Docstoc

Humidifying Air Purifier

Document Sample
Humidifying Air Purifier Powered By Docstoc
					                      SiBE81-909


                       Preliminary




Humidifying Air Purifier
SiBE81-909




                                                                                        Air Purifier
                                                                                                            MCK75JVM-K

                    1.Introduction ......................................................................................................2
                    2.Precautions for Use..........................................................................................5
                        2.1 Required Conditions ............................................................................5
                        2.2 Applicable Room Area .........................................................................5
                    3.Functions .........................................................................................................6
                    4.Specifications ...................................................................................................7
                       4.1 Specifications ......................................................................................7
                       4.2 Dimension ............................................................................................9
                       4.3 Wiring Diagram ..................................................................................10
                       4.4 Packaging Drawing ............................................................................11
                    5.Operation Manual...........................................................................................12
                       5.1 Safety Precautions ............................................................................12
                       5.2 Names and Operation of Each Part ...................................................16
                       5.3 Sensitivity Settings of the Dust Sensor ..............................................22
                       5.4 Installation .........................................................................................23
                       5.5 Preparation of Remote Controller ......................................................24
                       5.6 Attach the Filter .................................................................................25
                       5.7 Water Tank Preparations ...................................................................26
                       5.8 Air Purifying Operation ......................................................................28
                       5.9 Humidify and Air Purifying Operations ...............................................29
                       5.10 How to Operate with Remote Controller ............................................30
                       5.11 How to Use the Recyclable Deodorizing Cartridge ...........................32
                       5.12 Quick Reference Table of Maintenance ............................................34
                       5.13 Care and Cleaning .............................................................................36
                    6.Optional Accessories .....................................................................................48
                       6.1 Dimensions ........................................................................................48
                    7.Troubleshooting .............................................................................................50
                        7.1 Basic Inspection ................................................................................50
                        7.2 Check Before Requesting Servicing ..................................................53
                        7.3 Frequently Asked Questions .............................................................56
                        7.4 Troubleshooting .................................................................................57
                        7.5 Check ................................................................................................64




Humidifying Air Purifier                                                                                                                1
Introduction                                                                                                                                                                   SiBE81-909



1. Introduction
      “Clean Humidification”and “High Airflow Rate Purifying”are realized.

                 Both “full humidification”and “full dust collection”can be used.


          Full Humidification                                                                        Full Dust Collection
       3 features for “Clean                                                                         High airflow rate suction dust
                                                                                                        collection: 7.5m3/min
       Humidification”
          Antibacterial humidifying filter                                                          High hydrostatic thin-type fan is
          Silver ion antibacterial effect                                                                     equipped .
          Unsoaking humidifying rotor


       Max. humidifying                                                                               Full Deodorization
       amount: 600mL/h
       (Vaporization humidifying                                                                      Photocatalyst & Streamer
                                                                                                             discharge
       system)
                                                                                                       +   Recyclable deodorizing
       Slim tank capacity: 4L
                                                                                                                 cartridge
       Double path mixing structure


          Of course, deodorization is [full-scale]                                                      Recyclable




                                                                                                                                          Test condition: Air test room
    Full Humidification & Full Dust                                                                                          Optimum
                                                                                                                                          (W 3700 × D 3700 × H 2400) ∗equivalent to 13 m2
             Collection                 Speedy and rich humidifying into all corners                                       humidificat
                                                                                                                            ion can be    room
                                                                                                                          obtained only
                                                                      Humidifying the room into all corners
       Humidification comparison with the                                 by high airflow rate and new
                                                                                                                          by 15-miniute
                                                                                                                             operation
                                                                                                                                          Room temperature: 21°C measured with an existing
                    humidifier                                          vaporization humidifying system
         When humidifying in turbo mode
                                                                                                                                          model, 27°C with a new model
         (vaporization system)

             At start                 5 min. later                  10 min. later                       15 min. later




      When humidifying in low mode            Start humidifying evenly                  Full moisturizing of the living space
      (vaporization system)




                                             Moisture flows to the upper space.                    Slow speed




    Full humidification       Clean design: 3 features for Clean Humidification

                            How to feed water
                    Water comes from the tank to the tray.
                    Using the proprietary [water feeding                 Waterwheel
                    system with waterwheel], the humidifying
                    filter does not soak in water, so that the
                    mildew proliferation and bad odor are                         Supply water
                    restrained.                                                    to the filter                 Rotate


           Antibacterial humidifying
     1               filter                                                                Water surface

                              Adsorbs water
                Silver ion
     2      antibacterial effect
                                                                                              Silver ion eliminates bacteria from
                                                                                                       water in the tray.
           Unsoakinghumidifying rotor
     3         Waterwheel built-in
                                                                                                    Water tank
             humidifying structure)




                                                                                                      Silver ion




2                                                                                                                                                                   Humidifying Air Purifier
SiBE81-909                                                                                                                                                        Introduction




    Full humidification
                               New Design: High hydrostatic thin-type powerful fan
                                                                                                                                                  Airflow
                        “Double Path Mixing Structure”                                        Humidified air
                                                                                                                                               temperature
                                                                                                                                                increases

                          Newly designed thin-type fan                                                                                            2˚C
                                                                                    Dry air                                                (Compared with
                                                                                                                                           a model without
                          Vaporized air and non-vaporized air                                                                                double path
                          are mixed and discharged by shifting                                                                             mixing structure)

                          the humidifying filter from the fan.
                          This design prevents drop of the                                                                                          High
                          airflow temperature and restrains                                                                                      hydrostatic
                                                                                                                                                thin-type fan
                          drop of the room temperature.



