					550, 700 & 850 De Luxe
   Gas Convector



  INSTALLATION
   & OPERATING
 INSTRUCTIONS
                                                                               CONTENTS
550, 700 & 850 GAS CONVECTOR
INSTALLATION & OPERATING INSTRUCTIONS

PLEASE READ THESE CAREFULLY BEFORE STARTING WORK
The fitter must read ALL parts below. Customers are strongly recommended
to read Parts 1 - 5, 8, 11 and 13 - 23 of these instructions.


INDEX
Technical Data                                                        2
Installation Instructions
    1     General                                                     3
    2     Gas Specifications                                          4
    3     Regulations                                                 4
    4     Deviation from Instructions                                 4
    5     Ventilation                                                 5
    6     Chimney                                                     5
    7     Preparatory Building Work                                   6
    8     Fitting the Jetmaster Convector Box                         6
    9     Gas Cylinders, Pipe Runs and Sizes                          7
    10 Fitting the Gas Burner                                         8
    11 Positioning the Coals: 550, 700 & 850 Gas Convector           11
    12 Commissioning the Fire                                        14
Users Instructions
    13 General                                                       15
    14 Lighting the Fire: 550 & 700 Gas Convector                    16
    15 Lighting the Fire: 850 Gas Convector                          17
    16 Cleaning Instructions                                         18
Servicing Instructions
    17 General                                                       19
    18 Servicing Procedure                                           19
    19 Registering the Warranty                                      19
    20 Repairs under Warranty                                        20
    21 Maintaining the Gas Grate                                     20
    22 Gas Fumes
Warranty                                                             21




 INSTALLATION & OPERATING INSTRUCTIONS                                     1
INSTALLATION AND OPERATING INSTRUCTIONS:
                     550, 700 & 850 DE LUXE   Technical Data

                                              Gas Inlet Connection: 5/16" (8 mm) O.D. tube with olive fittings into a test
                                                                    point on the right-hand side of the Gas Convector.
                                              Regular LPG:                2,75 Kpa inlet pressure.

                                              Gas Control:                BM 733 model for both the 550 and 700 burner.
                                                                          Baby Sit Manual Control Valve fitted to the 850 burner.
                                                                          These gas controls are located centrally underneath the
                                                                          burner.
                                              Pilot Markings:             Oxygen depletion system fitted.
                                                                          LPG 9221 O.P. Controls.
                                              Pilot Turnoff Valve:        Integral with BM valve fitted to 550 and 700 burner.
                                                                          Integral with Baby Sit Manual Control Valve fitted to 850
                                                                          burner.
                                              Pressure Test Point:        5/16" (8mm) diameter nipple located on the inlet gas
                                                                          supply on the 550 and 700 burner.
                                                                          Test point on the Baby Sit Manual Control Valve on the
                                                                          850 burner.

                                              Gas Cylinder Size:          1 x 48kg bottle for 550-700 De Luxe Gas Convector.
                                                                          2 x 48kg bottle for 850 De Luxe Gas Convector.

                                                                          H                               J       I

                                                                                             D

                                                                                                          E

                                                                                                   C
                                                                                                                        G F


                                                              50           A                 50               B
                                                                         A + 50
                                                                                                       Note: The total width
                                                                                                       measurement including
                                                                                                       gather is A + 50


                                                     MODEL                                                        NOMINAL     ROUND
                                                     & SIZE                       mm                              FLUE SIZE EQUIVALENT
                                                        A       B   C     D     E       F         G        J           H   I     Ø
                                                       550     316 650   200   105     625       420      90          200 200   200
                                                       700     316 650   200   105     625       420      90          200 200   200
                                                       850     316 650   200   105     625       420      90          300 200   250


                 2                                                       INSTALLATION & OPERATING INSTRUCTIONS
550, 700 & 850 GAS CONVECTOR




                                                                                            550, 700 & 850 DE LUXE
                                                                                            INSTALLATION AND OPERATING INSTRUCTIONS:
INSTALLATION & OPERATING INSTRUCTIONS

1. General
This fire is intended for decorative           In some countries a non-combustible
purposes. Jetmaster Gas Grates are a fuel      hearth must be fitted in front of the fire
effect appliance intended for use in a         in accordance with National Regulations.
fireplace for the burning of solid fuel.
                                               The flue and/or chimney should be swept
This fire should be installed by a qualified   and tested in accordance with National
person.All relevant Codes and Regulations      Regulations to prove it has an adequate
laid down by the Gas Supply Authorities,       updraught which is sufficient to remove
Uniform Building Regulations and               all waste products of combustion before
requirements of local Municipal Authorities    the appliance is installed.
must be observed.
                                               The Gas connection must be in
Installation and use of this fire must be in   accordance with National Regulations
accordance with these instructions.            and be carried out by a qualified person.
Prior to installation, ensure that the local   The pilot light and flame sensing device
distribution conditions, (identification of    fitted to this fire is also an atmosphere
the type of gas and pressure) and the          sensing device. If for any reason any part
adjustment of the appliance are                of the pilot assembly is to be replaced
compatible.                                    ALL the assembly including the Pilot
                                               Burner, Thermocouple, Electrode and
The builders opening or fireplace opening      Injector must be exchanged complete
must be constructed of a non-combustible       for an original Manufacturers Pilot
material and must conform to any current       Assembly only. This Atmosphere Sensing
National Building Regulations.                 Device is not adjustable and must not be
                                               put out of action.
Combustible material should not be placed
within 0.5m radius of the fire.




