reader 6pp by sdsdfqw21

VIEWS: 11 PAGES: 6

									fingerprint
         READER
         Biometrics are the only way to confirm the
         presence of the correct person.

         TSSI’s Verid+ family of fingerprint readers are
         designed to provide a flexible range of
         solutions for improving the security of access
         control systems.
EACH VERID+ UNIT CONTAINS THE COMPLETE ENROLMENT,
VERIFICATION AND DATABASE SOFTWARE IN A SINGLE
WALL MOUNTED HOUSING. UNITS CAN BE NETWORKED
USING RS485 TO OFFER AUTOMATIC CONFIGURATION AND
SYNCHRONISATION OF THE UNIT’S DATABASES. THREE
VERSIONS OF VERID+ ARE AVAILABLE; VERID+ FOR
INSTALLING INTO EXISTING SYSTEMS BETWEEN THE
CARD READER AND THE DOOR CONTROLLER, VERID+PIN
CONTAINING AN INTEGRAL KEYPAD AND VERID+PROX
WITH AN INTEGRAL PROXIMITY READER.




  Verid+ a fingerprint          Verid+PIN fingerprint      Verid+Prox fingerprint
  verification system           verification with          verification with integral
  for connection to an          integral keypad.           proximity reader.
  external reader.


Each unit is capable of both enrolment and verification.
 Verid+
                   HOW IT WORKS




                                                                        Using Verid+ with input devices
                                                                        Verid+ is able to accept inputs from a variety of input
Users are enrolled onto the system by capturing a template              devices or readers which are connected to Verid+
from their fingerprint and storing it against their PIN number.         through the terminal block on the inside of the back
When the user enters their PIN number Verid+ recalls the stored         panel. (See table on back page.)

template and compares it with the presented finger. If the              Wiegand: Requires Weigand '0' and Wiegand '1' signals.
template and finger match, the correct person is present and            Option of TimeOut and CardPresent if available.
Verid+ sends the PIN number to the access control system.
                                                                        Wiegand - PIN Formats:
                                                                        a) Wiegand 2601 standard
                                                                        b) “General Wiegand” - data from a reader which
                                                                        always outputs in the same direction. Weigand
                                                                        inputs up to 64 bits in length are accepted.
Enrolment
                                                                        c) Corporate 1,000 standard
Enrolment is supervised by the system manager who must have
SuperUser status. Users are enrolled by presenting their card or        ISO Track 2 - Magtek or Omron timing. Requires Clock
PIN number to Verid+, the unit scans the fingerprint 3 times and        and Data signals. Timeout and CardPresent signal options.