                                                                Air to be humidified
                                                                                                                                                  Fan
                                                                                                                                               thickness
                                                                                                                                               20mm
                                                                                                                                               thinner than
                                                                                                                                               the existing
                                                                    When                                                                           model
                                                                humidifying
                                                               in turbo mode

   Electric dust collection area is positioned in front of     50 dB                                            Humidifying filter
    the humidifying rotor where little pressure loss is         (7.5m3/min)
     observed and quiet sound is heard even if the
            humidifying operation is performed.




       Full Humidification & Full Dust
                 Collection                            Sensitive Control
     6-step airflow mode (Top in the market)                                                  [Top operation area]

   When automatic airflow mode is selected, humidity, dust or odor
   sensor detects the air condition in the room and optimal operation
   is performed within a mode range from quiet to high.

    <Pollen> operation                                           Air purification
                                                                                                 (Automatic)       (Quiet)             (Low)       (Standard)


       In this operation , pollens are caught before they drop on
       the floor with gentle air draft by switching airflow between
                          “Standard”and “Low”.                                                       (Pollen)                (Turbo)              (High)



      [Monitor display]
                           Dust sensor lamp             Humidity indicator lamp                           Odor sensor lamp




             Simple and sensitive settings are available.




                                                     Compact Design
                                                                                                                                               Compact
                          “Slim Tank”                                                                            268mm
                                                                                                                    mm                            No.1∗
         The water tank is positioned at the front.
            Structure for easier maintenance                                                                                              ∗ Comparison of a
                                                                                                                                          new model and an
                                                                                                                                          air purifier with the
                                                                                                                                          humidifier (class:
                                                                                                                                          airflow rate =
                                                                                 mm
                                                                              395mm                                                       7.5m3/min.)
                                                                                                                                          (As of July 16, 2008)




    Water tank
                                                                        Unsoaking
                                                                      humidifying rotor




                                                                              [In maintenance]
                                                                              Structure for easier
                                                                                    removal




Humidifying Air Purifier                                                                                                                                                    3
Introduction                                                                                                                                                                        SiBE81-909



                                                                                                                                            [Test Conditions]
                                                                                                                                            •Airflow rate: 7.5m3/min
                                                   Full Deodorization
                                                                                                                                            •Test room: About 10m2 space
               Formaldehyde removal               [Photocatalyst & Streamer Discharge]                                                      •Conforming to WG standard for reviewing the MLIT
                     amount and
                equivalent ventilation
                corresponding value:
                                                  technique strongly decomposes and                                                          evaluation test method of sick building overall
                    46m2room∗                     removes odor, formaldehyde and so on.                                                      project
                                                                                           Extraordinary decomposing force                  ∗Corresponding value when the mechanical
                    Formaldehyde Removal Performance (Corresponding ventilation)                 approved by academy
                                                                                           Streamer discharge is a prominent Daikin         ventilation specified in the building standard law is
                                                                                        technology, which shows more than 1,000 times
         70                                                                                 decomposing force for the general glow
                                                                                         discharge, and gets [A prize of the Institute of
                                                                                                                                            carried out.
                                                                                                     Electrostatics Japan].
         65                     Improved removal performance
                                56m3/h: corresponding ventilation value                               Streamer discharge
                                              46m2 room
         60
                                                                                                 Area where fast electron is generated

         55
                   The existing air purifier model of 54m3/h
         50        =Corresponding ventilation value of 43m2
                                          room                                             Electron is discharged in three-dimensionally



                                                                                        Catalyst can be self-generated, so that
                                    Duration of service (month)
                                                                                      deodorizing filter required no replacement




          Washable and recyclable deodorizing cartridge
         “Washable and recyclable deodorizing cartridge” which is regenerated
         by the streamer decomposing force is a standard equipment

                                                        System Chart
         New Product
                                              The cartridge will be                                            At the entrance
                                         2    regenerated in the special
                                              pocket after using it for 2                   Remove the odor
                                                                                               slowly.
                                              months.

                                   Streamer Pocket



                                                                                                                        The cartridge
                                                                                                                        can be set in
                                                                                    Recyclable                            various
          Deodorizing                                                                                                     places.
            agent is
          regenerated                                         Recyclable
             by the
           Streamer
                                                          deodorizing cartridge
             force                Repeatedly              which can be washed               1     Set in a smelly place.
                            3
    The deodorizing effect is
                                  reusable             ∗ This cartridge is made of the components
    restored over one night.      cartridge            same as “deodorizing catalyst” equipped with
                                                       the air purifier.




4                                                                                                                                                                        Humidifying Air Purifier
SiBE81-909                                                                                               Precautions for Use



2. Precautions for Use
2.1      Required Conditions

  Power Supply
1φ, 220-240/220-230V, 50/60Hz

  Miscellaneous
  •This product is for home use. Do not use for special purpose.
  •This product is for indoor use only. Do not use in bathroom or outdoors as it is not water/condensation proof.
  •Do not modify this product.


