					Fluke Digital Multimeter Model 289 Fluke Multimeter in India Kolkata, Pune, Delhi, Mumbai, Rajkot, Ahemdabad, Hyderabad, Bangalore, Bengaluru, Chennai, Vizag, Vishakapatnam, Haldia, Durgapur, Jamshedpur, Best Price Low Cost Fluke 289




                                      Phone: 033 32916080
                                      Fax: 033 30222923
                                      Email: info@industrialindia.com


                                                                     New Fluke 289
                                            True-rms Industrial Logging
                                           Multimeter with TrendCapture
                                                                                                                                                                                                                                                                                                           Technical Data


                                                                         New diagnostic functionality for maximizing
                                                                         productivity in the plant.
                                                                         The new 289 is the next generation high performance industrial logging
                                                                         multimeter designed to solve complex problems in electronics, plant
                                                                         automation, power distribution, and electro-mechanical equipment.
                                                                         With the ability to log data and review it graphically on-screen, you can
                                                                         solve problems faster and help minimize downtime. Let the new 289
                                                                         be your watchdog for systems
                                                                         or processes while you are off
                                                                         solving other problems.


                                                                         Equipped with new
                                                                         functionality
                                                                         • New – Large 50,000 count,
                                                                                                   1/4 VGA dot matrix display
                                                                                                   with white backlight                                                                                                                         TrendCapture displays vAC logged data.
                                                                         •                         New – Logging function with                                                                                                              • New –           button. On board
                                                                                                   expanded memory for unat-                                                                                                                    help screens for measure-
                                                                                                   tended monitoring of signals                                                                                                                 ment functions. Unsure about
                                                                                                   over time. Using on-board                                                                                                                    a function—go to that function
                                                                                                   TrendCapture users can graph-                                                                                                                and press the “i” button.
                                                                                                   ically review logged readings
                                                                                                   without needing a PC. Store                                                                                                              •   Real time clock for automatic
                                                                                                   up to 10,000 readings over                                                                                                                   time stamping of saved
                                                                                                   time.                                                                                                                                        readings
                                                                         •                         New – Save multiple logging                                                                                                              •   Relative mode to remove test
                                                                                                   sessions before pc download                                                                                                                  lead resistance from low ohms
                                                                                                   is necessary                                                                                                                                 or capacitance measurements
                                                                         •                         New – Two terminal 50 ohm                                                                                                                •   True-rms ac voltage and
                                                                                                   range with 1 milliohm resolu-                                                                                                                current for accurate measure-
                                                                                                   tion, 10 mA source current.                                                                                                                  ments on non linear signals
                                                                                                   Useful for measuring and                                                                                                                 •   Measure up to 10 A (20 A for
                                                                                                   comparing differences in motor                                                                                                               30 seconds)                                                                  N10140
                                                                                                   winding resistance or contact                                                                                                            •   100 mF capacitance range
                                                                                                   resistance.                                                                                                                              •   Peak capture to record tran-
                                                                         •                         New – Low Pass filter for                                                                                                                    sients as fast as 250 µs                                          R




                                                                                                   accurate voltage and frequency                                                                                                           •   Withstands hazardous 8,000
                                                                                                   measurements on adjustable                                                                                                                   volt spikes caused by load
                                                                                                   speed motor drives and other                                                                                                                 switching and faults on indus-           • Optically isolated communica-
                                                                                                   electrically noisy equipment                                                                                                                 trial circuits and complies with           tion port for transferring data
                                                                         •                         New – LoZ Volts. Low imped-                                                                                                                  second edition IEC and ANSI                to pc (usb cable and software
                                                                                                   ance voltage function for                                                                                                                    electrical safety standards.               optional)
                                                                                                   eliminating ghost voltages.                                                                                                              •   Optional magnetic hanger                 • Limited lifetime warranty
                                                                                                   Also recommended when test-                                                                                                                  for easy setup and viewing
                                                                                                   ing for absence or presence of                                                                                                               while freeing your hands for
                                                                                                   live power.                                                                                                                                  other tasks
Fluke Digital Multimeter Model 289 Fluke Multimeter in India Kolkata, Pune, Delhi, Mumbai, Rajkot, Ahemdabad, Hyderabad, Bangalore, Bengaluru, Chennai, Vizag, Vishakapatnam, Haldia, Durgapur, Jamshedpur, Best Price Low Cost Fluke 289