 INSTALLATION & OPERATING INSTRUCTIONS                                                      3
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS

                                              2. Gas Specifications                         SABS 1539: 2001:
                                                                                            Appliances operating on LP Gas portable
                                              Jetmaster Gas Convector fireplaces are        and mobile appliances; safety aspects.
                                              designed to burn LP Gas only. For proper      SABS 087 Part 1: March 1999:
                                              performance, LP Gas fires are set either      Consumer LP Gas cylinder installation.
                                              for use on the Highveld or coastal regions.   SABS 087 Part 2: 1975:
                                              Check the markings on the outside of          Installation in mobile units and small
                                              the box in which the burner is delivered      non-permanent dwellings.
                                              to make sure you have the correct burner      SABS 087 Part V11: 1997:
                                              for where you stay. Do not take a Highveld    Retail outlets and similar gas filling sites
                                              burner to the coast or vice versa. Do         for small cylinders.
                                              not burn LP Gas on a Towns Gas burner         SABS 0400:
                                              or vice versa.                                Building Regulations.
                                                                                            SABS 1237: March 1990:
                                              3. Regulations                                Single stage low pressure regulators for
                                                                                            LP Gas.
                                              The installation of this Gas Convector        Fire Department:
                                              must be carried out fully in accordance       Safety guidelines.
                                              with these Installation Instructions, which   Building Inspectors for the
                                              comply with the current regulations of        planning of the installation.
                                              the Liquid Petroleum Gas Association of       Occupational Health and Safety
                                              Southern Africa (LPGAS Association).          Act 1993.
                                              The gas fitting connection and testing
                                              part of the installation must be carried      4. Deviations from Instructions
                                              out by a fitter registered with the
                                              SAQCCI.                                       Consult with Jetmaster PRIOR to
                                                                                            commencing installation, if any deviation
                                              The following documents have references       from these guidelines is being considered.
                                              which apply to the installation of this gas   Failure to do so may result in an illegal,
                                              fireplace, and the relevant clauses must      dangerous and uninsured fitting and will
                                              be applied:                                   invalidate your Jetmaster Warranty.




                4                                                           INSTALLATION & OPERATING INSTRUCTIONS
       550, 700 & 850 GAS CONVECTOR




                                                                                                                  550, 700 & 850 DE LUXE
                                                                                                                  INSTALLATION AND OPERATING INSTRUCTIONS:
       INSTALLATION & OPERATING INSTRUCTIONS

       5. Ventilation                                             6. Chimney
       Two ventilators to the outside must be                     The fireplace must be flued with the
       provided, one at just below ceiling level                  re c o m m e n d e d s i z e f l u e ( s e e
       and one at floor level. The existing                       specifications in front of this book on
       regulation states that : an air supply                     page 2) to the outside atmosphere not
       must be provided up to 150 cm2 for                         less than 4,6 metres high, and must be
       50 MJ input. This must be provided in                      cowled. The flue must be swept with a
       the form of two ventilators, one at                        brush before installation, and annually
       ceiling height and one at floor level.                     thereafter. DO NOT attach the gas fire
       Most properties have a ventilator at                       to a flue pipe of less than 200 mm
       ceiling height. The lower vent can be                      internal dimension.
       made quickly and cleanly using a core
       drill and fitting a sleeve and grids at
       each end and is best placed on the
       same wall as the fireplace, and close to
       the sides of the fire.
       NB: Larger vents are required if venting
       to well ventilated adjacent room (300
       cm2).                                                          Roof pitch less than 10˚
                                                                                   If 600 mm      If more than
                                                 At least                          or less        600 mm
                                                 600 mm
                                                   Chimney                                                 1m
                                                   (excl. cowl)




                   Roof pitch 10˚ or more




Chimney
(excl. cowl)
                                                 At least 1 m




                                            An opening or
                                            an adjacent
                                            structure                  Roof pitch less than 10˚
               If within 1,5 m

                                                      Chimney                                      At least 1 m
                                                      (excl. cowl)
                                                                                                  Uppermost
                                                                                                  roof level




         INSTALLATION & OPERATING INSTRUCTIONS                                                                    5
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS

