Docstoc

Model 831 V1.5

Document Sample
Model 831 V1.5 Powered By Docstoc
					  Model 831 V1.512
SoundTrack LxT V1.512



      New features
      New modules

       June 2009
Audio - VOIP

• Used to reduce costs
• Have muted all incoming lines to reduce background
  noise
• If you have question, please use CHAT window. We will
  un-mute your particular line.
Recent Highlights and Successes

• (35) Model 831-FF for Canadian IRSST. Win against B&K
  – Firmware and software tweaks to 831/DNA
  – Excellent dealer support
• (9) NMS018-FF for Thai Pollution Control Department
• ERA Corporation – approached Larson Davis for strategic partnership
  – Former Rannoch/BAE/Tracor – specialized in airport noise monitoring
  – Software competitive to offering from Lochard/B&K
  – Airport Noise Management Suite
  – First wins in US vs B&K/Lochard
• Environmental Noise Seminar / Open House
Introduction
• V1.512                                                  Highlights
  –   SLM Utility-G3                      • SLM Utility-G3
  –   SoundTrack LxT (major)                   – “Masking” options
  –   Model 831 (maintenance)                  – QC Tonality
  –   SDK update                               – USB Stick > 2GB
                                          • LXT
• Changes                                      – Printer support
  –   No standalone SLMScreenGrabber           – Alignment with 831 V1.5 (stability)
  –   Printed manual on request           • 831
  –   Remove screwdriver + screws              – Many SR fixes
  –   WS001 is part if LXT/831, not ACC
                                                               Next
                                          •   DNA 4.3.5.6 (QC feature, EPNL)
                                          •   DNA Remote
                                          •   831 V1.6 Airport
                         831
                                          •   831 V2.0 Room Acoustics
                                          •   831 V2.1 (PC) Building Acoustics
                                          •   831 V2.2 FFT
                         LxT              •   831 V2.3 Building Acoustics
V1.512 Files and documents
     FTP Site: Product Updates                    New FAQ
• 831 V1.512 release history        • Sizing Battery and Solar Panel
• Model 831 Manual (F)                  – Includes MS Excel worksheet
• 831 V1.512 known problems         • What is CER-831-E
                                        – For -40 C/F temperatures
• SLM Utility-G3 V1.512             • AA Battery run time
   – w/ DNA + Blaze demo ~ 135 MB   • QC Tonality
   – “small” without demo ~ 34 MB   • RUSH Service orders
• SLM Utility-G3 Manual (E)         • 831 LOG and FST parameters
• 831LXTSDK library                 • Masking options on 831 and LxT
                                    • Options & Features Cross
• LXT V1.512 release history          Reference for 831 and LxT
• SoundTrack LxT Manual (G)         • PRN003 LXT Printer
• LXT V1.512 known problems

• Installation instructions
ftp.larsondavis.com/LDReps

• Updated
• See product / Graphics for new
  pictures
  – 831, HVM, LXT, EPS, …
• See POSTERS
  – You can print locally in any size
NEW PRICELIST

                  831                                LXT
• CER-831-E = -40 ºC ~ 70 ºC test    • LXT-MEM2G = 831-MEM2G
• CBL170 – wind & power w/o 831-     • Standard = LXT-MEM250
  INT
• 500 ft / 160 m NMS solution for    • PRN003 = MCP7870 +MPS160 +
  426A12 without 831-INT               CBL159
  – CBL171 – power + control (2ft)
  – EXHxxx – control cable
  – CBL152xxx – signal cable
                                                   831+LXT
• CBL174 USB cable to EPS029/30-     • M2106.11 Retrofit adaptor for
  831                                  EPS2106/8 to EPS2106/8-2
• EPS2112 Rainhat replaces           • Spare battery door: 831-BDOOR,
  EPS2110                              LXT-SRV06/5
• S831.07 Retrofit adaptor for
  EPS031/2 onto TRP011
                                     • Reduced microphone pricing
                                     • NEW PRICELIST UPDATE ON
                                       JULY 1ST
PRN003 Printer

• LxT V1.512 supports USB printer
  – Full screen
  – General overview
• Martel Instruments (UK)
  – MCP 7870 (NiMH battery)
  – MPS 160 (charger)
  – CBL159 / CBL138 USB cable
  – Supports “translated” fonts


• NOTE
  – Only for LIVE file
     • Not accessible for saved file
  – Planned for 831
EPS2112 Rainhat and CBL170

                                          DB9 connector
                                          * 12V power
                                          * Logic In
                                          * Logic Out
                                          * Wind speed / tach
     EPS2110  EPS2112
                                          * 3 A/D channels (wind direction,
                                          temperature, humidity)
                                          * control GND
                                          * power GND




   CBL170 – 831 + power + weather (RPM)
             Power = PSA027
500 ft – 160 m long cables with 426A12

• Limitation of acoustical signal in                                   Maximum Level (dB) as function of frequency and cable length
                                                                                       (426A12-FF and 426A12-RI)
   – AMPLITUDE
   – FREQUENCY                                               20

   CBL152-xxx (xxx  500 ft)




                                           Frequency (kHz)
                                                             15                                                                       123 dB
                                                                                                                                      132 dB
                                                             10
                                                                                                                                      143 dB

• Control signal and power                                   5


   – Limited to 20 ft                                        0
                                                                  10              76            152             305          610 m

   – Long distance possible with:                                 35             250            500            1000         2000 ft
                                                                                            Cable Length
      • Extra power supply (CBL171 – see
        below)
      • EXHxxx extension cable




  CURRENTLY NOT POSSIBLE WITH 831-INT DOCKING STATION
External USB Connector on EPS030-831 / EPS029-831

                                    • Cable goes into 831

                                    • Download data without
                                      opening the box
                                    • Read battery status
SLM Calibration - Uniformity
• SLM CER for 831 and LXT                   • 824
  – includes PREAMP and SLM Body              – CER-824
  – Includes 831-RPT or LXT-RPT               – CER-PREAMP
  – Does not include MIC                      – CER-MIC
  – CER-831
  – CER-LXT1
  – CER-LXT2
• CER-MIC
  – Certification of the microphone
• CER-831-E
  – Includes CER-831
  – Adds environmental testing
• CER-426A12
  – Calibration and recertification with
    microphone
  – Environmental testing for temperature
    and humidity testing
  – Does not include CER-MIC
    microphone certification
831 / LxT Battery Life
CAL250 CAL200 CAL150
• Restyling
• Compliance to standards
  – IEC 60942-2003 & ANSI S1.40:2006
     • CAL250 S/N 4408  4444 & 5000 
     • CAL200 S/N 5209 
     • CAL150 S/N 3441 
  – IEC 60942-2003 & ANSI S1.40:1984
     • CAL250 S/N ???  4404 & 4450  4484
     • CAL200 S/N 2888  5208
     • CAL150 S/N 2314  3440
  – IEC 60942 (~ < 2001)
     • In case of repair, suggest upgrade.
Masking options

SPECIAL FOR DISTRIBUTORS
• Show customer real options
• Reset via “format/restore”
STRONG RECOMMENDATION TO UPDATE

• Please run an upgrade campaign and make it easy for your
  customers to upgrade

• LXT  better stability, features
• 831  fixed several SR bugs
Thanks
• Recording of meeting will be made available shortly
• Recording posted to FTP
• Next presentation
  – Audiometer Calibration – update of AUDIT V2.0
  – AMC493A
  – AEC102, -103, -104



Suggestions / Questions are Welcome
adelandsheer@pcb.com

				
DOCUMENT INFO
Shared By:
Categories:
Stats:
views:24
posted:3/20/2011
language:English
pages:17