CABLE TEST BRIDGE KMK 7

W
Document Sample
scope of work template
							                                                                                        CABLE TEST
                                                                                        BRIDGE
                                                                                        KMK 7
)
 Hz)
Ω
kΩ




VA



e
                                                                                          Copper Cable
                                                                                          Test Equipment




                                                  Phone 02 9972 9244 Fax 02 9972 9433
                                                  Unit 1, 176 South Creek Road, Cromer NSW 2099
                                                  Email sales@sebakmtaus.com                        www.sebakmtaus.com
       Advanced Utility Solutions Pty Ltd. T/A.
                  KMK 7                                                                                                                              Da
                  Application                                                        Main Menue                                                      Fea
                  The KMK 7 is a computerized automatically balanced fault           All feasible measurements and possibilities are listed in the
                  location bridge with integrated acceptance and series tests.       “Main menue”. The individual measurements are selected by        Mic
                  The splash-proof design makes the instrument especially suit-      operating the corresponding key.                                 aut
                  able for rough field use. The excellent sensitivity makes it an                                                                     Ind
                  ideal test set for measurements on trunk and local cables. For                                                                      and
                  acceptance tests, using the KMK 7, the insulation resistance,
                  loop resistance, resistance difference, mutual capacitance and                                                                      Eas
                  interference voltages can be measured. The unit is specially                                                                        Inp
                  designed for easy fault location and acceptance tests.                                                                              tem
                  Measurement of insulation resistance, loop resistance and DC-                                                                       Sto
                  fault location can be called up via special keys. All other mea-
                                                                                                                                                      RS
                  surements are activated via main- and submenus. In addition
                  to the automatic balancing facility, the KMK 7 can also be bal-                                                                     Pow
                  anced manually. The DC-fault location can be carried out with                                                                       exte
                  the Murray Loop B, the Double Bridge Loop and the Three
                                                                                                                                                      Spl
                  Point Method. For measurements according to the “Double
                                                                                                                                                      wa
                  Bridge Loop” the switching at the cable end (open and short
                  circuit) can be carried out automatically with the remote switch                                                                    Fau
                  FGK 1.                                                             Measurement display                                              –M
                  All DC-fault location measurements are indicated as a resis-       Standard cable length of 10,000 m                                –D
                  tance measurement, a length measurement or as a percentage                                                                          –T
                                                                                     lx distance to the fault position
                  of the cable length. For cables with sections of different con-                                                                      a
                                                                                     ly distance from fault position to the cable end
                  ductor diameters, the cable section and the conductor diame-
                                                                                     Mw average value                                                 –R
                  ter have to be entered. The KMK 7 automatically indicates the
                  section number and the distance to the fault from the near end.                                                                     –B
                  The cable test set KMK 7 is suitable for AC- and DC-fault loca-                                                                     – Lo
                  tion on loaded and unloaded cables.
                                                                                                                                                      Ma
                                                                                                                                                      – in
                                                                                                                                                      –c
                                                                                                                                                      – lo
                                                                                                                                                      – re
                                                                                                                                                      –m
                                                                                                                                                      – in




                                                     Phone 02 9972 9244 Fax 02 9972 9433
                                                     Unit 1, 176 South Creek Road, Cromer NSW 2099
                                                     Email sales@sebakmtaus.com                                            www.sebakmtaus.com
Advanced Utility Solutions Pty Ltd. T/A.
                     Data of the KMK 7
                     Features                                                Technical Data:
the
 by                    Microprocessor-controlled measurement with            DC Fault Location:
                       automatic balancing facility                          Measuring       Murray Loop B
                       Indication of the test circuit, test procedure        modes for       Double Bridge
                       and test results on the graphic LCD-display           shorts and      Three Point
                                                                             shunts:
                       Easy menu-driven operation
                                                                             Measuring       loop resistance up to 14 kΩ
                       Input of the cable temperature or                     range:          fault resistance up to 100 MΩ
                       temperature measurement via test sonde
                                                                             Test voltage:   a) 100 V DC; (Ri = 60 kΩ)
                       Storage of test results                                               b) 500 V DC; (Ri = 300 kΩ)
                       RS 232 serial link                                    Sensitivity:    0.25 µV / Bit
                       Power supply by NC-accumulator,                       Resolution:     10 –5 of twice the cable length
                       external 12 V DC or mains supply                      Accuracy:       0.1 % ±1 Digit (of cable length)
                       Splash-proof with cover open,
                       waterproof with cover closed                          AC Fault Location:
                       Fault location measurements as per:                   Measuring       200 m up to100 km
                       – Murray Loop B                                       range:          Rmin ≥ 100 kΩ
                       – Double bridge method                                Test            a) 200 m up to 10 km
                                                                             voltage:           Ueff = 16 Vss; f = 77 Hz;
                       – Three point method for high-
                                                                                                Ri = 100 kΩ
                         and low ohmic shunts
                                                                                             b) 2 km up to 100 km and
                       – Resistance discontinuities                                             loaded cables:
                       – Breaks                                                                 Ueff = 50 Vss; f = 4.5 Hz;
                                                                                                Ri = 400 kΩ
                       – Loaded und unloaded cables
                                                                             Sensitivity:    50 µV/ Bit
                       Maintenance and series tests
                                                                             Resolution:     a) f = 4.5 Hz: 0.05 ‰
                       – insulation resistance                                                  of cable length
                       – conductor/pair identification                                       b) f = 77 Hz: 0.2 ‰
                                                                                                of cable length
                       – loop resistance
                                                                             Accuracy:       0.5 –1 % ± 1 Digit (of cable length)
                       – resistance difference
                       – mutual capacitance
                                                                             DC Interference Voltage:
                       – interference voltage
                                                                             Measuring       up to 100 V (Re > 10 MΩ)
                                                                             range:
                                                                             Accuracy:       2.5 % ±1 Digit
                                                                                             (of measuring range)