                                              7. Preparatory Building Work                        and minimise heat loss to the building.
                                              (This can be carried out by a person who is
                                              not a registered LPGAS Association installer.)   8 Where offset in the flue is required,
                                                                                                 do not bend more than 45 degrees.
                                              1 When building the Jetmaster Gas                  Jetmaster fabricated bends are available.
                                                Convector into an existing fireplace,
                                                first remove all loose materials from          8. Fitting the Jetmaster
                                                the recess and measure the opening             Convector Box
                                                and recess to ensure that the Jetmaster        (This work can be carried out by a person
                                                Gas Convector will fit.                        who is not registered LPGAS Association
                                                                                               installer.)
                                              2 The recess must be large enough to
                                                provide a clearance of 15 to 20 mm             1 Slide the convector box into the recess.
                                                around the sides of the convector box            Ensure that no insulation or other
                                                and be in accordance with the                    material can fall and obstruct the fume
                                                dimensions given on page 2. Cut away             outlets. Ensure that a seal is formed
                                                or build up to achieve the desired               behind the frame of the convector box
                                                dimensions.                                      such that the only air which can reach
                                                                                                 the flue must travel in through the
                                              3 Where the recess is to be newly built,           front of the convector box and up
                                                form the recess to give a clearance              through the fume outlets.
                                                around the sides and back of the
                                                convector box of 15 to 20 mm to                2 Check that the flue outlets on top of
                                                accommodate the fibreglass insulation.           the convector box will not be
                                                                                                 obstructed.Where the convector box
                                              4 Where the sides or back of the recess            is to be installed beneath a particularly
                                                have to be built up, and the masonry             deep lintel supporting the chimney
                                                flue gather of the chimney is to be              breast and the flue outlets might be
                                                used, build up to the height of the              partially obscured, steps must be taken
                                                convector box only and then top with             to chamfer the underside of the lintel
                                                a sloping fillet or mortar.                      to 45 degrees to provide a smooth,
                                                                                                 unrestricted path for gases.
                                              5 If a metal flue gather with flue liners
                                                is to be used, they are available from         3 Check that the convection inlet channel
                                                Jetmaster or any authorised Jetmaster            at the base of the front of the
                                                dealer.                                          convector box is not restricted.
                                              6 Check that the hearth, or new plinth           4 If a gather has not been fitted, for
                                                where this is constructed, is level.             instance when the convector box has
                                                                                                 been installed in an existing fireplace
                                              7 Wrap the faces and sides of the fire             opening, mark and drill two securing
                                                with insulating material.This insulation         holes in the base of the convector box
                                                is not essential but it is recommended,          and the hearth below, and secure the
                                                particularly when fitting to and outside         convector box to prevent it from
                                                wall, since it will maximise heat                moving forward.
                                                retention in the convection chamber,




                6                                                             INSTALLATION & OPERATING INSTRUCTIONS
550, 700 & 850 GAS CONVECTOR




                                                                                            550, 700 & 850 DE LUXE
                                                                                            INSTALLATION AND OPERATING INSTRUCTIONS:
INSTALLATION & OPERATING INSTRUCTIONS

9. Gas Cylinder, Pipe Runs and                 LP pipe size: From cylinder and
Sizes                                          low pressure regulator (28
(This work must only be carried out by a       Mbar) to gas appliance:
person who is a registered LPGAS Association
installer.)                                    Copper tubing      8mm       15mm
                                               LP Gas             up to     to 30 m
1 Jetmaster LP Gas Convectors must             Convector          4m
  be operated off one or more 48 kg
  cylinders, depending on size of unit.        It is recommended by the LPGAS
  The cylinder(s) must be positioned           Association that any pipe run greater
  outside, as close as possible to the         than 9 metres is supplied under high
  appliance, and in any case not further       pressure and a low pressure regulator
  than 30 metres, the cylinders must be        is fitted within 4 metres of the fire.
  away from heat sources, electrical
  devices, drains, windows and                 3 Having positioned the 48 kg gas
  combustible materials, in accordance           cylinder in a fixed position, connect
  with SABS 087 Part 1: March 1999.              the regulator supplied to the flexible
  Cylinders must always stand in the             hose, and the male hose connector
  VERTICAL position and must be fixed            to the end of the copper tubing using
  so they cannot fall or be knocked              the compression fitting.These fittings
  over. For best performance, avoid cold         are supplied and should be used. If a
  areas and shade.Where the regulator            larger pipe is to be used then the
  or pipework is in a position which is          correct size of fittings will have to
  liable to be very cold in winter, it is        be obtained.
  advisable to lag them to prevent
  freezing up. It is always advisable to       4 Tighten the hose clamps and connect
  fix the regulator vertically rather than       the regulator to the cylinder. The
  horizontally. This will prevent any            regulator should be protected from
  condensation settling in the bottom            rain and fixed in the vertical position
  of the regulator which will freeze up          if possible alternatively angle the
  in the cold weather causing the Gas            regulator so that liquids cannot collect
  Convector to shut down.                        on the top causing rusting of internal
                                                 components and subsequent
2 Check the Jetmaster Pipe Sizing Chart          malfunctioning, i.e. the plastic cap
  below to choose the correct size of            should not face upwards.The air vent
  pipe for the Gas Convector size and            in the regulator must be pointing
  length of run. Although Jetmaster              downwards.
  supplies 4 metres of 8 mm copper
  tube with LP Gas Convectors, it is           5 Cover the end of the gas pipe to
  not necessarily of sufficient size if          prevent dirt getting into it and
  larger fire or longer than 4 metre run         damaging the valve, which will
  are to be fitted. Be sure to fit the right     invalidate the Warranty.
  size pipe. Do not run more than one
  gas fire off each supply, without first
  checking the fitter’s supply chart. Any
  queries please contact Jetmaster
  Technical Department.




