
                         wert übereinstimmt -> elektrischer Nullpunkt des Sensors.
                      3. Bewegen Sie nun das Messobjekt vom elektrischen Nullpunkt des Sensors aus um -12,5 mm an den
                         Messbereichsanfang des Sensors (s. Abb. 8).
                      4. Stellen Sie mit dem Trimmer R1 (s. Abb. 2) den Messwert auf 2 VDC (MSC7210-U) bzw. 4 mA
                         (MSC7210-I) ein.
                      5. Bewegen Sie nun das Messobjekt an das Messbereichsende des Sensors (in Abb. 8: Pos. +12,5 mm).
                      6. Stellen Sie nun mit dem Trimmer R3 (s. Abb. 2) den Messwert auf 10 Vdc (MSC7210-U) bzw. 20 mA
                         (MSC7210-I) ein.
                      7. Die Schritte 3 - 6 solange wiederholen bis die gewünschte Kalibriergenauigkeit erreicht ist.
                      Das Messsystem ist kalibriert wenn das Messsignal an der Pos. -12,5 mm = 2,0 Vdc (4 mA) und an der
                      Pos. +12,5 mm = 10 Vdc (20 mA) beträgt.

                      i    Wird die umgekehrte Wirkrichtung des Messsignals benötigt, d. h. sinkt das Messsignal bei Bewegen
                           des Messobjekts in Richtung Position +12,5 mm, so sind die Anschlüsse prim+ und prim- an der
                           Schraubklemme X2 einfach zu tauschen!



LVP-25-Z20-5-CA                                                                                                        Seite 12
Anforderungen an das Messobjekt

                      6.      Anforderungen an das Messobjekt
                      Das Messobjekt besteht aus dem kundenspezifischen Zugstangenanschluss (ø8 beziehungsweise ø10)
                      sowie den werkseitig mitgelieferten Aluringen (ø8 beziehungsweise ø10). Es empfiehlt sich, den benötigten
                      Aluring auf den Zugstangenanschluss aufzukleben (zum Beispiel mit „LOCTITE 2701“).
                      Zur Einhaltung der spezifizierten technischen Daten sind an den Zugstangenanschluss folgende Anforde-
                      rungen zu stellen:
                       - Der Werkstoff des Zugstangenanschlusses muss gute ferromagnetische Eigenschaften aufweisen. Ein




                                                                                                                                     Deutsch
                         Werkstoff mit nur schwachen ferromagnetischen Eigenschaften wie zum Beispiel Hartmetall ist für die
                         Messung nicht geeignet. Das im Lieferumfang enthaltene Testprotokoll wurde mit einem Zugstangenan-
                         schluss D8 mit der Werkstoff-Nr. 1.8519.05 aufgenommen.

                      i    Die technischen Daten Linearität beziehungsweise Temperaturstabilität des Systems können von dem
                           Werkstoff der eingesetzten Zugstange beeinflusst werden.
                       - In der Position Messbereichsmitte des Alurings (siehe Abb. 9) steht die Zugstange auf beiden Seiten des
                         Sensors mindestens 20 mm über.

                                                                    -12,5   0 +12,5




                                                 20                                                  20
                      Abb. 9: Abmessungen Zugstangenanschluss
                      Eine werkseitige Anpassung der MSC7210 für Zugstangenanschlüsse mit abweichenden ferromagnetischen
                      Eigenschaften ist möglich.




LVP-25-Z20-5-CA                                                                                                           Seite 13
                                                                                       Contents

            1.    Note ........................................................................................................................................... 15

            2.    Technical Data .......................................................................................................................... 16

            3.    DIP Switches ............................................................................................................................ 17
            3.1   Setting of DIP Switches.................................................................................................................................... 17
            3.2   DIP Switch Settings for Pull Rods .................................................................................................................... 18

            4.    Power Supply, Sensor and Signal Output ............................................................................... 19
            4.1   Wiring ............................................................................................................................................................... 19
            4.2   Power and Signal ............................................................................................................................................. 19
            4.3   Sensor .............................................................................................................................................................. 20
            4.4   Signal Performance, Connection ..................................................................................................................... 21

            5.    Calibration of the Measuring System ...................................................................................... 22

            6.    Requirements for Measuring Object ....................................................................................... 23




LVP-25-Z20-5-CA
Note

                  1.          Note
                  This assembly instructions describes the start up operations of tool clamping sensor LVP-25-Z20-5-CA
                  with analogue signal conditioning electronics „MSC7210-U“ (Voltage output 2 ... 10 VDC) respectively
                  „MSC7210-I“ (Current output 4 ... 20 mA).

                  i    For more information, see the instructions „induSENSOR LDR“ series.