2.2      Applicable Room Area

                    Air purifying operation   Humidifying operation

       m2                     46                       —


Note) The applicable room area is appropriate for the operating unit of maximum fan speed (HH).
      Applicable room area indicates the space where a certain amount of dust particles can be removed in 30 minutes.
      (JEM1467)




Humidifying Air Purifier                                                                                                  5
Precautions for Use                                                                           SiBE81-909



3. Functions




                                                                      MCK75JVM-K
      Category                                  Functions



Structure             Odor sensor
                      Dust sensor
                      Humidity sensor
                      Temperature sensor
Health & Clean        Flash streamer discharge
                      Catechin pre-filter
                      Titanium apatite photocatalytic filter
                      Bio-antibody filter                               –
                      Attached pleated filter (sheets)                1+6
                      Humidifying filter
                      Deodorizing catalyst
                      Recyclable deodorizing cartridge
Monitor               Odor sensor lamp
                      Dust sensor lamp
                      Humidity indicator lamp
Operation             Automatic air-purifying airflow rate
                      Manual air-purifying airflow rate
                      Anti-pollen mode (air-purifying)
                      Automatic humidifying airflow rate
                      Manual humidifying airflow rate
                      Anti-pollen mode (humidifying)
                      Humidity setting
                      Turbo mode
                      Negative ion                                      –
Maintenance           Quick-wipe panel
                      Water supply indicator
                      Plasma ionizer cleaning indicator
                      Streamer unit cleaning indicator
                      Air-purifying filter replacement indicator
                      Humidifying filter replacement indicator
Convenience           OFF TIMER (hours)                              1·4·8
                      Child proof lock
                      Brightness adjustment
                      Deodorizing cartridge recycle function
                      Remote controller storage
Other Functions       Automatic OFF function for turnover
                      Standby electricity saving                   (below 0.5W)
Remote controller     Wireless remote controller                   ARC458A4




6                                                                                  Humidifying Air Purifier
SiBE81-909                                                                                                       Specifications



4. Specifications
4.1           Specifications

                                                                         MCK75JVM-K
 Model
                                          Air purifying operation                              Humidifying operation
 Type                                                               Humidifying air purifier
 Color        1                                                              Black
 Power supply                                                1φ, 220-240/220-230V, 50/60Hz
 Running current
                               A      0.71 / 0.31 / 0.19 / 0.12 / 0.09                   0.72 / 0.32 / 0.19 / 0.13 / 0.11
 (HH/H/M/L/LL)
 Power consumption
                               W            81 / 35 / 18 / 11 / 8                              84 / 37 / 20 / 13 / 12
 (HH/H/M/L/LL)
 Humidification
                              mL/h                   —                                    600 / 470 / 370 / 290 / 240
 (HH/H/M/L/LL) 2
 Water tank capacity           L                                              4.0
 Operating sound         3
                              dB(A)        50 / 43 / 36 / 26 / 17                              50 / 43 / 36 / 26 / 23
 (HH/H/M/L/LL)
 Airflow rate
                              m3/h       450 / 330 / 240 / 150 / 60                       450 / 330 / 240 / 150 / 120
 (HH/H/M/L/LL)
                  Type                            Multi Blade Fan (Sirocco fan with shroud assembly)
 Fan
                  Running method                                          Direct drive
 Dust collecting method                            Plasma ionizer + Electrostatic dust collection filter
 Deodorizing method                   Flash streamer + Titanium apatite photocatalytic filter + Deodorizing catalyst
 Air filter                                                  Polypropylene net with catechin
 Bacteria filtering method                                                    —
                                          Dust sensor lamp: 3 stages
                                          Odor sensor lamp: 3 stages
                                          Humidify indicator lamp: 3 stages
                                          Humidify ON/OFF
                                          Airflow rate: Automatic/LL/L/M/H, Turbo mode (HH), Anti-pollen mode
                                          Humidify setting: LOW/STD/HIGH/CONT
 Sign                                     OFF timer: 1/4/8hrs
                                          Cleaning Sign: lonization/Streamer
                                          Replacement Sign: Humidifying filter, Air-purifying filter
                                          Water supply lamp
                                          Child proof lock lamp
                                          Regeneration lamp (8hrs)
                                          Check lamp
 Dimensions
                              mm                                       590 x 395 x 268
 (H x W x D)
 Package dimensions
                              mm                                       653 x 445 x 318
 (H x W x D)
 Product weight                kg                                            11.0
 Gross weight                  kg                                            15.0
                                                                     Safety switch
 Safety device
                                                   (Operation stops when the front panel is opened.)
 Power cord                    m                                              2.0
                                                 Operation manual (1), Wireless remote controller (1),
 Standard accessories
                                             Photocatalytic pleated filter (1+6), Deodorization cartridge (1)    4
 Drawing number                                                           3D063375


Humidifying Air Purifier                                                                                                     7
Specifications                                                                                                    SiBE81-909


NOTE:
 1. Panel color : Silver (General) / Bordeaux, Black Optional accessory (for Russia only).
 2. Humidification amount changes in accordance with indoor and outdoor temperature and humidity.
    Measurement condition : 20°C (temperature), 30% (humidity) (JEM1426)
 3. Operating sound levels are the average of values measured at 1m away from the front, left, right, and top of the unit.
    (This equal to the value in an anechoic chamber.)
 4. The refreshing time of the deodorization cartridge is 8 hours.




8                                                                                                      Humidifying Air Purifier
SiBE81-909                                                                                                                                                                                         Specifications


4.2       Dimension

   MCK75JVM-K
        · Required installation space (If installed on the floor)
                                                Air outlet grille
                                                                                                                                                            Signal Transmitter
                                                                                                                                                                                                 11




                                                                100 or more
                                                                                                                                                                                                  8

                                                                                      ON / OFF button




                                                                                                                                                                       90
          500 or more                                         500 or more                                                                                                          52




                                                                                                        1000 or more
                                                                                                                                                                  · Dimension of remote controller
             1000 or more




                                                                                                                                                                                 (ARC458A4)


       Dust sensor                                           Odor sensor Handles
                                                                                                                             Direction of a blow
                                                                                    Receiver


                                                                                                                                          Streamer pocket
                                                                              590




                                                                                                                                                                                              Power supply cord
                                                                                                                                                                                    Plug type    : C- Type
                                                                                                                                                                                    Type of Cordage : H05VVH2-F
                                                                                                                                                                                    Cross Sectional Area : 0.75mm2
                                                                                                                                                                                    No. of conductors      :2
                                                                                                                                                                                    Length outside machine : 2000±50
                                                                              2