 INSTALLATION & OPERATING INSTRUCTIONS                                                      7
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS

                                              6 If the pipe is to be laid in concrete,         has been made with larger than 8 mm
                                                or comes through a wall or chased              pipe, reduce it as close as possible to
                                                into a wall then the pipework must             the fire but not more than 4 metres
                                                be sleeved.This sleeve can be electrical       away, by using a reduction fitting. Now
                                                conduct or plastic pipe of a size larger       that the pipe work is within the
                                                than the outside diameter of the gas           convector box, secure the convector
                                                supply line. Place the gas pipe within         box by screwing it to the floor. (See
                                                the sleeve for protection.                     7.4 above)
                                              7 Run the gas pipe from the cylinder
                                                to the area of the fireplace allowing        2 Purge the pipe for dust and debris by
                                                a full metre of free pipe at the fireplace     running the gas for a few moments;
                                                end; pipe may be brought in through            failure to clear the dust or debris
                                                either side or the rear of the gas fire.       from the pipe will invalidate the
                                                                                               Warranty.
                                              8 All bends should be made with a pipe
                                                bender to prevent a restrictive kink         3 Remove the burner from its packing
                                                forming.                                       and examine the connections,
                                                                                               checking that none are loose.
                                              10. Fitting the Gas Burner
                                                                                             4 With the burner immediately in front
                                              (To ensure that the burner and coals are         of the convector box, place the unit
                                              not damaged, this work must be done after        in the frame supplied, run the gas pipe
                                              all building work has been completed. This       to the test point nipple, which for the
                                              work can only be carried out by a person         LP burner is positioned on the right-
                                              who is a registered LPGAS Association            hand side of the control valve when
                                              installer.)                                      viewed from the front. Place the
                                                                                               burner and frame in the convector
                                              1 Drill the side or the back of the              box and connect the pipe with the 8
                                                Jetmaster with a 10 or 12 mm drill             mm compression nut and olive making
                                                for the gas pipe entry point. Sleeve           sure that the connection is gas tight.
                                                the gas pipe with metal/plastic tubing         Do not strip it. Use of PTFE tape will
                                                where it is to pass through the wall           invalidate the Warranty as small pieces
                                                of the convector box to protect it. If         can enter the pipe and damage the
                                                the pipe run from the gas cylinder             valve.




                 8                                                           INSTALLATION & OPERATING INSTRUCTIONS
550, 700 & 850 GAS CONVECTOR




                                                                                              550, 700 & 850 DE LUXE
                                                                                              INSTALLATION AND OPERATING INSTRUCTIONS:
INSTALLATION & OPERATING INSTRUCTIONS

5 Having placed the burner tray in the          manometer or U gauge to the test
  frame supplied, push to the back of           nipple, making sure that the little screw
  the convector box, making sure that           on the test nipple is screwed tightly
  there is enough space between the             back in place when testing has finished.
  front edge of the burner tray and gas         The dynamic pressure should read 28
  front to allow the ceramics to sit in         MBar. If the pressure is lower, check
  the correct position. Adjustment on           the regulator on the cylinder and test
  the support legs on the burner may            all joints on the pipe-work and burner
  be required.                                  with an electronic gas leak detector
                                                or leak test fluid. Rectify and test again.
6 Open the gas supply and test for leaks
  as far as the valve, attaching a         7 Fit the gas front.




                                                    Inlet test point




                                    OUT    IN




 INSTALLATION & OPERATING INSTRUCTIONS                                                        9
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS


                                              Front Options




                10                                            INSTALLATION & OPERATING INSTRUCTIONS
550, 700 & 850 GAS CONVECTOR




                                                                                           550, 700 & 850 DE LUXE
                                                                                           INSTALLATION AND OPERATING INSTRUCTIONS:
INSTALLATION & OPERATING INSTRUCTIONS

11. Positioning the coals: 550, 700 & 850 Gas Convector
Warning
The fire must only be fitted with the ceramics supplied. Do not add any extra coals
or logs.


                     Left hand        Right hand
                     front coal       front coal
        Pilot hole      piece            piece




                                                                             Flame strip
1    Position the front coal pieces as shown. The left hand front coal piece has a cut
     on its rear edge to clear the pilot hole. Ensure that the pilot hole and flame
     strip are not obstructed.


                        Back Board




                                                                             Flame strip
2    Position the back board centrally into the burner tray ensuring it is correctly
     seated and that the flame strip is not obstructed.



               Left hand coal piece

                           Right hand coal piece




3    Fit the left hand and right hand coal pieces either side of the back board into
     the burner tray. They should be fully fitted into the burner tray and touch the
     rear of the front coal pieces.


    INSTALLATION & OPERATING INSTRUCTIONS                                                  11
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS



                                                                         First row of coals




                                              4           Position a first row of coals at the front (5 on the 550GC, 6 on the 700GC
                                                          and 9 on the 850GC).They should bridge the gap between the front coal pieces
                                                          and the front row of pyramids on the back board. Leave a gap of approximately
                                                          5 - 10mm between each coal. Do not attempt to force any coals down into
                                                          the gap between the front coal pieces and the back board.



                                                                         Second row of coals




                                                  5        Position a second row of coals (4 on the 550GC, 5 on the 700GC and 7 on the
                                                           850GC). These should rest on the pyramids on the back board and touch the
                                                           front row of coals. Leave a gap of approximately 5 - 10mm between these coals.
                                                           Do not attempt to force the coals down between the pyramids.




                                                                         Second row of coals




                                                      6     Position a third and final row of coals (5 on the 550GC, 6 on the 700GC and
                                                            8 on the 850GC). These should rest between the second row of coals and
                                                            the top of the back board. Leave a gap of approximately 5 - 10mm between
                                                            these coals. Do not attempt to force these coals down between the second
                                                            row of coals and the top of the back board.