                                                             5.8
                                                             (.23)
                                                     90°                                                     3-pole cable with shield
                                                                                                             ø1.8 (.07) mm / AWG 28
                                                             4
                                                             (.16)




                                                                        45°
                                  ø19.85 (.78)
                                   ø18 (.71)




                                                                                                                                                  English
                                     0.3x45°                                             0.3x45°                    ø13 (.22)
                       Legend        (.01x45°)                       38 (1.49)           (.01x45°)

                         mm                      5                                                                              5.5
                       (inches)                  (.19)                                                                          (.22)
                                                     ø11.5




                                                                                                                ø11.5
                                                                                                ø10
                                                                                 (.31)
                                                         (.45)




                                                                                                     (.39)




                                                                                                                    (.45)
                                                                              ø8


                                                                                Measuring ring
                                                                 Shaft ø8 (.31) and ø10 (.39) (ferromagnetic)
                                                                 not included in supplied items

                  Fig. 1: Dimensional drawing LVP-25-Z20-5-CA, not to scale


LVP-25-Z20-5-CA                                                                                                                         Page 15
Technical Data

                  2.        Technical Data
                  Model                          LVP-25-Z20-5-CA-AC
                  Article                        2617008
                  Measuring principle            LVP
                  Measuring range                25 mm
                  Target (not included)          Article 0482218 for shaft diameter 8 mm
                                                 Article 0482219 for shaft diameter 10 mm
                  Resolution                     0.01 mm
                  Linearity                      typical ±1 % FSO (0.25 mm)
                  Dynamics                       150 Hz (-3 dB)
                  Housing                        Stainless steel
                  Temperature stability sensor   < ±0.01 % FSO / °C
                  Temperature range sensor       -40 °C ... +150 °C
                  Protection class sensor        IP 67
                  Medium                         Air, oil
                  Electronics                    Series MSC7210
                  FSO = Full Scale Output




LVP-25-Z20-5-CA                                                                             Page 16
DIP Switches

                  3.                       DIP Switches
                  3.1                      Setting of DIP Switches
                  Prior connection of tool clamping sensor LVP-25-Z20-5-CA to the signal conditioning electronics the DIP
                  switches within the electronics MSC7210 have to be set.

                  i    The tool clamping sensor can be used with pull rods with diameter 8 (.31) mm or diameter 10 (.39) mm.

                       Pull rods with diameter 8 (.31) mm and diameter 10 (.39) mm: settings according procedure Chapter 2.2.
                  For a proper function of the sensor the DIP switches within the electronics MSC7210 have to be set.

                  i    The specified system parameters like linearity, temperature stability are related to DIP switch setting.

                            Please consider the value and setting of the respective DIP switches (2-1, respectively 4-3-2-1) during
                            setting procedure.
                  Setting of DIP switch to position „ON“: see Picture 2




                                                                                                                                                                                                                               English
                  SCREW-PAD-3
                                                                                                     J1    2 1
                  X4                       GND                          Ub



                                                                                                                  GAIN
                                           IN                           FB-
                                  Top
                            R4




                                           R                             Q                                  ON
                                           RC                          FB+                     R53
                       FREQUENZ            Out                           Q
                                                                                               Top
                             ON
                       1




                                                                                                           2 1                        4 3 2 1
                                                                                                     J3




                                                                                                                              J2




                                                                                                                                                      PHASE
                                                                                                                       TEST
                       2
                       3




                                                                                                            ON                                  ON
                                                J6        J5      J7
                       4




                       J4

                                                                                          R2         20k
                                                                                                 3
                                                                                          1           3
                                                                  Output




                                                                                                                              Prim+
                                                                           Shield




                                                                                                              Shield
                                        Power




                                                                                                                                               Sec+
                                                           Ognd




                                                                                     R1
                                                 Pgnd




                                                                                                                                       Prim-




                                                                                                 3
                                  X1                                                10k                     X2
                                                                                                                                                                   SCREW-PAD-3




                                                        Riacon 07                         1           3                       Riacon 07
                                                                                                 3                                                            X4

                                                                                          1            3
                                                                                          R3         20k
                                   RIA07-05                                                                  RIA07-04

                                                                                                                                                                                 Fig. 2: Sensor controller MSC7210



LVP-25-Z20-5-CA                                                                                                                                                                                                      Page 17
DIP Switches