creates a record known as a template. This template is stored           Data must conform to ISO7811 “track 2” format. Max
in the unit with the person’s PIN or card number.                       PIN length is 16 characters (excluding start/end
                                                                        sentinels). If more than 16 characters are sent, Verid+
                                                                        will shorten it and use the first 16 characters as the PIN.
Verification
Users are verified by presenting their card or PIN number to            WaterMark Magnetics®: Requires Clock and Data signals.
Verid+, the unit scans the fingerprint once and makes a PASS            TimeOut and CardPresent signal options. Supports all
                                                                        registered LRC, or non-LRC, WaterMark formats.
(good match) or FAIL (bad match) decision.
                                                                        PIN Keypad: Verid+ can be used with an external
Data Output                                                             Wiegand output keypad, this must be Wiegand type.
                                                                        Alternatively use Verid+PIN which includes an
After a successful template match the PIN data only is sent from
                                                                        integral keypad.
Verid+. The data is output in the same format as it is received
from the PIN entry device.                                              Proximity cards: Verid+ can be used with a range of
                                                                        external proximity readers, these are mostly of the
                                                                        Wiegand type. Alternatively use Verid+Prox which
If a PASS (good match) is obtained Verid+ can be configured to:         includes an integral proximity reader.
• Send the card or PIN number to the Access Control system
• Send a signal direct to a magnetic door lock to cause it to open      MIFARE Smart cards and other HID iclass formats:
                                                                        Contact TSSI for further information.
• Display a green PASS signal on Verid+
If a FAIL (bad match) is obtained Verid+ can be configured to:
• Send an error code to the Access Control system
• Send NO signal to a magnetic door lock, the door remains closed    • Storage of templates on track 3 of a standard
• Display a red FAIL signal on Verid+                                  magnetic card. Verid+ must be suitably
                                                                       configured to accept template entry from track
Template Storage / Management                                          3, and the card must also contain PIN data on
Verid+ supports six methods for storing and managing templates:        track 2. A suitable encoding system is
• Storage of templates in internal memory. As standard up to           required (enVision).
  3,500 users can be stored in internal memory. Optional memory      • Storage of templates/PIN numbers on 2D
  upgrades are available to extend this to 15,000 users.               barcodes (PDF417 format). These barcodes can
• Transfer via RS232 to a PC, or from a PC. This is possible under     be attached to documents or papers. A suitable
  software control or by using TSSI's Verid Manager programme.         encoding system (enVision) and a suitable
• Transfer via RS485 between Verid+ units. Once installed, the         optical reader and interface are required.
  dedicated RS485 network will automatically transfer                  Contact TSSI for further information.
  information on newly enrolled, deleted or updated templates.       • Via browser and the TCP/IP versions of Verid+.
RS232 Interface                                                               Configuration             Standard Configurations
The 3.5mm jack connector on the underside of the unit provides                All configuration         Verid+
RS232 communications. Verid Manager, from TSSI, offers a variety              settings can be           Input: General Wiegand
of template management options including capturing or writing                 altered by RS232          Output: General Wiegand
the complete database, capturing or writing individual records and            commands.                 LED Control: Internal
                                                                                                        Database: Internal
storing records in a PC for back-up or transfer to other units. More          The detailed              Card Present: Not Set
details are available in the document “Verid Manager User Guide”.             command set is            TimeOut: Not Set
                                                                              contained in the full     Security Level: 3
                                                                              Verid+ manual.
RS232 Communication Protocol:
                                                                                                        Verid+PIN
Characters are sent at 19,200 baud, handshaking is not                        Alternatively the         Input: Keypad
provided and the character format is:                                         configuration can be      Output: ISO Track 2 (Magtek)
Start Bits 1        Data Bits 8                                               set using Verid           LED Control: Internal
                                                                              Manager software          Database: Internal
Parity Bits None    Stop Bits 1
                                                                              from TSSI (requires a     Card Present: Not Set
                                                                              PC running Windows        TimeOut: Not Set
Message Format:                                                               95/98/2000™).             Security Level: 3
Communication between the reader and PC uses the                                                        PIN length: 4 digits

following frame format in both directions:
                                                                                                        Verid+Prox
• Header, Length, Identifier, Data, CRC                                                                 Input: Wiegand 2601
• Header - a sequence of four bytes indicating the start of a                                           Output: Wiegand 2601
  message: 76, 9A, 4D and C6 hex                                                                        LED Control: Internal
                                                                                                        Database: Internal
• Length - two bytes which define the number of bytes following                                         Card Present: Not Set
  the length field                                                                                      TimeOut: Not Set
• Identifier - a single byte which indicates the type of message.                                       Security Level: 3
• Data - a data field (where required) which can be of variable
  length dependent on the message
• CRC - two bytes covering the Identifier and Data fields                 user places a finger on the unit which is then
                                                                          apparently checked, but will always pass). These
TCP/IP Interface                                                          settings should be used with care but are useful
An alternative backplate provides a TCP/IP connection in place of         in certain circumstances.
the Verid+ RS485 network. This allows programs such as Verid
Manager and Verid Brower to run across the building network.              Security Levels - Users
                                                                          During the enrolment of each user (and
RS485 Network functions                                                   SuperUser), one of various security levels can be
If the Verid+ units are connected using the dedicated RS485               assigned to the individual user:
network the following tasks will take place automatically -               • “Global setting”: The user will adopt the
normally without any PC or user intervention:                               security setting of the Verid+ unit
                                                                          • “Level 1 (low) to 5 (high)” checks the
• Add, delete or update a user - PIN and template data will                 fingerprint to differing degrees of accuracy
  immediately be broadcast to all other Verid+ units on the               • “Any fingerprint” and “PIN Input Only”
  network. (This feature can optionally be turned off using                 can also be assigned to the user. A user's
  Verid Manager)                                                            individual security level will override the global
• Configure new units on the network - newly added units will               level set on the Verid+ unit being used.
  automatically adopt the configuration of other units on the
  network, e.g. PIN input format. (This feature can optionally be         Error Codes Output
  turned off using Verid Manager)                                         If the finger fails to match the template, the PIN
                                                                          data output is:
User Interface
All Verid+ units have an LCD display and LEDs to indicate the
                                                                              PIN format               Error code
status of the unit and guide the individual through the
verification process. In the standard configuration all the LEDs              Wiegand 2601             26 bit data: “000000”