                12                                                               INSTALLATION & OPERATING INSTRUCTIONS
                                             PILOT BURNER                 STOP LUGS              BURNER STRIP




                                                                                                                                              EXTRA NOTE



                                                                 FRONT CERAMIC PIECES



                                                                                                 DELUXE GAS BURNERS
                                                                                                 CARE SHOULD BE TAKEN
                                                                                                 WHEN HANDLING THE
                                                                                                 CERAMICS
                                                                                                 When assembling the ceramics on the
                                                                                                 Deluxe Burner it is important to make
                                                                                                                                                           550, 700 & 850 GAS CONVECTOR




                                                                                                 sure that pieces of ceramic are fitted
                                                                                                 properly. The 2 pieces of ceramic that




INSTALLATION & OPERATING INSTRUCTIONS
                                                                                                 go onto the front ceramic support tray
                                                                                                 should be behind the stop lugs, not on
                                                                                                 top or pushed down onto the lugs. If
                                                                                                 these ceramics do not fit then a fine file
                                                                                                 should be used across the whole of the
                                                BACK ELEVATION                 FRONT ELEVATION
                                                                                                 front edge of the ceramic pieces until
                                                                                                 enough has been filed away so that they
                                                                                                 lay flat on the base of the front ceramic
                                                    CERAMIC SIDE CHEECK                          support tray and behind the stop lugs.
                                                                                                 The same process should take place with
                                                                                                                                                           INSTALLATION & OPERATING INSTRUCTIONS




                                                                                                 the two side cheeks. If they do not fit
                                                                                                 then the outside edge of both ceramic
                                                                                                 side cheeks should be filed down until
                                                                                                 they fit correctly.




13
                                        550, 700 & 850 DE LUXE
                                        INSTALLATION AND OPERATING INSTRUCTIONS:
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS

                                              12. Commissioning the Fire                 Allow to warm up for 5 minutes and
                                                                                         then using a smoke match or joss stick
                                              Connect a suitable pressure gauge to       set 25mm down and 25mm inside of the
                                              the pressure test point. Light the fire    fire opening run the match across the
                                              on maximum as described in the “User’s     width of the opening to check that all
                                              Instructions”. Check that the setting      of the smoke is drawn away. Some small
                                              pressure is in accordance with that        whiffs of smoke may be expelled from
                                              given on the Chart in the “Technical       the extreme ends of the fire opening
                                              Data” Section or on the Data Label         and this is quite normal.
                                              found in the appliance. Adjust the
                                              Natural Gas or Propane Regulator as        Repeat the test with doors and windows
                                              necessary. After this has been checked     to the premises open and closed, and
                                              shut down the gas fire.                    with any extractor fans in the same room
                                                                                         or adjacent rooms running on high. The
                                              Temporarily isolate the fire from the      fire should continue to clear its
                                              mains supply. Then disconnect the          combustion products. Also operate any
                                              pressure gauge, replace the pressure       other flued appliances in the same or
                                              test point sealing screw, reinstate the    neighbouring rooms and ensure they
                                              mains supply and test for gas soundness.   continue to function satisfactorily as
                                                                                         multiple flues can work against one
                                              Turn the control knob and light the        another.
                                              pilot as described in the “User
                                              Instructions”. Turn the control knob to    If spillage is detected during this
                                              the maximum position and fit the ash       procedure it could indicate a faulty flue
                                              pan cover. Check that after ten minutes    or lack of ventilation. If the problem
                                              all the products of combustion are         cannot be rectified immediately,
                                              entering the flue by traversing the        disconnect the appliance, and advise the
                                              perimeter of the fireplace opening or      customer not to use the appliance until
                                              canopy by using a smoke generator e.g.     the problem has been resolved.
                                              smoke match.
                                                                                         The customer should always be advised
                                              Once the fire is installed and             of the need for regular servicing and
                                              opperational the installer must check      checks to ensure the continued clearance
                                              for spillage. Carry out the lighting       of combustion products.
                                              procedure and turn the fire to high.




                14                                                       INSTALLATION & OPERATING INSTRUCTIONS
550, 700 & 850 GAS CONVECTOR




                                                                                              550, 700 & 850 DE LUXE
                                                                                              INSTALLATION AND OPERATING INSTRUCTIONS:
INSTALLATION & OPERATING INSTRUCTIONS

User’s Instructions                           Warning Notes
13. General                                   Properly installed and operated this
                                              appliance will not leak gases. Persistent
This fire is intended for decorative          fume emission must not be tolerated. If
purposes. Any purpose provided                fume emission does exist, then the
ventilation should be checked regularly       following steps should be taken:
to ensure that it is free from obstruction.
This fire should be serviced regularly by     1   Open doors and windows to ventilate
a qualified person.                               room.

It is recommended that a guard be used        2   Turn the fire off.
for the protection of young children, the
elderly or infirm. A vacuum cleaner may       3   Check for flue blockage and clear if
be used to clean the appliance.                   necessary.
DO NOT throw rubbish etc. upon the            4   Do not attempt to re-light the gas
coals or otherwise disturb the fuel bed.          grate until the cause of the emission
Debris from any source or soot formed             has been identified and rectified. Should
should be removed from time to time.              assistance or advice be required
See “Cleaning Instructions”.                      contact your nearest agent.

The pilot light and flame sensing device
fitted to this fire is also an atmospheric
sensing device which shuts off both the
main burner and pilot if evacuation of the
combustion products is interrupted. If
the fire shuts itself off, do not
use the fire and have the flue and
fire checked by a qualified person.

Due to the newness of materials the fire
may give off a slight smell for a period of
time after commissioning. This is quite
normal and any odour should disperse
after a few hours operation.