                  3.2             DIP Switch Settings for Pull Rods
                                                                                   DIP switch settings for pull   DIP switch settings for pull
                  Frequency
                                                            J2
                                                                                    rods with dia. 8 (.31) mm     rods with dia. 10 (.39) mm




                             ON
                   4 3 2 1
                                                                 4 3 2 1               Switch J2 (Phase)              Switch J2 (Phase)




                                                                           PHASE
                                                                      ON                 1            OFF               1             ON
                             J4
                                                                                         2            OFF               2            OFF
                                                                                         3             ON               3            OFF
                                                                                         4            OFF               4             ON
                  Fig. 3: Amplifier electronics, DIP switch for phase
                  (J2) and frequency (J4)                                            Switch J4 (Frequency)          Switch J4 (Frequency)
                                                                                         1            OFF               1            OFF
                                                                                         2             ON               2            OFF
                                                                                         3             ON               3             ON
                                                                                         4            OFF               4            OFF

                                                    Gain                           DIP switch settings for pull   DIP switch settings for pull
                                                  J1 2 1                            rods with dia. 8 (.31) mm     rods with dia. 10 (.39) mm

                                                      ON
                                                                                        Switch J1 (Gain)               Switch J1 (Gain)
                                                     Test                               1             ON               1             ON
                                                  J3 2 1
                                                                                        2             OFF              2             OFF
                                                      ON
                                                                                        Switch J3 (Test)               Switch J3 (Test)
                                                                                        1             OFF              1             OFF
                  Fig. 4: Amplifier electronics, DIP switch for gain
                  (J1) and test (J3)                                                    2             ON               2             ON


LVP-25-Z20-5-CA                                                                                                                        Page 18
Power Supply, Sensor and Signal Output

                      4.        Power Supply, Sensor and Signal Output
                       The minimum bending radius of the power and output cable PC710-6/4 (available as accessory) is
                       24 (.94) mm. All connections for the power supply / sensors / signal output are on the electronics (see Fig. 5).
                       Cable characteristics: External diameter of the cable: 3.0 (.12) ... 5.0 (.19) mm
                                                 Lead wire:                       0.08 (.003) ... 0.25 (.009) mm 2

                      4.1       Wiring
                      Please note that the housing has to be opened in order to connect the sensors and to wire the output and
                      power cable.
                            Please loosen the screws.
                            Put the signal cable which was designed according to Chapter 3.3 through the cable gland.
                            Strip off the leads-insulation of the output and power cable. Please mount appropriate wire end ferrules
                            on the braids and the shielding; therefore please use an appropriate crimping tool.




                                                                                                                                          English
                            Put the output and power cable through the cable gland provided.
                            Please wire the lead braids in the controller.
                            Completely assemble the controller and tighten the screws.
                      4.2       Power and Signal

                                                                     Terminal block X1      Function
                                                                     Power                  Power supply 18 ... 30 VDC
                                                                     Pgnd                   Ground (0 V)
                       Shield
                       Output                                        Ognd                   Signal - ground (0 V)
                        Ognd
                        Pgnd                                                                MSC7210-U: Signal (2 ... 10 VDC)
                                                                     Output
                       Power                                                                MSC7210-I: Signal (4 ... 20 mA)
                                                                     Shield                 Screen power supply cable
                       Fig. 5: Pin assignment for power and signal, terminal block X1

LVP-25-Z20-5-CA                                                                                                                Page 19
Power Supply, Sensor and Signal Output


                      i     Please only use shielded cables.

                      When using more than one controller you have to notice the following:
                      - The shields of the output and power cables have to be potential-free.
                      - The shields of the output and power cables must not be connected electrically.
                      - The controller housings must not be connected electrically.
                      4.3       Sensor

                      Assembling the sensor cable for connecting the electronics
                            Remove the cable sheath of the sensor cable to a length of approximately 50 (1.96) mm. Do not damage
                            the shielding braid.
                            Please slightly twist the shielding braid.
                            Push and shrink the shrink tubing which is 40 (1.57) mm long (article no. 0181001) over the shielding
                            braid.
                            Insulate the 3 braids at 6 mm and tin them afterwards.
                            Push and shrink the shrink tubing which is 25 (.98) mm long (article no. 0182003) on the cable.
                            Position the shrink tubing in such way that the lead braids are covered at 5 (.19) mm.
                            Please crimp the wire end ferrule (article no. 0325048) to the end of the shielding braid.