are controlled by the Verid+ unit. If required the Green PASS                 ISO Track 2              ISO card with data: “000000”
and Red FAIL LEDs can be controlled by the host.
                                                                              General Wiegand          26 bit data: “000000”

                                                                              Watermark                Registered Watermark card:
Security Levels - Verid+
                                                                                                       “000000”
Each Verid+ unit can be set to one of 7 “Global Setting” security
levels. Level 1 (low) to 5 (high) to check the fingerprint to differing       Keypad                   26 bit data: “000000”
                                                                              (Wiegand type only)
degrees of tolerance. Alternatively, Verid+ can be set to “PIN
only” (i.e. no fingerprint checking) or “Any fingerprint” (i.e. the
                                                                          In units running firmware VP6.00 and later error codes can be
                                                                          suppressed if required or different codes used for finger and
                                                                          card failures.
Installation:
All connections are made via the interface PCB mounted on the rear plate. The terminals are grouped into functional blocks:


   Block      Terminal              Section             Function                                          Block      Terminal      Section                 Function
   no.        label                                                                                       no.        label

   J2         OV                    Power input         Power supply input: OV                            J8         TOC clock     Template-on-card        Template on card clock

   J2         +12V                  Power input         Power supply input: +12V                          J8         TOC data      Template-on-card        Template on card data

   J3         OV                    Door controller     OV (for door controller)                          J9         Park          RS485                   Storage for Network
                                                                                                                                                           Termination Jumper
   J3         Clock (D1)            Door controller     Output to door controller clock or Wiegand ‘1’                                                     for RS485

   J3         Data (DO)             Door controller     Output to door controller - Data or Wiegand ‘0’   J10        OV            Ext RS232 comms         0V for RS232

   J3         Card Present          Door controller     Output to door controller - Card present          J10        Rx2           Ext RS232 comms         Receive for RS232 #2

   J3         Timeout               Door controller     Output to door controller - Timeout               J10        Tx2           Ext RS232 comms         Transmit for RS232 #2

   J4         OV                    LED I/P             0V (for LED control)                              J10        Rx1           Ext RS232 comms         Recieve for RS232 #1

   J4         Pass                  LED I/P             External LED control PASS LED                     J10        Tx2           Ext RS232 comms         Transmit for RS232 #1

   J4         Fail                  LED I/P             External LED control FAIL LED                     J11        Network       RS485                   Network Termination
                                                                                                                     Termination                           Jumper for RS485
   J5         N.O                   Relay               Normally open contact
                                                                                                          J12        A             RS485 IN                RS485 - A wire IN
   J5         Common                Relay               Common for relay
                                                                                                          J12        B             RS485 IN                RS485 - B wire IN
   J5         N.C                   Relay               Normally closed contact
                                                                                                          J12        GND           RS485 IN                Ground for RS485
   J6         OV                    PIN power output    Output to external device: 0V
                                                                                                          J13        A             RS485 OUT               RS485 - A wire OUT
   J6         +5V                   PIN power output    Output to external device: 5V 150mA max
                                                                                                          J13        B             RS485 OUT               RS485 - B wire OUT
   J6         +12V                  PIN power output    Output to external device: 12V 100mA max
                                                                                                          J13        GND           RS485 OUT               Ground for RS485
   J7         OV                    PIN Device          0V (for PIN inputs)