 INSTALLATION & OPERATING INSTRUCTIONS                                                        15
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS

                                              14. Lighting the Fire: 550 & 700                To turn off the main burner, turn the
                                              Gas Convector                                   control to MIN - press the knob gently
                                                                                              until it will turn clockwise to the pilot
                                              The positions of the control valve are          position.To turn off the pilot press knob
                                              depicted on the control panel fitted            and turn to off.
                                              around the control knob.
                                                                                              If burnback occurs underneath the
                                              If the main burner or pilot light are           burner, turn knob to the off position.
                                              extinguished for any reason do not              Then re-light the fire. If this problem re-
                                              attempt to re-light the pilot within three      occurs switch off unit and call your gas
                                              minutes.                                        installer.

                                              The off position is self explanatory -          Thus the sequence is:
                                              preventing any gas from passing through
                                              the control valve to either the pilot burner    A. To Light the Fire
                                              or to the main burner.
                                                                                              1   From off press the control knob in
                                              By pressing the control knob in it is               and turn slowly anti-clockwise.
                                              possible to turn it anti-clockwise.The first
                                              function is to turn on the gas to the pilot,    2   When the ignition click occurs,
                                              this occurs just before reaching the pilot          check that the pilot is lit (if not
                                              position. (If the fire has not been lit for         repeat 1 & 2).
                                              some time it may be necessary to hold
                                              the knob in this position for some seconds      3   Hold knob in for 10 - 20 seconds.
                                              to clear the air from the pipe and allow
                                              gas to reach the pilot burner). Once gas        4   Release knob and check pilot
                                              is available at the pilot, continual rotation       remains alight.
                                              anti-clockwise will cause the piezo ignitor
                                              to spark. This is accompanied by a click        5   Turn knob until pointer is horizontal.
                                              at the valve, and should result in the pilot        The fire should then ignite.
                                              burner igniting.This should be verified by
                                              looking at the left-hand side of the fire       6   Let fire fully cross ignite and allow
                                              tray, behind the front coal piece.                  ap p rox i m a t e ly 1 5 s e c o n d s .
                                              Once the pilot is lit the control knob          7   Adjust flames to required level
                                              should continue to be pressed in for 10             without pressing knob.
                                              - 20 seconds. In this time the pilot flame
                                              will have heated the flame supervision          B . To Extinguish the Fire
                                              thermocouple sufficiently to operate a
                                              hold on magnet within the valve.The knob        1   Turn control knob clockwise to
                                              should then be turned so that the pointer           minimum position.
                                              is approximately horizontal. This allows
                                              gas at a low rate to enter the burner and       2   Press knob gently until able to
                                              be ignited by the pilot flame. Once the             continue turning clockwise to pilot.
                                              fire has fully cross lit, allow approximately
                                              15 seconds at this setting to allow the         3   To extinguish the pilot, press knob
                                              flame to fully establish before setting to          and turn to off, although it is in order
                                              any level between Maximum and Minimum               to leave the pilot permanently lit.
                                              by adjusting the control knob accordingly.


                16                                                           INSTALLATION & OPERATING INSTRUCTIONS
550, 700 & 850 GAS CONVECTOR




                                                                                                550, 700 & 850 DE LUXE
                                                                                                INSTALLATION AND OPERATING INSTRUCTIONS:
INSTALLATION & OPERATING INSTRUCTIONS

15. Lighting the Fire: 850 Gas                      MINIMUM FLAME POSITION (Fig.
Convector                                           2C) is opposite the indicating arrow.
                                                    The burner will then ignite .
A. Commissioning the Fire                       3   Turn the control knob to MAXIMUM
The gas control knob is marked with                 FLAME POSITION (Fig. 2D).
positions of OFF • PILOT º MINIMUM ¢            4   Check setting pressure on the inlet
MAXIMUM Æ gas rate. The position                    pressure test point at the maximum
selected should be placed opposite the              rate (LPG 2.75 kPa).
indicating arrow. The gas control valve is      5   Depress and turn the gas control
fitted with a piezo spark ignition.                 knob clockwise until the PILOT
WARNING: If the main burner or pilot                POSITION (Fig. 2B) is opposite the
are extinguished for any reason, you will           indicating arrow. The fire will go out
not be able to re-light the pilot for three         and the pilot will remain lit. Remove
minutes.As there is a further safety feature        the gauge from the pressure test point
into the control valve do not force the             and refit the pressure test point sealing
control knob on the valve.                          screw.
                                                6   Turn the fire on and check for gas
B. To Light the Pilot                               soundness.
1 Ensure that the gas is turned on.             7   Refit the air inlet grill.
2 Ensure that the gas control knob is
   in the OFF POSITION (Fig. 2A).               D. To Turn the Fire Off
3 Slightly depress the gas control knob         1 Remove the air inlet grill.
   and turn anti-clockwise until the            2 Turn the gas control knob clockwise
   PILOT POSITION                                  to the MINIMUM GAS RATE (Fig,
   (Fig. 2B) is opposite the indicating            2C) position, slightly depress the knob
   arrow.                                          and continue turning to the PILOT
4 Push the control knob fully in, and              POSITION.
   with it held in position, fully depress         The fire will go out and the pilot will
   and push the end button on the piezo            remain lit and may be left on
   spark ignitor and the pilot should light.       permanently.
   If the pilot has not lit, repeat the         3 Replace air inlet grill.
   operation.
5 Once the pilot is lit, continue and hold
   in the gas control knob for a further
   10 -15 seconds to establish the pilot.
   If the pilot fails to remain alight repeat
   the procedure, but hold the gas
   control knob in for longer to allow
   the pilot to establish.
C. To Light the Fire
1 If the pilot is not already alight, light
   the pilot as described in B.
2 Slightly depress the gas control knob
   and turn anti-clockwise until the




