Wiring centres are designed to simplify wiring and circuit checking. The TC100 does this with an easy
to understand manual suited to all popular central heating and hot water systems. Adequate wiring
space, large terminals, cable access points and cable clamps add to the simplicity of the TC100.


 2 Port Motorised Valve System (S - Plan)
   Room Thermostat
   Model Nos RT200
                                                          WIRING CENTRE TC100
             RT300
             RT500                                                                                                                       Cylinder Thermostat
                                                                                                                                              Model No. CT100

      N                                               1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16                                                     HWS
                                                                                                                                                 (NO)
                                                                                                                                                           HWC

            3   2
                                                                                                                   Note                                    (NC)
                                                                                                                                                  2         1     14
                                                                                                                   Links shown
      N L SL                              L   AC                                                                   Should be made
                                                                                                      E
                                          N   Mains IN                                                             by the installer
                                              protected                                               E
                                          N   by 5amp
                                                                                                                                                            C     15
       E                                                                                              E
                                          N   fuse
                                                                                                      E
                                          N                                                                                                                  E
    NB. Neutral not required
    on RT300 & RT500



    Yellow/Green                E
    Blue (N)                    N
    Brown (L)               4                                                                                               N E                            N E
                                                                                                                       12                             13
    Orange CH Call (C)      6

    Grey CH (N0)            7                                                                                          L N E                          L N E
                                                                                                                       Boiler                          Pump
  CH Motorised Valve
  Model Nos. MV222
             MV228
                                                                                             N   11           10   9
                                                              8    Brown (L)
           11 12                                              6    Orange CH Call (C)
                                                                                            N L 1 2 3 4
                                                              7    Grey HW (N0)
                     Optional Frost
     N L SL          Thermostat                           E        Yellow/Green
                     Model No. FT100                                                         E
                                                          N        Blue (N)
                                                                  HW Motorised Valve         Programmer
                                                                  Model No. MV222            Model No. EP200



Note: links shown on diagram should be made by the installer.                                                                         RT200

                                    For ‘S Plan’ link
                                    2-4
                                    7 - 11
                                    8 - 14                                                            CT100                              EP200




The TC100 Wiring Guide assumes that the Installer can identify from
the boiler, pump and controls literature to hand, the mains supply
and switch terminals.

                                                                                        2 X 2 PORT MOTORISED VALVE SYSTEM (S PLAN)
  3 Port Motorised Valve System (Y - Plan)
              Room thermostat
              Model Nos RT200
                                                                                          WIRING CENTRE TC100
                        RT300                                                                                                                    Note
                        RT500                                                                                                                    Links shown           Cylinder Thermostat
                                                                                                                                                 Should be made             Model No. CT100
                                                                                      1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16                     by the installer             HWS       HWC
                 N                                                                                                                                                            (NO)      (NC)
                       3    2                                                                                                                                          16      2         1     14

                 N L SL                                                    L  AC                                                          E
                                                                           N Mains                                                        E
                                                                              IN                                                                                                         C     15
                                                                           N                                                              E
                                                                           N                                                              E
                 E                                                         N                                                                                                             E


              NB. Neutral not required
              on RT300 & RT500


                                                                                                                                                    12   N E                       13   N E
                     11 12

                                           Optional Frost
                N L SL                     Thermostat                                                                                                L N E                         L N E
                                           Model No. FT100                                                                                           Boiler                         Pump

                                                                                                        N
              Blue N                                    N                                                   11 8      10      9
              White (CH Call)                       4                                                   N L 1 2 3 4
              Orange (HW Call)*                     6
              Grey (HW SAT)                         7
                                                                                                        E
              Yellow/Green                               E
                 Motorised valve                          * Varying voltages will be present on             Programmer
                                                          orange conductor depending on                     Model No. EP200
                  Model Nos. MV 322                       switch state of valve.
                             MV 328



Note: links shown on diagram should be made by the installer.
           For ‘Y Plan’ link
                                                                                                                                                               RT200
           2-4
           7-8
           8 - 16
           13 - 14                                                                                                                     CT100                        EP200




All wiring must be to latest I.E.E. wiring
regulations - BS 7671:2001 and carried out by a
competent, qualified installer.

Warning                                                                                                                       1 X 3 PORT MOTORISED VALVE SYSTEM (Y PLAN)
Salus Controls plc. accepts no liability for any loss or damage arising from any
errors or omissions that may be inadvertently contained within this diagram.




Salus Controls plc
Enterprise Park, Bala Gwynedd, LL23 7NL
Regional offices, England & Scotland.
Web: www.salus-tech.com Email: sales@salus-tech.com