                        (4)         395                         (4)                                                    268                 13 (40.5)
                                                                    Air inlet grille                                                    Manufacturer's                                                       3D062756
                                                                                                                                        Label




Humidifying Air Purifier                                                                                                                                                                                                9
Specifications                                                                                                                                                                                                                                         SiBE81-909


4.3                 Wiring Diagram

     MCK75JVM-K

                                                                                                                                                                                                                                   Note: 1. S, CN SHOWS A CONNECTOR.
                                                                                                                                                                                                                                         2. SYMBOLS SHOWS AS FOLLOWS
      A1P H37P H36P                                                                                                                                               H38P H39P
                                                                                                                                                                                                A5P                                         RED : RED   BLK : BLACK
            H30P H31P H24P H44P                                 H29P H35P H28P H34P H27P H33P H26P H32P H25P H43P H42P H41P H40P                                        H23P                                                                WHT : WHITE YLW : YELLOW
                                                                                                                                                                                                 CN1
                                                                                                                                          S400                              ODOR                           HUMIDITY
                                                                                                                                                                           SENSOR                                                           GRN : GREEN BLU : BLUE
                                                                                                                                                                                                     RTH SENSOR                             PNK : PINK  BRN : BROWN
                                                                                                                                               20                                           4                                                           ORG : ORANGE
      A2P                                                                                H12P
                                                                                                                                                                H10         S4
                                                                                         H11P                                             S129                                                      A6P
                         H22P             H21P            H17P                           H10P                                             H1P        BS2                               Z2C            CN2
                                                                                                                                                                                                6
                    S3                                                                   H9P                                                                            S1                            DUST SENSOR
                                                                                                                          INCLINATION
                         H20P             H19P                                                                              SENSOR                                   S128              N=3
                         BS8              BS7              BS6               BS5          BS4                  BS3                                   BS1
                                                                                                                                                                           16
                                                                                                                                                                                                                            S1C
                                                    A3P                                                                                                                                                    S114
                         A7P                                                                        POWER SUPPLY                                                     S118
                                                                                                                                                                                                                            S2C
                  3       CN3                                                                       DC 340V OUT                                                                                            S115
                                     SIGNAL                                                         DC 15V OUT
                                    RECEIVER                                                        DC 12V OUT AC IN                                                                                                        A4P
                                                                                                    DC 5V OUT
                                                                                                    GND                             F1U                                                                                                        GRN
                                                                                                                                                                                                                                                     STREAMER PART
                                                                                                                                                                                                                                               WHT
                                                                                                                                                                                                                       10                      GRN
                                                                                                                                                                                                         S111                     S401               IONIZATION PART
                                                                                  S113              S116                                          S108                                                                                         RED
                                                                                                                 S102
                WIRELESS
                REMOTE                                                     S1L                                           5                               S1S
                                                                                                                                                    Z1C 4   3                         X1P
                CONTROLLER                                                                                                                                                                        POWER SUPPLY PLUG
                                                                                                      M M1                   MS   M1F                       2       1
                                                                                                      ~                      3~                                                                 220-240V/220-230V 50/60Hz
                                                                                                                                                    N=2
  A1P    PRINTED CIRCUIT BOARD (FOR DISPLAY) H20P                          LED (HUMIDIFYING FILTER REPLACEMENT : ORANGE) H37P   LED (DUST SIGN : GREEN/RED)                     S1S   SAFETY SWITCH
  A2P    PRINTED CIRCUIT BOARD (FOR OPERATION) H21P                        LED (CLEANING OF UNIT2 : ORANGE)              H38P   LED (ODOR SIGN : GREEN/RED)                     S1C   LIMIT SWITCH (REGENERATION OF CARTRIDGE)
  A3P    PRINTED CIRCUIT BOARD (FOR POWER SUPPLY) H22P                     LED (CLEANING OF UNIT1 : ORANGE)              H39P   LED (ODOR SIGN : GREEN/RED)                     S2C   LIMIT SWITCH (TRAY)
  A4P    PRINTED CIRCUIT BOARD (FOR HIGH VOLTAGE POWER SUPPLY UNIT) H23P   LED (ODOR SIGN : GREEN/RED)                   H40P   LED (FAN SET POLLEN : GREEN)                    S1L   FLOAT SWITCH
  A5P    PRINTED CIRCUIT BOARD (HUMIDITY SENSOR) H24P                      LED (REGENERATION OF CARTRIDGE : ORANGE) H41P        LED (FAN SET TURBO : GREEN)                     X1P   POWER SUPPLY PLUG
  A6P    DUST SENSOR                                                H25P   LED (FAN SET LOW : GREEN)                     H42P   LED (FAN SET HIGH : GREEN)                      Z1C   FERRITE CORE
  A7P    PRINTED CIRCUIT BOARD (FOR SIGNAL RECEIVER) H26P                  LED (FAN AUTO OPERATION : YELLOW) H43P               LED (FAN SET STANDARD : GREEN)                  Z2C   FERRITE CORE
  M1F    DC FAN MOTOR                                               H27P   LED (HUMIDITY INDICATOR APPROX 50% : GREEN) F1U      FUSE (250V, 5A)
  M1     AC INDUCTOR MOTOR                                          H28P   LED (CUT OFF TIMER (8 HOUR) : YELLOW) H1O            BUZZER (RECEIVING SIGN)
  RTH    TEMPERATURE SENSOR                                         H29P   LED (CUT OFF TIMER (1 HOUR) : YELLOW) BS1            ON/OFF SWITCH
  H1P    LED (HUMIDIFY ON/OFF : ORANGE)                             H30P   LED (DUST SIGN : GREEN/RED)                   BS2    HUMIDIFY ON/OFF SWITCH
  H9P    LED (HUM SET LOW : GREEN)                                  H31P   LED (CHILD PROOF LOCK : ORANGE)               BS3    FAN SETTING SWITCH
  H10P   LED (HUM SET STD : GREEN)                                  H32P   LED (FAN SET QUIET : GREEN)                   BS4    HUMIDIFY SETTING SWITCH
  H11P   LED (HUM SET HIGH : GREEN)                                 H33P   LED (HUMIDITY INDICATOR 60% OR MORE : GREEN) BS5     OFF TIMER SWITCH
  H12P   LED (HUM SET CONT : GREEN)                                 H34P   LED (HUMIDITY INDICATOR 40% OR LESS : GREEN) BS6     BRIGHTNESS AJUSTMENT SWITCH
  H17P   LED (EMPTY : ORANGE)                                       H35P   LED (CUT OFF TIMER (4 HOUR) : YELLOW) BS7            RESET SWITCH (AIR-PURIFYING FILTER REPLACEMENT)
  H19P   LED (AIR-PURIFYING FILTER REPLACEMENT : ORANGE) H36P              LED (DUST SIGN : GREEN/RED)                   BS8    RESET SWITCH (HUMIDIFYING FILTER REPLACEMENT)
                                                                                                                                                                                                                                                           3D062755