                                                                         Specifications
                                                                                  Function                                                                                                                                                  Range and Resolution                                             Basic Accuracy
                                                                                  DC volts                                                                                                                                                  50.000 mV,500.00 mV, 5.0000 V, 50.000 V,                             0.025 %
                                                                                  AC volts                                                                                                                                                  500.00 V, 1000.0 V                                               0.4 % (true-rms)
                                                                                  DC current                                                                                                                                                500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA,                          0.15 %
                                                                                  AC current                                                                                                                                                5.0000 A, 10.000 A                                               0.7 % (true-rms)
                                                                                  Temperature                                                                                                                                               -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)                        1.0 %
                                                                                  (excluding probe)
                                                                                  Resistance                                                                                                                                                50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ,                             0.05 %
                                                                                                                                                                                                                                            500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
                                                                                  Capacitance                                                                                                                                               1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF,                        1.0 %
                                                                                                                                                                                                                                            100.0 µF, 1000 µF, 10.00 mF, 100.0 mF
                                                                                  Frequency                                                                                                                                                 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz,                         .005 %
                                                                                                                                                                                                                                            999.99 kHz


                                                                                  Additional Functions/Features                                                                                                                                                          Fluke 289
                                                                                  Multiple on screen displays                                                                                                                                                                Yes
                                                                                  True-rms ac bandwidth                                                                                                                                                                    100 kHz
                                                                                                                                                                                                                                                                                                                   Ordering
                                                                                                                                                                                                                                                                                                                   information
                                                                                  dBV/dBm                                                                                                                                                                                    Yes
                                                                                                                                                                                                                                                                                                                   289        True-rms Industrial
                                                                                  DC mV resolution                                                                                                                                                                          1 µV                                              Logging Multimeter
                                                                                  Megohm range                                                                                                                                                                          up to 500 MΩ                                          with TrendCapture
                                                                                  Conductance                                                                                                                                                                             50.00 nS                                 Optional accessories
                                                                                                                                                                                                                                                                                                                   FVF-SC2 FlukeView® Forms
                                                                                  Continuity beeper                                                                                                                                                                          Yes                                           Software with Cable
                                                                                  Battery/fuse access                                                                                                                                                                    Battery/fuse                              TLK289 Industrial Test Lead Set
                                                                                  Elapse time clock                                                                                                                                                                          Yes                                   i400    AC Current Clamp
                                                                                                                                                                                                                                                                                                                   i410    AC/DC Current Clamp
                                                                                  Time of day clock                                                                                                                                                                          Yes                                   80BK    Integrated DMM
                                                                                  Min-max-avg                                                                                                                                                                                Yes                                           Temperature Probe
                                                                                                                                                                                                                                                                                                                   TPAK    Magnetic Hanging Kit
                                                                                  Duty cycle                                                                                                                                                                                 Yes
                                                                                                                                                                                                                                                                                                                   C280    Soft Case
                                                                                  Pulse width                                                                                                                                                                                Yes
                                                                                  Isolated optical interface                                                                                                                                                                 Yes
                                                                                  Auto/touch hold                                                                                                                                                                            Yes
                                                                                  Reading memory                                                                                                                                                                             Yes
                                                                                  Log to PC                                                                                                                                                                                  Yes
                                                                                  Interval/event logging                                                                                                                                                                     Yes
                                                                                                                                                                                                                                                                                                                Fluke. Keeping your world
                                                                                  Logging memory                                                                                                                                                                    up to 10,000 readings                              up and running.®


                                                                         General                                                                                                                                                                         Relative humidity: 0 to 90 %
                                                                         specifications                                                                                                                                                                  (0 t 37 °C), 0 to 65 % (37 °C to
                                                                                                                                                                                                                                                         45 °C), 0 to 45 % (45 °C to 55 °C)
                                                                         Maximum voltage between any                                                                                                                                                     Electromagnetic compatibility:
                                                                         terminal and earth ground:                                                                                                                                                      EMC EN61326-1
                                                                         1000 V                                                                                                                                                                          Vibration: Random vibration per
                                                                         Battery type: 6 AA alkaline                                                                                                                                                     MIL-PRF-28800F Class 2
                                                                         batteries, NEDA 15A IEC LR6                                                                                                                                                     Shock: 1 meter drop per IEC/EN
                                                                         Battery life: 100 hours minimum,                                                                                                                                                61010-1 2nd Edition
                                                                         200 hours in logging mode                                                                                                                                                       Size (HxWxL): 22.2 cm x 10.2
                                                                         Temperature:                                                                                                                                                                    cm x 6 cm (8.75 in x 4.03 in x
                                                                         Operating: -20 °C to 55 °C                                                                                                                                                      2.38 in)
                                                                         Storage: -40 °C to 60 °C                                                                                                                                                        Weight: 870.9 g (28 oz)
                                                                                                                                                                                                                                                                                              Industrial Supply Syndicate
                                                                         2 Fluke Corporation 289 True-rms Electronic Logging Multimeter with TrendCapture                                                                                                                                     54, Ezra Street, Kolkata - 700 001, INDIA
                                                                                                                                                                                                                                                                                              Phone: 32916080, 22356676 Fax: +91 33 30222923
                                                                                                                                                                                                                                                                                              Email: info@industrialindia.com Website: www.industrialindia.com

				