  INSTALLATION & OPERATING INSTRUCTIONS                                                         17
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS

                                              E. To Turn the Fire and Pilot Off                        1 6 . C l e a n i n g I n s t ru c t i o n s
                                              1 Remove the air inlet grill.
                                              2 Turn the fire off as described in No.                  NOTE: Due to the ceramic fibre material
                                                 3 Depress the control knob.                           used in the fuel bed it is inevitable that
                                              3 Turn to the OFF POSITION and the                       cleaning/replacement can be a dirty and
                                                 pilot will go out.                                    dusty operation. Suitable precautions should
                                              4 Replace the air inlet grill.                           be taken. Due to the intense temperatures
                                                                                                       reached in the fire some surface cracks may
                                              Safety Feature: If the pilot is turned                   appear on the ceramic components. This is
                                              off you will not be able to re-ignite the pilot          quite normal and will not affect the safe
                                              for a minimum of 30 seconds.                             operation of the appliance.

                                                                                                       1 Turn off the fire and allow it to go
                                                                                                         cold.
                                                                                                       2 Carefully remove all the coals one
                                                                                                         at a time by hand and remove any soot
                                                                                                         deposits with a soft brush.
                                                                                                       3 Remove any debris etc., from the back
                                                                                                         board. A vacuum cleaner may be used
                                                                                                         with care.
                                                                                                       4 Carefully reposition or renew the
                                                                                                         coals as described in “Positioning the
                                                                                                         coals”.
                                                                                                       5 Do not add any additional logs or
                                                                                                         coals.




                                                                                                                    Figure 2A         Figure 2B
                                                                                                                       OFF              PILOT

                                                                                        Switch indicator point




                                               Figure1: A: Outlet pressure test point
                                                        B: Inlet pressure test point
                                                                                                                    Figure 2C        Figure 2D
                                                                                                                    MINIMUM          MAXIMUM




                18                                                             INSTALLATION & OPERATING INSTRUCTIONS
550, 700 & 850 GAS CONVECTOR




                                                                                             550, 700 & 850 DE LUXE
                                                                                             INSTALLATION AND OPERATING INSTRUCTIONS:
INSTALLATION & OPERATING INSTRUCTIONS

SERVICING INSTRUCTIONS

17. General                                      1 8 . S e r v i c i n g P ro c e d u re
The following servicing procedure                1  Turn off fire and allow it to go cold.
should be carried out regularly and              2  Turn off gas supply at the isolation
only by a qualified person.                         tap.
                                                 3 Carefully remove all the coals and
NOTE: Due to the materials used in                  ceramics one at a time by hand and
the fuel bed, it is inevitable that                 remove any soot deposits by hand
servicing can be a dirty and dusty                  with a soft brush i.e. paint brush.
operation. Suitable precautions should              NOTE: Due to the intense
be taken.                                           temperatures reached in the fire
                                                    some surface cracks may appear
Important: The pilot and flue sensing               on the ceramic components. This
device fitted to this fire is also an               is quite normal and will not affect
atmospheric sensing device. If for any              the safe operation of the appliance.
reason any part of the pilot assembly            4 Disconnect the gas pipe from the
is to be replaced the entire assembly               valve and lift the gas grate out of
i n c l u d i n g t h e p i l o t b u r n e r,      the fire box.
thermocouple electrode and injector              5 Remove the injectors then clean
must be exchanged complete for a                    and visually inspect for damage
pilot assembly from the original                    before replacing.
manufacturer only. This atmosphere               6 Clean the burner tray and flame
sensing device is not adjustable and                strip.
must not be put out of action.                   7 Visually inspect the gas grate for
                                                    any defects before replacing.
                                                 8 Re-assemble in reverse order,
                                                    reconnect to gas supply and check
                                                    for gas soundness.
                                                 9 Replace all ceramics and coals as
                                                    described in “Positioning the Coals”.
                                                 10 Check that any purpose provided
                                                    ventilation is free from obstruction.
                                                 11 Re-commission the fire as described
                                                    in “Commissioning the Fire”.
                                                 19. Registering the Warranty
                                                 Jetmaster warrants the Gas Grate for
                                                 one year, providing it is fitted and used
                                                 correctly, and has been fitted by a
                                                 registered LPGAS Association fitter
                                                 accredited by Jetmaster, and the
                                                 Warranty Card is returned to Jetmaster
                                                 fully completed, including the fitter’s
                                                 details and telephone contact number,
                                                 within 30 days of purchase.