10                                                                                                                                                                                                                                        Humidifying Air Purifier
SiBE81-909                                                                                   Specifications


4.4      Packaging Drawing




                             Deodrizing cartridge pack

               Wireless remote controller ASSY

                                                                         Power supply code
                       Pleats filter




                                                                VIEW A

         Accesory bag ASSY
                             A




                                                         Body


                                                     Product cover




                                                                                              C : 2P241869A




Humidifying Air Purifier                                                                                      11
Operation Manual                       SiBE81-909



5. Operation Manual
5.1    Safety Precautions




12                          Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                13
Operation Manual              SiBE81-909




14                 Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                15
Operation Manual                                     SiBE81-909


5.2    Names and Operation of Each Part




16                                        Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                17
Operation Manual              SiBE81-909




18                 Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                19
Operation Manual              SiBE81-909




20                 Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                21
Operation Manual                                            SiBE81-909


5.3    Sensitivity Settings of the Dust Sensor




22                                               Humidifying Air Purifier
SiBE81-909                 Operation Manual


5.4      Installation




Humidifying Air Purifier                23
Operation Manual                                     SiBE81-909


5.5    Preparation of Remote Controller




24                                        Humidifying Air Purifier
SiBE81-909                   Operation Manual


5.6      Attach the Filter




Humidifying Air Purifier                  25
Operation Manual                            SiBE81-909


5.7    Water Tank Preparations




26                               Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                27
Operation Manual                            SiBE81-909


5.8    Air Purifying Operation




28                               Humidifying Air Purifier
SiBE81-909                                       Operation Manual


5.9      Humidify and Air Purifying Operations




Humidifying Air Purifier                                      29
Operation Manual                                        SiBE81-909


5.10 How to Operate with Remote Controller




30                                           Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                31
Operation Manual                                                  SiBE81-909


5.11 How to Use the Recyclable Deodorizing Cartridge




32                                                     Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                33
Operation Manual                                       SiBE81-909


5.12 Quick Reference Table of Maintenance




34                                          Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                35
Operation Manual                    SiBE81-909


5.13 Care and Cleaning




36                       Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                37
Operation Manual              SiBE81-909




38                 Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                39
Operation Manual              SiBE81-909




40                 Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                41
Operation Manual              SiBE81-909




42                 Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                43
Operation Manual              SiBE81-909




44                 Humidifying Air Purifier
SiBE81-909                 Operation Manual




Humidifying Air Purifier                45
Operation Manual              SiBE81-909




46                 Humidifying Air Purifier
SiBE81-909                 Operation Manual




                             3P234570-1




Humidifying Air Purifier                  47
Optional Accessories                                                                                                                         SiBE81-909



6. Optional Accessories
6.1     Dimensions
6.1.1 Pleated Filter

     KAC998A4E                                                                             Specifications
                                                                                                     Model
                                                                                      Item                               KAC998A4E
                                                                                      Material                  Non-woven fabric (electrostatic)
                                                                                      Quantity                               7

                                                                                     Notes: 1. Replacement guideline: Every year (for about 7
                                                                                               years in total)
                                                                                            2. Appearance color: White (front), blue (back)
                 305

                       67




                                                                           67
                       26




                                                                           11




                                26 pleats ± 1pleat
                                                                1pleat
                                                                          14




                            Extend pleats in using
                                                                                                                                               C:3JHB13523


6.1.2 Humidifying Filter

     KNME998A4E                                                                            Specifications
                                                                                                     Model
                                                                                      Item                              KNME998A4E
                                                                                      Material                 Non-woven fabric (Rayon / PET)
                                                                                      Quantity                               1

                                                                                     Notes: 1. Replacement guideline: Approx. 2 years
                                                                                            2. Appearance color: Orange
                                                                                            3. Every 2 weeks, soak in water or warm water with
                                                                                               neutral detergent for 30~60 minutes. Rinse well
                                                                                               afterwards.
                                                                     40
                                                                    φ2




                                                                                φ20 hole
                                                                                    20




                                              47 pleats ± 1 pleat




                                                                                                                                               C:3JHB13522



48                                                                                                                       Humidifying Air Purifier
SiBE81-909                                                                                          Optional Accessories


6.1.3 Front Panel (for Russia)

    BCK75J-BD
                                                                                 Specifications
                                                                                            Model
                                                                                                    BCK75J-BD
                                                                               Color and            Bordeaux: 1
                      FRONT PANEL (OPTION)                                     Quantity             Black: 1



                                             Bordeaux or Black         Black




                                                                       502.5
                              (4)               395              (4)                       46.5




                                                                                                                  C:3D063742




Humidifying Air Purifier                                                                                                       49
Troubleshooting                                                                            SiBE81-909



7. Troubleshooting
7.1      Basic Inspection




(1) Is the connector for the PCB plugged
    in? Or is there any poor connection?