   J7         Clock (D1)            PIN Device          Input from PIN Clock or Wiegand ‘1’

   J7         Data (DO)             PIN Device          Input from PIN Data or Wiegand ‘0’

   J7         Card Present          PIN Device          Input from PIN - Card Present
                                                                                                                  Specifications
   J7         Timeout               PIN Device          Input from PIN - Timeout
                                                                                                                  Case Details:
                                                                                                                  Height:                190mm
                                                                                                                  Width:                 120mm
Installation and Fixing Details                                                                                   Depth:                 60mm
                                                                                                                  Weight:                500 g
Attach the backplate to the wall using the three fixing holes
                                                                                                                  Temperature Operation: 0°C to 40°C
provided (see diagram). Note a gap of 8mm must be left between                                                    Storage:               -10°C to 50°C
the fixing plate and any adjacent object to accommodate the                                                       Humidity Range @ 40°C:10% to 80% (non condensing)
housing. Connect all system wiring to the screw terminals before                                                  Power Requirements:    10V to 16V,
                                                                                                                                         500mA max
connecting the ribbon cable from the Verid+ unit to the terminal
                                      plate. Insert the top of the                                                In order to meet the requirements of EN60950 Verid+
                                      housing over the back plate                                                 should be powered from an SELV supply. Verid is
                  38mm
                                      and fasten using the two                                                    designed to comply with UL294. Verid+ complies with
                                                                                                                  the following EMC requirements:
                 18mm                 bolts on the base of the
             5mm dia
                                      unit. For maximum security                                                  Europe
                            84mm      we recommend the use of                                                     EN55022 Emissions (class A)
            76.5mm                                                                                                EN50130-4 Immunity
                                      anti-tamper bolts (size M4
                                                                                                                  Warning: this is a “Class A” product. In a domestic
                                      (metric)). Use backplate as                                                 environment this product may cause radio interference
 178mm
                                      a template to drill holes.                                                  in which case the user may be required to take
            Wiring port 20mm dia                                                                                  adequate measures.

                                    16mm
                                                       Postioning:
                                                                                                                  North America
                                                       TSSI recommends Verid is                                   FCC rules CFR47 part 15 limit A Verid+ has been tested
           25mm                    20mm
                                                       installed 1.2 - 1.4m above                                 and found to comply with the limits for a Class A digital
                         8mm                           floor level and a minimum                                  device, pursuant to part 15 of the FCC rules. These
                                                                                                                  limits are designed to provide reasonable protection
                                                       of 75mm between a side
                       108.5mm                                                                                    against harmful interference when the equipment is
                                                       wall and the Verid unit.                                   used in a commercial environment. This equipment
                                                                                                                  generates, uses and can radiate radio frequency energy
Maintenance                                                                                                       and, if not installed and used in accordance with the
                                                                                                                  instruction manual, may cause harmful interference to
Verid+ is essentially maintenance free. The finger plate does not                                                 radio communications. Operation of this equipment in
need cleaning in normal use. The housing may be cleaned with a                                                    a residential area is likely to cause harmful interference
soft cloth and non-abrasive liquid detergent.                                                                     in which case the user will be required to correct the
                                                                                                                  interference at his own expense.
Ref: TSSI_FB_V+_FR_MAY05
Verid+ is a trademark of TSSI. WaterMark is a registered trademark of TSSI. Windows 98, 2000 & XP are trademarks of Microsoft Corporation.




                                                                                                                                             TSSI, Rutland House, Hargreaves Road, Groundwell Industrial Estate, Swindon. SN25 5AZ. United Kingdom
                                                                                                                                                                     Tel: +44 (0) 1793 747700 Fax: +44 (0) 1793 747701 Email: marketing@tssi.co.uk


                                                                                                                                                                                                      www.tssi.co.uk

								
To top