INSTALLATION & OPERATING INSTRUCTIONS                                                        19
INSTALLATION AND OPERATING INSTRUCTIONS:      550, 700 & 850 GAS CONVECTOR
                     550, 700 & 850 DE LUXE   INSTALLATION & OPERATING INSTRUCTIONS

                                              20. Repairs under Warranty                     22. Gas Fumes
                                              (This work can only be carried out by a
                                              person who is a registered LPGAS               Occasional fumes from cross-draughts
                                              Association installer.)                        may occur but persistent fume emission
                                                                                             must not be tolerated. If this occurs, if you
                                              Most problems are minor and can be             smell gas, or if you feel drowsy or have a
                                              solved by the fitter, and it is a condition    head-ache when the Gas Grate is burning,
                                              of the Warranty that in the first instance     the following immediate actions must be
                                              the customer contacts the Distributor          taken:
                                              from whom the fire was purchased and
                                              arranges for the same fitter to return to      1   Turn off the Gas Grate and extinguish
                                              try to remedy the problem. If necessary,           all naked flames.
                                              the fitter can telephone the Jetmaster         2   Open doors and windows to ventilate
                                              Technical Help Telephone Line on (011)             room.
                                              474-2100 from site and get advice. In the      3   Turn the gas off at the gas cylinder.
                                              unlikely event that this fails to cure the     4   Check for flue and ventilator blockage
                                              problem, Jetmaster will organise for               and clean if required.
                                              technical assistance on site. In this case     5   Do not attempt to re-light the Gas
                                              Jetmaster requires that the original fitter        Grate until the cause of fume emission
                                              also attends. The Jetmaster Warranty is            has been identified and rectified. If
                                              only effective if the Gas Grate is installed       necessary seek professional advice
                                              fully in accordance with these instructions        from Jetmaster (Pty) Ltd telephone
                                              and the Warranty Card is returned fully            (011) 474-2100 or a registered LPGAS
                                              completed within 30 days of purchase.              Association installer.
                                              The fitter must fill in his details of the
                                              Warranty Card.

                                              21. Maintaining the Gas Grate
                                              Gas fires need checking annually. This
                                              involves cleaning and relaying the coals,
                                              checking the pilot light and all joints,
                                              checking ventilators and fume clearance,
                                              and repainting the exposed parts. It should
                                              take an hour to an hour and a half. We
                                              are a seasonal business - so please do not
                                              leave calling us for a maintenance visit
                                              until the first day of winter!
                                              Book ahead! Keep a service book on until.




                20                                                           INSTALLATION & OPERATING INSTRUCTIONS
We would like to thank you for purchasing one of our gas fireplaces

1   Jetmaster warrants that the burner and controls of this Gas Grate or Gas Convector
    will be free from defects in workmanship or materials under normal use and service
    for a period of one year from the invoiced date of purchase.

2   Jetmaster warrants that the Gas Convector firebox will be free from defects in
    workmanship or materials under normal use and service for a period of ten years
    from the invoiced date of purchase. This Warranty does not cover rust as all units
    are made of mild steel.

3   This warranty is only effective if:

    3.1   At the time of the claim the then owner of the Gas Grate/Gas Convector
          burner and/or firebox produces documentary evidence to prove the date
          of purchase, e.g. the original or true copy of the invoice.

    3.2   The Warranty Card (supplied separately) was fully completed and returned
          to Jetmaster by main or by fax within 30 days of purchase.

    3.3    The Gas Grate/Gas Convector burner and/or firebox was installed by a
          registered LPGAS Association fitter and was purchased from an appointed
          Jetmaster Agent.

    3.4   The installation, operation and maintenance of the Gas Grate/Gas Convector
          burner and/or firebox was, in the opinion of Jetmaster, carried out in
          accordance with the Installation and Operating Instructions current at the
          time of purchase and no modifications have been made to the product
          without written authority.

4   When a valid claim arises under this Warranty, Jetmaster will, as its sole option,
    either repair or replace the Gas Grate/Gas Convector burner and/or firebox,
    having firstly been investigated by the appointed Distributor of Jetmaster.

5    Under no circumstances will Jetmaster be liable for any consequential loss or
    damage or injury arising out of, or in connection with, the use or operation of the
    Gas Grate/Gas Convector burner and/or firebox resulting from the failure to
    follow the Installation and Operating Instructions, or from a breach of the Warranty
    conditions.
                          Jetmaster (Pty) Ltd.
                             PO BOX 43178, Industria 2042

                            SOUTH AFRICA
                      0800005858 (Toll-free no.)

Gauteng (Johannesburg):                    Cape Town:
1316 Clubhouse Street                      Cnr. Koeberg Road and School Street
Maraisburg, Johannesburg                   Milnerton
Tel: (011) 661 5900                        Tel: (021) 552 0808
Fax: (011) 474 2144                        Fax: (021) 552 0810

Gauteng (Pretoria):                        Mpumalanga:
Menlyn Shopping Centre.                    10 Milli Street
Shop LF 8/9                                Middelburg
Pretoria                                   Mpumalanga
Tel : (012) 348 7741                       Tel: (013) 246 2600
Fax: (012) 348 7972                        Fax: (013) 246 2951

Port Elizabeth:                            Richards Bay:
130 Burman Road                            63 Kabel Kring Road
Deal Party                                 Alton,
Tel: (041) 486 1471                        Richardsbay
Fax: (041) 486 1409                        Tel: (035) 797 5800
                                           Fax: (035) 797 5818
East London:
3 Nottingham Road                          Durban:
Gately                                     Cnr. Meridian & Solstice roads
East London                                Umhlanga Ridge
Tel: (043) 731 1246                        Tel: (031) 566 2252
Fax: (043) 731 1268                        Fax: (031) 566 2632



                          www.jetmaster.co.za

				