(2) Is the wire harness broken?




    It is not malfunction.
.




                                              Lighting
                                              UNIT1 Plasma ionizer
                                              UNIT2 Streamer unit
                                              Clean as above.




                   Lighting or Flash
                   Replace the humidifying filter or the air-purifying filter
                   (pleated filter). Then, press and hold the RESET button
                   for 2 seconds.




50                                                                              Humidifying Air Purifier
SiBE81-909                              Troubleshooting




                           Check lamp




Humidifying Air Purifier                            51
Troubleshooting                      SiBE81-909


 It may be malfunction.




52                        Humidifying Air Purifier
SiBE81-909                                   Troubleshooting


7.2      Check Before Requesting Servicing




Humidifying Air Purifier                                 53
Troubleshooting              SiBE81-909




54                Humidifying Air Purifier
SiBE81-909                 Troubleshooting




Humidifying Air Purifier               55
Troubleshooting                                SiBE81-909


7.3    Frequently Asked Questions




56                                  Humidifying Air Purifier
SiBE81-909                                                                                                                  Troubleshooting


7.4      Troubleshooting
7.4.1 Equipment does not operate, or operation lamps does not light.
                            Be sure to turn off power switch before connect or disconnect connector,
                 Caution    or parts damage may be occurred.


 1    Models Covered                        5     Troubleshooting
 MCK75JVM-K                                                                 Diagnosis                                        Remedy


                                                Is the power cord plugged in?      No                                    Plug in the power
                                                    Or is the breaker "ON"?                                              cord.
                                                                                                                         Set the breaker to
                                                               Yes                                                       “ON”.
 2    Method of Mal-                                Is the panel closed            No
                                                                                                                         Close the upper
                                                           tirmly?
      function Detection                                                                                                 part of the panel
                                                               Yes                                                       firmly.

                                                    Is the water supply            Yes
                                                                                                                         Go to “7.2.2 The
                                                       lamp blinking?
                                                                                                                         water supply lamp
                                                               No                                                        blinks”

                                                                                   No                              Yes   Wait for power res-
                                               Do other appliances operate?              Is there power failure?
                                                                                                                         toration.

 3    Malfunction Deci-
                                                               Yes                                   No                  When unspecified
                                                                                                                         voltage is applied,
                                                                                                                   No    replace the power
      sion conditions                                                                    Is 220-240V supplied?
                                                                                                                         supply PCB.
                                                                                                     Yes                 (The varistor or the
                                                                                                                         fuse may be dam-
                                                                                                                         aged.)
                                                                                   No                                    Go to Check1 on
                                               Is rated voltage within ±10%?
                                                                                                                         P. 64.
                                                               Yes                                                       Contact power
                                                                                                                         company.
                                               Remove the front panel.
 4    Supposed Causes
 • The unit is not turned on.
 • Unspecified voltage is used.                 Is the protrusion on the rear      Yes
                                                                                                                         Replace the front
 • The front panel is broken. (The                    panel damaged?                                                     panel.
   protrusion on the front panel is                                                                                      *The protrusion on the
   broken.)                                                    No                                                        front panel is broken.
 • The power supply PCB is
                                             Front panel switch operation check
   defective.
                                            Press the front panel switch with a
   (The front panel switch is
                                            thin stick, then press ON/OFF switch
   defective.)                              after 5 seconds.
 • The operation PCB is
                                                                                                                                Protrusion
   defective.
                                                                                                                           Rear side
                                                   Does the front panel            Yes
                                                   operation lamp light?
                                                                                                                         Replace the front
                                                                                                                         panel. (The front
                                                               No                                                        panel switch may
                                                                                                                         not work due to
                                                                                                                         deformity).
                                                                                                                         Replace the power
                                                                                                                         supply PCB or the
                                                                                                                         operation PCB.
                                                                                                                         Go to Check1 on
                                                                                                                         P. 64.




Humidifying Air Purifier                                                                                                                      57
Troubleshooting                                                                                                          SiBE81-909


7.4.2 The water supply lamp blinks.
                                Be sure to turn off power switch before connect or disconnect connector,
                      Caution   or parts damage may be occurred.


 1      Models Covered                          5    Troubleshooting
 MCK75JVM-K                                                              Diagnosis                               Remedy


                                                                        Is the humidifying        Yes       Set the humidifying
                                                                          tray removed?                     tray.

                                                                                   No


 2      Method of Mal-                                            Remove the front panel and
                                                                  the water tank, and then
                                                                  remove the humidifying tray.
        function Detection

                                                                         Is the protrusion at     Yes       Replace the humid-
                                                                    left end of the humidifying             ifying tray.
                                                                            tray damaged?

                                                                                   No




                                                                                                            Protrusion
 3      Malfunction Deci-                                               Is the limit switch
                                                                    connector connected to the
                                                                                                  No        Connect the limit
                                                                       power supply PCB?                    switch connector.
        sion conditions                                                                                     [S115]
                                                                                   Yes

                                                                                                  Yes       Replace the har-
                                                                      Is the harness broken?
                                                                                                            ness.
                                                                                   No
                                                                                                            Replace the limit
                                                                                                            switch.
 4      Supposed Causes                                                                                     [S2C]

 • The humidifying tray is removed or
     not installed.
 • The humidifying tray is deformed
     or broken.
 • The connector is improperly con-
     nected.
 • The limit switch harness is broken.
 • The limit switch is defective.