                                                                             AC Interference Voltage:
                                                                             Measuring       up to 60 Vss (Re > 10 MΩ)
                                                                             range:
                                                                             Accuracy:       5 % ±1 Digit (of measuring range)




                                                            Phone 02 9972 9244 Fax 02 9972 9433
                                                            Unit 1, 176 South Creek Road, Cromer NSW 2099
                                                            Email sales@sebakmtaus.com                                          www.sebakmtaus.com
      Advanced Utility Solutions Pty Ltd. T/A.
                  CABLE TEST BRIDGE KMK 7

                  Technical Data:

                  Resistance:
                  Measuring range:         up to 14 kΩ (loop resistance)
                  Test voltage:            100 V DC; Ri = 60 kΩ
                  Measuring mode:          bridge measurement (auto)
                  Sensitivity:             0.25 µV / Bit
                                            Rs
                  Resolution:              105                                      Technical Data:
                  Accuracy:                0.1 % ±1 Digit
                                           (of measuring range)
                                                                                    Mutual Capacitance:
                  Resistance difference (WU) :                                      Measuring range:          a) 2 nF up to 2 µF (f = 77 Hz)
                  Measuring range: a) up to 10 % of Rs                                                        b) 200 nF up to 15 µF (f = 4.5 Hz)
                                   b) up to 50 % of Rs                              Test voltage:             a) f = 77 Hz; 16 Vss; Ri =100 kΩ
                  Test voltage:    100 V DC; Ri = 60 kΩ                                                       b) f = 4.5 Hz; 50 Vss; Ri =300 kΩ
                  Measuring mode: bridge measurement (auto)                         Resolution:               a) 0.1 nF (meas. ≤ 500 nF)
                  Sensitivity:     0.25 µV / Bit                                                                 f = 77 Hz
                  Resolution:        Rs                                                                       b) 0.5 nF (meas. ≤ 5 µF)
                                    105
                  Accuracy:        0.02 % ±1 Digit (of Rs )                                                      f = 4.5 Hz
                                                                                    Accuracy:                 0.5 – 3 % ±1 Digit
                  Insulation Resistance:                                                                      of measuring range
                  Measuring        a) Test mode
                  modes:           b) Limit indication 3/30 GΩ                      General Data:
                                   c) Bridge meas. up to 100 GΩ                     Permissible ambient temperature:
                  Test voltage:    a) 100 V DC; Ri = 60 kΩ                          Nominal operating temp.: –10 °C …+50 °C
                                   b) 500 V DC; Ri = 300 kΩ                         Operating temp. limits:   –15 °C … +55 °C
                  Accuracy         5 –15 % ±1 Digit (of measur. range)              Transport and
                                                                                    storage temp.:            –25 °C … +60 °C
                  Resistance discontinuity:                                         Power Supply:             a) 210 V … 250 V AC;
                  Measuring range: above 5 Ω (>10 % of Rs )                                                      50 – 60 Hz; 115 V opt.
                  Measurements:    AC- and DC-fault location                                                  b) Internal NC-accu;
                                   in combination                                                                6 – 8 h cont. operation;
                  Accuracy:        2 % ±1 Digit (of meas. range)                                                 charging time 5 hours
                                   (Rs > 100 Ω)                                                               c) External DC source;
                                                                                                                 12 V DC (9–15 V); P > 10 VA
                  Accessoires:                                                      Weight:                   6.3 kg
                  Standard:                Test leads and clips                     Dimensions:               340 x 180 x 270 mm
                  Optional:                Printer, temperature sensor              Housing:                  yellow plastic case with handle
                                           remote switch FGK 1                      Vibration and drop test: VDE 0411




                  DIN ISO 9001

                                                                                     ®




                    Product Range : Instruments and Test Vans for Fault Location in Power and Telecommunication Networks
                    and for Leak Detection in Water and Sewage Networks • Cable and Pipe Locators • Seminars
                    SebaKMT Sales • 96148 Baunach/Germany • Phone +49 - (0) 9544 - 68 0 • Fax +49 - (0) 9544 - 2273
                    E-mail : sales@sebakmt.com • Internet : www.sebakmt.com

                    Technical data subject to change without notice.                                      KMK 7_GB_1/00_ML_Ru




                                                        Phone 02 9972 9244 Fax 02 9972 9433
                                                        Unit 1, 176 South Creek Road, Cromer NSW 2099
                                                        Email sales@sebakmtaus.com                                         www.sebakmtaus.com
Advanced Utility Solutions Pty Ltd. T/A.

						
Related docs
Other docs by hjkuiw354
Wedding Checklist - Wedding Planner
Views: 4078  |  Downloads: 3
MINORS ON LICENSED PREMISES
Views: 101  |  Downloads: 0
Marine Operations Port Lincoln Port Rules
Views: 43  |  Downloads: 0
Merit-Based Equity Scholarships
Views: 2  |  Downloads: 0