AC/DC Clamp meter DC Clamp Meter Dual Display Clipon Meter Indian Manufacturer Dealer Kusam Meco Kusum Meco Clampon meter Tong Tester Auto power off Tongue Tester Tongtester AC DC Clamp Meter Clamp Tester Bset Clampmeter Kolkata Delhi Bombay Mumbai Pune Delhi Patna Pune Hyderabad Bangalore Vizag Vishakapatnam Ahmedabad Vadodra Baroda Mohali Haldia Jamshedpur Ranchi Kharagpur Bhillai Low cost best Quality good accuracy 0.1mv Digital Clamp meter
DIGITAL DUAL DISPLAY
An ISO 9001:2000 Company AC / DC CLAMPMETER
GENERAL SPECIFICATIONS :
ï Display : 3¾ digit LCD with a max. Reading of 3999. ï Safety Standards : The meter is up to the
MODEL KM 2782
ï Range control : Autorange Control standards of IEC 1010 double insulation,
ï Polarity : Automatic negative polarity indication Pollution Degree 2, Overvoltage CAT II
ï Zero adjustment : Automatic ï Clamp opening size : 45 mm
ï Over range indication : only the “OL” display ï Operating Temperature : 32 ~ 104°F (0 ~ 40°C),
ï Low battery indication : The “ - +
” is display when Humidity < 80% R.H.
the battery Voltage is below 7.2V. ï Storage Temperature : -4 ~ 104°F ( -20 ~ 60°C),
ï Auto Power Off : 30 minutes after stopping the switch Humidity < 90% R.H.
or no push button, the meter automatically enter to ï Power Supply : 9V zinc ~ carbon battery.
power off mode. Push button or run switch, auto ï Dimension : 225(H) x 77(W) x 45(D) mm
power off disable. ï Weight : approx. 330g. (Including battery)
ELECTRICAL SPECIFICATIONS : KM 2782
Accuracies are ±(% of reading + digit) at 23°C ± 5°C Less than 70% R.H.
DC VOLTAGE AC VOLTAGE
Range Accuracy Resolution Range Accuracy Resolution Frequency
400 mV ±(0.8%rdg + 5digits) 0.1 mV 4 V 1 mV
4 V 1 mV 40 V ±(1.5%rdg + 5digits) 10 mV 50~400Hz
40 V ±(1.0%rdg + 5digits) 10 mV 400 V 100 mV
400 V 100 mV 750V ±(2.5%rdg + 5digits) 1 V 50~100Hz
1000 V ±(2.5%rdg + 5digits) 1 V Average sensing, calibrated to rms of sine wave
Overload protection : 1000V DC/750Vrms AC Overload protection : 1000V DC /750Vrms AC;
Impedance : 10MW , More then 100MW on 400mV scale Impedance : 10MW .
AC CURRENT DC CURRENT
Range Accuracy Resolution Range Accuracy Resolution
400A ±(3.0%rdg + 10digits) 0.1 A 200A 3.0% of rdg+10digits 0.1 A
±(3.5%rdg + 10digits) 0~800 3.5% of rdg+10digits Preliminary Sepcifications
0~800
1000A 1 A 1000A 1A
800~1000 ±(6.5%rdg + 10digits) 800~1000 6.5% of rdg+10digits
Average sensing, calibrated to rms of sine wave Overload protection : 1000Arms with 60 Seconds.
Overload protection : 1000Arms with 60 Seconds.
Frequency : 50 ~ 400Hz
RESISTANCE CAPACITANCE
FREQUENCY Range Accuracy Resolution Range Accuracy Resolution
Range Accuracy Resolution 400 W ±(1.5%rdg + 15digits) 0.1 W 40nF 6.0% of rdg+10digits 10PF
10 Hz 0.01 Hz 4 kW 1 W 400nF 100PF
1.2% of rdg+10digits 40 kW 10 W 4µ F 3.5% of rdg+5digits 1nF
10 Hz 0.1 Hz ±(1.2%rdg + 15digits)
400 kW 100 W 40µ F 10nF
1000 Hz 1 Hz
4 MW 1 kW 100µF 6% of rdg+10digits 100nF
10 kHz 0.8% of rdg+5digits 10 Hz
40 MW ±(2.5%rdg + 15digits) 10 kW Overload protection : 250V DC/250Vrms AC
100 kHz 100 Hz
1000 kHz 1 kHz Overload protection : 250V DC/250Vrms AC
10 MHz 2.0% of rdg+10digits 10 kHz DIODE AND AUDIBLE CONTINUITY TEST
Overload protection : 250V DC/250Vrms AC Range Description Test condition
Sensitivity : Range of input voltage : 1.5V~1 0V,
Display read approx. Forward DC current approx. 0.4mA
if input voltage over range,need adjust Forward voltage of diode. Reversed DC Voltage Approx. 1.5V
VOLTAGE (TRUE RMS) Built-in buzzer sounds if
Open circuit voltage aprox. 0.5V
Frequency reisitance is less than 90 W
Range Resolution Accuracy
400 mV 0. 1 mV ± 2.0% of rdg+15 digits 40Hz - 1kHz Overload protection : 250V DC/250Vrms AC
4 V 1 mV ± 1.2% of rdg+10 digits 40Hz - 1kHz TEMPERATURE
40 V 10 mV ± 1.2% of rdg+10 digits 40Hz - 10kHz Range Accuracy Resolution
400 V 100 mV ± 1.0% of rdg+10 digits 40Hz - 400Hz -20~150°C 3°C +2 < 400°C 1°C
750 V 1 V ± 1.0% of rdg+10 digits 40Hz - 400Hz °C 150~300°C _
> 400°C 1°C
3.0% of rdg + 2 digits
1. Input Impedance : >10MW Ohm ACV True RMS. 300~1000°C 3.5% of rdg + 10 digits _
> 400°C 1°C
2. Overload Protect :1000V DCV or ACV peak value.
3. Press “Range” button for select ACV 400mv range. Overload protection : 36V DC/36Vrms AC