58                                                                                                         Humidifying Air Purifier
SiBE81-909                                                                                                  Troubleshooting


7.4.3 The odor / dust sensor lamp keeps lighting red.
                           Be sure to turn off power switch before connect or disconnect connector,
                 Caution   or parts damage may be occurred.


 1    Models Covered                       5    Troubleshooting
 MCK75JVM-K                                                         Diagnosis                                Remedy
                                                       <When the odor sensor is lighting red:>
                                                             Check humidity of the
                                                             installation environment.



 2    Method of Mal-                                               Is the humidity 80%
                                                                         or lower?
                                                                                                   No
                                                                                                         This is not a failure.
                                                                                                         The odor sensor
      function Detection                                                      Yes                        detects moisture in
                                                                                                         the air.
                                                             Install the unit in                         • Install the unit in
                                                             another room or corridor.                     other place.
                                                                                                         • Reset the power
                                                                                                           supply.
                                                                   Does the lamp keep              Yes
                                                                                                         Replace the dis-
                                                                      lighting red?
                                                                                                         play PCB.
                                                                              No                         Go to Check1 on
 3    Malfunction Deci-                                                                                  P. 64.
                                                                                                         This is not a failure.
      sion conditions                                                                                    • When the room is
                                                                                                           too large or open,
                                                                                                           the sensor is
                                                                                                           always activated
                                                       <When the dust sensor is lighting red:>
                                                                                                           due to insufficient
                                                                                                           capacity.
                                                             Clean the air inlet port and the
                                                             peripheral area of the dust sensor.
                                                             Install the unit in another place.
 4    Supposed Causes
 • Wrong diagnosis
   (Red lighting of the odor/dust sen-                              Is the dust sensor             Yes
                                                                                                         This is not a failure.
   sor during detecting dust or mois-                                 lamp changed?
   ture in the air was decided as
                                                                              No
   failure.)
 • The sensor is defective.
   (The display PCB is defective.)                                   Is the connector              No
                                                                    of the dust sensor                   Connect the con-
 • The dust sensor is defective.
                                                                        connected?                       nector.
                                                                              Yes                        [S1, CN2]


                                                                                                   Yes
                                                                  Is the harness broken?                 Replace the har-
                                                                                                         ness.
                                                                              No
                                                                                                         Replace the dust
                                                                                                         sensor the opera-
                                                                                                         tion PCB.
                                                                                                         Go to Check1 on
                                                                                                         P. 64.




Humidifying Air Purifier                                                                                                      59
Troubleshooting                                                                                                     SiBE81-909


7.4.4 DC fan locks.
                              Be sure to turn off power switch before connect or disconnect connector,
                  Caution     or parts damage may be occurred.


 1      Models Covered                        5    Troubleshooting
 MCK75JVM-K                                                           Diagnosis                                Remedy

                                                               All 4 airflow rate indicators
                                                               blink simultaneously.

                                                               Disconnect the power
 2      Method of Mal-                                         supply plug once and wait
                                                               for 3 seconds. And then,                   NOTE: Turn off the
                                                               reconnect the power                        power before
       function Detection                                      supply plug.
                                                                                                          unplugging the con-
 Abnormality of the fan motor is                                                                          nector. If the con-
                                                               Retry to operate with the
 detected by revolutions with the Hall                         ON/OFF switch.                             nector is unplugged
 IC while the fan motor is running.                                                                       with the unit turned
                                                                                                          on, the fan motor
                                                               Airflow rate indicators
                                                               blink then go OFF.                         may be damaged.
                                                                                                          (Turn off the power
                                                                                                          before plugging in
                                                                                                          connector as well.)
                                                                     Is there any foreign      Yes
                                                                       object in the fan?                 Remove the for-
                                                                                                          eign objects and
 3      Malfunction Deci-                                                       No                        restart operation.

                                                                                               Yes
       sion conditions                                            Is the fan motor connector
                                                                        disconnected?
                                                                                                          Connect.
                                                                                                          [S102]
 When the fan motor is not revved                                               No
 up.                                                                                                      Replace the fan
                                                                                                          motor.
                                                                                                          • When the indica-
                                                                                                            tors blink after
                                                                                                            restarting,
                                                                                                            replace the power
                                                                                                            supply PCB or
                                                                                                            the operation
                                                                                                            PCB.
                                                                                                          Go to Check1 on
                                                                                                          P. 64.
 4      Supposed Causes
 • The fan motor is defective.
 • The power supply PCB or opera-
     tion PCB is defective.
 • Foreign objects in the fan.
 • The connector is disconnected.




60                                                                                                       Humidifying Air Purifier
SiBE81-909                                                                                               Troubleshooting


7.4.5 The odor / dust / humidity sensor lamp does not light.
                           Be sure to turn off power switch before connect or disconnect connector,
                 Caution   or parts damage may be occurred.



 1    Models Covered                       5    Troubleshooting
 MCK75JVM-K                                                        Diagnosis                              Remedy



                                                                    If the brightness
                                                                                           Yes        This is not a failure.
                                                             adjustment button is pressed,
                                                                   is the lamp turned
                                                                           on?

                                                                             No
 2    Method of Mal-
      function Detection                                             Is the flat cable
                                                                                           No
                                                                 linking the display PCB
                                                                 and the operation PCB
                                                                                                      Connect the flat
                                                                       connected?                     cable.
                                                                                                      [S129, S400]
                                                                             Yes
                                                                                                      Replace the dis-
 3    Malfunction Deci-                                                                               play PCB or the
                                                                                                      operation PCB.
      sion conditions                                                                                 Go to Check1 on
                                                                                                      P. 64.