                                                                               Fig. 6: Finished sensor cable


LVP-25-Z20-5-CA                                                                                                               Page 20
Power Supply, Sensor and Signal Output

                      4.4      Signal Performance, Connection

                       The output signal increases if the plunger is inserted. In the case that the counter performance is required
                       (i.e. that the signal reduces if the plunger is inserted), the connections prim+ and prim- have to be chan-
                       ged.
                       Please note that a sensor cable which was designed by you may not be longer than 10m due to the EMC
                       standards.
                                                                   Terminal block X2        Color of wire (Sensor cable)
                                                                   Shield                   Shield Sensor cable
                                                                   prim+                    brown
                                                         Shield    prim-                    white
                                                         Prim+
                                                         Prim-     sec+                     green
                                                         sec+




                                                                                                                                        English
                       Fig. 7: Pin assignment for sensor, terminal block X2

                      i     A white wire end ferrule is connected to the shielding of the sensor cable.




LVP-25-Z20-5-CA                                                                                                               Page 21
Calibration of the Measuring System

                       5.       Calibration of the Measuring System
                                                                                       Legend         -12.5      0 +12.5
                                                                                         mm            (.49)            (.49)
                                                                                        (inches)




                                                      Drag-bar with target ring                                Sensor

                       Fig. 8: Calibration of the measuring system LVP-25-Z20-5-CA

                       1. Note measured value with pull rod including target completely outside the sensor -> offset value of the
                          sensor.
                       2. Move pull rod including target within the sensor till measured value is equal to offset value noted measu-
                          red under 1. -> electrical zero of the sensor.
                       3. Move pull rod including target -12.5 (.49) mm from the electrical zero of the sensor to start of measuring
                          range (see Fig. 8).
                       4. Adjust trimmer R1 (see Fig. 2) to a value of 2 VDC (MSC7210-U) respectively 4 mA (MSC7210-I).
                       5. Move pull rod including target to position +12.5 (.49) mm from the electrical zero of the sensor to end of
                          measuring range (see Fig. 8, position +12.5 (.49) mm).
                       6. Adjust trimmer R3 (see Fig. 2) to a value of 10 VDC (MSC7210-U) respectively 20 mA (MSC7210-I).
                       7. Repeat steps 3 – 6 till required calibration accuracy is reached.
                       The measuring system is calibrated, when the output signal at position -12.5 (.49) mm equals 2.0 VDC
                       (4 mA) and at position +12.5 (.49) mm equals 10 VDC (20 mA).

                       i    If you need an invested signal output (pull rod moves in direction of +12.5 (.49) mm position with decre-
                            asing signal), change the connections prim+ and prim- on the terminal block X2.




LVP-25-Z20-5-CA                                                                                                                 Page 22
Requirements for Measuring Object

                      6.       Requirements for Measuring Object
                      The measuring object consists of a pull rod (outer diameter 8 (.31) mm respectively diameter 10 (.39) mm) and
                      the aluminium rings (inner diameter 8 (.31) mm respectively diameter 10 (.39) mm). The aluminium ring shall
                      be glued on to the pull rod (e.g. with „LOCTITE 2701“).
                      The specified data is tested with a target rod with:
                       - A material with good ferromagnetic qualities. Materials with low ferromagnetic qualities are not suitable for
                         the measurement. The values documented in the test protocol are gathered with a pull rod with diameter
                         8 (.31) mm, material number 1.8519.05.

                      i     The specified system parameters like linearity and temperature stability could be affected by the mate-
                            rial used for the pull rod.
                       - In the middle position of the aluminium ring (see Fig. 9) the pull rod must overlap not less than
                         20 (.79) mm on both sides of the sensor.
                                                                      -12.5    0 +12.5
                                                  Legend               (.49)       (.49)
                                                    mm




                                                                                                                                         English
                                                    (inch)




                                                20 (.79)                                               20 (.79)
                      Fig. 9: Dimension of pull rod interface
                      A special adaption of the electronics MSC7210 to a customised pull rod with deviating ferromagnetic charac-
                      teristics can be performed by the manufacturer.




LVP-25-Z20-5-CA                                                                                                               Page 23
MICRO-EPSILON MESSTECHNIK GmbH & Co. KG
                                                        X977X226-A021090HDR
Königbacher Str. 15 · 94496 Ortenburg / Deutschland
Tel. +49 (0) 8542 / 168-0 · Fax +49 (0) 8542 / 168-90
info@micro-epsilon.de · www.micro-epsilon.de            *X977X226-A02*

								
To top