 4    Supposed Causes
 • The flat cable is improperly con-
   nected.
 • The display PCB is defective.
 • The operation PCB is defective.




Humidifying Air Purifier                                                                                                   61
Troubleshooting                                                                                                                SiBE81-909


7.4.6 Humidity is not increased, or the humidity sensor lamp is not changed.
                            Be sure to turn off power switch before connect or disconnect connector,
                Caution     or parts damage may be occurred.



 1      Models Covered                      5    Troubleshooting
 MCK75JVM-K                                                                Diagnosis                                      Remedy


                                                        Do the 4                    Check humidity in the
                                                                              No    installation environment.
                                                humidity switching lamps            Move the unit to other
                                                    simultaneously                  humidity environment
                                                          blink?                    such as another room.

                                                              Yes
                                                                                         Is humidity in the   Yes
 2      Method of Mal-                                                                   display changed?
                                                                                                                     This is not a failure.

                                                                                                  No                 Replace the humid-
        function Detection                                                                                           ity sensor PCB or
                                                                                                                     the operation PCB.
                                                                                                                     Go to Check1 on
                                                                                                                     P. 64.
                                                Is the connector of the       No
                                                                                                                     Connect.
                                                 humidity sensor PCB
                                                      connected?                                                     [S4] [CN1]


 3      Malfunction Deci-                                     Yes


        sion conditions                           Is the harness broken?
                                                                              Yes
                                                                                                                     Replace the har-
                                                                                                                     ness.
                                                             No
                                                                                                                     Replace the humid-
                                                                                                                     ity sensor PCB, the
                                                                                                                     display PCB, or the
                                                                                                                     operation PCB.

 4      Supposed Causes                                                                                              Go to Check1 on
                                                                                                                     P. 64.
 • The humidity sensor PCB is defec-
     tive.
 • The display PCB is defective.
 • The operation PCB is defective.
 • The connector is improperly con-
     nected.
 • The harness is broken.




62                                                                                                                  Humidifying Air Purifier
SiBE81-909                                                                                               Troubleshooting


7.4.7 The power supply PCB or the operation PCB is at fault.
                           Be sure to turn off power switch before connect or disconnect connector,
                 Caution   or parts damage may be occurred.



 1    Models Covered                       5    Troubleshooting
 MCK75JVM-K                                                        Diagnosis                              Remedy

                                                              The 3 OFF timer lamps
                                                              simultaneously blink.


                                                              Check the connector
                                                              for connection (S108).


 2    Method of Mal-                                               Is the connector     Yes           Replace the power
                                                                 properly connected?                  supply PCB.
      function Detection
                                                                          No                          Go to Check1 on
 Abnormality of the zero cross from                                                                   P. 64.
 the power supply is detected.                                Correct the connection.



                                                                Do the lamps above      Yes

 3    Malfunction Deci-                                             blink again?                      Replace the opera-
                                                                                                      tion PCB.
                                                                          No
      sion conditions                                                                                 Go to Check1 on
                                                                        OK                            P. 64.
 When the zero cross cannot contin-
 uously be detected for about 10 sec-
 onds


 4    Supposed Causes
 • The connector is improperly con-
   nected.
 • The power supply PCB is defec-
   tive.
 • The operation PCB is defective.




Humidifying Air Purifier                                                                                                63
Troubleshooting                                                                                                                       SiBE81-909


7.5      Check
7.5.1 Checking the connection when the PCB is replaced.

Check1

                  Perform the following checking procedure when replacing the PCB.
                  (1) Procedure
                        Pressing [ON/OFF] button and [Humidify ON/OFF] button simultaneously,
                        turn on the power. → The buzzer sounds and all lamps light.
                        After checking the buzzer sound, press [ON/OFF] button once.
                         → The lamps corresponding to the PCB version light.
                        Press [Humidify ON/OFF] button once.
                        Press [Fan setting] button once.→ Check the sensor.
                         Normal The buzzer sounds and all lamps light.
                         Error   Refer to the 4 lamps below.
                                                                        • When the unit 1 lamp blinks:
                                                                                   The dust sensor is at fault or
                                                                                   improperly connected.
                                                                        • When the unit 2 lamp blinks:
                                                                                   The odor sensor is at fault.
                                                                        • When the humidifying filter lamp blinks:
                                                                                   The humidifying sensor is at fault or
                                                                                   improperly connected.
                                                                        • When the air-purifying filter lamp blinks:
                            Use the 4 lamps for checking.                          The room temperature thermistor is
                                                                                   at fault or improperly connected.
                           Reset the power supply to resume the normal mode.
                  (2)   Procedure (Wiring check mode)
                        Insert the power supply plug into the outlet.
                        Press [OFF TIMER] button within 2 seconds.
                          Normal The buzzer sounds and all lamps light.
                         Error   (when connection is improper):
                        • When the unit 1 lamp lights: The wiring of the dust correction HVU is improperly connected.
                        • When the unit 2 lamp lights: The wiring of the streamer HVU is improperly connected.
                        • When the unit 1 and unit 2 lamps light simultaneously: The wirings of the dust correction HVU
                          and the streamer HVU are improperly connected.
                        Reset the power supply to resume the normal mode.




64                                                                                                                         Humidifying Air Purifier
Specifications, designs and other content appearing in this brochure are current as of December 2008 but subject to change without notice.
                                                                                                                                             SiBE81-909
                                                                                                                                             Printed in Japan 12/2008 B AK

				
DOCUMENT INFO
Shared By:
Categories:
Stats:
views:47
posted:1/27/2011
language:English
pages:66